Skip to main content

Full text of "National Voluntary Laboratory Accreditation Program 1999 directory"

See other formats


NAT 


L  INST.  OF  STAND  &  TECH  R IX. 


A11105  bllQlb 


NISI 
PUBLICATIONS 


National 

Voluntary 

Laboratory 

Accreditation 

Program 


1999 

Directory 


QC 

100 

U57 

NO. 810 
1999 


f\J|G^T"  Special  Publication  810, 


1999  edition 


U.S.  Department  of  Commerce 

Technology  Administration 
National  Institute  of  Standards 
and  Technology 


UNITED  STATES  DEPARTMENT  OF  COMMERCE 

National  Institute  of  Standards  and  Technology 

Gaithersburg,  Maryland  20899-0001 


Dear  Colleague: 

NVLAP  has  made  tremendous  stndes  in  achieving  its  goal  to  be  recognized  nationally  and 
internationally  as  a  "world-class"  laboratory  accreditation  organization.  After  in-depth  evaluations 
conducted  of  the  NVLAP  operations  by  representatives  of  the  Asia  Pacific  Laboratory  Accreditation 
Cooperation  (APLAC),  NVLAP  signed  the  APLAC  Mutual  Recognition  Arrangement  (MRA)  in 
Tokyo  in  November  1997.  Other  signatories  to  the  MRA  included  accrediting  bodies  from  Australia 
(NATA),  New  Zealand  (IANZ),  Hong  Kong  (HOKLAS),  Singapore  (SAC-SINGLAS),  and  Taiwan 
(CNLA).  Since  that  time,  NVLAP  personnel  have  participated  as  members  of  multinational  teams  that 
have  evaluated  the  accrediting  bodies  in  Japan  (JAB,  JNLA)  and  Korea  (KOLAS),  and  those  bodies 
have  since  been  added  to  the  MRA.  This  has  implications  for  reducing  technical  barriers  to  trade 
among  the  MRA  partners  since  the  signatories  recognize  the  test  reports  and  calibration  certificates 
issued  by  their  accredited  laboratories  as  being  technically  equivalent. 

NVLAP  received  the  final  assessment  from  the  European  Cooperation  for  Accreditation  (EA)  in 
September  1998.  As  of  the  publication  of  this  Directory,  we  have  responded  to  the  EA  evaluation 
report  and  are  awaiting  a  favorable  decision  as  to  the  admission  of  NVLAP  to  the  EA  recognition 
agreement.  Like  the  APLAC  MRA,  the  EA  agreement  will  open  up  trade  avenues  and  reduce 
technical  barriers  to  trade  by  promoting  the  recognition  and  acceptance  of  accredited  laboratories' 
certificates  and  reports. 

NVLAP  continues  to  work  within  the  umbrella  of  the  North  American  Free  Trade  Agreement 
(NAFTA)  with  Canada  and  Mexico  to  reach  a  point  of  mutual  recognition  between  the  calibration 
laboratory  accreditation  bodies  in  each  country.  This  is  being  done  under  a  Memorandum  of 
Understanding  between  the  national  measurement  laboratories  and  their  closely  affiliated  calibration 
laboratory  accreditation  bodies,  which  established  the  North  American  Calibration  Cooperation 
(NACC).  NACC  meets  regularly  to  discuss  recognition  issues,  to  share  quality  documentation,  and  to 
plan  cross-border  interlaboratory  comparisons  (ILCs)  involving  samplings  of  calibration  laboratories  in 
each  country.  The  first  ILC  in  resistance  is  nearing  completion  with  more  planned  this  year  in  mass, 
length,  temperature,  and  electrical  measurements. 

NVLAP  is  working  towards  continuous  process  improvement  in  the  accreditation  programs  that  it 
offers  to  its  constituency  of  over  eight  hundred  testing  and  calibration  laboratories.  We  look  forward 
to  working  with  our  old  friends  and  new  ones  in  the  coming  year.  Please  let  us  know  how  we  are 
serving  you.  We  factor  all  comments,  good  and  bad,  into  our  process  in  an  attempt  to  maintain  good 
customer  relations  and  to  improve  our  services  wherever  possible. 


Sincerely, 


Laboratory  Accreditation  Program 


Nisr 


NIST  Special  Publication  810, 
1999  edition 


National 

Voluntary 

Laboratory 

Accreditation 

Program 


1999 

Directory 


Vanda  R.  White,  Editor 
March  1999 

Supersedes  SP  810,  1998  edition 


U.S.  Department  of  Commerce 

William  M.  Daley,  Secretary 

Technology  Administration 

Gary  R.  Bachula,  Acting  Under  Secretary  for 

Technology 

National  Institute  of  Standards  and  Technology 
Raymond  G.  Kammer,  Director 


National  Institute  of  Standards  and  Technology 
Special  Publication  810 
Supersedes  SP  810,  1998  edition 
364  pages  (March  1999) 
CODEN:  NSPUE2 


U.S.  GOVERNMENT  PRINTING  OFFICE 
WASHINGTON:  1999 


For  sale  by  the  Superintendent  of  Documents 
U.S.  Government  Printing  Office 
Washington,  DC  20402-9325 


NVLAP  AND  THE  NVLAP  LOGO 

The  term  NVLAP  and  the  NVLAP  logo  are 
Federally  registered  trademarks  of  the  National 
Institute  of  Standards  and  Technology  and  the 
Federal  Government,  who  retain  exclusive  rights 
therein.  Permission  to  use  the  term  and/or  the  logo 
is  granted  to  NVLAP-accredited  laboratories  for  the 
limited  purposes  of  announcing  their  accredited 
status,  and  for  use  on  reports  that  describe  only 
testing  and  calibration  within  the  scope  of 
accreditation.  NIST  reserves  the  right  to  control 
the  quality  of  the  use  of  the  term  NVLAP  and  of 
the  logo  itself. 


INTRODUCTION 


The  laboratories  listed  in  this  Directory  have  been  found  to  be  competent  to  perform  certain  tests  or 
calibrations  as  specified.  These  laboratories  are  allowed  to  use  the  NVLAP  logo  on  their  test  or 
calibration  certificates  or  reports,  which  implies  that  the  processes  used  to  achieve  the  tests  or  calibrations 
have  been  evaluated  by  NVLAP  as  being  technically  adequate  when  performed  under  the  conditions 
specified  in  the  laboratories'  quality  manuals  and  associated  documentation.  Further,  NVLAP  certifies 
that  the  laboratories  have  demonstrated  traceability  of  their  tests  or  calibrations  to  national  standards  at 
the  appropriate  levels  of  uncertainty  for  which  the  laboratories  have  been  accredited. 

As  a  prospective  customer  of  the  laboratories  listed  in  this  Directory,  you  should  be  aware  that  the 
laboratories  are  obligated  to  inform  you,  before  the  fact,  whenever  a  test  or  a  calibration  service  which 
you  have  requested  is  not  covered  by  the  NVLAP  accreditation  (NIST  Handbook  150,  Section 
285.33(k)(8)).  When  contracting  for  the  test  or  calibration  service,  you  have  the  right  to  specify  whether 
or  not  you  desire  a  NVLAP-accredited  test  or  calibration.  Provision  of  a  non-NVLAP-accredited  test  or 
calibration  shall  not  be  accompanied  by  the  use  of  the  NVLAP  logo  on  the  certificate  or  report,  and 
NVLAP  does  not  endorse  any  claims  made  regarding  traceability  and  uncertainty  of  the  measurements 
performed. 

In  addition,  if  a  laboratory  performs  a  combination  of  tests  or  calibrations,  some  of  which  have  been 
accredited  by  NVLAP  and  some  of  which  have  not,  the  laboratory  is  bound  by  the  provisions  of  NIST 
Handbook  150  to  clearly  identify  the  tests  or  calibrations  covered  by  NVLAP  accreditation  and  those  not 
accredited  by  NVLAP  on  the  test  or  calibration  certificate  or  report. 

Current  information  on  the  accreditation  status  of  a  laboratory  can  be  obtained  by  contacting  NVLAP  as 
follows: 

(1)  Address:     Chief,  Laboratory  Accreditation  Program 

National  Institute  of  Standards  and  Technology 
100  Bureau  Drive,  Stop  2140 
Gaithersburg,  MD  20899-2140; 

(2)  Phone:  (301)  975-4016; 

(3)  Fax:  (301)  926-2884;  or 

(4)  E-mail:  nvlap@nist.gov. 

NVLAP  also  maintains  a  directory  of  accredited  laboratories  on  the  Internet,  which  is  updated  quarterly. 
The  URL  for  NVLAP's  home  page  is  http://ts.nist.gov/nvlap. 


iii 


i 


CONTENTS 


Page 

INTRODUCTION    iii 

PROGRAM  SUMMARY   1 

LABORATORY  ACCREDITATION  SUMMARY    6 

HOW  TO  USE  THIS  DIRECTORY   7 

INDEX  A.  LISTING  BY  LABORATORY  NAME   Al 

INDEX  B.  LISTING  BY  FIELD  OF  ACCREDITATION    Bl 

CALIBRATION  LABORATORIES  GROUP   B3 

Dimensional    B3 

Electromagnetics  -  DC/Low  Frequency    B3 

Electromagnetics  -  RF/Microwave    B3 

Ionizing  Radiation    B3 

Mechanical   B3 

Optical  Radiation   B4 

Thermodynamic   B4 

Time  and  Frequency   B4 

COMPUTER/ELECTRONICS  GROUP   B4 

Cryptographic  Modules  Testing   B4 

GOSIP   B4 

Federal  Communications  Commission  (FCC)  Methods   B4 

MIL-STD-462  Test  Methods   B8 

DOSIMETRY  GROUP    B8 

Ionizing  Radiation  Dosimetry    B8 

ENVIRONMENTAL  GROUP   BIO 

Asbestos  Fiber  Analysis  (PLM  Test  Method)   BIO 

Asbestos  Fiber  Analysis  (TEM  Test  Method)   B16 

FASTENERS  AND  METALS  GROUP   B18 

PRODUCT  TESTING  GROUP   B20 

Acoustical  Testing  Services   B20 

Carpet  and  Carpet  Cushion   B21 

Commercial  Products  Testing   B21 

Construction  Materials  Testing   B21 

Efficiency  of  Electric  Motors   B22 

Energy  Efficient  Lighting  Products   B22 

Thermal  Insulation  Materials   B22 

Wood  Based  Products    B23 

INDEX  C.  LISTING  BY  STATE/COUNTRY    CI 

INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE   Dl 

INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE    El 


v 


• 


PROGRAM  SUMMARY 


The  National  Institute  of  Standards  and  Technology  (NIST)  administers  the  National  Voluntary 
Laboratory  Accreditation  Program  (NVLAP).  NVLAP  is  comprised  of  a  series  of  laboratory 
accreditation  programs  (LAPs)  which  are  established  on  the  basis  of  requests  and  demonstrated  need. 
Each  LAP  includes  specific  calibration  and/or  test  standards  and  related  methods  and  protocols  assembled 
to  satisfy  the  unique  needs  for  accreditation  in  a  field  of  testing  or  calibration.  NVLAP  accredits  public 
and  private  laboratories  based  on  evaluation  of  their  technical  qualifications  and  competence  to  carry  out 
specific  calibrations  or  tests.  Accreditation  criteria  are  published  in  the  Code  of  Federal  Regulations 
(Title  15,  Part  285)  as  a  part  of  the  NVLAP  Procedures  and  General  Requirements,  and  encompass  the 
requirements  of  ISO/IEC  Guide  25  and  the  relevant  requirements  of  ISO  9002.  Accreditation  is  granted 
following  successful  completion  of  a  process  which  includes  submission  of  an  application  and  payment 
of  fees  by  the  laboratory,  an  on-site  assessment,  resolution  of  any  deficiencies  identified  during  the  on-site 
assessment,  participation  in  proficiency  testing,  and  technical  evaluation.  The  accreditation  is  formalized 
through  issuance  of  a  Certificate  of  Accreditation  and  Scope  of  Accreditation  (fig.  1)  and  publicized  by 
announcement  in  various  government  and  private  media. 

NVLAP  accreditation  is  available  to  commercial  laboratories;  manufacturers'  in-house  laboratories; 
university  laboratories;  and  federal,  state,  and  local  government  laboratories.  Foreign-based  laboratories 
may  also  be  accredited  if  they  meet  the  same  requirements  as  domestic  laboratories  and  pay  any  additional 
fees  required  for  travel  expenses. 

NVLAP  provides  an  unbiased  third  party  evaluation  and  recognition  of  performance,  as  well  as  expert 
technical  guidance  to  upgrade  laboratory  performance.  NVLAP  accreditation  signifies  that  a  laboratory 
has  demonstrated  that  it  operates  in  accordance  with  NVLAP  requirements  in  the  following  areas: 
accommodation  and  environment;  calibration  and  test  methods;  certificates  and  reports;  complaints; 
equipment  and  reference  materials;  handling  of  calibration  and  test  items;  measurement  traceability  and 
calibration;  organization  and  management;  outside  support  services  and  supplies;  personnel;  quality 
system,  audit  and  review;  records;  and  subcontracting.  NVLAP  accreditation  does  not  imply  any 
guarantee  (certification)  of  laboratory  performance  or  test/calibration  data;  it  is  solely  a  finding  of 
laboratory  competence.  A  laboratory  may  cite  its  accredited  status  and  use  the  NVLAP  logo  on  reports, 
stationery,  and  in  business  and  trade  publications  provided  that  this  use  does  not  imply  product 
certification. 

This  Directory  of  laboratories  is  published  annually  and  lists  the  name,  address,  contact  person,  phone 
and  fax  numbers,  e-mail  and  URL  addresses  (if  available),  accreditation  renewal  date,  and  scope  of 
accreditation  for  each  laboratory.  An  updated  listing  of  laboratories  is  published  quarterly  on  NVLAP's 
home  page  on  the  Internet:  http://ts.nist.gov/nvlap. 

Accreditation  Renewal  Date 

A  laboratory  accreditation  is  valid  for  one  year  and  commences  on  one  of  four  dates:  January  1,  April  1, 
July  1,  or  October  1;  an  accreditation  will  terminate  after  one  year  unless  renewed  by  the  laboratory. 
Users  of  this  Directory  who  are  considering  selection  of  accredited  laboratories  should  be  aware  of  the 
renewal  date  and  verify  that  the  laboratory  has  retained  its  accreditation  at  the  time  its  services  are  to  be 
provided.  Verification  of  accreditation  status  can  be  obtained  by  contacting  NVLAP. 


1 


On-Site  Assessment 


Before  initial  accreditation,  an  on-site  assessment  of  each  laboratory  is  conducted  to  determine  compliance 
with  the  NVLAP  criteria.  After  accreditation  is  granted,  an  on-site  assessment  must  be  conducted  every 
two  years  in  order  for  the  laboratory  to  maintain  accreditation.  An  assessment  is  conducted  by  one  or 
more  NVLAP  assessors  selected  on  the  basis  of  their  expertise  in  the  field  of  testing  or  calibration  to  be 
reviewed.  They  may  be  engineers  or  scientists  currently  active  in  the  field,  consultants,  college 
professors  or  retired  persons.  Their  services  are  generally  contracted  as  required. 

Assessors  use  checklists  provided  by  NVLAP  so  that  each  laboratory  receives  an  assessment  comparable 
to  that  received  by  others.  However,  assessors  have  some  latitude  to  make  judgments  about  a 
laboratory's  compliance  with  the  NVLAP  criteria. 

An  assessment  normally  takes  one  to  five  days  depending  on  the  extent  of  the  laboratory's  application. 
Every  effort  is  made  to  conduct  an  assessment  with  as  little  disruption  as  possible  to  the  normal 
operations  of  the  laboratory.  During  the  assessment,  the  assessor  carries  out  the  following  functions: 

-  meets  with  management  and  supervisory  personnel  responsible  for  the  laboratory's  activities  to 
review  the  assessment  process  and  to  set  the  assessment  agenda; 

-  examines  the  laboratory's  quality  assurance  system,  selects  and  traces  the  history  of  one  or  more 
samples  from  receipt  to  final  issuance  of  reports,  conducts  a  thorough  review  of  the  laboratory's 
quality  manual,  evaluates  the  training  program,  examines  notebooks  or  records  pertaining  to  the 
samples,  checks  sample  identification  and  tracking  procedures,  determines  whether  the  appropriate 
environmental  conditions  are  maintained,  and  examines  copies  of  completed  reports; 

-  reviews  records  of  periodic  internal  audits,  use  of  check  samples  or  participation  in  round-robin 
testing  or  other  similar  programs,  personnel  records  including  resumes  and  job  descriptions  of  key 
personnel,  competency  evaluations  for  all  staff  members  who  routinely  perform  the  testing  or 
calibration  for  which  accreditation  is  sought,  calibration  or  verification  records  for  apparatus  used, 
reports,  and  sample  control  records; 

-  observes  demonstrations  of  laboratory  techniques  and  discusses  them  with  the  technical  personnel 
to  assure  their  understanding  of  the  procedures;  and 

-  examines  major  equipment,  apparatus,  and  facilities. 

At  the  conclusion  of  the  assessment,  the  assessor  will  conduct  an  exit  briefing  to  discuss  observations  and 
any  deficiencies  with  responsible  laboratory  staff.  A  written  assessment  report  will  be  left  with  the 
laboratory,  and  a  copy  forwarded  to  NVLAP. 

If  the  on-site  inspection  reveals  deficiencies  that  pertain  to  NVLAP  requirements,  the  laboratory  must 
respond  in  writing  to  NVLAP  within  30  days  of  such  notification.  The  response  must  provide 
documentation,  signed  by  the  Authorized  Representative,  that  the  specified  deficiencies  have  either  been 
corrected  or  include  a  plan  of  action  to  make  corrections. 


2 


Monitoring  Visits 

Monitoring  visits  may  be  conducted  at  any  time  during  the  accreditation  period  for  cause  or  on  a  random 
selection  basis.  These  visits  serve  to  verify  reported  changes  in  the  laboratory's  personnel,  facilities,  or 
operations,  or  to  explore  possible  reasons  for  poor  performance  in  proficiency  testing.  The  scope  of  a 
monitoring  visit  may  range  from  checking  a  few  designated  items  to  a  complete  review. 

Proficiency  Testing 

Proficiency  testing  is  an  integral  part  of  the  NVLAP  accreditation  process.  On-site  demonstration  of 
appropriate  facilities,  equipment,  personnel,  etc.,  is  essential,  but  may  not  be  sufficient  for  the  continuing 
evaluation  of  laboratory  competence.  The  production  of  test/calibration  data  using  special  proficiency 
testing  samples  or  artifacts  provides  NVLAP  with  a  means  to  determine  the  overall  competence  of  the 
laboratory.  Information  obtained  from  proficiency  testing  helps  to  identify  problems  in  a  laboratory. 
When  problems  are  found,  NVLAP  works  with  the  laboratory  staff  to  solve  them. 

Most  fields  of  accreditation  have  proficiency  testing  requirements.  Data  submitted  by  the  laboratories 
in  response  to  specific  NVLAP  requirements  are  analyzed  and  reports  of  the  results  are  made  known  to 
the  participants.  Summary  results  are  available  upon  request  to  other  interested  parties;  e.g. ,  professional 
societies  and  standards  writing  bodies.  The  identity  and  performance  of  individual  laboratories  are  kept 
confidential. 

Satisfactory  participation  is  based  on  specially  tailored  exercises  designed  to  evaluate  the  ability  of  the 
laboratory  to  produce  the  services  for  which  it  is  accredited.  Some  methods  define  pass/fail  criteria;  in 
other  cases,  individual  laboratory  results  must  fall  within  statistically  acceptable  limits  of  overall  group 
performance.  In  a  number  of  programs,  NVLAP  requires  satisfactory  participation  in  proficiency  testing 
as  a  condition  of  initial,  as  well  as  continuing,  accreditation. 

Technical  Evaluation 

A  final  technical  evaluation  is  performed  by  a  NVLAP  review  panel.  The  panel's  recommendations 
regarding  accreditation  are  based  on: 

-  information  provided  on  the  application; 

-  results  of  quality  system  documentation  review; 

-  on-site  assessment  reports; 

-  actions  taken  by  the  laboratory  to  correct  deficiencies; 

-  results  of  proficiency  testing;  and 

-  information  from  any  monitoring  visits  of  the  laboratory. 

If  the  technical  evaluation  reveals  additional  deficiencies,  written  notification  of  the  deficiencies  will  be 
sent  to  the  laboratory.  The  laboratory  must  respond  as  specified  in  the  previous  section,  On-Site 
Assessment.  Clarification  of  some  issues  may  be  requested  by  telephone.  All  deficiencies  must  be 
resolved  before  accreditation  can  be  granted. 


3 


Accreditation  Actions 


After  the  technical  evaluation  has  been  completed  and  all  financial  and  administrative  requirements  have 
been  satisfied,  NVLAP  takes  one  of  the  following  accreditation  actions: 

Accreditation    The  laboratory  is  issued  a  Certificate  of  Accreditation  and  a  Scope  of  Accreditation. 

Denial  The  laboratory  is  notified  of  a  proposal  to  deny  accreditation  and  the  reason(s). 

If  an  accredited  laboratory  is  found  to  be  out  of  compliance  with  the  NVLAP  criteria,  NVLAP  may  take 
one  of  the  following  actions: 


Suspension  Suspension  is  a  temporary  removal  of  the  accredited  status  of  a  laboratory  when  it  is 
found  to  be  out  of  compliance  with  the  terms  of  its  accreditation.  The  laboratory  will  be 
notified  of  the  reasons  for  and  conditions  of  the  suspension  and  the  action(s)  that  the 
laboratory  must  take  to  have  the  accreditation  reinstated. 

Reasons  for  suspension  include:  loss  of  key  personnel,  loss  of  major  equipment,  damage 
to  laboratory  by  fire,  changing  laboratory  location,  proficiency  test  failure. 

Revocation  Revocation  is  the  removal  of  the  accredited  status  of  a  laboratory  when  it  is  found  to 
have  violated  the  terms  of  its  accreditation.  The  laboratory  will  be  notified  of  the  reasons 
for  proposed  revocation  and  the  procedure  for  appealing  such  a  decision.  If  accreditation 
is  revoked,  the  laboratory  may  be  given  the  option  of  voluntarily  terminating  the 
accreditation.  A  laboratory  whose  accreditation  has  been  revoked  must  return  its 
Certificate  of  Accreditation  and  cease  use  of  the  NVLAP  logo  on  any  of  its  reports, 
correspondence,  or  advertising. 

Reasons  for  revocation  include:  obtaining  accreditation  through  fraud,  refusal  to  resolve 
deficiencies,  no  longer  providing  the  type  of  calibration  or  testing  service  for  which 
accreditation  was  issued. 

If  denial  or  revocation  has  been  proposed,  the  laboratory  may  appeal  the  decision  to  the  Director  of 
NIST.  If  an  appeal  is  not  requested,  the  action  becomes  final  upon  the  expiration  of  the  30-day  period 
following  receipt  of  the  notification. 


4 


5 


LABORATORY  ACCREDITATION  SUMMARY 


The  following  table  summarizes  laboratory  accreditations  by  field  of  testing  or  calibration  as  of  the  date 
this  Directory  was  prepared  for  publication.  Since  some  laboratories  are  accredited  in  more  than  one 
field,  the  total  number  of  laboratories  listed  by  field  of  accreditation  (see  Index  B)  is  greater  than  the 
number  of  laboratories  in  the  system  (see  Index  A). 


PROGRAM  GROUP '/Field  of  Accreditation  Number  of  Accreditations 


CALIBRATION  LABORATORIES  GROUP 

Dimensional  10 

Electromagnetics  -  DC/Low  Frequency  8 

Electromagnetics  -  RF/Microwave  4 

Ionizing  Radiation  5 

Mechanical  10 

Optical  Radiation  1 

Thermodynamics  7 

Time  and  Frequency  7 

COMPUTER/ELECTRONICS  GROUP 

Cryptographic  Modules  Testing  3 

Federal  Communications  Commission  (FCC)  Methods  155 

GOSIP  2 

MIL-STD-462  Test  Methods  16 

DOSIMETRY  GROUP/Ionizing  Radiation  Dosimetry  44 

ENVIRONMENTAL  GROUP/Asbestos  Fiber  Analysis:    PLM  test  method  311 

TEM  test  method  81 

FASTENERS  AND  METALS  GROUP  90 

PRODUCT  TESTING  GROUP 

Acoustical  Testing  Services  20 

Carpet  and  Carpet  Cushion  13 

Commercial  Products  Testing  7 

(Paints,  Paper,  Plastics,  Plumbing,  Roofing,  Seals/Sealants) 

Construction  Materials  Testing  16 

Efficiency  of  Electric  Motors  7 

Energy  Efficient  Lighting  Products  10 

Thermal  Insulation  Materials  18 

Wood  Based  Products  5 

TOTAL  ACCREDITATIONS  850 


HOW  TO  USE  THIS  DIRECTORY 


The  1999  Directory  lists  laboratories  accredited  by  NVLAP.  It  consists  of  five  indexes  which  are  cross- 
referenced  by  NVLAP  Lab  Code,  a  unique  identifier  assigned  to  each  laboratory;  e.g.,  100000-0.  The 
Directory  enables  the  user  to  locate  name,  address,  telephone  and  accreditation  information  about  laboratories 
of  interest.  The  user  should  contact  the  laboratories  directly  to  get  information  beyond  that  provided  here. 

INDEX  A,  LISTING  BY  LABORATORY  NAME,  lists  all  laboratories  in  alphabetical  order  by  laboratory 
name.  The  name  of  each  laboratory  is  listed  as  it  appears  on  its  application  for  accreditation. 

INDEX  B,  LISTING  BY  FIELD  OF  ACCREDITATION,  lists  all  laboratories  in  alphabetical  order  by 
laboratory  name  within  field  of  accreditation.  The  index  is  organized  by  PROGRAM  GROUPS,  which  are 
groups  of  Laboratory  Accreditation  Programs  (LAPs)  assembled  in  categories  of  technical  fields  for  efficiency 
in  management  (see  page  6).  Listed  under  each  PROGRAM  GROUP  are  the  technical  fields  of  accreditation 
managed  within  that  GROUP.  Laboratories  accredited  in  more  than  one  field  will  have  more  than  one  listing 
in  this  index. 

INDEX  C,  LISTING  BY  STATE/COUNTRY,  lists  all  laboratories  in  alphabetical  order  by  laboratory  name 
within  state.  The  states  are  designated  by  the  standard  two-letter  postal  abbreviations.  Laboratories  located 
outside  of  the  United  States  are  listed  at  the  end  of  the  index.  Index  C  also  indicates  the  field  of  accreditation 
for  each  laboratory. 

INDEX  D,  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE,  lists  all  testing 
laboratories  in  numerical  order  by  NVLAP  Lab  Code.  There  is  only  one  listing  per  Lab  Code  in  Index  D. 

INDEX  E,  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE,  lists  all  calibration 
laboratories  in  numerical  order  by  NVLAP  Lab  Code.  There  is  only  one  listing  per  Lab  Code  in  Index  E. 

INFORMATION  CONTAINED  IN  INDEXES  D  AND  E 

Each  laboratory  receives  a  Certificate  of  Accreditation  and  a  Scope  of  Accreditation  when  accreditation  is 
granted  or  renewed.  The  Scope  of  Accreditation  details  the  methods  and  services  for  which  accreditation  has 
been  granted  to  a  laboratory.  Indexes  D  and  E  present  a  condensation  of  the  Scope(s)  of  Accreditation  for 
testing  and  calibration  laboratories,  respectively. 

The  following  information  is  presented  for  each  laboratory  listed  in  Index  D  or  Index  E: 

(a)  NVLAP  Lab  Code; 

(b)  Laboratory  name  and  address; 

(c)  Authorized  representative  (contact); 

(d)  Phone  number; 

(e)  Fax  number; 

(f)  E-mail  address  (if  available); 

(g)  URL  (web  site)  address  (if  available); 

(h)  Field  of  accreditation; 

(i)  Accreditation  expiration  date;  and 
(j)  Scope  of  accreditation. 


7 


HOW  TO  LOCATE  SPECIFIC  INFORMATION 

For  a  laboratory  whose  name  is  known 

Refer  to  Index  A  and  note  the  laboratory's  NVLAP  Lab  Code.  Look  up  the  Lab  Code  in  Index  D  (if 
testing)  or  Index  E  (if  calibration)  to  obtain  specific  information  about  the  laboratory;  e.g.,  address, 
phone  number,  Scope  of  Accreditation,  etc. 

For  a  laboratory  in  a  particular  geographic  area 

Determine  the  states  (or  country)  included  in  the  geographic  area  of  interest.  Refer  to  Index  C  to  obtain 
the  NVLAP  Lab  Code  of  a  laboratory  within  the  selected  geographic  area  for  a  given  field  of 
accreditation.  Look  up  the  Lab  Code  in  Index  D  (if  testing)  or  Index  E  (if  calibration)  to  obtain  specific 
information  about  the  laboratory;  e.g.,  address,  phone  number,  Scope  of  Accreditation,  etc. 

For  a  laboratory  in  a  particular  field  of  accreditation 

Choose  the  field  of  accreditation  from  the  list  on  page  6.  Refer  to  Index  B  and  note  the  name  and  Lab 
Code  of  each  laboratory  of  interest.  Index  B  is  organized  by  field  of  accreditation  within  major  program 
group.  Look  up  the  Lab  Code  in  Index  D  (if  testing)  or  Index  E  (if  calibration)  to  obtain  specific 
information  about  the  laboratory;  e.g.,  address,  phone  number,  Scope  of  Accreditation,  etc. 

SPECIAL  NOTE  ABOUT  LABORATORIES  ACCREDITED  IN  ASBESTOS  FIBER  ANALYSIS 

The  test  method  designations  for  Bulk  Asbestos  Analysis  (PLM)  and  Airborne  Asbestos  Analysis  (TEM) 
are  as  follows: 


NVLAP 
Code 


Program  Title/Test  Method  Designation 


18/A01 


BULK  ASBESTOS  ANALYSIS  (PLM) 


U.S.  Environmental  Protection  Agency  (EPA)  "Interim  Method  for  the 
Determination  of  Asbestos  in  Bulk  Insulation  Samples"  as  found  in  40  Code  of 
Federal  Regulations  (CFR),  Part  763,  Subpart  F,  Appendix  A,  or  the  current 
U.S.  EPA  method  for  the  analysis  of  asbestos  in  building  material. 


18/A02 


AIRBORNE  ASBESTOS  ANALYSIS  (TEM) 


U.S.  Environmental  Protection  Agency  (EPA)  "Interim  Transmission  Electron 
Microscopy  Analytical  Methods— Mandatory  and  Nonmandatory— and  Mandatory 
Section  to  Determine  Completion  of  Response  Actions"  as  found  in  40  Code  of 
Federal  Regulations  (CFR),  Part  763,  Subpart  E,  Appendix  A. 


8 


# 


INDEX  A.  LISTING  BY  LABORATORY  NAME 

NVLAP  STATE/ 
LABORATORY  NAME  LAB  CODE    CITY  COUNTRY 


3 


*2 TV/f  Prnrlurt  Qq"Fp1"\/  PArlf"1  T  dHr\rctt"rtr\/ 
J  Ivi  liUUULL  OalCLy  U-IVIV^  LaUUI  alUl  y 

Qf-  Paul 
Ol.  i  dul 

1V11N 

3V  Fasteners  Co.  Inc.  Testing  Laboratory 

200264-0 

Corona 

CA 

A 

n  (x  D  E-IlVII  UIlIIlCIlLdl  oCIVlLcS,  IIIC- 

i ni iqi  n 

Houston 

TY 
1  A 

A  J.  LaDS 

lUlUoz-U 

Youngstown 

(JH 

A-Pex  International  Co.,  Ltd.  Yokowa 

nnn i no  a 

zuuiuy-o 

Mie-ken 

T  A  D  A  XT 

JAPAN 

Laboratory 

A.E.S.L. 

200303-0 

Tempe 

AZ 

A.R.C.  Laboratories,  Inc. 

1  A  1  O  T  O  A 

101832-0 

Grand  Forks 

ND 

AAC  trinity,  Inc. 

1  A  1  1  /"  O  A 

101 168-0 

Farmington  Hills 

MI 

/yjdivi  cn v  iruiiiiiciudi  v_/OiisuudiUo,  inc. 

l  n?ni  'v  n 

Long  Island  City 

isrv 

In  i 

/AccrcuiLtu.  cnviroiiincrudi  i  CLiinuiu^ics,  inc. 

i n i a^ l  n 

1 U 1 UJ  1  -u 

Media 

P  A 
rA 

A  rrrprlifprl  Fnvirnnmpnt^l  TppVmnlncnpc  Tnr* 

/A.L.^l  t  Ul  Lt  LI  JLvll  V  11  Ulli  1  ICllLal    1  CL-1 11 1 U 1 U  ci  1 1 D,  111L-. 

7009^6-0 

MP 

A  f^K/T  FnvirnnmPTitfll  Trie 
rivyivi  lii  v  ii  uiiii ltii Ldi,  inc. 

1  01 Q77-0 

^Aiitn  Rpnn 
OUUL11  JDCIIU 

11N 

7001 8S-0 

("InrA  R ronfO  Nyfi^r 
UU1U  UlullLU  1V1VJ 

RR  A  7IT 

Acoustic  Systems  Acoustical  Research 

100286-0 

Austin 

TX 

r  dciniy 

A  ptr^n  PnuirnrirTiPTitQ]  T^pctincr   Hnci  M^tinriQl 
t_.ll V  11  *J111 11C11  Idl   1  Collllg,  UUa  JNaliUlIal 

i nn^47-0 

1  UUj't  1 -\J 

DUAUU1  UUgll 

MA 

1  LLJllllCul    O  \  MLll  O 

Arlvanrp  Data  Tprhnnlncv  Comoration 

7001 07-0 

i  npi  \-\ <;i  pn 

1  ul  Utl  1  1  o  1  Cl  1 

TAIWA 

Advanced  Energy,  Industrial  Energy 

?00081-0 

R    pi  qY\ 

1  VCll  v_  1  ^ —  I  1 

NC 

T  ahoratorv 

AHvanrfrl  Tnriii^trial  Hvuiptip  ^%PT*virp<i  Tnr 

1  01  006-0 

N/T  i  ami 

1*1 1(11  in 

FL 

Aearo  Company,  E-A-RCAL  Acoustical 

100374-0 

Indianapolis 

IN 

T  ahoratnrv 

LdUUl  uLUl  y 

A  prr^ cr\Q  r*p  \TyI  flTc       q  cnnci/'iiQr'A/  r\T  trip 
/AClUiUdLC  IN  I  LUIS.  -  d  bUUMUlal  y  Ul  IIIC 

700771  0 

ndw  liiui  nc 

NT 

IN  J 

in  i  luj\  rdSLener  v^uipuidiiun 

Aerospace  Rivet  Manufacturers  Corp. 

200266-0 

Santa  Fe  Springs 

LA 

AGRA  Earth  and  Environmental,  Inc.  -  Env. 

20033  /-0 

Portland 

UK 

Chemistry  Laboratory 

AGX,  Inc. 

101578-0 

Cranberry  Township 

PA 

AHD 

1 A A 1  OA  A 

2UU12y-U 

Dowagiac 

Ml 

Aires  Consulting  Group,  Inc. 

1  A 1  A 1  A  A 
1U1U14-U 

Batavia 

TT 

IL 

AIResearch,  Inc. 

1 U  1  oOo-U 

Wauwatosa 

WT 
W 1 

Airtek  Environmental  Corp. 

1UZU1 l-U 

New  York 

In  Y 

Akzo  Kashima  Ltd.  Kakegawa  EMC  Test  Site 

i  nrnon  i 
l  uuzyu-z 

Shizuoka 

i  a  p  A  M 
J  ArnlN 

Akzo  Kashima  Ltd.,  Kashima  EMC  Site 

t  uuzyu-u 

Ibaraki 

T  A  P  A  XT 
J  ArAlN 

Akzo  Kashima  Ltd.,  Kawasaki  Technical 

TAA^AA  A 

Kawasaki 

TAPAM 

Center 

Akzo  Kashima  Ltd.,  Matsuda  EMC  Test  Site 

1  A  A  ^  C\  (\  A 

l 00290-4 

Kanagawa 

T  A  n  A  X  T 

JAPAN 

Akzo  Kashima  Ltd.,  Nagano  EMC  lest  Site 

1  AA")AA  T 

Nagano 

ta  n*M 

J  ArAlN 

Akzo  Kashima  Ltd.,  Tochigi  EMC  Test  Site 

1  A AO  A A  C 

100290-5 

Tochigi 

I  A  n  *  XT 

JAPAN 

ALAC 

200323-0 

Bronx 

NY 

Allegheny  Asbestos  Analysis 

1  A  1  1 A  /I  A 

101704-0 

Carnegie 

PA 

AlliedSignal  rM&  I  Metrology 

inn i Ac  a 
200108-0 

Kansas  City 

ML) 

All—         O     O  ^  "      1             T<       A "  

Alloy  &  Stainless  Testing 

1 A AT  CI  A 

200353-0 

Virginia  Beach 

\  T  A 

VA 

Alpine  Consulting,  Inc. 

102089-0 

Colorado  Springs 

CO 

AMA  Analytical  Services,  Inc. 

101143-0 

Lanham 

MD 

Ambient  Labs,  Inc. 

101618-0 

New  York 

NY 

American  Asbestos  Laboratories,  Inc. 

101775-0 

Miami 

FL 

American  Carpet  Laboratories,  Inc. 

100139-0 

Ringgold 

GA 

American  Electric  Power,  Environmental 

102102-0 

Columbus 

OH 

NVLAP  1999  DIRECTORY  -  Page  A3 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  A.  LISTING  BY  LABORATORY  NAME  -continued 

NVLAP  STATE/ 
LABORATORY  NAME  LAB  CODE    CITY  COUNTRY 


Laboratory 


Ampnran  IVfpHipal  T  nhnrafPirip^  Irtp 

ILUII  iVKUlLdl    LUUUI  ULUI  ILo,  lilt. 

1  \J  1  1  JU  \J 

Ch  qntillv 

v.  .  f  I  u  1 1  u  1 1  y 

VA 

Ampnf fin  Tpctinc  T  nhpiratnripc  Tnp 

rA.  1  1 1 1 1  1 1  ul  1    ItoLlllti  LjaUKJl  CtlUl  It  J,  lilt. 

1 001 46-0 

1  \J\J  i  tu  w 

LcXlltaolt  I 

PA 

Arnlah  I  I  C 

Oltl  "Hft 

PA 

Analvtira  ^snlnfiPiTTs  Tnp 

fallal  y  lit  a  JUl  unfile,  lilt. 

1  \J  1  \JO\J~\J 

R  r  Pi  o  m  fi  p  1 H 

Dl  UUU  llltltl 

Analytical  Environmental  Services 

200051-0 

Hato  Rey 

PR 

Tn  tprn  a  ti  on  fi  1  Inr 
unci  iialiuiiai,  int. 

A n 1  Fnvirptnmpnfal  ^pruirpc  Tnp 
/ai  iai  y  i  it  ai  L-i i  v  1 1  tun  i  it 1 1 iai  oti  v  itto,  nit. 

A  tl  ?in  tft 
rA.lla.1 1  La 

ha 

Analytical  Industries,  Inc. 

101855-0 

PaHnpah 

1    Cl\J  LI  \_  CI  1  1 

KY 

Analytical  Labs  San  Francisco,  Inc. 

101909-0 

San  Francisco 

CA 

Analyticalab 

101727-0 

Willow  Springs 

IL 

Aoyama  Fastener  Laboratory 

200213-0 

Niwa-gun,  Aichi  Prefecture 

JAPAN 

APA  -  The  Engineered  Wood  Association 

100423-0 

Tacoma 

WA 

RpcpQrpli  f~Vntpr 

l\.t  ot  ell  1 1 1  V  L  1 1  Lt  1 

A  npy  R  PQPnrph  T  ahnratnrv 

rVUtA  Ivtotultll  LuUUl  <Xl\Jl  V 

1071 1 8-0 

1  v j-.  1  1  O  \J 

XA/nitmnrp  T  nlt'P- 

YVlllllllUlt  LUM 

M  1 

j  VI  J 

Annlln  Pnvirnnmpntil  Tnp 

i  \ lj vj 1 1 n i v  1 1 \j i ii i iti i iai ,  nit- 

1 01 871 -0 

1  \J  1  O  /  1  w 

Cri  ncnntPtn 

VJ  lUoUll IU1 1 

PL 

Apple  Computer,  Inc.,  EMC  Compliance 

200071-0 

Cupertino 

CA 

T  ahoratnrv 

Applied  Environmental,  Inc. 

101611-0 

Reston 

VA 

Architectural  Testing  Inc. 

200361-0 

York 

PA 

Arden  Fasteners 

200187-0 

Addison 

IL 

Arizona  Public  Service  Co.,  Palo  Verde 

100536-0 

Tonopah 

AZ 

Nurlpur  Cipnprafinp  Station 

Annstrong  Acoustic  Labs,  Armstrong  World 

100228-0 

Lancaster 

PA 

Ind.,  Inc.  Innov.  Center 

A^akawa  9rrpw  Co    I  trl 

i\  JUlXuvv  d  i_)  1 1  t  W    \_.  \J .  ,  L,  Itl. 

200197-0 

Y"  Pi  \c  Pi  V)  ?K  TT1 7\ 
I  Urvt'llcllllil 

JAPAN 

A^ak'aw^  9ptpw  Co    I  trl  Kawawa  Faptnrv 

iT.oai\  a  w  a  otitw  v_  w . ,  Liti.  i  v  ti  w  ti  v  v  cx  i  atiwi y 

200257-0 

Y  pi  \c  n  \\  a  m  a 

1  UrvUl  Itll  1  Id 

JAPAN 

ASBESTECH 

101442-0 

Carmiphapl 

V>  Cll  1  1  ll\vll(ivl 

CA 

Asbestos  Analysis  and  Information  Service, 

101261-0 

Four  Oaks 

NC 

Inc . 

A 'shp'sto^  A nal vtlPfll 

101771-0 

Ti  ip  con 

AZ 

A  cHpctnc  Pnn ci i  1  hn <r  Ri  Tpctincr  (  A^T^ 

rtoUCMUj  V-  Ul  loUl  L 1 1        CX.    1  tollllL,  ^/t.v^  1  ^ 

101649-0 

i v i ut/  u 

LtllvAa 

k'  S 

IN.  O 

A  cKpctnc  TP\v4  T  ^Knrstnnpc  Tnp 
noUColUo   1  IjlVl  LaUUiallflICo,  lilt. 

1 01  S0 1 -0 

RptVpI  p\/ 
lj  1 1  ivt  icy 

CA 

AYoUCMUb  1  C1V1  l_.aUUl  aTUl  ito,  1I1C 

7001 04  0 

OUal  IVo 

NV 

1  N  V 

/\OV_   gtUStltllCt,  lilt. 

LaK.C  lallU 

PI 

/\SSdlgal  /\riaiyLltal  L-aUOralUI  ItS,  lilt. 

1 0 1 4S7  0 
1U1  *t  J  /  -u 

r\  1  L>  U  C|  U 1 1  C|  U  t 

MM 

i  ivesearcn,  inc.  civiv^  Lao. 

9001 0 

Irvine 

A  Tl*  A  ccnnirpc  In r> 
r\  1  \^  rVobUtldlCS  lilt. 

107071  0 
1  \JA\J  1  I  -U 

V_  lilt  lllllall 

OH 

ATC~"  A 's'sPiPiatp^  Tnp 

/v  i  v_-  rvoouc  i  cut  o  int. 

2002S0-0 

r^Piliimhi?! 
tui  ui  1 1  f  i  a 

MD 

ATC  A ,s<;pipiatp,s  Tnp 

?00290-0 

Dallas 

TX 

ATC  Assopiatps  Tnp 

101 187-0 

New  York 

NY 

ATC  Environmental,  Inc. 

102031-0 

Englewood 

CO 

Athenica  Environmental  Services,  Inc. 

101958-0 

Long  Island  City 

NY 

Atomic  Energy  Industrial  Laboratory  of  the 

100556-0 

Houston 

TX 

Southwest,  Inc. 

Aurora  Consolidated  Laboratories 

101661-0 

West  Allis 

Wl 

Austin  Anal vtiral  I  aborfitorv 

200014-0 

Austin 

TX 

B 

Rfiltimorp  Ci^<;  Ri  Plpptnp  Cnmnanv 

LJ  CI  1  Mil  IU1  t   VJ  Cio  CX    LILLU  It  \^  \Jl  1  lUdllV 

100501-0 

Lusby 

MD 

BarTech  Inc.  -  Chemical  Laboratory 

200148-0 

Johnstown 

PA 

Batta  Laboratories,  Inc. 

101032-0 

Newark 

DE 

Battelle  -  Pacific  Northwest  National 

200216-0 

Richland 

WA 

Laboratory 

Bay  Area  Air  Quality  Management  District 

102090-0 

San  Francisco 

CA 

NVLAP  1999  DIRECTORY  -  Page  A4 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  A.  LISTING  BY  LABORATORY  NAME  -  continued 

NVLAP  STATE/ 

LABORATORY  NAME  LAB  CODE    CITY  COUNTRY 

Bay  Area  Compliance  Laboratory,  Corp.  200167-0  Sunnyvale  CA 

BCAG  Fastener  Quality  Test  Lab  Everett  Site   200292-0  Seattle  WA 

Beaulieu  of  America  -  Carpet  Testing  Lab  100190-0  Dalton  GA 

Belgo-Mineira  Chemical  Laboratory  200196-0  35.930-900  Joao  Monlevade  BRAZIL 

Beling  Consultants,  Inc.  101356-0  Moline  IL 

Bell  Laboratories,  Division  Lucent  101965-0  Murray  Hill  NJ 

Technologies,  Inc. 

Bentley  Testing  Laboratory  100288-0  City  of  Industry  CA 

Binder  Metal  Products,  Inc.  200321-0  Gardena  CA 

Bodycote  Industrial  Testing,  Inc.  101072-0  St.  Louis  MO 

Braun  Intertec  Corporation  101234-0  Minneapolis  MN 

c 

Cabletron  Systems,  Inc.  200121-0  Rochester  NH 

California  Screw  Products  200183-0  Paramount  CA 

CAM  Environmental  Services,  Inc.  200240-0  Pasadena  TX 

CAMCOLab  101803-0  Fontana  CA 

Canadian  Standards  Association  100322-0  Etobicoke  Ontario  CANADA 

Cape  Environmental  Management,  Inc.  102111-0  Atlanta  GA 

Carnow,  Conibear  &  Associates  Ltd.  101039-0  Chicago  IL 

Carolina  Environmental,  Inc.  101768-0  Cary  NC 

Carolina  Power  &  Light  Company,  Harris  100517-0  New  Hill  NC 
Energy  &  Enviro.  Center 

Casey  Products,  Inc.  200278-0  Lisle  IL 

CBS  Fasteners,  Inc.  200253-0  Anaheim  CA 

CDRH  X-Ray  Calibration  Laboratory  105018-0  Rockville  MD 

Celestica  International  Inc.  200055-0  North  York,  Ontario  CANADA 

Celotex  Technical  Center  100417-0  St.  Petersburg  FL 

Chatfield  Technical  Consulting  Limited  101103-0  Mississauga  Ontario  CANADA 

Chemitox  EMC  Research,  Inc.  200120-0  Yamanashi-ken  JAPAN 

ChemScope,  Inc.  101061-0  North  Haven  CT 

CHEMTEX  Environmental  Laboratory,  Inc.  200025-0  Port  Arthur  TX 

Chomerics  Test  Services  (CTS)  100296-0  Woburn  MA 

Chopra-Lee,  Inc.  200095-0  Grand  Island  NY 

Cisco  Systems,  Inc.  200114-0  San  Jose  CA 

City  of  Los  Angeles  Department  of  Water  and   101111-0  Los  Angeles  CA 
Power 

City  of  San  Jose,  Materials  Testing  100325-0  San  Jose  CA 
Laboratory 

Clark  Seif  Clark,  Inc.  200324-0  Chatsworth  CA 

Clayton  Environmental  Consultants  101106-0  Seattle  WA 

Clayton  Laboratory  Services  101125-0  Kennesaw  GA 

Clinton  Power  Station  100570-0  Clinton  IL 

Combustion  Engineering,  Inc.  100563-0  Windsor  CT 

ComEd  -  TLD  Processing  Lab  -  CTEAM  100541-0  Bolingbrook  IL 
Facility 

Commercial  Testing  Company  100120-0  Dalton  GA 

Communication  Certification  Laboratory  100272-0  Salt  Lake  City  UT 

Compaq  Computer  Corp.  EMC  Test  Facility  200078-0  Colorado  Springs  CO 

Compaq  Computer  Corp.  Emissions  Control  200058-0  Houston  TX 
Lab 

Compaq  Corporate  Metrology  200154-0  Houston  TX 

Compatible  Electronics,  Inc.  200063-0  Agoura  CA 

Compliance  Eng.  Svces,  Inc.,  Compliance  200065-0  Sunnyvale  CA 
Certification  Services 


NVLAP  1999  DIRECTORY  -  Page  A5 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  A.  LISTING  BY  LABORATORY  NAME  -  continued 


LABORATORY  NAME 


NVLAP 
LAB  CODE 


CITY 


STATE/ 
COUNTRY 


Compliance  Engineering  Services,  Inc.  - 
Taiwan 

Compliance  Test  Laboratories,  Inc. 
Composite  Panel  Association  (CPA) 
Comprehensive  Health 
Services-Environmental  Health  PLM 
Laboratory 

Con  Edison  -  ChemLab 

Con  Edison,  Indian  Point 

Concord  Analysis,  Inc. 

Continental  Envirotech,  Inc. 

Control  Data  Accredited  OSI  Test  Center 

Converse  Consultants  MR,  Inc. 

Cooper  Lighting  -  Metalux  Research 

Laboratories 

Cosmos  Corporation 

Covino  Environmental  Associates,  Inc. 

Craig  Environmental  Services,  Inc. 

Crisp  Analytical  Laboratory 

Criterion  Laboratories,  Inc. 

Criterion  Technology 

Cryptographic  Equipment  Assessment  Lab. 
(CEAL) 

CT&E  Environmental  Services  Inc. 
CTL  Environmental  Services 
Curtis-Straus  LLC 


200064-0  Sunnyvale 

200237-0  Liberty 

100418-0  Gaithersburg 

101759-0  Kennedy  Space  Center 


101558-0  Long  Island  City 

100538-0  Buchanan 

101884-0  Chatsworth 

200080-0  Mesa 

100354-0  Arden  Hills 

102091-0  Reno 

200050-0  Americus 

200151-0  Watarai-gun  Mie 

101781-0  Woburn 

200289-0  Mays  Landing 

200349-0  Carrollton 

102046-0  Bensalem 

100396-0  Rollinsville 

200002-0  McLean 

200067-0  San  Diego 

101216-0  Harbor  City 

200057-0  Littleton 


D 

D.L.S.  Electronic  Systems,  Inc.  100276-0  Wheeling 

D/L  Laboratories  100252-0  New  York 

Dames  &  Moore,  Inc.  101433-0  Salem 

Data  General  Corporation  100339-0  Westboro 

DataChem  Laboratories  101917-0  Cincinnati 

Davis  &  Floyd,  Inc.  101410-0  Greenwood 

Daybrite  Lighting  (Genlyte  Thomas  Group)      200016-0  Tupelo 
Photometric  Laboratory 

DCM  Science  Laboratory,  Inc.  101258-0  Wheat  Ridge 

Dell  Regulatory  Test  Laboratories  200052-0  Round  Rock 

Denver  Instrument  Co.  Weight  Lab  200106-0  Arvada 

Department  of  Environmental  Health  101530-0  San  Diego 
Industrial  Hygiene  Laboratory 

Design  for  Health,  Inc.  101 864-0  San  Diego 

Detroit  Edison,  Fermi  2  Dosimetry  100529-0  Newport 
Laboratory 

Dexter  Fastener  Technologies,  Inc.  200144-0  Dexter 

DHMH-Air  Quality  Laboratory  101523-0  Baltimore 

Digital  Regulatory  Engineering  and  Testing      100413-0  Marlboro 
Services 

Diviersified  T.E.S.T.  Technologies,  Inc.  200340-0  Groton 

Dixon  Information  Inc.  101012-0  South  Salt  Lake 

DLZ  Laboratories,  Inc.  101060-0  Columbus 

Dodge-Regupol,  Inc.  Laboratory  200030-0  Lancaster 

Dolphin  Environmental  Consultants  102086-0  Stafford 

DOMUS  ITSL,  a  division  of  LGS  Group,  200017-0  Ottawa  Ontario 
Incorporated 


CA 

sc 

MD 
FL 


NY 
NY 
CA 
AZ 
MN 
NV 
GA 

JAPAN 

MA 

NJ 

TX 

PA 

CO 

VA 

CA 
CA 
MA 


IL 

NY 

NH 

MA 

OH 

SC 

MS 

CO 
TX 
CO 
CA 

CA 
MI 

MI 

MD 
MA 

NY 
UT 
OH 
PA 
TX 

CANADA 


NVLAP  1999  DIRECTORY  -  Page  A6 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  A.  LISTING  BY  LABORATORY  NAME  -  continued 


NVLAP 

STATE/ 

LABORATORY  NAME 

LAB  CODE 

CITY 

COUNTRY 

Dove  Environmental  Corporation 

102053-0 

Miami 

FL 

Dow  Chemical  N.  America  Foam  Products 

100103-0 

Midland 

MI 

Research,  Prod.  Perf.  Lab. 

Duke  Engineering  and  Services 

100524-0 

Bolton 

MA 

Environmental  Laboratory 

Duke  Power  Company  Dosimetry  Laboratory 

100505-0 

Charlotte 

NC 

Duquesne  Light  Company,  Beaver  Valley 

100521-0 

Shippingport 

PA 

Power  Station 

Durkee  Testing  Laboratories,  Inc. 

200178-0 

Paramount 

CA 

Duro-Test  Corporation 

200283-0 

Clifton 

NJ 

E 

E.  M.  Analytical,  Inc. 

101902-0 

Dania 

FL 

EA  Group 

101019-0 

Mentor 

OH 

EAI,  Inc. 

102114-0 

Jersey  City 

NJ 

Eastern  Analytical  Services,  Inc. 

101646-0 

Elmsford 

NY 

Eastern  Materials  Testing  Lab  a  division  of 

100315-0 

New  Britain 

CT 

Jaworski  Geotech 

Eastman  Kodak  Co. -Regulatory  Compliance 

200313-0 

Rochester 

NY 

Center-EMC  Facility 

Eaton  E3  Laboratory 

100382-0 

Southfield 

MI 

Eberline  Dosimetry  Service 

100515-0 

Albuquerque 

NM 

EcoSystems  Environmental,  Inc. 

101162-0 

Carrollton 

TX 

ECS/Wagner  Environmental 

101064-0 

Eugene 

OR 

EEC,  Inc. 

101088-0 

Raleigh 

NC 

Electric  Boat  Corp/A  General  Dynamics  Co. 

100560-0 

Groton 

CT 

Radiological  Ctrl.  Dept 

Electro  Magnetic  Test,  Inc. 

200147-0 

Mountain  View 

CA 

Electro.  Meas.  Off.,  Yokohama  Res.  &  Dev. 

200263-0 

Kanagawa 

JAPAN 

Ctr.  Murata  Mfg.  Co. 

Electronic  Compliance  Laboratories,  Inc. 

200089-0 

Sunnyvale 

CA 

Electronic  Research  &  Service 

200118-0 

Hsinchu 

TAIWAN 

Organization/ITRI 

Electronics  Test  Centre 

200282-0 

Kanata,  Ont. 

CANADA 

Electronics  Testing  Center,  Taiwan 

200133-0 

Taoyuan  Hsien 

TAIWAN 

Elite  Electronic  Engineering  Company 

100278-0 

Downers  Grove 

IL 

Elliott  Laboratories,  Inc. 

200069-0 

Sunnyvale 

CA 

EMC  Compliance  Mgmt  Group,  dba 

200068-0 

Mountain  View 

CA 

Turntech  Scientific  &  Instr.,  Inc. 

EMC  International,  Inc. 

200094-0 

Youngsville 

NC 

EMC  Kashima  Corporation 

200070-0 

Chiba-ken 

JAPAN 

EMCE  Engineering,  Inc. 

200092-0 

Fremont 

CA 

EMS  Laboratories,  Inc. 

101218-0 

Pasadena 

CA 

EMSL  Analytical  Mobile  Laboratory 

200344-0 

Chicago 

IL 

EMSL  Analytical,  Inc. 

101048-0 

Westmont 

NJ 

EMSL  Analytical,  Inc. 

101048-1 

Atlanta 

GA 

EMSL  Analytical,  Inc. 

101048-2 

Piscataway 

NJ 

EMSL  Analytical,  Inc. 

101048-3 

San  Mateo 

CA 

EMSL  Analytical,  Inc. 

101048-4 

Ann  Arbor 

MI 

EMSL  Analytical,  Inc. 

101048-9 

New  York 

NY 

EMSL  Analytical,  Inc. 

101048-10 

Carle  Place 

NY 

EMSL  Analytical,  Inc. 

101277-0 

Fairfax 

VA 

EMSL  Analytical,  Inc. 

102104-0 

Greensboro 

NC 

EMSL  Analytical,  Inc. 

102105-0 

Warwick 

RI 

EMSL  Analytical,  Inc. 

102106-0 

Houston 

TX 

NVLAP  1999  DIRECTORY  -  Page  A7  (See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  A.  LISTING  BY  LABORATORY  NAME  -  continued 


LABORATORY  NAME 

NVLAP 
LAB  CODE 

CITY 

STATE/ 
COUNTRY 

EMSL  Analytical,  Inc. 

200019-0 

Seattle 

WA 

EMSL  Analytical,  Inc. 

200034-0 

Dallas 

TX 

EMSL  Analytical,  Inc. 

200056-0 

Williamsville 

NY 

EMSL  Analytical,  Inc. 

200188-0 

Indianapolis 

IN 

EMSL  Analytical,  Inc. 

200204-0 

N.  Miami  Beach 

FL 

EMSL  Analytical,  Inc. 

200247-0 

Charlotte 

NC 

EMSL  Analytical,  Inc. 

200293-0 

Beltsville 

MD 

EMSL  Analytical,  Inc. 

200310-0 

Carlstadt 

NJ 

EMSL  Analytical,  Inc. 

200333-0 

Elmsford 

NY 

EMSL  Analytical,  Inc. 

200375-0 

Baton  Rouge 

LA 

ENCORP 

200013-0 

El  Segundo 

CA 

Entergy  Operations,  Inc. 

100535-0 

Taft 

LA 

Enviro  Techniques,  Inc. 

200024-0 

Paterson 

NJ 

Enviro-Probe,  Inc. 

101222-0 

Bronx 

NY 

EnviroHealth  Technologies,  Inc. 

200374-0 

St.  Louis 

MO 

EnviroMed  Services,  Inc. 

101514-0 

New  Haven 

CT 

Environmental  Enterprise  Group(EEG),  Inc. 

101587-0 

Russellville 

AR 

Environmental  Hazards  Services,  L.L.C. 

101882-0 

Richmond 

VA 

Environmental  Health  Laboratories 

101506-0 

Clayton 

MO 

Environmental  Management  Consultants,  Inc. 

101926-0 

Scottsdale 

AZ 

Environmental  Monitoring  &  Consulting 

101087-0 

Somerville 

NJ 

Associates 

Environmental  Services  International,  Inc. 

101306-0 

St.  Albans 

WV 

Environmental  Testing  and  Monitoring 

200131-0 

Virginia  Beach 

VA 

Services,  Inc. 

Environmental  Testing  Laboratories,  Inc. 

101937-0 

Farmingdale 

NY 

Environmental  Testing,  Inc. 

101848-0 

Middletown 

DE 

EnvironMETeo  Services  Inc. 

101807-0 

Waipahu 

HI 

Envirotest,  Inc. 

101595-0 

Houston 

TX 

ERI  Consulting  Engineers,  Inc. 

101232-0 

Tyler 

TX 

ERT  Testing  Services 

101295-0 

Highland  Park 

MI 

ESG  Laboratories 

102029-0 

Indianapolis 

IN 

EssTek  Ohio,  Inc. 

102093-0 

Middleburg  Heights 

OH 

Fabristeel  Products  Inc. 

200329-0 

Taylor 

MI 

Fairfield  Testing  Laboratory,  Inc. 

100317-0 

Stamford 

CT 

Fairway  Testing  Company,  Inc. 

100340-0 

Stony  Point 

NY 

Fastener  Innovation  Technology,  Inc. 

200179-0 

Gardena 

CA 

Federal  Manufacturing  Corp. 

200279-0 

Chatsworth 

CA 

Fiberquant,  Inc. 

101031-0 

Phoenix 

AZ 

Fibertec,  Inc. 

101510-0 

Holt 

MI 

Flexible  Products  Company 

100210-0 

Joliet 

IL 

Florida  Power  &  Light  Company 

100544-0 

Juno  Beach 

FL 

Fluke  Corporation  Primary  Standards 

105016-0 

Everett 

WA 

Laboratory 

Fluor  Daniel  Fernald,  Inc.,  Analytical 

102010-0 

Cincinnati 

OH 

Laboratory  Services 

Fong  Prean  Industrial  Co.,  Ltd. 

200288-0 

Kaohsiung  Hsien 

TAIWAN 

Forensic  Analytical  Specialties,  Inc. 

101459-0 

Hayward 

CA 

Forensic  Analytical  Specialties,  Inc. 

101459-1 

Rancho  Domingues 

CA 

Fountain  Compliance  Laboratory 

200101-0 

Somerset 

NJ 

Froehling  &  Robertson,  Inc. 

102060-0 

Richmond 

VA 

FRS  Geotech,  Inc. 

102078-0 

Denver 

CO 

Fuji  Buhin  Kogyo  Kabushiki  Kaisha 

200203-0 

Ohta  Gunma 

JAPAN 

Fuji  Component  Parts  USA,  Inc. 

200180-0 

Indianapolis 

IN 

NVLAP  1999  DIRECTORY  -  Page  A8 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  A.  LISTING  BY  LABORATORY  NAME  -  continued 


LABORATORY  NAME 


NV  LAP 
LAB  CODE 


CITY 


STATE/ 
COUNTRY 


Fujitsu  Evaluation  Engineering  Laboratory  20028 1  -0 

Fujitsu  General  EMC  Laboratory  200373-0 

Fuserashi  Gunma  200173-0 

Fwu  Kuang  Enterprises  Co.,  Ltd.  200286-0 


Numazu,  Shizuoka-Pref.  JAPAN 

Kawasaki  JAPAN 

Gunma-Ken  JAPAN 

Tainan  Hsien  TAIWAN 


GA  Environmental  Services,  Inc.  101996-0  Eddystone 

Galson  Laboratories  101375-0  East  Syracuse 

Garwood  Laboratories,  Inc.  200119-0  Placentia 

GE  Industrial  Systems,  Renewal  Services  -       200029-0  Rome 
TEMS 

GE  Lighting- Engineering  Support  -  NA  100398-0  Cleveland 

GE  Owensboro  Test  Laboratory  200305-0  Owensboro 

GEC  Marconi  Avionics  Ltd  Environmental      200304-0  Kent 
and  EMC  Test  Center 

Gelles  Laboratories,  Inc.  101170-0  Columbus 

Geo- Analytical  Services,  Inc.  102082-0  Atlanta 

Georgia  Power  Company/Enviro.  Affairs,  100551-0  Smyrna 
Enviro.  Lab-Dosimetry 

Geoscience  Ltd.  100142-0  San  Diego 

Ginna  Nuclear  Station  100514-0  Ontario 

GLE  Associates,  Inc.  102003-0  Tampa 

Global  EMC  Standard  Tech.  Corp.  200085-0  Taipei  County 

GPU  Nuclear  Chemistry/Materials  Labs.  102064-0  Reading 

GPU  Nuclear  Corp.  1 005 1 0-0  Middletown 

Guardian  Laboratories  101399-0  Louisville 

H 

Hadd-Co  Inspection  Lab  200326-0  Torrance 

Hayes  Microcomputer  Products,  Inc.  200103-0  Atlanta 

Health  Science  Associates  101384-0  Los  Alamitos 

Henderson/Longfellow  Associates,  Inc.  102077-0  St.  Petersburg 

Henry  Troemner,  Inc.  105013-0  Philadelphia 

Hewlett  Packard,  Product  Test  Lab,  San  200138-0  San  Diego 
Diego 

Hi-Tech  Environmental  and  Laboratory  102013-0  Cypress 
Services 

HIH  Laboratory,  Inc.  101233-0  Webster 

Hillmann  Environmental  Company  1 0 1 42 1  -0  Union 

Hitachi  Information  Technology  Co.,  Ltd.  200186-0  Kanagawa 
Nakai  Test  Site 

Hollytex  Carpet  Mills,  Inc.  100247-0  Anadarko 

Holometrix  -  Micromet  100113-0  Bedford 

HomeTek  Technology  Inc.  200331-0  Taipei  Shien 

HPNW  100567-0  Tigard 

Hub  Testing  Laboratory,  Inc.  101045-0  Waltham 

Hubbell  Lighting  Photometric  Laboratory  200020-0  Christiansburg 

Hufcor  Laboratory  100239-0  Janesville 

Hygeia  Laboratories  Inc.  1 02 1 1 6-0  Sierra  Madre 

Hygeia  Laboratories,  Inc.  101011-0  Woburn 

Hygeia  Laboratories,  Inc.  102087-0  Marietta 

Hygeia  Laboratories,  Inc.  200335-0  Miami 

HYGENIX,  INC.  101199-0  Stamford 

Hygieneering,  Inc.  101997-0  Willowbrook 

Hygienetics  Laboratory  Services  101147-0  Boston 


PA 
NY 
CA 
NY 

OH 
KY 

UNITED  KINGDOM 

OH 
GA 
GA 

CA 
NY 
FL 

TAIWAN 
PA 
PA 
KY 


CA 
GA 
CA 
FL 
PA 
CA 

CA 

TX 
NJ 

JAPAN 

OK 
MA 

TAIWAN 

OR 

MA 

VA 

WI 

CA 

MA 

GA 

FL 

CT 

IL 

MA 


NVLAP  1999  DUtECTORY  -  Page  A9 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  A.  LISTING  BY  LABORATORY  NAME  -  continued 

NVLAP  STATE/ 
LABORATORY  NAME  LAB  CODE    CITY  COUNTRY 


I 

IBM  Austin  EMC  200112-0 

IBM  Charlote  EMC  Facility  200337-0 

IBM  Hudson  Valley  Acoustics  Laboratory  100323-0 

IBM  Rochester  EMC  Lab  20009 1  -0 

IBM  RTP  PSG  EMC  Test  Labs  200200-0 

IBM  Yamato  EMC  Engineering  200198-0 

ICN  Dosimetry  Service,  Div.  of  ICN  1 00555-0 
Biomedicals,  Inc. 

ILX  Lightwave  Corporation,  Optical  2002 1 1  -0 
Calibration 

Incotec  Laboratory  200339-0 
Independent  Materials  Testing  Laboratories,  1 003 1 6-0 
Inc. 

Independent  Textile  Testing  Service,  Inc.  100166-0 

Indiana  Automotive  Fasteners,  Inc.  200150-0 

Industrial  Acoustics  Company,  Inc.,  100404-0 
Aero-Acoustics  Laboratory 

Industrial  Laboratory  102115-0 

InFocus  Systems,  Inc.  200152-0 

InfoGard  Laboratories,  Inc.  100432-0 

Ingersoll  Fasteners  200208-0 

Inland  Foundation  Engineering,  Inc.  100406-0 

Institute  for  Environmental  Assessment  1 0 1 249-0 

Instron  Force  Calibration  Laboratory  105023-0 

Instrument  Specialties  Co.,  Inc.  200076-0 

Integrity  Design  &  Test  Services,  Inc.  200004-0 
Intermec  Technologies  Corporation,  Norand  100269-0 
Mobile  System  Division 

International  Asbestos  Testing  Laboratory  101 165-0 

International  Standards  Laboratory  200234-0 

Intertek  Testing  Services  20020 1  -0 

Intertek  Testing  Services  N  A  Inc.  1 00270-0 

Intertek  Testing  Services  NA  Inc.  1 00274-0 

Intertek  Testing  Services  NA  Inc.  1 00402-0 

Intertek  Testing  Services  NA  Inc.  1 00409-0 

Intertek  Testing  Services  NA  Inc.  20003 1  -0 

Intertek  Testing  Services  NA  Inc.  200297-0 

Intertek  Testing  Services  NA,  Inc.  200049-0 

Iowa  Environmental  Services,  Inc.  101990-0 

IPS  Corporation  200012-0 

ITEK  Enviro  Services,  Inc.  200032-0 
Ivaco  Rolling  Mills,  Chemistry  Laboratory  200143-0 


Austin 
Charlotte 
Poughkeepsie 
Rochester 

Research  Triangle  Park 
Yamato  Kanagawa 
Costa  Mesa 

Bozeman 

Mojave 
Plainville 

Dalton 

Greenfield 

Bronx 

Portsmouth 
Wilsonville 
San  Luis  Obispo 
Ingersoll  Ontario 
San  Jacinto 
Brooklyn  Park 
Canton 

Delaware  Water  Gap 

Littleton 

Cedar  Rapids 

Mt.  Laurel 

Hsichih  Chen,  Taipei 

Menlo  Park 

Boxborough 

Lexington 

Cortland 

Norcross 

Middleton 

Laguna  Niguel 

Oakdale 

Des  Moines 

Nagano 

South  San  Francisco 
L'Orignal  Ontario 


TX 
NC 
NY 
MN 
NC 

JAPAN 
CA 

MT 

CA 
CT 

GA 

IN 

NY 

VA 
OR 

CA 

CANADA 

CA 

MN 

MA 

PA 

MA 

IA 

NJ 

TAIWAN 

CA 

MA 

KY 

NY 

GA 

WI 

CA 

MN 

I A 

JAPAN 
CA 

CANADA 


J.W.  Mfg.  DBA  Van  Petty  Mfg.  200225-0  Newbury  Park 

Japan  Quality  Assurance  Org.  Chubu  Testing    200190-0  Aichi 
Center  Shikatsu  Branch 

Japan  Quality  Assurance  Org.  Safety  Testing    200192-0  Yamanashi 
Ctr.  Tsuru  EMC  Branch 

Japan  Quality  Assurance  Organization  200191-0  Osaka 

Kita-Kansai  Testing  Center 

Japan  Quality  Assurance  Organization  Safety    200189-0  Tokyo 
Testing  Center 


CA 

JAPAN 
JAPAN 
JAPAN 
JAPAN 


NVLAP  1999  DIRECTORY  -  Page  A10 


(See  *How  To  Use  This  Directory'  on  page  7.) 


INDEX  A.  LISTING  BY  LABORATORY  NAME  -  continued 


LABORATORY  NAME 

NVLAP 
LAB  CODE 

CITY 

STATE/ 
COUNTRY 

Jimmie  Ann  Bolton 

101735-0 

Austin 

TX 

JLC  Environmental  Consultants,  Inc. 

101953-0 

New  York 

NY 

JMS  Environmental  Associates,  Ltd. 

102012-0 

Westmont 

IL 

Johns  Manville  Technical  Center 

100425-0 

Littleton 

CO 

K 

KAM  Consultants 

102047-0 

Long  Island  City 

NY 

Kansai  Electronic  Industry  Development 

200207-0 

Ikoma  Nara 

JAPAN 

Center,  Ikoma  Testing  Lab. 

Kellco  Services,  Inc. 

101331-0 

Hayward 

CA 

Kevco  Services,  Inc. 

101941-0 

Butler 

PA 

Key  Tronic  Corp. 

200096-0 

Spokane 

WA 

Kingston  Environmental  Laboratory 

200041-0 

Lee's  Summit 

MO 

Knauf  Fiber  Glass  Research  Laboratory 

100248-0 

Shelbyville 

IN 

Kobelco  Research  Institute,  Inc.  Stock 

200169-0 

Kobe 

JAPAN 

Company 

Korea  Testing  &  Research  Inst,  for  Chemical 

200177-0 

Inchon 

KOREA 

Industry-Inchon  Off. 

Korea  Tokin  EMC  Engineering  Co.,  Ltd. 

200220-0 

Namyangju-si,  Kyunggi-Do 

KOREA 

KTL  Dallas,  Inc. 

100426-0 

Lewisville 

TX 

KTL  Ottawa  Inc. 

100351-0 

Ottawa  Ontario 

CANADA 

Kyowa  Kogyosyo  Co.,  Ltd.  Test  Laboratory 

200274-0 

Komatsu  City,  Ishikawa 

JAPAN 

L 

LA  Testing 

200232-0 

S.  Pasadena 

CA 

Lab/Cor,  Inc. 

101920-0 

Seattle 

WA 

Labcorp  Analytics  Laboratory 

101004-0 

Richmond 

VA 

LambdaMetrics,  Inc. 

200122-0 

Cedar  Park 

TX 

Landauer,  Inc. 

100518-0 

Glenwood 

IL 

Larron  Laboratory 

101415-0 

Cape  Girardeau 

MO 

Law  Engineering  and  Environmental 

101066-0 

Birmingham 

AL 

Services,  Inc. 

Law  Engineering  and  Environmental 

101152-0 

Houston 

TX 

Services,  Inc. 

Law  Engineering  and  Environmental 

101226-0 

Charlotte 

NC 

Services,  Inc. 

Law  Engineering  and  Environmental 

101515-0 

Tampa 

FL 

Services,  Inc. 

Law  Engineering  and  Environmental 

101515-1 

Miami  Lakes 

FL 

Services,  Inc. 

Law  Engineering  and  Environmental 

101847-0 

Sterling 

VA 

Services,  Inc. 

Law  Engineering  and  Environmental 

101973-0 

Dallas 

TX 

Services,  Inc. 

Law  Engineering  and  Environmental 

102035-0 

Phoenix 

AZ 

Services,  Inc. 

Legend  Technical  Services,  Inc. 

102081-0 

St.  Paul 

MN 

Leland-Powell  Fasteners,  Inc.  Fastener 

200171-0 

Martin 

TN 

Testing  Laboratory 

Levecque  Technical  Center 

100101-0 

Blue  Bell 

PA 

LG  Electronics,  Inc.,  Quality  and  Reliability 

200040-0 

Seoul 

KOREA 

Center 

Liberty  Labs,  Inc. 

ZUU 1 Zj-U 

i\.irriL)aiiLuii 

1  A 

Lithonia  Testing  Laboratories 

200007-0 

Conyers 

GA 

Lockheed  Martin  Control  Systems  EMI 

200142-0 

Johnson  City 

NY 

NVLAP  1999  DIRECTORY  -  Page  All 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  A.  LISTING  BY  LABORATORY  NAME  -  continued 


LABORATORY  NAME 


NVLAP 
LAB  CODE 


CITY 


STATE/ 
COUNTRY 


Laboratory 

Lockheed  Martin  Idaho  Tech.  Co.,  Standards 

and  Calibration  Lab. 

Lockheed  Martin  Technical  Operations 

Lockheed  Martin  Utility  Services,  Inc. 

Loflin  Environmental  Services 

Los  Angeles  Harbor  Department  Testing 

Laboratory 

Los  Angeles  Unified  School  District 
Louisiana  Department  of  Environmental 
Quality  Microanalytical  Lab 
Lucent  Technologies,  Global  Product 
Compliance  Lab 

M 

M&M  Manufacturing  Corportation 


200115-0 

105017-0 
101383-0 
102044-0 
102020-0 

101505-0 
102000-0 

100275-0 


200356-0 


Idaho  Falls 

Sunnyvale 
Piketon 
Houston 
Wilmington 

Los  Angeles 
Baton  Rouge 

Holmdel 


Chino 


ID 

CA 
OH 
TX 
CA 

CA 
LA 

NJ 


CA 


m 

m.a.c.  Paran  Consulting  Services,  Inc.  102108-0 

M 

MAC  Fasteners,  Inc.  200 1 4 1  -0 

MacLean  Fasteners  -  QC  Laboratory  200153-0 

MacMillan  Bloedel  Packaging,  Inc.,  1 00259-0 
Combined  Board  Test  Lab 

MACS  Lab,  Inc.  101948-0 

MagneTek  (Lexington)  Engineering  200053-0 
Laboratory 

Mallinckrodt  Group,  Inc.  100503-0 
Marathon  Electric  -  Wausau  Engineering  Lab.  200134-0 

Marine  Chemist  Service,  Inc.  101425-0 

Materials  Analytical  Services,  Inc.  101235-0 

Materials  Testing,  Inc.  100320-0 

Matsushita  EMC  Center  1 00428-0 

Maxim  Technologies,  Inc.  101091-0 

Maxim  Technologies,  Inc.  1 0 1 09 1  - 1 

Maxim  Technologies,  Inc.  101292-0 

Maxim  Technologies,  Inc.  200046-0 

McCall  and  Spero  Environmental,  Inc.  101895-0 

McK.ee  Environmental  Health,  Inc.  101 135-0 

Meidoh  Laboratory  200239-0 

MET  Laboratories,  Inc.  100273-0 

Metallic  Material  Laboratory  in  Toyota  200223-0 
Motor  Co. 

Metroplex  Metrology  Lab,  Inc.  200262-0 
Metropolitan  Environmental  Testing  Services  200165-0 
dba  METS  Laboratories 

Michael  &  Associates  1 00427-0 

Micro  Air  of  Texas,  Inc.  1 02008-0 

Micro  Air,  Inc.  101221-0 

Micro  Analytical  Laboratories,  Inc.  101151-0 

Micro  Analytical  Laboratories,  Inc.  101872-0 

Micro  Analytical  Laboratories,  Inc.  200054-0 

Micro  Analytical,  Inc.  101247-0 

Microbac  Laboratories,  Inc.  101035-0 


Amelia 


Ottawa 
Mundelein 
Pine  Hill 

Santa  Clara 
Lexington 

Maryland  Heights 
Wausau 
Newport  News 
Suwanee 
Milford 

Taki-gun,  Hyogo 

Dallas 

Houston 

Billings 

St.  Paul 

Louisville 

Friendswood 

Toyota,  Aichi 

Baltimore 

Toyota  city  Aichi 

Fort  Worth 
Waldorf 

State  College 

Houston 

Indianapolis 

Gainesville 

Emeryville 

San  Francisco 

Milwaukee 

Erie 


OH 


KS 

IL 

AL 

CA 
TN 

MO 

WI 

VA 

GA 

CT 

JAPAN 

TX 

TX 

MT 

MN 

KY 

TX 

JAPAN 

MD 

JAPAN 

TX 
MD 

PA 

TX 

IN 

FL 

CA 

CA 

WI 

PA 


NVLAP  1999  DIRECTORY  -  Page  A12 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  A.  LISTING  BY  LABORATORY  NAME  -  continued 


LABORATORY  NAME 

NVLAP 
LAB  CODF 

CITY 

STATE/ 
COUNTRY 

Micron  Environmental  Labs 

200294-0 

Arcadia 

CA 

Microscopic  Analysis,  Inc. 

1  A  1  A  ~>  "7  A 

101037-0 

St.  Louis 

MO 

Midwest  Laboratories,  Inc. 

1  A  1  QClA  A 

Countryside 

1L 

Minebea  Co.,  Ltd.  Fujisawa  Manufacturing 

zuuzzy-u 

Fujisawa,  Kanagawa 

I  A  P  A  XT 

Unit 

Minnesota  Metrology  Laboratory 

1  A  C  A  A 1  A 

105003-0 

St.  Paul 

MN 

Modern  Plating  Corporation 

inn )iA  a 

200320-0 

hreeport 

TT 

IL 

Mohawk  Industries,  Inc.-  Lyerly  Plant 

1  A  A  1  C  £  A 

l 00 l 56-0 

T  1 

Lyerly 

GA 

Motorola  PPG  Compliance  Laboratory 

ZUUJ  1  o-U 

Boynton  Beach 

pi 

Motorola  Product  Quality  Assurance 

TAAAAC  A 

200005-0 

Mansfield 

IV  A  A 

MA 

Laboratory 

Motorola  so  l  u  cMU  l  tMrts  l  Laboratory 

1  C\C\A  AC  A 

1 UU4U5-0 

bcottsdale 

AZ 

Mountain  Laboratories 

1  A 1 COA  A 

Spokane 

AX/  A 

W  A 

lviv^o  inspection,  inc.  iviagneiic  ranicie  oc 

ZUUJ 14-U 

Santa  Fe  Springs 

f  A 
CA 

Liquid  Penetrant  Exam. 

MRS.,  Analytical  Laboratory,  Inc. 

1 A^ 1  1  ">  A 

1021 13-0 

Louisville 

KY 

Multifastener  Laboratory 

200267-0 

Taylor 

MI 

Muranaka  Environmental  Consultants,  Inc. 

102085-0 

Honolulu 

HI 

Mystic  Air  Quality  Consultants,  Inc. 

1 Ulzoz-U 

Groton 

L  1 

N 

NAHB  Research  Center,  Inc. 

1  A  A  1  A  ^  f\ 

100104-0 

Upper  Marlboro 

MD 

XT  A  C  A      T                   T-\                     1     g~\  , 

NASA-Lewis  Research  Center 

^  A  A  1  1  A  A 

200130-0 

Cleveland 

OH 

NATEC  International,  Inc. 

101 155-0 

Garden  Grove 

CA 

National  Analytical  Laboratories,  Inc. 

1  AT  A  OA  A 

102080-0 

Roseville 

CA 

National  Computing  Centre  Ltd. 

1  A  A3  C7  A 

10035  /-0 

Manchester 

UNI  1  blJ  1s.1N(jL)(JIV1 

National  Econ  Corporation 

1  AIA/O  A 

102062-0 

Tustin 

CA 

iNaiiondi  neon  corporation 

700047  0 
Z.\J\JVJH  1 -V) 

ivieiiipnib 

TO 

1  IN 

National  Environmental  Reference 

1  Al  A 

1015V3-0 

Denver 

tu 

Laboratory 

Naval  Dosimetry  Center 

i  00^04  n 

l UUJU4-U 

Bethesda 

1V1U 

Naval  Nuclear  Propulsion  Program 

1  A  A  C     C  A 

100565-0 

Bremerton 

Wl  A 

WA 

Directorate,  Washington,  D.C. 

INAWt  A1J  J.  1 .  / . j.  tlVll  LaD 

1 00408  0 

Patuxent  River 

1V1U 

in  a  WL.-Aircrait  uiv.  i_,aKenurst 

TAAT')')  A 

ZUUZZZ-U 

Lakehurst 

KI 1 

Diccuornagncuc  inicricrcncc  i^jd. 

IN  A  Wl  WrlNo  cMl  Lao,  cnina  LaKe/rt. 

TOO 1 QQ  O 

zuuiyy-u 

China  Lake 

C  A 
LA 

Mugu,  CA 

Nemko  EESI,  Inc. 

2001 16-0 

ban  Luego 

CA 

Neutron  Engineering  Inc. 

ZUU14D-U 

Taipei 

TA  1W  AM 
1  Al  WAIN 

New  York  Testing  Laboratories,  Inc. 

1  01  \V)  O 
1  U  1  JJZ-U 

Bay  Shore 

MV 
IN  I 

Newport  News  Shipbuilding  Radiological 

lOOSAl  O 
1 UUjO 1  -U 

Newport  News 

V  A 

V  A 

Control  Department 

NuL  lesting  services,  National  uypsum 

OAAOA1  A 

200zy 1-0 

rsuttalo 

N  Y 

Research  Center 

Niche  Analysis,  Inc. 

102057-0 

Mount  Vernon 

NY 

NJsP  Calibration  Laboratory 

OAAAA£  A 

200006-0 

Princeton 

XT  T 
NJ 

Northeast  Test  Consultants 

101565-0 

Westbrook 

Mb 

Northeast  Utilities  Dosimetry  Laboratory 

1  AAT  ^  A  A 

100540-0 

Newington 

C 1 

XT        *  1                 T"»     1                       T"\^  7T1  7  T  1 

Northern  Telecom  BVW  Lab 

1AAAAO  A 

200098-0 

Belleville,  Ontario 

/""■*  A  XT  AHA 

CANADA 

Northern  Telecom  Inc. 

1  AAil  1  1  f\ 

1 004 1 1 -0 

Santa  Clara 

CA 

XT          .1                    T>      1                           T~\             1            .     T       a                'a          T  1 

Northern  Telecom  Product  Integrity  Labs. 

1  A  A  ">  C  A  A 

l 00350-0 

Kanata  Ontario 

Z"1  A  XT  A  T~\  A 

CANADA 

Northern  Testing  Laboratories,  Inc. 

101463-0 

Fairbanks 

AK 

Northwest  EMC,  Inc. 

200059-0 

Newberg 

OR 

Northwest  Envirocon,  Inc. 

101869-0 

Vancouver 

WA 

NVLAP  1999  DIRECTORY  -  Page  A13  (See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  A.  LISTING  BY  LABORATORY  NAME  -  continued 


LABORATORY  NAME 

NVLAP 
LAB  CODE 

CITY 

STATE/ 
COUNT] 

Northwestern  Steel  and  Wire  Company 

200224-0 

Sterling 

IL 

Nova  Consulting  Group,  Inc. 

101545-0 

Chaska 

MN 

NOVA  Machine  Products 

200202-0 

Middleburg  Heights 

OH 

NSS  Technologies 

200184-0 

Plymouth 

Ml 

NVL  Laboratories,  Inc. 

102063-0 

Seattle 

WA 

NY  Environmental  &  Analytical  Labs,  Inc. 

101967-0 

Port  Washington 

NY 

NYLOK  Fastener  Corporation 

200272-0 

Anaheim 

CA 

NYLOK  Fastener  Corporation 

200273-0 

Macomb 

MI 

NYLOK  Fastener  Corporation  -  Chicago 

200275-0 

Lincolnwood 

IL 

Testing  Laboratory 

o 

0  &  K  Company  Limited,  Osaka  Test  Center 

200166-0 

Osaka-Shi 

JAPAN 

O'Brien  &  Gere  Laboratories,  Inc. 

101343-0 

Syracuse 

NY 

Oak  Ridge  Metrology  Center 

105000-0 

Oak  Ridge 

TN 

Oak  Ridge  National  Laboratory 

200228-0 

Oak  Ridge 

TN 

Oak  Ridge  National  Laboratory  Electric 

200244-0 

Oak  Ridge 

TN 

Machinery  Center 

OCCU-TEC,  Inc. 

102025-0 

Kansas  City 

MO 

Occupational  Health  Conservation,  Inc. 

102050-0 

Jacksonville 

FL 

Ohtama  Co.,  Ltd.  Yamanashi  EMC  Test  Site 

200175-0 

Yamanashi 

JAPAN 

Okai  Iron  Works  Co.,  Ltd. 

200299-0 

Izumisano  Osaka 

JAPAN 

Okawa  Laboratory 

200296-0 

Naka-gun,  Ibaraki-ken 

JAPAN 

Oklahoma  Dept.  of  Environmental 

102112-0 

Oklahoma  City 

OK 

Quality-State  Environmental  Lab 

Omni  Environmental,  Inc. 

102061-0 

Austin 

TX 

Orfield  Laboratories,  Inc. 

200248-0 

Minneapolis 

MN 

Osram  Sylvania  Inc.,  Test  &  Measurements 

100403-0 

Beverly 

MA 

Laboratory 

Owari  Precise  Products  Co.,  Ltd. 

200227-0 

Nagoya 

JAPAN 

Owens  Corning  Testing  Systems  -  Product 

100109-0 

Granville 

OH 

Testing  Laboratory 

P 

PA  DEP  Bureau  of  Laboratories 

101323-0 

Harrisburg 

PA 

Pace  Analytical 

101265-0 

Indianapolis 

IN 

Pacific  Environmental  Services,  Inc. 

101190-0 

Herndon 

VA 

Pacific  Gas  &  Electric  Company,  Diablo 

100537-0 

Avila  Beach 

CA 

Canyon  Nuclear  Power  Plant 

Pacific  Northwest  National  Laboratory 

105020-0 

Richland 

WA 

Pacific  Rim  Environmental,  Inc. 

101631-0 

Tukwila 

WA 

Paradyne  Corporation 

200125-0 

Largo 

FL 

Patriot  Environmental  Laboratory  Services 

200358-0 

Garden  Grove 

CA 

PB  Fasteners 

200139-0 

Gardena 

CA 

PBS  Environmental  Building  Consultants, 

101910-0 

Portland 

OR 

Inc. 

PCTEST  Engineering  Laboratory,  Inc. 

100431-0 

Columbia 

MD 

PDE  Laboratories 

200082-0 

San  Clemente 

CA 

PEP  Testing  Laboratory 

200097-0 

Taipei  Hsien 

TAIWAN 

PFS  Corporation 

100421-0 

Madison 

WI 

PFU  TECHNOCONSUL  EMC  Center 

200259-0 

Ishikawa-Ken 

JAPAN 

Philip  Analytical  Services 

101262-0 

Reading 

PA 

Philip  Environmental  Services  Corp. 

101192-0 

Columbia 

IL 

Philips  Electronics  Industries  (TAIWAN) 

200137-0 

Chungli,  Taoyuan 

TAIWAN 

NVLAP  1999  DIRECTORY  -  Page  A14 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  A.  LISTING  BY  LABORATORY  NAME  -  continued 


T  AROR  ATORY  NAME 

NVLAP 

T  AR  POflF 

PTTY 

V  1  X  X 

STATE/ 

Philips  Lighting  Corporate  Calibration  & 

100399-0 

Fairmont 

wv 

Standards  Laboratory 

< 

Pinchin  Environmental  Ltd. 

101270-0 

Mississauga  Ontario 

CANADA 

PMK  Group,  Inc. 

101301-0 

Kenilworth 

NJ 

Portland  Bolt  and  Manufacturing  Company, 

200168-0 

Portland 

OR 

Inc.  Testing  Laboratory 

PP&L,  Inc. 

100554-0 

Allentown 

PA 

Pratt  &  Whitney  Materials  Control 

200336-0 

East  Hartford 

CT 

Laboratory 

Precision  Micro- Analysis,  Inc. 

101656-0 

Sacramento 

CA 

Precision  Testing  Laboratories,  Inc. 

101580-0 

Moore 

OK 

Prezant  Associates,  Inc. 

101886-0 

Seattle 

WA 

PRIMES  (Preflight  Integration  of  Munitions 

100422-0 

Eglin  Air  Force  Base 

FL 

&  Electronic  Systems) 

Product  Safety  Engineering,  Inc. 

200074-0 

Dade  City 

FL 

Professional  Service  Industries,  Inc., 

100430-0 

Eugene 

OR 

Pittsburgh  Test.  Lab.  Div. 

Professional  Testing  (EMI),  Inc. 

200062-0 

Round  Rock 

TX 

Professional  Testing  Laboratory,  Inc. 

100297-0 

Dalton 

GA 

ProScience  Analytical  Services,  Inc. 

200090-0 

Woburn 

MA 

Prospect  Testing  Labs,  Inc. 

200328-0 

Des  Plaines 

IL 

Prottsa,  S.A.  de  C.V. 

200261-0 

Mexico  City 

MEXICO 

Proxtronics,  Inc. 

100573-0 

Burke 

VA 

PSI 

101342-0 

Lawrence 

KS 

PSI 

101350-0 

Pittsburgh 

PA 

PSI 

101755-0 

New  York 

NY 

PSI 

101970-0 

Brea 

CA 

PSI,  Inc. 

100319-0 

North  Haven 

CT 

PSI,  Inc. 

101070-0 

Farmingdale 

NY 

PSI,  Inc. 

200042-0 

New  Berlin 

WI 

Puget  Sound  Naval  Shipyard 

l 01 539-0 

Bremerton 

WA 

n 

QuanTEM  Laboratories,  LLC 

101959-0 

Oklahoma  City 

OK 

Queen  Carpet  Test  Laboratory 

l 00429-0 

Dalton 

GA 

Quest  Engineering  Solutions,  Inc. 

200036-0 

N.  Billerica 

MA 

Quest  MicroAnalytics,  Inc. 

200249-0 

Dallas 

TX 

Quietek  Corporation 

200347-0 

Hsin-Chu  City 

TAIWAN 

K 

R  &  B  Enterprises 

l 00280-0 

West  Conshohocken 

PA 

R&D  Services,  Inc. 

200265-0 

Cookeville 

TN 

R.  Robinson  Analytical  Services,  Inc. 

102041-0 

Pensacola 

FL 

Radiation  Detection  Company 

1  A  A  C  1  ^  A 

100512-0 

Sunnyvale 

CA 

Radiation  Laboratory,  Taiwan  Power 

100562-0 

Shihmen,  Taipei 

TAIWAN 

Company 

Radiation  Technology,  Inc. 

200086-0 

San  Jose 

CA 

Rapid  Environmental  Management,  Inc. 

101974-0 

Great  Neck 

NY 

Raytheon  Technical  Services  Co.  EMI 

200317-0 

Indianapolis 

IN 

Laboratory 

RCM  Laboratories,  Inc. 

101853-0 

Countryside 

IL 

Republic  Fastener  Manufacturing 

200195-0 

Newbury  Park 

CA 

Reservoirs  Environmental  Services,  Inc. 

101896-0 

Denver 

CO 

Reservoirs  Environmental  Services,  Inc. 

101896-1 

Houston 

TX 

Resources,  Applications,  Designs  &  Control, 

100261-0 

Long  Beach 

CA 

NVLAP  1999  DIRECTORY  -  Page  A15  (See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  A.  LISTING  BY  LABORATORY  NAME  -  continued 

NVLAP  STATE/ 

LABORATORY  NAME  LAB  CODE    CITY  COUNTRY 

Inc.  (RADCO) 

Retlif  Testing  Laboratories  100267-0  Ronkonkoma  NY 

Retlif  Testing  Laboratories  100267-1  Goffstown  NH 

Rhein  Tech  Laboratories,  Inc.  200061-0  Herndon  VA 

RheinTexas,  Inc.  200245-0  Piano  TX 

RI  Analytical  Laboratories,  Inc.  101440-0  Warwick  RI 

Rice  Lake  Weighing  Systems  105001-0  Rice  Lake  WI 

Ricoh  Company  LTD.  Ohmori  Acoustics  Test  200345-0  Tokyo  JAPAN 
Site 

Ricoh  Company,  Ltd.  Ohmori  EMC  Center      200163-0  Tokyo  JAPAN 

Rightway  Fasteners,  Inc.  200210-0  Columbus  IN 

Riverbank  Acoustical  Laboratories  100227-0  Geneva  IL 

RJ  Lee  Group,  Inc.  101208-0  Monroeville  PA 

RJ  Lee  Group,  Inc.  101208-2  San  Leandro  CA 

RJ  Lee  Group,  Inc.  101208-3  Manassas  VA 

RJ  Lee  Group,  Inc.  101208-5  Houston  TX 

Robbins  Manufacturing  Co.,  Inc.  200161-0  Fall  River  MA 

Rockford  Bolt  &  Steel  Co.  200255-0  Rockford  IL 

Rockford  Engineering  Services,  Inc.  200172-0  Sunol  CA 

Rocknel  Fastener  Inc.  200307-0  Rockford  IL 

Rogers  Labs,  Inc.  200087-0  Louisburg  KS 

Roy  F.  Weston,  Inc.  101254-0  Auburn  AL 

s 

S&ME,  Inc.  102075-0  Charlotte  NC 

Safe  Environment  of  America  102021-0  Kent  WA 

San  Shing  Hardware  Works  Co.,  Ltd.  Test  200158-0  Tainan  TAIWAN 
Laboratory 

Sandia  National  Laboratories  105002-0  Albuquerque  NM 

Sannohashi  Corporation  200205-0  Yashioshi,  Saitama-ken  JAPAN 

Saturn  Fasteners,  Inc.  200327-0  Burbank  CA 

Schneider  Laboratories,  Inc.  101150-0  Richmond  VA 

Scientific  Laboratories,  Inc.  101904-0  Midlothian  VA 

Scientific  Laboratories,  Inc.  101904-1  New  York  NY 

SCILAB  BOSTON,  Inc.  102079-0  East  Weymouth  MA 

SCILAB  California,  Inc.  200346-0  Carson  CA 

SEAS,  Inc.  101185-0  Blacksburg  VA 

Seiko  Epson  Corporation  200157-0  Shiojiri-City  Nagano  JAPAN 

Severn  Trent  Laboratories  (MA)  101005-0  N.  Billerica  MA 

SGI  EMC  Laboratories  200233-0  Mountain  View  CA 

SGS  U.S.  Testing  Company,  Inc.  100416-0  Tulsa  OK 

Shaw  Industries,  Inc.,  Central  Laboratory  100193-0  Dalton  GA 
Operations 

Small  IAC  Test  Laboratory  200287-0  Peterborough,  ON  CANADA 

SNB  Laboratory  200308-0  Cumberland  RI 

Solar  Environmental  Services,  Inc.  102006-0  Anchorage  AK 

Sony  Atsugi  EMC  Site  200285-0  Shinagawa,  Tokyo  JAPAN 

Sony  Electronics  Inc.  Product  Quality  200312-0  San  Diego  CA 
Division  EMC  Group 

Sony  Minokamo  EMC  Site  200368-0  Gifu-Pref.  JAPAN 

South  Carolina  Department  of  Health  &  101572-0  Columbia  SC 
Environmental  Control 

South  Coast  Air  Quality  Management  District    101567-0  Diamond  Bar  CA 

South  Texas  Project  Dosimetry  Laboratory       100519-0  Wadsworth  TX 

Southern  California  Edison  100506-0  San  Clemente  CA 

Southern  California  Edison  Company  105014-0  Westminster  CA 


NVLAP  1999  DIRECTORY  -  Page  A16 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  A.  LISTING  BY  LABORATORY  NAME  -  continued 


LABORATORY  NAME 


NVLAP 
LAB  CODE 


CITY 


STATE/ 
COUNTRY 


Special  Testing  Laboratories,  Inc.  100308-0 

Spectrum  Research  &  Testing  Laboratory,  200099-0 
Inc. 

Sporton  International,  Inc.  200079-0 

SPS  Technologies  Aerospace  Product  200298-0 
Division 

SPS  Technologies;  Aerospace  Fastener  Group  200164-0 

St.  of  California,  Bur.  of  Home  Furnishings  1 0025 1  -0 
&  Thermal  Insulation 

STAT  Analysis  Corporation  1 0 1 202-0 

State  of  Connecticut  101237-0 

State  of  Virginia  Metrology  Lab  1 05  007-0 

STERIS-Isomedix  Services  200235-0 

Steve  Moody  Micro  Services,  Inc.  102056-0 

Storagtek  Open  Area  Test  Site  20025 1  -0 

STS  Consultants,  Ltd.  1 00 1 9 1  -0 

Sugiura  Seisakusho  Co.,  Ltd.  200226-0 

Sumitomo  Metal  Technology,  Inc.  Kokura  200215-0 
Division 

Sun  City  Analytical,  Inc.  101 870-0 

Sun  Microsystems,  Inc.  EMC  Testing  200363-0 

Sundram  Fasteners  Limited  (Inhouse  test  200212-0 
laboratory) 

Sundram  Fasteners  Limited  Chemical  Testing  200256-0 
Laboratory 

Super  Cheng  Industrial  Testing  Laboratory  200280-0 


Bethel 

Chung-Li,  Taoyuan 

Taipei  Hsien 
Santa  Ana 

Jenkintown 
North  Highlands 

Chicago 

Hartford 

Richmond 

Whippany 

Carrollton 

Louisville 

Vernon  Hills 

Nishio  Aichi 

Kitakyushu 

El  Paso 
Palo  Alto 

Chennai  (Madras),  Tamil,  Nadh 
Andhra  Pradesh 
Kaohsiung,  Kangshan 


CT 

TAIWAN 

TAIWAN 
CA 

PA 

CA 

IL 

CT 

VA 

NJ 

TX 

CO 

IL 

JAPAN 
JAPAN 

TX 
CA 

INDIA 
INDIA 
TAIWAN 


Taiwan  Tokin  EMC  Eng.  Corp. 
TAO/TA2  EMC  Laboratory 
Taylor  Environmental  Group,  Inc. 
TC  Analytics,  Inc. 

TDK  Corporation's  1 0m  Anechoic  Chamber 

and  Chikumagawa  Open  Site 

TDK  Corporation's  Chikumagawa  Open  Site 

TEAC  Corporation  EMC  Center 

TEC-AN,  Inc. 

TEM,  Incorporated 

Tennessee  Valley  Authority  External 

Dosimetry  Service 

Test  Site  Services,  Inc. 

Test-Con  Incorporated 

Testing  Mechanics  Corp. 

Testwell  Laboratories,  Inc./Testwell 

Industries,  Inc. 

The  Monadnock  Company 

The  Perryman  Company 

The  Scott  Lawson  Group,  Ltd. 

Thomas  Lighting  Accent  Division 

Photometric  Laboratory 

Timberco,  Inc.-  dba  TECO 

Tokin  EMC  Engineering  Co.,  Ltd.  Kawasaki 

Facility 

Tokin  EMC  Engineering  Co.,  Ltd.  Nagoya 
Testing  Laboratory 


200077-0  Taipei  TAIWAN 

200140-0  Taoyuan  TAIWAN 

102101-0  Floral  Park  NY 

101672-0  Norfolk  VA 

200309-0  Ichikawa-shi,  Chiba-ken  JAPAN 

200319-0  Saku-shi,  Nagano-ken  JAPAN 

200362-0  Iruma-shi  JAPAN 

200325-0      .     Oklahoma  City  OK 

101130-0  GlenEllyn  IL 

100516-0  Soddy-Daisy  TN 

100419-  0  Marlboro  MA 
200018-0  Danbury  CT 
102001-0  Seaford  NY 
200083-0  Ossining  NY 

200268-0  City  of  Industry  CA 

200128-0  Houston  PA 

101228-0  Concord  NH 

200155-0  Los  Angeles  CA 

100420-  0  Eugene  OR 
200217-0  Kawasaki-city,  Kanagawa  JAPAN 

200219-0  Daian-cho,  Inabe-gun,  Mie  JAPAN 


NVLAP  1999  DIRECTORY  -  Page  A17 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  A.  LISTING  BY  LABORATORY  NAME  -  continued 


LABORATORY  NAME 


NVLAP 
LAB  CODE 


CITY 


STATE/ 
COUNTRY 


Tokin  EMC  Engineering  Co.,  Ltd.  Osaka  2002 1 8-0 
Testing  Laboratory 

Tokin  EMC  Engineering  Co.,  Ltd.  Tsukuba  200221-0 
Testing  Laboratory 

TolTest,  Inc.  101594-0 

TopuraCo.,  Ltd.  200181-0 

Topura  Co.,  Ltd.  Osaka  200242-0 

Topura  Co.,  Ltd.  Tokai  200243-0 

Toshiba  Corp.,  Ome  Works  200107-0 

Toshiba/Houston  Test  Laboratory  200088-0 

Training  Research  Co.,  Ltd.  200 1 74-0 

TRC  Environmental  Corporation  1 0 1 424-0 

Tremco,  Inc.  -  Roofing  Division,  An  RPM  101188-0 
Company 

Tri-State  Materials  Testing  Lab,  Inc.  2000 1 0-0 

Triad  Environmental  Consulting,  Inc.  102073-0 

Troxler  Radiation  Monitoring  Svc.  a  div.  of  100559-0 
Troxler  Elect.  Labs 

TSi,  Testing  Services,  Inc.  1 00 1 08-0 

TU  Electric-Comanche  Peak  Steam  Electric  1 00528-0 
Station 

TUV  Product  Service,  Inc.  1 00268-0 

TUV  Product  Service,  Inc.  1 0027 1  -0 

TUV  Product  Service,  Inc.  100271-1 

TUV  Rheinland  of  North  America,  Inc.  200 1 1 1  -0 

TUV  Telecom  Services,  Inc.  200039-0 

TWN  Fastener,  Inc.  200 1 94-0 

u 

U.S.  Army  Center  for  Health  Promotion  and  200044-0 
Preventive  Medicine 

U.S.  Army  Primary  Standards  Laboratory  105004-0 
U.S.  Army  Radiation  Standards  &  Dosimetry  100539-0 
Laboratory 

U.S.  EPA  200231-0 

U.S.  EPA  -  National  Enforcement  101703-0 
Investigations  Center 

UltraTech  Engineering  Labs  Inc.  200093-0 

Underwriters  Laboratories  200252-0 

Underwriters  Laboratories  Inc.  1 004 1 4-0 

Underwriters  Laboratories  Inc.  200214-0 

Underwriters  Laboratories,  Inc.  100255-0 

Underwriters  Laboratories,  Inc.  200246-0 

Union  Electric  Company,  Callaway  Plant  100502-0 

United  Analytical  Services,  Inc.  101732-0 

United  States  Dosimetry  Technology,  Inc.  1 005 7 1  -0 

United  States  Technologies,  Inc.  200 1 62-0 

United  Steel  and  Fasteners  Inc.  200341-0 

Universal  Compliance  Laboratories  2001 1 7-0 

University  (State)  Hygienic  Laboratory  101288-0 

University  of  Alabama  Asbestos  Laboratory  1 02005-0 
US  Air  Force  Center  for  Radiation  Dosimetry  100548-0 

USG  Research-Systems  Evaluation  200132-0 
Laboratory 


Sanda-city,  Hyogo  JAPAN 

Tsukuba-city,  Ibaraki  JAPAN 

Toledo  OH 

Hadano  Kanagawa  JAPAN 

Katano,  Osaka  JAPAN 

Ogasagun,Shizuoka  JAPAN 

Ome  Tokyo  JAPAN 

Houston  TX 

Taipei  TAIWAN 

Windsor  CT 

Beachwood  OH 

Newington  CT 

Huntington  WV 

Research  Triangle  Park  NC 

Dalton  GA 

Glen  Rose  TX 

San  Diego  CA 

New  Brighton  MN 

Boulder  CO 

Newtown  CT 

St.  Paul  MN 

Bowling  Green  KY 


Aberdeen  Proving  Ground  MD 

Redstone  Arsenal  AL 

Redstone  Arsenal  AL 

Las  Vegas  NV 

Denver  CO 

Mississauga,  Ontario  CANADA 

Santa  Clara  CA 

Northbrook  IL 

Camas  WA 

Melville  NY 

Research  Triangle  Park  NC 

Fulton  MO 

Hillside  IL 

Richland  WA 

Alpharetta  GA 

Itasca  IL 

San  Jose  CA 

Iowa  City  IA 

Tuscaloosa  AL 

Brooks  AFB  TX 

Libertyville  IL 


NVLAP  1999  DIRECTORY  -  Page  A18 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  A.  LISTING  BY  LABORATORY  NAME  -  continued 

NVLAP  STATE/ 
LABORATORY  NAME  LAB  CODE    CITY  COUNTRY 


V 


VallCbl  LdUUI  alUIlCi>, 

INCW   I  OIK 

IN  I 

Vermont  Fasteners  Manufacturing 

200254-0 

SI  wanton 

VT 

Vibro-Acoustics  Laboratory 

100424-0 

Slrarhoroiiijh  Ontario 

CANADA 

Volz  Environmental  Services  Inc. 

101269-0 

PifKbnrph 

PA 

Vulcan  Rivet  and  Bolt  Corporation 

200277-0 

Birmingham 

AL 

w 

W  R  Grace  &  Co 

200258-0 

f~1pinl"iriH  erf* 

MA 

Walker  Bolt  Manufacturing  Co. 

200126-0 

Houston 

TX 

VA7 cicninrrtr^n  T  Qnr\T"£itr*T"iPC    I  tri 
V  v  aM  1 1 1 1 g  i  Ul  1  LaUUlalUllCo,  LIU. 

I»  Q  l  f"n  prcnl  l  vcr 
VJaUIlClDULUg 

Wa^tf*  M^nacrpmpnt  FpHpfpiI  ^prvirfN  of 

10105R-0 

J  \  1  *,  1  1  1 1.1 1  1  u 

WA 

Hanford,  Inc. 

Water,  Earth  Solutions  &  Technologies,  Inc. 

1 UZU4J-U 

Danas 

TY 
1  A 

Wausau  Insurance  Companies 

1  n  i  mo  o 
i  u  i  u  /y-u 

Wausau 

WT 
WI 

w  dyne  j_.aiigoioii,  inc. 

900091  0 

LcdgUc  ^Iiy 

TY 
1  A 

Webber  Gage  Division  /  L.S.  Starred:  Co. 

200038-0 

Cleveland 

OH 

^A/p<;tpm  Analvtiral  1  ahoratorv 

200037-0 

Ri  irhanV 

LJ  Ul  UO.I  1 IV 

CA 

Western  Electro-Acoustic  Lab.  Inc. 

100256-0 

Santa  Monica 

CA 

White  Environmental  Consultants  Inc. 

200124-0 

Anchorage 

AK 

White  Environmental  Consultants,  Inc. 

200350-0 

Honolulu 

HI 

Willamette  Industries  Inc.  West  Coast 

200045-0 

Wilsonville 

OR 

lJsZ  VClUUIIlCIll  L^aU 

w  i ibon-vjarner  ^onipany 

9001 16  0 

Horn  CAn    1  n\i/nch  ir\ 

rial  I  laUIl  1  UVVIIMIIL) 

MI 

Windermere  Info.  Tech.  Sys. 

200084-0 

Annapolis 

MD 

Military/Commercial  Compliance  Lab. 

Wicrnncin  f^rTMrndtir^nctl  l-fpdltn  T  ctr\r\rQtr\r\/ 
VV  IsLUIlMIl  V-^CLUpallUIlal  Ocallll  l^aUUIalUiy 

1011 00-0 

\yf?tH  1  enn 

IVlcUJIoUl  1 

WI 

VV  I 

WKP  Laboratories,  Inc. 

101950-0 

Ossining 

NY 

Wolverine  Plating  Corp. 

200230-0 

Roseville 

MI 

Wonder  Makers  Environmental,  Inc. 

102065-0 

Kalamazoo 

MI 

World  Carpets,  Inc. 

100197-0 

Dalton 

GA 

Y 

Yamaha  Motor  Metal  Testing  Laboratory 

200276-0 

Iwata  Shizuoka 

JAPAN 

Fasteners  and  Metals 

z 

Zacta  Technology  Corporation  Yonezawa 

200306-0 

Yonezawa-shi  Yamagata 

JAPAN 

Testing  Center 


NVLAP  1999  DIRECTORY  -  Page  A19 


(See  'How  To  Use  This  Directory'  on  page  7.) 


♦ 


♦ 


♦ 


INDEX  B.  LISTING  BY  FIELD  OF  ACCREDITATION 
LABORATORY  NAME 


NVLAP 

LAB  CODE  CITY 


STATE/ 
COUNTRY 


CALIBRATION  LABORATORIES  GROUP 
Dimensional 

AlliedSignal  FM&T  Metrology  200108-0 

Lockheed  Martin  Idaho  Tech.  Co. ,  Standards  200 115-0 
and  Calibration  Lab. 

Lockheed  Martin  Technical  Operations  105017-0 

Metroplex  Metrology  Lab,  Inc.  200262-0 

Minnesota  Metrology  Laboratory  1 05003-0 

Oak  Ridge  Metrology  Center  1 05000-0 

Sandia  National  Laboratories  1 05002-0 

Southern  California  Edison  Company  105014-0 

State  of  Virginia  Metrology  Lab  1 05  007-0 

Webber  Gage  Division  /  L.S.  Starrett  Co.  200038-0 

Electromagnetics  -  DC/Low  Frequency 


Compaq  Corporate  Metrology 
Fluke  Corporation  Primary  Standards 
Laboratory 

GE  Industrial  Systems,  Renewal  Services  - 
TEMS 

Lockheed  Martin  Idaho  Tech.  Co.,  Standards 

and  Calibration  Lab. 

Lockheed  Martin  Technical  Operations 

Sandia  National  Laboratories 

Southern  California  Edison  Company 

U.S.  Army  Primary  Standards  Laboratory 

Electromagnetics  -  RF/Microwave 

Compaq  Corporate  Metrology 

Liberty  Labs,  Inc. 

Sandia  National  Laboratories 

U.S.  Army  Primary  Standards  Laboratory 

Ionizing  Radiation 

CDRH  X-Ray  Calibration  Laboratory 
Pacific  Northwest  National  Laboratory 
Sandia  National  Laboratories 
STERIS-Isomedix  Services 
U.S.  Army  Primary  Standards  Laboratory 

Mechanical 

AlliedSignal  FM&T  Metrology 
Denver  Instrument  Co.  Weight  Lab 
Henry  Troemner,  Inc. 
Instron  Force  Calibration  Laboratory 
Lockheed  Martin  Technical  Operations 
Minnesota  Metrology  Laboratory 
Rice  Lake  Weighing  Systems 
Sandia  National  Laboratories 
Southern  California  Edison  Company 
State  of  Virginia  Metrology  Lab 


200154-0 

105016-  0 

200029-0 
200115-0 

105017-  0 
105002-0 
105014-0 
105004-0 


200154-0 
200123-0 
105002-0 
105004-0 

105018-0 
105020-0 
105002-0 
200235-0 
105004-0 


200108-0 
200106-0 

105013-  0 
105023-0 
105017-0 
105003-0 

105001-  0 

105002-  0 

105014-  0 
105007-0 


Kansas  City 
Idaho  Falls 

Sunnyvale 
Fort  Worth 
St.  Paul 
Oak  Ridge 
Albuquerque 
Westminster 
Richmond 
Cleveland 


Houston 
Everett 

Rome 

Idaho  Falls 

Sunnyvale 
Albuquerque 
Westminster 
Redstone  Arsenal 


Houston 
Kimballton 
Albuquerque 
Redstone  Arsenal 


Rockville 
Richland 
Albuquerque 
Whippany 
Redstone  Arsenal 


Kansas  City 

Arvada 

Philadelphia 

Canton 

Sunnyvale 

St.  Paul 

Rice  Lake 

Albuquerque 

Westminster 

Richmond 


MO 
ID 

CA 
TX 
MN 
TN 
NM 
CA 
VA 
OH 

TX 
WA 

NY 

ID 

CA 
NM 
CA 
AL 


TX 
IA 
NM 
AL 


MD 

WA 

NM 

NJ 

AL 

MO 

CO 

PA 

MA 

CA 

MN 

WI 

NM 

CA 

VA 


NVLAP  1999  DIRECTORY  -  Page  B3 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  B.  LISTING  BY  FIELD  OF  ACCREDITATION  -  continued 


LABORATORY  NAME 


NVLAP 
LAB  CODE 


CITY 


STATE/ 
COUNTRY 


Optical  Radiation 

ILX  Lightwave  Corporation,  Optical 
Calibration 

Thermodynamic 

Fluke  Corporation  Primary  Standards 
Laboratory 

GE  Industrial  Systems,  Renewal  Services  - 
TEMS 

Lockheed  Martin  Technical  Operations 

Minnesota  Metrology  Laboratory 

Sandia  National  Laboratories 

State  of  Virginia  Metrology  Lab 

U.S.  Army  Primary  Standards  Laboratory 

Time  &  Frequency 

Compaq  Corporate  Metrology 
Fluke  Corporation  Primary  Standards 
Laboratory 

Lockheed  Martin  Idaho  Tech.  Co.,  Standards 

and  Calibration  Lab. 

Lockheed  Martin  Technical  Operations 

Sandia  National  Laboratories 

State  of  Virginia  Metrology  Lab 

U.S.  Army  Primary  Standards  Laboratory 


200211-0 


105016-  0 
200029-0 

105017-  0 

105003-  0 
105002-0 
105007-0 

105004-  0 

200154-0 

105016-  0 

200115-0 

105017-  0 
105002-0 
105007-0 
105004-0 


COMPUTER/ELECTRONICS  GROUP 
Cryptographic  Modules  Testing 

Cryptographic  Equipment  Assessment  Lab.  200002-0 
(CEAL) 

DOMUS  ITSL,  a  division  of  LGS  Group,  2000 1  7-0 
Incorporated 

InfoGard  Laboratories,  Inc.  1 00432-0 

GOSIP 

Control  Data  Accredited  OSI  Test  Center  1 00354-0 

National  Computing  Centre  Ltd.  1 00357-0 

Federal  Communications  Commission  (FCC) 

3M  Product  Safety  EMC  Laboratory  200033-0 

A-Pex  International  Co.,  Ltd.  Yokowa  200109-0 
Laboratory 

Advance  Data  Technology  Corporation  200 1 02-0 

AHD  200129-0 

Akzo  Kashima  Ltd.  Kakegawa  EMC  Test  Site  1 00290-2 

Akzo  Kashima  Ltd.,  Kashima  EMC  Site  1 00290-0 

Akzo  Kashima  Ltd.,  Kawasaki  Technical  200300-0 
Center 

Akzo  Kashima  Ltd.,  Matsuda  EMC  Test  Site  100290-4 

Akzo  Kashima  Ltd.,  Nagano  EMC  Test  Site  1 00290-3 

Akzo  Kashima  Ltd.,  Tochigi  EMC  Test  Site  1 00290-5 

Analab,  LLC  200260-0 

Apple  Computer,  Inc.,  EMC  Compliance  200071-0 


Bozeman 


Everett 

Rome 

Sunnyvale 
St.  Paul 
Albuquerque 
Richmond 
Redstone  Arsenal 

Houston 
Everett 

Idaho  Falls 

Sunnyvale 
Albuquerque 
Richmond 
Redstone  Arsenal 


McLean 
Ottawa  Ontario 
San  Luis  Obispo 

Arden  Hills 
Manchester 

Methods 

St.  Paul 
Mie-ken 

Taipei  Hsien 

Dowagiac 

Shizuoka 

Ibaraki 

Kawasaki 

Kanagawa 

Nagano 

Tochigi 

Sterling 

Cupertino 


MT 


WA 

NY 

CA 
MN 
NM 
VA 
AL 

TX 
WA 

ID 

CA 
NM 
VA 
AL 


VA 

CANADA 
CA 

MN 

UNITED  KINGDOM 

MN 
JAPAN 

TAIWAN 
MI 

JAPAN 
JAPAN 
JAPAN 

JAPAN 
JAPAN 
JAPAN 
PA 

CA 


NVLAP  1999  DIRECTORY  -  Page  B4 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  B.  LISTING  BY  FIELD  OF  ACCREDITATION  -  continued 


LABORATORY  NAME 


NVLAP 
LAB  CODE 


CITY 


STATE/ 
COUNTRY 


Laboratory 

AST  Research,  Inc.  EMC  Lab.  200135-0 

Bay  Area  Compliance  Laboratory,  Corp.  200167-0 

Cabletron  Systems,  Inc.  200121-0 

Canadian  Standards  Association  100322-0 

Celestica  International  Inc.  200055-0 

Chemitox  EMC  Research,  Inc .  200 1 20-0 

Chomencs  Test  Services  (CTS)  1 00296-0 

Cisco  Systems,  Inc.  200 1 1 4-0 

Communication  Certification  Laboratory  100272-0 

Compaq  Computer  Corp.  EMC  Test  Facility  200078-0 

Compaq  Computer  Corp.  Emissions  Control  200058-0 
Lab 

Compatible  Electronics,  Inc.  200063-0 

Compliance  Eng.  Svces,  Inc.,  Compliance  200065-0 
Certification  Services 

Compliance  Engineering  Services,  Inc.  -  200064-0 
Taiwan 

Compliance  Test  Laboratories,  Inc.  200237-0 

Cosmos  Corporation  200 151-0 

Criterion  Technology  100396-0 

Curtis-Straus  LLC  200057-0 

D.L.S.  Electronic  Systems,  Inc.  100276-0 

Data  General  Corporation  100339-0 

Dell  Regulatory  Test  Laboratories  200052-0 

Digital  Regulatory  Engineering  and  Testing  100413-0 
Services 

Diviersified  T.E.S.T.  Technologies,  Inc.  200340-0 

Eastman  Kodak  Co. -Regulatory  Compliance  200313-0 
Center-EMC  Facility 

Electro  Magnetic  Test,  Inc.  200 1 47-0 

Electro.  Meas.  Off,  Yokohama  Res.  &  Dev.  200263-0 
Ctr.  Murata  Mfg.  Co. 

Electronic  Compliance  Laboratories,  Inc.  200089-0 

Electronic  Research  &  Service  2001 1 8-0 
Organization/ITRI 

Electronics  Test  Centre  200282-0 

Electronics  Testing  Center,  Taiwan  200133-0 

Elite  Electronic  Engineering  Company  100278-0 

Elliott  Laboratories,  Inc.  200069-0 

EMC  Compliance  Mgmt  Group,  dba  200068-0 
Turntech  Scientific  &  Instr.,  Inc. 

EMC  International,  Inc.  200094-0 

EMC  Kashima  Corporation  200070-0 

EMCE  Engineering,  Inc.  200092-0 

Fountain  Compliance  Laboratory  200101-0 

Fujitsu  Evaluation  Engineering  Laboratory  200281-0 

Fujitsu  General  EMC  Laboratory  200373-0 

Garwood  Laboratories,  Inc.  200119-0 

Global  EMC  Standard  Tech.  Corp.  200085-0 

Hayes  Microcomputer  Products,  Inc.  200103-0 

Hewlett  Packard,  Product  Test  Lab,  San  200 1 3  8-0 


Irvine 

Sunnyvale 

Rochester 

Etobicoke  Ontario 

North  York,  Ontario 

Yamanashi-ken 

Woburn 

San  Jose 

Salt  Lake  City 

Colorado  Springs 

Houston 

Agoura 
Sunnyvale 

Sunnyvale 

Liberty 

Watarai-gun  Mie 

Rollinsville 

Littleton 

Wheeling 

Westboro 

Round  Rock 

Marlboro 

Groton 
Rochester 

Mountain  View 
Kanagawa 

Sunnyvale 
Hsinchu 

Kanata,  Ont. 
Taoyuan  Hsien 
Downers  Grove 
Sunnyvale 
Mountain  View 

Youngsville 
Chiba-ken 
Fremont 
Somerset 

Numazu,  Shizuoka-Pref. 

Kawasaki 

Placentia 

Taipei  County 

Atlanta 

San  Diego 


CA 
CA 
NH 

CANADA 

CANADA 

JAPAN 

MA 

CA 

UT 

CO 

TX 

CA 
CA 

CA 

SC 

JAPAN 

CO 

MA 

1L 

MA 

TX 

MA 

NY 
NY 

CA 

JAPAN 
CA 

TAIWAN 

CANADA 

TAIWAN 

IL 

CA 

CA 

NC 

JAPAN 

CA 

NJ 

JAPAN 
JAPAN 
CA 

TAIWAN 

GA 

CA 


NVLAP  1999  DIRECTORY  -  Page  B5 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  B.  LISTING  BY  FIELD  OF  ACCREDITATION  -  continued 


LABORATORY  NAME 


NVLAP 
LAB  CODE 


CITY 


STATE/ 
COUNTRY 


Diego 

Hitachi  Information  Technology  Co.,  Ltd.  2001 86-0 
Nakai  Test  Site 

HomeTek  Technology  Inc.  20033 1  -0 

IBM  Austin  EMC  200112-0 

IBM  Charlote  EMC  Facility  200337-0 

IBM  Rochester  EMC  Lab  20009 1  -0 

IBM  RTP  PSG  EMC  Test  Labs  200200-0 

IBM  Yamato  EMC  Engineering  200198-0 

InFocus  Systems,  Inc.  200152-0 

Instrument  Specialties  Co.,  Inc.  200076-0 

Integrity  Design  &  Test  Services,  Inc.  200004-0 

Intermec  Technologies  Corporation,  Norand  100269-0 
Mobile  System  Division 

International  Standards  Laboratory  200234-0 

Intertek  Testing  Services  200201-0 

Intertek  Testing  Services  N  A  Inc.  1 00270-0 

Intertek  Testing  Services  N A  Inc.  1 00274-0 

Intertek  Testing  Services  NA  Inc.  1 00409-0 

Intertek  Testing  Services  NA  Inc.  200297-0 

Intertek  Testing  Services  NA,  Inc.  200049-0 

IPS  Corporation  200012-0 

Japan  Quality  Assurance  Org.  Chubu  Testing  200190-0 
Center  Shikatsu  Branch 

Japan  Quality  Assurance  Org.  Safety  Testing  200192-0 
Ctr.  Tsuru  EMC  Branch 

Japan  Quality  Assurance  Organization  200191-0 
Kita-Kansai  Testing  Center 

Japan  Quality  Assurance  Organization  Safety  200189-0 
Testing  Center 

Kansai  Electronic  Industry  Development  200207-0 
Center,  Ikoma  Testing  Lab. 

Key  Tronic  Corp.  200096-0 

Korea  Tokin  EMC  Engineering  Co.,  Ltd.  200220-0 

KTL  Dallas,  Inc.  100426-0 

KTL  Ottawa  Inc.  100351-0 

LambdaMetncs,  Inc.  200122-0 

LG  Electronics,  Inc.,  Quality  and  Reliability  200040-0 
Center 

Lucent  Technologies,  Global  Product  100275-0 
Compliance  Lab 

Matsushita  EMC  Center  1 00428-0 

MET  Laboratories,  Inc.  100273-0 

Motorola  PPG  Compliance  Laboratory  2003 1 8-0 

Motorola  Product  Quality  Assurance  200005-0 
Laboratory 

Motorola  SSTG  EMC/TEMPEST  Laboratory  1 00405-0 

Nemko  EESI,  Inc.  200116-0 

Neutron  Engineering  Inc.  200145-0 

Northern  Telecom  BVW  Lab  200098-0 

Northern  Telecom  Inc.  100411-0 

Northern  Telecom  Product  Integrity  Labs.  100350-0 


Kanagawa  JAPAN 

Taipei  Shien  TAIWAN 

Austin  TX 

Charlotte  NC 

Rochester  MN 

Research  Triangle  Park  NC 

Yamato  Kanagawa  JAPAN 

Wilsonville  OR 

Delaware  Water  Gap  PA 

Littleton  MA 

Cedar  Rapids  IA 

Hsichih  Chen,  Taipei  TAIWAN 

Menlo  Park  CA 

Boxborough  MA 

Lexington  KY 

Norcross  GA 

Laguna  Niguel  CA 

Oakdale  MN 

Nagano  JAPAN 

Aichi  JAPAN 

Yamanashi  JAPAN 

Osaka  JAPAN 

Tokyo  JAPAN 

Ikoma  Nara  JAPAN 

Spokane  WA 

Namyangju-si,  Kyunggi-Do  KOREA 

Lewisville  TX 

Ottawa  Ontario  CANADA 

Cedar  Park  TX 

Seoul  KOREA 

Holmdel  NJ 

Taki-gun,  Hyogo  JAPAN 

Baltimore  MD 

Boynton  Beach  FL 

Mansfield  MA 

Scottsdale  AZ 

San  Diego  CA 

Taipei  TAIWAN 

Belleville,  Ontario  CANADA 

Santa  Clara  CA 

Kanata  Ontario  CANADA 


NVLAP  1999  DIRECTORY  -  Page  B6 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  B.  LISTING  BY  FIELD  OF  ACCREDITATION  -  continued 


T    \  O  AD  \  THDV  XT  V  A  TTT 

LAdUKA  1  UKl  JNA-Mt 

NVLAP 
LAh CODE 

CI  1  i 

STATE/ 
LUL.N  1  Ki 

Northwest  EMC,  Inc. 

200059-0 

Newberg 

OR 

Ohtama  Co.,  Ltd.  Yamanashi  EMC  Test  Site 

200175-0 

Yamanashi 

JAPAN 

Paradyne  Corporation 

200125-0 

Largo 

FL 

PCTEST  Engineering  Laboratory,  Inc. 

100431-0 

Columbia 

MD 

PDE  Laboratories 

200082-0 

San  Clemente 

CA 

PEP  Testing  Laboratory 

200097-0 

Taipei  Hsien 

TAIWAN 

PFU  TECHNOCONSUL  EMC  Center 

200259-0 

Ishikawa-Ken 

JAPAN 

Philips  Electronics  Industries  (TAIWAN) 

200137-0 

Chungli,  Taoyuan 

TAIWAN 

Ltd. 

Product  Safely  Engineering,  Inc. 

200074-0 

Dade  City 

FL 

Professional  Testing  (EMI),  Inc. 

200062-0 

Round  Rock 

TX 

Quest  Engineering  Solutions,  Inc. 

200036-0 

N.  Billerica 

MA 

Quietek  Corporation 

200347-0 

Hsin-Chu  City 

TAIWAN 

R  &  B  Enterprises 

100280-0 

West  Conshohocken 

PA 

Radiation  Technology,  Inc. 

200086-0 

San  Jose 

CA 

Retlif  Testing  Laboratories 

100267-0 

Ronkonkoma 

NY 

Retlif  Testing  Laboratories 

100267-1 

Goffstown 

NH 

Rhein  Tech  Laboratories,  Inc. 

200061-0 

Herndon 

VA 

RheinTexas,  Inc. 

200245-0 

Piano 

TX 

Ricoh  Company,  Ltd.  Ohmori  EMC  Center 

200163-0 

Tokyo 

JAPAN 

Rockford  Engineering  Services,  Inc. 

200172-0 

Sunol 

CA 

Rogers  Labs,  Inc. 

200087-0 

Louisburg 

KS 

Seiko  Epson  Corporation 

200157-0 

Shiojiri-City  Nagano 

JAPAN 

SGI  EMC  Laboratories 

200233-0 

Mountain  View 

CA 

Sony  Atsugi  EMC  Site 

200285-0 

Shinagawa,  Tokyo 

JAPAN 

Sony  Electronics  Inc.  Product  Quality 

200312-0 

San  Diego 

CA 

Division  EMC  Group 

Sony  Minokamo  EMC  Site 

200368-0 

Gifu-Pref. 

JAPAN 

Spectrum  Research  &  Testing  Laboratory, 
Inc. 

200099-0 

Chung-Li,  Taoyuan 

TAIWAN 

Sporton  International,  Inc. 

200079-0 

Taipei  Hsien 

TAIWAN 

Storagtek  Open  Area  Test  Site 

200251-0 

Louisville 

CO 

Sun  Microsystems,  Inc.  EMC  Testing 

200363-0 

Palo  Alto 

CA 

Taiwan  Tokin  EMC  Eng.  Corp. 

200077-0 

Taipei 

TAIWAN 

TAG7TA2  EMC  Laboratory 

200140-0 

Taoyuan 

TAIWAN 

TDK  Corporation's  1  Om  Anechoic  Chamber 

200309-0 

Ichikawa-shi,  Chiba-ken 

JAPAN 

and  Chikumagawa  Open  Site 

TDK  Corporation's  Chikumagawa  Open  Site 

200319-0 

Saku-shi,  Nagano-ken 

JAPAN 

TEAC  Corporation  EMC  Center 

200362-0 

Iruma-shi 

JAPAN 

Test  Site  Serv  ices,  Inc. 

100419-0 

Marlboro 

MA 

Tokin  EMC  Engineering  Co.,  Ltd.  Kawasaki 

200217-0 

Kawasaki-city,  Kanagawa 

JAPAN 

Facility 

Tokin  EMC  Engineering  Co.,  Ltd.  Nagoya 

200219-0 

Daian-cho,  Inabe-gun,  Mie 

JAPAN 

Testing  Laboratory 

Tokin  EMC  Engineering  Co.,  Ltd.  Osaka 

200218-0 

Sanda-city,  Hyogo 

JAPAN 

Testing  Laboratory 

Tokin  EMC  Engineering  Co.,  Ltd.  Tsukuba 

200221-0 

Tsukuba-city,  Ibaraki 

JAPAN 

Testing  Laboratory 

Toshiba  Corp.,  Ome  Works 

200107-0 

Ome  Tokyo 

JAPAN 

Training  Research  Co.,  Ltd. 

200174-0 

Taipei 

TAIWAN 

TUV  Product  Service,  Inc. 

100268-0 

San  Diego 

CA 

TUV  Product  Sendee,  Inc. 

100271-0 

New  Brighton 

MN 

NVLAP  1999  DIRECTORY  -  Page  B7 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  B.  LISTING  BY  FIELD  OF  ACCREDITATION  -  continued 


LABORATORY  NAME 

NVLAP 
LAB  CODE 

CITY 

STATE/ 
rOTINTRY 

TI  \\f  PtTiHmpI"  ^pruirp  Inr 

1  kJ  V    ^lVJUUCL  OC1  V  ILt, 

100971  1 

l  \jyjjL  1  1  -  1 

I-<  f\i  1 1  or 

oouiuer 

1  \J  V   I\11L  IllldllU  Ul  1NUI  III  rVIIltl  ILd,  1I1L. 

9001 1 1  0 
ZWU  111  -\) 

Newtown 

L- 1 

\  l\/  Tplppnm  NPn/irpc  Inp 

1  U  V     1  C  IICUI 1 1  OCI  V  ItCd,  11  It. 

9000^0  0 

Cf  Paul 
ol.  rdUl 

IV- 1 1  -J 

T  Tlrro  1  ppn  Htimnpprinn  T  one  Inr 
UllfalClU  CllglllCCI  III     LdUb  1I1C 

9onocn  o 

Mississauga,  Ontario 

C  A  M  A  F>  A 

vJHUCI  WI  11CI  o  LdUUI  alUI  Ito 

9009^9  0 

Santa  Clara 

f~  A 

UI1UCI  WI  Iltl  o  LdUUI  dlUI  ICo  1I1C 

1 00A1 A  0 

Northbrook 

Tt 

IL 

vJIlUCI  WI  11CI  o  LaUUI  alUI  Ito  1I1L. 

9009 1  A  0 

Camas 

W  A 

\J  IIUCI  Wl  1  LCI  b  LaUUlalUI  Itb,  IIIL. 

1  009  ^^s  0 

ivieiviiie 

iN  » 

UI1UCI  Wl  UCI  b  L^auOidlUl  ICS,  int. 

9009A£  0 

Research  Triangle  Park 

INL, 

T  ImtpH  ^tatpc  Tpphnnlncnpc  Tr>p 

9001 fi?-0 

/\ipilal  Clla 

OA 

I  Imvprcal  Pnmnlianrp  T  ahnrafnripc 

Ulll  V  tl  oal  v_  KJ 1  !  1 l )  1 1  Ul  \  \.\.  L->tlULMclHJiICo 

9001 1 7-0 

/.UU  11/  ~w 

von  Tr\cp 

^A 

Washington  I  ahoratones  T  trl 

C~t  ^  1 1  h  p  r  c  h  i  i  r  o 

V_l  ClI  111 tl  oUUlg 

Waynp  T  ancrctnn  Inp 
vv  ci y  ul  Lcii i iu 1 1 ,  HIV.'. 

7000? 1-0 

T  PQCTI1P  C~^lt\/ 

LCdguc  v_.uy 

TV 

1  A 

Windermere  Info.  Tech.  Sys. 

200084-0 

Annapolis 

MD 

Military/Commercial  Compliance  Lab. 

Zacta  Technology  Corporation  Yonezawa 

200306-0 

Yonezawa-shi  Yamagata 

JAPAN 

Testing  Center 

MIL-STD-462  Test  Methods 

A  ptf\n  Pnvi rnnmpntQi  T'pcti n rr    HnQ  M  oti c\v\ q  1 
AtlUIl  CIl V 11  UUIIlCIllal   1  CMlUg,  UUa  INaLlUIlal 

1  Ul/JT  /  -O 

do  a  Dorougti 

AA  A 

Tp/'nn  i  p  q  1  \\/ctpm  c 
ICLIlIllCal  oyblclllo 

CalUIl  CJ  \-,a  UU I  a  I  Ul  y 

oouLiiiieiu 

M  I 
IV!  1 

Flitp  Plpr'trnnip  Pnompprinrr  i  c\ m mn\/ 
IjIilc  i_.itcii  uiiil-  Ljiigiiicci  nifi  v_uiiiuany 

1 00778-0 

L/UWllCIo  UlUVt 

1 1 

1  L 

(IpP  NyT q rprxm  Avip.nipc  T  tH  Pn\/irrin m n  r  q  1 
VJCV^  IVldlLUIll  /WlUIllCo  LIU.  Lll  VII  UIllIlCllLal 

700^04  0 

PvCIU 

and  EMC  Test  Center 

TntprtpL'  Tpctino  ^prv/ifpc  TSJ  A  Inp 
111LC1  IC1S.   1  CM1I1X  Oil  VKCo  I N  r\  lllv. 

1 00^70  0 

DUX  UUI  UUgll 

MA 
lvl/\ 

1    r\pl/n£ipn   N/loftin  1    /"\ni"i-r\l    K  \  /  o  1    m  o  In  \/TT 

LUCKiiceu  ividniii  v^oinroi  oysierns  nivii 

9 on  1 49  0 

Johnson  City 

MV 
IN  I 

Laboratory 

Mntnmla  QCTfi  FIV/f  P/TFIVf  PF<sT  T  aknt  Qtr\r\/ 

ivioioroia  jo  i  \j  civiw 1  civir  r_,o  i  Lduoi  diory 

1 0040 S  0 

Scottsdale 

A  7 
AZ. 

lN/\  VV      r\VJ  J .  1 .  /  .J.  Civil  L,dO 

1 00408  0 

Patuxent  River 

1V11J 

INA.  VV  l^-/\irL.ldll  Ul\.  LvdrvcnUlbl 

900999  0 

Lakehurst 

1>  J 

P  I  pptT"pim  Qn,npti/,%  In  fp  i"TPrpn  c  &  T  on 
C1CCU  UIIldgllCLlC  1 11  lei  1CI  LHvC  LaU. 

NAWCWPNS  FN/TT  I  ah  China  T  akp/Pt 

9001 00-0 

I  I  Mil. 1  LvarvC 

PA 

rVInaii  CA 

PRIMF'n  ("Prpflioht  Intparation  of  Mnnifions 

1  XVJIIV11_,0  ^riClllUlll  lllLCgl  aliUll  Ul  1V1  Ul  1 1  LIUllo 

1 00499-0 

Pfrlm  Air  Pnrpp  Rqcp 
JDgUII  AV1I  rUICC  Daot 

Ft 

&  Flpctrnnic  ^VstpmO 

W  sir  R  Pn  fprnn  c  c*c 
iv  Oc  13  ClliCIUIlbCo 

1 009S0  0 

vv  esi  v^,unsnoriucK.en 

r  A 

JtvayillcUil  1  tCillllLdl  Otl  Vltco  v.U.  JZ-lvll 

9001 1 7  0 

Indianapolis 

1  IN 

Laboratory 

Retlif  Testing  Laboratories 

100267-0 

Ronkonkoma 

NY 

TUV  Product  Service,  Inc. 

100268-0 

San  Diego 

CA 

TUV  Product  Service,  Inc. 

100271-0 

New  Brighton 

MN 

DOSIMETRY  GROUP 

Ionizing  Radiation  Dosimetry 

/\I  IZUIld  rUUllC  oeivlLc  V^u.,  ralU  V  clUt 

1  00S1^>  0 

jl  oiiupdn 

Kliirlpir  Opnpr^t  i  n  i  r  Q t q t i  r\n 
IN  utlttll   VJCllCldllllg  OLdllUlI 

Atomic  Energy  Industrial  Laboratory  of  the 

1 UUj jO-U 

Houston 

TY 
i  A 

^niitn\x/pct  Inp 
OUUlll  WCol,  JI1L. 

Baltimore  Gas  &  Electric  Company 

100501-0 

Lusby 

MD 

Battelle  -  Pacific  Northwest  National 

200216-0 

Richland 

WA 

Laboratory 

Carolina  Power  &  Light  Company,  Harris 

100517-0 

New  Hill 

NC 

NVLAP  1999  DIRECTORY  -  Page  B8 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  B.  LISTING  BY  FIELD  OF  ACCREDITATION  -  continued 


LABORATORY  NAME 


NVLAP 
LAB  CODE 


CITY 


STATE/ 
COUNTRY 


Energy  &  Enviro.  Center 

Clinton  Power  Station  1 005  70-0 

Combustion  Engineering,  Inc.  100563-0 

ComEd  -  TLD  Processing  Lab  -  CTEAM  1 0054 1  -0 
Facility 

Con  Edison,  Indian  Point  1 0053 8-0 

Detroit  Edison,  Fermi  2  Dosimetry  1 00529-0 
Laboratory 

Duke  Engineering  and  Services  100524-0 
Environmental  Laboratory 

Duke  Power  Company  Dosimetry  Laboratory  100505-0 

Duquesne  Light  Company,  Beaver  Valley  100521-0 
Power  Station 

Eberline  Dosimetry  Service  100515-0 

Electric  Boat  Corp/A  General  Dynamics  Co.  100560-0 
Radiological  Ctrl.  Dept 

Entergy  Operations,  Inc.  1 005  3  5  -0 

Florida  Power  &  Light  Company  1 00544-0 

Georgia  Power  Company/Enviro.  Affairs,  100551-0 
Enviro.  Lab-Dosimetry 

Ginna  Nuclear  Station  1 005 1 4-0 

GPU  Nuclear  Corp.  100510-0 

HPNW  100567-0 

ICN  Dosimetry  Service,  Div.  of  ICN  1 00555-0 
Biomedicals,  Inc. 

Landauer,  Inc.  100518-0 

Mallinckrodt  Group,  Inc.  1 00503-0 

Naval  Dosimetry  Center  1 00504-0 

Naval  Nuclear  Propulsion  Program  100565-0 
Directorate,  Washington,  D.C. 

Newport  News  Shipbuilding  Radiological  100561-0 
Control  Department 

NJSP  Calibration  Laboratory  200006-0 

Northeast  Utilities  Dosimetry  Laboratory  100540-0 

Pacific  Gas  &  Electric  Company,  Diablo  100537-0 
Canyon  Nuclear  Power  Plant 

PP&L,  Inc.  100554-0 

Proxtronics,  Inc.  100573-0 

Radiation  Detection  Company  1 005 1 2-0 

Radiation  Laboratory,  Taiwan  Power  100562-0 
Company 

South  Texas  Project  Dosimetry  Laboratory  1005 1 9-0 

Southern  California  Edison  100506-0 

Tennessee  Valley  Authority  External  1 005 1 6-0 
Dosimetry  Service 

Troxler  Radiation  Monitoring  Svc.  a  div.  of  100559-0 
Troxler  Elect.  Labs 

TU  Electric-Comanche  Peak  Steam  Electric  1 00528-0 
Station 

U.S.  Army  Radiation  Standards  &  Dosimetry  100539-0 
Laboratory 

U.S.  EPA  200231-0 


Clinton 

Windsor 

Bolingbrook 

Buchanan 
Newport 

Bolton 

Charlotte 
Shippingport 

Albuquerque 
Groton 

Taft 

Juno  Beach 
Smyrna 

Ontario 
Middletown 
Tigard 
Costa  Mesa 

Glenwood 
Maryland  Heights 
Bethesda 
Bremerton 

Newport  News 

Princeton 
Newington 
Avila  Beach 

Allentown 
Burke 
Sunnyvale 
Shihmen,  Taipei 

Wadsworth 
San  Clemente 
Soddy-Daisy 

Research  Triangle  Park 

Glen  Rose 

Redstone  Arsenal 

Las  Vegas 


IL 

CT 

IL 

NY 
MI 

MA 

NC 
PA 

NM 
CT 

LA 
FL 
GA 

NY 
PA 
OR 
CA 

IL 

MO 
MD 
WA 

VA 

NJ 
CT 
CA 

PA 
VA 
CA 

TAIWAN 

TX 
CA 
TN 

NC 

TX 

AL 

NV 


NVLAP  1999  DIRECTORY  -  Page  B9 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  B.  LISTING  BY  FIELD  OF  ACCREDITATION  -  continued 


NVLAP 

STATE/ 

LABORATORY  NAME 

LAB  CODE 

CITY 

COUNTRY 

Union  Electric  Company,  Callaway  Plant 

100502-0 

Fulton 

MO 

United  States  Dosimetry  Technology,  Inc. 

100571-0 

Richland 

WA 

US  Air  Force  Center  for  Radiation  Dosimetry 

100548-0 

Brooks  AFB 

TX 

ENVIRONMENTAL  GROUP 

Asbestos  Fiber  Analysis  (PLM  Test  Method) 

A  &  B  Environmental  Services,  Inc. 

101793-0 

Houston 

TX 

A  T  Labs 

101062-0 

Youngstown 

OH 

A.E.S.L. 

200303-0 

Tempe 

AZ 

A.R.C.  Laboratories,  Inc. 

101832-0 

Grand  Forks 

ND 

AAC  Trinity,  Inc. 

101168-0 

Farmington  Hills 

MI 

ABM  Environmental  Consultants,  Inc. 

102015-0 

Long  Island  City 

NY 

Accredited  Environmental  Technologies,  Inc. 

101051-0 

Media 

PA 

Accredited  Environmental  Technologies,  Inc. 

200236-0 

Leland 

NC 

ACM  Environmental,  Inc. 

101977-0 

South  Bend 

IN 

Advanced  Industrial  Hygiene  Services,  Inc. 

101006-0 

Miami 

FL 

AGRA  Earth  and  Environmental,  Inc.  -  Env. 

200357-0 

Portland 

OR 

Chemistry  Laboratory 

AGX,  Inc. 

101578-0 

Cranberry  Township 

PA 

Aires  Consulting  Group,  Inc. 

101014-0 

Batavia 

IL 

AIResearch,  Inc. 

101868-0 

Wauwatosa 

WI 

Airtek  Environmental  Corp. 

102011-0 

New  York 

NY 

ALAC 

200323-0 

Bronx 

NY 

Allegheny  Asbestos  Analysis 

101704-0 

Carnegie 

PA 

Alpine  Consulting,  Inc. 

102089-0 

Colorado  Springs 

CO 

AMA  Analytical  Services,  Inc. 

101 143-0 

Lanham 

MD 

Ambient  Labs,  Inc. 

101618-0 

New  York 

NY 

American  Asbestos  Laboratories,  Inc. 

101775-0 

Miami 

FL 

American  Electric  Power,  Environmental 

102102-0 

Columbus 

OH 

Laboratory 

American  Medical  Laboratories,  Inc. 

101136-0 

Chantilly 

VA 

Analytica  Solutions,  Inc. 

101086-0 

Broomfield 

CO 

Analytical  Environmental  Services 

OflftfK  1  f\ 
ZUUUj 1  -U 

Hato  Rey 

PR 

International,  Inc. 

Analytical  Environmental  Services,  Inc. 

102033-0 

Atlanta 

GA 

Analytical  Industries,  Inc. 

101855-0 

Paducah 

KY 

Analytical  Labs  San  Francisco,  Inc. 

101909-0 

San  Francisco 

CA 

Analyticalab 

101727-0 

Willow  Springs 

IL 

Apex  Research  Laboratory 

102118-0 

Whitmore  Lake 

MI 

Apollo  Environmental,  Inc. 

101871-0 

Gibsonton 

FL 

Applied  Environmental,  Inc. 

101611-0 

Reston 

VA 

ASBESTECH 

101442-0 

Carmichael 

CA 

Asbestos  Analysis  and  Information  Service, 
Inc. 

101261-0 

Four  Oaks 

NC 

Asbestos  Analytical 

101771-0 

Tucson 

AZ 

Asbestos  Consulting  &  Testing  (ACT) 

101649-0 

Lenexa 

KS 

Asbestos  TEM  Laboratories,  Inc. 

101891-0 

Berkeley 

CA 

Asbestos  TEM  Laboratories,  Inc. 

200104-0 

Sparks 

NV 

Assaigai  Analytical  Laboratories,  Inc. 

101457-0 

Albuquerque 

NM 

ATC  Associates  Inc. 

102071-0 

Cincinnati 

OH 

ATC  Associates  Inc. 

200250-0 

Columbia 

MD 

ATC  Associates  Inc. 

200290-0 

Dallas 

TX 

NVLAP  1999  DIRECTORY  -  Page  B10  (See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  B.  LISTING  BY  FIELD  OF  ACCREDITATION  -  continued 

NVLAP  STATE/ 

LABORATORY  NAME  LAB  CODE  CITY  COUNTRY 

ATC  Associates,  Inc.  101187-0  New  York  NY 

ATC  Environmental,  Inc.  102031-0  Englewood  CO 

Athenica  Environmental  Services,  Inc.  101958-0  Long  Island  City  NY 

Aurora  Consolidated  Laboratories  101661-0  West  Allis  WI 

Austin  Analytical  Laboratory  200014-0  Austin  TX 

Batta  Laboratories,  Inc.  101032-0  Newark  DE 

Bay  Area  Air  Quality  Management  District  102090-0  San  Francisco  CA 

Beling  Consultants,  Inc.  101356-0  Moline  IL 

Bell  Laboratories,  Division  Lucent  101965-0  Murray  Hill  NJ 
Technologies,  Inc. 

Braun  Intertec  Corporation  101234-0  Minneapolis  MN 

CAM  Environmental  Services,  Inc.  200240-0  Pasadena  TX 

CAMCOLab  101803-0  Fontana  CA 

Cape  Environmental  Management,  Inc.  102111-0  Atlanta  GA 

Carnow,  Conibear  &  Associates  Ltd.  101039-0  Chicago  IL 

Carolina  Environmental,  Inc.  101768-0  Cary  NC 

Chatfield  Technical  Consulting  Limited  101103-0  Mississauga  Ontario  CANADA 

ChemScope,  Inc.  101061-0  North  Haven  CT 

CHEMTEX  Environmental  Laboratory,  Inc.  200025-0  Port  Arthur  TX 

Chopra-Lee,  Inc.  200095-0  Grand  Island  NY 

City  of  Los  Angeles  Department  of  Water  101111-0  Los  Angeles  CA 
and  Power 

Clark  Seif  Clark,  Inc.  200324-0  Chatsworth  CA 

Clayton  Environmental  Consultants  101106-0  Seattle  WA 

Clayton  Laboratory  Services  101125-0  Kennesaw  GA 

Comprehensive  Health  101759-0  Kennedy  Space  Center  FL 
Services-Environmental  Health  PLM 
Laboratory 

Con  Edison  -  ChemLab  101558-0  Long  Island  City  NY 

Concord  Analysis,  Inc.  101884-0  Chatsworth  CA 

Continental  Envirotech,  Inc.  200080-0  Mesa  AZ 

Converse  Consultants  MR,  Inc.  102091-0  Reno  NV 

Covino  Environmental  Associates,  Inc.  101781-0  Woburn  MA 

Craig  Environmental  Services,  Inc.  200289-0  Mays  Landing  NJ 

Crisp  Analytical  Laboratory  200349-0  Carrollton  TX 

Criterion  Laboratories,  Inc.  102046-0  Bensalem  PA 

CT&E  Environmental  Services  Inc.  200067-0  San  Diego  CA 

CTL  Environmental  Services  101216-0  Harbor  City  CA 

Dames  &  Moore,  Inc.  101433-0  Salem  NH 

DataChem  Laboratories  101917-0  Cincinnati  OH 

Davis  &  Floyd,  Inc.  101410-0  Greenwood  SC 

DCM  Science  Laboratory,  Inc.  101258-0  Wheat  Ridge  CO 

Department  of  Environmental  Health  101530-0  San  Diego  CA 
Industrial  Hygiene  Laboratory 

Design  for  Health,  Inc.  101864-0  San  Diego  CA 

DHMH-Air  Quality  Laboratory  101523-0  Baltimore  MD 

Dixon  Information  Inc.  101012-0  South  Salt  Lake  UT 

DLZ  Laboratories,  Inc.  101060-0  Columbus  OH 

Dolphin  Environmental  Consultants  1 02086-0  Stafford  TX 

Dove  Environmental  Corporation  1 02053-0  Miami  FL 

EA  Group  101019-0  Mentor  OH 

EAI,  Inc.  102114-0  Jersey  City  NJ 


NVLAP  1999  DIRECTORY  -  Page  Bll 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  B.  LISTING  BY  FIELD  OF  ACCREDITATION  -  continued 


LABORATORY  NAME 

NVT  AP 
LAB  CODE 

CITY 

COUNTRY 

Eastern  Analytical  Services,  Inc. 

101646-0 

Elmsford 

NY 

EcoSystems  Environmental,  Inc. 

101162-0 

Carrollton 

TX 

ECS/Wagner  Environmental 

101064-0 

Eugene 

OR 

EEC,  Inc. 

101088-0 

Raleigh 

NC 

EMS  Laboratories,  Inc. 

101218-0 

Pasadena 

CA 

EMSL  Analytical  Mobile  Laboratory 

200344-0 

Chicago 

IL 

EMSL  Analytical,  Inc. 

101048-0 

Westmont 

NJ 

EMSL  Analytical,  Inc. 

101048-1 

Atlanta 

GA 

EMSL  Analytical,  Inc. 

101048-2 

Piscataway 

NJ 

EMSL  Analytical,  Inc. 

101048-3 

San  Mateo 

CA 

EMSL  Analytical,  Inc. 

101048-4 

Ann  Arbor 

MI 

EMSL  Analytical,  Inc. 

101048-9 

New  York 

NY 

EMSL  Analytical,  Inc. 

101048-10 

Carle  Place 

NY 

EMSL  Analytical,  Inc. 

101277-0 

Fairfax 

VA 

EMSL  Analytical,  Inc. 

102104-0 

Greensboro 

NC 

EMSL  Analytical,  Inc. 

102105-0 

Warwick 

R] 

EMSL  Analytical,  Inc. 

102106-0 

Houston 

TX 

EMSL  Analytical,  Inc. 

200019-0 

Seattle 

WA 

EMSL  Analytical,  Inc. 

200034-0 

Dallas 

TX 

EMSL  Analytical,  Inc. 

200056-0 

Williamsville 

NY 

EMSL  Analytical,  Inc. 

200188-0 

Indianapolis 

IN 

EMSL  Analytical,  Inc. 

200204-0 

N.  Miami  Beach 

FL 

EMSL  Analytical,  Inc. 

200247-0 

Charlotte 

NC 

EMSL  Analytical,  Inc. 

200293-0 

Beltsville 

MD 

EMSL  Analytical,  Inc. 

200310-0 

Carlstadt 

NJ 

EMSL  Analytical,  Inc. 

200333-0 

Elmsford 

NY 

EMSL  Analytical,  Inc. 

200375-0 

Baton  Rouge 

LA 

ENCORP 

200013-0 

El  Segundo 

CA 

Enviro  Techniques,  Inc. 

200024-0 

Paterson 

NJ 

Enviro-Probe,  Inc. 

101222-0 

Bronx 

NY 

EnviroHealth  Technologies,  Inc. 

200374-0 

St.  Louis 

MO 

EnviroMed  Services,  Inc. 

101514-0 

New  Haven 

CT 

Environmental  Enterprise  Group(EEG),  Inc. 

101587-0 

Russellville 

AR 

Environmental  Hazards  Services,  L.L.C. 

101882-0 

Richmond 

VA 

Environmental  Health  Laboratories 

101506-0 

Clayton 

MO 

Environmental  Management  Consultants,  Inc. 

101926-0 

Scottsdale 

AZ 

Environmental  Monitoring  &  Consulting 

101087-0 

Somerville 

NJ 

Associates 

Environmental  Services  International,  Inc. 

101306-0 

St.  Albans 

WV 

Environmental  Testing  and  Monitoring 

200131-0 

Virginia  Beach 

VA 

Services,  Inc. 

Environmental  Testing,  Inc. 

101848-0 

Middletown 

DE 

EnvironMETeo  Services  Inc. 

101807-0 

Waipahu 

HI 

Envirotest,  Inc. 

101595-0 

Houston 

TX 

ERI  Consulting  Engineers,  Inc. 

101232-0 

Tyler 

TX 

ERT  Testing  Services 

101295-0 

Highland  Park 

VII 

ESG  Laboratories 

102029-0 

Indianapolis 

IN 

EssTek  Ohio,  Inc. 

102093-0 

Middleburg  Heights 

OH 

Fiberquant,  Inc. 

101031-0 

Phoenix 

AZ 

Fibertec,  Inc. 

101510-0 

Holt 

MI 

Fluor  Daniel  Fernald,  Inc.,  Analytical 

102010-0 

Cincinnati 

OH 

Laboratory  Services 


NVLAP  1999  DIRECTORY  -  Page  B12 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  B.  LISTING  BY  FIELD  OF  ACCREDITATION  -  continued 


LABORATORY  NAME 


NVLAP 
LAB  CODE 


CITY 


STATE/ 
COUNTRY 


Forensic  Analytical  Specialties,  Inc.  101459-0 

Forensic  Analytical  Specialties,  Inc.  101459-1 

Froehling  &  Robertson,  Inc.  1 02060-0 

FRS  Geotech,  Inc.  102078-0 

GA  Environmental  Services.  Inc.  101996-0 

Galson  Laboratories  101375-0 

Gelles  Laboratories,  Inc.  101170-0 

Geo- Analytical  Services,  Inc.  102082-0 

GLE  Associates,  Inc.  1 02003-0 

GPU  Nuclear  Chemistry/Materials  Labs.  1 02064-0 

Guardian  Laboratories  1 0 1399-0 

Health  Science  Associates  101384-0 

Henderson/Longfellow  Associates,  Inc.  102077-0 

Hi-Tech  Environmental  and  Laboratory  102013-0 
Services 

HIH  Laboratory,  Inc.  101233-0 

Hillmann  Environmental  Company  101421-0 

Hub  Testing  Laboratory,  Inc.  101045-0 

Hygeia  Laboratories  Inc.  1 02 1 1 6-0 

Hygeia  Laboratories,  Inc.  101011-0 

Hygeia  Laboratories,  Inc.  102087-0 

Hygeia  Laboratories,  Inc.  200335-0 

HYGENIX,  INC.  101199-0 

Hygieneering,  Inc.  101997-0 

Hygienetics  Laboratory  Services  101 147-0 

Industrial  Laboratory  1 02 1 1 5-0 

Institute  for  Environmental  Assessment  101249-0 

International  Asbestos  Testing  Laboratory  101 165-0 

Iowa  Environmental  Services,  Inc.  101990-0 

ITEK  Enviro  Services,  Inc.  200032-0 

Jimmie  Ann  Bolton  101735-0 

JLC  Environmental  Consultants,  Inc.  101953-0 

JMS  Environmental  Associates,  Ltd.  102012-0 

KAM  Consultants  102047-0 

Kellco  Services,  Inc.  101331-0 

Kevco  Services,  Inc.  1 0 1 94 1  -0 

Kingston  Environmental  Laboratory  200041-0 

LA  Testing  200232-0 

Labcorp  Analytics  Laboratory  1 0 1 004-0 

Larron  Laboratory  101415-0 

Law  Engineering  and  Environmental  1 0 1 066-0 
Services,  Inc. 

Law  Engineering  and  Environmental  101 152-0 
Services,  Inc. 

Law  Engineering  and  Environmental  101226-0 
Services,  Inc. 

Law  Engineering  and  Environmental  101515-0 
Services,  Inc. 

Law  Engineering  and  Environmental  101515-1 
Services,  Inc. 

Law  Engineering  and  Environmental  101 847-0 
Services,  Inc. 


Hayward 

Rancho  Domingues 

Richmond 

Denver 

Eddystone 

East  Syracuse 

Columbus 

Atlanta 

Tampa 

Reading 

Louisville 

Los  Alamitos 

St.  Petersburg 

Cypress 

Webster 

Union 

Waltham 

Sierra  Madre 

Woburn 

Marietta 

Miami 

Stamford 

Willowbrook 

Boston 

Portsmouth 

Brooklyn  Park 

Mt.  Laurel 

Des  Moines 

South  San  Francisco 

Austin 

New  York 

Westmont 

Long  Island  City 

Hayward 

Butler 

Lee's  Summit 
S.  Pasadena 
Richmond 
Cape  Girardeau 
Birmingham 

Houston 

Charlotte 

Tampa 

Miami  Lakes 

Sterling 


CA 
CA 
VA 
CO 
PA 
NY 
OH 
GA 
FL 
PA 
KY 
CA 
FL 
CA 

TX 

NJ 

MA 

CA 

MA 

GA 

FL 

CT 

IL 

MA 

VA 

MN 

NJ 

IA 

CA 

TX 

NY 

IL 

NY 

CA 

PA 

MO 

CA 

VA 

MO 

AL 

TX 

NC 

FL 

FL 

VA 


NVLAP  1999  DIRECTORY  -  Page  B13 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  B.  LISTING  BY  FIELD  OF  ACCREDITATION  -  continued 


LABORATORY  NAME 


NVLAP 
LAB  CODE 


CITY 


STATE/ 
COUNTRY 


Law  Engineering  and  Environmental  101973-0  Dallas 
Services,  Inc. 

Law  Engineering  and  Environmental  102035-0  Phoenix 
Services,  Inc. 

Legend  Technical  Services,  Inc.  102081-0  St.  Paul 

Lockheed  Martin  Utility  Services,  Inc.  101383-0  Piketon 

Loflin  Environmental  Services  102044-0  Houston 

Los  Angeles  Harbor  Department  Testing  102020-0  Wilmington 
Laboratory 

Los  Angeles  Unified  School  District  101505-0  Los  Angeles 

Louisiana  Department  of  Environmental  102000-0  Baton  Rouge 
Quality  Microanalytical  Lab 

m.a.c.  Paran  Consulting  Services,  Inc.  102108-0  Amelia 

MACS  Lab,  Inc.  101948-0  Santa  Clara 

Marine  Chemist  Service,  Inc.  101425-0  Newport  News 

Materials  Analytical  Services,  Inc.  101235-0  Suwanee 

Maxim  Technologies,  Inc.  101091-0  Dallas 

Maxim  Technologies,  Inc.  101091-1  Houston 

Maxim  Technologies,  Inc.  101292-0  Billings 

McCall  and  Spero  Environmental,  Inc.  101895-0  Louisville 

McKee  Environmental  Health,  Inc.  101135-0  Friendswood 

Metropolitan  Environmental  Testing  Services       200165-0  Waldorf 
dba  METS  Laboratories 

Micro  Air  of  Texas,  Inc.  102008-0  Houston 

Micro  Air,  Inc.  101221-0  Indianapolis 

Micro  Analytical  Laboratories,  Inc.  101151-0  Gainesville 

Micro  Analytical  Laboratories,  Inc.  101872-0  Emeryville 

Micro  Analytical  Laboratories,  Inc.  200054-0  San  Francisco 

Micro  Analytical,  Inc.  101247-0  Milwaukee 

Microbac  Laboratories,  Inc.  101035-0  Erie 

Micron  Environmental  Labs  200294-0  Arcadia 

Microscopic  Analysis,  Inc.  101037-0  St.  Louis 

Midwest  Laboratories,  Inc.  101894-0  Countryside 

Mountain  Laboratories  101890-0  Spokane 

MRS.,  Analytical  Laboratory,  Inc.  1021 13-0  Louisville 

Muranaka  Environmental  Consultants,  Inc.  102085-0  Honolulu 

Mystic  Air  Quality  Consultants,  Inc.  1 0 1 282-0  Groton 

NASA-Lewis  Research  Center  200130-0  Cleveland 

NATEC  International,  Inc.  101155-0  Garden  Grove 

National  Analytical  Laboratories,  Inc.  102080-0  Roseville 

National  Econ  Corporation  102062-0  Tustin 

National  Econ  Corporation  200047-0  Memphis 

National  Environmental  Reference  101593-0  Denver 
Laboratory 

New  York  Testing  Laboratories,  Inc.  101332-0  Bay  Shore 

Niche  Analysis,  Inc.  102057-0  Mount  Vernon 

Northeast  Test  Consultants  101565-0  Westbrook 

Northern  Testing  Laboratories,  Inc.  101463-0  Fairbanks 

Northwest  Envirocon,  Inc.  101869-0  Vancouver 

Nova  Consulting  Group,  Inc.  101545-0  Chaska 

NVL  Laboratories,  Inc.  102063-0  Seattle 

NY  Environmental  &  Analytical  Labs,  Inc.  101967-0  Port  Washington 


TX 

AZ 

MN 
OH 
TX 
CA 

CA 
LA 

OH 
CA 
VA 
GA 
TX 
TX 
MT 
KY 
TX 
MD 

TX 

IN 

FL 

CA 

CA 

WI 

PA 

CA 

MO 

IL 

WA 

KY 

HI 

CT 

OH 

CA 

CA 

CA 

TN 

CO 

NY 
NY 
ME 
AK 
WA 
MN 
WA 
NY 


NVLAP  1999  DIRECTORY  -  Page  B14 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  B.  LISTING  BY  FIELD  OF  ACCREDITATION  -  continued 


LABORATORY  NAME 

NVLAP 
LAB  CODE 

CITY 

STATE/ 
COUNTI 

O'Brien  &  Gere  Laboratories,  Inc. 

1  A  1  1  A  1  A 

1  (J  1 J43-0 

Syracuse 

IN  Y 

Oak  Ridge  National  Laboratory 

200225-0 

Oak  Ridge 

IN 

OCCU- 1  EC,  Inc. 

1  A1"*  AO  C  A 

102025-0 

Kansas  City 

MO 

Occupational  Health  Conservation,  Inc. 

1 AOACA  A 

102050-0 

Jacksonville 

T?T 

r  L 

Oklahoma  Dept.  of  Environmental 

1  AO  1  1  O  A 

1021 12-0 

Oklahoma  City 

OK 

Quality-State  Environmental  Lab 

Omni  Environmental,  Inc. 

l  mAA  i  a 
1 UZUO 1  -u 

Austin 

TV 

1 A 

PA  DEP  Bureau  of  Laboratories 

i  /inn  a 

101323-0 

Harrisburg 

n  a 

PA 

Pace  Analytical 

101203-0 

Indianapolis 

TXT 

IN 

Pacific  Environmental  Services,  Inc. 

i  a  i  i  on  a 

loi iyo-o 

Herndon 

V  A 

Pacific  Rim  Environmental,  Inc. 

101631-0 

Tukwila 

WA 

Patriot  Environmental  Laboratory  Services 

200358-0 

Garden  Grove 

CA 

PBS  Environmental  Building  Consultants, 
r  

1  A  1  A  1  A  A 

i  o  i  y  i  o-o 

rortland 

AD 

UK 

Inc. 

Philip  Analytical  Services 

1  A  1  I  £  1  A 

101262-0 

Reading 

PA 

Philip  Environmental  Services  Corp. 

1  A 1  1  (11  A 

ioi iy/-o 

Columbia 

1 L 

Pinchin  Environmental  Ltd. 

101270-0 

Mississauga  Ontario 

A  XI  AHA 

CANADA 

PMK  Group,  Inc. 

1  A  1  1  A  1  A 

101301-0 

Kenilworth 

XTT 

NJ 

Precision  Micro-Analysis,  Inc. 

101050-0 

Sacramento 

CA 

Precision  Testing  Laboratories,  Inc. 

lAi ccn  a 
1U156U-U 

Moore 

\J  IV 

Prezant  Associates,  Inc. 

1  A1  CO/;  A 

101560-0 

Seattle 

\\J  A 

W  A 

ProScience  Analytical  Services,  Inc. 

0 AAAQ A  A 

Woburn 

fV/I  A 
1V1/Y 

PSI 

1  A  1  O  A  1  A 

101342-0 

Lawrence 

PSI 

1  A  1  1  C  A  A 

101350-0 

Pittsburgh 

D  A 

r  A 

PSI 

1  A  1  -7C  c  A 

101755-0 

New  York 

xrv 
N  Y 

PSI 

1  A  1  C\Hf\  A 

101970-0 

Brea 

CA 

PSI,  Inc. 

1  A  1  A"7A  A 

1010 /O-O 

Farmingdale 

IN  Y 

ri>l,  inc. 

1AAA/11  A 

20004Z-0 

New  Berlin 

WT 

Puget  Sound  Naval  Shipyard 

1  U  1  J  D  J-\) 

Bremerton 

W  A 
VV  rV 

QuanTEM  Laboratories,  LLC 

1  A  1 G<\G  A 

1 U 1  yjy-U 

Oklahoma  City 

VJ1V 

Quest  MicroAnalytics,  Inc. 

TAAO/IQ  A 

riallac 
L/allaS 

TV 

R.  Robinson  Analytical  Services,  Inc. 

1  AOA/1  1  A 

1UZU41-U 

Pensacola 

FT 

Rapid  Environmental  Management,  Inc. 

1  A  1  ClH  A  A 

ioiy  /4-0 

Great  Neck 

IN  Y 

RCM  Laboratories,  Inc. 

1  A  1  O  C  ">  A 

101853-0 

Countryside 

IT 

IL 

Reservoirs  Environmental  Services,  Inc. 

lAion/c  a 

lOloyO-O 

Denver 

Reservoirs  Environmental  Services,  Inc. 

i  a  1  po/;  i 

loieyo-i 

Houston 

TV 

1 A 

RI  Analytical  Laboratories,  Inc. 

1  A  1  A  A  A  A 

1 0 1440-0 

Warwick 

T?T 
KJ 

RJ  Lee  Group,  Inc. 

i a  1 O AC  A 

1 0 1 206-0 

Monroeville 

P  A 
r  A 

RJ  Lee  Group,  Inc. 

i A  1 OAC  O 

1 0 1 206-2 

San  Leandro 

C  A 

L-A 

RJ  Lee  Group,  Inc. 

l A  1 OAC  1 

1 0 1 206-3 

Manassas 

XT' A 
V  A. 

RJ  Lee  Group,  Inc. 

1  A  1  OAS?  < 

1 0 1 206-5 

Houston 

TY 
1  A 

Roy  F.  Weston,  Inc. 

1  A 1  ~)  £  A  A 

101254-0 

Auburn 

A  T 
AL 

S&Mb,  Inc. 

1020/5-0 

cnanotte 

INU 

Safe  Environment  of  America 

i A1A1 l  A 

102021-0 

Kent 

W  A 
W  A 

Schneider  Laboratories,  Inc. 

1  A  1  1  C  A  A 

101 I50-0 

Richmond 

\f  A 
V  A 

Scientific  Laboratories,  Inc. 

1  A  1  A  A  A  A 

ioiyo4-o 

Midlothian 

\/  A 
V  A 

Scientific  Laboratories,  Inc. 

1  A  1  A  A  A  1 

101904-1 

New  York 

IN  Y 

SCILAB  BOSTON,  Inc. 

1  AOA~70  A 

1020  /y-o 

East  Weymouth 

\A  A 

SCILAB  California,  Inc. 

OAA1/I/;  A 

200340-0 

Carson 

r1  a 

SEAS,  Inc 

1  A  1  t  C<  A 

101 165-0 

Blacksburg 

V  A 

V  A 

Severn  Trent  Laboratories  (MA) 

101005-0 

N.  Billerica 

MA 

Solar  Environmental  Services,  Inc. 

102006-0 

Anchorage 

AK 

NVLAP  1999  DIRECTORY  -  Page  B15 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  B.  LISTING  BY  FIELD  OF  ACCREDITATION  -  continued 


LABORATORY  NAME 

TVVT  A  P 

LAB  CODE 

CITY 

CT  A  'IT?  / 

COUNTRY 

South  Carolina  Department  of  Health  & 

101572-0 

Columbia 

sc 

Environmental  Control 

South  Coast  Air  Quality  Management  District 

101567-0 

Diamond  Bar 

CA 

STAT  Analysis  Corporation 

101202-0 

Chicago 

IL 

State  of  Connecticut 

101237-0 

Hartford 

CT 

Steve  Moody  Micro  Services,  Inc. 

102056-0 

Carrollton 

TX 

Sun  City  Analytical,  Inc. 

101870-0 

El  Paso 

TX 

Taylor  Environmental  Group,  Inc. 

102101-0 

Floral  Park 

NY 

TC  Analytics,  Inc. 

101672-0 

Norfolk 

VA 

TEC-AN,  Inc. 

200325-0 

Oklahoma  City 

OK 

TEM,  Incorporated 

101 130-0 

Glen  Ellyn 

IL 

Testing  Mechanics  Corp. 

102001-0 

Seaford 

NY 

Testwell  Laboratories,  Inc./Testwell 

200083-0 

Ossining 

NY 

Industries,  Inc. 

The  Scott  Lawson  Group,  Ltd. 

101228-0 

Concord 

NH 

TolTest,  Inc. 

101594-0 

Toledo 

OH 

TRC  Environmental  Corporation 

101424-0 

Windsor 

CT 

Tremco,  Inc.  -  Roofing  Division,  An  RPM 

101 188-0 

Beachwood 

OH 

Company 

Triad  Environmental  Consulting,  Inc. 

102073-0 

Huntington 

WV 

U.S.  Army  Center  for  Health  Promotion  and 

200044-0 

Aberdeen  Proving  Ground 

MD 

Preventive  Medicine 

U.S.  EPA  -  National  Enforcement 

101703-0 

Denver 

CO 

Investigations  Center 

United  Analytical  Services,  Inc. 

101732-0 

Hillside 

IL 

University  (State)  Hygienic  Laboratory 

101288-0 

Iowa  City 

I A 

University  of  Alabama  Asbestos  Laboratory 

102005-0 

Tuscaloosa 

AL 

Volz  Environmental  Services,  Inc. 

101269-0 

Pittsburgh 

PA 

Waste  Management  Federal  Services  of 

101058-0 

Richland 

WA 

Hanford,  Inc. 

Water,  Earth  Solutions  &  Technologies,  Inc. 

102043-0 

Dallas 

TX 

Wausau  Insurance  Companies 

101079-0 

Wausau 

WI 

Western  Analytical  Laboratory 

200037-0 

Burbank 

CA 

White  Environmental  Consultants  Inc. 

200124-0 

Anchorage 

AK 

White  Environmental  Consultants,  Inc. 

200350-0 

Honolulu 

HI 

Wisconsin  Occupational  Health  Laboratory 

101109-0 

Madison 

WI 

WKP  Laboratories,  Inc. 

101950-0 

Ossining 

NY 

Wonder  Makers  Environmental,  Inc. 

102065-0 

Kalamazoo 

MI 

Asbestos  Fiber  Analysis  (TEM  Test  Method) 

Aires  Consulting  Group,  Inc. 

101014-0 

Batavia 

IL 

AMA  Analytical  Services,  Inc. 

101143-0 

Lanham 

MD 

Analytica  Solutions,  Inc. 

101086-0 

Broomfield 

CO 

ASBESTECH 

101442-0 

Carmichael 

CA 

Asbestos  TEM  Laboratories,  Inc. 

101891-0 

Berkeley 

CA 

ATC  Associates,  Inc. 

101187-0 

New  York 

NY 

Batta  Laboratories,  Inc. 

101032-0 

Newark 

DE 

Braun  Intertec  Corporation 

101234-0 

Minneapolis 

MN 

Carnow,  Conibear  &  Associates  Ltd. 

101039-0 

Chicago 

IL 

Chopra-Lee,  Inc. 

200095-0 

Grand  Island 

NY 

Clayton  Laboratory  Services 

101125-0 

Kennesaw 

GA 

Crisp  Analytical  Laboratory 

200349-0 

Carrollton 

TX 

DataChem  Laboratories 

101917-0 

Cincinnati 

OH 

NVLAP  1999  DIRECTORY  -  Page  B16 

(See  'How  To  Use  This  Directory'  on  page  7.) 

INDEX  B.  LISTING  BY  FIELD  OF  ACCREDITATION  -  continued 


LABOKAIORY  JNAMK 

NVLAP 
LAB  CODE 

CITY 

STATE/ 
COUN I RY 

E.  M.  Analytical,  Inc. 

101902-0 

Dania 

FL 

Eastern  Analytical  Services,  Inc. 

101646-0 

Elmsford 

NY 

EMS  Laboratories,  Inc. 

101218-0 

Pasadena 

CA 

EMSL  Analytical  Mobile  Laboratory 

200344-0 

Chicago 

IL 

EMSL  Analytical,  Inc. 

101048-0 

Westmont 

NJ 

EMSL  Analytical,  Inc. 

101048-1 

Atlanta 

GA 

EMSL  Analytical,  Inc. 

101048-2 

Piscataway 

NJ 

EMSL  Analytical,  Inc. 

101048-3 

San  Mateo 

CA 

EMSL  Analytical,  Inc. 

101048-4 

Ann  Arbor 

MI 

EMSL  Analytical,  Inc. 

101048-9 

New  York 

NY 

EMSL  Analytical,  Inc. 

101048-10 

Carle  Place 

NY 

EMSL  Analytical,  Inc. 

101277-0 

Fairfax 

VA 

EMSL  Analytical,  Inc. 

102104-0 

Greensboro 

NC 

EMSL  Analytical,  Inc. 

102106-0 

Houston 

TX 

EMSL  Analytical,  Inc. 

200019-0 

Seattle 

WA 

EMSL  Analytical,  Inc. 

200034-0 

Dallas 

TX 

EMSL  Analytical,  Inc. 

200056-0 

Williamsville 

NY 

EMSL  Analytical,  Inc. 

200188-0 

Indianapolis 

IN 

EMSL  Analytical,  Inc. 

200204-0 

N.  Miami  Beach 

FL 

EMSL  Analytical,  Inc. 

200293-0 

Beltsville 

MD 

EMSL  Analytical,  Inc. 

200310-0 

Carlstadt 

NJ 

EMSL  Analytical,  Inc. 

200333-0 

Elmsford 

NY 

EMSL  Analytical,  Inc. 

200375-0 

Baton  Rouge 

LA 

Environmental  Testing  Laboratories,  Inc. 

101937-0 

Farmingdale 

NY 

Fiberquant,  Inc. 

101031-0 

Phoenix 

AZ 

Forensic  Analytical  Specialties,  Inc. 

101459-0 

Hayward 

CA 

Gelles  Laboratories,  Inc. 

101 170-0 

Columbus 

OH 

Geo-Analytical  Services,  Inc. 

102082-0 

Atlanta 

GA 

Hygeia  Laboratories  Inc. 

1021 16-0 

Sierra  Madre 

CA 

Hygeia  Laboratories,  Inc. 

101011-0 

Woburn 

MA 

Hygeia  Laboratories,  Inc. 

200335-0 

Miami 

FL 

Hygienetics  Laboratory  Services 

101147-0 

Boston 

MA 

International  Asbestos  Testing  Laboratory 

101165-0 

Mt.  Laurel 

NJ 

JMS  Environmental  Associates,  Ltd. 

102012-0 

Westmont 

IL 

KAM  Consultants 

102047-0 

Long  Island  City 

NY 

LA  Testing 

200232-0 

S.  Pasadena 

CA 

Lab/Cor,  Inc. 

101920-0 

Seattle 

WA 

Los  Angeles  Unified  School  District 

101505-0 

Los  Angeles 

CA 

MACS  Lab,  Inc. 

101948-0 

Santa  Clara 

CA 

Materials  Analytical  Services,  Inc. 

101235-0 

Suwanee 

GA 

Maxim  Technologies,  Inc. 

101091-0 

Dallas 

TX 

McCall  and  Spero  Environmental,  Inc. 

101895-0 

Louisville 

KY 

Micro  Analytical  Laboratories,  Inc. 

101151-0 

Gainesville 

FL 

Micro  Analytical  Laboratories,  Inc. 

101872-0 

Emeryville 

CA 

Midwest  Laboratories,  Inc. 

101894-0 

Countryside 

IL 

New  York  Testing  Laboratories,  Inc. 

101332-0 

Bay  Shore 

NY 

O'Brien  &  Gere  Laboratories,  Inc. 

101343-0 

Syracuse 

NY 

Pace  Analytical 

101265-0 

Indianapolis 

IN 

Philip  Analytical  Services 

101262-0 

Reading 

PA 

ProScience  Analytical  Services,  Inc. 

200090-0 

Woburn 

MA 

PSI 

101350-0 

Pittsburgh 

PA 

QuanTEM  Laboratories,  LLC 

101959-0 

Oklahoma  City 

OK 

NVLAP  1999  DIRECTORY  -  Page  B17 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  B.  LISTING  BY  FIELD  OF  ACCREDITATION  -  continued 


LABORATORY  NAME 

NVLAP 
LAB  CODE 

CITY 

STATE/ 
COUNTRY 

Reservoirs  Environmental  Services,  Inc. 

101896-0 

Denver 

CO 

Reservoirs  Environmental  Services,  Inc. 

101896-1 

Houston 

TX 

RJ  Lee  Group,  Inc. 

101208-0 

Monroeville 

PA 

RJ  Lee  Group,  Inc. 

101208-2 

San  Leandro 

CA 

RJ  Lee  Group,  Inc. 

101208-3 

Manassas 

VA 

RJ  Lee  Group,  Inc. 

101208-5 

Houston 

TX 

Scientific  Laboratories,  Inc. 

101904-0 

Midlothian 

VA 

Scientific  Laboratories,  Inc. 

101904-1 

New  York 

NY 

SCILAB  BOSTON,  Inc. 

102079-0 

East  Weymouth 

MA 

SCILAB  California,  Inc. 

200346-0 

Carson 

CA 

Severn  Trent  Laboratories  (MA) 

101005-0 

N.  Billerica 

MA 

STAT  Analysis  Corporation 

101202-0 

Chicago 

IL 

Steve  Moody  Micro  Services,  Inc. 

102056-0 

Carrollton 

TX 

TEM,  Incorporated 

101130-0 

Glen  Ellyn 

IL 

Testvvell  Laboratories,  Inc./Testwell 

200083-0 

Ossining 

NY 

Industries,  Inc. 

University  (State)  Hygienic  Laboratory 

101288-0 

Iowa  City 

IA 

Fasteners  &  Metals 

3V  Fasteners  Co.  Inc.  Testing  Laboratory 

200264-0 

Corona 

CA 

Acominas  -  Analysis  and  Testing  Laboratory 

200185-0 

Ouro  Branco  MG 

BRAZIL 

Aerospace  NYLOK  -  a  subsidiary  of  the 

200271-0 

Hawthorne 

NJ 

NYLOK  Fastener  Corporation 

Aerospace  Rivet  Manufacturers  Corp. 

200266-0 

Santa  Fe  Springs 

CA 

Alloy  &  Stainless  Testing 

200353-0 

Virginia  Beach 

VA 

Aoyama  Fastener  Laboratory 

200213-0 

Niwa-gun,  Aichi  Prefecture 

JAPAN 

Arden  Fasteners 

200187-0 

Addison 

IL 

Asakawa  Screw  Co.,  Ltd. 

200197-0 

Yokohama 

JAPAN 

Asakawa  Screw  Co.,  Ltd.  Kawawa  Factory 

200257-0 

Yokohama 

JAPAN 

BarTech  Inc.  -  Chemical  Laboratory 

200148-0 

Johnstown 

PA 

BCAG  Fastener  Quality  Test  Lab  Everett  Site 

200292-0 

Seattle 

WA 

Belgo-Mineira  Chemical  Laboratory 

200196-0 

35.930-900  Joao  Monlevade 

BRAZIL 

Binder  Metal  Products,  Inc. 

200321-0 

Gardena 

CA 

Bodycote  Industrial  Testing,  Inc. 

101072-0 

St.  Louis 

MO 

California  Screw  Products 

200183-0 

Paramount 

CA 

Casey  Products,  Inc. 

200278-0 

Lisle 

IL 

CBS  Fasteners,  Inc. 

200253-0 

Anaheim 

CA 

Dexter  Fastener  Technologies,  Inc. 

200144-0 

Dexter 

MI 

Durkee  Testing  Laboratories,  Inc. 

200178-0 

Paramount 

CA 

Fabristeel  Products  Inc. 

200329-0 

Taylor 

Ml 

Fastener  Innovation  Technology,  Inc. 

200179-0 

Gardena 

CA 

Federal  Manufacturing  Corp. 

200279-0 

Chatsworth 

CA 

Fong  Prean  Industrial  Co.,  Ltd. 

200288-0 

Kaohsiung  Hsien 

TAIWAN 

Fuji  Buhin  Kogyo  Kabushiki  Kaisha 

200203-0 

Ohta  Gunma 

JAPAN 

Fuji  Component  Parts  USA,  Inc. 

200180-0 

Indianapolis 

IN 

Fuserashi  Gunma 

200173-0 

Gunma-Ken 

JAPAN 

Fwu  Kuang  Enterprises  Co.,  Ltd. 

200286-0 

Tainan  Hsien 

TAIWAN 

Hadd-Co  Inspection  Lab 

200326-0 

Torrance 

CA 

Incotec  Laboratory 

200339-0 

Mojave 

CA 

Indiana  Automotive  Fasteners,  Inc. 

200150-0 

Greenfield 

IN 

Ingersoll  Fasteners 

200208-0 

Ingersoll  Ontario 

CANADA 

NVLAP  1999  DIRECTORY  -  Page  B18 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  B.  LISTING  BY  FIELD  OF  ACCREDITATION  -  continued 


LABORATORY  NAME 


NVLAP 
LAB  CODE 


CITY 


STATE/ 
COUNTRY 


Ivaco  Roiling  Mills,  Chemistry  Laboratory  200143-0 

J.W.  Mfg.  DBA  Van  Petty  Mfg.  200225-0 

Kobelco  Research  Institute,  Inc.  Stock  200 1 69-0 
Company 

Korea  Testing  &  Research  Inst,  for  Chemical  200177-0 
Industry-Inchon  Off. 

Kyowa  Kogyosyo  Co.,  Ltd.  Test  Laboratory  200274-0 

Leland-Powell  Fasteners,  Inc.  Fastener  200171-0 
Testing  Laboratory 

M&M  Manufacturing  Corportation  200356-0 

MAC  Fasteners,  Inc.  200141-0 

MacLean  Fasteners  -  QC  Laboratory  200153-0 

Meidoh  Laboratory  200239-0 

Metallic  Material  Laboratory  in  Toyota  200223-0 
Motor  Co. 

Minebea  Co.,  Ltd.  Fujisawa  Manufacturing  200229-0 
Unit 

Modern  Plating  Corporation  200320-0 

MQS  Inspection,  Inc.  Magnetic  Particle  &  2003 14-0 
Liquid  Penetrant  Exam. 

Multifastener  Laboratory  200267-0 

Northwestern  Steel  and  Wire  Company  200224-0 

NOVA  Machine  Products  200202-0 

NSS  Technologies  200 1 84-0 

NYLOK  Fastener  Corporation  200272-0 

NYLOK  Fastener  Corporation  200273-0 

NYLOK  Fastener  Corporation  -  Chicago  200275-0 
Testing  Laboratory 

O  &  K  Company  Limited,  Osaka  Test  Center  200166-0 

Okai  Iron  Works  Co,  Ltd.  200299-0 

Okawa  Laboratory  200296-0 

Owari  Precise  Products  Co,  Ltd.  200227-0 

PB  Fasteners  200139-0 

Portland  Bolt  and  Manufacturing  Company,  200168-0 
Inc.  Testing  Laboratory 

Pratt  &  Whitney  Materials  Control  200336-0 
Laboratory 

Prospect  Testing  Labs,  Inc.  200328-0 

Prottsa,  S. A.  de  C. V.  20026 1  -0 

Republic  Fastener  Manufacturing  200 1 95-0 

Rightway  Fasteners,  Inc.  200210-0 

Robbins  Manufacturing  Co,  Inc.  200161-0 

Rockford  Bolt  &  Steel  Co.  200255-0 

Rocknel  Fastener  Inc.  200307-0 

San  Shing  Hardware  Works  Co,  Ltd.  Test  200158-0 
Laboratory 

Sannohashi  Corporation  200205-0 

Saturn  Fasteners,  Inc.  200327-0 

SNB  Laboratory  200308-0 

SPS  Technologies  Aerospace  Product  200298-0 
Division 

SPS  Technologies;  Aerospace  Fastener  Group  200164-0 


L'Orignal  Ontario 
Newbury  Park 
Kobe 

Inchon 

Komatsu  City,  Ishikawa 
Martin 

Chino 
Ottawa 
Mundelein 
Toyota,  Aichi 
Toyota  city  Aichi 

Fujisawa,  Kanagawa 

Freeport 

Santa  Fe  Springs 

Taylor 
Sterling 

Middleburg  Heights 

Plymouth 

Anaheim 

Macomb 

Lincolnwood 

Osaka-Shi 

Izumisano  Osaka 

Naka-gun,  Ibaraki-ken 

Nagoya 

Gardena 

Portland 

East  Hartford 

Des  Plaines 
Mexico  City 
Newbury  Park 
Columbus 
Fall  River 
Rockford 
Rockford 
Tainan 

Yashioshi,  Saitama-ken 
Burbank 
Cumberland 
Santa  Ana 

Jenkintown 


CANADA 
CA 

JAPAN 

KOREA 

JAPAN 
TN 

CA 
KS 
IL 

JAPAN 
JAPAN 

JAPAN 

IL 
CA 

MI 

IL 

OH 

MI 

CA 

MI 

IL 

JAPAN 

JAPAN 

JAPAN 

JAPAN 

CA 

OR 

CT 

IL 

MEXICO 

CA 

IN 

MA 

IL 

IL 

TAIWAN 

JAPAN 
CA 
RI 
CA 

PA 


NVLAP  1999  DniECTORY  -  Page  B19 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  B.  LISTING  BY  FIELD  OF  ACCREDITATION  -  continued 


LABORATORY  NAME 

1\  V  JLAr 

LAB  CODE 

CITY 

CT  a  i  t;  / 

alAlL/ 
COUNTRY 

Sunjiura  Seisakusho  Co.,  Ltd. 

200226-0 

Nishio  Aichi 

JAPAN 

Sumitomo  Metal  Technology,  Inc.  Kokura 

200215-0 

Kitakyushu 

JAPAN 

P)i  vision 

Sundram  Fasteners  Limited  (Inhouse  test 

200212-0 

Chennai  (Madras),  Tamil,  Nadh 

INDIA 

lahorat/orv^ 

Sundram  Fasteners  Limited  Chemical  Testing 

200256-0 

Andhra  Pradesh 

INDIA 

Laboratory 

Super  Cheng  Industrial  Testing  Laboratory 

200280-0 

FCaoh^iunfj  Kanp^han 

1\  UU  llOIVillel,,    1  \  ti  1  1  L  ■  1  1  1  U  1  1 

TAIWAN 

The  Monadnock  Company 

200268-0 

—  W  —  W  U  V/ 

Citv  of  InHiKtrv 

V_   1  I  ¥    \J  I    11  lUUiJll  Y 

CA 

The  Perryman  Company 

200128-0 

Houston 

PA 

Topura  Co.,  Ltd. 

200181-0 

Hadano  Kanapawa 

i  1  UUUI  IV/    1  VU1  ICt VV  CI 

JAPAN 

Topura  Co.,  Ltd.  Osaka 

200242-0 

ICatano  O^aka 

1  N.UU1I  IU,  V_/OClIVU 

JAPAN 

Tonura  Co    I  td  Tokat 

200243-0 

O^a^apiin  Slhi7noka 

V_/  t,UOUt,UI  I,U1  1  1  / .  U  U  1\  U 

JAPAN 

TWlSl  Fastpncr  Inc 

1     Till     1     UOlV.1          1  ^     1  1  1  V.  . 

200194-0 

Rowlinf  ("trppn 

LJ  KJ  V  V  1111  ^  V  J  1  H.II 

KY 

I  Initprl  ^stppl  and  Fa,stpnpr<s  fnc 

V     J  M  I  V-  Vl    kj  IV.  V-  1    ill  1  Vl    1    UO.llltl  3    1  1  1  v  , 

?00341 -0 

v/  Vy  .J  "  1  KJ 

Itasca 

IL 

Vermont  Fasfpnprs  Manufacturing 

V  VI  1  1  >  V  M  1  I    1    UJlvllLl  J    IV!cillLll<JVlUI  1  1  1  ii, 

200254-0 

Swant  on 

VT 

x/ulcan  Rivpt  an<t  Rolt  Conioraf  ion 

V  U  1  <•  itll    1  x  1  V  V,  I  cl  1  1  Vl   LJ  KJ  1  I   V    \J  1  UUI  ci  I  I  V  i  1 

200277-0 

—  KJ  v/*-  /  /  KJ 

R  i  rm  i  n  o  h  n  m 

AL 

Walker  Rolf  Manufacturing  Co 

200126-0 

FToi  i*sfon 

1  IUU jLUI  i 

TX 

Wilson-Garner  Company 

200136-0 

Harrison  Township 

MI 

Wolverine  Plating  Corp. 

200230-0 

Roseville 

MI 

Yamaha  Motor  Metal  Testing  Laboratory 

2002  / o-O 

Iwata  Shizuoka 

T  A  n  A  XT 

JAPAN 

Fasteners  and  Metals 

PRODUCT  TESTING  GROUP 

Acoustical  Testing  Services 

Acoustic  SvsIpiits  Acoustical  Rp^parch 

r\  v,  v<  vl ol  1  C  O  Volvlllo  i\  ^UUoUCul  IN.  V.  o  V-  CI  1  V.  1 1 

1 00286-0 

I  V  /  KJ  _  O  KJ  KJ 

A  i  i^tin 

TX 

F'IPl  1  i  tv 
i  civ,  1 1 1 1  y 

Acaro  Comnnnv  F-A-RCAT  Acoustical 

iivtiiv'  v^wiiiL/Liiiy,  i  -  rv  i  x  v  r\.  i_<  .  \  v.vjuoiiv,cii 

1 00374-0 

[nHiananol  k 

IN 

T  ahovatorv 

Architectural  Testing  Inc. 

200361-0 

York 

PA 

Armstrong  Acoustic  Labs,  Armstrong  World 

100228-0 

Lancaster 

PA 

Ind.  Inc.  Innov.  Center 

Celotex  Technical  Center 

100417-0 

St.  Petersburg 

FL 

DpII  Rppnlatorv  Tpst  I  ahoratonps 

i      VII     1  \  V  ._  1  1  1  1. 1  1  V  '  1    ■      1  V.  O  I    1  i-l  UUI  ULUI  1  V-  O 

200052-0 

Round  Rock' 

TX 

M 1 1  fpnr  1  annratnrv 

1  1  Ll  i  v  KJ  1    l^ClUKJi  U.IKJI  y 

1 OO'MQ-O 

i           y  k) 

I TriPQVl  1 1  P 

J  u  ii  l  o  \  mi 

WI 

[ R KA  1-4 1 1 Hcon  \7i  1 1  p  v  A  rniKtiPC  f  ihnnfnrv 

1  L>  1 VI   1  1  UvioVJ  1 1    V  Ul  IC  y   ntUU&l  Ivo  LtlUUl  ulUl  y 

1 003^3-0 

Pr»i  iQnl'PPncip 

r  (JUKI  IKLCJJjIC 

NY 

f n H 1 1 ctri •  1 1  ArniicfiPv  i  nmnnTi \/  Inr 

■  1  1 1  H.  Ml  Icli  nlUUMIlo  V_  \J  1  1  1 U  cl  1  1  V  , 

1 00404-0 

Bronx 

NY 

A  r*rn-  A  frti  istipc  I  anArsitrtrv 

f\vl  U   r\  LUUMIvo  L^CIUKJ  l  <-ll\J\  y 

lohns  ManviUp  Tpchnical  ("'pntpr 

J  U  1 1 1  1  o  I V  1  til  I  V  1 1  1  V.    1  v.  L  1  1  1  1  1  v.  lI  1   V_  v  1  1  I  v  1 

1 00425-0 

1  KJKJ'-r     _}  KJ 

I  ittlpton 

CO 

Mnxini  Tpchnolopips  Inc 

'.■Ml      1  V»  V  1  lllV/lV/t,IV.O,     1  I  1  V 

200046-0 

j—\jyj\j  i  kj  kj 

St.  Paul 

MN 

Michael  &  Associates 

100427-0 

Stafp  Col  1  ppp 

PA 

NCiC  Testing  Slprvicps  National  dvnsiim 

i  i  vj  \_    i  v     \  i  i  i  ._   uvi  v  i  v  v  ' .   i  ittiiv/iicii  vj  y  uoui  1 1 

200291-0 

Buffalo 

LJ  Lll  lulv 

NY 

Research  Center 

Orfield  Laboratories,  Inc. 

200248-0 

Minneapolis 

MN 

Owens  Corning  Testing  Systems  -  Product 

100109-0 

Granville 

OH 

Tpcti  n  o  I  ^Knntf\rv 

Ricoh  Pnmnflnv  T  TO  Ohmori  Acoustics  Tpst 

Site 

700345-0 

iLKJKJ^'-r^}  \J 

Tokyo 

JAPAN 

Riverbank  Acoustical  Laboratories 

100227-0 

Geneva 

IL 

USG  Research-Systems  Evaluation 

2UU 1 3Z-U 

Libertyville 

Tr 
IL 

Laboratory 

Vibro-Acoustics  Laboratory 

100424-0 

Scarborough  Ontario 

CANADA 

NVLAP  1999  DIRECTORY  -  Page  B20  (See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  B.  LISTING  BY  FIELD  OF  ACCREDITATION  -  continued 


LABORATORY  NAME 


NVLAP 
LAB  CODE 


CITY 


STATE/ 
COUNTRY 


Western  Electro- Acoustic  Lab.,  Inc. 

Carpet  and  Carpet  Cushion 

American  Carpet  Laboratories,  Inc. 
Beaulieu  of  America  -  Carpet  Testing  Lab 
Bentley  Testing  Laboratory 
Commercial  Testing  Company 
Hollytex  Carpet  Mills,  Inc. 
Independent  Textile  Testing  Service,  Inc. 
Mohawk  Industries,  Inc.-  Lyerly  Plant 
Professional  Testing  Laboratory,  Inc. 
Queen  Carpet  Test  Laboratory 
Shaw  Industries,  Inc.,  Central  Laboratory 
Operations 

TSi,  Testing  Services,  Inc. 
Vartest  Laboratories,  Inc. 
World  Carpets,  Inc. 

Commercial  Products  Testing 

Canadian  Standards  Association 
D/L  Laboratories 
Dodge-Regupol,  Inc.  Laboratory 
MacMillan  Bloedel  Packaging,  Inc., 
Combined  Board  Test  Lab 
NAHB  Research  Center,  Inc. 
SGS  U.S.  Testing  Company,  Inc. 
Willamette  Industries,  Inc.  West  Coast 
Development  Lab 

Construction  Materials  Testing 

American  Testing  Laboratories,  Inc. 

ASC  geoscience,  inc. 

City  of  San  Jose,  Materials  Testing 

Laboratory 

Eastern  Materials  Testing  Lab  a  division  of 

Jaworski  Geotech 

Fairfield  Testing  Laboratory,  Inc. 

Fairway  Testing  Company,  Inc. 

Independent  Materials  Testing  Laboratories, 

Inc. 

Inland  Foundation  Engineering,  Inc. 
Materials  Testing,  Inc. 
PSI,  Inc. 

Special  Testing  Laboratories,  Inc. 

STS  Consultants,  Ltd. 

Test-Con  Incorporated 

Testwell  Laboratories,  Inc./Testwell 

Industries,  Inc. 

Tri-State  Materials  Testing  Lab,  Inc. 
W.R.  Grace  &  Co. 


100256-0 

100139-0 
100190-0 
100288-0 
100120-0 
100247-0 
100166-0 
100156-0 
100297-0 
100429-0 
100193-0 

100108-0 
200027-0 
100197-0 


100322-0 
100252-0 
200030-0 
100259-0 

100104-0 
100416-0 
200045-0 


100146-0 
200316-0 
100325-0 

100315-  0 

100317-0 
100340-0 

100316-  0 

100406-0 
100320-0 
100319-0 
100308-0 
100191-0 
200018-0 
200083-0 

200010-0 
200258-0 


Santa  Monica 

Ringgold 
Dalton 

City  of  Industry 

Dalton 

Anadarko 

Dalton 

Lyerly 

Dalton 

Dalton 

Dalton 

Dalton 
New  York 
Dalton 


Etobicoke  Ontario 
New  York 
Lancaster 
Pine  Hill 

Upper  Marlboro 
Tulsa 

Wilsonville 


Lancaster 
Lakeland 
San  Jose 

New  Britain 

Stamford 
Stony  Point 
Plainville 

San  Jacinto 
Milford 
North  Haven 
Bethel 

Vernon  Hills 

Danbury 

Ossining 

Newington 
Cambridge 


CA 

GA 
GA 
CA 
GA 
OK 
GA 
GA 
GA 
GA 
GA 

GA 
NY 
GA 


CANADA 
NY 
PA 
AL 

MD 
OK 
OR 


PA 
FL 

CA 

CT 

CT 
NY 
CT 

CA 

CT 

CT 

CT 

IL 

CT 

NY 

CT 
MA 


NVLAP  1999  DIRECTORY  -  Page  B21 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  B.  LISTING  BY  FIELD  OF  ACCREDITATION  -  continued 


LABORATORY  NAME 


NVLAP 
LAB  CODE 


CITY 


STATE/ 
COUNTRY 


Efficiency  of  Electric  Motors 

Advanced  Energy,  Industrial  Energy 
Laboratory 

GE  Ovvensboro  Test  Laboratory 
MagneTek  (Lexington)  Engineering 
Laboratory 

Marathon  Electric  -  Wausau  Engineering  Lab. 
Oak  Ridge  National  Laboratory  Electric 
Machinery  Center 
Small  IAC  Test  Laboratory 
Toshiba/Houston  Test  Laboratory 

Energy  Efficient  Lighting  Products 

Cooper  Lighting  -  Metalux  Research 
Laboratories 

Daybrite  Lighting  (Genlyte  Thomas  Group) 

Photometric  Laboratory 

Duro-Test  Corporation 

GE  Lighting-  Engineering  Support  -  NA 

Hubbell  Lighting  Photometric  Laboratory 

Intertek  Testing  Services  NA  Inc. 

Lithonia  Testing  Laboratories 

Osram  Sylvania  Inc.,  Test  &  Measurements 

Laboratory 

Philips  Lighting  Corporate  Calibration  & 
Standards  Laboratory 
Thomas  Lighting  Accent  Division 
Photometric  Laboratory 

Thermal  Insulation  Materials 

Celotex  Technical  Center 

Dow  Chemical  N.  America  Foam  Products 

Research,  Prod.  Perf.  Lab. 

Flexible  Products  Company 

Geoscience  Ltd. 

Holometrix  -  Micromet 

Intertek  Testing  Services  NA  Inc. 

Intertek  Testing  Services  NA  Inc. 

Johns  Manville  Technical  Center 

Knauf  Fiber  Glass  Research  Laboratory 

Levecque  Technical  Center 

Maxim  Technologies,  Inc. 

NAHB  Research  Center,  Inc. 

Owens  Corning  Testing  Systems  -  Product 

Testing  Laboratory 

R&D  Services,  Inc. 

Resources,  Applications,  Designs  &  Control, 
Inc.  (RADCO) 

SGS  U.S.  Testing  Company,  Inc. 

St.  of  California,  Bur.  of  Home  Furnishings 

&  Thermal  Insulation 

Underwriters  Laboratories  Inc. 


200081-0 

200305-0 
200053-0 

200134-0 
200244-0 

200287-0 
200088-0 

200050-0 
200016-0 

200283-0 

100398-  0 
200020-0 

100402-  0 
200007-0 

100403-  0 

100399-  0 
200155-0 


100417-0 

100103-  0 

100210-0 
100142-0 
100113-0 
100402-0 
200031-0 
100425-0 
100248-0 
100101-0 
200046-0 

100104-  0 
100109-0 

200265-0 
100261-0 

100416-0 
100251-0 

100414-0 


Raleigh 

Owensboro 
Lexington 

Wausau 
Oak  Ridge 

Peterborough 
Houston 

Americus 

Tupelo 

Clifton 

Cleveland 

Christiansbure 

Cortland 

Conyers 

Beverly 

Fairmont 

Los  Angeles 


St.  Petersburg 
Midland 

Joliet 
San  Diego 
Bedford 
Cortland 
Middleton 
Littleton 
Shelbyville 
Blue  Bell 
St.  Paul 

Upper  Marlboro 
Granville 

Cookeville 
Long  Beach 

Tulsa 

North  Highlands 
Northbrook 


NC 

KY 
TN 

WI 

TN 

CANADA 
TX 

GA 

MS 

NJ 
OH 

VA 
NY 
GA 
MA 

WV 

CA 


FL 
Ml 

IL 

CA 

MA 

NY 

Wl 

CO 

IN 

PA 

MN 

MD 

OH 

TN 
CA 

OK 
CA 

IL 


NVLAP  1999  DIRECTORY  -  Page  B22 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  B.  LISTING  BY  FIELD  OF  ACCREDITATION  -  continued 


LABORATORY  NAME 


NVLAP 

LAB  CODE  CITY 


STATE/ 
COUNTRY 


Wood  Based  Products 

APA  -  The  Engineered  Wood  Association  1 00423-0  Tacoma 
Research  Center 

Composite  Panel  Association  (CPA)  100418-0  Gaithersburg 

PFS  Corporation  100421-0  Madison 

Professional  Service  Industries,  Inc.,  100430-0  Eugene 
Pittsburgh  Test.  Lab.  Div. 

Timberco,  Inc.- dba  TECO  100420-0  Eugene 


WA 

MD 

WI 

OR 

OR 


NVLAP  1999  DIRECTORY  -  Page  B23 


(See  'How  To  Use  This  Directory'  on  page  7.) 


♦ 


• 


• 


INDEX  C.  LISTING  BY  STATE/COUNTRY 
LABORATORY  NAME 


NVL  AT- 
LAS CODE  CITY 


STATE/ 
COUNTRY 


FIELD 


AK 

Northern  Testing  Laboratories,  Inc. 
Solar  Environmental  Services,  Inc. 
White  Environmental  Consultants  Inc. 

AL 


101463-0 
102006-0 
200124-0 


101066-0 


Law  Engineering  and  Environmental 
Services,  Inc. 

MacMillan  Bloedel  Packaging,  Inc.,  1 00259-0 
Combined  Board  Test  Lab 

Roy  F.  Weston,  Inc.  101 254-0 

U.S.  Army  Primary  Standards  Laboratory  105004-0 

U.S.  Army  Radiation  Standards  &  Dosimetry  100539-0 
Laboratory 

University  of  Alabama  Asbestos  Laboratory  102005-0 

Vulcan  Rivet  and  Bolt  Corporation  200277-0 

AR 

Environmental  Enterprise  Group(EEG),  Inc.  101587-0 

AZ 

A.E.S.L.  200303-0 

Arizona  Public  Service  Co.,  Palo  Verde  100536-0 
Nuclear  Generating  Station 

Asbestos  Analytical  101771-0 

Continental  Envirotech,  Inc.  200080-0 
Environmental  Management  Consultants,  Inc.  101926-0 

Fiberquant,  Inc.  101031-0 

Fiberquant,  Inc.  101031-0 

Law  Engineering  and  Environmental  102035-0 
Services,  Inc. 

Motorola  SSTG  EMC/TEMPEST  Laboratory  100405-0 
Motorola  SSTG  EMC/TEMPEST  Laboratory  100405-0 

CA 

3V  Fasteners  Co.  Inc.  Testing  Laboratory  200264-0 

Aerospace  Rivet  Manufacturers  Corp.  200266-0 

Analytical  Labs  San  Francisco,  Inc.  101909-0 

Apple  Computer,  Inc.,  EMC  Compliance  200071-0 
Laboratory 

ASBESTECH  101442-0 

ASBESTECH  101442-0 

Asbestos  TEM  Laboratories,  Inc.  101891-0 

Asbestos  TEM  Laboratories,  Inc.  101891-0 

AST  Research,  Inc.  EMC  Lab.  200135-0 

Bay  Area  Air  Quality  Management  District  1 02090-0 

Bay  Area  Compliance  Laboratory,  Corp.  200167-0 

Bentley  Testing  Laboratory  1 002  88-0 

Binder  Metal  Products,  Inc.  20032 1  -0 

California  Screw  Products  200 1 83-0 

CAMCOLab  101803-0 

CBS  Fasteners,  Inc.  200253-0 


Fairbanks 

Anchorage 

Anchorage 

Birmingham 
Pine  Hill 
Auburn 

Redstone  Arsenal 
Redstone  Arsenal 

Tuscaloosa 
Birmingham 

Russellville 


Tempe 
Tonopah 

Tucson 

Mesa 

Scottsdale 

Phoenix 

Phoenix 

Phoenix 

Scottsdale 
Scottsdale 


Corona 

Santa  Fe  Springs 
San  Francisco 
Cupertino 

Carmichael 

Carmichael 

Berkeley 

Berkeley 

Irvine 

San  Francisco 

Sunnyvale 

City  of  Industry 

Gardena 

Paramount 

Fontana 

Anaheim 


AK 
AK 
AK 


AL 

AL 

AL 
AL 
AL 

AL 
AL 

AR 


AZ 
AZ 

AZ 
AZ 
AZ 
AZ 
AZ 
AZ 

AZ 
AZ 


CA 
CA 
CA 
CA 

CA 
CA 
CA 
CA 
CA 
CA 
CA 
CA 
CA 
CA 
CA 
CA 


PLM 
PLM 
PLM 


PLM 

Commercial 
PLM 

Calibration 
Dosimetry 

PLM 
Fasteners 

PLM 


PLM 

Dosimetry 

PLM 
PLM 
PLM 
PLM 
TEM 
PLM 

FCC 

MIL-STD-462 


Fasteners 
Fasteners 
PLM 
FCC 

PLM 

TEM 

PLM 

TEM 

FCC 

PLM 

FCC 

Carpet 

Fasteners 

Fasteners 

PLM 

Fasteners 


NVLAP  1999  DIRECTORY  -  Page  C3 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  C.  LISTING  BY  STATE/COUNTRY  -  continued 


LABORATORY  NAME 

NVLAP 
LAB  CODE 

CITY 

STATE/ 
COUNTRY 

FIELD 

Cisco  Systems,  Inc. 

200114-0 

San  Jose 

CA 

FCC 

City  of  Los  Angeles  Department  of  Water  and  101111-0 

Los  Angeles 

CA 

PLM 

Power 

City  of  San  Jose,  Materials  Testing 

100325-0 

San  Jose 

CA 

Construction 

Laboratory 

Clark  Seif  Clark,  Inc. 

200324-0 

Chatsworth 

CA 

PLM 

Compatible  Electronics,  Inc. 

200063-0 

Agoura 

CA 

FCC 

Compliance  Eng.  Svces,  Inc.,  Compliance 

200065-0 

Sunnyvale 

CA 

FCC 

Certification  Services 

Compliance  Engineering  Services,  Inc.  - 

200064-0 

Sunnyvale 

CA 

FCC 

Taiwan 

Concord  Analysis,  Inc. 

101884-0 

Chatsworth 

CA 

PLM 

CT&E  Environmental  Services  Inc. 

200067-0 

San  Diego 

CA 

PLM 

CTL  Environmental  Services 

101216-0 

Harbor  City 

CA 

PLM 

Department  of  Environmental  Health 

101530-0 

San  Diego 

CA 

PLM 

Industrial  Hygiene  Laboratory 

Design  for  Health,  Inc. 

101864-0 

San  Diego 

CA 

PLM 

Durkee  Testing  Laboratories,  Inc. 

200178-0 

Paramount 

CA 

Fasteners 

Electro  Magnetic  Test,  Inc. 

200147-0 

Mountain  View 

CA 

FCC 

Electronic  Compliance  Laboratories,  Inc. 

200089-0 

Sunnyvale 

CA 

FCC 

Elliott  Laboratories,  Inc. 

200069-0 

Sunnyvale 

CA 

FCC 

EMC  Compliance  Mgmt  Group,  dba 

200068-0 

Mountain  View 

CA 

FCC 

Turntech  Scientific  &  Instr.,  Inc. 

EMCE  Engineering,  Inc. 

200092-0 

Fremont 

CA 

FCC 

EMS  Laboratories,  Inc. 

101218-0 

Pasadena 

CA 

PLM 

EMS  Laboratories,  Inc. 

101218-0 

Pasadena 

CA 

TEM 

EMSL  Analytical,  Inc. 

101048-3 

San  Mateo 

CA 

PLM 

EMSL  Analytical,  Inc. 

101048-3 

San  Mateo 

CA 

TEM 

ENCORP 

200013-0 

El  Segundo 

CA 

PLM 

Fastener  Innovation  Technology,  Inc. 

200179-0 

Gardena 

CA 

Fasteners 

Federal  Manufacturing  Corp. 

200279-0 

Chatsworth 

CA 

Fasteners 

Forensic  Analytical  Specialties,  Inc. 

101459-0 

Hayward 

CA 

PLM 

Forensic  Analytical  Specialties,  Inc. 

101459-0 

Hayward 

CA 

TEM 

Forensic  Analytical  Specialties,  Inc. 

101459-1 

Rancho  Domingues 

CA 

PLM 

Garwood  Laboratories,  Inc. 

200119-0 

Placentia 

CA 

FCC 

Geoscience  Ltd. 

100142-0 

San  Diego 

CA 

Thermal  Insl. 

Hadd-Co  Inspection  Lab 

200326-0 

Torrance 

CA 

Fasteners 

Health  Science  Associates 

101384-0 

Los  Alamitos 

CA 

PLM 

Hewlett  Packard,  Product  Test  Lab,  San 

200138-0 

San  Diego 

CA 

FCC 

Diego 

Hi-Tech  Environmental  and  Laboratory 

102013-0 

Cypress 

CA 

PLM 

Services 

Hygeia  Laboratories  Inc. 

102116-0 

Sierra  Madre 

CA 

PLM 

Hygeia  Laboratories  Inc. 

102116-0 

Sierra  Madre 

CA 

TEM 

ICN  Dosimetry  Service,  Div.  of  ICN 

100555-0 

Costa  Mesa 

CA 

Dosimetry 

Biomedicals,  Inc. 

Incotec  Laboratory 

200339-0 

Mojave 

CA 

Fasteners 

InfoGard  Laboratories,  Inc. 

100432-0 

San  Luis  Obispo 

CA 

Cryptographic 

Inland  Foundation  Engineering,  Inc. 

100406-0 

San  Jacinto 

CA 

Construction 

Intertek  Testing  Services 

200201-0 

Menlo  Park 

CA 

FCC 

Intertek  Testing  Services  NA  Inc. 

200297-0 

Laguna  Niguel 

CA 

FCC 

ITEK  Enviro  Services,  Inc. 

200032-0 

South  San  Francisco 

CA 

PLM 

NVLAP  1999  DIRECTORY  -  Page  C4 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  C.  LISTING  BY  STATE/COUNTRY  -  continued 


T  ARORATORYNAMF 

NVLAP 

I . .  V I  >  V  V  / 1.  /  i\ 

PTTV 
v  I  1  1 

STATE/ 

PATTNTRV 

i  11,1,1/ 

J.W.  Mfg.  DBA  Van  Petty  Mfg. 

a  a c  a 

200225-0 

Newbury  Park 

CA 

Fasteners 

Kellco  Services,  Inc. 

1  A  1  1  T  1  A 

101331-0 

Hayward 

CA 

PLM 

LA  Testing 

200232-0 

S.  Pasadena 

CA 

PLM 

T     A     T  i.1  

LA  Iesting 

200232-0 

S.  Pasadena 

CA 

TEM 

Lockheed  Martin  Technical  Operations 

1  ac.  a  1  *7  a 
IUjOI  /-U 

Sunnyvale 

CA 

Calibration 

Los  Angeles  Harbor  Department  Testing 

102020-0 

Wilmington 

CA 

PLM 

Laboratory 

Los  Angeles  Unified  School  District 

1  A 1  Z f\>Z  A 

1U1 jOj-U 

Los  Angeles 

a 

CA 

DT  TV.  A 

Los  Angeles  Unmed  School  District 

1  A  1  C  AC  A 

101505-0 

Los  Angeles 

CA 

TEM 

M&M  Manufacturing  Corportation 

1 A  A 1  C  f  A 

200356-0 

Chino 

CA 

Fasteners 

MACS  Lab,  Inc. 

1  A  1  Ct  A  O  A 

101948-0 

Santa  Clara 

CA 

PLM 

MACS  Lab,  Inc. 

1  A  1  A  A  O  A 

101948-0 

Santa  Clara 

CA 

TEM 

Micro  Analytical  Laboratories,  Inc. 

1  A  1  0  n  a 

101872-0 

Emeryville 

CA 

PLM 

X  A"               A          1      '  '■        1    T       1_  T 

Micro  Analytical  Laboratories,  Inc. 

1  A  1  A  T>  /~i 

101872-0 

Emeryville 

CA 

TEM 

Micro  Analytical  Laboratories,  Inc. 

*>AAAC  A  A 

200054-0 

San  Francisco 

CA 

PLM 

Micron  Environmental  Labs 

2002^4-0 

Arcadia 

CA 

PLM 

MQS  Inspection,  Inc.  Magnetic  Particle  & 

200.3 14-0 

Santa  Fe  Springs 

CA 

Fasteners 

Liquid  Penetrant  Exam. 

NAILC  International,  Inc. 

1  A1  1  f  f  A 

101 155-0 

uarden  Grove 

CA 

PLM 

National  Analytical  Laboratories,  Inc. 

1 A1AOA  A 

102080-0 

Roseville 

CA 

PLM 

National  Econ  Corporation 

1  AOA/^O  A 

1 U2002-U 

Tustin 

CA 

DT  \A 

rLM 

\r  1  TT  T/^~\1  mXTC  T~ 'TV  A  J  T  „T-   T  ~1  /Da 

NAWCWPNS  EMI  Lab,  China  Lake/Pt. 

O  A  A  1  A  A  A 

200199-0 

China  Lake 

CA 

M1L-S  ID-462 

Mugu,  CA 

xi  1  _  rrrT  r  

Nemko  EESI,  Inc. 

1 A  A  1  1  £  A 

200 l 16-0 

San  Diego 

CA 

FCC 

Northern  Telecom  Inc. 

1  A  A  A  1  1  A 

1 004 1 1 -0 

Santa  Clara 

CA 

rCC 

NYLUK.  rastener  Corporation 

2002/2-0 

Anaheim 

CA 

Fasteners 

Pacific  Gas  &  Electric  Company,  Diablo 

1  A  AC  1  *7  A 

100537-0 

Avila  Beach 

CA 

Dosimetry 

Canyon  Nuclear  Power  Plant 

Patriot  Environmental  Laboratory  Services 

1 A A1 CO  A 

200358-0 

1--'  1  y-i  

Garden  Grove 

CA 

DT  TV  A 

PLM 

PB  Fasteners 

1AA 1  O  A  A 

200139-0 

Gardena 

CA 

r  asteners 

PDE  Laboratories 

IAAAOI  A 

200082-0 

San  Clemente 

CA 

FCC 

Precision  Micro-Analysis,  Inc. 

1  OIdjjo-O 

Sacramento 

a 

CA 

DT  \A 
PLM 

dot 

PSI 

1  A 1  ATA  A 

101970-0 

Brea 

/-i  a 

CA 

DT  \  A 

PLM 

Radiation  Detection  Company 

1 AAC 1 1  A 

100512-0 

Sunnyvale 

O  A 

CA 

Dosimetry 

Radiation  Technology,  Inc. 

200086-0 

San  Jose 

A 

CA 

rCC 

Republic  Fastener  Manufacturing 

200195-0 

Newbury  Park 

CA 

Fasteners 

Resources,  Applications,  Designs  &  Control,  100261-0 

Long  Beach 

CA 

Thermal  Insl. 

Inc.  (RADCO) 

RJ  Lee  Group,  Inc. 

101208-2 

San  Leandro 

/~"  A 

CA 

DT  \A 
PLM 

RJ  Lee  Group,  Inc. 

101208-2 

San  Leandro 

CA 

1  LM 

Rockford  Engineering  Services,  Inc. 

200172-0 

Sunol 

O  A 

CA 

rCC 

Saturn  Fasteners,  Inc. 

200327-0 

Burbank 

CA 

r  asteners 

SCILAB  California,  Inc. 

200346-0 

Carson 

CA 

PLM 

SCILAB  California,  Inc. 

200346-0 

Carson 

(~*  A 

CA 

TEA  A 

1  LM 

SGI  EMC  Laboratories 

200233-0 

Mountain  View 

A 

CA 

rCC 

Sony  Electronics  Inc.  Product  Quality 

200312-0 

San  Diego 

a 

CA 

rCC 

Division  EMC  Group 

South  Coast  Air  Quality  Management  District  101567-0 

Diamond  Bar 

CA 

DT  \A 

rLM 

Southern  California  Edison 

100506-0 

PA 

i-'UoiiiicLry 

Southern  California  Edison  Company 

105014-0 

Westminster 

CA 

Calibration 

SPS  Technologies  Aerospace  Product 

200298-0 

Santa  Ana 

m  ci  c t *o to  ore 

r  aMciicrb 

Division 

NVLAP  1999  DIRECTORY  -  Page  C5 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  C.  LISTING  BY  STATE/COUNTRY  -  continued 


LABORATORY  NAME 

NVLAP 
LAB  CODE 

CITY 

STATE/ 
COUNTRY 

FIELD 

St.  of  California,  Bur.  of  Home  Furnishings 

100251-0 

North  Highlands 

CA 

Thermal  Insl. 

&  Thermal  Insulation 

Sun  Microsystems,  Inc.  EMC  Testing 

200363-0 

Palo  Alto 

CA 

FCC 

The  Monadnock  Company 

200268-0 

City  of  Industry 

CA 

Fasteners 

Thomas  Lighting  Accent  Division 

200155-0 

Los  Angeles 

CA 

Lighting 

Photometric  Laboratory 

TUV  Product  Service,  Inc. 

100268-0 

San  Diego 

CA 

FCC 

TUV  Product  Service,  Inc. 

100268-0 

San  Diego 

CA 

MIL-STD-462 

Underwriters  Laboratories 

200252-0 

Santa  Clara 

CA 

FCC 

Universal  Compliance  Laboratories 

200117-0 

San  Jose 

CA 

FCC 

Western  Analytical  Laboratory 

200037-0 

Burbank 

CA 

PLM 

Western  Electro-Acoustic  Lab.,  Inc. 

100256-0 

Santa  Monica 

CA 

Acoustics 

CO 

Alpine  Consulting,  Inc. 

102089-0 

Colorado  Springs 

CO 

PLM 

Analytica  Solutions,  Inc. 

101086-0 

Broomfield 

CO 

PLM 

Analytica  Solutions,  Inc. 

101086-0 

Broomfield 

CO 

TEM 

ATC  Environmental,  Inc. 

102031-0 

Englewood 

CO 

PLM 

Compaq  Computer  Corp.  EMC  Test  Facility 

200078-0 

Colorado  Springs 

CO 

FCC 

Criterion  Technology 

100396-0 

Rollinsville 

CO 

FCC 

DCM  Science  Laboratory,  Inc. 

101258-0 

Wheat  Ridge 

CO 

PLM 

Denver  Instrument  Co.  Weight  Lab 

200106-0 

Arvada 

CO 

Calibration 

FRS  Geotech,  Inc. 

102078-0 

Denver 

CO 

PLM 

Johns  Manville  Technical  Center 

100425-0 

Littleton 

CO 

Acoustics 

Johns  Manville  Technical  Center 

100425-0 

Littleton 

CO 

Thermal  Insl. 

National  Environmental  Reference 

101593-0 

Denver 

CO 

PLM 

Laboratory 

Reservoirs  Environmental  Services,  Inc. 

101896-0 

Denver 

CO 

PLM 

Reservoirs  Environmental  Services,  Inc. 

101896-0 

Denver 

CO 

TEM 

Storagtek  Open  Area  Test  Site 

200251-0 

Louisville 

CO 

FCC 

TUV  Product  Service,  Inc. 

100271-1 

Boulder 

CO 

FCC 

U.S.  EPA  -  National  Enforcement 

101703-0 

Denver 

CO 

PLM 

Investigations  Center 

CT 

ChemScope,  Inc. 

101061-0 

North  Haven 

CT 

PLM 

Combustion  Engineering,  Inc. 

100563-0 

Windsor 

CT 

Dosimetry 

Eastern  Materials  Testing  Lab  a  division  of 

100315-0 

New  Britain 

CT 

Construction 

Jaworski  Geotech 

Electric  Boat  Corp/A  General  Dynamics  Co. 

100560-0 

Groton 

CT 

Dosimetry 

Radiological  Ctrl.  Dept 

EnviroMed  Services,  Inc. 

101514-0 

New  Haven 

CT 

PLM 

Fairfield  Testing  Laboratory,  Inc. 

100317-0 

Stamford 

CT 

Construction 

HYGENIX,  INC. 

101199-0 

Stamford 

CT 

PLM 

Independent  Materials  Testing  Laboratories, 

100316-0 

Plainville 

CT 

Construction 

Inc. 

Materials  Testing,  Inc. 

100320-0 

Milford 

CT 

Construction 

Mystic  Air  Quality  Consultants,  Inc. 

101282-0 

Groton 

CT 

PLM 

Northeast  Utilities  Dosimetry  Laboratory 

100540-0 

Newington 

CT 

Dosimetry 

Pratt  &  Whitney  Materials  Control 

200336-0 

East  Hartford 

CT 

Fasteners 

Laboratory 

PSI,  Inc. 

100319-0 

North  Haven 

CT 

Construction 

Special  Testing  Laboratories,  Inc. 

100308-0 

Bethel 

CT 

Construction 

NVLAP  1999  DIRECTORY  -  Page  C6 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  C.  LISTING  BY  STATE/COUNTRY  -  continued 


LABORATORY  NAME 

NVLAP 
LAB  CODE 

CITY 

STATE/ 
COUNTRY 

FIELD 

State  of  Connecticut 

101237-0 

Hartford 

CT 

PLM 

Test-Con  Incorporated 

200018-0 

Danbury 

CT 

Construction 

TRC  Environmental  Corporation 

101424-0 

Windsor 

CT 

PLM 

Tri-State  Materials  Testing  Lab,  Inc. 

2000 l 0-0 

Newington 

CT 

Construction 

TUV  Rheinland  of  North  America,  Inc. 

2001H-0 

Newtown 

CT 

FCC 

DE 

Batta  Laboratories,  Inc. 

I0l 032-0 

Newark 

DE 

PLM 

Batta  Laboratories,  Inc. 

101032-0 

Newark 

DE 

TEM 

Environmental  Testing,  Inc. 

101848-0 

Middletown 

DE 

PLM 

FL 

Advanced  Industrial  Hygiene  Services,  Inc. 

101006-0 

Miami 

FL 

PLM 

American  Asbestos  Laboratories,  Inc. 

101775-0 

Miami 

FL 

PLM 

Apollo  Environmental,  Inc. 

101871-0 

Gibsonton 

FL 

PLM 

ASC  geoscience,  inc. 

2003 l 6-0 

Lakeland 

FL 

Construction 

Celotex  Technical  Center 

1 004 1 7-0 

St.  Petersburg 

FL 

Acoustics 

Celotex  Technical  Center 

1 004 1 7-0 

St.  Petersburg 

FL 

Thermal  Insl. 

Comprehensive  Health 

101759-0 

Kennedy  Space  Center 

FL 

PLM 

Services-Environmental  Health  PLM 

Laboratory 

Dove  Environmental  Corporation 

l 02053-0 

Miami 

FL 

PLM 

E.  M.  Analytical,  Inc. 

101902-0 

Dania 

FL 

TEM 

EMSL  Analytical,  Inc. 

200204-0 

N.  Miami  Beach 

FL 

PLM 

EMSL  Analytical,  Inc. 

200204-0 

N.  Miami  Beach 

FL 

TEM 

Florida  Power  &  Light  Company 

l 00544-0 

Juno  Beach 

FL 

Dosimetry 

GLE  Associates,  Inc. 

102003-0 

Tampa 

FL 

PLM 

Henderson/Longfellow  Associates,  Inc. 

l 02077-0 

St.  Petersburg 

FL 

PLM 

Hygeia  Laboratories,  Inc. 

200335-0 

Miami 

FL 

PLM 

Hygeia  Laboratories,  Inc. 

200335-0 

Miami 

FL 

TEM 

Law  Engineering  and  Environmental 

101515-0 

Tampa 

FL 

PLM 

Services,  Inc. 

Law  Engineering  and  Environmental 

101515-1 

Miami  Lakes 

FL 

PLM 

Services,  Inc. 

Micro  Analytical  Laboratories,  Inc. 

10H51-0 

Gainesville 

FL 

PLM 

Micro  Analytical  Laboratories,  Inc. 

10H51-0 

Gainesville 

FL 

TEM 

Motorola  PPG  Compliance  Laboratory 

2003 l 8-0 

Boynton  Beach 

FL 

FCC 

Occupational  Health  Conservation,  Inc. 

l 02050-0 

Jacksonville 

FL 

PLM 

Paradyne  Corporation 

200125-0 

Largo 

FL 

FCC 

PRIMES  (Preflight  Integration  of  Munitions 

l 00422-0 

Eglin  Air  Force  Base 

FL 

MIL-STD-462 

&  Electronic  Systems) 

Product  Safety  Engineering,  Inc. 

200074-0 

Dade  City 

FL 

FCC 

R.  Robinson  Analytical  Services,  Inc. 

102041-0 

Pensacola 

FL 

PLM 

GA 

American  Carpet  Laboratories,  Inc. 

l 00 l 39-0 

Ringgold 

GA 

Carpet 

Analytical  Environmental  Services,  Inc. 

102033-0 

Atlanta 

GA 

PLM 

Beaulieu  of  America  -  Carpet  Testing  Lab 

100190-0 

Dalton 

GA 

Carpet 

Cape  Environmental  Management,  Inc. 

102H1-0 

Atlanta 

GA 

PLM 

Clayton  Laboratory  Services 

10H25-0 

Kennesaw 

GA 

PLM 

v-'iayiun  i— <<xu\ji  clikji  y  oti  viv^to 

I0l 125-0 

l  ■  '  i  i  . — '  \j 

Kennesaw 

GA 

TEM 

Commercial  Testing  Company 

1 00 1 20-0 

Dalton 

GA 

Carpet 

Cooper  Lighting  -  Metalux  Research 

200050-0 

Americus 

GA 

Lighting 

NVLAP  1999  DIRECTORY  -  Page  C7 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  C.  LISTING  BY  STATE/COUNTRY  -  continued 


LABORATORY  NAME 

XTA/T    A  11 

IN  VLAr 
LAB  CODE 

CITY 

CT1  A  HPT?  / 

S I A  lE/ 
COUNTRY 

FIELD 

T  ahoratorif*5; 

EMSL  Analytical,  Inc. 

101048-1 

1  U  1  W  i  U  I 

A  tlanta 

1  V  Hull  Id 

GA 

Pi  M 

EMSL  Analytical,  Inc. 

101048-1 

Atlanta 

GA 

TEM 

Geo-Analytical  Services,  Inc. 

102082-0 

Atlanta 

GA 

PLM 

Geo-Analytical  Services,  Inc. 

102082-0 

Atlanta 

GA 

TEM 

Georgia  Power  Company/Enviro.  Affairs, 

100551-0 

i  i  i  y  i  iiu 

GA 

L-'UoIll  It  LI  y 

Enviro.  Lab-Dosimetry 

Hayes  Microcomputer  Products,  Inc. 

900103-0 

A  Han  t  a 

1  V  1 1  Cl-1 1 1  Cl 

GA 

FCC 

Hyseia  Laboratories,  Inc. 

10^087-0 

Marietta 

1  t  1  Cll  ivi  lu 

GA 

PLM 

Indpnpndpnt  Tpxtilp  Tp^tmQ  ^prvirp  Inr 

lllUVL/VllUWlll     1  VAll  IV     1  V  Jill  1  L,    Uvl  V  1  Vv  V  ,  111V. 

100166-0 

1  \J \J  I  \J\J  \J 

Dallnn 

L/ul  LU1 1 

VJ  A 

V,  CU  LfCL 

Tntprtpk  Tp^finc*  Sprvirp^  TvJ  A  Trie 

ill  Ivl               1  vOUllg   Uv  1  V  Ivvj    1*1  .  Y    1  1  1  v_  . 

1 00409-0 

FCC 

Lithonia  Testing  Laboratories 

200007-0 

Conyers 

GA 

Materials  Analytical  Services,  Inc. 

101235-0 

Suwanee 

GA 

PLM 

Materials  Analytical  Services,  Inc. 

101235-0 

Suwanee 

GA 

TEM 

Mohawk  Industries,  Inc.-  Lyerly  Plant 

100156-0 

Lverlv 

GA 

Carpet 

Professional  Testing  Laboratory,  Inc. 

100297-0 

Dalton 

GA 

Carpet 

Queen  Carpet  Test  Laboratory 

100429-0 

Dalton 

GA 

Carpet 

Shaw  Industries,  Inc.,  Central  Laboratory 

100193-0 

Dalton 

GA 

Camet 

CXI  UtL 

Operations 

TSi,  Testing  Services,  Inc. 

100108-0 

Dalton 

GA 

Carpet 

United  States  I  echnologies,  Inc. 

200162-0 

Alpharetta 

GA 

FCC 

World  Carpets,  Inc. 

i  aa  1  m  a 

l 00 l 97-0 

Dalton 

GA 

Carpet 

HI 

EnvironMETeo  Services  Inc. 

101807-0 

Waipahu 

HI 

PLM 

Muranaka  Environmental  Consultants,  Inc. 

1  AT AO r  A 

1 020o5-0 

Honolulu 

LJ  I 

H 1 

rLM 

White  Environmental  Consultants,  Inc. 

taaica  n 

Honolulu 

i  j  i 

rLM 

IA 

Tntemipc  Tprhnnlopips  Comoratinn  NnranH 

1  lliv  1  11  IV  w      1  VVIIIIWIUt,IVO    V_-  \J  1  UU1  UlIUll,    1  1  Ul  U1IU 

100769-0 

[A 

FCC 

Mobile  System  Division 

Iowa  Environmental  Services,  Inc. 

101990-0 

Des  Moines 

IA 

PLM 

Liberty  Labs,  Inc. 

200123-0 

Kimballton 

IA 

Calibration 

University  (State)  Hygienic  Laboratory 

I  Ai  TOO  f\ 

101288-0 

Iowa  City 

LA 

PLM 

University  (State)  Hygienic  Laboratory 

101288-0 

Iowa  City 

LA 

1 LM 

ID 

Lockheed  Martin  Idaho  Tech.  Co.,  Standards  2001 15-0 

Idaho  rails 

ID 

Calibration 

and  Calibration  Lab. 

IL 

Aires  Consulting  Group,  Inc. 

101014-0 

R  c\  t  a  v  1 9 

LJala.  via 

IL 

PLM 

Aires  Consulting  Group,  Inc. 

101014-0 

R  C\  t  a  \/ 1  a 
Udldv  la 

IL 

TEM 

Analyticalab 

101727-0 

Willow  Snrincc 

IL 

PLM 

Arden  Fasteners 

200187-0 

A  HHi  ?nn 

I\  vi  vi  1  oVJ  1 1 

IL 

pQctpnArs 

Beling  Consultants,  Inc. 

101356-0 

Moline 

IL 

PLM 

Carnow,  Conibear  &  Associates  Ltd. 

101039-0 

Chicago 

IL 

PLM 

Carnow,  Conibear  &  Associates  Ltd. 

101039-0 

Chicago 

IL 

TEM 

Casey  Products,  Inc. 

200278-0 

Lisle 

IL 

Fasteners 

Clinton  Power  Station 

100570-0 

Clinton 

IL 

Dosimetry 

ComEd  -  TLD  Processing  Lab  -  CTEAM 

100541-0 

Bolingbrook 

IL 

Dosimetry 

Facility 

D.L.S.  Electronic  Systems,  Inc. 

100276-0 

Wheeling 

IL 

FCC 

NVLAP  1999  DIRECTORY  -  Page  C8 

(See  'How  To  Use  This  Directory'  on  page  ' 

INDEX  C.  LISTING  BY  STATE/COUNTRY  -  continued 


LABORATORY  NAME 

NVLAP 
LAB  CODE 

CITY 

STATE/ 
COUNTRY 

FIELD 

Elite  Electronic  Engineering  Company 

100278-0 

Downers  Grove 

IL 

FCC 

Elite  Electronic  Engineering  Company 

100278-0 

Downers  Grove 

IL 

MIL-STD-462 

EMSL  Analytical  Mobile  Laboratory 

200344-0 

Chicago 

IL 

PLM 

EMSL  Analytical  Mobile  Laboratory 

200344-0 

Chicago 

.  IL 

TEM 

Flexible  Products  Company 

100210-0 

Joliet 

IL 

Thermal  Insl. 

Hygieneering,  Inc. 

101997-0 

Willowbrook 

IL 

PLM 

JMS  Environmental  Associates,  Ltd. 

102012-0 

Westmont 

IL 

PLM 

JMS  Environmental  Associates,  Ltd. 

102012-0 

Westmont 

IL 

TEM 

Landauer,  Inc. 

100518-0 

Glenwood 

IL 

Dosimetry 

MacLean  Fasteners  -  QC  Laboratory 

200153-0 

Mundelein 

IL 

Fasteners 

Midwest  Laboratories,  Inc. 

101894-0 

Countryside 

IL 

PLM 

Midwest  Laboratories,  Inc. 

101894-0 

Countryside 

IL 

TEM 

Modern  Plating  Corporation 

200320-0 

Freeport 

IL 

Fasteners 

Northwestern  Steel  and  Wire  Company 

200224-0 

Sterling 

IL 

Fasteners 

NYLOK  Fastener  Corporation  -  Chicago 

200275-0 

Lincolnwood 

IL 

Fasteners 

Testing  Laboratory 

Philip  Environmental  Services  Corp. 

101192-0 

Columbia 

IL 

PLM 

Prospect  Testing  Labs,  Inc. 

200328-0 

Des  Plaines 

IL 

Fasteners 

RCM  Laboratories,  Inc. 

101853-0 

Countryside 

IL 

PLM 

Riverbank  Acoustical  Laboratories 

100227-0 

Geneva 

IL 

Acoustics 

Rockford  Bolt  &  Steel  Co. 

200255-0 

Rockford 

IL 

Fasteners 

Rocknel  Fastener  Inc. 

200307-0 

Rockford 

IL 

Fasteners 

STAT  Analysis  Corporation 

101202-0 

Chicago 

IL 

PLM 

STAT  Analysis  Corporation 

101202-0 

Chicago 

IL 

TEM 

STS  Consultants,  Ltd. 

100191-0 

Vernon  Hills 

IL 

Construction 

TEM,  Incorporated 

101130-0 

Glen  Ellyn 

IL 

PLM 

TEM,  Incorporated 

101130-0 

Glen  Ellyn 

IL 

TEM 

Underwriters  Laboratories  Inc. 

100414-0 

Northbrook 

IL 

FCC 

Underwriters  Laboratories  Inc. 

100414-0 

Northbrook 

IL 

Thermal  Insl. 

United  Analytical  Services,  Inc. 

101732-0 

Hillside 

IL 

PLM 

United  Steel  and  Fasteners  Inc. 

200341-0 

Itasca 

IL 

Fasteners 

USG  Research-Systems  Evaluation 

200132-0 

Libertyville 

IL 

Acoustics 

Laboratory 

IN 

ACM  Environmental,  Inc. 

101977-0 

South  Bend 

IN 

PLM 

Aearo  Company,  E  A  RCAL  Acoustical 

100374-0 

Indianapolis 

IN 

Acoustics 

Laboratory 

EMSL  Analytical,  Inc. 

200188-0 

Indianapolis 

IN 

PLM 

EMSL  Analytical,  Inc. 

200188-0 

Indianapolis 

IN 

TEM 

ESG  Laboratories 

102029-0 

Indianapolis 

IN 

PLM 

Fuji  Component  Parts  USA,  Inc. 

200180-0 

Indianapolis 

IN 

Fasteners 

Indiana  Automotive  Fasteners,  Inc. 

200150-0 

Greenfield 

IN 

Fasteners 

Knauf  Fiber  Glass  Research  Laboratory 

100248-0 

Shelbyville 

IN 

Thermal  Insl. 

Micro  Air,  Inc. 

101221-0 

Indianapolis 

IN 

PLM 

Pace  Analytical 

101265-0 

Indianapolis 

IN 

PLM 

Pace  Analytical 

101265-0 

Indianapolis 

IN 

TEM 

Raytheon  Technical  Services  Co.  EMI 

200317-0 

Indianapolis 

IN 

MIL-STD-462 

Laboratory 

Rightway  Fasteners,  Inc. 

200210-0 

Columbus 

IN 

Fasteners 

NVLAP  1999  DIRECTORY  -  Page  C9 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  C.  LISTING  BY  STATE/COUNTRY  -  continued 
LABORATORY  NAME 


NVLAP 

LAB  CODE  CITY 


STATE/ 
COUNTRY 


FIELD 


KS 

Asbestos  Consulting  &  Testing  (ACT)  101649-0  Lenexa 

MAC  Fasteners,  Inc.  200141-0  Ottawa 

PSI  101342-0  Lawrence 

Rogers  Labs,  Inc.  200087-0  Louisburg 

KY 

Analytical  Industries,  Inc.  101855-0  Paducah 

GE  Owensboro  Test  Laboratory  200305-0  Owensboro 

Guardian  Laboratories  101399-0  Louisville 

Intertek  Testing  Services  NA  Inc.  100274-0  Lexington 

McCall  and  Spero  Environmental,  Inc.  101895-0  Louisville 

McCall  and  Spero  Environmental,  Inc.  101895-0  Louisville 

MRS.,  Analytical  Laboratory,  Inc.  1021 13-0  Louisville 

TWN  Fastener,  Inc.  200194-0  Bowling  Green 

LA 

EMSL  Analytical,  Inc.  200375-0  Baton  Rouge 

EMSL  Analytical,  Inc.  200375-0  Baton  Rouge 

Entergy  Operations,  Inc.  100535-0  Taft 

Louisiana  Department  of  Environmental  102000-0  Baton  Rouge 
Quality  Microanalytical  Lab 

MA 

Acton  Environmental  Testing,  dba  National    100347-0  Boxborough 
Technical  Systems 

Chomerics  Test  Services  (CTS)  100296-0  Woburn 

Covino  Environmental  Associates,  Inc.  101781-0  Woburn 

Curtis-Straus  LLC  200057-0  Littleton 

Data  General  Corporation  100339-0  Westboro 

Digital  Regulatory  Engineering  and  Testing    100413-0  Marlboro 
Services 

Duke  Engineering  and  Services  100524-0  Bolton 
Environmental  Laboratory 

Holometrix  -  Micromet  100113-0  Bedford 

Hub  Testing  Laboratory,  Inc.  101045-0  Waltham 

Hygeia  Laboratories,  Inc.  101011-0  Woburn 

Hygeia  Laboratories,  Inc.  101011-0  Woburn 

Hygienetics  Laboratory  Services  101147-0  Boston 

Hygienetics  Laboratory  Services  101147-0  Boston 

Instron  Force  Calibration  Laboratory  105023-0  Canton 

Integrity  Design  &  Test  Services,  Inc.  200004-0  Littleton 

Intertek  Testing  Services  NA  Inc.  100270-0  Boxborough 

Intertek  Testing  Services  N A  Inc.  100270-0  Boxborough 

Motorola  Product  Quality  Assurance  200005-0  Mansfield 
Laboratory 

Osram  Sylvania  Inc.,  Test  &  Measurements    100403-0  Beverly 
Laboratory 

ProScience  Analytical  Services,  Inc.  200090-0  Woburn 

ProScience  Analytical  Services,  Inc.  200090-0  Wobum 

Quest  Engineering  Solutions,  Inc.  200036-0  N.  Billerica 

Robbins  Manufacturing  Co.,  Inc.  200161-0  Fall  River 


KS 
KS 
KS 
KS 


KY 
KY 
KY 
KY 
KY 
KY 
KY 
KY 


LA 
LA 
LA 
LA 


MA 

MA 
MA 
MA 
MA 
MA 

MA 

MA 
MA 
MA 
MA 
MA 
MA 
MA 
MA 
MA 
MA 
MA 

MA 

MA 
MA 
MA 
MA 


PLM 
Fasteners 
PLM 
FCC 


PLM 

Electric  Motors 

PLM 

FCC 

PLM 

TEM 

PLM 

Fasteners 


PLM 
TEM 
Dosimetry 
PLM 


MIL-STD-462 

FCC 
PLM 
FCC 
FCC 
FCC 

Dosimetry 

Thermal  Insl. 

PLM 

PLM 

TEM 

PLM 

TEM 

Calibration 

FCC 

FCC 

MIL-STD-462 
FCC 

Lighting 

PLM 
TEM 
FCC 

Fasteners 


NVLAP  1999  DIRECTORY  -  Page  C10 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  C.  LISTING  BY  STATE/COUNTRY  -  continued 


LABORATORY  NAME 

NVLAP 
LAB  CODE 

CITY 

STATE/ 
COUNTRY 

FIELD 

SCILAB  BOSTON,  Inc. 

102079-0 

East  Weymouth 

MA 

PLM 

SCILAB  BOSTON,  Inc. 

102079-0 

East  Weymouth 

MA 

TEM 

Severn  Trent  Laboratories  (MA) 

101005-0 

N.  Billerica 

MA 

PLM 

Severn  Trent  Laboratories  (MA) 

101005-0 

N.  Billerica 

MA 

TEM 

Test  Site  Services,  Inc. 

100419-0 

Marlboro 

MA 

FCC 

W.R.  Grace  &  Co. 

200258-0 

Cambridge 

MA 

Construction 

MD 

AMA  Analytical  Services,  Inc. 

101143-0 

Lanham 

MD 

PLM 

AMA  Analytical  Services,  Inc. 

101143-0 

Lanham 

MD 

TEM 

ATC  Associates  Inc. 

200250-0 

Columbia 

MD 

PLM 

Baltimore  Gas  &  Electric  Company 

100501-0 

Lusby 

MD 

Dosimetry 

CDRH  X-Ray  Calibration  Laboratory 

105018-0 

Rockville 

MD 

Calibration 

Composite  Panel  Association  (CPA) 

100418-0 

Gaithersburg 

MD 

Wood  Prod. 

DHMH-Air  Quality  Laboratory 

101523-0 

Baltimore 

MD 

PLM 

EMSL  Analytical,  Inc. 

200293-0 

Beltsville 

MD 

PLM 

EMSL  Analytical,  Inc. 

200293-0 

Beltsville 

MD 

TEM 

MET  Laboratories,  Inc. 

100273-0 

Baltimore 

MD 

FCC 

Metropolitan  Environmental  Testing  Services  200165-0 

Waldorf 

MD 

PLM 

dba  METS  Laboratories 

NAHB  Research  Center,  Inc. 

100104-0 

Upper  Marlboro 

MD 

Commercial 

NAHB  Research  Center,  Inc. 

100104-0 

Upper  Marlboro 

MD 

Thermal  Insl. 

Naval  Dosimetry  Center 

100504-0 

Bethesda 

MD 

Dosimetry 

NAWC  AD  5. 1.7.3.  EMI  Lab 

100408-0 

Patuxent  River 

MD 

MIL-STD-462 

PCTEST  Engineering  Laboratory,  Inc. 

100431-0 

Columbia 

MD 

FCC 

U.S.  Army  Center  for  Health  Promotion  and 

200044-0 

Aberdeen  Proving  Ground 

MD 

PLM 

Preventive  Medicine 

Washington  Laboratories,  Ltd. 

200066-0 

Gaithersburg 

MD 

FCC 

Windermere  Info.  Tech.  Sys. 

200084-0 

Annapolis 

MD 

FCC 

Military/Commercial  Compliance  Lab. 

ME 

Northeast  Test  Consultants 

101565-0 

Westbrook 

ME 

PLM 

MI 

AAC  Trinity,  Inc. 

101168-0 

Farmington  Hills 

MI 

PLM 

AHD 

200129-0 

Dowagiac 

MI 

FCC 

Apex  Research  Laboratory 

102118-0 

Whitmore  Lake 

MI 

PLM 

Detroit  Edison,  Fermi  2  Dosimetry 

100529-0 

Newport 

MI 

Dosimetry 

Laboratory 

Dexter  Fastener  Technologies,  Inc. 

200144-0 

Dexter 

MI 

Fasteners 

Dow  Chemical  N.  America  Foam  Products 

100103-0 

Midland 

MI 

Thermal  Insl. 

Research,  Prod.  Perf.  Lab. 

Eaton  E3  Laboratory 

100382-0 

Soufhfield 

MI 

MIL-STD-462 

EMSL  Analytical,  Inc. 

101048-4 

Ann  Arbor 

MI 

PLM 

EMSL  Analytical,  Inc. 

101048-4 

Ann  Arbor 

MI 

TEM 

ERT  Testing  Services 

101295-0 

Highland  Park 

MI 

PLM 

Fabristeel  Products  Inc. 

200329-0 

Taylor 

MI 

Fasteners 

Fibertec,  Inc. 

101510-0 

Holt 

MI 

PLM 

Multifastener  Laboratory 

200267-0 

Taylor 

MI 

Fasteners 

NSS  Technologies 

200184-0 

Plymouth 

M  1 

Fasteners 

NYLOK  Fastener  Corporation 

200273-0 

Macomb 

MI 

Fasteners 

Wilson-Garner  Company 

200136-0 

Harrison  Township 

MI 

Fasteners 

NVLAP  1999  DIRECTORY  -  Page  Cll 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  C.  LISTING  BY  STATE/COUNTRY  -  continued 


LABORATORY  NAME 

NVLAP 
LAB  CODE 

CITY 

STATE/ 
COUNTRY 

FIELD 

Wolverine  Plating  Corp. 

200230-0 

Roseville 

MI 

Fasteners 

Wonder  Makers  Environmental,  Inc. 

102065-0 

Kalamazoo 

MI 

PLM 

MN 

JUV1  riUUUCl  OalCiy  CJVlv,  L.aUUIaLUiy 

ol.  rdUl 

1V11N 

DIaUIl  IIUCIICC  V^UI  pul  allUIl 

l ni iia  o 

1 U 1 ZjH-U 

Minneapolis 

Mrs 

rLM 

DIaUIl  llllCIltX  V.  UI  pOI  aUUII 

l  ni  txa  o 

Minneapolis 

M1N 

1  clvl 

(       r\  i~rf~\  1    fl  oto    A  /"*/"iT"Q/*iif£*i"i  ft  V  I  Toot  l*  ar\  for 

v.  oniroi  udid  A.ccr cuiicU  vJoi  i  est  center 

l nni^A  o 

Arden  Hills 

uUolr 

IDJVI  KOCneSlcr  CIVIL  LaD 

TOOOQ1  o 

zuuuv  i  -u 

Rochester 

MlN 

rnp 

rLL 

insiituie  lur      viruriiTicnidi  /\ssessiTit;ni 

i o l 940  o 

Brooklyn  Park 

1V11N 

DT  \A 

Intertek  Testing  Services  NA,  Inc. 

toooaq  o 

Oakdale 

Mrs 

rLt 

LCgCUU   1  tCIlIULaT  OClvlCCo,  1I1L. 

107081  n 

1 UZUO 1  -u 

Paul 
ol.  rdUl 

PT  \A 
rLM 

\A  QY1  TY\    TpPntl  /-v  I  /~>  ("T  1      r-  Inn 

ividAini  i CLiiiiuiUKics,  inc. 

70004fi  o 

ol.  rdUl 

N/TM 

Acoustics 

IVlaAllIl   1  CLllilUlUtilCS, 

Paul 
Ol.  r  dUI 

1V11N 

Thermal  Insl. 

IVIlIlIltoUla  IVlCllUlUgy  LvdUUI  dlUI  y 

1  0S00"?  0 

1 UJUUJ-U 

<?t  Pdlll 
ol.  rdUl 

IVllN 

Calibration 

INUVa  V^UIlbUlUIlg  vJIUUU,  inc. 

i oi S4.s  o 

C  n  Q  cL'  Q 

IlaSKd 

1VTM 

Ivl  IN 

PT  \/l 
rLM 

Orfield  Laboratories,  Inc. 

200248-0 

Minneapolis 

MN 

Acoustics 

TUV  Product  Service,  Inc. 

100271-0 

New  Brighton 

MN 

FCC 

TUV  Product  Service,  Inc. 

100271-0 

New  Brighton 

MN 

MIL-STD-462 

TUV  Telecom  Services,  Inc. 

200039-0 

St.  Paul 

MN 

FCC 

MO 

A  1 1 1  c*c\ ^ i  cm  q  1  T-^TVdJCVT"1  \A  f±t~rc\  1  c\ cr\! 

r\\ neuo i^iidi  r  ivioc  i  iviciroiugy 

7001  OS  0 
ZUU 1 Uo-U 

Kansas  City 

1VHJ 

Calibration 

DUUyLUlC  1I1UUMI  laT   1  CMlIlg,  1I1L. 

1 0 1 077  0 
i  u  i  \j  i  z-u 

1  nine 
Ol.  LOUIS 

IvlKJ 

Fasteners 

Pti \/i vn t-T pqI t n  TprnnnmfTiAC  Inp 
J_>I  1  V  1 1  KJl  1  Cal  11 1   1  CdlllUI  Utlvo,  1 1  It. 

700^74  0 
zuu J  / H-yj 

Ol.  IjUUIS 

MO 

PT  M 

rLivi 

Fn  vimnmpn  tal  Hpalth  T  ^hnratnnp^ 

1  1  V  11  VJ1111      1 1  LCI  1  1  1  v,  U.  1 11 1  LCHJUI  ulUl  1L  J 

101 506-0 

r^"l  avtnn 

MO 

PLM 

K'inCTCtnn  Fn\/irr>nmprital  T  q  Hr\rQt  r\r\/ 
rv  1 1 1  t^olUl  1  L-llviiuillllt-lllal  LaUUI  alUI  y 

90004.1-0 

Let  o  OUIIUIlll 

mo 

IvlKJ 

PT  M 

Larron  Laboratory 

i  n  i  a  i  ^  o 

1 U  1  H  1  J-U 

Cape  Girardeau 

MA 
1V1(J 

PT  \A 
rLM 

Mallinckrodt  Group,  Inc. 

100503-0 

Maryland  Heights 

MO 

Dosimetry 

Microscopic  Analysis,  Inc. 

101037-0 

St.  Louis 

MO 

PLM 

OCCU-TEC,  Inc. 

102025-0 

Kansas  City 

MO 

PLM 

Union  Electric  Company,  Callaway  Plant 

100502-0 

Fulton 

MO 

Dosimetry 

MS 

Daybrite  Lighting  (Genlyte  Thomas  Group) 

200016-0 

Tupelo 

MS 

Lighting 

Photometric  Laboratory 

MT 

ILX  Lightwave  Corporation,  Optical 

200211-0 

Bozeman 

MT 

Calibration 

Calibration 

Maxim  Technologies,  Inc. 

101292-0 

Billings 

MT 

PLM 

NC 

Accredited  Environmental  Technologies,  Inc. 

200236-0 

Leland 

NC 

PLM 

Advanced  Energy,  Industrial  Energy 

200081-0 

Raleigh 

NC 

Electric  Motors 

LdUUI  dLUI  y 

A  enpefne  Annlvcic  and  Tnfnrmiitinn  ^pruipp 

Inc. 

101 7fil .0 

ruui  v-'dtvo 

wr 

IN  \-< 

PI  M 

r  Livi 

ic*t"a1  1  n     P n \/i rAnrnpn 1q1  Tt"ia 
^alUIIIld  LI  l  V  1 1  Ul  11 1 ICI 1  lal ,  1111*. 

101 76R-0 

Parv 
V^al  y 

1N\^ 

PT  M 

Carolina  Power  &  Light  Company,  Hams 

1  00 1  7  0 
1  UUJ  1  /-V 

Mom  T-T  ill 

INew  rill  I 

MA 

IN  L 

Dosimetry 

Energy  &  Enviro.  Center 

Duke  Power  Company  Dosimetry  Laboratory 

100505-0 

Charlotte 

NC 

Dosimetry 

EEC,  Inc. 

101088-0 

Raleigh 

NC 

PLM 

NVLAP  1999  DIRECTORY  -  Page  C12 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  C.  LISTING  BY  STATE/COUNTRY  -  continued 


LABORATORY  NAME 

NVLAP 
LAB  CODE 

CITY 

STATE/ 
COUNTRY 

FIELD 

EMC  International,  Inc. 

200094-0 

Youngsville 

NC 

FCC 

EMSL  Analytical,  Inc. 

102104-0 

Greensboro 

NC 

PLM 

EMSL  Analytical,  Inc. 

102104-0 

Greensboro 

NC 

TEM 

EMSL  Analytical,  Inc. 

200247-0 

Charlotte 

NC 

PLM 

IBM  Charlote  EMC  Facility 

200337-0 

Charlotte 

NC 

FCC 

IBM  RTP  PSG  EMC  Test  Labs 

200200-0 

Research  Triangle  Park 

NC 

FCC 

Law  Engineering  and  Environmental 

101226-0 

Charlotte 

NC 

PLM 

Services,  Inc. 

S&ME,  Inc. 

102075-0 

Charlotte 

NC 

PLM 

Troxler  Radiation  Monitoring  Svc.  a  div.  of 

1 AAC  CO  A 

100559-0 

Research  lnangle  Park 

XT/"* 

NC 

Dosimetry 

Troxler  Elect.  Labs 

Underwriters  Laboratories,  Inc. 

200246-0 

Research  Triangle  Park 

NC 

FCC 

ND 

A.R.C.  Laboratories,  Inc. 

101832-0 

Grand  Forks 

ND 

PLM 

NH 

Cabletron  Systems,  Inc. 

200121-0 

Rochester 

NH 

FCC 

Dames  &  Moore,  Inc. 

1  A  1  A1~i  A 

oalem 

1NH 

r  LIV1 

Retlif  Testing  Laboratories 

100267-1 

Goffstown 

NH 

FCC 

The  Scott  Lawson  Group,  Ltd. 

101228-0 

Concord 

NH 

PLM 

NJ 

Aerospace  NYLOK  -  a  subsidiary  of  the 

200271-0 

Hawthorne 

NJ 

Fasteners 

NYLOK  Fastener  Corporation 

Bell  Laboratories,  Division  Lucent 

101965-0 

Murray  Hill 

NJ 

PLM 

Technologies,  Inc. 

Craig  Environmental  Services,  Inc. 

200289-0 

Mays  Landing 

NJ 

PLM 

Duro-Test  Corporation 

200283-0 

Clifton 

NJ 

Lighting 

EAI,  Inc. 

102114-0 

Jersey  City 

NJ 

PLM 

EMSL  Analytical,  Inc. 

101048-0 

Westmont 

NJ 

PLM 

EMSL  Analytical,  Inc. 

101048-0 

Westmont 

NJ 

TEM 

EMSL  Analytical,  Inc. 

101048-2 

Piscataway 

NJ 

PLM 

EMSL  Analytical,  Inc. 

101048-2 

Piscataway 

NJ 

TEM 

EMSL  Analytical,  Inc. 

200310-0 

Carlstadt 

NJ 

PLM 

EMSL  Analytical,  Inc. 

200310-0 

Carlstadt 

NJ 

TEM 

Enviro  Techniques,  Inc. 

200024-0 

Paterson 

NJ 

PLM 

Environmental  Monitoring  &  Consulting 

101087-0 

Somerville 

NJ 

PLM 

Associates 

Fountain  Compliance  Laboratory 

200101-0 

Somerset 

NJ 

FCC 

Hillmann  Environmental  Company 

101421-0 

Union 

NJ 

PLM 

International  Asbestos  Testing  Laboratory 

101165-0 

Mt.  Laurel 

NJ 

PLM 

International  Asbestos  Testing  Laboratory 

101165-0 

Mt.  Laurel 

NJ 

TEM 

Lucent  Technologies,  Global  Product 

100275-0 

Holmdel 

NJ 

FCC 

Compliance  Lab 

NAWC-Aircraft  Div.  Lakehurst 

200222-0 

Lakehurst 

NJ 

MIL-STD-462 

Electromagnetic  Interference  Lab. 

NJSP  Calibration  Laboratory 

200006-0 

Princeton 

NJ 

Dosimetry 

PMK  Group,  Inc. 

101301-0 

Kenilworth 

NJ 

PLM 

STERIS-Isomedix  Services 

200235-0 

Whippany 

NJ 

Calibration 

NVLAP  1999  DIRECTORY  -  Page  C13 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  C.  LISTING  BY  STATE/COUNTRY  -  continued 

NVLAP  STATE/ 
LABORATORY  NAME  LAB  CODE  CITY  COUNTRY  FIELD 


NM 

Assaigai  Analytical  Laboratories,  Inc.  101457-0 

Eberline  Dosimetry  Service  100515-0 

Sandia  National  Laboratories  105002-0 

NV 

Asbestos  TEM  Laboratories,  Inc.  200 1 04-0 

Converse  Consultants  MR,  Inc.  102091-0 

U.S.  EPA  200231-0 

NY 

ABM  Environmental  Consultants,  Inc.  102015-0 

Airtek  Environmental  Corp.  102011-0 

ALAC  200323-0 

Ambient  Labs,  Inc.  101618-0 

ATC  Associates,  Inc.  101187-0 

ATC  Associates,  Inc.  1011 87-0 

Athenica  Environmental  Services,  Inc.  101958-0 

Chopra-Lee,  Inc.  200095-0 

Chopra-Lee,  Inc.  200095-0 

Con  Edison  -  ChemLab  101558-0 

Con  Edison,  Indian  Point  100538-0 

D/L  Laboratories  100252-0 

Diviersified  T.E.S.T.  Technologies,  Inc.  200340-0 

Eastern  Analytical  Services,  Inc.  101646-0 

Eastern  Analytical  Services,  Inc.  101646-0 
Eastman  Kodak  Co. -Regulatory  Compliance  2003 13-0 
Center-EMC  Facility 

EMSL  Analytical,  Inc.  101048-9 

EMSL  Analytical,  Inc.  101 048-9 

EMSL  Analytical,  Inc.  101048-10 

EMSL  Analytical,  Inc.  101048-10 

EMSL  Analytical,  Inc.  200056-0 

EMSL  Analytical,  Inc.  200056-0 

EMSL  Analytical,  Inc.  200333-0 

EMSL  Analytical,  Inc.  200333-0 

Enviro-Probe,  Inc.  101222-0 

Environmental  Testing  Laboratories,  Inc.  101937-0 

Fairway  Testing  Company,  Inc.  100340-0 

Galson  Laboratories  101375-0 
GE  Industrial  Systems,  Renewal  Services  -  200029-0 
TEMS 

Ginna  Nuclear  Station  100514-0 
IBM  Hudson  Valley  Acoustics  Laboratory  100323-0 

Industrial  Acoustics  Company,  Inc.,  100404-0 
Aero-Acoustics  Laboratory 

Intertek  Testing  Services  NA  Inc.  1 00402-0 

Intertek  Testing  Services  NA  Inc.  1 00402-0 

JLC  Environmental  Consultants,  Inc.  101953-0 

KAM  Consultants  102047-0 

KAM  Consultants  102047-0 

Lockheed  Martin  Control  Systems  EMI  200142-0 


Albuquerque 
Albuquerque 
Albuquerque 


Sparks 
Reno 

Las  Vegas 


Long  Island  City 
New  York 
Bronx 
New  York 
New  York 
New  York 
Long  Island  City 
Grand  Island 
Grand  Island 
Long  Island  City 
Buchanan 
New  York 
Groton 
Elmsford 
Elmsford 
Rochester 

New  York 
New  York 
Carle  Place 
Carle  Place 
Williamsville 
Williamsville 
Elmsford 
Elmsford 
Bronx 

Farmingdale 
Stony  Point 
East  Syracuse 
Rome 

Ontario 

Poughkeepsie 

Bronx 

Cortland 
Cortland 
New  York 
Long  Island  City 
Long  Island  City 
Johnson  City 


NM 
NM 
NM 


NV 
NV 
NV 


NY 
NY 
NY 
NY 
NY 
NY 
NY 
NY 
NY 
NY 
NY 
NY 
NY 
NY 
NY 
NY 

NY 
NY 
NY 
NY 
NY 
NY 
NY 
NY 
NY 
NY 
NY 
NY 
NY 

NY 
NY 
NY 

NY 
NY 
NY 
NY 
NY 
NY 


PLM 

Dosimetry 
Calibration 


PLM 
PLM 

Dosimetry 


PLM 
PLM 
PLM 
PLM 
PLM 
TEM 
PLM 
PLM 
TEM 
PLM 

Dosimetry 

Commercial 

FCC 

PLM 

TEM 

FCC 

PLM 
TEM 
PLM 
TEM 
PLM 
TEM 
PLM 
TEM 
PLM 
TEM 

Construction 
PLM 

Calibration 

Dosimetry 
Acoustics 
Acoustics 

Lighting 
Thermal  Insl. 
PLM 
PLM 
TEM 

MIL-STD-462 


NVLAP  1999  DIRECTORY  -  Page  C14 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  C.  LISTING  BY  STATE/COUNTRY  -  continued 


LABORATORY  NAME 

NVT  AP 
LAB  CODE 

CITY 

STATF/ 
COUNTRY 

FIELD 

Laboratory 

New  York  Testing  Laboratories,  Inc. 

101332-0 

Bay  Shore 

NY 

PLM 

New  York  Testing  Laboratories,  Inc. 

101332-0 

Bay  Shore 

NY 

TEM 

NGC  Testing  Services,  National  Gypsum 

200291-0 

Buffalo 

NY 

Acoustics 

Research  Center 

Niche  Analysis,  Inc. 

102057-0 

Mount  Vernon 

NY 

PLM 

NY  Environmental  &  Analytical  Labs,  Inc. 

101967-0 

Port  Washington 

NY 

PLM 

O'Brien  &  Gere  Laboratories,  Inc. 

101343-0 

Syracuse 

NY 

PLM 

O'Brien  &  Gere  Laboratories,  Inc. 

101343-0 

Syracuse 

NY 

TEM 

PSI 

101755-0 

New  York 

NY 

PLM 

PSI,  Inc. 

101070-0 

Farmingdale 

NY 

PLM 

Rapid  Environmental  Management,  Inc. 

101974-0 

Great  Neck 

NY 

PLM 

Retlif  Testing  Laboratories 

100267-0 

Ronkonkoma 

NY 

FCC 

Retlif  Testing  Laboratories 

100267-0 

Ronkonkoma 

NY 

MIL-STD. 

Scientific  Laboratories,  Inc. 

101904-1 

New  York 

NY 

PLM 

Scientific  Laboratories,  Inc. 

101904-1 

New  York 

NY 

TEM 

Taylor  Environmental  Group,  Inc. 

102101-0 

Floral  Park 

NY 

PLM 

Testing  Mechanics  Corp. 

102001-0 

Seaford 

NY 

PLM 

Testwell  Laboratories,  Inc./Testwell 

200083-0 

Ossining 

NY 

Construed 

Industries,  Inc. 

Testwell  Laboratories,  Inc./Testwell 

200083-0 

Ossining 

NY 

PLM 

Industries,  Inc. 

Testwell  Laboratories,  Inc./Testwell 

200083-0 

Ossining 

NY 

TEM 

Industries,  Inc. 

Underwriters  Laboratories,  Inc. 

100255-0 

Melville 

NY 

FCC 

Vartest  Laboratories,  Inc. 

200027-0 

New  York 

NY 

Carpet 

WKP  Laboratories,  Inc. 

1 U 1  y  jU-U 

ossining 

IN  I 

PT  M 

OH 

A  T  Labs 

101062-0 

Youngstown 

OH 

PLM 

American  Electric  Power,  Environmental 

102102-0 

Columbus 

OH 

PLM 

Laboratory 

ATC  Associates  Inc. 

102071-0 

Cincinnati 

OH 

PLM 

DataChem  Laboratories 

101917-0 

Cincinnati 

OH 

PLM 

DataChem  Laboratories 

101917-0 

Cincinnati 

OH 

TEM 

DLZ  Laboratories,  Inc. 

101060-0 

Columbus 

OH 

PLM 

EA  Group 

101019-0 

Mentor 

OH 

PLM 

EssTek  Ohio,  Inc. 

102093-0 

Middleburg  Heights 

OH 

PLM 

Fluor  Daniel  Fernald,  Inc.,  Analytical 

102010-0 

Cincinnati 

OH 

PLM 

Laboratory  Services 

GE  Lighting-  Engineering  Support  -  NA 

100398-0 

Cleveland 

OH 

Lighting 

Gelles  Laboratories,  Inc. 

101170-0 

Columbus 

OH 

PLM 

Gelles  Laboratories,  Inc. 

101170-0 

Columbus 

OH 

TEM 

Lockheed  Martin  Utility  Services,  Inc. 

101383-0 

Piketon 

OH 

PLM 

m.a.c.  Paran  Consulting  Services,  Inc. 

102108-0 

Amelia 

OH 

PLM 

NASA-Lewis  Research  Center 

200130-0 

Cleveland 

OH 

PLM 

NOVA  Machine  Products 

200202-0 

Middleburg  Heights 

OH 

Fasteners 

Owens  Corning  Testing  Systems  -  Product 

100109-0 

Granville 

OH 

Acoustics 

Testing  Laboratory 

Owens  Corning  Testing  Systems  -  Product 

100109-0 

Granville 

OH 

Thermal  Ir 

Testing  Laboratory 

TolTest,  Inc. 

101594-0 

Toledo 

OH 

PLM 

Tremco,  Inc.  -  Roofing  Division,  An  RPM 

101188-0 

Beachwood 

OH 

PLM 

NVLAP  1999  DIRECTORY  -  Page  C15 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  C.  LISTING  BY  STATE/COUNTRY  -  continued 


LABORAIORY  NAME 

NVLAP 
LAB  CODE 

CITY 

STATE/ 
COUNTRY 

FIELD 

Company 

Webber  Gage  Division  /  L.S.  Starrett  Co. 

200038-0 

Cleveland 

OH 

Calibration 

OK 

Hollytex  Carpet  Mills,  Inc. 

100247-0 

Anadarko 

OK 

Carpet 

Oklahoma  Dept.  of  Environmental 

102112-0 

Oklahoma  City 

OK 

PLM 

Quality-State  Environmental  Lab 

Precision  Testing  Laboratories,  Inc. 

101580-0 

Moore 

OK 

PLM 

QuanTEM  Laboratories,  LLC 

101959-0 

Oklahoma  City 

OK 

PLM 

QuanTEM  Laboratories,  LLC 

101959-0 

Oklahoma  City 

OK 

TEM 

SGS  U.S.  Testing  Company,  Inc. 

100416-0 

Tulsa 

OK 

Commercial 

SGS  U.S.  Testing  Company,  Inc. 

100416-0 

Tulsa 

OK 

Thermal  Insl. 

TEC-AN,  Inc. 

200325-0 

Oklahoma  City 

OK 

PLM 

OR 

AGRA  Earth  and  Environmental,  Inc.  -  En  v. 

200357-0 

Portland 

OR 

PLM 

Chemistry  Laboratory 

ECS/Wagner  Environmental 

101064-0 

Eugene 

OR 

PLM 

HPNW 

100567-0 

Tigard 

OR 

Dosimetry 

InFocus  Systems,  Inc. 

2001 52-0 

Wilsonville 

OR 

FCC 

Northwest  EMC,  Inc. 

200059-0 

Newberg 

OR 

FCC 

PBS  Environmental  Building  Consultants, 
Inc. 

101910-0 

Portland 

OR 

PLM 

Portland  Bolt  and  Manufacturing  Company, 

200168-0 

Portland 

OR 

Fasteners 

Inc.  Testing  Laboratory 

Professional  Service  Industries,  Inc., 

100430-0 

Eugene 

OR 

Wood  Prod. 

Pittsburgh  Test.  Lab.  Div. 

Timberco,  Inc.-  dba  TECO 

100420-0 

Eugene 

OR 

Wood  Prod. 

Willamette  Industries,  Inc.  West  Coast 

200045-0 

Wilsonville 

OR 

Commercial 

Development  Lab 

PA 

Accredited  Environmental  Technologies,  Inc. 

101051-0 

Media 

PA 

PLM 

AGX,  Inc. 

101578-0 

Cranberry  Township 

PA 

PLM 

Allegheny  Asbestos  Analysis 

101704-0 

Carnegie 

PA 

PLM 

American  Testing  Laboratories,  Inc. 

100146-0 

Lancaster 

PA 

Construction 

Analab,  LLC 

200260-0 

Sterling 

PA 

FCC 

Architectural  Testing  Inc. 

200361-0 

York 

PA 

Acoustics 

Armstrong  Acoustic  Labs,  Armstrong  World 

100228-0 

Lancaster 

PA 

Acoustics 

Ind.,  Inc.  Innov.  Center 

BarTech  Inc.  -  Chemical  Laboratory 

200148-0 

Johnstown 

PA 

Fasteners 

Criterion  Laboratories,  Inc. 

102046-0 

Bensalem 

PA 

PLM 

Dodge-Regupol,  Inc.  Laboratory 

200030-0 

Lancaster 

PA 

Commercial 

Duquesne  Light  Company,  Beaver  Valley 

100521-0 

Shippingport 

PA 

Dosimetry 

Power  Station 

GA  Environmental  Services,  Inc. 

101996-0 

Eddystone 

PA 

PLM 

GPU  Nuclear  Chemistry/Materials  Labs. 

102064-0 

Reading 

PA 

PLM 

GPU  Nuclear  Corp. 

100510-0 

Middletown 

PA 

Dosimetry 

Henry  Troemner,  Inc. 

105013-0 

Philadelphia 

PA 

Calibration 

Instrument  Specialties  Co.,  Inc. 

200076-0 

Delaware  Water  Gap 

PA 

FCC 

Kevco  Services,  Inc. 

101941-0 

Butler 

PA 

PLM 

Levecque  Technical  Center 

100101-0 

Blue  Bell 

PA 

Thermal  Insl. 

Michael  &  Associates 

100427-0 

State  College 

PA 

Acoustics 

NVLAP  1999  DIRECTORY  -  Page  CI 6 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  C.  LISTING  BY  STATE/COUNTRY  -  continued 


LABORATORY  NAME 

1>  V  LAI 

LAB  CODE 

CITY 

CT  A  TV  1 

a  1 A 1  Li/ 
COUNTRY 

FIELD 

Microbac  Laboratories,  Inc. 

101035-0 

Erie 

PA 

PLM 

PA  DEP  Bureau  of  Laboratories 

101323-0 

Harrisburg 

PA 

PLM 

Philip  Analytical  Services 

101262-0 

Reading 

PA 

PLM 

Philip  Analytical  Services 

101262-0 

Reading 

PA 

TEM 

PP&L,  Inc. 

100554-0 

Allentown 

PA 

Dosimetry 

PSI 

101350-0 

Pittsburgh 

PA 

PLM 

PSI 

101350-0 

Pittsburgh 

PA 

TEM 

R  &  B  Enterprises 

100280-0 

West  Conshohocken 

PA 

FCC 

R  &  B  Enterprises 

100280-0 

West  Conshohocken 

PA 

MIL-STD-462 

RJ  Lee  Group,  Inc. 

101208-0 

Monroeville 

PA 

PLM 

RJ  Lee  Group,  Inc. 

101208-0 

Monroeville 

PA 

TEM 

SPS  Technologies;  Aerospace  Fastener  Group  200 164-0 

Jenkintown 

PA 

Fasteners 

The  Perryman  Company 

200128-0 

Houston 

PA 

Fasteners 

Volz  Environmental  Services,  Inc. 

101269-0 

Pittsburgh 

PA 

TIT  IV  A 

PLM 

PR 

A  n          fell  P  Tl\/ir/"\n  frtATl  ta  1  Qpn/ifPC 
/\Ilcuy HCdl  dlvlIUllIIlCIUal  OCIVlcCo 

Hato  Rey 

PR 

PLM 

International,  Inc. 

RI 

FM^I  Analvtioal  Trie 

102105-0 

Warwick 

RI 

PLM 

RI  Analytical  Laboratories,  Inc. 

101440-0 

Warwick 

RI 

PLM 

SNB  Laboratory 

200308-0 

Cumberland 

K 1 

Fasteners 

sc 

Compliance  Test  Laboratories,  Inc. 

200237-0 

Liberty 

SC 

FCC 

Davis  &  Floyd,  Inc. 

101410-0 

Greenwood 

sc 

PLM 

South  Carolina  Department  of  Health  & 

101572-0 

Columbia 

sc 

PLM 

Fn vironmpntal  fontTnl 

TN 

Leland-Powell  Fasteners,  Inc.  Fastener 

200171-0 

Martin 

TN 

Fasteners 

Testing  Laboratory 

MagneTek  (Lexington)  Engineering 

200053-0 

Lexington 

TN 

Electric  Motors 

Laboratory 

National  Econ  Corporation 

200047-0 

Memphis 

TN 

PLM 

Oak  Ridge  Metrology  Center 

105000-0 

Oak  Ridge 

TN 

Calibration 

Oak  Ridge  National  Laboratory 

200228-0 

Oak  Ridge 

TN 

PLM 

Oak  Ridge  National  Laboratory  Electric 

200244-0 

Oak  Ridge 

TN 

Electric  Motors 

Machinery  Center 

R&D  Services,  Inc. 

200265-0 

Cookeville 

TN 

Thermal  Insl. 

Tennessee  Valley  Authority  External 

100516-0 

Soddy-Daisy 

TN 

Dosimetry 

Dosimetry  Service 

TX 

A  &  B  Environmental  Services,  Inc. 

101793-0 

Houston 

TX 

PLM 

Acoustic  Systems  Acoustical  Research 

100286-0 

Austin 

TX 

Acoustics 

Facility 

ATC  Associates  Inc. 

200290-0 

Dallas 

TX 

PLM 

Atomic  Energy  Industrial  Laboratory  of  the 

100556-0 

Houston 

TX 

Dosimetry 

Southwest,  Inc. 

Austin  Analytical  Laboratory 

200014-0 

Austin 

TX 

PLM 

CAM  Environmental  Services,  Inc. 

200240-0 

Pasadena 

TX 

PLM 

NVLAP  1999  DIRECTORY  -  Page  CI 7 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  C.  LISTING  BY  STATE/COUNTRY  -  continued 


LABORATORY  NAME 


NVLAP 

LAB  CODE  CITY 


STATE/ 
COUNTRY 


FIELD 


CHEMTEX  Environmental  Laboratory,  Inc.  200025-0 
Compaq  Computer  Corp.  Emissions  Control  200058-0 
Lab 

Compaq  Corporate  Metrology  200154-0 

Crisp  Analytical  Laboratory  200349-0 

Crisp  Analytical  Laboratory  200349-0 

Dell  Regulatory  Test  Laboratories  200052-0 

Dell  Regulatory  Test  Laboratories  200052-0 

Dolphin  Environmental  Consultants  102086-0 

EcoSystems  Environmental,  Inc.  1011 62-0 

EMSL  Analytical,  Inc.  1 02 1 06-0 

EMSL  Analytical,  Inc.  1 02 1 06-0 

EMSL  Analytical,  Inc.  200034-0 

EMSL  Analytical,  Inc.  200034-0 

Envirotest,  Inc.  101595-0 

ERI  Consulting  Engineers,  Inc.  101232-0 

HIH  Laboratory,  Inc.  1 0 1 233-0 

IBM  Austin  EMC  200112-0 

Jimmie  Ann  Bolton  101735-0 

KTL  Dallas,  Inc.  100426-0 

LambdaMetrics,  Inc.  200122-0 

Law  Engineering  and  Environmental  101152-0 
Services,  Inc. 

Law  Engineering  and  Environmental  101973-0 
Services,  Inc. 

Loflin  Environmental  Services  102044-0 

Maxim  Technologies,  Inc.  101091-0 

Maxim  Technologies,  Inc.  1 0 1 09 1  -0 

Maxim  Technologies,  Inc.  1 0 1 09 1  - 1 

McKee  Environmental  Health,  Inc.  1 0 1 135-0 

Metroplex  Metrology  Lab,  Inc.  200262-0 

Micro  Air  of  Texas,  Inc.  1 02008-0 

Omni  Environmental,  Inc.  102061-0 

Professional  Testing  (EMI),  Inc.  200062-0 

Quest  MicroAnalytics,  Inc.  200249-0 

Reservoirs  Environmental  Services,  Inc.  1 0 1 896- 1 

Reservoirs  Environmental  Services,  Inc.  101896-1 

RheinTexas,  Inc.  200245-0 

RJ  Lee  Group,  Inc.  101208-5 

RJ  Lee  Group,  Inc.  101208-5 
South  Texas  Project  Dosimetry  Laboratory     1 005 1 9-0 

Steve  Moody  Micro  Services,  Inc.  102056-0 

Steve  Moody  Micro  Services,  Inc.  1 02056-0 

Sun  City  Analytical,  Inc.  101870-0 

Toshiba/Houston  Test  Laboratory  200088-0 
TU  Electric-Comanche  Peak  Steam  Electric  1 00528-0 
Station 

US  Air  Force  Center  for  Radiation  Dosimetry  100548-0 

Walker  Bolt  Manufacturing  Co.  200 1 26-0 
Water,  Earth  Solutions  &  Technologies,  Inc.   1 02043-0 

Wayne  Langston,  Inc.  20002 1  -0 


Port  Arthur 
Houston 

Houston 

Carrol  lton 

Carrollton 

Round  Rock 

Round  Rock 

Stafford 

Carrollton 

Houston 

Houston 

Dallas 

Dallas 

Houston 

Tyler 

Webster 

Austin 

Austin 

Lewisville 

Cedar  Park 

Houston 

Dallas 

Houston 

Dallas 

Dallas 

Houston 

Friendswood 

Fort  Worth 

Houston 

Austin 

Round  Rock 

Dallas 

Houston 

Houston 

Piano 

Houston 

Houston 

Wadsworth 

Carrollton 

Carrollton 

El  Paso 

Houston 

Glen  Rose 

Brooks  AFB 
Houston 
Dallas 
League  City 


TX 
TX 

TX 
TX 
TX 
TX 
TX 
TX 
TX 
TX 
TX 
TX 
TX 
TX 
TX 
TX 
TX 
TX 
TX 
TX 
TX 

TX 

TX 
TX 
TX 
TX 
TX 
TX 
TX 
I  X 
TX 
TX 
TX 
TX 
TX 
TX 
TX 
TX 
TX 
TX 
TX 
TX 
TX 

TX 
TX 
TX 
TX 


PLM 

FCC 

Calibration 

PLM 

TEM 

Acoustics 

FCC 

PLM 

PLM 

PLM 

TEM 

PLM 

TEM 

PLM 

PLM 

PLM 

FCC 

PLM 

FCC 

FCC 

PLM 

PLM 

PLM 
PLM 
TEM 
PLM 
PLM 

Calibration 

PLM 

PLM 

FCC 

PLM 

PLM 

TEM 

FCC 

PLM 

TEM 

Dosimetry 
PLM 
TEM 
PLM 

Electric  Motors 
Dosimetry 

Dosimetry 
Fasteners 
PLM 
FCC 


NVLAP  1999  DIRECTORY  -  Page  C18 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  C.  LISTING  BY  STATE/COUNTRY  -  continued 


NVLAP  STATE/ 
LABORATORY  NAME  LAB  CODE  CITY  COUNTRY  FIELD 

UT 


Communication  Certification  Laboratory 

100272-0 

Salt  Lake  City 

UT 

FCC 

Dixon  Information  Inc. 

101012-0 

South  Salt  Lake 

UT 

PLM 

VA 

Alloy  &  Stainless  Testing 

200353-0 

Virginia  Beach 

VA 

Fasteners 

American  Medical  Laboratories,  Inc. 

101136-0 

Chantilly 

VA 

PLM 

Applied  Environmental,  Inc. 

101611-0 

Reston 

VA 

PLM 

Cryptographic  Equipment  Assessment  Lab. 

200002-0 

McLean 

VA 

Cryptograpl 

(CEAL) 

EMSL  Analytical,  Inc. 

101277-0 

Fairfax 

VA 

PLM 

EMSL  Analytical,  Inc. 

101277-0 

Fairfax 

VA 

TEM 

Environmental  Hazards  Services,  L.L.C. 

101882-0 

Richmond 

VA 

PLM 

Environmental  Testing  and  Monitoring 

200131-0 

Virginia  Beach 

VA 

PLM 

Services,  Inc. 

Froehling  &  Robertson,  Inc. 

102060-0 

Richmond 

VA 

PLM 

Hubbell  Lighting  Photometric  Laboratory 

200020-0 

Christiansburg 

VA 

Lighting 

Industrial  Laboratory 

102115-0 

Portsmouth 

VA 

PLM 

Labcorp  Analytics  Laboratory 

101004-0 

Richmond 

VA 

PLM 

Law  Engineering  and  Environmental 

101847-0 

Sterling 

VA 

PLM 

Services,  Inc. 

Marine  Chemist  Service,  Inc. 

101425-0 

Newport  News 

VA 

PLM 

Newport  News  Shipbuilding  Radiological 

100561-0 

Newport  News 

VA 

Dosimetry 

Control  Department 

Pacific  Environmental  Services,  Inc. 

101190-0 

Herndon 

VA 

PLM 

Proxtronics,  Inc. 

100573-0 

Burke 

VA 

Dosimetry 

Rhein  Tech  Laboratories,  Inc. 

200061-0 

Herndon 

VA 

FCC 

RJ  Lee  Group,  Inc. 

101208-3 

Manassas 

VA 

PLM 

RJ  Lee  Group,  Inc. 

101208-3 

Manassas 

VA 

TEM 

Schneider  Laboratories,  Inc. 

101150-0 

Richmond 

VA 

PLM 

Scientific  Laboratories,  Inc. 

101904-0 

Midlothian 

VA 

PLM 

Scientific  Laboratories,  Inc. 

101904-0 

Midlothian 

VA 

TEM 

ocA5,  inc. 

i ai i oc  n 

OlaCKSDUrg 

VA 
v  /\ 

PI  M 

State  of  Virginia  Metrology  Lab 

105007-0 

Richmond 

VA 

Calibration 

TC  Analytics,  Inc. 

101672-0 

Norfolk 

VA 

PLM 

VT 

Vermont  Fasteners  Manufacturing 

200254-0 

Swanton 

VT 

Fasteners 

WA 

APA  -  The  Engineered  Wood  Association 

100423-0 

Tacoma 

WA 

Wood  Prod. 

Research  Center 

Battelle  -  Pacific  Northwest  National 

200216-0 

Richland 

WA 

Dosimetry 

Laboratory 

BCAG  Fastener  Quality  Test  Lab  Everett  Site  200292-0 

Seattle 

WA 

1  asteners 

Clayton  Environmental  Consultants 

101106-0 

Seattle 

WA 

PLM 

EMSL  Analytical,  Inc. 

200019-0 

Seattle 

WA 

PLM 

EMSL  Analytical,  Inc. 

200019-0 

Seattle 

WA 

TEM 

Fluke  Corporation  Primary  Standards 

105016-0 

Everett 

WA 

Calibration 

Laboratory 

Key  Tronic  Corp. 

200096-0 

Spokane 

WA 

FCC 

Lab/Cor,  Inc. 

101920-0 

Seattle 

WA 

TEM 

NVLAP  1999  DIRECTORY  -  Page  C19 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  C.  LISTING  BY  STATE/COUNTRY  -  continued 


LABORATORY  NAME 

NVLAP 
LAB  CODE 

CITY 

STATE/ 
COUNTRY 

FIELD 

Mountain  Laboratories 

101890-0 

Spokane 

WA 

PLM 

Naval  Nuclear  Propulsion  Program 

100565-0 

Bremerton 

WA 

Dosimetry 

Directorate,  Washington,  D.C. 

Northwest  Envirocon,  Inc. 

101869-0 

Vancouver 

WA 

PLM 

NVL  Laboratories,  Inc. 

102063-0 

Seattle 

WA 

PLM 

Pacific  Northwest  National  Laboratory 

105020-0 

Richland 

WA 

Calibration 

Pacific  Rim  Environmental,  Inc. 

101631-0 

Tukwila 

WA 

PLM 

Prezant  Associates,  Inc. 

101886-0 

Seattle 

WA 

PLM 

Puget  Sound  Naval  Shipyard 

101539-0 

Bremerton 

WA 

PLM 

Safe  Environment  of  America 

102021-0 

Kent 

WA 

PLM 

Underwriters  Laboratories  Inc. 

200214-0 

Camas 

WA 

FCC 

United  States  Dosimetry  Technology,  Inc. 

100571-0 

Richland 

WA 

Dosimetry 

Waste  Management  Federal  Services  of 

101058-0 

Richland 

WA 

PLM 

Hanford,  Inc. 

WI 

AIResearch,  Inc. 

101868-0 

Wauwatosa 

WI 

PLM 

Aurora  Consolidated  Laboratories 

101661-0 

West  Allis 

Wl 

PLM 

Hufcor  Laboratory 

100239-0 

Janesville 

WI 

Acoustics 

Intertek  Testing  Services  NA  Inc. 

200031-0 

Middleton 

WI 

Thermal  Insl. 

Marathon  Electric  -  Wausau  Engineering  Lab.  200 134-0 

Wausau 

WI 

Electric  Motors 

Micro  Analytical,  Inc. 

101247-0 

Milwaukee 

WI 

PLM 

PFS  Corporation 

100421-0 

Madison 

WI 

Wood  Prod. 

PSI,  Inc. 

200042-0 

New  Berlin 

WI 

PLM 

Rice  Lake  Weighing  Systems 

105001-0 

Rice  Lake 

WI 

Calibration 

Wausau  Insurance  Companies 

101079-0 

Wausau 

WI 

PLM 

Wisconsin  Occupational  Health  Laboratory 

101109-0 

Madison 

WI 

PLM 

wv 

Environmental  Services  International,  Inc. 

101306-0 

St.  Albans 

wv 

PLM 

Philips  Lighting  Corporate  Calibration  & 

100399-0 

Fairmont 

wv 

Lighting 

Standards  Laboratory 

Triad  Environmental  Consulting,  Inc. 

102073-0 

Huntington 

wv 

PLM 

BRAZIL 

Acominas  -  Analysis  and  Testing  Laboratory 

200185-0 

Ouro  Branco  MG 

BRAZIL 

Fasteners 

Belgo-Mineira  Chemical  Laboratory 

200196-0 

35.930-900  Joao  Monlevade 

BRAZIL 

Fasteners 

CANADA 

Canadian  Standards  Association 

100322-0 

Etobicoke  Ontario 

CANADA 

Commercial 

Canadian  Standards  Association 

100322-0 

Etobicoke  Ontario 

CANADA 

FCC 

Celestica  International  Inc. 

200055-0 

North  York,  Ontario 

CANADA 

FCC 

Chatfield  Technical  Consulting  Limited 

101103-0 

Mississauga  Ontario 

CANADA 

PLM 

DOMUS  ITSL,  a  division  of  LGS  Group, 

200017-0 

Ottawa  Ontario 

CANADA 

Cryptographic 

Incorporated 

Electronics  Test  Centre 

200282-0 

Kanata,  Ont. 

CANADA 

FCC 

Ingersoll  Fasteners 

200208-0 

Ingersoll  Ontario 

CANADA 

Fasteners 

Ivaco  Rolling  Mills,  Chemistry  Laboratory 

200143-0 

L'Orignal  Ontario 

CANADA 

Fasteners 

KTL  Ottawa  Inc. 

100351-0 

Ottawa  Ontario 

CANADA 

FCC 

Northern  Telecom  BVW  Lab 

200098-0 

Belleville,  Ontario 

CANADA 

FCC 

Northern  Telecom  Product  Integrity  Labs. 

100350-0 

Kanata  Ontario 

CANADA 

FCC 

Pinchin  Environmental  Ltd. 

101270-0 

Mississauga  Ontario 

CANADA 

PLM 

Small  IAC  Test  Laboratory 

200287-0 

Peterborough 

CANADA 

Electric  Motors 

NVLAP  1999  DIRECTORY  -  Page  C20 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  C.  LISTING  BY  STATE/COUNTRY  -  continued 

NVLAP  STATE/ 


v  yj un  i  iv  i 

FTFI  D 

UltraTech  Engineering  Labs  Inc. 

200093-0 

Mississauga,  Ontario 

CANADA 

FCC 

Vibro-Acoustics  Laboratory 

100424-0 

Scarborough  Ontario 

CANADA 

Acoustics 

INDIA 

Sundram  Fasteners  Limited  (Inhouse  test 

200212-0 

Chennai  (Madras),  Tamil 

INDIA 

Fasteners 

laboratory) 

Sundram  Fasteners  Limited  Chemical  Testing 

200256-0 

Andhra  Pradesh 

INDIA 

Fasteners 

Laboratory 

JAPAN 

A-Pex  International  Co.,  Ltd.  Yokowa 

200109-0 

Mie-ken 

JAPAN 

FCC 

Laboratory 

Akzo  Kashima  Ltd.  Kakegawa  EMC  Test  Site  100290-2 

Shizuoka 

JAPAN 

FCC 

Akzo  Kashima  Ltd.,  Kashima  EMC  Site 

100290-0 

Ibaraki 

JAPAN 

FCC 

Akzo  Kashima  Ltd.,  Kawasaki  Technical 

200300-0 

Kawasaki 

JAPAN 

FCC 

Center 

Akzo  Kashima  Ltd.,  Matsuda  EMC  lest  Site 

100290-4 

Kanagawa 

JAPAN 

FCC 

Akzo  Kashima  Ltd.,  Nagano  EMC  1  est  Site 

100290-3 

Nagano 

JAPAN 

FCC 

Akzo  Kashima  Ltd.,  Tochigi  EMC  Test  Site 

i  rtmoA  c 
IvUZyO-D 

Tochigi 

JAPAN 

FCC 

Aoyama  Fastener  Laboratory 

200213-0 

Niwa-gun,  Aichi  Prefecture 

JAPAN 

Fasteners 

Asakawa  Screw  Co.,  Ltd. 

1  A  A  1  A-?  A 

200197-0 

Yokohama 

JAPAN 

Fasteners 

Asakawa  Screw  Co.,  Ltd.  Kawawa  Factory 

2002:3  /-0 

Yokohama 

JAPAN 

Fasteners 

Chemitox  EMC  Research,  Inc. 

■"l  A  A  1  O  A  A 

200120-0 

Yamanashi-ken 

JAPAN 

FCC 

Cosmos  Corporation 

OA A 1 C 1  A 

200 1 5 1-0 

Watarai-gun  Mie 

JAPAN 

FCC 

Electro.  Meas.  Oil.,  Yokohama  Res.  &  Dev. 

20026J-0 

Kanagawa 

JAPAN 

FCC 

Ctr.  Murata  Mfg.  Co. 

EMC  Kashima  Corporation 

OAAA*7A  A 

2000  /0-0 

Chiba-ken 

JAPAN 

FCC 

Fuji  Buhin  Kogyo  Kabushiki  Kaisha 

OAAOA1  A 

20020j-0 

Ohta  Gunma 

JAPAN 

Fasteners 

Fujitsu  Evaluation  Engineering  Laboratory 

20028 I-O 

Numazu,  Shizuoka-Pref. 

JAPAN 

FCC 

Fujitsu  General  EMC  Laboratory 

OAA1  H~)  A 

200373-0 

Kawasaki 

JAPAN 

FCC 

ruserasm  Gunma 

ZOO  1  /j-U 

Gunma-Ken 

JAPAN 

Fasteners 

XT'*         1*T      f                  i  '             rp        i             -J  /— ^  Til 

Hitachi  Information  Technology  Co.,  Ltd. 

O  A  A  1  D  f  A 

200 l 86-0 

Kanagawa 

JAPAN 

FCC 

Nakai  Test  Site 

IBM  Yamato  EMC  Engineering 

200 l 98-0 

Yamato  Kanagawa 

JAPAN 

FCC 

IPS  Corporation 

O  A  A  A  1  O  A 

200012-0 

Nagano 

JAPAN 

FCC 

Japan  Quality  Assurance  Org.  Chubu  Testing 

200190-0 

Aichi 

JAPAN 

FCC 

Center  Shikatsu  Branch 

Japan  Quality  Assurance  Org.  Safety  Testing 

200192-0 

Yamanashi 

JAPAN 

FCC 

Ctr.  Tsuru  EMC  Branch 

Japan  Quality  Assurance  Organization 

200191-0 

Osaka 

JAPAN 

FCC 

Kita-Kansai  Testing  Center 

Japan  Quality  Assurance  Organization  Safety 

200189-0 

Tokyo 

JAPAN 

FCC 

Testing  Center 

Kansai  Electronic  Industry  Development 

200207-0 

Ikoma  Nara 

JAPAN 

FCC 

Center,  Ikoma  Testing  Lab. 

Kobelco  Research  Institute,  Inc.  Stock 

200169-0 

Kobe 

JAPAN 

Fasteners 

Company 

Kyowa  Kogyosyo  Co.,  Ltd.  Test  Laboratory 

200274-0 

Komatsu  City,  Ishikawa 

JAPAN 

Fasteners 

Matsushita  EMC  Center 

100428-0 

Taki-gun,  Hyogo 

JAPAN 

FCC 

Meidoh  Laboratory 

200239-0 

Toyota,  Aichi 

JAPAN 

Fasteners 

Metallic  Material  Laboratory  in  Toyota 

200223-0 

1  Uyuid  Lily  /\lwU 

JAPAN 

Pa  Qfpn  pre 

Motor  Co. 

Minebea  Co.,  Ltd.  Fujisawa  Manufacturing 

200229-0 

Fujisawa,  Kanagawa 

JAPAN 

Fasteners 

NVLAP  1999  DIRECTORY  -  Page  C21 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  C.  LISTING  BY  STATE/COUNTRY  -  continued 


LABORATORY  NAME 

NVLAP 
LAB  CODE 

STATE/ 

LUU1>  1  K  i 

¥  UE  ILLP 

Unit 

0  &  K  Company  Limited,  Osaka  Test  Center  200166-0 

Osaka-Shi 

JAPAN 

Fasteners 

Ohtama  Co.,  Ltd.  Yamanashi  EMC  Test  Site 

200175-0 

Yamanashi 

T  A  T"»  A  X  T 

JAPAN 

FCC 

Okai  Iron  Works  Co.,  Ltd. 

200299-0 

Izumisano  Osaka 

JAPAN 

Fasteners 

Okawa  Laboratory 

200296-0 

Naka-gun,  Ibaraki-ken 

JAPAN 

Fasteners 

Owari  Precise  Products  Co.,  Ltd. 

200227-0 

Nagoya 

JAPAN 

Fasteners 

PFU  TECHNOCONSUL  EMC  Center 

200259-0 

Ishikawa-Ken 

JAPAN 

FCC 

Ricoh  Company  LTD.  Ohmori  Acoustics  Test  200345-0 

Tokyo 

JAPAN 

Acoustics 

Site 

Ricoh  Company,  Ltd.  Ohmori  EMC  Center 

200163-0 

Tokyo 

JAPAN 

FCC 

Sannohashi  Corporation 

200205-0 

Yashioshi,  Saitama-ken 

JAPAN 

Fasteners 

Seiko  Epson  Corporation 

200157-0 

Shiojiri-City  Nagano 

JAPAN 

FCC 

Sony  Atsugi  EMC  Site 

200285-0 

Shinagawa,  Tokyo 

JAPAN 

FCC 

Sony  Minokamo  EMC  Site 

200368-0 

uitu-rrei. 

I  A  D  A  XT 

JArAN 

r  LL 

Sugiura  Seisakusho  Co.,  Ltd. 

200226-0 

Nishio  Aichi 

JAPAN 

Fasteners 

Sumitomo  Metal  Technology,  Inc.  Kokura 

200215-0 

Kitakyushu 

JAPAN 

Fasteners 

Division 

TDK  Corporation's  10m  Anechoic  Chamber 

200309-0 

Ichikawa-shi,  Chiba-ken 

JAPAN 

FCC 

and  Chikumagawa  Open  Site 

TDK  Corporation's  Chikumagawa  Open  Site 

200319-0 

Saku-shi,  Nagano-ken 

JAPAN 

FCC 

TEAC  Corporation  EMC  Center 

200362-0 

Iruma-shi 

JAPAN 

FCC 

Tokin  EMC  Engineering  Co.,  Ltd.  Kawasaki 

200217-0 

Kawasaki-city,  Kanagawa 

JAPAN 

FCC 

Facility 

Tokin  EMC  Engineering  Co.,  Ltd.  Nagoya 

200219-0 

Daian-cho,  Inabe-gun,  Mie 

I  A  r»  A  X  I 

JAPAN 

FCC 

Testing  Laboratory 

Tokin  EMC  Engineering  Co.,  Ltd.  Osaka 

200218-0 

Sanda-city,  Hyogo 

JAPAN 

FCC 

Testing  Laboratory 

Tokin  EMC  Engineering  Co.,  Ltd.  Tsukuba 

ZvOZZ 1-U 

Tsukuba-city,  Ibaraki 

JAPAN 

FCC 

Testing  Laboratory 

Topura  Co.,  Ltd. 

-inn  1  O  1  A 

ZUU 1 O 1 -U 

Hadano  Kanagawa 

JAPAN 

Fasteners 

Topura  Co.,  Ltd.  Osaka 

Z<JvZ4Z-\) 

Katano,  Osaka 

JAPAN 

Fasteners 

Topura  Co.,  Ltd.  Tokai 

200243-0 

Ogasagun,Shizuoka 

JAPAN 

Fasteners 

Toshiba  Corp.,  Ome  Works 

200107-0 

Ome  Tokyo 

JAPAN 

FCC 

Yamaha  Motor  Metal  Testing  Laboratory 

200276-0 

Iwata  Shizuoka 

JAPAN 

1  asteners 

Fasteners  and  Metals 

Zacta  Technology  Corporation  Yonezawa 

200306-0 

Yonezawa-shi  Yamagata 

JAPAN 

FCC 

Testing  Center 

KOREA 

Korea  Testing  &  Research  Inst,  for  Chemical 

200177-0 

Inchon 

KOREA 

Fasteners 

Industry-Inchon  Off. 

Korea  Tokin  EMC  Engineering  Co.,  Ltd. 

200220-0 

Namyangju-si,  Kyunggi-Do 

KOREA 

FCC 

LG  Electronics,  Inc.,  Quality  and  Reliability 

200040-0 

Seoul 

KOREA 

FCC 

Center 

MEXICO 

Prottsa,  S.A.  de  C.V. 

200261-0 

Mexico  City 

MEXICO 

Fasteners 

TAIWAN 

Advance  Data  Technology  Corporation 

200102-0 

Taipei  Hsien 

TAIWAN 

FCC 

Electronic  Research  &  Service 

200118-0 

Hsinchu 

TAIWAN 

FCC 

Organ  ization/ITRI 

Electronics  Testing  Center,  Taiwan 

200133-0 

Taoyuan  Hsien 

TAIWAN 

FCC 

NVLAP  1999  DIRECTORY  -  Page  C22 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  C.  LISTING  BY  STATE/COUNTRY  -  continued 


LABORATORY  NAME 


NVLAP 
LAB  CODE 

CITY 

STATE/ 
COUNTRY 

FIELD 

200288-0 

Kaohsiung  Hsien 

TAIWAN 

Fasteners 

200286-0 

Tainan  Hsien 

TAIWAN 

Fasteners 

200085-0 

Taipei  County 

TAIWAN 

FCC 

200331-0 

Taipei  Shien 

TAIWAN 

FCC 

200234-0 

Hsichih  Chen,  Taipei 

TAIWAN 

FCC 

200145-0 

Taipei 

TAIWAN 

FCC 

200097-0 

I  aipei  Hsien 

T  A  FUJ  A  XT 

TAIWAN 

hCC 

200137-0 

Chungli,  Taoyuan 

TAIWAN 

FCC 

200347-0 

Hsin-Chu  City 

TAIWAN 

FCC 

100562-0 

Shihmen,  Taipei 

TAIWAN 

Dosimetry 

200158-0 

Tainan 

TAIWAN 

Fasteners 

200099-0 

Chung-Li,  Taoyuan 

TAIWAN 

FCC 

200079-0 

Taipei  Hsien 

TAIWAN 

FCC 

200280-0 

Kaohsiung,  Kangshan 

TAIWAN 

Fasteners 

200077-0 

Taipei 

TAIWAN 

FCC 

200140-0 

Taoyuan 

TAIWAN 

FCC 

200174-0 

Taipei 

TAIWAN 

FCC 

200304-0 

Kent 

U.  K. 

MIL-STD-462 

100357-0 

Manchester 

U.  K. 

GOSIP 

Fong  Prean  Industrial  Co.,  Ltd. 

Fwu  Kuang  Enterprises  Co.,  Ltd. 

Global  EMC  Standard  Tech.  Corp. 

HomeTek  Technology  Inc. 

International  Standards  Laboratory 

Neutron  Engineering  Inc. 

PEP  Testing  Laboratory 

Philips  Electronics  Industries  (TAIWAN) 

Ltd. 

Quietek  Corporation 

Radiation  Laboratory,  Taiwan  Power 

Company 

San  Shing  Hardware  Works  Co.,  Ltd.  Test 
Laboratory 

Spectrum  Research  &  Testing  Laboratory, 
Inc. 

Sporton  International,  Inc. 

Super  Cheng  Industrial  Testing  Laboratory 

Taiwan  Tokin  EMC  Eng.  Corp. 

TAO/TA2  EMC  Laboratory 

Training  Research  Co.,  Ltd. 

UNITED  KINGDOM 

GEC  Marconi  Avionics  Ltd  Environmental 
and  EMC  Test  Center 
National  Computing  Centre  Ltd. 


NVLAP  1999  DIRECTORY  -  Page  C23 


(See  'How  To  Use  This  Directory'  on  page  7.) 


i 


I! 


11 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE 


NVLAP  LAB  CODE  100101-0 
Levecque  Technical  Center 

1400  Union  Meeting  Road 
P.O.  Box  1100 
Blue  Bell,  PA  19422-0761 
Contact:  Mr.  Peter  Herault 
Phone:  610-341-6376 
Fax: 610-341-6291 

E-Mail:  pete.herault@CT.SGCNA.com 

Thermal  Insulation  Materials 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

Canadian  Standards  (Specifications) 

01/W01  CAN/CGSB-51.2-M88 

01AV03      CAN/CGSB-5 1.1 0-92 

01AV04      CAN/CGSB-5 1.1 1-92 

01AVNOT  Scope  excludes  CGSB  5 1 -GP-52M;  however, 
ASTM  E96  &  ASTM  D828  are  included 
where  specified  in  the  Canadian  Standards 
(01AV02-W04) 

Corrosiveness 

01/C02       16  CFR-Part  1209.5 
Flammability 

01/F01  TAPPIT461-OM 

01/F05       ASTM  El 36 

01/F07       16  CFR-Part  1209.6 

01/F08       16  CFR-Part  1209.7 

Mass,  Density,  and  Dimensional  Stability 

01/D01       ASTM  CI 36 

01/D02       ASTM  CI 67 

01/D08       ASTM  C302 

01/D09       ASTM  C303 

01/D11  ASTMC356 

01/D12  ASTMC411 

01/D24       ASTM  C739  (Sec.  12) 

01/D26       16  CFR-Part  1209.4 

01/D27       ASTM  C739  (Sec.  8) 

01/D3 1       MIL-I-22344D  (Para.  4.6.3,  4.6.4.) 

Related  Material  Properties 

01/V04       ASTM  E96 

01/V07  ASTMC1104/C1104M 

Strength 

01/S01b      ASTM  C165  (Proc.  B  only) 

01/S08       ASTM  C446 

01/S10  ASTMD828 

01/S15  ASTMC421 

01/S16  ASTMC1101/C1101M 

Thermal  Resistance 

01/T01       ASTM  CI 77 

01/T04       ASTM  C236 

01/T05       ASTM  C335 

01/T06       ASTM  C5 18 

01/T09  ASTMC653 

01/T10  ASTMC687 


NVLAP  LAB  CODE  100103-0 
Dow  Chemical  N.  America  Foam  Products 
Research,  Prod.  Perf.  Lab. 

1605  Joseph  Drive 
Midland,  MI  48674 
Contact:  Ms.  Linda  Hess 
Phone:  517-636-5069 
Fax:  517-636-0194 
E-Mail:  lindahess@dow.com 

Thermal  Insulation  Materials 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

Mass,  Density,  and  Dimensional  Stability 

01/D07       ASTM  C272 
01/D18       ASTM  D1622 
01/D19       ASTM  D2126 
01/D23       ASTM  D2842 
Related  Material  Properties 
01/V04       ASTM  E96 
Strength 

01/S02       ASTM  C203 

01/S07       ASTM  C273 

01/S1 1       ASTM  D1621  (Proc.  A) 

Thermal  Resistance 

01/T06       ASTM  C5 18 

NVLAP  LAB  CODE  100104-0 
NAHB  Research  Center,  Inc. 

400  Prince  George's  Boulevard 

Upper  Marlboro,  MD  20774-8731 

Contact:  Mr.  Thomas  M.  Kenney,  P.E. 

Phone:  301-249-4000 

Fax: 301-218-8827 

E-Mail:  tkenney@nahbrc.org 

URL:  http://www.nahbrc.org 

Commercial  Products  Testing 

Accreditation  Valid  Through:  December  31,  1999 


NVLAP 

Code 

Designation 

Paints  and  Related  Coatings  and  Materials 

09/A20 

ASTM  D2244 

Plastics 

15/A18 

ASTM  D2565 

15/A19 

ASTM  D2583 

Plumbing 

19/M01 

ANSI/CABO  A117.1  (Sec.  4.24) 

19/M02 

ASME/ANSI  Al  12.19.7M  (Sec.  5,  7) 

19/M03 

ASME/ANSI  Al  12.19.8M  (Sec.  4,  5) 

19/M04 

ASTM  F446 

19/P01 

ANSIZ124.1  (Sec.  4,  5,6) 

19/P02 

ANSIZ124.2  (Sec.  4,5,6) 

19/P03 

ANSIZ124.3  (Sec.  4,5,6) 

19/P04 

ANSIZ124.4  (Sec.  4,5) 

19/P05 

ANSI  Z124.4  (Sec.  8)  per  ASME  Al  12.19.6M 

(Sec.  7.1) 

19/P06 

ANSI/IAPMO  Z124.6  (Sec.  4,  5,  6) 

NVLAP  1999  DIRECTORY  -  Page  D3 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


19/P07  ANSI/IAPMO  Z124.8  (Sec.  4,  5) 

19/V01  ASME  Al  12.19.2M  (Sec.  7.1) 

19/V02  ASME  Al  12.19. 2M  (Sec.  7.2) 

19/V03  ASME  Al  12.19. 2M  (Sec.  7.3) 

19/V04  ASME  A112.19.2M  (Sec.  7.4) 

19/V06  ASME  Al  12.19.2M  (Sec.  7.7) 

19/W01  ASME  Al  12.19.6  (Sec.  7.1.2) 

19/W02  ASME  Al  12.19.6  (Sec.  7.1.3) 

19/W03  ASME  All  2. 19. 6  (Sec.  7.1.4) 

19/W04  ASME  Al  12. 19.6  (Sec.  7.1.5) 

19/W05  ASME  Al  12.19.6  (Sec.  7.1.6) 

19/W06  ASME  Al  12.19.6  (Sec.  7.1.7) 

19/W07  ASME  Al  12. 19.6  (Sec.  7.1.8) 

19/W08  ASME  Al  12.19.6  (Sec.  7.1.9) 
Thermal  Insulation  Materials 
Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

Mass,  Density,  and  Dimensional  Stability 

01/D02  ASTMC167 
01/D13  ASTMC519 
01/D27  ASTM  C739  (Sec.  8) 
Thermal  Resistance 
01/T06  ASTM  C5 18 
01/T09  ASTM  C6 5 3 
01/T10  ASTMC687 

NVLAP  L  UBCODE  100108-0 
TSi,  Testing  Services,  Inc. 

8 1 7  Showalter  Avenue 

P.O.  Box  2041 

Dalton,GA  30721 

Contact:  Mr.  Erie  W.  Miles,  Jr. 

Phone:  706-226-1400 

Fax:  706-226-6118 

URL:  http://wvAV.testingl-2-3.com 

Carpet  and  Carpet  Cushion 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

Tests  Applicable  to  Carpet  and  Carpet  Cushion 

03/T01       AATCC  16  (Option  E) 

03/T02       ASTM  D2646  (Sees.  16-24) 

03/T04        16CFRPart  1630  (FF- 1-70) 

Tests  Applicable  to  Carpets 

03/G01       AATCC  20 

03/G02       AATCC  20A 

03/G03       AATCC  134 

03/G04       AATCC  165 

03/G05       ASTM  D4 18  (Sec.  8) 

03/G06       ASTM  D4 18  (Sec.  9) 

03/G07       ASTM  D4 18  (Sees.  10-11) 

03/G08       ASTM  D418  (Sec.  13) 

03/G09       ASTM  D1335 

03/G10       ASTM  D3936 

03/G11       ASTM  D5252 

03/G12  ASTME648 

03/G13  ASTME662 

03/G 1 4       Fed  Spec,  DDD-C-0095  A 


NVLAP  LAB  CODE  100109-0 
Owens  Corning  Testing  Systems  -  Product  Testing 
Laboratory 

2790  Columbus  Road,  Route  16 
Granville,  OH  43023-1200 
Contact:  Mr.  J.  Michael  Stair 
Phone:  740-321-7053 
Fax:  740-321-4080 

E-Mail:  mike.stair@owenscorning.com 

Acoustical  Testing  Services 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

08/P03       ASTM  C423  (ISO  354) 
08/P04       ASTM  C522 
08/P35       ASTM  El 050 
Thermal  Insulation  Materials 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 
Corrosiveness 

0 1  /CO  1       ASTM  C739  (Sec.  9) 

Flammability 

01/F02  ASTME84 

01/F05       ASTM  El 36 

01/F07       16  CFR-Part  1209.6 

01/F08        16  CFR-Part  1209.7 

Mass,  Density,  and  Dimensional  Stability 

01/D02  ASTMC167 

01/D08  ASTMC302 

01/D09  ASTMC303 

01/D11  ASTMC356 

01/D12  ASTMC411 

01/D24       ASTM  C739  (Sec.  12) 

01/D27       ASTM  C739  (Sec.  8) 

Related  Material  Properties 

01/V04  ASTME96 

Strength 

01/S01a      ASTM  CI 65  (Proc.  A  only) 

01/S02       ASTM  C203 

01/S08  ASTMC446 

Thermal  Resistance 

01/T01       ASTM  CI 77 

01/T05       ASTM  C335 

01/T06       ASTM  C5 18 

01/T09  ASTMC653 

01/T10  ASTMC687 

01/T1 1       ASTM  C976 


NVLAP  1999  DIRECTORY  -  Page  D4 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  100113-0 
Holometrix  -  Micromet 

25  Wiggins  Avenue 

Bedford,  MA  01730-2323 

Contact:  Mr.  Timothy  Kunz 

Phone:  781-275-3300  x245 

Fax:  781-275-3705 

E-Mail:  info@holometrix.com 

URL:  http://www.holometrix.com 

Thermal  Insulation  Materials 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

Thermal  Resistance 

01/T01  ASTMC177 
01/T05       ASTM  C335 

01/T06  ASTMC518  

NVLAP  LAB  CODE  100120-0 
Commercial  Testing  Company 

1215  South  Hamilton  Street 

P.O.  Box  985 

Dalton,  GA  30722-0985 

Contact:  Mr.  Jonathan  Jackson 

Phone:  706-278-3935 

Fax:  706-278-3936 

E-Mail:  ctctest@alltel.net 

Carpet  and  Carpet  Cushion 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

Tests  Applicable  to  Carpet  Cushion 

03/U01a     ASTM  D3574  (Sec.  8.2  &  Test  A) 

03/U0 1  b     ASTM  D3676  (Sees.  10-12) 

03/U02       ASTM  D297 

03/U06       ASTM  D 1 667  (Suffix  B) 

03/U07       ASTM  D3574  (Test  C) 

03/U08       ASTM  D3574  (Test  D) 

03/U09       ASTM  D3574  (Test  E) 

03/U10  ASTMD3676(Sec.l3) 

03/U11       ASTM  D3676  (Sec.  14) 

03/U12       ASTM  D3676  (Sec.  15) 

03/U13       ASTM  D3676  (Sec.  1 6) 

Tests  Applicable  to  Carpet  and  Carpet  Cushion 

03/T0 1       AATCC  1 6  (Option  E) 

03/T02       ASTM  D2646  (Sees.  16-24) 

03/T03       ASTM  E84 

03/T04       16  CFR  Part  1630  (FF-1-70) 

Tests  Applicable  to  Carpets 


03/G03 

AATCC  134 

03/G04 

AATCC  165 

03/G05 

ASTMD418(Sec.  8) 

03/G06 

ASTM  D418(Sec.  9) 

03/G07 

ASTMD418  (Sees.  10-11) 

03/G08 

ASTM  D418  (Sec.  13) 

03/G09 

ASTM  D1335 

03/G10 

ASTM  D3936 

03/G12 

ASTM  E648 

03/G13  ASTME662  

NVLAP  LAB  CODE  100139-0 
American  Carpet  Laboratories,  Inc. 

75 17  Nashville  Street 

P.O.  Box  357 

Ringgold,  GA  30736 

Contact:  Mr.  Michael  D.  Connell 

Phone:  706-935-5672 

Fax:  706-891-5713 


Carpet  and  Carpet  Cushion 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

Tests  Applicable  to  Carpet  Cushion 

03/U0 1  b  ASTM  D3676  (Sees.  10-12) 

03/U02  ASTM  D297 

03/U08  ASTM  D3574  (Test  D) 

03/U10  ASTMD3676  (Sec.l3) 

03/U12  ASTM  D3676  (Sec.  15) 

03/U13  ASTMD3676  (Sec.l6) 

Tests  Applicable  to  Carpet  and  Carpet  Cushion 

03/T01  AATCC  16  (Option  E) 

03/T02  ASTM  D2646  (Sees.  16-24) 

03/T04  16  CFR  Part  1630  (FF-1-70) 

Tests  Applicable  to  Carpets 

03/G01  AATCC  20 

03/G02  AATCC  20A 

03/G04  AATCC  165 

03/G05  ASTM  D41 8  (Sec.  8) 

03/G06  ASTM  D4 18  (Sec.  9) 

03/G07  ASTM  D41 8  (Sees.  10-11) 

03/G08  ASTM  D418  (Sec.  13) 

03/G09  ASTM  D 1335 

03/G10  ASTM  D3936 

03/G12  ASTM  E648 

03/G13  ASTME662 

03/G14  Fed  Spec,  DDD-C-0095A 

NVLAP  LAB  CODE  100142-0 

Geoscience  Ltd. 

6260-B  Marindustry  Drive 
San  Diego,  C A  92121 
Contact:  Dr.  Ft.  F.  Poppendiek 
Phone:  619-453-5483 
Fax: 619-453-4694 


Thermal  Insulation  Materials 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

Flammability 

01/F05  ASTME136 
Thermal  Resistance 

01/T01  ASTM  CI 77 
01/T04       ASTM  C236 


NVLAP  1999  DIRECTORY  -  Page  D5 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  100146-0 
American  Testing  Laboratories,  Inc. 

784  Flory  Mill  Road 
P.O.  Box  4014 
Lancaster,  PA  17604-4014 
Contact:  Mr.  John  S.  Kassees 
Phone:  717-569-0488 
Fax:  717-569-3429 


NVLAP  LAB  CODE  100156-0 
Mohawk  Industries,  Inc.-  Lyerly  Plant 

Route  1,  Box  32,  Highway  1 14 
Lyerly,  GA  30730 
Contact:  Mr.  Richard  Turner 
Phone:  706-895-3341  x6250 
Fax:  706-895-2346 


Construction  Materials  Testing 

Accreditation  Valid  Through:  March  31,  1999 
NVLAP 

Code  Designation 


Aggregates 
02/A03  ASTM 


02/A04 

02/A06 

02/A07 

02/A09 

02/A10 

02/A11 

02/A12 

02/A44 

02/A46 

Cement 

02/A5 1 

02/A52 

Concrete 

02/A01 

02/A02 

02/A41 

02/A43 

02/A45 

02/G01 

02/G02 


ASTM 
ASTM 
ASTM 
ASTM 
ASTM 
ASTM 
ASTM 
ASTM 
ASTM 

ASTM 
ASTM 

ASTM 
ASTM 
ASTM 
ASTM 
ASTM 
ASTM 
ASTM 


Soil  and  Rock 

02/L02  ASTM 


02/L04 
02/L05 
02/L06 
02/L08 
02/L11 
02/L13 
02/L16 
02/L17 
02/L20 
02/L23 
02/L25 


ASTM 
ASTM 
ASTM 
ASTM 
ASTM 
ASTM 
ASTM 
ASTM 
ASTM 
ASTM 
ASTM 


C29 

C40 

C88 

CI  1 7 

C127 

C128 

C131 

C136 

C566 

C535 

C780  (Annex  A7) 
C1019 

C39 
C617 
C192 
CI  064 
C42 

C31/C172/C143/C138/C231 
C173 

D422 

D698 

D854 

Dl  140 

D1557 

D2166 

D2216 

D2487 

D2488 

D4318 

D2922 

D3017 


Carpet  and  Carpet  Cushion 

Accreditation  Valid  Through:  December31,  1999 
NVLAP 

Code  Designation 

Tests  Applicable  to  Carpet  and  Carpet  Cushion 

03/T01       AATCC  16  (Option  E) 
03/T02       ASTM  D2646  (Sees.  16-24) 
03/T04        16  CFR  Part  1630  (FF-1-70) 
Tests  Applicable  to  Carpets 
03/G04       AATCC  165 
03/G05       ASTM  D4 18  (Sec.  8) 
03/G06       ASTM  D41 8  (Sec.  9) 
03/G07       ASTM  D4 1 8  (Sees.  10-11) 
03/G08       ASTM  D418  (Sec.  13) 
03/G09       ASTM  Dl 335 
03/G10       ASTM  D3936 

NVLAP  LAB  CODE  100166-0 
Independent  Textile  Testing  Service,  Inc. 

1503  Murray  Avenue,  P.O.  Box  1948 

Dalton,  GA  30722-1948 

Contact:  Mr.  L.  Kent  Suddeth 

Phone:  706-278-3013 

Fax:  706-272-7057 

E-Mail:  ittslab@dalton.net 

URL:  ittslab.com 

Carpet  and  Carpet  Cushion 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

Tests  Applicable  to  Carpet  Cushion 

03/U01a  ASTM  D3574  (Sec.  8.2  &  Test  A) 

03/U01b  ASTM  D3676  (Sees.  10-12) 

03/U02  ASTM  D297 

03/U03  ASTM  D629(Sec.  10) 

03/U04  ASTM  D629  (Sees.  13-22) 

03/U05  ASTM  D629  (Sees.  23-27) 

03/U06  ASTM  D1667  (Suffix  B) 

03/U07  ASTM  D3574  (Test  C) 

03/U08  ASTM  D3574  (Test  D) 

03/U09  ASTM  D3574  (Test  E) . 

03/U10  ASTM  D3676  (Sec. 13) 

03/U11  ASTM  D3676  (Sec.  14) 

03/U12  ASTMD3676  (Sec.l5) 

03/U13  ASTM  D3676  (Sec.  16) 

Tests  Applicable  to  Carpet  and  Carpet  Cushion 

03/T01  AATCC  16  (Option  E) 

03/T02  ASTM  D2646  (Sees.  16-24) 

03/T04  16  CFR  Part  1630  (FF-1-70) 


NVLAP  1999  DIRECTORY  -  Page  D6 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Tests  Applicable  to  Carpets 

03/G01  AATCC  20 

03/G02  AATCC  20A 

03/G03  AATCC  134 

03/G04  AATCC  165 

03/G05  ASTMD418  (Sec.  8) 

03/G06  ASTM  D4 1 8  (Sec.  9) 

03/G07  ASTM  D418  (Sees.  10-11) 

03/G08  ASTM  D418  (Sec.  13) 

03/G09  ASTM  D1335 

03/G10  ASTM  D3  93  6 

03/G11  ASTM  D5252 

03/G12  ASTME648 

03/G13  ASTME662 

03/G 1 4  Fed  Spec,  DDD-C-0095  A 

NVLAP  LAB  CODE  100190-0 
Beaulieu  of  America  -  Carpet  Testing  Lab 

1502  Coronet  Drive 

P.O.  Box  1248 

Dal  ton,  GA  30722-1248 

Contact:  Mr.  E.  Ronald  Vinyard 

Phone:  706-259-4511  x7367 

Fax:  706-259-2211  x7893 


Carpet  and  Carpet  Cushion 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

Tests  Applicable  to  Carpet  and  Carpet  Cushion 

03/T0 1       AATCC  1 6  (Option  E) 

03/T02       ASTM  D2646  (Sees.  16-24) 

03/T04       16  CFR  Part  1630  (FF-1-70) 

Tests  Applicable  to  Carpets 

03/G04       AATCC  165 

03/G05       ASTM  D4 18  (Sec.  8) 

03/G06       ASTM  D418  (Sec.  9) 

03/G07       ASTM  D4 18  (Sees.  10-11) 

03/G08       ASTM  D418  (Sec.  13) 

03/G09       ASTM  D 133 5 

03/G10       ASTM  D3936  

NVLAP  LAB  CODE  100191-0 

STS  Consultants,  Ltd. 

750  Corporate  Woods  Parkway 
Vernon  Hills,  IL  60061 
Contact:  Mr.  William  P.  Quinn 
Phone:  847-279-2500 
Fax:  847-279-2550 
E-Mail:  quinn@stsltd.com 

Construction  Materials  Testing 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 
Aggregates 

02/A03  ASTM  C29 
02/A04  ASTM  C40 
02/A06       ASTM  C88 


02/A07  ASTM  CI  17 

02/A09  ASTM  CI 27 

02/A10  ASTM  CI 28 

02/A11  ASTM  CI 31 

02/A12  ASTM  CI 36 

02/A13  ASTM  CI 42 

02/A15  ASTMD75 

02/A46  ASTM  C535 
Cement 

02/A17  ASTM  CI 09 
Concrete 

02/A01  ASTMC39 

02/A02  ASTM  C6 17 

02/A40  ASTM  C78 

02/A41  ASTM  CI 92 

02/A45  ASTM  C42 

02/G01  ASTM  C31/C172/C143/C138/C231 

02/G02  ASTM  CI 73 

Road  and  Paving  Materials 

02/M03  ASTM  D 140 

02/M09  ASTM  D 1074 

02/M11  ASTM  Dl  188 

02/M12  ASTM  D1559 

02/M19  ASTM  D2 172 

02/M24  ASTM  D2041 

02/M25  ASTM  D2726 

Soil  and  Rock 

02/L02  ASTM  D422 

02/L03  ASTM  D427 

02/L04  ASTM  D698 

02/L05  ASTM  D854 

02/L06  ASTM  Dl  140 

02/L08  ASTM  D 1557 

02/L10  ASTM  Dl  883 

02/L11  ASTM  D2 166 

02/L13  ASTM  D2216 

02/L15  ASTM  D2435 

02/L16  ASTM  D2487 

02/L17  ASTM  D2488 

02/L18  ASTM  D3080 

02/L20  ASTM  D4318 

02/L21  ASTM  D2434 

02/L22  ASTM  D2850 

02/L23  ASTM  D2922 

02/L24  ASTM  D2974 

02/L26  ASTM  D4221 

02/L29  Corps  of  Engineers  -  Manual 

EM-1 1 10-2-1906,  Appendix  VII,  Permeability 
of  Fine  Grained  Soils  Using  a  Triaxial 
Apparatus 

02/L30  Corps  of  Engineers  -  Manual 

EM-1 1 10-2-1906,  Appendix  X,  Consolidated 
Undrained  and  Consolidated  Drained  Triaxial 
Test 

02/L46  ASTM  D5084 
Standard  Practices 

02/A38  ASTM  E329 

02/A39  ASTM  CI 077 

02/L32  ASTM  D3740 

02/M26  ASTM  D3666 


NVLAP  1999  DIRECTORY  -  Page  D7 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  100193-0 
Shaw  Industries,  Inc.,  Central  Laboratory 
Operations 

South  Glenwood  Avenue 

P.O.  Box  2128 

Dalton,  GA  30722-2128 

Contact:  Mr.  Jerry  T.  Wright,  Jr. 

Phone:  706-275-2205 

Fax:  706-275-2221 

E-Mail:  jay.wright@shawinc.com 

Carpet  and  Carpet  Cushion 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Tests  Applicable  to  Carpet  and  Carpet  Cushion 


03/T01 

AATCC  16  (Option  E) 

03/T02 

ASTMD2646  (Sees.  16 

03/T04 

16CFR  Part  1630  (FF-1 

Tests  Applicable  to  Carpets 

03/G04 

AATCC  165 

03/G06 

ASTMD418(Sec.  9) 

03/G07 

ASTM  D418  (Sees.  10-1 

03/G08 

ASTM  D418  (Sec.  13) 

03/G09 

ASTM  D1335 

03/G10 

ASTM  D3936 

03/G12 

ASTM  E648 

03/G13 

ASTM  E662 

NVLAP  LAB  CODE  100197-0 

World  Carpets,  Inc. 

One  World  Plaza 

P.O.  Box  1448 

Dalton,  GA  30720-1448 

Contact:  Mr.  Wayne  Murdock 

Phone:  706-278-8000 

Fax:  706-278-4982 

E-Mail:  worldtechlab@juno.com 

Carpet  and  Carpet  Cushion 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

Tests  Applicable  to  Carpet  and  Carpet  Cushion 

03/T01       AATCC  16  (Option  E) 
03/T02       ASTM  D2646  (Sees.  16-24) 
03/T04       16  CFR  Part  1630  (FF-1 -70) 
Tests  Applicable  to  Carpets 
03/G04       AATCC  165 
03/G06       ASTM  D41 8  (Sec.  9) 
03/G07       ASTM  D4 1 8  (Sees.  1 0- 1 1 ) 
03/G08       ASTM  D418  (Sec.  13) 
03/G09       ASTM  D 1335 
03/G10       ASTM  D3936 


NVLAP  LAB  CODE  100210-0 
Flexible  Products  Company 

2050  North  Broadway 
Joliet,IL  60435-3187 
Contact:  Mr.  Robert  Braun 
Phone:  815-774-6500  x1560 
Fax:  815-774-6522 
E-Mail:  rbraun@flexpro.com 

Thermal  Insulation  Materials 

Accreditation  Valid  Through:  December  31,  1999 

NVLAP 

Code  Designation 

Mass,  Density,  and  Dimensional  Stability 

01/D15       ASTM  D756  (Proc.  A) 
0 1  /D 1 6       ASTM  D756  (Proc.  B) 
01/D17       ASTM  D756  (Proc.  E) 
01/D18       ASTM  D1622 
01/D19       ASTM  D2126 
01/D23       ASTM  D2842 
Related  Material  Properties 
01/V04       ASTM  E96 
Strength 

01/S02  ASTMC203 

01/S07  ASTMC273 

01/S1 1       ASTM  D 1 62 1  (Proc.  A) 

Thermal  Resistance 

01/T06       ASTM  C5 18 

NVLAP  LAB  CODE  100227-0 
Riverbank  Acoustical  Laboratories 

1512  S.  Batavia  Avenue 
P.O.  Box  189 
Geneva,  IL  60134-3302 
Contact:  Mr.  John  W.  Kopec 
Phone:  630-232-0104 
Fax:  630-232-0138 
E-Mail:  ral@imaxx.net 

Acoustical  Testing  Services 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP 

Code 

Designation 

08/P03 

ASTM  C423  (ISO  354) 

08/P05 

ASTMC523 

08/P06 

ASTM  E90  (ISO  140,  Part  3) 

08/P07 

ASTM  E492 

08/P10 

ANSIS12.31  (ISO  3741) 

08/P30 

ASTM  El 408 

08/P39 

ANSI  SI 2.5  (ISO  6926) 

NVLAP  1999  DIRECTORY  -  Page  D8 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  100228-0 
Armstrong  Acoustic  Labs,  Armstrong  World  Ind., 
Inc.  Innov.  Center 

P.O.  Box  35 11 

2500  Columbia  Avenue 

Lancaster,  PA  17604 

Contact:  Mr.  Robert  Alan  Hallman 

Phone:  717-396-6225 

Fax:  717-396-5865 

E-Mail:  Robert_A_Hallman@armstrong.com 

Acoustical  Testing  Services 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

08/P03       ASTM  C423  (ISO  354) 
08/P07       ASTM  E492 
08/P28       ASTM  El 375 
08/P29       ASTM  El 376 
08/P33  ASTME1111 

08/P34       ASTM  E1414  (AMA-l-II-67)(ISO  140,  Part  9) 
NVLAP  LAB  CODE  100239-0 

Hufcor  Laboratory 

1017  South  Jackson  Street 
P.O.  Box  591 

Janesville,  WI  53547-0591 

Contact:  Mr.  Todd  A.  Williams 

Phone:  608-758-8329 

Fax:  608-758-8300 

E-Mail:  twilliams@hufcor.com 

Acoustical  Testing  Services 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

08/P06       ASTM  E90  (ISO  140,  Part  3) 

08/P31  ASTME336   

NVLAP  LAB  CODE  100247-0 
Hollytex  Carpet  Mills,  Inc. 

505  N.E.  7th 
P.O.  Box  369 

Anadarko,  OK  73005-2299 
Contact:  Ms.  Carla  McCathern 
Phone:  405-247-7453 
Fax:  405-247-9303 


Carpet  and  Carpet  Cushion 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Tests  Applicable  to  Carpet  and  Carpet  Cushion 

03/T01       AATCC  16  (Option  E) 
03/T04       1 6  CFR  Part  1 63  0  (FF- 1  -70) 
Tests  Applicable  to  Carpets 
03/G04       AATCC  165 


03/G09       ASTM  D1335 

03/G10       ASTM  D3936  

NVLAP  LAB  CODE  100248-0 
Knauf  Fiber  Glass  Research  Laboratory 

240  Elizabeth  Street 
Shelby ville,  IN  46176-1496 
Contact:  Mr.  Timothy  R.  Jonas 
Phone:  317-398-4434 
Fax:  317-398-3675 


Thermal  Insulation  Materials 

Accreditation  Valid  Through:  March  31,  1999 
NVLAP 

Code  Designation 

Mass,  Density,  and  Dimensional  Stability 

01/D02  ASTM  CI 67 
01/D08  ASTM  C302 
01/D09  ASTM  C303 
01/D11  ASTMC356 
01/D12  ASTMC411 
01/D13  ASTM  C5 19 
Strength 

01/S01a      ASTM  CI 65  (Proc.  A  only) 
Thermal  Resistance 

0 1  /TO  1  ASTM  CI 77 
01/T05  ASTMC335 
01/T06  ASTM  C5 18 
01/T09       ASTM  C653 

01/T10  ASTMC687  

NVLAP  LAB  CODE  100251-0 
St.  of  California,  Bur.  of  Home  Furnishings  & 
Thermal  Insulation 

3485  Orange  Grove  Avenue 
North  Highlands,  CA  95660-5595 
Contact:  Dr.  Stephen  J.  Fischer 
Phone:  916-574-2060 
Fax:  916-574-2449 


Thermal  Insulation  Materials 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 
Corrosiveness 

01/C01       ASTM  C739  (Sec.  9) 
01/C02       16  CFR-Part  1209.5 
Flammability 

01/F07        16  CFR-Part  1209.6 
01/F08        16  CFR-Part  1209.7 
01/F09       ASTM  C739  (Sec.  10) 
01/F10       ASTM  C739  (Sec.  14) 
Mass,  Density,  and  Dimensional  Stability 
01/D02       ASTM  CI 67 
01/D08  ASTMC302 
01/D09  ASTMC303 
01/D26       16  CFR-Part  1209.4 


NVLAP  1999  DIRECTORY  -  Page  D9 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


01/D27       ASTM  C739  (Sec.  8) 
Thermal  Resistance 
01/T01       ASTM  CI 77 
01/T05  ASTMC335 


NVLAP  LAB  CODE  100252-0 

D/L  Laboratories 

1 1 6  East  1 6th  Street 
New  York,  NY  10003-2174 
Contact:  Mr.  Saul  Spindel 
Phone:  212-777-4445 
Fax:  212-505-8419 
E-Mail:  dllabs@aol.com 

Commercial  Products  Testing 

Accreditation  Valid  Through:  December  31,  1999 

NVLAP 

Code  Designation 

Building  Seals  and  Sealants 

13/O01  ASTM  C5 10 

13/O02a  ASTMC603 

13/O02b  CAN2-19.0-M77,  Meth.  3.1 

13/003  ASTMC639 

13/O04a  ASTMC661 

13/O04b  CAN2-19.0-M77,  Meth.  8.1 

13/O05a  ASTMC679 

1 3/O05b  CAN2- 1 9.0-M77,  Meth.  2. 1 

13/006  ASTMC681 

13/007  ASTM  C7 11 

13/008  ASTM  C7 12 

13/009  ASTM  C7 13 

13/O10  ASTM  C7 18 

13/01  la  ASTMC719 

1 3/0 1 1  b  CAN2- 1 9.0-M77,  Meth.  14.4 

13/012  ASTMC731 

13/013  ASTMC732 

13/014  ASTMC733 

13/015  ASTMC734 

13/016  ASTMC736 

13/017  ASTM  C741 

13/018  ASTMC742 

13/01 9a  ASTMC792 

13/0 19b  CAN2-19.0-M77,  Meth.  5.1 

13/020  ASTMC793 

13/021  ASTMC794 

13/022  ASTM  C9 10 

13/023  ASTM  D2202 

13/024  ASTM  D2203 

13/025  ASTM  D2376 

13/026  ASTM  D2377 

13/027  ASTM  D2450 

13/028  ASTM  D245 1 

13/029  ASTM  D2452 

13/030  ASTM  D2453 

1 3/03 1  CAN2- 1 9.0-M77,  Meth.  7. 1 

13/032  CAN2-19.0-M77,  Meth.  7.3 

13/033  CAN2-19.0-M77,  Meth.  8.2 

13/034  CAN2-19.0-M77,  Meth.  11.1 

13/035  CAN2-19.0-M77,  Meth.  14.7 

13/036  CAN2-19.0-M77,  Meth.  19.2 

13/037  ASTMC920 


13/038  ASTM  CI 241 

13/039  ASTM  CI  183 

13/040  ASTM  CI 246 

13/041  CAN2-19.0-M77,  Meth.  9.1 

1 3/042  CAN2- 1 9.0-M77,  Meth.  9.2 

13/043  CAN2-19.0-M77,  Meth.  14.6 

13/044  CAN2-19.0-M77,  Meth.  18.2 

13/045  ASTMC834 

Paints  and  Related  Coatings  and  Materials 

09/A01  ASTMD56 

09/A02  ASTM  D93  (Method  A) 

09/A03  ASTM  D 153 

09/A04  ASTM  D 185 

09/A05  ASTMD281 

09/A07  ASTM  D523 

09/A08  ASTM  D562 

09/A09  ASTM  D 1005 

09/A10  ASTM  Dl  186 

09/A11  ASTM  D 1200 

09/A12  ASTM  Dl 210 

09/A 1 3  ASTM  D 1 2 1 2  (Method  A) 

09/A14  ASTM  D 1296 

09/A15  ASTM  D1310 

09/A  16  ASTM  D 1400 

09/A  17  ASTM  D 1475 

09/A  18  ASTM  D 1544 

09/A  19  ASTM  D 1729 

09/A20  ASTM  D2244 

09/A21  ASTM  D3278 

09/A22  ASTM  D3363 

09/A23  ASTM  D3793 

09/A25  ASTM  D4212 

09/A26  ASTM  El 347 

09/A28  ASTM  E3 13 

09/A30  CGSB  Method  1  -GP-7 1 ,  Meth.  10.1 

09/A31  CGSB  Method  1 -GP-7 1,  Meth.  12.8 

09/A32  CGSB  Method  l-GP-71,  Meth.  45.1 

09/A33  ASTM  D2 196 

09/B02  ASTM  D332 

09/B03  ASTM  D344 

09/B04  ASTM  D6 10 

09/B05  ASTM  D4214 

09/B06  ASTM  D660 

09/B07  ASTMD661 

09/B08  ASTM  D662 

09/B09  ASTM  D7 11 

09/B10  ASTM  D7 14 

09/B11  ASTMD772 

09/B12  ASTMD868 

09/B13a  ASTMD968 

09/B13b  CGSB  Method  l-GP-71  Meth.  104.1 

09/B14  ASTMD869 

09/B15  ASTMD870 

09/B16  ASTM  D9 13 

09/B18  ASTMD969 

09/B19a  ASTM  D 1308 

09/B19b  CGSB  Method  l-GP-71 ,  Meth.  105.1 

09/B 1 9c  CGSB  Method  1  -GP-7 1 ,  Meth.  1 06. 1 

09/B 1 9d  CGSB  Method  1  -GP-7 1 ,  Meth.  1 07. 1 

09/B  1 9e  CGSB  Method  1  -GP-7 1 ,  Meth.  1 1 0. 1 

09/B20  ASTM  D 1309 

09/B23  ASTM  D 1640 


NVLAP  1999  DIRECTORY  -  Page  D10 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


09/B24 

ASTM  D522 

09/C44 

ASTM  D5095 

09/B25 

ASTM  D2197 

09/C45 

CGSB  Method  l-GP-71,  Meth.  69.3 

09/B26 

ASTM  D2243 

09/D01 

ASTM  Bl  17 

09/B27 

ASTM  D2248 

09/D02 

ASTM  D609 

09/B29 

ASTM  D2486 

09/D03 

ASTM  D822 

09/B31 

ASTM  D2805 

09/D04 

ASTM  D823  (Limited  to  Practices  B,  C,  D  and 

09/B32 

ASTM  D3273 

E) 

09/B33 

ASTM  D3274 

09/D05 

ASTM  D 1006 

09/B34 

ASTM  D3450 

09/D06 

ASTM  D1014 

09/B37 

ASTM  D4060 

09/D07 

ASTM  D1654 

09/B38 

ASTM  D4062 

09/D13 

ASTM  D3924 

09/B39 

ASTM  D4213 

09/D14 

ASTM  G23 

09/B41 

Fed.  Std.  141,  Method  4494 

09/D16 

ASTM  G53 

09/B42 

red.  Std.  141,  Method  4061 

09/D17 

ASTM  D4446 

09/B43 

ASTM  D3359 

09/D18 

ASTM  D5401 

09/B44 

ASTM  D4828 

Plastics 

09/B45 

CGSB  Method  l-GP-71,  Meth.  14.1 

15/A26 

ASTM  D2240 

09/B46a 

ASTM  D 1849 

09/B46b 

CGSB  Method  l-GP-71,  Meth.  30.3 

NVLAP  LAB  CODE  100255-0 

09/B47 

CGSB  Method  l-GP-71,  Meth.  32.1 

Underwriters  Laboratories,  Inc. 

09/B48 

CGSB  Method  l-GP-71,  Meth.  37.3 

1285  Walt  Whitman  Road 

09/B49 

CGSB  Method  l-GP-71,  Meth.  112.2 

Melville,  NY  11747-3081 

09/B50 

CGSB  Method  l-GP-71,  Meth.  1 14.1 

Contact:  Mr.  Jim  Beyreis 

09/B51 

CGSB  Method  l-GP-71,  Meth.  116.2 

Phone:  847-272-8800 

AO/DO 

CUots  Method  l -ur- / 1 ,  Meth.  IzJ.z 

Fax:  847-272-8129 

no  /d  c  i 

CuohJ  Method  1  -ur- / 1 ,  Meth.  Izj.l 

09/B54 

CGSB  Method  l-GP-71,  Meth.  127.1 

URL:  http://www.ul.com 

09/B55 

CGSB  Method  l-GP-71,  Meth.  130.1 

FCC  Test  Methods 

09/B56 

CGSB  Method  l-GP-71,  Meth.  131.2 

Accreditation  Valid  Through:  September  30,  1999 

09/B57 

CGSB  Method  l-GP-71,  Meth.  132.1 

NVLAP 
Code 

09/B58 

CGSB  Method  l-GP-71,  Meth.  134.1 

Designation 

09/B59 

CGSB  Method  l-GP-71,  Meth.  135.1 

09/B59 

CGSB  Method  l-GP-71,  Meth.  135.1 

AUSTEL  Technical  Standards  as  determined  under  the 

09/B60 

CGSB  Method  l-GP-71,  Meth.  142.1 

Telecommunications  Act  of  1991 

09/B61 

ASTM  D412 

12/T41 

TS-001 

(\C\  /T~»  ^ 

09/B62 

ASTM  D1653 

12/T42 

TS-002 

09/B63 

ASTM  D2134 

12/T44 

TS-004 

Uy/r>04 

As  1 M  DZJ  /0 

12/T45 

TS-006 

A.O  1  ivl  LOZjo 

12/T46 

TS-008 

AS  1  M  JJjoUO 

Australian 

Standards  referred  to  by  clauses  in  AUSTEL 

09/B67 

ASTM  D4400 

Technical  Standards 

09/B68 

ASTM  D4541 

AS/NZS  3260 

12/T50 

09/B69 

ASTM  D4707 

12/T51 

AS/NZS  3548 

09/B70 

ASTM  D4946 

09/B71 

ASTM  D2794 

Federal  Communications  Commission  (FCC)  Methods 

09/C07 

ASTM  Dl  133 

12/F01 

FCC  Method  -  47  CFR  Part  15  -  Digital 

09/C09 

ASTM  D1259 

Devices 

09/C11 

ASTM  D1353 

12/F01a 

Conducted  Emissions,  Power  Lines,  450  KHz 

09/C12 

ASTM  D 1364 

to  30  MHz 

c\C\ 

09/C22 

AS  1M  U1644 

12/F01b 

Radiated  Emissions 

09/C26a 

ASTM  D2369 

12/T01 

Terminal  Equipment  Network  Protection 

uy/czoD 

L,(jsh>  Method  l-ur  - / 1 ,  Meth.  1  /.  1 

Standards,  FCC  Method  -  47  CFR  Part  68  - 

L-Oot>  Metnoa  i-vjr-/ 1,  Metn. 

Analog  and  Digital 

09/C27 

ASTM  D2371 

12/T01a 

68.302  (Par.  c,d,e,f)  Environmental  simulation; 

09/C28 

ASTM  D2697 

68.304  Leakage  current  limit.;  68.306 

09/C29 

ASTM  D2698 

Hazardous  voltage  limit.;  68.308  Signal  power 

09/C30 

ASTM  D2832 

09/C37 

ASTM  D3723 

limit.;  68.310  Longitudinal  balance  limit.; 

09/C39 

ASTM  D3960 

68.312  On-hook  impedance  limit.;  68.314 

09/C40 

ASTM  D4017 

Billing  protection 

09/C42 

CGSB  Method  l-GP-71,  Meth.  21.1 

12/T01b 

68.316  Hearing  Aid  Compatibility:  technical 

09/C43 

CGSB  Method  l-GP-71,  Meth.  24.1 

standards 

NVLAP  1999  DIRECTORY  -  Page  Dl  1  (See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


12/T01c      68.302  Environmental  simulation  (Par.  a,b) 
International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/C1SPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  100256-0 
Western  Electro-Acoustic  Lab.,  Inc. 

1711  16th  Street 
Santa  Monica,  CA  90404 
Contact:  Mr.  Gary  E.  Mange 
Phone: 310-450-1733 
Fax:  310-396-3424 

E-Mail:  gmange@veneklasen-assoc.com 

Acoustical  Testing  Services 

Accreditation  Valid  Through:  March  31,  1999 
NVLAP 

Code  Designation 

08/P03       ASTM  C423  (ISO  354) 
08/P06       ASTM  E90  (ISO  140,  Part  3) 
08/P31        ASTM  E3  3  6 
OS/P32        ASTM  I  Mil)- 

N  VLAP  LAB  CODE  100259-0 
MacMillan  Bloedel  Packaging,  Inc.,  Combined 
Board  Test  Lab 

Highway  10  East 

P.O.  Box  336 

Pine  Hill,  AL  36769-5336 

Contact:  Mr.  Don  White 

Phone:  334-963-4391 

Fax:  334-963-4887 


Commercial  Products  Testing 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Paper  and  Related  Products 

09/E02  TAPPI  T402-OM;  ASTM  D685 

09/E05  TAPPI  T410-OM 

09/E06  TAPPI  T411-OM 

09/E07  TAPPI  T412-OM;  ASTM  D644 

09/E08  TAPPI  T414-OM 

09/E12  TAPPI  T459-OM;  ASTM  D2482 

09/E13  TAPPI  T460-OM;  ASTM  D726 

09/E20  TAPPI  T809-OM 

09/E22  TAPPI  T807-OM 

09/E25  TAPPI  T826-PM 

09/E30  TAPPI  T822-OM 

09/H0 1  ASTM  D642;  TAPPI  T804-OM 

09/H26  TAPPI  UM-807 

09/H28  TAPPI  T810-OM 

09/H29  TAPPI  T811-OM 

09/H30  TAPPI  T821-OM 

09/H31  TAPPI  T825-PM 


NVLAP  LAB  CODE  100261-0 
Resources,  Applications,  Designs  &  Control,  Inc. 
(RADCO) 

3220  E.  59th  Street 

Long  Beach,  CA  90805-4502 

Contact:  Mr.  Michael  L.  Zieman,  P.E. 

Phone:  562-272-7231 

Fax:  562-529-7513 

E-Mail:  Mzieman@Radcoinc.com 

Thermal  Insulation  Materials 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

Mass,  Density,  and  Dimensional  Stability 

01/D07       ASTM  C272 
01/D09       ASTM  C303 
01/D19       ASTM  D2126 
Related  Material  Properties 
01/V04  ASTME96 
Strength 

01/S02       ASTM  C203 
01/S10  ASTMD828 
01/S11        ASTM  D1621  (Proc.  A) 
Thermal  Resistance 
01/T06       ASTM  C5 18 

NVLAP  LAB  CODE  100267-0 
Retlif  Testing  Laboratories 

795  Marconi  Avenue 
Ronkonkoma,  NY  1 1 779-723 1 
Contact:  Mr.  Ross  A.  Hansen 
Phone:  516-737-1500 
Fax:  516-737-1497 
E-Mail:  rhansen@retlif.com 
URL:  http://www.retlif.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 

NVLAP 

Code  Designation 

AUSTEL  Technical  Standards  as  determined  under  the 
Telecommunications  Act  of  1991 

12/T42  TS-002 
12/T43  TS-003 
12/T44  TS-004 
12/T45  TS-006 
12/T46  TS-008 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 

1 2/FO 1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 
1 2/TO 1       Terminal  Equipment  Network  Protection 

Standards,  FCC  Method  -  47  CFR  Part  68  - 


NVLAP  1999  DIRECTORY  -  Page  D12 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Analog  and  Digital 
12/T01a     68.302  (Par.  c,d,e,f)  Environmental  simulation; 

68.304  Leakage  current  limit.;  68.306 

Hazardous  voltage  limit.;  68.308  Signal  power 

limit.;  68.310  Longitudinal  balance  limit.; 

68.312  On-hook  impedance  limit;  68.314 

Billing  protection 
12/T01b     68.316  Hearing  Aid  Compatibility:  technical 

standards 

12/T01c      68.302  Environmental  simulation  (Par.  a,b) 
International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

MDL-STD-462  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 

NVLAP 

Code  Designation 

Conducted  Emissions: 

1 2/A0 1       MIL-STD-462  Method  CEO  1 

12/A04       MIL-STD-462  Method  CE02 

12/A06       MIL-STD-462  Method  CE03 

12/A08       MIL-STD-462  Method  CE04 

12/A12       MIL-STD-462  Method  CE07 

Conducted  Susceptibility: 

1 2/BO 1       MIL-STD-462  Method  CS0 1 

1 2/B02       MIL-STD-462  Method  CS02 

1 2/B05       MIL-STD-462  Method  CS06 

1 2/B08       MIL-STD-462  Method  CS 1 0 

1 2/B09       MIL-STD-462  Method  CS  1 1 

Radiated  Emissions: 

1 2/DO 1       MIL-STD-462  Method  RE0 1 

12/D02       MIL-STD-462  Method  RE02 

Radiated  Susceptibility: 

1 2/EO 1       MIL-STD-462  Method  RS0 1 

1 2/E02       MIL-STD-462  Method  RS02 

12/E04       MIL-STD-462  Method  RS03  employing 

RADHAZ  procedures  for  high  level  testing 
(Consult  laboratory  for  field  strengths 
available) 

1 2/E05       MIL-STD-462  Method  RS05 

1 2/E07       MIL-STD-462  Method  RS06  

NVLAP  LAB  CODE  100267-1 
Retlif  Testing  Laboratories 

101  New  Boston  Road 
Goffstown,  NH  03045 
Contact:  John  Monahan 
Phone:  603-497-4600 
Fax:  603-497-5281 

URL:  http://www.retlif.com 


FCC  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  la      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
12/F01b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

1 2/CIS22    IEC/CISPR  22: 1 993 :  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  100268-0 
TUV  Product  Service,  Inc. 

10040  Mesa  Rim  Road 
San  Diego,  CA  92121-1034 
Contact:  Mr.  Floyd  R.  Fleury 
Phone:  619-546-3999 
Fax:  619-546-0364 
E-Mail:  cfleury@TUVps.com 
URL:  http://www.tuvps.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/F0 1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  la      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
12/F01b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22: 1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

MIL-STD-462  Test  Methods 

Accreditation  Valid  Through:  December  31,  1999 

NVLAP 

Code  Designation 

Conducted  Emissions: 
1 2/AO 1       MIL-STD-462  Method  CEO  1 
1 2/A04       MIL-STD-462  Method  CE02 
1 2/A06       MIL-STD-462  Method  CE03 
1 2/A08       MIL-STD-462  Method  CE04 


NVLAP  1999  DIRECTORY  -  Page  D13 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


1 2/A 1 0  MIL-STD-462  Method  CE06 
1 2/A1 2  MIL-STD-462  Method  CE07 
Conducted  Susceptibility: 
1 2/BO 1  MIL-STD-462  Method  CSO 1 
1 2/B02  MIL-STD-462  Method  CS02 
12/B04       MIL-STD-462  Method 

CS03/CS04/CS05/CS08 
1 2/B05       MIL-STD-462  Method  CS06 
1 2/B06       MIL-STD-462  Method  CS07 
1 2/B07       MIL-STD-462  Method  CS09 
Radiated  Emissions: 
1 2/DO 1       MIL-STD-462  Method  REO 1 
1 2/D02       MIL-STD-462  Method  RE02 
1 2/D03       MIL-STD-462  Method  RE03 
Radiated  Susceptibility: 
12/E01       MIL-STD-462  Method  RS01 
1 2/E02       MIL-STD-462  Method  RS02 
12/E03       MIL-STD-462  Method  RS03  (Consult 

laboratory  for  field  strengths  available) 
1 2/E04       MIL-STD-462  Method  RS03  employing 

RADHAZ  procedures  for  high  level  testing 

(Consult  laboratory  for  field  strengths 

available) 

NVLAP  LAB  CODE  100269-0 
Intermec  Technologies  Corporation,  Norand 
Mobile  System  Division 

550  Second  Street  S.E. 

Cedar  Rapids,  I A  52401 

Contact:  Mr.  Cednc  Brownfield 

Phone:  319-846-2415 

Fax:  319-846-2475 

E-Mail:  brownfieldcn@norand.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  A  USTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/F0 1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22     IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 


NVLAP  LAB  CODE  100270-0 
Intertek  Testing  Services  NA  Inc. 

70  Codman  Hill  Road 

Boxborough,  MA  01719 

Contact:  Mr.  Roland  W.  Gubisch 

Phone:  978-635-8500 

Fax:  978-263-7086 

E-Mail:  rwg@itsqs.com 

URL:  http://www.worldlab.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

AUSTEL  Technical  Standards  as  determined  under  the 
Telecommunications  Act  of  1991 

12/T41  TS-001 
12/T42  TS-002 
12/T43  TS-003 
12/T44  TS-004 
12/T45  TS-006 
12/T46  TS-008 
12/T49  TS-016 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 

1 2/FO  1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 

Devices 

1 2/FO  1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 
12/T01       Terminal  Equipment  Network  Protection 

Standards,  FCC  Method  -  47  CFR  Part  68  - 

Analog  and  Digital 
12/T01a      68.302  (Par.  c,d,e,f)  Environmental  simulation; 

68.304  Leakage  current  limit.;  68.306 

Hazardous  voltage  limit.;  68.308  Signal  power 

limit.;  68.310  Longitudinal  balance  limit.; 

68.312  On-hook  impedance  limit.;  68.314 

Billing  protection 
12/T01b     68.316  Hearing  Aid  Compatibility:  technical 

standards 

12/TOlc      68.302  Environmental  simulation  (Par.  a,b) 
International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

1 2/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

MIL-STD-462  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 

NVLAP 

Code  Designation 

Conducted  Emissions: 

1 2/AO 1       MIL-STD-462  Method  CEO  1 

1 2/A04       MIL-STD-462  Method  CE02 


NVLAP  1999  DIRECTORY  -  Page  D14 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


12/A06  MIL-STD-462  Method  CE03 
1 2/A08  MIL-STD-462  Method  CE04 
1 2/A 1 0  MIL-STD-462  Method  CE06 
1 2/A 1 2  MIL-STD-462  Method  CE07 
Conducted  Susceptibility: 
1 2/BO 1  MIL-STD-462  Method  CSO 1 
1 2/B02  MIL-STD-462  Method  CS02 
12/B04       MIL-STD-462  Method 

CS03/CS04/CS05/CS08 
1 2/B05  MIL-STD-462  Method  CS06 
1 2/B06  MIL-STD-462  Method  CS07 
1 2/B07  MIL-STD-462  Method  CS09 
1 2/B08  MIL-STD-462  Method  CS 1 0 
1 2/B09  MIL-STD-462  Method  CS  1 1 
1 2/B 1 0  MIL-STD-462  Method  CS  1 2 
12/B1 1  MIL-STD-462  Method  CS  1 3 
Radiated  Emissions: 
1 2/DO 1  MIL-STD-462  Method  REO 1 
1 2/D02  MIL-STD-462  Method  RE02 
1 2/D03  MIL-STD-462  Method  RE03 
Radiated  Susceptibility: 
1 2/EO 1  MIL-STD-462  Method  RSO 1 
1 2/E02  MIL-STD-462  Method  RS02 
12/E03       MIL-STD-462  Method  RS03  (Consult 

laboratory  for  field  strengths  available) 
12/E04       MIL-STD-462  Method  RS03  employing 

RADHAZ  procedures  for  high  level  testing 

(Consult  laboratory  for  field  strengths 

available) 

1 2/E05       MIL-STD-462  Method  RS05 

1 2/E07       MIL-STD-462  Method  RS06  

NVLAP  LAB  CODE  100271-0 
TUV  Product  Service,  Inc. 

1775  Old  Hwy.  8  NW,  Suite  104 
New  Brighton,  MN  551  12-1891 
Contact:  Mr.  Timothy  P.  O'Shea 
Phone:  651-631-2487 
Fax:  651-638-0285 
E-Mail:  toshea@tuvps.com 
URL:  http://www.tuvps.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

AUSTEL  Technical  Standards  as  determined  under  the 
Telecommunications  Act  of  1991 

12/T41  TS-001 
12/T46  TS-008 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T50  AS/NZS  3260 
12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  la      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 


International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR22T993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

MIL-STD-462  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 

NVLAP 

Code  Designation 

Conducted  Emissions: 

1 2/AO 1       MIL-STD-462  Method  CEO  1 

1 2/A04       MIL-STD-462  Method  CE02 

1 2/A06       MIL-STD-462  Method  CE03 

1 2/A08       MIL-STD-462  Method  CE04 

1 2/A  1 2       MIL-STD-462  Method  CE07 

Conducted  Susceptibility: 

1 2/B0 1       MIL-STD-462  Method  CSO  1 

1 2/B02       MIL-STD-462  Method  CS02 

1 2/B05       MIL-STD-462  Method  CS06 

1 2/B07       MIL-STD-462  Method  CS09 

Radiated  Emissions: 

1 2/DO  1       MIL-STD-462  Method  REO  1 

1 2/D02       MIL-STD-462  Method  RE02 

Radiated  Susceptibility: 

1 2/EO  1       MIL-STD-462  Method  RSO  1 

1 2/E02       MIL-STD-462  Method  RS02 

1 2/E03       MIL-STD-462  Method  RS03  (Consult 

laboratory  for  field  strengths  available) 
1 2/E04       MIL-STD-462  Method  RS03  employing 

RADHAZ  procedures  for  high  level  testing 

(Consult  laboratory  for  field  strengths 

available) 

1 2/E07       MIL-STD-462  Method  RS06 

NVLAP  LAB  CODE  100271-1 
TUV  Product  Service,  Inc. 

5541  Central  Avenue 
Boulder,  CO  80301-2846 
Contact:  Jeff  Doolittle 
Phone:  303-402-5241 
Fax:  303-449-3004 
E-Mail:  jdoolittle@tuvps.com 
URL:  http://www.tuvps.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO  1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  1  b      Radiated  Emissions 


NVLAP  1999  DIRECTORY  -  Page  D15 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  100272-0 
Communication  Certification  Laboratory 

1940  West  Alexander  Street 
Salt  Lake  City,  UT  84119-2039 
Contact:  Mr.  William  S.  Hurst 
Phone:  801-972-6146 
Fax:  801-972-8432 
E-Mail:  wsh@cclab.com 
URL:  http://www.cclab.com/ 

FCC  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

AUSTEL  Technical  Standards  as  determined  under  the 
Telecommunications  Act  of  1991 

12/T41  TS-001 
12/T42  TS-002 
12/T43  TS-003 
12/T44  TS-004 
12/T45  TS-006 
12/T46  TS-008 
12/T49  TS-016 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  la      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  1  b      Radiated  Emissions 
12/T01       Terminal  Equipment  Network  Protection 

Standards,  FCC  Method  -  47  CFR  Part  68  - 

Analog  and  Digital 
12/T01a      68.302  (Par.  c,d,e,f)  Environmental  simulation; 

68.304  Leakage  current  limit.;  68.306 

Hazardous  voltage  limit.;  68.308  Signal  power 

limit.;  68.310  Longitudinal  balance  limit.; 

68.312  On-hook  impedance  limit.;  68.314 

Billing  protection 
12/T01b     68.316  Hearing  Aid  Compatibility:  technical 

standards 

12/T01c      68.302  Environmental  simulation  (Par.  a,b) 


NVLAP  LAB  CODE  100273-0 
MET  Laboratories,  Inc. 

914  W.  Patapsco  Avenue 
Baltimore,  MD  21230-3432 
Contact:  Mr.  Robert  Frier 
Phone:  410-354-3300 
Fax:  410-354-3313 
E-Mail:  rfrier@metlabs.com 
URL:  http://www.metlabs.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

AUSTEL  Technical  Standards  as  determined  under  the 

Telecommunications  Act  of  1991 

12/T41  TS-001 

12/T42  TS-002 

12/T43  TS-003 

12/T44  TS-004 

12/T45  TS-006 

12/T46  TS-008 

12/T49  TS-016 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T50  AS/NZS  3260 
12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO  1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  la      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
12/F01b      Radiated  Emissions 
12/T01       Terminal  Equipment  Network  Protection 

Standards,  FCC  Method  -  47  CFR  Part  68  - 

Analog  and  Digital 
12/T01a      68.302  (Par.  c,d,e,f)  Environmental  simulation; 

68.304  Leakage  current  limit.;  68.306 

Hazardous  voltage  limit.;  68.308  Signal  power 

limit.;  68.310  Longitudinal  balance  limit.; 

68.312  On-hook  impedance  limit.;  68.314 

Billing  protection 
12/T01b     68.316  Hearing  Aid  Compatibility:  technical 

standards 

12/TOlc      68.302  Environmental  simulation  (Par.  a,b) 
International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 


NVLAP  1999  DIRECTORY  -  Page  D16 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  100274-0 
Intertek  Testing  Services  NA  Inc. 

73 1  Enterprise  Drive 

Lexington,  KY  40510-1029 

Contact:  Mr.  Clifford  Eugene  Jones, 

Phone: 606-226-1060 

Fax:  606-225-1050 

E-Mail:  Cliff@TestMark.com 

URL:  http://www.testmark.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

AUSTEL  Technical  Standards  as  determined  under  the 

Telecommunications  Act  of  1991 

12/T41  TS-001 

12/T42  TS-002 

12/T43  TS-003 

12/T44  TS-004 

12/T45  TS-006 

12/T46  TS-008 

12/T49  TS-016 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T50  AS/NZS  3260 
12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  la      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
12/F01b      Radiated  Emissions 
12/T01       Terminal  Equipment  Network  Protection 

Standards,  FCC  Method  -  47  CFR  Part  68  - 

Analog  and  Digital 
12/T01a      68.302  (Par.  c,d,e,f)  Environmental  simulation; 

68.304  Leakage  current  limit.;  68.306 

Hazardous  voltage  limit.;  68.308  Signal  power 

limit.;  68.310  Longitudinal  balance  limit.; 

68.312  On-hook  impedance  limit.;  68.314 

Billing  protection 
12/T01b     68.316  Hearing  Aid  Compatibility:  technical 

standards 

12/T01c      68.302  Environmental  simulation  (Par.  a,b) 
International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 


NVLAP  LAB  CODE  100275-0 
Lucent  Technologies,  Global  Product  Compliance 
Lab 

101  Crawfords  Corner  Road,  M/S  1 1C-195 

P.O.  Box  3030 

Holmdel,  NJ  07733-3030 

Contact:  Mr.  E.  Gardner  Burkhardt 

Phone:  732-332-6001 

Fax:  732-332-5999 

E-Mail:  egburkhardt@lucent.com 

URL:  http://www.gpcl.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

AUSTEL  Technical  Standards  as  determined  under  the 
Telecommunications  Act  of  1991 

12/T41  TS-001 
12/T42  TS-002 
12/T44  TS-004 
12/T45  TS-006 
12/T46  TS-008 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO  1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

12/F01a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
12/F01b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  100276-0 
D.L.S.  Electronic  Systems,  Inc. 

1250  Peterson  Drive 

Wheeling,  IL  60090-6454 

Contact:  Mr.  Brian  J.  Mattson 

Phone:  847-537-6400 

Fax:  847-537-6488 

E-Mail:  bmattson@dlsemc.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO  1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 


NVLAP  1999  DIRECTORY  -  Page  D17 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


1 2/FO 1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  100278-0 
Elite  Electronic  Engineering  Company 
1516  Centre  Circle 
Downers  Grove,  IL  60515-1082 
Contact:  Mr.  Raymond  Klouda 
Phone: 630-495-9770 
Fax:  630-495-9785 
E-Mail:  engineenng@elitetest.com 
URL:  http://www.elitetest.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

Federal  Communications  Commission  (FCC)  Methods 


12/F01 


Digital 


1 2/FO la 

1 2/FO  lb 
12/T01 


12/T01b 


12/T01c 


FCC  Method  -  47  CFR  Part  15 
Devices 

Conducted  Emissions,  Power  Lines,  450  KHz 
to  30  MHz 
Radiated  Emissions 

Terminal  Equipment  Network  Protection 
Standards,  FCC  Method  -  47  CFR  Part  68  - 
Analog  and  Digital 
12/T01a      68.302  (Par.  c,d,e,f)  Environmental  simulation; 
68.304  Leakage  current  limit.;  68.306 
Hazardous  voltage  limit.;  68.308  Signal  power 
limit.;  68.310  Longitudinal  balance  limit.; 
68.312  On-hook  impedance  limit.;  68.314 
Billing  protection 

68.316  Hearing  Aid  Compatibility:  technical 
standards 

68.302  Environmental  simulation  (Par.  a,b) 
MIL-STD-462  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

Conducted  Emissions: 
1 2/A0 1       MIL-STD-462  Method  CEO  1 
1 2/A04       MIL-STD-462  Method  CE02 
1 2/A06       MIL-STD-462  Method  CE03 
1 2/A08       MIL-STD-462  Method  CE04 
1 2/A 1 0       MIL-STD-462  Method  CE06 
12/A12       MIL-STD-462  Method  CE07 
Conducted  Susceptibility: 
1 2/B0 1       MIL-STD-462  Method  CS0 1 
1 2/B02       MIL-STD-462  Method  CS02 
12/B04       MIL-STD-462  Method 
CS03/CS04/CS05/CS08 
1 2/B05       MIL-STD-462  Method  CS06 


12/B06 

12/B07 

12/B08 

12/B09 

12/B10 

12/B1 1 

Radiated 

12/D01 

12/D02 

12/D03 

Radiated 

12/E01 

12/E02 

12/E04 


I2/E05 
I2/E07 


MIL-STD-462  Method  CS07 

MIL-STD-462  Method  CS09 

MIL-STD-462  Method  CS10 

MIL-STD-462  Method  CS1 1 

MIL-STD-462  Method  CS12 

MIL-STD-462  Method  CS13 
Emissions: 

MIL-STD-462  Method  RE01 

MIL-STD-462  Method  RE02 

MIL-STD-462  Method  RE03 
Susceptibility: 

MIL-STD-462  Method  RS01 

MIL-STD-462  Method  RS02 

MIL-STD-462  Method  RS03  employing 

RADHAZ  procedures  for  high  level  testing 

(Consult  laboratory  for  field  strengths 

available) 

MIL-STD-462  Method  RS05 
MIL-STD-462  Method  RS06 


NVLAP  LAB  CODE  100280-0 

R  &  B  Enterprises 

20  Clipper  Road 

West  Conshohocken,  PA  1 9428-272 1 

Contact:  Mr.  Rohit  Vohra 

Phone:  610-825-1960 

Fax:  610-825-1684 

E-Mail:  rvohra@RBitem.com 

URL:  www.RBitem.com 

MIL-STD-462  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

Conducted  Emissions: 

1 2/ AO  1       MIL-STD-462  Method  CEO  1 

1 2/A06       MIL-STD-462  Method  CE03 

1 2/A  1 0       MIL-STD-462  Method  CE06 

1 2/A  1 2       MIL-STD-462  Method  CE07 

Conducted  Susceptibility: 

1 2/BO 1       MIL-STD-462  Method  CS0 1 

1 2/B02       MIL-STD-462  Method  CS02 

1 2/B05       MIL-STD-462  Method  CS06 

1 2/B06       MIL-STD-462  Method  CS07 

1 2/B07       MIL-STD-462  Method  CS09 

1 2/B08       MIL-STD-462  Method  CS 1 0 

1 2/B09       MIL-STD-462  Method  CS  1 1 

12/B10       MIL-STD-462  Method  CS  1 2 

1 2/B 1 1       MIL-STD-462  Method  CS  1 3 

Radiated  Emissions: 

12/D01       MIL-STD-462  Method  RE01 

1 2/D02       MIL-STD-462  Method  RE02 

Radiated  Susceptibility: 

1 2/EO 1       MIL-STD-462  Method  RS0 1 

12/E02       MIL-STD-462  Method  RS02 

1 2/E04       MIL-STD-462  Method  RS03  employing 

RADHAZ  procedures  for  high  level  testing 
(Consult  laboratory  for  field  strengths 
available) 

12/E05       MIL-STD-462  Method  RS05 


NVLAP  1999  DIRECTORY  -  Page  D18 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


FCC  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

12/F01a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 

NVLAP  LAB  CODE  100286-0 
Acoustic  Systems  Acoustical  Research  Facility 

415  East  St.  Elmo  Road 

P.O.  Box  3610 

Austin,  TX  78764 

Contact:  Mr.  Michael  C.  Black 

Phone:  512-444-1961 

Fax:  512-444-2282 

E-Mail:  acoustic@inetport.com 

Acoustical  Testing  Services 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

08/P03       ASTM  C423  (ISO  354) 
08/P06       ASTM  E90  (ISO  1 40,  Part  3 ) 
08/P08       ASTM  E596 
08/P10       ANSI  S12.31  (ISO  3741) 
08/P24       ANSI  S 1 2. 1 0  (ISO  7779) 

08/P35       ASTM  El 050  „___ 

NVLAP  LAB  CODE  100288-0 
Bentley  Testing  Laboratory 
14641  E.  Don  Julian  Road 
P.O.  Box  527 

City  of  Industry,  CA  9 1 746-3 1 06 
Contact:  Ms.  Sandy  Kolby 
Phone:  626-333-4585  x2253 
Fax:  626-333-4125 

E-Mail:  Sandy_Kolby@mail.ifsia.com 

Carpet  and  Carpet  Cushion 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

Tests  Applicable  to  Carpet  Cushion 

03/U01a     ASTM  D3574  (Sec.  8.2  &  Test  A) 

03/U02       ASTM  D297 

03/U07       ASTM  D3574  (Test  C) 

03/U08       ASTM  D3 574  (Test  D) 

03/U10       ASTMD3676  (Sec.l3) 

Tests  Applicable  to  Carpet  and  Carpet  Cushion 

03/TO 1       AATCC  1 6  (Option  E) 

03/T04       16  CFR  Part  1630  (FF-1-70) 

Tests  Applicable  to  Carpets 

03/G04       AATCC  165 

03/G05       ASTM  D418  (Sec.  8) 

03/G06       ASTM  D4 1 8  (Sec.  9) 


03/G07       ASTM  D4 1 8  (Sees.  10-11) 
03/G08       ASTM  D418  (Sec.  13) 
03/G09       ASTM  D1335 
03/G10       ASTM  D3936 
03/G12  ASTME648 
03/G13  ASTME662 

NVLAP  LAB  CODE  100290-0 
Akzo  Kashima  Ltd.,  Kashima  EMC  Site 

1  Oaza  Sunayama,  Hasaki,  Kashima-gun 

Ibaraki  314-02 

JAPAN 

Contact:  Mr.  Shuichi  Kobayashi 

Phone:  +81-479-40-1097 

Fax:  +81-479-46-1788 

E-Mail:  shuichi.kobayashi@nifty.ne.jp 

FCC  Test  Methods 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO  1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  100290-2 
Akzo  Kashima  Ltd.  Kakegawa  EMC  Test  Site 

322  Shimotaruki,  Kakegawa 
Shizuoka  436-0222 
JAPAN 

Contact:  Seiji  Matsuda 

Phone:  +81-837-24-8191 

Fax:  +81-537-24-8193 

E-Mail:  akzoemc2@sb3.so-net.or.jp 

FCC  Test  Methods 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO  1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  la      Conducted  Emissions,  Power  Lines,  450  KHz 


NVLAP  1999  DIRECTORY  -  Page  D19 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


to  30  MHz 
1 2/FO 1  b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  100290-3 
Akzo  Kashima  Ltd.,  Nagano  EMC  Test  Site 

3226  Yokokawa,  Tatsuno,  Kamina-gun 

Nagano  399-0511 

JAPAN 

Contact:  Yoshio  Kowase 

Phone:  +81-266-47-531  1 

Fax:  +81-266-47-5540 

E-Mail:  akzoemc3@sb3.so-net.or.jp 

FCC  Test  Methods 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/F0 1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  la      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  100290-4 
Akzo  Kashima  Ltd.,  Matsuda  EMC  Test  Site 

1283  Yadorigi,  Matsuda,  Ashigarakami-gun 

Kanagawa  258-0001 

JAPAN 

Contact:  Hideki  Hayashi 

Phone:  +81-465-89-2316 

Fax:  +81-465-89-2160 

E-Mail:  akzoemc5@sb3.so-net.or.jp 

FCC  Test  Methods 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 


Federal  Communications  Commission  (FCC)  Methods 
1 2/FO  1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/F0 1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  1  b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  100290-5 
Akzo  Kashima  Ltd.,  Tochigi  EMC  Test  Site 

870  Nakaawano,  Awano,  Kamitsuga-gun 

Tochigi  322-0306 

JAPAN 

Contact:  Kazuharu  Yanagisawa 

Phone:  +81-289-86-7121 

Fax:  +81-289-86-7126 

E-Mail:  akzoemc6@sb3.so-net.or.jp 

FCC  Test  Methods 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO  1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  la      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  1  b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  100296-0 
Chomerics  Test  Services  (CTS) 

77  Dragon  Court 

Woburn,  MA  01888-4014 

Contact:  Mr.  David  C.  Inman 

Phone:  781-935-4850 

Fax:  781-935-2758 

E-Mail:  mpack@chomerics.com 

URL:  http://www.chomericstest.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 


NVLAP  1999  DIRECTORY  -  Page  D20 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

12/F01a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
12/F01b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  100297-0 
Professional  Testing  Laboratory,  Inc. 

714  Glenwood  Place 
Dalton,  GA  30721 
Contact:  Mr.  Greg  Phillips 
Phone:  706-226-3283 
Fax:  706-226-6787 


Carpet  and  Carpet  Cushion 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Tests  Applicable  to  Carpet  Cushion 

03/U01a  ASTM  D3574  (Sec.  8.2  &  Test  A) 

03/U01b  ASTM  D3676  (Sees.  10-12) 

03/U02  ASTM  D297 

03/U03  ASTM  D629  (Sec.  10) 

03/U04  ASTM  D629  (Sees.  1 3-22) 

03/U05  ASTM  D629  (Sees.  23-27) 

03/U06  ASTM  D 1 667  (Suffix  B) 

03/U07  ASTM  D3574  (Test  C) 

03/U08  ASTM  D3574  (Test  D) 

03/U09  ASTM  D3574  (Test  E) 

03/U10  ASTMD3676  (Sec.l3) 

03/U1 1  ASTM  D3676  (Sec.  14) 

03/U12  ASTM  D3676  (Sec.  15) 

03/U1 3  ASTM  D3676  (Sec.  1 6) 

Tests  Applicable  to  Carpet  and  Carpet  Cushion 

03/T01  AATCC  16  (Option  E) 

03/T02  ASTM  D2646  (Sees.  16-24) 

03/T04  1 6  CFR  Part  1 630  (FF- 1  -70) 

Tests  Applicable  to  Carpets 

03/G01  AATCC  20 

03/G02  AATCC  20A 

03/G03  AATCC  134 

03/G04  AATCC  165 

03/G05  ASTM  D4 18  (Sec.  8) 

03/G06  ASTM  D4 18  (Sec.  9) 

03/G07  ASTM  D4 1 8  (Sees.  10-11) 

03/G08  ASTM  D41 8  (Sec.  13) 

03/G09  ASTM  D1335 

03/G10  ASTM  D3936 


03/G11 
03/G12 
03/G13 


ASTM  D5252 
ASTM  E648 
ASTM  E662 


NVLAP  LAB  CODE  100308-0 
Special  Testing  Laboratories,  Inc. 

21  Henry  Street 

P.O.  Box  200 

Bethel,  CT  06801-0200 

Contact:  Mr.  Richard  Speciale 

Phone:  203-743-7281 

Fax:  203-791-2451 


Construction  Materials  Testing 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 


Aggregates 

02/A03       ASTM  C29 


02/A04 
02/A06 
02/A07 
02/A09 
02/A10 
02/A11 
02/A12 
02/A15 
02/A15 
02/A44 
Concrete 
02/A01 
02/A02 
02/A41 
02/A43 
02/A45 
02/G01 
02/G02 


ASTM  C40 
ASTM  C88 
ASTM  CI  17 
ASTM  CI 27 
ASTM  CI 28 
ASTM  CI 31 
ASTMC136 
ASTM  D75 
ASTM  D75 
ASTM  C566 


ASTM  C39 
ASTM  C617 
ASTM  CI 92 
ASTM  CI 064 
ASTM  C42 

ASTM  C31/C172/C143/C138/C231 
ASTM  CI 73 
Road  and  Paving  Materials 
02/M25      ASTM  D2726 
Soil  and  Rock 
02/L02       ASTM  D422 
02/L04       ASTM  D698 
02/L06       ASTM  D 1140 
02/L07       ASTM  D 1556 
02/L08       ASTM  D 1557 
02/L09       ASTM  D1558 
02/L12       ASTM  D2 168 
02/L13       ASTM  D2216 
02/L16       ASTM  D2487 
02/L17       ASTM  D2488 
02/L20       ASTM  D4318 
02/L23       ASTM  D2922 
02/L25       ASTM  D3017 
02/L31       ASTM  D2 167 
Standard  Practices 
02/A38       ASTM  E329 
02/A39       ASTM  CI 077 
Steel  Materials 

02/S02       ASTM  A3  70  (Sec.  1 4)/E  1 90 


NVLAP  1999  DIRECTORY  -  Page  D21 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


02/S07  ASTM  E709 
02/S08       ASTM  El 65 

NVLAP  LAB  CODE  100315-0 
Eastern  Materials  Testing  Lab  a  division  of 
Jaworski  Geotech 

One  Hartford  Square  #19 
New  Britain,  CT  06052 
Contact:  Mr.  Kevin  J.  Brigandi 
Phone:  860-224-3316 
Fax:  860-229-9567 
E-Mail:  emtl@connix.com 
URL:  http://www.jgi-geo.com 

Construction  Materials  Testing 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 
Aggregates 

02/A03  ASTM  C29 

02/A04  ASTM  C40 

02/A06  ASTM  C88 

02/A07  ASTM  CI  17 

02/A09  ASTM  CI 27 

02/A10  ASTM  CI 28 

02/A12  ASTM  CI 36 
Cement 

02/A17  ASTM  CI 09 

02/A30  ASTM  C266 
Concrete 

02/A01  ASTMC39 

02/A02  ASTM  C6 17 

02/A41  ASTM  CI 92 

02/A43  ASTM  CI 064 

02/A45  ASTM  C42 

02/G01  ASTM  C31/C172/C143/C138/C231 

02/G02  ASTM  CI 73 

Soil  and  Rock 

02/L02  ASTM  D422 

02/L04  ASTM  D698 

02/L06  ASTM  Dl  140 

02/L08  ASTM  D1557 

02/L12  ASTM  D2 168 

02/L13  ASTM  D2216 

02/L16  ASTM  D2487 

02/L20  ASTM  D4318 

02/L23  ASTM  D2922 

02/L25  ASTMD3017 

02/L31  ASTM  D2 167 

Standard  Practices 

02/A38  ASTM  E329 

02/A39  ASTM  CI 077 


NVLAP  LAB  CODE  100316-0 
Independent  Materials  Testing  Laboratories,  Inc. 

57  N.  Washington  Street 
P.O.Box  745 
Plainville,  CT  06062-0745 
Contact:  Mr.  David  P.  Aiudi 
Phone:  203-525-7193 
Fax:  203-747-6455 


Construction  Materials  Testing 

Accreditation  Valid  Through:  March  31,  1999 
NVLAP 

Code  Designation 
Aggregates 

02/A03  ASTM  C29 

02/A04  ASTM  C40 

02/A06  ASTM  C88 

02/A07  ASTM  CI  17 

02/A08  ASTM  CI 23 

02/A09  ASTM  CI 27 

02/A10  ASTM  CI 28 

02/A11  ASTM  CI 31 

02/A12  ASTM  CI 36 

02/A13  ASTM  CI 42 

02/A15  ASTMD75 

02/A44  ASTM  C566 

02/A46  ASTM  C535 
Cement 

02/A26  ASTM  CI 91 

02/A31  ASTMC305 
Concrete 

02/A01  ASTMC39 

02/A02  ASTM  C6 17 

02/A40  ASTM  C78 

02/A41  ASTM  CI 92 

02/A43  ASTM  CI 064 

02/A45  ASTM  C42 

02/G0 1  ASTM  C3 1  /CI  72/C 143/C1 3 8/C23 1 

02/G02  ASTM  CI 73 

Geotextiles 

02/L28  ASTM  D4354 
Road  and  Paving  Materials 

02/M08  ASTM  D979 

02/M11  ASTM  Dl  188 

02/M19  ASTM  D2 172 

02/M24  ASTM  D2041 

02/M25  ASTM  D2726 
Soil  and  Rock 

02/L01  ASTM  D4220 

02/L02  ASTM  D422 

02/L04  ASTM  D698 

02/L05  ASTM  D854 

02/L06  ASTM  Dl  140 

02/L07  ASTM  D 1556 

02/L08  ASTM  D1557 

02/L10  ASTM  D 1883 

02/L11  ASTM  D2 166 

02/L12  ASTM  D2 168 


NVLAP  1999  DIRECTORY  -  Page  D22 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


02/L13 

ASTM  D2216 

Aggregates 

02/L14 

ASTMD2217 

02/A04 

ASTM  C40 

02/L16 

ASTM  D2487 

02/A07 

ASTM  CI  17 

02/L17 

ASTM  D2488 

02/A09 

ASTM  CI 27 

02/L20 

ASTMD4318 

02/A10 

ASTM  CI 28 

02/L21 

ASTM  D2434 

02/A1 1 

ASTM  CI 31 

02/L24 

ASTM  D2974 

02/A12 

ASTM  CI 36 

02/L25 

ASTM  D3017 

02/A44 

ASTM  C566 

02/L29 

Corps  or  Engineers  -  Manual 

Concrete 

EM-1 1 10-2-1906,  Appendix  VII,  Permeability 

02/A01 

ASTM  C39 

of  Fine  Grained  Soils  Using  a  Triaxial 

02/A43 

ASTM  CI 064 

Apparatus 

02/G01 

ASTM  C31/C1 

Standard  Practices 

02/G02 

ASTM  CI 73 

02/A38 

ASTM  E329 

Soil  and  Rock 

02/A39 

ASTM  CI 077 

02/L04 

ASTM  D698 

5ree/  Materials 

02/L05 

ASTM  D854 

02/S07 

ASTM  E709 

02/L06 

ASTM  D 1140 

02/S08 

ASTM  El 65 

02/L07 
02/L08 

ASTM  D1556 
ASTM  D1557 

NVLAP  LAB  CODE  100317-0 

02/L12 

ASTM  D2 168 

Fairfield  Testing  Laboratory,  Inc. 

02/L23 

ASTM  D2922 

652  Glenbrook  Road,  P.O.  2310 

02/L25 

ASTM  D3017 

Stamford, 

CT  06906 

Standard  Practices 

Contact:  Mr.  James  E.  Quill 

02/A38 

ASTM  E329 

Phone:  203-372-1980 

02/ A3  9 

ASTM  CI 077 

Fax:  203-372-1898 
E-Mail:  JQuill@aol.com 

Construction  Materials  Testing 

Accreditation  Valid  Through:  March  31 
NVLAP 

Code  Designation 
Aggregates 

02/A12  ASTM  CI 36 
Concrete 
02/A01 
02/A02 
02/A43 
02/G01 
02/G02 


1999 


ASTM  C39 
ASTM  C6 17 
ASTM  CI 064 

ASTM  C31/C172/C143/C138/C231 
ASTM  CI 73 
Soil  and  Rock 
02/L08       ASTM  D1557 
02/L23       ASTM  D2922 
02/L25       ASTM  D3017 


NVLAP  LAB  CODE  100319-0 


PSI,  Inc. 

55  State  Street 
North  Haven,  CT  06473 
Contact:  Mr.  Ted  Swenson 
Phone:  203-239-3353 
Fax:  203-239-3453 


Construction  Materials  Testing 

Accreditation  Valid  Through:  March  31, 
NVLAP 

Code  Designation 


1999 


NVLAP  LAB  CODE  100320-0 
Materials  Testing,  Inc. 

200  Rowe  Avenue 
Milford,  CT  06460 
Contact:  Mr.  Frank  A.  Soucy 
Phone:  203-878-2765 
Fax:  208-878-1504 


Construction  Materials  Testing 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 


Aggregates 

02/A03 
02/A04 
02/A06 
02/A07 
02/A08 
02/A09 
02/A10 
02/A11 
02/A12 
Cement 
02/A17 
Concrete 
02/A01 
02/A02 
02/G01 
02/G02 


ASTM  C29 
ASTM  C40 
ASTM  C88 
ASTM  CI  17 
ASTM  CI 23 
ASTM  CI 27 
ASTM  CI 28 
ASTM  C131 
ASTMC136 

ASTM  CI 09 


ASTM  C39 
ASTM  C617 

ASTM  C3 1  /C 1 72/C 1 43/C 1 3  8/C23 1 
ASTM  CI 73 
Soil  and  Rock 
02/L02       ASTM  D422 
02/L04       ASTM  D698 
02/L05       ASTM  D854 


NVLAP  1999  DIRECTORY  -  Page  D23 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


02/L06  ASTMD1140 

02/L08  ASTMD1557 

02/L13  ASTM  D2216 

02/L23  ASTM  D2922 

02/L31  ASTM  D2 167  

NVLAP  LAB  CODE  100322-0 
Canadian  Standards  Association 

178  Rexdale  Boulevard 
Etobicoke  Ontario  M9W  1R3 
CANADA 

Contact:  Mr.  Doug  Geralde 
Phone:  416-747-4295 
Fax:  416-747-4287 
E-Mail:  geralded@csa.ca 

Commercial  Products  Testing 

Accreditation  Valid  Through:  March  31,  1999 
NVLAP 

Code  Designation 
Plumbing 

19/F01  ASME  A112.18.1M  (Sec.  5.2) 

19/F02  ASME  Al  12.18. 1M  (Sec.  5.14) 

19/F03  ASME  A112.18.1M  (Sec.  6.2) 

19/F04  ASME  Al  12.18. 1M  (Sec.  6.4) 

19/F05  ASME  A112.18.1M  (Sec.  6.5) 

19/F06  ASME  A112.18.1M  (Sec.  6.6) 

19/F07  ASME  All  2.18. 1M  (Sec.  6.7) 

19/F08  ASME  A112.18.1M  (Sec.  6.8) 

19/F09  ASME  Al  12.18. 1M  (Sec.  5.13) 

19/F10  ASME  Al  12. 18. 1M  (Sec.  6.3) 

19/M01  ANSI/CABOA1 17.1  (Sec.  4.24) 

19/M02  ASME/ANSI  Al  12.19. 7M  (Sec.  5,  7) 

19/M03  ASME/ANSI  Al  12.19. 8M  (Sec.  4,  5) 

19/M04  ASTMF446 

19/P01  ANSI  Z124.1  (Sec.  4,  5,  6) 

19/P02  ANSI  Z124.2  (Sec.  4,  5,6) 

19/P03  ANSI  Z124.3  (Sec.  4,  5,6) 

19/P04  ANSI  Z  124.4  (Sec.  4,  5) 

19/P05  ANSI  Z124.4  (Sec.  8)  per  ASME  Al  12.19.6M 
(Sec.  7.1) 

19/P06  ANSI/IAPMO  Z  124.6  (Sec.  4,  5,  6) 

19/P07  ANSI/IAPMO  Z124.8  (Sec.  4,  5) 

19/U01  ASME/ANSI  Al  12.18. 3M  (Sec.  5.1,  12.1, 

12.2,  13,  14,  16) 

19/V01  ASME  A112.19.2M  (Sec.  7.1) 

19/V02  ASME  A112.19.2M  (Sec.  7.2) 

19/V03  ASME  Al  12.19.2M  (Sec.  7.3) 

19/V04  ASME  All  2.19. 2M  (Sec.  7.4) 

19/V05  ASME  Al  12.19. 2M  (Sec.  7.5) 

19/V06  ASME  Al  12.19. 2M  (Sec.  7.7) 

19/W01  ASME  Al  12.19.6  (Sec.  7.1.2) 

19/W02  ASME  Al  12. 19.6  (Sec.  7.1.3) 

19/W03  ASME  Al  12.19.6  (Sec.  7.1.4) 

19/W04  ASME  Al  12.19.6  (Sec.  7.1.5) 

19/W05  ASME  Al  12.19.6  (Sec.  7.1.6) 

19/W06  ASME  Al  12.19.6  (Sec.  7.1.7) 

19/W07  ASME  Al  12.19.6  (Sec.  7.1.8) 

19/W08  ASME  Al  12.19.6  (Sec.  7.1.9) 


FCC  Test  Methods 

Accreditation  Valid  Through:  March  31,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 

1 2/FO 1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 

Devices 

1 2/FO  1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR22T993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  100323-0 
IBM  Hudson  Valley  Acoustics  Laboratory 

Building  704,  M/S  P226 
522  South  Road 
Poughkeepsie,  NY  12601  -5400 
Contact:  Dr.  Matthew  A.  Nobile 
Phone: 914-435-4959 
Fax: 914-432-9880 
E-Mail:  nobile@us.ibm.com 

Acoustical  Testing  Services 

Accreditation  Valid  Through:  March  31,  1999 

NVLAP 

Code  Designation 

08/P03       ASTM  C423  (ISO  354) 
08/P10       ANSI  S12.31  (ISO  3741) 
08/P13       ANSI  S12.32  (ISO  3742) 
08/P21        ISO  3745 
08/P24       ANSI  S 1 2. 1 0  (ISO  7779) 
08/P38  ANSIS12.il 

08/P39       ANSI  S 1 2.5  (ISO  6926)  

NVLAP  LAB  CODE  100325-0 
City  of  San  Jose,  Materials  Testing  Laboratory 

696  North  6th  Street,  Building  200 
San  Jose,  CA  951  12-3208 
Contact:  Mr.  Alberto  C.  Oxonian 
Phone:  408-277-4513 
Fax:  408-275-8090 


Construction  Materials  Testing 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 
Aggregates 

02/A03  ASTM  C29 
02/A04       ASTM  C40 


NVLAP  1999  DIRECTORY  -  Page  D24 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


02/A06 

ASTM  C88 

INVLAr  LAB  L.UDL  lUUjJy-U 

02/A07 

ASTMC117 

Data  General  Corporation 

02/A09 

ASTM  CI 27 

02/A10 

ASTM  CI 28 

4400  Computer  Drive 

02/A11 

ASTMC131 

Westboro,  MA  01580 

02/A12 

ASTM  CI 36 

Contact:  Mr.  Joseph  DeMonaco 

02/A13 

ASTM  CI 42 

Phone:  508-898-6051 

02/A15 

ASTM  D75 

Fax:  508-898-5413 

02/A16 

ASTMD2419 

E-Mail:  Joe  Demonaco@dg.com 

02/A44 

ASTM  C566 

Cement 

FCC  Test  Methods 

02/A17 

ASTM  CI 09 

Accreditation  Valid  Through:  December  31,  1999 

02/A22 

ASTM  CI  83 

NVLAP 

02/A52 

ASTM  C1019 

Code  Designation 

Concrete 

02/A01 

ASTM  C39 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 

02/A02 

ASTM  C6 17 

Technical  Standards 

02/A40 

ASTM  C78 

12/T51       AS/NZS  3548 

02/A41 

ASTM  CI 92 

Federal  Communications  Commission  (FCC)  Methods 

02/A42 

ASTM  C360 

1 2/FO 1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 

02/A43 

ASTM  CI 064 

Devices 

02/A45 

ASTM  C42 

1 2/FO  la      Conducted  Emissions,  Power  Lines,  450  KHz 

02/G01 

ASTM  C3 1 IC 1 72/C 143/C13 8/C23 1 

to  30  MHz 

02/G02 

ASTM  CI 73 

1 2/FO  lb      Radiated  Emissions 

Road  and  Paving  Materials 

International  Special  Committee  on  Radio  Interference 

02/M01 

ASTM  D5 

(CISPR)  Methods 

02/M03 

ASTM  D 140 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 

02/M05 

ASTM  D244 

mPFKiirpmpnt  of  radio  Hi^tnrhancp 

1  1  IvUO  III  V  1  1  IV 1  11    V  '  I     1  1.4  V.4  IV'    U  1  .ii  L)  1  1  Ml  K 

02/M07 

ASTMD546 

characteristics  of  information  technology 

02/M08 

ASTMD979 

02/M09 

ASTM  D 1074 

equipment 

02/M11 

ASTM  Dl  188 

NVLAP  LAB  CODE  100340-0 

02/M12 

ASTM  Dl 559 

Fairway  Testing  Company,  Inc. 

02/M13 

ASTM  D 1560 

Smith  Street 

02/M14 

ASTM  D 1561 

P.O.  Box  578 

02/M15 

ASTM  D 1856 

Stony  Point,  NY  10980 

02/M17 

ASTM  D2 170 

Contact:  Mr.  Patsy  J.  Aguanno 

02/M18 

ASTM  D2 1 7 1 

Phone:  914-942-2088 

02/M19 

ASTM  D2 172 

Pqv  Q1A  QA7  flOOS 

02/M20 

ASTM  D2872 

02/M24 

ASTM  D2041 

02/M25 

ASTM  D2726 

Construction  Materials  Testing 

02/L02 

ASTM  D422 

Accreditation  Valid  Through:  September  30,  1999 

02/L05 

ASTM  D854 

NVLAP 

02/L06 

ASTM  D 1140 

02/L08 

ASTM  Dl 557 

Aggregates 

02/A03       ASTM  C29 

02/L12 

ASTM  D2168 

02/L13 

ASTM  D2216 

02/A04       ASTM  C40 

02/L14 

ASTMD2217 

02/A06       ASTM  C88 

02/L16 

ASTM  D2487 

02/A07       ASTM  CI  17 

02/L20 

ASTMD4318 

02/A08       ASTM  CI 23 

02/L23 

ASTM  D2922 

02/A09       ASTM  CI 27 

02/L25 

ASTM  D3017 

02/A10       ASTM  CI 28 

02/L47 

ASTM  D2844 

02/A12       ASTM  CI 36 

Standard  Practices 

02/A13       ASTM  CI 42 

02/A38 

ASTM  E329 

02/A15  ASTMD75 

02/A39 

ASTM  CI 077 

02/A16       ASTM  D2419 

02/L32 

ASTM  D3740 

02/A44       ASTM  C566 

02/M26 

ASTM  D3666 

NVLAP  1999  DIRECTORY  -  Page  D25 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Concrete 

02/A01       ASTM  C39 

02/A02       ASTM  C6 17 

02/A40       ASTM  C78 

02/A41        ASTM  CI 92 

02/A43       ASTM  CI 064 

02/G01       ASTM  C31/C172/C143/C138/C231 

02/G02       ASTM  CI 73 

Road  and  Paving  Materials 

02/M01       ASTM  D5 

02/M07      ASTM  D546 

02/M08      ASTM  D979 

02/M11       ASTM  Dl  188 

02/M12      ASTM  D 1559 

02/M15      ASTM  D 1856 

02/M19       ASTM  D2 172 

02/M24      ASTM  D2041 

02/M25      ASTM  D2726 

Soil  and  Rock 

02/L01       ASTM  D4220 

02/L02       ASTM  D422 

02/L04       ASTM  D698 

02/L05       ASTM  D854 

02/L06       ASTM  Dl  140 

02/L07       ASTM  D 1556 

02/L08       ASTM  D 1557 

02/L13  ASTMD2216 

02/L16       ASTM  D2487 

02/L17       ASTM  D2488 

02/L20       ASTM  D4318 

02/L21       ASTM  D2434 

02/L23       ASTM  D2922 

02/L25       ASTM  D3017 

02/L29       Corps  of  Engineers  -  Manual 

EM-1 1 10-2-1906,  Appendix  VII,  Permeability 
of  Fine  Grained  Soils  Using  a  Triaxial 
Apparatus 

Standard  Practices 

02/A38       ASTM  E329 

02/A39       ASTM  CI 077 

02/L32       ASTM  D3740 

02/M26      ASTM  D3666 

Steel  Materials 

02/S02       ASTM  A370  (Sec.  14VE190 
02/S07       ASTM  E709 
02/S08       ASTM  El 65 

NVLAP  LAB  CODE  100347-0 
Acton  Environmental  Testing,  dba  National 
Technical  Systems 

1 146  Massachusetts  Avenue 
Boxborough,  MA  01719 
Contact:  Mr.  James  Press 
Phone:  978-266-1001 
Fax:  978-266-1073 


MIL-STD-462  Test  Methods 

Accreditation  Valid  Through:  March  31 
NVLAP 

Code  Designation 


1999 


Conducted  Emissions: 

12/A01       M'L-STD-462  Method  CE01 

1 2/A04       MIL-STD-462  Method  CE02 

1 2/A06       MIL-STD-462  Method  CE03 

1 2/A08       MIL-STD-462  Method  CE04 

12/A12       MIL-STD-462  Method  CE07 

Conducted  Susceptibility: 

12/B01       MIL-STD-462  Method  CS01 

12/B02       MIL-STD-462  Method  CS02 

1 2/B05       MIL-STD-462  Method  CS06 

1 2/B07       MIL-STD-462  Method  CS09 

Radiated  Emissions: 

12/D01       MIL-STD-462  Method  RE01 

1 2/D02       MIL-STD-462  Method  RE02 

Radiated  Susceptibility: 

1 2/EO 1       MIL-STD-462  Method  RS0 1 

1 2/E02       MIL-STD-462  Method  RS02 

1 2/E03       M I L-STD-462  Method  RS03  (Consult 

laboratory  for  field  strengths  available) 
12/E04       MIL-STD-462  Method  RS03  employing 

RADHAZ  procedures  for  high  level  testing 

(Consult  laboratory  for  field  strengths 

available) 

1 2/E07       MIL-STD-462  Method  RS06 

NVLAP  LAB  CODE  100350-0 
Northern  Telecom  Product  Integrity  Labs. 

21  Richardson  Side  Road 
Kanata  Ontario  K2K  2C1 
CANADA 

Contact:  Mr.  Rick  McDonald 
Phone:  613-763-2475 
Fax:  613-763-8091 
E-Mail:  McD^nortel.ca 

FCC  Test  Methods 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51        AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 

1 2/F0 1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

12/F01a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
12/F01b      Radiated  Emissions 
12/T01       Terminal  Equipment  Network  Protection 

Standards,  FCC  Method  -  47  CFR  Part  68  - 

Analog  and  Digital 
12/T01a      68.302  (Par.  c,d,e,f)  Environmental  simulation; 

68.304  Leakage  current  limit.;  68.306 

Hazardous  voltage  limit.;  68.308  Signal  power 


NVLAP  1999  DIRECTORY  -  Page  D26 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


limit.;  68.310  Longitudinal  balance  limit.; 
68.312  On-hook  impedance  limit.;  68.314 
Billing  protection 
12/TOlb     68.316  Hearing  Aid  Compatibility:  technical 
standards 

12/TOlc      68.302  Environmental  simulation  (Par.  a,b) 
International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  100351-0 

KTL  Ottawa  Inc. 

3325  River  Road,  R.R.  No.  5 
Ottawa  Ontario  K1V  1H2 
CANADA 

Contact:  Mr.  Marc  Beisheim 

Phone:  613-737-9680 

Fax:  613-737-9691 

E-Mail:  KTL@KTLCanada.com 

URL:  http://www.ktl.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

AUSTEL  Technical  Standards  as  determined  under  the 

Telecommunications  Act  of  1991 

12/T41  TS-001 

12/T42  TS-002 

12/T43  TS-003 

12/T44  TS-004 

12/T45  TS-006 

12/T46  TS-008 

12/T49  TS-016 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
12/F01       FCC  Method  -  47  CFR  Part  15  -  Digital 
Devices 

12/F01a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
12/F01b      Radiated  Emissions 
12/T01       Terminal  Equipment  Network  Protection 

Standards,  FCC  Method  -  47  CFR  Part  68  - 

Analog  and  Digital 
12/T01a     68.302  (Par.  c,d,e,f)  Environmental  simulation; 

68.304  Leakage  current  limit.;  68.306 

Hazardous  voltage  limit.;  68.308  Signal  power 

limit.;  68.310  Longitudinal  balance  limit.; 

68.312  On-hook  impedance  limit.;  68.314 

Billing  protection 
12/TOlb     68.316  Hearing  Aid  Compatibility:  technical 

standards 

12/TOlc      68.302  Environmental  simulation  (Par.  a,b) 


International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  100354-0 
Control  Data  Accredited  OSI  Test  Center 

4201  Lexington  Avenue  North 

Arden  Hills,  MN  55126-6198 

Contact:  Mr.  Ronald  D.  Swan 

Phone:  612-415-4659 

Fax:  612-415-3879 

E-Mail:  Ronald.D.Swan@cdc.com 

GOSIP 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

17/G03       ITU  X.400-1984  MHS:  P2/Pl/RTS/(Session) 
17/G21       ITU  X.400-1988  MHS 
17/G21a     ITU  X.400-1988  MHS: 

P2/Pl/RTSE/ACSE/Presentation  (Session) 
17/G23       ITU-T  X.500-1988  DS:  Directory 

Services-Directory  Access  Protocol 

NVLAP  LAB  CODE  100357-0 
National  Computing  Centre  Ltd. 
Oxford  Road 
Manchester,  M17ED 
UNITED  KINGDOM 
Contact:  Mrs.  A.  E.  J.  Pink 
Phone:  +44  1  61  242-2257 
Fax:  +44  1  61  236-9877 
E-Mail:  jane@ncc.co.uk 

GOSIP 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

17/G01       ISO/IEC  8571/8650/8823: 

FTAM/ACSE/Presentation  (Session) 
17/G03       ITU  X.400-1984  MHS:  P2/Pl/RTS/(Session) 
I7/G05       ISO/IEC  8327:  Session 
1 7/G07       ISO/IEC  8073 :  Transport  Class  4 
1 7/G09       ISO/IEC  8073 :  Transport  Class  2/Transport 
Class  0 

17/G11 

17/G1  la     ISO/IEC  8473:  Connectionless  Network 

Protocol  (CLNP) 
1 7/G 1 1  b     ISO/IEC  9542:  End  System-Intermediate 

System  (ES-IS) 
17/G19       ITU  X.25:  PLP/HDLC  LAP  B 
17/G21       ITU  X.400-1988  MHS 
17/G21a     ITU  X.400-1988  MHS: 

P2/Pl/RTSE/ACSE/Presentation  (Session) 
17/G21b     ITU  X.400-1988  MHS:  P3 
17/G21c     ITU  X.400-1988  MHS:  P3/ROSE 


NVLAP  1999  DIRECTORY  -  Page  D27 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


17/G21d     ITU  X.400-1988  MHS:  P7 
17/G21c     ITU  X.400-1988  MHS:  P7/ROSE 
17/G23       ITU-T  X.500- 1988  DS:  Directory 
Services-Directory  Access  Protocol 

NVLAP  LAB  CODE  100374-0 
Aearo  Company,  EA-RCAL  Acoustical 
Laboratory 

791 1  Zionsville  Road 

Indianapolis,  IN  46268-1657 

Contact:  Mr.  Elliott  H.  Berger 

Phone:  317-692-3031 

Fax:  317-692-3116 

E-Mail:  eberger@compuserve.com 

URL:  http://www.e-a-r.com 

Acoustical  Testing  Services 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

08/P26       ANSI  S3. 19  (ANSI  S3. 19-1974) 
08/P27       ANSI  SI 2. 6 

NVLAP  LAB  COOK  100382-0 

Eaton  E3  Laboratory 

26201  Northwestern  Highway 
P.O.  Box  766 

Southfield,  MI  48037-0766 

Contact:  Mr.  Kimball  Williams 

Phone:  248-354-2845 

Fax:  248-208-2018 

E-Mail:  k.williams@ieee.org 

MIL-STD-462  Test  Methods 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Conducted  Emissions: 

1 2/A0 1       MIL-STD-462  Method  CEO  1 

1 2/A04       MIL-STD-462  Method  CE02 

1 2/A06       MIL-STD-462  Method  CE03 

12/A08       MIL-STD-462  Method  CE04 

12/A12       MIL-STD-462  Method  CE07 

Conducted  Susceptibility: 

1 2/B0 1       MIL-STD-462  Method  CSO 1 

1 2/B02       MIL-STD-462  Method  CS02 

1 2/B05       MIL-STD-462  Method  CS06 

12/B07       MIL-STD-462  Method  CS09 

Radiated  Emissions: 

1 2/DO 1       MIL-STD-462  Method  RE0 1 

1 2/D02       MIL-STD-462  Method  RE02 

Radiated  Susceptibility: 

12/E01       MIL-STD-462  Method  RS01 

1 2/E02       MIL-STD-462  Method  RS02 

1 2/E03       MIL-STD-462  Method  RS03  (Consult 

laboratory  for  field  strengths  available) 
12/E04       MIL-STD-462  Method  RS03  employing 

RADHAZ  procedures  for  high  level  testing 

(Consult  laboratory  for  field  strengths 

available) 


12/E07       MIL-STD-462  Method  RS06 

NVLAP  LAB  CODE  100396-0 

Criterion  Technology 

1350  County  Road  #16 

P.O.  Box  387 

Rollinsville,  CO  80474 

Contact:  Mr.  R.  Barry  Wallen 

Phone:  303-682-6600 

Fax:  303-682-6672 

E-Mail:  b.wallen@criteriontech.com 

URL:  www.criteriontech.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  March  31,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 

1 2/F0 1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 

Devices 

12/F01a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO 1  b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  100398-0 
GE  Lighting-  Engineering  Support  -  NA 

1975  Noble  Road 
Nela  Park 

Cleveland,  OH  44112-6300 
Contact:  Mr.  Arthur  H.  Lupfer 
Phone: 216-266-2365 
Fax:  216-266-6986 

E-Mail:  Arthur.Lupfer@lighting.ge.com 

Energy  Efficient  Lighting  Products 

Accreditation  Valid  Through:  March  31,  1999 
NVLAP 

Code  Designation 

Color  Measurements 

22/C01       IES  LM-58 
Electrical  Measurements 
22/E01  IESLM-9 
22/E02       IES  LM-45 
22/E03       IES  LM-5 1 
22/E04       IES  LM-66 
22/E05  ANSI-C78.375 
Life  Tests 

22/L01  IESLM-40 
22/L03  IES  LM-49 
22/L04       IES  LM-65 


NVLAP  1999  DIRECTORY  -  Page  D28 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Photometric  Measurements 

22/PO 1  a  IES  LM-9  (Total  Flux) 

22/PO lb  IES  LM-9  (Intensity) 

22/P02a  EES  LM-20  (Total  Flux) 

22/P02b  IES  LM-20  (Intensity) 

22/P03a  IES  LM-45  (Total  Flux) 

22/P03b  IES  LM-45  (Intensity) 

22/P04a  IES  LM-5 1  (Total  Flux) 

22/P05a  IES  LM-66  (Total  Flux) 

22/P05b  IES  LM-66  (Intensity) 


Color  Measurements 
22/C01       IES  LM-5 8 
Electrical  Measurements 


NVLAP  LAB  CODE  100399-0 
Philips  Lighting  Corporate  Calibration  & 
Standards  Laboratory 

Route  3,  P.O.  Box  505,  Hoult  Road 
Fairmont,  WV  26554-9484 
Contact:  Dr.  Ronald  Gibbons 
Phone:  304-367-7608 
Fax:  304-367-7602 

E-Mail:  jltfccsl@ussmlt61.snads.philips.nl 

Energy  Efficient  Lighting  Products 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 


Color  Measurements 
22/C01       IES  LM-5 8 
Electrical  Measurements 


IES  LM-9 
IES  LM-45 
IES  LM-5 1 
IES  LM-66 
ANSI-C78.375 
ANSI-C78.386 
ANSI-C78.387 
ANSI-C78.388 
Photometric  Measurements 
22/P01a      IES  LM-9  (Total  Flux) 
IES  LM-20  (Total  Flux) 
IES  LM-20  (Intensity) 
IES  LM-45  (Total  Flux) 
IES  LM-45  (Intensity) 
IES  LM-51  (Total  Flux) 
IES  LM-66  (Total  Flux) 


22/E01 
22/E02 
22/E03 
22/E04 
22/E05 
22/E06 
22/E07 
22/E08 


22/P02a 
22/P02b 
22/P03a 
22/P03b 
22/P04a 
22/P05a 


NVLAP  LAB  CODE  100402-0 
Intertek  Testing  Services  NA  Inc. 

3933  U.S.  Route  1 1 

Cortland,  NY  13045-0950 

Contact:  Mr.  Craig  Davenport 

Phone: 607-758-6296 

Fax:  607-756-9891 

E-Mail:  cdavenport@itsqs.com 

URL:  http://www.worldlab.com 

Energy  Efficient  Lighting  Products 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 


22/E01 

22/E02 

22/E03 

22/E04 

22/E05 

22/E06 

22/E07 

22/E08 

Life  Tests 

22/L03 


IES  LM-9 
IES  LM-45 
IES  LM-5 1 
IES  LM-66 
ANSI-C78.375 
ANSI-C78.386 
ANSI-C78.387 
ANSI-C78.388 

IES  LM-49 


Photometric  Measurements 

22/PO  1  a      IES  LM-9  (Total  Flux) 

22/P02a      IES  LM-20  (Total  Flux) 

22/P03a      IES  LM-45  (Total  Flux) 

22/P03b      IES  LM-45  (Intensity) 

22/P04a      IES  LM-5 1  (Total  Flux) 

22/P05a      IES  LM-66  (Total  Flux) 

22/P05b      IES  LM-66  (Intensity) 

Thermal  Insulation  Materials 

Accreditation  Valid  Through:  September  30,  1999 

NVLAP 

Code  Designation 

Flammability 

01/F02  ASTME84 
Thermal  Resistance 

01/T06  ASTMC518 

NVLAP  LAB  CODE  100403-0 
Osram  Sylvania  Inc.,  Test  &  Measurements 
Laboratory 

71  Cherry  Hill  Dr. 

Beverly,  MA  01915 

Contact:  Dr.  Ronald  O.  Daubach 

Phone:  508-750-1593 

Fax:  508-750-1794 

E-Mail:  daubach@osi.sylvania.com 

Energy  Efficient  Lighting  Products 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Color  Measurements 
22/C01       IES  LM-5 8 
Electrical  Measurements 


22/E01 

22/E02 

22/E03 

22/E04 

22/E05 

22/E06 

22/E07 

22/E08 

Life  Tests 

22/L01 

22/L02 

22/L03 


IES  LM-9 
IES  LM-45 
IES  LM-51 
IES  LM-66 
ANSI-C78.375 
ANSI-C78.386 
ANSI-C78.387 
ANSI-C78.388 

IES  LM-40 
IES  LM-47 
IES  LM-49 


NVLAP  1999  DIRECTORY  -  Page  D29 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


22/L04  IES  LM-65 

Photometric  Measurements 

22/P01a  IES  LM-9  (Total  Flux) 

22/PO 1  b  IES  LM-9  (Intensity) 

22/P02a  IES  LM-20  (Total  Flux) 

22/P02b  IES  LM-20  (Intensity) 

22/P03a  IES  LM-45  (Total  Flux) 

22/P03b  IES  LM-45  (Intensity) 

22/P04a  IES  LM-5 1  (Total  Flux) 

22/P04b  IES  LM-51  (Intensity) 

22/P05a  IES  LM-66  (Total  Flux) 

22/PQ5b  IES  LM-66  (Intensity)  

NVLAP  LAB  CODE  100404-0 
Industrial  Acoustics  Company,  Inc., 
Aero-Acoustics  Laboratory 

1 1 60  Commerce  Avenue 
Bronx,  NY  10462 
Contact:  Mr.  Jon  Weinstein 
Phone:  718-931-8000 
Fax:  718-863-1 138 


Acoustical  Testing  Services 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

08/P02       ASTM  C384 

08/P03       ASTM  C423  (ISO  354) 

08/P04  ASTMC522 

08/P06       ASTM  E90  (ISO  1 40,  Part  3 ) 

08/P08       ASTM  E596 

08/P30       ASTM  E1408 

08/P36       ASTM  E477 

NVLAP  LAB  CODE  100405-0 
Motorola  SSTG  EMC/TEMPEST  Laboratory 

8201  E.  McDowell  Road 

Scottsdale,  AZ  85252 

Contact:  Mr.  Dwayne  R.  Awerkamp 

Phone:  602-441-3138 

Fax:  602-441-3625 

E-Mail:  p09969@email.mot.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/F0 1  b      Radiated  Emissions 


International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22: 1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

MIL-STD-462  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 

NVLAP 

Code  Designation 

Conducted  Emissions: 

1 2/A0 1  MIL-STD-462  Method  CEO  1 
1 2/A04  MIL-STD-462  Method  CE02 
12/A06  MIL-STD-462  Method  CE03 
1 2/A08  MIL-STD-462  Method  CE04 
1 2/A 1 0  MIL-STD-462  Method  CE06 
12/A1 2  MIL-STD-462  Method  CE07 
Conducted  Susceptibility: 
1 2/B0 1  MIL-STD-462  Method  CS0 1 
1 2/B02  MIL-STD-462  Method  CS02 
12/B04       MIL-STD-462  Method 

CS03/CS04/CS05/CS08 
1 2/B05  MIL-STD-462  Method  CS06 
12/B06  MIL-STD-462  Method  CS07 
1 2/B07  MIL-STD-462  Method  CS09 
1 2/B08  MIL-STD-462  Method  CS 1 0 
1 2/B09  MIL-STD-462  Method  CS  1 1 
12/B10  MIL-STD-462  Method  CS  1 2 
1 2/B 1 1  MIL-STD-462  Method  CS  1 3 
Radiated  Emissions: 
1 2/DO 1  MIL-STD-462  Method  RE0 1 
1 2/D02  MIL-STD-462  Method  RE02 
1 2/D03  MIL-STD-462  Method  RE03 
Radiated  Susceptibility: 
1 2/E0 1  MIL-STD-462  Method  RS0 1 
1 2/E02  MIL-STD-462  Method  RS02 
1 2/E03       MIL-STD-462  Method  RS03  (Consult 

laboratory  for  field  strengths  available) 
12/E04       MIL-STD-462  Method  RS03  employing 

RADHAZ  procedures  for  high  level  testing 

(Consult  laboratory  for  field  strengths 

available) 

1 2/E05       MIL-STD-462  Method  RS05 

1 2/E07       MIL-STD-462  Method  RS06  

NVLAP  LAB  CODE  100406-0 
Inland  Foundation  Engineering,  Inc. 

1310  South  Santa  Fe  Avenue 
P.O.  Box  937 

San  Jacinto,  CA  92581-0937 
Contact:  Mr.  Donald  O.  Swenson 
Phone:  909-654-1555 
Fax:  909-654-0551 


NVLAP  1999  DIRECTORY  -  Page  D30 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Construction  Materials  Testing 

Accreditation  Valid  Through:  March  31,  1999 
NVLAP 

Code  Designation 
Aggregates 

02/A03  ASTM  C29 

02/A04  ASTM  C40 

02/A06  ASTM  C88 

02/A07  ASTM  CI  17 

02/A09  ASTM  CI 27 

02/A10  ASTM  CI 28 

02/A11  ASTM  CI 31 

02/A12  ASTM  CI 36 

02/A15  ASTMD75 

02/A16  ASTM  D2419 

02/A44  ASTM  C566 

02/A46  ASTM  C535 
Concrete 

02/A01  ASTM  C39 

02/A02  ASTM  C6 17 

02/A41  ASTM  CI 92 

02/A43  ASTM  CI 064 

02/A45  ASTM  C42 

02/G01  ASTM  C31/C172/C143/C138/C231 

Road  and  Paving  Materials 

02/M08  ASTM  D979 

02/M11  ASTM  Dl  188 

02/M13  ASTM  Dl 560 

02/M14  ASTM  D1561 

02/M25  ASTM  D2726 

Soil  and  Rock 

02/L01  ASTM  D4220 

02/L02  ASTM  D422 

02/L04  ASTM  D698 

02/L05  ASTM  D854 

02/L06  ASTM  D 1140 

02/L07  ASTM  Dl 556 

02/L08  ASTM  Dl 557 

02/L16  ASTM  D2487 

02/L18  ASTM  D3080 

02/L20  ASTMD4318 

02/L21  ASTM  D2434 

02/L23  ASTM  D2922 

02/L25  ASTM  D3017 

02/L47  ASTM  D2844 

Standard  Practices 

02/A38  ASTM  E329 

02/A39  ASTM  CI 077 

02/L32  ASTM  D3740 

02/M26  ASTM  D3666 


NVLAP  LAB  CODE  100408-0 
NAWC  AD  5.1.7.3.  EMI  Lab 

48298  Shaw  Road,  Unit  4,  Bldg.  1461 

Patuxent  River,  MD  20670- 1 900 

Contact:  Mr.  Robert  Smith 

Phone:  301-342-0851 

Fax:  301-342-5390 

E-Mail:  smithRB@navair.navy.mil 

MIL-STD-462  Test  Methods 

Accreditation  Valid  Through:  March  31,  1999 
NVLAP 

Code  Designation 

Conducted  Emissions: 

1 2/AO 1       MIL-STD-462  Method  CEO  1 

1 2/A04       MIL-STD-462  Method  CE02 

12/A06       MIL-STD-462  Method  CE03 

1 2/A08       MIL-STD-462  Method  CE04 

Conducted  Susceptibility: 

12/B01       MIL-STD-462  Method  CS01 

1 2/B02       MIL-STD-462  Method  CS02 

1 2/B05       MIL-STD-462  Method  CS06 

Radiated  Emissions: 

1 2/DO 1       MIL-STD-462  Method  RE0 1 

1 2/D02       MIL-STD-462  Method  RE02 

Radiated  Susceptibility: 

1 2/EO 1       MIL-STD-462  Method  RS0 1 

1 2/E02       MIL-STD-462  Method  RS02 

1 2/E03       MIL-STD-462  Method  RS03  (Consult 

laboratory  for  field  strengths  available) 
1 2/E04       MIL-STD-462  Method  RS03  employing 

RADHAZ  procedures  for  high  level  testing 

(Consult  laboratory  for  field  strengths 

available) 

NVLAP  LAB  CODE  100409-0 
Intertek  Testing  Services  NA  Inc. 

4317-A  Park  Drive  N.W. 
Norcross,  GA  30093-2968 
Contact:  Mr.  David  C.  Dennis 
Phone:  770-925-2444 
Fax:  770-925-7294 
E-Mail:  ddennis@itsqs.com 
URL:  http://www.worldlab.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

AUSTEL  Technical  Standards  as  determined  under  the 
Telecommunications  Act  of  1991 

12/T41  TS-001 
12/T42  TS-002 
12/T44  TS-004 
12/T45  TS-006 
12/T46  TS-008 
12/T49  TS-016 


NVLAP  1999  DIRECTORY  -  Page  D31 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T50  AS/NZS  3260 
12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  la      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 
12/T01       Terminal  Equipment  Network  Protection 

Standards,  FCC  Method  -  47  CFR  Part  68  - 

Analog  and  Digital 
12/T01a      68.302  (Par.  c,d,e,f)  Environmental  simulation; 

68.304  Leakage  current  limit;  68.306 

Hazardous  voltage  limit.;  68.308  Signal  power 

limit.;  68.310  Longitudinal  balance  limit.; 

68.312  On-hook  impedance  limit.;  68.314 

Billing  protection 
12/T01b     68.316  Hearing  Aid  Compatibility:  technical 

standards 

12/TOlc      68.302  Environmental  simulation  (Par.  a,b) 
International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  10041 1-0 
Northern  Telecom  Inc. 

2305  Mission  College  Boulevard 

P.O.  Box  58173 

Santa  Clara,  CA  95052-8173 

Contact:  Mr.  Kenneth  Dorn 

Phone:  408-565-2186 

Fax:  408-565-2575 

E-Mail:  ken.dorn@nt.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  March  31,  1999 
NVLAP 

Code  Designation 

AUSTEL  Technical  Standards  as  determined  under  the 

Telecommunications  Act  of  1991 

12/T41  TS-001 

12/T42  TS-002 

12/T43  TS-003 

12/T44  TS-004 

12/T45  TS-006 

12/T49  TS-016 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T50  AS/NZS  3260 
12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/F0 1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 


1 2/FO  1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 
12/T01       Terminal  Equipment  Network  Protection 

Standards,  FCC  Method  -  47  CFR  Part  68  - 

Analog  and  Digital 
12/T01a      68.302  (Par.  c,d,e,f)  Environmental  simulation; 

68.304  Leakage  current  limit.;  68.306 

Hazardous  voltage  limit.;  68.308  Signal  power 

limit.;  68.310  Longitudinal  balance  limit.; 

68.312  On-hook  impedance  limit.;  68.314 

Billing  protection 
12/T01b     68.316  Hearing  Aid  Compatibility:  technical 

standards 

12/TOlc      68.302  Environmental  simulation  (Par.  a,b) 
International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  100413-0 
Digital  Regulatory  Engineering  and  Testing 
Services 

200  Forest  Street,  Mail  Stop  MROl-D 
Marlboro,  MA  01752-3085 
Contact:  Ms.  Diane  Montvitt 
Phone:  508-467-2851 
Fax:  508-467-2846 

URL:  http://www.digital. com/regulatory 
FCC  Test  Methods 

Accreditation  Valid  Through:  March  31,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 

1 2/FO  1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  la      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22: 1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 


NVLAP  1999  DIRECTORY  -  Page  D32 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  100414-0 
Underwriters  Laboratories  Inc. 

333  Pfingsten  Road 
Northbrook,  IL  60062-2096 
Contact:  Mr.  Rick  A.  Titus 
Phone:  847-272-8800  x43281 
Fax:  847-509-6219 
E-Mail:  titusr@ul.com 
URL:  http://www.ul.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  December  31',  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  la      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
12/F01b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

Thermal  Insulation  Materials 

Accreditation  Valid  Through:  December  31,  1999 

NVLAP 

Code  Designation 
Corrosiveness 

01/C01       ASTM  C739  (Sec.  9) 

01/C02       16  CFR-Part  1209.5 

Flammability 

01/F02       ASTM  E84 

01/F07       16  CFR-Part  1209.6 

01/F08       16  CFR-Part  1209.7 

01/F09       ASTM  C739  (Sec.  10) 

01/F10       ASTM  C739  (Sec.  14) 

Mass,  Density,  and  Dimensional  Stability 

01/D01  ASTMC136 

01/D14       ASTM  C520 

01/D24       ASTM  C739  (Sec.  12) 

01/D26       16  CFR-Part  1209.4 

01/D27       ASTM  C739  (Sec.  8) 

Related  Material  Properties 

01/V05       ASTM  C739  (Sec.  11) 

01/V06       ASTM  C739  (Sec.  15) 

Thermal  Resistance 

01/T06       ASTM  C5 18 

01/T09       ASTM  C653 

01/T10  ASTMC687 


NVLAP  LAB  CODE  100416-0 
SGS  U.S.  Testing  Company,  Inc. 

1341  North  108th  East  Avenue 
Tulsa,  OK  74116-5637 
Contact:  Mr.  Dale  E.  Holloway 
Phone:  918-437-8333 
Fax:  918-437-8487 


Commercial  Products  Testing 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 
Plumbing 

19/F01  ASME  Al  12.18. 1M  (Sec.  5.2) 

19/F02  ASME  Al  12.18. 1M  (Sec.  5.14) 

19/F03  ASME  Al  12.18. 1M  (Sec.  6.2) 

19/F04  ASME  A112.18.1M  (Sec.  6.4) 

19/F05  ASME  A112.18.1M  (Sec.  6.5) 

19/F06  ASME  Al  12.1 8. 1M  (Sec.  6.6) 

19/F07  ASME  Al  12.18. 1M  (Sec.  6.7) 

19/F08  ASME  Al  12.18. 1M  (Sec.  6.8) 

19/F09  ASME  Al  12.18. 1M  (Sec.  5.13) 

19/F10  ASME  Al  12.18. 1M  (Sec.  6.3) 

19/M01  ANSI/CABO  All 7.1  (Sec.  4.24) 

1 9/M02  ASME/ANSI  Al  1 2. 1 9.7M  (Sec.  5,  7) 

19/M03  ASME/ANSI  Al  12.19.8M  (Sec.  4,  5) 

19/M04  ASTMF446 

19/M05  ASTMF462 

19/P01  ANSIZ124.1  (Sec.  4,  5,  6) 

19/P02  ANSI  Z124.2  (Sec.  4,  5,6) 

19/P03  ANSIZ124.3  (Sec.  4,  5,6) 

19/P04  ANSI  Z124.4  (Sec.  4,  5) 

19/P05  ANSI  Z  124.4  (Sec.  8)  per  ASME  Al  12.1 9. 6M 
(Sec.  7.1) 

19/P06  ANSI/IAPMO  Z  124.6  (Sec.  4,  5,  6) 

19/P07  ANSI/IAPMO  Z124.8  (Sec.  4,  5) 

19/V01  ASME  A112.19.2M  (Sec.  7.1) 

19/V02  ASME  Al  12.19. 2M  (Sec.  7.2) 

19/V03  ASME  A112.19.2M  (Sec.  7.3) 

19/V04  ASME  A112.19.2M(Sec.  7.4) 

19/V05  ASME  A112.19.2M  (Sec.  7.5) 

19/V06  ASME  A112.19.2M(Sec.  7.7) 

19/W01  ASME  Al  12.19.6  (Sec.  7.1.2) 

19/W02  ASME  Al  12. 19.6  (Sec.  7.1.3) 

19/W03  ASME  Al  12.19.6  (Sec.  7.1.4) 

19/W04  ASME  Al  12.19.6  (Sec.  7.1.5) 

19AV05  ASME  Al  12.19.6  (Sec.  7.1.6) 

19/W06  ASME  Al  12.19.6  (Sec.  7.1.7) 

19/W07  ASME  Al  12.19.6  (Sec.  7.1.8) 

19/W08  ASME  Al  12.19.6  (Sec.  7.1.9) 

Thermal  Insulation  Materials 
Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 
Corrosiveness 

01/C01  ASTM  C739  (Sec.  9) 

01/C02  16  CFR-Part  1209.5 


NVLAP  1999  DIRECTORY  -  Page  D33 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Flammability 

01/F08       16  CFR-Part  1209.7 
01/F10       ASTM  C739  (Sec.  14) 
Mass,  Density,  and  Dimensional  Stability 
01/D02       ASTM  CI 67 
01/D18       ASTM  D1622 
01/D24       ASTM  C739  (Sec.  12) 
01/D26       16  CFR-Part  1209.4 
01/D27       ASTM  C739  (Sec.  8) 
Related  Material  Properties 
01/V04       ASTM  E96 
01/V05       ASTM  C739  (Sec.  11) 
01/V06       ASTM  C739  (Sec.  15) 
Strength 

01/S02  ASTMC203 

NVLAP  LAB  CODE  100417-0 
Celotex  Technical  Center 

10301  Ninth  Street  North 

St.  Petersburg,  FL  33716-1514 

Contact:  Dr.  Stanley  R.  Prince 

Phone:  727-578-4359 

Fax:  727-578-4280 

E-Mail:  sprince@celotex.com 

URL:  http://www.celotex.com 

Acoustical  Testing  Services 

Accreditation  Valid  Through:  December  31,  1999 

NVLAP 

Code  Designation 

08/P03       ASTM  C423  (ISO  354) 

08/P04  ASTMC522 

08/P06       ASTM  E90(ISO140,Part3) 

08/P07       ASTM  E492 

08/P30       ASTM  E1408 

08/P34  ASTM  E\4\4  (AM A- 1  -II-67)(ISO  1 40,  Part  9) 
Thermal  Insulation  Materials 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

Flammability 

01/F02  ASTME84 

Mass,  Density,  and  Dimensional  Stability 

01/D03  ASTM  C209  (Sec.  6) 

01/D04  ASTM  C209  (Sec.  13) 

01/D05  ASTM  C209  (S.  13)  by  D1037  (S.  100-106) 

01/D06  ASTM  C209  (S.  14)  by  D1037  (S.  107-1 10) 

01/D07  ASTM  C272 

01/D18  ASTM  D1622 

01/D19  ASTM  D2126 

01/D23  ASTM  D2842 

Related  Material  Properties 

01/V04  ASTME96 

Strength 

01/S01a  ASTM  CI 65  (Proc.  A  only) 

01/S02  ASTMC203 

01/S03  ASTM  C209  (Sec.  9) 

0 1  /S04  ASTM  C209  (Sec.  1 0) 

01/S05  ASTM  C209  (Sec.  11) 

01/S06  ASTM  C209  (Sec.  12) 


01/S07  ASTMC273 

01/S10  ASTMD828 

01/S1 1       ASTM  D 1 62 1  (Proc.  A) 

Thermal  Resistance 

01/T04  ASTMC236 

01/T06       ASTM  C5 18  

NVLAP  LAB  CODE  100418-0 
Composite  Panel  Association  (CPA) 

1 8928  Premiere  Court 
Gaithersburg,  MD  20879-1569 
Contact:  Mr.  Gary  Heroux 
Phone: 301-670-0604 
Fax:  301-840-1252 
E-Mail:  glheroux@aol.com 

Wood  Based  Products 

Accreditation  Valid  Through:  September  30,  1999 

NVLAP 

Code  Designation 

General  Wood  Products 

23/G02  ASTM  D 103 7  (Part  A,  Sec.  11-20) 

23/G03  ASTM  D1037  (Part  A,  Sec.  28-33) 
Particleboard  and  Medium-Density  Fiberboard 

23/P02  ASTM  D 1037  (Part  A,  Sec.  61-67) 

23/P03  ASTM  D 103 7  (Part  A,  Sec.  68-73) 

23/P05  ASTM  D1037  (Part  A,  Sec.  100-106) 

23/P06  ASTM  D1037  (Part  A,  Sec.  107-1 10) 

23/P08  ASTM  D1037  (Part  A,  Sec.  126-127) 

23/P09  ANSI/A208.1  (Sec.  3.4.4) 

23/T01  ASTM  El 333 

23/T03  EN  120:92 

23/T04  ASTM  D5582 

23/T05  ASTM  D6007 

NVLAP  LAB  CODE  100419-0 
Test  Site  Services,  Inc. 

P.O.  Box  766 

Marlboro,  MA  01752 

Contact:  Mr.  Richard  L.  Wiedeman 

Phone:  508-481-1684 

Fax:  508-481-1684 

URL:  http://www.ultranet.com/ntss 
FCC  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 


NVLAP  1999  DIRECTORY  -  Page  D34 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

1 2/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  100420-0 
Timberco,  Inc.-  dba  TECO 

86305  College  View  Road 
Eugene,  OR  97405-9631 
Contact:  Mr.  Darin  Thompson 
Phone:  541-746-8271 
Fax:  541-747-1630 

E-Mail:  teco.tested.oregon@worldnet.att.net 


Wood  Based  Products 

Accreditation  Valid  Through:  December  31,  1999 

NVLAP 

Code 

Designation 

General  Wood  Products 

23/G01 

ASTM  D906 

23/G02 

ASTM  D1037  (Part  A,  Sec.  1 1-20) 

23/G03 

ASTM  D1037  (Part  A,  Sec.  28-33) 

23/G04 

ASTM  D2395  (Method  A) 

23/G05 

ASTMD2718 

23/G07 

ASTM  D3043  (Method  C) 

23/G08 

ASTM  D4442  (Method  A) 

23/G09 

ASTM  D4442  (Method  B) 

23/G10 

ASTM  E72 

23/G11 

ASTM  E72  (Wet) 

23/G12 

ASTM  E564 

Hardwood  Plywood 

23/H01 

HP-1  (Sec.  4.3) 

23/H02 

HP-1  (Sec.  4.4) 

23/H03 

HP-1  (Sec.  4.6) 

23/H04 

ASTM  E96 

Particleboard  and  Medium-Density  Fiberboard 

23/P01 

ASTM  D1037  (Part  A,  Sec.  21-27) 

23/P02 

ASTM  D1037  (Part  A,  Sec.  61-67) 

23/P03 

ASTM  D1037  (Part  A,  Sec.  68-73) 

23/P05 

ASTM  D1037  (Part  A,  Sec.  100-106) 

23/P06 

ASTM  D1037  (Part  A,  Sec.  107-1 10) 

23/P07 

ASTM  D 103 7  (Part  A,  Sec.  118-124) 

23/P08 

ASTM  D1037  (Part  A,  Sec.  126-127) 

23/P09 

ANSI/A208.1  (Sec.  3.4.4) 

23/T01 

ASTM  El 333 

23/T02 

FTM  1-83 

23/T04 

ASTM  D5582 

Structural  Composite  Lumber,  Glulam,  I-Joists, 

Laminated  Veneer  Lumber 

23/J01 

ASTM  D143  (Sec.  47-54) 

23/J02 

ASTM  D143  (Sec.  90-94) 

23/J04 

ASTMD198  (Sec.  4-11) 

23/J06 

ASTM  D905 

23/J07 

ASTM  D1037  (Part  A,  Sec.  87-90) 

23/J08 

ASTM  Dl  101 

23/J09 

ASTM  D1761  (Sec.  1-11) 

23/J10 

ASTM  D2559  (Resistance  to  Shear) 

23/J1 1 

ASTM  D2559  (Resistance  to  Delamination) 

23/J12        ASTM  D4688 
23/J13        AITC200  (T106) 
23/J14        AITC200  (T107) 
23/J15  AITC200(T110) 
23/J16  AITC200(T114) 
23/J17  AITC200(T116) 
23/J20        ASTM  D3 110 
Structural  Use  Panels 
23/S04       ASTM  E661 
23/S05       PS-1  (Sec.  4.5.2) 

23/S06  PS-1  (Sec.  4.5.3)  (CAN/CSA-0325.1-88) 
23/S07  PS-2  (Sec.  6.4.1)  (CAN/CSA-0325.1-88) 
23/S08  PS-2  (Sec.  6.4.2)  (CAN/CSA-0325.1-88) 
23/S09  PS-2  (Sec.  6.4.4)  (CAN/CSA-0325. 1  -88) 
23/S10  PS-2  (Sec.  6.4.7)  (CAN/CSA-0325.1-88) 
23/S1 1  PS-2  (Sec.  6.4.8)  (CAN/CSA-0325.1-88) 
23/S12  PS-2  (Sec.  6.4.9)  (CAN/CSA-0325.1-88) 
23/S13  PS-2  (Sec.  6.4.17)  (CAN/CSA-0325.1-88) 
23/S14  PS-2  (Sec.  6.4.18)  (CAN/CSA-0325.1-88) 
23/S15       PS-2  (Sec.  6.4.19)  (Supplement  No.  1-92  to 

CAN/CSA-0325.1-88) 
23/S 1 6       PS-2  (Sec.  6.4.20)  (Supplement  No.  1  -92  to 

CAN/CSA-0325.1-88) 

NVLAP  LAB  CODE  100421-0 

PFS  Corporation 

2402  Daniels  Street 

Madison,  WI  53718-6798 

Contact:  Mr.  James  P.  VanSchoyck 

Phone:  608-221-3361 

Fax:  608-223-5560 

E-Mail:  pfsteco@pfs-teco.com 

URL:  http://www.pfs-teco.com 

Wood  Based  Products 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

General  Wood  Products 

23/G01  ASTMD906 

23/G02  ASTM  D1037  (Part  A,  Sec.  1 1-20) 

23/G03  ASTM  D 1037  (Part  A,  Sec.  28-33) 

23/G04  ASTM  D2395  (Method  A) 

23/G05  ASTM  D2718 

23/G06  ASTM  D27 1 9  (Method  C) 

23/G08  ASTM  D4442  (Method  A) 

23/G09  ASTM  D4442  (Method  B) 

23/G10  ASTME72 

23/G11  ASTM  E72  (Wet) 

23/G12  ASTME564 

23/G13  ASTME695 

23/G14  AFG-0 1-84  (Sec.  3.1) 

23/G15  AFG-0 1-84  (Sec.  3.2) 

23/G16  ASTME489 

23/G17  ASTME767 

23/G 1 8  ASTM  D 1 76 1  (Sec.  41-52) 

Hardwood  Plywood 

23/H01  HP-1  (Sec.  4.3) 

23/H02  HP-1  (Sec.  4.4) 

23/H03  HP-1  (Sec.  4.6) 

23/H04  ASTM  E96 


NVLAP  1999  DIRECTORY  -  Page  D35 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Particleboard  and  Medium-Density  Fiberboard 

23/P01  ASTMD1 037  (Part  A,  Sec.  21-27) 

23/P02  ASTM  D 1037  (Part  A,  Sec.  61-67) 

23/P03  ASTM  D1037  (Part  A,  Sec.  68-73) 

23/P04  ASTM  D 1 037  (Part  A,  Sec.  8 1  -86) 

23/P05  ASTM  D1037  (Part  A,  Sec.  100-106) 

23/P06  ASTM  D1037  (Part  A,  Sec.  107-110) 

23/P07  ASTM  D 1037  (Part  A,  Sec.  118-124) 

23/P08  ASTM  D1037  (Part  A,  Sec.  1*26-127) 

23/P09  ANSI/A208.1  (Sec.  3.4.4) 

23/T01  ASTM  El 333 

23/T02  FTM  1-83 

23/T04  ASTM  D5582 

Sandwich  Constructions 

23/X01  ASTM  C273 

23/X02  ATSM  C297 

23/X03  ASTM  C365  (Method  A) 

23/X04  ASTM  C393 

23/X05  ASTM  C480 

23/X06  ASTMC481 

23/X07  ASTM  Dl  183 

Structural  Composite  Lumber,  Glulam,  I-Joists, 
Laminated  Veneer  Lumber 

23/J01  ASTM  D143  (Sec.  47-54) 

23/J02  ASTM  D143  (Sec.  90-94) 

23/J03  ASTM  D143  (Sec.  100-104) 

23/J04  ASTM  Dl 98  (Sec.  4-1  1 ) 

23/J06  ASTM  D905 

23/J07  ASTM  D1037  (Part  A,  Sec.  87-90) 

23/J08  ASTM  Dl  101 

23/J09  ASTM  D 1761  (Sec.  1-1 1) 

23/J 1 0  ASTM  D2559  (Resistance  to  Shear) 

23/J1 1  ASTM  D2559  (Resistance  to  Delamination) 

23/J  12  ASTM  D4688 

23/J  13  AITC  200(T106) 

23/J14  AITC200  (T107) 

23/J15  AITC  200  (T110) 

23/J16  AITC  200  (T114) 

23/J17  AITC  200(T116) 

23/J20  ASTM  D3 110 

Structural  Use  Panels 

23/S01  ASTM  D3044 

23/S03  ASTM  D3501  (Method  B) 

23/S04  ASTME661 

23/S05  PS-1  (Sec.  4.5.2) 

23/S06  PS-1  (Sec.  4.5.3)  (CAN/CSA-0325.1-88) 

23/S07  PS-2  (Sec.  6.4.1 )  (CAN/CSA-0325.1-88) 

23/S08  PS-2  (Sec.  6.4.2)  (CAN/CSA-0325.1-88) 

23/S09  PS-2  (Sec.  6.4.4)  (CAN/CSA-0325. 1  -88) 

23/S10  PS-2  (Sec.  6.4.7)  (CAN/CSA-0325.1-88) 

23/S1 1  PS-2  (Sec.  6.4.8)  (CAN/CSA-0325.1-88) 

23/S12  PS-2  (Sec.  6.4.9)  (CAN/CSA-0325. 1 -88) 

23/S13  PS-2  (Sec.  6.4. 1 7)  (CAN/CSA-0325. 1-88) 

23/S14  PS-2  (Sec.  6.4. 1 8)  (CAN/CSA-0325. 1 -88) 

23/S15  PS-2  (Sec.  6.4.19)  (Supplement  No.  1-92  to 

CAN/CSA-0325.1-88) 

23/S16  PS-2  (Sec.  6.4.20)  (Supplement  No. 1-92  to 

CAN/CSA-0325.1-88) 


NVLAP  LAB  CODE  100422-0 
PRIMES  (Preflight  Integration  of  Munitions  & 
Electronic  Systems) 

46  TW/TSWW 

401  W.  Choctawhatchee  Ave,  Suite  265 

Eglin  Air  Force  Base,  FL  32542-5724 

Contact:  Mr.  Charles  Steadman 

Phone:  850-882-9354  x509 

Fax:  850-882-9357 

E-Mail:  steadman@eglin.af.mil 

MIL-STD-462  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

Conducted  Emissions: 

1 2/A0 1       MIL-STD-462  Method  CEO  1 

12/A04       MIL-STD-462  Method  CE02 

12/A06       MIL-STD-462  Method  CE03 

1 2/A08       MIL-STD-462  Method  CE04 

1 2/A 1 0       MIL-STD-462  Method  CE06 

1 2/A 1 2       MIL-STD-462  Method  CE07 

Conducted  Susceptibility: 

1 2/BO 1       MIL-STD-462  Method  CS0 1 

12/B02       MIL-STD-462  Method  CS02 

12/B04       MIL-STD-462  Method 

CS03/CS04/CS05/CS08 
12/B05  MIL-STD-462  Method  CS06 
1 2/B06  MIL-STD-462  Method  CS07 
12/B07  MIL-STD-462  Method  CS09 
12/B08  MIL-STD-462  Method  CS10 
1 2/B09  MIL-STD-462  Method  CS 1 1 
12/B10  MIL-STD-462  Method  CS  1 2 
1 2/B 1 1  MIL-STD-462  Method  CS  1 3 
Radiated  Emissions: 
12/D01  MIL-STD-462  Method  RE01 
1 2/D02  MIL-STD-462  Method  RE02 
1 2/D03  MIL-STD-462  Method  RE03 
Radiated  Susceptibility: 
1 2/EO 1  MIL-STD-462  Method  RS0 1 
1 2/E02  MIL-STD-462  Method  RS02 
1 2/E03       MIL-STD-462  Method  RS03  (Consult 

laboratory  for  field  strengths  available) 
1 2/E04       MIL-STD-462  Method  RS03  employing 

RADHAZ  procedures  for  high  level  testing 

(Consult  laboratory  for  field  strengths 

available) 

1 2/E05  MIL-STD-462  Method  RS05 
12/E07       MIL-STD-462  Method  RS06 


NVLAP  1999  DIRECTORY  -  Page  D36 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  100423-0 
APA  -  The  Engineered  Wood  Association 
Research  Center 

7011  South  19th  Street 

P.O.  Box  11700 

Tacoma,WA  98411-0700 

Contact:  Mr.  Michael  R.  O'Halloran,  Ph.D. 

Phone:  253-565-6600 

Fax:  253-565-7265 

E-Mail:  mike.ohalloran@apawood.org 
URL:  http://www.apawood.org 

Wood  Based  Products 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

General  Wood  Products 

23/G05  ASTMD2718 

23/G06       ASTM  D27 1 9  (Method  C) 

23/G07       ASTM  D3043  (Method  C) 

23/G10  ASTME72 

23/G11       ASTM  E72  (Wet) 

Structural  Composite  Lumber,  Glulam,  I-Joists, 

Laminated  Veneer  Lumber 

23/J04        ASTM  D198  (Sec.  4-11) 

23/J05        ASTM  D198  (Sec.  28-35) 

23/J09        ASTM  D 1 76 1  (Sec.  1  - 1 1 ) 

23/J10        ASTM  D2559  (Resistance  to  Shear) 

23/J 1 1        ASTM  D25  5  9  (Resistance  to  Delamination) 

23/J12        ASTM  D4688 

Structural  Use  Panels 

23/S01       ASTM  D3044 

23/S02       ASTM  D3500  (Method  B) 

23/S03       ASTM  D3501  (Method  B) 

23/S04  ASTME661 

23/S07  PS-2  (Sec.  6.4.1)  (CAN/CSA-0325.1-88) 
23/S08  PS-2  (Sec.  6.4.2)  (CAN/CSA-0325.1-88) 
23/S09  PS-2  (Sec.  6.4.4)  (CAN/CSA-0325.1-88) 
23/S10  PS-2  (Sec.  6.4.7)  (CAN/CSA-0325.1-88) 
23/S1 1  PS-2  (Sec.  6.4.8)  (CAN/CSA-0325.1-88) 
23/S12  PS-2  (Sec.  6.4.9)  (CAN/CSA-0325.1-88) 
23/S13  PS-2  (Sec.  6.4.17)  (CAN/CSA-0325.1-88) 
23/S14  PS-2  (Sec.  6.4.18)  (CAN/CSA-0325.1-88) 
23/S15       PS-2  (Sec.  6.4.19)  (Supplement  No.  1 -92  to 

CAN/CSA-0325.1-88) 
23/S16       PS-2  (Sec.  6.4.20)  (Supplement  No.  1-92  to 

CAN/CSA-0325.1-88) 


I 


NVLAP  LAB  CODE  100424-0 
Vibro-Acoustics  Laboratory 

727  Tapscott  Road 
Scarborough  Ontario  MIX  1A2 
CANADA 

Contact:  Mr.  Robert  Gault 

Phone:  416-291-7371 

Fax: 416-291-8049 

E-Mail:  bqault@vibro-acoustics.com 

Acoustical  Testing  Services 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

08/P36       ASTM  E477  

NVLAP  LAB  CODE  100425-0 
Johns  Manville  Technical  Center 

10100  West  Ute  Avenue 
P.O.  Box  625005 
Littleton,  CO  80162-5005 
Contact:  Mr.  Mark  A.  Albers 
Phone:  303-978-5008 
Fax:  303-978-3123 
E-Mail:  albersm@jm.com 

URL:  http://www.schuller.com/mtc/appliedtech.html 

Acoustical  Testing  Services 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

08/P03  ASTM  C423  (ISO  354) 

08/P04  ASTMC522 

08/P06  ASTM  E90  (ISO  1 40,  Part  3 ) 

08/P10  ANSI  SI 2.31  (ISO  3741) 

08/P13  ANSI  S12. 32  (ISO  3742) 

08/P24  ANSI  S 1 2. 1 0  (ISO  7779) 

08/P33  ASTM  El  111 

08/P34  ASTM  E1414  (AMA-l-II-67)(ISO  140,  Part  9) 

08/P35  ASTM  El 050 

08/P36  ASTM  E477 

Thermal  Insulation  Materials 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 
Flammability 

01/F01  TAPPIT461-OM 

01/F02  ASTME84 

01/F05  ASTM  El 36 

Mass,  Density,  and  Dimensional  Stability 

01/D02  ASTM  CI 67 

01/D03  ASTM  C209  (Sec.  6) 

01/D04  ASTM  C209  (Sec.  13) 

01/D05  ASTM  C209  (S.  13)  by  D1037  (S.  100-106) 

01/D08  ASTM  C302 

01/D09  ASTMC303 

01/D11  ASTMC356 

01/D12  ASTMC411 

01/D13  ASTMC519 


NVLAP  1999  DIRECTORY  -  Page  D37 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Related  Material  Properties 

01/V04       ASTM  E96 

0 1  /V07       ASTM  C 1 1 04/C 1 1 04M 

Strength 

01/S01a      ASTM  CI 65  (Proc.  A  only) 

01/S02  ASTMC203 

01/S03       ASTM  C209  (Sec.  9) 

01/S04       ASTM  C209  (Sec.  10) 

01/S05       ASTM  C209  (Sec.  11) 

01/S06       ASTM  C209  (Sec.  12) 

01/S08  ASTMC446 

01/S10  ASTMD828 

Thermal  Resistance 

01/T01       ASTM  CI 77 

01/T05  ASTMC335 

01/T06       ASTM  C5 18 

01/T10  ASTMC687 

01/T11  ASTMC976 

NVLAP  LAB  CODE  100426-0 

KTL  Dallas,  Inc. 

802  N.  Kealy 

Lewisville,  TX  75057-3136 

Contact:  Ms.  Pat  Wellborn 

Phone:  972-436-9600 

Fax:  972-436-2667 

E-Mail:  pwellborn@icomply.com 

URL:  http://www.icomply.com  or  http://www.ktl.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

AUSTEL  Technical  Standards  as  determined  under  the 

Telecommunications  Act  of  1991 

12/T41  TS-001 

12/T42  TS-002 

12/T43  TS-003 

12/T44  TS-004 

12/T45  TS-006 

12/T46  TS-008 

12/T49  TS-016 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T50  AS/NZS  3260 
12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 
1 2/TO 1       Terminal  Equipment  Network  Protection 

Standards,  FCC  Method  -  47  CFR  Part  68  - 

Analog  and  Digital 
1 2/TO  la     68.302  (Par.  c,d,e,f)  Environmental  simulation; 

68.304  Leakage  current  limit.;  68.306 

Hazardous  voltage  limit.;  68.308  Signal  power 

limit.;  68.310  Longitudinal  balance  limit.; 

68.312  On-hook  impedance  limit.;  68.314 


Billing  protection 
12/T01b     68.316  Hearing  Aid  Compatibility:  technical 
standards 

12/T01c      68.302  Environmental  simulation  (Par.  a,b) 
International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22: 1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  100427-0 

Michael  &  Associates 

246  Woodland  Drive 

State  College,  PA  16803 

Contact:  Mr.  Kevin  Michael 

Phone:  814-234-7042 

Fax:  814-235-1381 

E-Mail:  Michaell@vicon.net 

URL:  http://www.michaell@vicon.net 

Acoustical  Testing  Services 

Accreditation  Valid  Through:  December  31,  1999 

NVLAP 

Code  Designation 

08/P26       ANSI  S3. 19  (ANSI  S3. 19-1 974) 
08/P27       ANSI  SI 2. 6 

NVLAP  LAB  CODE  100428-0 
Matsushita  EMC  Center 

Yunitopia  Sasayama,  Yashiro 

Sasayama-cho 

Taki-gun,  Hyogo  669-2356 

JAPAN 

Contact:  Mr.  Katsuo  Ishihara 

Phone:  81-795-52-5681 

Fax:  81-795-52-5682 

E-Mail:  PAN02796@pas.mei.co.jp 

FCC  Test  Methods 

Accreditation  Valid  Through:  December  31,  1999 

NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 

12/F01        FCC  Method  -  47  CFR  Part  15  -  Digital 
Devices 

1 2/FO  la      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  1  b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22: 1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 


NVLAP  1999  DIRECTORY  -  Page  D38 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  100429-0 
Queen  Carpet  Test  Laboratory 

2305  Lakeland  Road,  P.O.  Box  1527 
Dalton,  GA  30722-1527 
Contact:  Mr.  Brian  Medlin 
Phone:  706-277-1900 
Fax:  706-277-5497 


Carpet  and  Carpet  Cushion 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

Tests  Applicable  to  Carpet  and  Carpet  Cushion 

03/T01       AATCC  16  (Option  E) 
03/T02       ASTMD2646  (Sees.  16-24) 
03/T04       1 6  CFR  Part  1 63  0  (FF- 1  -70) 
Tests  Applicable  to  Carpets 


03/G04 

AATCC  165 

03/G05 

ASTM  D418(Sec.  8) 

03/G06 

ASTMD418(Sec.  9) 

03/G07 

ASTM  D4 18  (Sees.  10-11) 

03/G08 

ASTM  D418  (Sec.  13) 

03/G09 

ASTM  D1335 

03/G10 

ASTM  D3936 

03/G12 

ASTM  E648 

NVLAP  LAB  CODE  100430-0 
Professional  Service  Industries,  Inc.,  Pittsburgh 
Test.  Lab.  Div. 

2710  West  5th  Avenue 

Eugene,  OR  97402 

Contact:  Mr.  Randy  T.  Webb 

Phone:  541-484-9212 

Fax:  541-344-2735 

E-Mail:  randy.webb@psi-inc.com 

Wood  Based  Products 

Accreditation  Valid  Through:  March  31,  1999 
NVLAP 

Code  Designation 

General  Wood  Products 

23/G02       ASTM  D1037  (Part  A,  Sec.  1 1-20) 
23/G03       ASTMD1037  (Part  A,  Sec.  28-33) 
23/G08       ASTM  D4442  (Method  A) 
23/G10  ASTME72 
23/G11       ASTM  E72  (Wet) 
Hardwood  Plywood 
23/H01       HP-1  (Sec.  4.3) 
23/H02       HP-1  (Sec.  4.4) 
23/H03       HP-1  (Sec.  4.6) 
Particleboard  and  Medium-Density  Fiberboard 
23/P04       ASTM  D 103 7  (Part  A,  Sec.  81-86) 
23/P05       ASTM  D1037  (Part  A,  Sec.  100-106) 
23/P06       ASTM  D1037  (Part  A,  Sec.  107-1 10) 
23/P07       ASTM  D1037  (Part  A,  Sec.  1 18-124) 
23/P08       ASTM  D1037  (Part  A,  Sec.  126-127) 
23/P09       ANSI/A208.1  (Sec.  3.4.4) 
23/T01       ASTM  El 333 


23/T02  FTM  1-83 
Structural  Use  Panels 

23/S04  ASTME661 
23/S05       PS-1  (Sec.  4.5.2) 

23/S06  PS-1  (Sec.  4.5.3)  (CAN/CSA-0325.1-88) 
23/S07  PS-2  (Sec.  6.4.1)  (CAN/CSA-0325.1-88) 
23/S08  PS-2  (Sec.  6.4.2)  (CAN/CSA-0325. 1  -88) 
23/S09  PS-2  (Sec.  6.4.4)  (CAN/CSA-0325. 1-88) 
23/S10  PS-2  (Sec.  6.4.7)  (CAN/CSA-0325.1-88) 
23/S11  PS-2  (Sec.  6.4.8)  (CAN/CSA-0325.1-88) 
23/S12  PS-2  (Sec.  6.4.9)  (CAN/CSA-0325.1-88) 
23/S13  PS-2  (Sec.  6.4.17)  (CAN/CSA-0325.1-88) 
23/S14  PS-2  (Sec.  6.4.18)  (CAN/CSA-0325.1-88) 
23/S 1 5       PS-2  (Sec.  6.4.19)  (Supplement  No.  1  -92  to 

CAN/CSA-0325.1-88) 
23/S  16       PS-2  (Sec.  6.4.20)  (Supplement  No.  1-92  to 

 CAN/CSA-0325.1-88)  

NVLAP  LAB  CODE  100431-0 
PCTEST  Engineering  Laboratory,  Inc. 
6660-B  Dobbin  Road 
Columbia,  MD  21045-4708 
Contact:  Mr.  Randy  Ortanez 
Phone:  410-290-6652 
Fax:  410-290-6654 
E-Mail:  randy@pctestlab.com 
URL:  http://www.pctestlab.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
12/F01b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

1 2/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  100432-0 
InfoGard  Laboratories,  Inc. 

641  Higuera  Street,  Second  Floor 

San  Luis  Obispo,  CA  93401 

Contact:  Ms.  Emily  Culligan 

Phone:  805-783-0810 

Fax:  805-783-0889 

E-Mail:  eculligan@infogard.com 

URL:  http://www.infogard.com 


NVLAP  1999  DIRECTORY  -  Page  D39 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Cryptographic  Modules  Testing 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

17/C01       NIST-CSTT:  140-1;  National  Institute  of 
Standards  and  Technology-Cryptographic 
Support  Test  Tool  (CSTT)  for  the  Federal 
Information  Processing  Standard  140-1  (FIPS 
140-1)  "Security  Requirements  for 
Cryptographic  Modules." 

1 7/C0 1  a     Test  Method  Group  1 :  All  test  methods  derived 
from  FIPS  140-1  and  specified  in  the  CSTT, 
except  those  listed  in  Group  2  and  Group  3. 

1 7/CO lb     Test  Method  Group  2 :  Test  methods  for 

Physical  Security,  Level  4  derived  from  FIPS 
140-1  and  specified  in  the  CSTT 

1 7/C0 1  c     Test  Method  Group  3 :  Test  methods  for 

Software  Security,  Level  4  derived  from  FIPS 
140-1  and  specified  in  the  CSTT 

NVLAP  LAB  CODE  100501-0 
Baltimore  Gas  &  Electric  Company 

1650  Calvert  Cliffs  Parkway 
Lusby,  MD  20657-4702 
Contact:  Mr.  Danny  R.  Adams 
Phone: 410-495-2216 
Fax:  410-495-2263 


Ionizing  Radiation  Dosimetry 

Accreditation  Valid  Through:  September  30,  1999 

This  facility  has  been  evaluated  and  deemed  competent  to 
process  the  radiation  dosimeter  listed  below  through 
employing  a  Panasonic  automatic  reader  UD710A. 

This  facility  is  accredited  to  process  the  following 
dosimeter  by  virtue  of  actual  demonstration  of  compliance 
with  ANSI  HPS  Nl 3.1  1-1993  through  testing. 

Panasonic  TLD  model  UD802  in  a  Panasonic  UD874A 
holder  for  ANSI-N13.1 1  categories  I,  II,  III  A,  IV,  VC,  VI, 
VII,  VIII. 

NVLAP  LAB  CODE  100502-0 
Union  Electric  Company,  Callaway  Plant 

P.O.  Box  620 

Fulton,  MO  65251-0620 

Contact:  Mr.  Christopher  C.  Graham 

Phone:  573-676-8380 

Fax:  573-676-4476 

E-Mail:  ccgraham@cal.ameren.com 

Ionizing  Radiation  Dosimetry 

Accreditation  Valid  Through:  March  31,  1999 

This  facility  has  been  evaluated  and  deemed  competent  to 


process  the  radiation  dosimeter  listed  below  through 
employing  a  Panasonic  Automatic  reader  model  UD710A. 

This  facility  is  accredited  to  process  the  following 
dosimeter  by  virtue  of  actual  demonstration  of  compliance 
with  ANSI  HPS  N 1 3 . 1  1  - 1 993  through  testing. 

Panasonic  TLD  model  UD-802-AS  in  a  Panasonic 
UD-874A  holder  for  ANSI  HPS  N  13.1 1  categories  I,  II, 

IIIA,  IV,  VC,  VI,  VII,  VIII.  

NVLAP  LAB  CODE  100503-0 
Mallinckrodt  Group,  Inc. 

2703  Wagner  Place 

Maryland  Heights,  MO  63043 

Contact:  Mr.  Roger  Moroney 

Phone:  314-654-7457 

Fax:  314-654-7998 

E-Mail:  roger.moroney@mkg.com 

Ionizing  Radiation  Dosimetry 

Accreditation  Valid  Through:  September  30,  1999 

This  facility  has  been  evaluated  and  deemed  competent  to 
process  the  radiation  dosimeter  listed  below  through 
employing  Harshaw  automatic  reader  model  6600E. 

This  facility  is  accredited  to  process  the  following 
dosimeter  by  virtue  of  actual  demonstration  of  compliance 
with  ANSI  HPS  N13.1 1-1993  through  testing. 

Harshaw  TLD  model  8825  for  ANSI-N13.1 1  catergories  II, 

IIIB,  IV,  VC,  VI,  VII. 

NVLAP  LAB  CODE  100504-0 
Naval  Dosimetry  Center 

National  Naval  Medical  Center 
Bethesda,  MD  20889-5614 
Contact:  CAPT  K.  Mendenhall 
Phone: 301-295-0142/5410 
Fax:  301-295-5981 

E-Mail:  kmendenhall@navdoscen.med.navy.mil 

Ionizing  Radiation  Dosimetry 

Accreditation  Valid  Through:  December  31,  1999 

This  facility  has  been  evaluated  and  deemed  competent  to 
process  the  radiation  dosimeters  listed  below  through 
employing  the  Harshaw  automatic  reader  models  8800  and 

6600. 

This  facility  is  accredited  to  process  the  following 
dosimeters  by  virtue  of  actual  demonstration  of  compliance 
with  ANSI  HPS  N  13.1  1-1993  and  ANSI  HPS 
N13.32-1995  through  testing. 


NVLAP  1999  DIRECTORY  -  Page  D40 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Harshaw  8801  (DT  648/PD)(Harshaw  4  Chip  Card,  3 
TLD700,  1  TLD600)  in  a  Type  88  holder  for 
ANSI-N13.il  categories  I,  II,  IIIA,  IIIB,  IV,  VA,  VI,  VII, 
VIII. 

Harshaw  extremity  TLD  XD-1 00  in  a  finger  ring  holder  for 
ANSI  HPS  N  13.32  (NIST  Handbook  150-4,  Table  2) 
categories  I,  II,  IIIB,  IV,  VA. 

NVLAP  LAB  CODE  100505-0 
Duke  Power  Company  Dosimetry  Laboratory 

526  South  Church  Street 

P.O.  Box  1006 

Charlotte,  NC  28201-1006 

Contact:  Mr.  Donald  N.  Mei 

Phone:  704-382-7547 

Fax:  704-382-4477 

E-Mail:  dnmei@duke.-energy.com 

Ionizing  Radiation  Dosimetry 

Accreditation  Valid  Through:  March  31,  1999 

This  facility  has  been  evaluated  and  deemed  competent  to 
process  the  radiation  dosimeter  listed  below  through 
employing  a  Harshaw  Model  8800. 

This  facility  is  accredited  to  process  the  following 
dosimeters  by  virtue  of  actual  demonstration  of  compliance 
with  ANSI  HPS  N 1 3 . 1 1  - 1 993  through  testing. 

Harshaw  TLD  card  Type  8801  in  a  model  8814  BGN 
holder  for  ANSI-N13.1 1  categories  I,  II,  IIIA,  IV,  VB,  VI, 
VII,  VIII.  

NVLAP  LAB  CODE  100506-0 
Southern  California  Edison 

San  Onofre  Nuclear  Generating  Station 

5000  Pacific  Coast  Highway,  P.O.  Box  128 

San  Clemente,  CA  92674-0128 

Contact:  Mr.  James  Rolph 

Phone: 949-368-7050 

Fax:  949-368-6049 

E-Mail:  rolphjt@songs.sce.com 

Ionizing  Radiation  Dosimetry 

Accreditation  Valid  Through:  September  30,  1999 

This  facility  has  been  evaluated  and  deemed  competent  to 
process  the  radiation  dosimeter  listed  below  through 
employing  a  Panasonic  automatic  reader  model  UD710A. 

This  facility  is  accredited  to  process  the  following 
dosimeter  by  virtue  of  actual  demonstration  of  compliance 
with  ANSI  HPS-N 1 3 . 1  1  - 1 993  through  testing. 

Panasonic  TLD  model  UD802-AS2  in  an  ISA  model  821 
holder  for  ANSI-N13.1 1  categories  I,  II,  IIIB,  IV,  VC,  VI, 
VII. 


NVLAP  LAB  CODE  100510-0 

GPU  Nuclear  Corp. 

Three  Mile  Island,  Route  441  South 
P.O.  Box  480 

Middletown,  PA  17057-0480 
Contact:  Mr.  J.  W.  Schmidt 
Phone:  717-948-8744 
Fax:  717-948-8549 


Ionizing  Radiation  Dosimetry 

Accreditation  Valid  Through:  September  30,  1999 

This  facility  has  been  evaluated  and  deemed  competent  to 
process  the  radiation  dosimeters  listed  below  through 
employing  a  Panasonic  automatic  reader  model  UD-710A. 

This  facility  is  accredited  to  process  the  following 
dosimeters  by  virtue  of  actual  demonstration  of  compliance 
with  ANSI  HPS  Nl 3.1 1-1993  through  testing. 

Panasonic  TLD  model  UD802-AS2  in  an  ISA  model  830 
hanger  for  ANSI-N13.1 1  categories  I,  II,  IIIA,  IV,  VC,  VI, 
VII. 

Panasonic  TLD  model  UD802-AS2N  in  an  ISA  model  830 
hanger  with  Cd  over  elements  1  and  2,  Pb  filtration  oven 
element  4  for  ANSI-N13.1 1  category  VIII. 

NVLAP  LAB  CODE  100512-0 
Radiation  Detection  Company 
162  N.  Wolfe  Road 
P.O.  Box  3414 
Sunnyvale,  CA  94088-3414 
Contact:  Mr.  Richard  H.  Holden 
Phone:  408-735-8700 
Fax:  408-735-0126 
E-Mail:  BaLaing@aol.com 
URL:  http://www.RadiationDetection.com 

Ionizing  Radiation  Dosimetry 

Accreditation  Valid  Through:  December  31,  1999 

This  facility  has  been  evaluated  and  deemed  competent  to 
process  the  radiation  dosimeters  listed  below  through 
employing  (1)  Teledyne  7300  and  310  reader;  (2)  Harshaw 
3000A  and  3500  reader;  (3)  Victoreen  2800  reader;  (4)  by 
manual  film  processing  and  reading  on  a  Macbeth  TD932 
densitometer;  (5)  Tracketch;  or  (6)  NE  Autoscan  60 
system  and  Ziess  microscope. 

This  facility  is  accredited  to  process  the  following 
dosimeters  by  virtue  of  actual  demonstration  of  compliance 
with  ANSI  HPS  N 1 3 . 1 1  - 1 993  through  testing. 


NVLAP  1999  DIRECTORY  -  Page  D41 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


DESIGNATION 


PROCESS 


ANSI-N13.il 
CATEGORIES 


process  the  radiation  dosimeters  listed  below  through 
employing  a  Panasonic  automatic  reader  model  UD710A. 


Hi  Energy 
Photons  TLD-100 
powder 

(Type  06  &  09) 
Lo  Energy 

Photons  TLD-100 

powder  &  chips 

(Type  06  &  09) 
TLD  Albedo 

(Type  22) 
Film  XBG 

(Type  01) 
Neutron  Tracketch 

CR-39 

(Type  23) 
Neutron  Tracketch 

PN-3 

(Type  23) 
Beta/gamma 

Albedo  TLD 

(Type  23) 
TLD-Beta/gamma- 

TLD  100 

powder  &  chips 

(Type  30) 
TLD-Beta/gamma- 

TLD  100 

powder  &  chips 

(Type  9) 


2,3 


1,2  or  3 


1,2 


II,  IV 


I,  IIIA,  VI 


2  or  3,4  VIII 


I,  II,  IIIA,  IIIB,  IV, 
VA,  VI,  VII 

VIII 


VIII 


II,  IV,  VA,  VII 


I,  IIIA,  IIIB,  VA,  VB, 
VI 


VA,  VII 


*  Processes  listed  above,  2  and  3,  are  considered 
functionally  acceptable  as  substitutes  which  can  be  used  in 
lieu  of  process  1  as  listed  above. 

Extremity  Finger  Ring  Type  05  Harshaw  TLD-100 
dosimeter  for  ANSI  HPS  N  13.32- 1995  and  NIST 
Handbook  150-4,  table  2  categories  II,  IVA,  IVB,  VA 
through  testing. 


NVLAP  LAB  CODE  100514-0 
Ginna  Nuclear  Station 

1503  Lake  Road 
Ontario,  NY  14519-9742 
Contact:  Mr.  William  H.  Thomson 
Phone:  716-771-3323 
Fax:  716-771-3905 


Ionizing  Radiation  Dosimetry 

Accreditation  Valid  Through:  September  30,  1999 


This  facility  is  accredited  to  process  the  following 
dosimeters  by  virtue  of  actual  demonstration  of  compliance 
with  ANSI  HPS-N  13.1 1-1993  through  testing. 

Panasonic  TLD  model  UD802-AS  in  an  ISA  Model  821 
hanger  for  ANSI-N13.1 1  categories  I,  II,  IIIB,  IV,  VA,  VI, 
VII. 

Panasonic  TLD  model  UD812A-5  in  a  Panasonic 
UD874A-T  hanger  for  ANSI-N13.1 1  categories  I,  II,  IV, 
V,  VII. 

Combination  Panasonic  TLD  model  UD812A-5  and 
UD809-AS  in  a  Panasonic  UD884A-T  holder  with  cd 
shields  for  ANSI-N1 3. 1 1  category  VIII. 

NVLAP  LAB  CODE  100515-0 
Eberline  Dosimetry  Service 

7021  Pan  American  Highway  NE 
Albuquerque,  NM  87109 
Contact:  Mr.  Ernest  A.  Sanchez 
Phone:  505-345-3461 
Fax:  505-761-5410 
E-Mail:  nutech@flash.net 

Ionizing  Radiation  Dosimetry 

Accreditation  Valid  Through:  June  30,  1999 

This  facility  has  been  evaluated  and  deemed  competent  to 
process  the  radiation  dosimeters  listed  below  through 
employing  a  Eberline  manual  reader  TLR-6  and  the 
Harshaw  automatic  readers  model  8800  and  6600. 

This  facility  is  accredited  to  process  the  following 
dosimeters  by  virtue  of  actual  demonstration  of  compliance 
with  ANSI  HPS  N  13.1 1-1993  through  testing. 

Eberline  TLD-100  (2  or  3  TLD  chips)  for  ANSI-N13.1 1 
categories  I,  II,  IIIA,  IIIB,  IV,  VA,  VI,  VII,  VIII. 

Eberline  Albedo  TLD-100  for  ANSI-N13.1 1  category  VIII. 

Eberline  TLD-100  extremity  dosimeter  in  an  elastic  ring 
holder  for  ANSI  HPS  N  13.32  and  NIST  Handbook  150-4, 
table  2  categories  I,  II,  IIIA,  IV,  VA. 

Harshaw  TLD-8814  for  ANSI-N13.1 1  categories  I,  II,  IIIA, 
IIIB,  IV,  VC,  VI,  VII. 

Harshaw  TLD-8806  for  ANSI-N13.1 1  category  VIII. 


This  facility  has  been  evaluated  and  deemed  competent  to 


NVLAP  1999  DIRECTORY  -  Page  D42 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  100516-0 
Tennessee  Valley  Authority  External  Dosimetry 
Service 

Sequoyah  Access  Road,  P.O.  Box  2000 

Soddy-Daisy,  TN  37379-2000 

Contact:  Mr.  Mark  A.  Palmer 

Phone:  423-843-8857 

Fax:  423-843-7133 

E-Mail:  MAPALMER@TVA.GOV 

Ionizing  Radiation  Dosimetry 

Accreditation  Valid  Through:  March  31,  1999 

This  facility  has  been  evaluated  and  deemed  competent  to 
process  the  radiation  dosimeters  listed  below  through 
employing  a  Panasonic  automatic  reader  model  UD710A. 

This  facility  is  accredited  to  process  the  following 
dosimeter  by  virtue  of  actual  demonstration  of  compliance 
with  ANSI  HPS  N 1 3 . 11-1993  through  testing. 

Panasonic  TLD  model  UD802-AS  in  a  Panasonic 
UD874AT  holder  for  ANSI  HPS  N13.1 1  categories  I,  II, 
IIIA,  IV,  VC,  VI,  VII,  VIII. 

NVLAP  LAB  CODE  100517-0 
Carolina  Power  &  Light  Company,  Harris  Energy 
&  Enviro.  Center 

3932  New  Hill-Holleman  Road 
P.O.  Box  327 

New  Hill,  NC  27562-0327 

Contact:  Mr.  A.  G.  Cheatham 

Phone:  919-362-3215 

Fax:  919-362-3354 

E-Mail:  gooch.cheatham@cplc.com 

Ionizing  Radiation  Dosimetry 

Accreditation  Valid  Through:  September  30,  1999 

This  facility  has  been  evaluated  and  deemed  competent  to 
process  the  TLD  radiation  dosimeters  listed  below  through 
employing  a  Panasonic  automatic  reader  model  UD710A. 

This  facility  is  accredited  to  process  the  following 
dosimeter  by  virtue  of  actual  demonstration  of  compliance 
with  ANSI  HPS-N 1 3 . 1 1  - 1 993  and  HPS 
ANSI-N13.32-1995  through  testing. 

Panasonic  TLD  model  UD802  in  a  Panasonic  closed  type 
UD-874  ATM1  holder  for  ANSI-N13.il  categories  I,  II, 
IIIA,  IV,  VC,  VI,  VII,  VIII. 

Panasonic  extremity  TLD  model  UD-807  in  a  plastic  ring 
holder  for  HPS  ANSI-13.32  (NIST  Handbook  150-4,  table 
2)  category  IVA. 

Merlin  Gerin  DMC-100  Electronic  Personal  Dosimeter 


(EPD)  with  LDM-101  reader  for  ANSI  N  13.1 1  category 
IV. 

Based  on  equivalency,  the  Panasonic  TLD  model  UD802 
in  a  wrist  holder  for  HPS  ANSI-13.32  (NIST  Handbook 
150-4,  table  2)  categories  I,  II,  IIIA,  IV,  VC,  VI,  VII. 

Based  on  equivalency,  the  DMC-100  Electronic  Personal 
Dosimeter  (EPD)  in  a  wrist  holder  for  HPS  ANSI-13.32 
(NIST  Handbook  150-4,  table  2)  category  IV. 

NVLAP  LAB  CODE  100518-0 

Landauer,  Inc. 

2  Science  Road 

Glenwood,  IL  60425-1586 

Contact:  Dr.  R.  Craig  Yoder 

Phone:  708-755-7000 

Fax:  708-755-7011 

E-Mail:  cyoder@landauerinc.com 

URL:  http://www.landauerinc.com 

Ionizing  Radiation  Dosimetry 

Accreditation  Valid  Through:  December  31,  1999 

This  facility  has  been  evaluated  and  deemed  competent  to 
process  the  radiation  dosimeters  listed  below  through 
employing  (1)  Landauer  (Kanars  Data)  automatic  film 
reader;  (2)  Harshaw  2000  B/D  Laser  reader;  (3)  CR-39 
manual  optical  readers;  (4)  manual  densitometers  X-Rite, 
Tech/Ops  Model  301,  Macbeth  Model  TD504,  TD931, 
TD904;  (5)  ALNOR  Dosacus  reader;  or  (6)  Landauer 
Custom  Automated  and  Manual  Delayed  Optically 
Stimulated  Luminescence  (DOSL)  Luxel  reader  and  (7) 
Pulsed  Optically  Stimulated  Luminescence  (POSL). 

This  facility  is  accredited  to  process  the  following 
dosimeters  by  virtue  of  actual  demonstration  of  compliance 
with  ANSI  HPS  N13T  1-1993  through  testing. 


Landauer  designation: 


DOSIMETER 


PROCESS 


Based 
On 

Testing 


ANSIN13.il 
CATEGORY 


Based 
On  Tech. 
Equiv. 


FILM 

G  -  Film  "GARDRAY"(A)  1,4 
R  -  G  badge  plus 

ER(G)  1,2,3,4 
R  -  G  badge  plus 

ALNOR  ER(M)  1,3,4,5 
B  -  G  badge  plus 

CR39(L)  1,3,4 


I-VII 
VIII 
VIII 
VIII 


I-VII 
I-VII 
I-VII 


NVLAP  1999  DIRECTORY  -  Page  D43 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


C  -  G  badge  plus 

CR-39  and  Cadmium 
J  -  G  badge  plus 

polycarbonate 

and  Cadmium 
Y  -  G  badge  plus 

Cadmium 
Q  -  DEX-RAY 

TLD 

K - ALNOR 

(TLD  100  chips)(K)(H) 
W  -  modified  -  2  chip 

Escort  with  x-ray 

filtration  (J) 
Z  -  K  badge 

(TLD  700  chips) 

plus  Neutron  Track 

Etch  CR39(T)(I) 
F  -  L  badge  plus 

CR-39 
F  -  L  badge  plus  ER 
L -4  chip  Alnor  TLD 
M - K  badge 

(TLD  700  chips) 
S  -  K  badge 

(TLD  700  chips) 

plus  ER 
Z  -  K  badge 

(TLD  700  chips) 

plus  polycarbonate 

DOSL 

H-Luxel  type  H 
POSL 

J-Luxel  (003/POSL) 
P-Luxel  (003/POSL) 


1,3,4 


1,3,4 

1,3,4 
1,3,4 


3,5 

1,3 
1,2,3 
5 


3,5 


3,5 


I-VII 


I.  II 


VIII 


I-VIII 

I-VIII 

I-VII 
I-VII 


I-VII 


VIII 
I,  II,  IIIA,  IV 
VC,  VI,  VII 


I-VII 

I-VIII 
I-VIII 
I-VII 

I-VII 
I-VIII 
I-VIII 

VIII 


Landauer,  Inc.  Company  Offices:  El  Segundo,  California; 
Houston,  Texas;  and  East  Brunswick,  New  Jersey. 

This  facility  has  been  accredited  to  process  the  extremity 
dosimeters  listed  below,  by  virtue  of  actual  demonstration 
of  compliance  with  ANSI-N13. 32-1995  andNIST 
Handbook  150-4,  Pg.  14,  Table  2,  through  employing  the 
following  readers/process:  (1 )  Landauer  Custom 
Automated,  (2)  Kanars  Data  Custom  Automated  (film),  (3) 
Alnor  Dosacus  Automatic  Reader,  (4)  Harshaw  2000B/D, 
3000,  4000  manual,  (5)  Macbeth  TD504,  TD904,  TD931 
manual,  and  (6)  Landauer  Custom  Luxel  reader  (7)  Pulsed 
Optically  Stimulated  Luminescence  (POSL). 


DOSIMETER 


PROCESS 


TLD 

U  -  Ring  (B) 
(Finger) 


1.4 


K  -  Modified  K  (H) 
(Wrist)  3,4 


FILM 


G  -  Gardray  (A) 
(Wrist) 


DOSL 

H-Luxel  type  H 
(Wrist) 


POSL 


Based 
On 

Testing 


I,  II,  IIIA, 
IV,  VA,  VB, 
VD,  VI,  VII 

IIIA  and  VI 


2,5      IIIA  and  VI 


IIIA  and  VI 


ANSIN13.il 
CATEGORY 

Based 
On  Tech. 
Equiv. 


I,  II,  IV,  VA, 
VB,  VD,  VII 


I,  II,  IV,  VA, 
VB,  VD,  VII 


I,  II,  IV,  VA, 
VB,  VII 


The  following  sites  are  included  to  perform  limited 
volume,  emergency  response  processing  employing  either  a 
Harshaw  3000  manual  reader  or  manual  film  processing 
techniques  for  the  following  badges: 


P-Luxel  (003/POSL)  7     IIIA  and  VI 


I,  II,  IV,  VA, 
VB,  VII 


DOSIMETER 
G  -  Film  "GARDRAY" 
L  -  TLD  4  chip  "ALNOR" 
K  -  TLD  3  chip  "ALNOR" 


ANSIN13.il  CATEGORY 
I  through  VII 
I  through  VII 
I  through  VII 


NVLAP  1999  DIRECTORY  -  Page  D44 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  100519-0 
South  Texas  Project  Dosimetry  Laboratory 

P.O.  Box  289 
Wadsworth,  TX  77483 
Contact:  Mr.  G.  T.  Powell 
Phone:  512-972-7566 
Fax: 512-972-7757 
E-Mail:  gtpowell@stpegs.com 

Ionizing  Radiation  Dosimetry 

Accreditation  Valid  Through:  September  30,  1999 

This  facility  has  been  evaluated  and  deemed  competent  to 
process  the  radiation  dosimeters  listed  below  through 
employing  a  Panasonic  automatic  reader  model  UD710A. 

This  facility  is  accredited  to  process  the  following 
dosimeters  by  virtue  of  actual  demonstration  of  compliance 
with  ANSI  HPS-N1 3.1  1-1993  through  testing. 

Panasonic  TLD  Model  UD802-AT  in  an  ISA  Model  830 
holder  for  ANSI-N13.1 1  categories  II,  IV,  VC,  VI,  VII. 

Panasonic  TLD  Model  UD802-AT  in  an  ISA  Model  810 
holder  for  ANSI-N13.1 1  category  VIII. 

Panasonic  TLD  Model  UD802/Neutron  Pack  in  a  Model 
ISA  830/ISA  810  holder  for  ANSI-N13.il  category  VIII. 

NVLAP  LAB  CODE  100521-0 
Duquesne  Light  Company,  Beaver  Valley  Power 
Station 

Mail  Drop  BV-ERF 
P.O.  Box  4 

Shippingport,  PA  15077-0004 
Contact:  Mr.  John  T.  Lebda 
Phone:  412-393-5872 
Fax:  412-393-5621 

E-Mail:  John_T_Lebda@dlc.dqe.com 

Ionizing  Radiation  Dosimetry 

Accreditation  Valid  Through:  September  30,  1999 

This  facility  has  been  evaluated  and  deemed  competent  to 
process  the  radiation  dosimeter  listed  below  through 
employing  a  Panasonic  automatic  reader  model  UD710A. 

This  facility  is  accredited  to  process  the  following 
dosimeter  by  virtue  of  actual  demonstration  of  compliance 
with  ANSI  HPS  N  13.1 1-1993  through  testing. 

Panasonic  TLD  model  UD812-AS2  for  ANSI-N13.1 1 
categories  I,  II,  IIIA,  IIIB,  IV,  VA,  VB,  VC,  VI,  VII. 

The  dosimeter  is  housed  in  a  custom  made  plastic  clam 
shell  type  holder  with  filtering  of  4mg/cm2  mylar  over 


elements  1  &  2,  140  mg/cm2  plastic  over  element  3,  and 
840  mg/cm2  plastic  over  element  4. 

Rados  RAD-51R  Electronic  Dosimeter  for  ANSI  N13.1 1 
categories  IIIB  and  IV. 

NVLAP  LAB  CODE  100524-0 
Duke  Engineering  and  Services  Environmental 
Laboratory 

580  Main  Street 

Bolton,  MA  01740-1398 

Contact:  Mr.  Edward  F.  Maher,  Sc.D 

Phone:  978-568-2522 

Fax:  978-568-2520 

E-Mail:  EHMaher@dukeengineering.com 

Ionizing  Radiation  Dosimetry 

Accreditation  Valid  Through:  September  30,  1999 

This  facility  has  been  evaluated  and  deemed  competent  to 
process  the  radiation  dosimeters  listed  below  through 
employing  a  Panasonic  automatic  reader  model  71  OA. 

This  facility  is  accredited  to  process  the  following 
dosimeters  by  virtue  of  actual  demonstration  of  compliance 
with  ANSI  HPS  N 1 3 . 1 1  - 1 993  through  testing. 

Panasonic  TLD  model  808  in  a  ISA  model  830U  holder  for 
ANSI-N13.1 1  categories  I,  II,  IIIA,  IIIB,  IV,  VA,  VB,  VC, 
VI,  VII. 

Panasonic  TLD  model  814-AS4  for  ANSI-N13.1 1 
categories  I,  II,  IIIA,  IIIB,  IV,  VA,  VB,  VC,  VI,  VII. 

Panasonic  TLD  models  UD808/UD814  combined  for 
category  VIII. 

NVLAP  LAB  CODE  100528-0 
TU  Electric-Comanche  Peak  Steam  Electric 
Station 

5  mi.  NW  Glen  Rose  off  FM  56 

P.O.  Box  1002 

Glen  Rose,  TX  76043 

Contact:  Mr.  John  R.  Curtis 

Phone:  254-897-5332 

Fax:  254-897-0972 

E-Mail:  jcurtis@tuelectric.com 

Ionizing  Radiation  Dosimetry 

Accreditation  Valid  Through:  June  30,  1999 

This  facility  has  been  evaluated  and  deemed  competent  to 
process  the  radiation  dosimeter  listed  below  through 
employing  a  Panasonic  automatic  reader  model  UD710A. 

This  facility  is  accredited  to  process  the  following 
dosimeters  by  virtue  of  actual  demonstration  of  compliance 


NVLAP  1999  DIRECTORY  -  Page  D45 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


with  ANSI  HPS  N13.1  1-1993  through  testing. 

Panasonic  TLD  model  UD802-AT  in  an  ISA  810  holder 
with  Mylar-window  for  ANSI-N13.1 1  categories  IIIB,  IV, 
VB,  VI,  VII,  VIII. 

NVLAP  LAB  CODE  100529-0 
Detroit  Edison,  Fermi  2  Dosimetry  Laboratory 

6400  North  Dixie  Highway,  100  AIB 

Newport,  MI  48166 

Contact:  Mr.  Ronald  Gillmore 

Phone:  734-586-1388 

Fax:  734-586-1041 

E-Mail:  gillmorer@dteenergy.com 

Ionizing  Radiation  Dosimetry 

Accreditation  Valid  Through:  September  30,  1999 

This  facility  has  been  evaluated  and  deemed  competent  to 
process  the  radiation  dosimeter  listed  below  through 
employing  a  Panasonic  automatic  reader  model  UD710A. 

This  facility  is  accredited  to  process  the  following 
dosimeter  by  virtue  of  actual  demonstration  of  compliance 
with  ANSI  HPS-N13.1  1-1993  through  testing. 

Panasonic  TLD  model  UD802-AS  in  an  ISA-820  holder 
for  ANSI-N 1 3 . 1 1  categories  I,  II,  III  A,  I V,  VC,  VI,  VII, 
VIII. 

NVLAP  LAB  CODE  100535-0 
Entergy  Operations,  Inc. 

Waterford  3,  Hwy.  1 8,  River  Road 
Taft,  LA  70066 

Contact:  Mr.  Ronald  C.  McLendon 
Phone:  504-464-3199 
Fax:  504-464-3151 


Ionizing  Radiation  Dosimetry 

Accreditation  Valid  Through:  December  31,  1999 

This  facility  has  been  evaluated  and  deemed  competent  to 
process  the  radiation  dosimeter  listed  below  through 
employing  a  Panasonic  automatic  reader  model  UD710A. 

This  facility  is  accredited  to  process  the  following 
dosimeter  by  virtue  of  actual  demonstration  of  compliance 
with  ANSI  HPS  N13.1  1-1993  through  testing. 

Panasonic  TLD  model  UD802-AS  in  a  Panasonic  874A 
holder  for  ANSI-N13.il  categories  I,  II,  IIIA,  IV,  VC,  VI, 
VII,  VIII. 


NVLAP  LAB  CODE  100536-0 
Arizona  Public  Service  Co.,  Palo  Verde  Nuclear 
Generating  Station 

5801  S.  Wintersburg  Road,  Station  6107 

Tonopah,  AZ  85354-7529 

Contact:  Mr.  Michael  W.  Lantz 

Phone:  602-393-5200 

Fax:  602-393-5003 

E-Mail:  mlantz@apsc.com 

URL:  http://www.apsc.com/dosim.asp 

Ionizing  Radiation  Dosimetry 

Accreditation  Valid  Through:  September  30,  1999 

This  facility  has  been  evaluated  and  deemed  competent  to 
process  the  radiation  dosimeters  listed  below  through 
employing  a  Panasonic  automatic  reader  model  UD710A. 

This  facility  is  accredited  to  process  the  following 
dosimeters  by  virtue  of  actual  demonstration  of  compliance 
with  ANSI  HPS  Nl  3.1  1-1993  through  testing. 

Panasonic  TLD  model  UD812-AS5  in  an  ISA  holder  with 
an  open  window  over  element  1  for  ANSI-N  13.1 1 
categories  I,  II,  IIIB,  IV,  VC,  VI,  VII. 

Panasonic  TLD  combination  UD809/UD812-AS  in  a 
Panasonic  UD885A-T  holder  for  ANSI-N  13.1 1  category 
VIII. 

Panasonic  TLD  model  UD812-AS5  in  a  single  use  holder 
for  ANSI-N13.il  categories  I,  II,  IIIB,  IV,  VC,  VI,  VII. 

Panasonic  TLD  model  UD809AS/UD812  combination  in  a 
single  use  holder  for  ANSI-N  13.1 1  categories  VIII. 

Merlin  Gerlin  DMC-100  Electronic  Personnel  Dosimeter 

for  ANSI-N  13.1 1  categories  IIIB,  IV,  VI.   

NVLAP  LAB  CODE  100537-0 
Pacific  Gas  &  Electric  Company,  Diablo  Canyon 
Nuclear  Power  Plant 
P.O.  Box  56 

Avila  Beach,  CA  93424 
Contact:  Mr.  Mark  O.  Somerville 
Phone:  805-545-4007 
Fax:  805-545-6645 
E-Mail:  mos3@pge.com 

Ionizing  Radiation  Dosimetry 

Accreditation  Valid  Through:  September  30,  1999 

This  facility  has  been  evaluated  and  deemed  competent  to 
process  the  radiation  dosimeters  listed  below  through 
employing  a  Panasonic  automatic  reader  model  UD710A. 

This  facility  is  accredited  to  process  the  following 


NVLAP  1999  DIRECTORY  -  Page  D46 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


dosimeters  by  virtue  of  actual  demonstration  of  compliance 
with  ANSI  HPS  N13.1 1-1993  through  testing. 

Panasonic  TLD  model  UD802-AS  in  a  Panasonic 
UD875AT  holder  for  ANSI-N13.1 1  categories  II,  IIIA,  IV, 
VA,  VI,  VII,  VIII. 

Combination  Panasonic  TLD  model  UD813-AS8  in  a 
Panasonic  UD885AT  holder  for  ANSI-N13.1 1  category 
VIII. 


Panasonic  Model  UD802AS  in  a  Panasonic  UD-874A-T 
holder  for  ANSI-N13.1 1  categories  I,  II,  IIIA,  IV,  VA,  VB, 

VC,  VI,  VII,  VIII.   

NVLAP  LAB  CODE  100540-0 
Northeast  Utilities  Dosimetry  Laboratory 
3333  Berlin  Turnpike 
Newington,  CT  06111 
Contact:  Mr.  Charles  R.  Palmer 
Phone:  860-447-1791 
Fax:  860-444-5640 

E-Mail:  PALMECR@GWSMTP.NU.COM 


NVLAP  LAB  CODE  100538-0 
Con  Edison,  Indian  Point 

Broadway  and  Bleakley  Avenue 

Buchanan,  NY  10511-1099 

Contact:  Mr.  Richard  J.  Martucci 

Phone:  914-271-7118 

Fax:  914-734-5734 

E-Mail:  martuccir@coned.com 

Ionizing  Radiation  Dosimetry 

Accreditation  Valid  Through:  June  30,  1999 

This  facility  has  been  evaluated  and  deemed  competent  to 
process  the  radiation  dosimeter  listed  below  through 
employing  a  Panasonic  automatic  reader  model  UD710A. 

This  facility  is  accredited  to  process  the  following 
dosimeter  by  virtue  of  actual  demonstration  of  compliance 
with  ANSI-HPS  N 1 3 . 1  1  - 1 993  through  testing. 

Panasonic  TLD  model  UD802-AT  in  an  874  AT  holder  for 
ANSI-N13.1 1  categories  I,  II,  HIB,  IV,  VC,  VI,  VII,  VIII. 

NVLAP  LAB  CODE  100539-0 
U.S.  Army  Radiation  Standards  &  Dosimetry 
Laboratory 

Attn:  AMSAM-TMD-SR-D,  Bldg.  5417 

Redstone  Arsenal,  AL  35898-5000 

Contact:  Mr.  Patrick  Kuykendall 

Phone:  256-876-3340 

Fax:  256-955-6413 

E-Mail:  pkuyken@redstone.army.mil 

Ionizing  Radiation  Dosimetry 

Accreditation  Valid  Through:  December  31,  1999 

This  facility  has  been  evaluated  and  deemed  competent  to 
process  the  radiation  dosimeter  listed  below  through 
employing  a  Panasonic  Model  710  reader. 


Ionizing  Radiation  Dosimetry 

Accreditation  Valid  Through:  December  31,  1999 

This  facility  has  been  evaluated  and  deemed  competent  to 
process  the  radiation  dosimeter  listed  below  through 
employing  a  Harshaw  model  8800  TLD  workstation. 

This  facility  is  accredited  to  process  the  following 
dosimeter  by  virtue  of  actual  demonstration  of  compliance 
with  ANSI  HPS  Nl 3.1 1-1993  through  testing. 

Harshaw  TLD  card  model  8801N  (3  TLD  700,  1  TLD  600 
chips)  in  a  Harshaw  Model  8810  holder  for  ANSI-N13.1 1 

categories  I,  II,  HIB,  IV,  VB,  VI,  VII,  and  VIII.  

NVLAP  LAB  CODE  100541-0 
ComEd  -  TLD  Processing  Lab  -  CTEAM  Facility 
555  South  Joliet  Road 
Bolingbrook,  IL  60440 
Contact:  Mr.  Frank  Rescek 
Phone:  630-663-3850 
Fax:  630-663-3855 
E-Mail:  Frank  Rescek@USCM.com 

Ionizing  Radiation  Dosimetry 

Accreditation  Valid  Through:  December  31,  1999 

This  facility  has  been  evaluated  and  deemed  competent  to 
process  the  radiation  dosimeter  listed  below  through 
employing  a  Panasonic  automatic  reader  model  UD710A. 

This  facility  is  accredited  to  process  the  following 
dosimeter  by  virtue  of  actual  demonstration  of  compliance 
with  ANSI  HPS  N13.ll -1993  through  testing. 

Panasonic  TLD  model  UD802AS  in  a  UD874-T  hanger  for 
ANSI-N13.1 1  categories  I,  II,  IIIA,  IV,  VC,  VI,  VII,  VIII. 


This  facility  is  accredited  to  process  the  following 
dosimeter  by  virtue  of  actual  demonstration  of  compliance 
with  ANSI  HPS  N  13.1 1-1993  through  testing. 


NVLAP  1999  DIRECTORY  -  Page  D47 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  100544-0 
Florida  Power  &  Light  Company 

700  Universe  Blvd. 

P.O.  Box  14000 

Juno  Beach,  FL  33408-0420 

Contact:  Mr.  Joseph  Danek 

Phone:  561-694-4213 

Fax:  561-694-3706 

E-Mail:  joe_danek@email.fpl.com 

Ionizing  Radiation  Dosimetry 

Accreditation  Valid  Through:  June  30,  1999 

This  facility  has  been  evaluated  and  deemed  competent  to 
process  the  radiation  dosimeter  listed  below  through 
employing  a  Panasonic  automatic  reader  model  UD716. 

This  facility  is  accredited  to  process  the  following 
dosimeter  by  virtue  of  actual  demonstration  of  compliance 
with  ANSI-N 13. 1  1-1993  through  testing. 

Panasonic  TLD  model  UD802-AT  or  AS  in  a  ISA  820 
holder  for  ANSI-N  13.11  categories  I,  II,  IIIB,  IV,  VC,  VI, 
VII,  VIII. 


NVLAP  LAB  CODE  100548-0 
US  Air  Force  Center  for  Radiation  Dosimetry 

2402  E.  Drive 

Brooks  AFB,  TX  78235-51  14 
Contact:  Dr.  David  N.  Erwin 
Phone:  210-536-2003 
Fax:  210-536-2025 

E-Mail:  David.Erwin@Guardian.Brooks.AF.MIL 
URL:  http://www.brooks.af.mil/AL/OE/OEBD/oebd.htm 

Ionizing  Radiation  Dosimetry 

Accreditation  Valid  Through:  March  31,  1999 

This  facility  has  been  evaluated  and  deemed  competent  to 
process  the  radiation  dosimeter  listed  below  through 
employing  a  Panasonic  automatic  reader  model 
UD716AGL. 

This  facility  is  accredited  to  process  the  following 
dosimeter  by  virtue  of  actual  demonstration  of  compliance 
with  ANSI  HPS  Nl 3.1 1-1993  through  testing. 

Panasonic  TLD  model  UD802AT  in  model  820-C  hanger 
for  ANSI-N  13.1 1  categories  I,  II,  IIIA,  IV,  VC,  VI,  VII, 
VIII. 

Panasonic  TLD  model  UD802AT  in  ISA  model  822 
neutron  hanger  for  ANSI-N  13. 1 1  categories  IV,  VIII. 


NVLAP  LAB  CODE  100551-0 
Georgia  Power  Company/Enviro.  Affairs,  Enviro. 
Lab-Dosimetry 

5131  ManerRoad 
Smyrna,  GA  30080-7321 
Contact:  Mr.  Michael  C.  Nichols 
Phone:  404-799-2112 
Fax:  404-799-2141 

E-Mail:  Michael.C.NICHOLS@GPC.COM 

Ionizing  Radiation  Dosimetry 

Accreditation  Valid  Through:  March  31,  1999 

This  facility  has  been  evaluated  and  deemed  competent  to 
process  the  radiation  dosimeters  listed  below  through 
employing  Panasonic  automatic  readers  model  UD-710A 
andUD-717. 

This  facility  is  accredited  to  process  the  following 
dosimeter  by  virtue  of  actual  demonstration  of  compliance 
with  ANSI  HPS  N13. 11-1993  and  ANSI  HPSN13.32 
through  testing. 

Panasonic  TLD  model  UD802-AS  in  a  Panasonic  854A  or 
UD-874ATM1  (closed)  hanger  for  ANSI  HPS  N  13.1 1 
categories  II,  IIIB,  IV,  VC,  VI,  VII,  VIII. 

Panasonic  extremity  TLD  model  UD-817  in  an  elastic  ring 
holder  for  ANSI  HPS  Nl  3.32-1995  (NIST  Handbook 
150-4,  table  2)  categories  II,  IV  and  VII. 

NVLAP  LAB  CODE  100554-0 

PP&L,  Inc. 

Two  North  Ninth  Street 
Allentown,  PA  18101-1179 
Contact:  Mr.  Stephen  L.  Ingram 
Phone:  610-774-5412 
Fax:  610-774-7205 
E-Mail:  slingram@papl.com 

Ionizing  Radiation  Dosimetry 

Accreditation  Valid  Through:  March  31,  1999 

This  facility  has  been  evaluated  and  deemed  competent  to 
process  the  radiation  dosimeter  listed  below  through 
employing  a  Panasonic  automatic  reader  model  UD710A. 

This  facility  is  accredited  to  process  the  following 
dosimeter  by  virtue  of  actual  demonstration  of  compliance 
with  ANSI  HPS  N 1 3 . 1 1  - 1 993  through  testing. 

Panasonic  TLD  model  UD802-AS  in  a  Panasonic 
UD874-AT1  or  UD874-ATM1  hanger  for  ANSI-N13.1 1 
categories  I,  II,  IIIB,  IV,  VC,  VI,  VII,  VIII. 


NVLAP  1999  DIRECTORY  -  Page  D48  (See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  100555-0 
ICN  Dosimetry  Service,  Div.  of  ICN  Biomedicals, 
Inc. 

3300  Hyland  Ave.,  ICN  Plaza 
Costa  Mesa,  CA  92626 
Contact:  Ms.  Sandra  Nemecek 
Phone:  714-545-0100  x2297 
Fax:  714-668-3149 
E-Mail:  smnemecek@icnpharm.com 
URL:  http://www.dosimerry.com 

Ionizing  Radiation  Dosimetry 

Accreditation  Valid  Through:  June  30,  1999 

This  facility  has  been  evaluated  and  deemed  competent  to 
process  the  radiation  dosimeters  listed  below  through 
employing  the  TLD  automatic  readers:  Panasonic  model 
UD710A,  SLD  STI  model  8800,  and  Harshaw  model  6600. 
In  addition,  the  TLD  manual  readers:  Panasonic  model 
UD702  and  Harshaw  model  3500.  The  MacBeth  TD932 
densitometer,  and  a  custom  automatic  developer  and 
densitometer  for  film  processing. 

This  facility  is  accredited  to  process  the  following 
dosimeters  by  virtue  of  actual  demonstration  of  compliance 
with  ANSI  HPS  Nl 3.1  1-1993  through  testing. 

Panasonic  TLD  model  ICN  UD-802  with  a  model  UD-854 
or  UD-874  hanger  for  ANSI-N13. 1 1  categories  I,  II,  III  A, 
IV,  VC,  VI,  VII,  VIII. 

ICN  Film  Badge  (Kodak  Type  4)  for  ANSI-N  13.11 
categories  I,  II,  IIIA,  IV,  VA,  VI,  VII. 

ICN  Film  Badge  (Kodak  Type  4  with  CR39)  for 
ANSI-N13.il  category  VIII. 

Panasonic  TLD  model  UD-802  with  CR39  in  a  model 
UD-874  hanger  for  ANSI-N  13.1 1  category  VIII. 

ICN  Remtrack  (Harshaw)  TLD  model  100  enclosed  in  a 
laminated  polyethylene  material  holder  for  ANSI  N13.ll 
category  II  and  IV. 

HLD-100  for  ANSI-N13.il  categories  I,  II,  IIIA,  IV,  VA, 
VI,  VII. 

HLD-760  for  ANSI-N  13. 1 1  categories  I,  II,  IIIA,  IV,  VC, 
VI,  VII,  VIII. 

HLD-760  plus  CR39  for  ANSI-N  13.1 1  category  VIII  based 
on  equivalence 

This  facility  has  been  accredited  to  process  the  extremity 
dosimeters  listed  below  by  virtue  of  actual  demonstration 
of  compliance  with  ANSI-N13.32-1995  and  NIST 


Handbook  150-4,  Page  14,  Table  2  categories. 

Panasonic  extremity  TLD  UD-807  in  flex  ring  holder, 
based  on  testing  for  categories  IVA,  VA,  and  VB. 

HLD-100  (Wrist),  based  on  technical  equivalence,  for 
categories  I,  II  IIIA,  IIIB,  IV,  VA,  VI,  VII. 

HLD-760  (Wrist),  based  on  technical  equivalence,  for 
categories  I,  II,  IIIA,  IIIB,  IV,  VA,  VI,  VII. 

HLD-100  (Ring),  based  on  testing,  for  categories  I,  II,  IIIA, 
IV,  VA,  VB,  and  VD. 

HLD-100  1C  (Ring),  based  on  technical  equivalence,  for 
categories  I,  II,  IIIA,  IV,  VA,  VB,  VI). 

NVLAP  LAB  CODE  100556-0 
Atomic  Energy  Industrial  Laboratory  of  the 
Southwest,  Inc. 
9261  Kirby  Drive 
Houston,  TX  77054-2514 
Contact:  Mr.  Steven  H.  Allen 
Phone:  713-790-9719 
Fax:  713-790-0542 
E-Mail:  shallen@wt.net 
URL:  http://www.aeil.com 

Ionizing  Radiation  Dosimetry 

Accreditation  Valid  Through:  September  30,  1999 

This  facility  has  been  evaluated  and  deemed  competent  to 
process  the  radiation  dosimeter  listed  below  through 
employing  film  processing  using  a  computerized  custom 
densitometer. 

This  facility  is  accredited  to  process  the  following 
dosimeter  by  virtue  of  actual  demonstration  of  compliance 
with  ANSI  HPS  N 1 3 . 1 1  - 1 993  through  testing. 

Film  Badge  B-4  (Kodak  Type  2)  for  ANSI-N  1 3 . 1 1 
categories  I,  II,  IIIA,  IV,  VC,  VI,  VII. 

Film  Badge  N-5  (Kodak  Type  2  and  A)  for  ANSI-N  13.1 1 
category  VIII. 


NVLAP  1999  DIRECTORY  -  Page  D49 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  100559-0 
Troxler  Radiation  Monitoring  Svc.  a  div.  of 
Troxler  Elect.  Labs 

3008  Cornwallis  Road 
P.O.  Box  12057 

Research  Triangle  Park,  NC  27709 

Contact:  Mr.  Stephen  A.  Browne 

Phone:  919-549-8661 

Fax:  919-549-0761 

E-Mail:  troxrso@troxlerlabs.com 

Ionizing  Radiation  Dosimetry 

Accreditation  Valid  Through:  June  30,  1999 

This  facility  has  been  evaluated  and  deemed  competent  to 
process  the  radiation  dosimeter  listed  below  through 
employing  a  Panasonic  automatic  reader  model  UD710A. 

This  facility  is  accredited  to  process  the  following 
dosimeter  by  virtue  of  actual  demonstration  of  compliance 
with  ANSI  HPS  N  13.1  1-1993  through  testing. 

Panasonic  TLD  model  UD802  with  model  UD854  hanger 
for  ANSI-N  13.1 1  category  I,  II,  IIIA,  IV,  VC,  VI,  VII, 
VIIIA. 

NVLAP  LAB  (  ODE  100560-0 
Electric  Boat  Corp/A  General  Dynamics  Co. 
Radiological  Ctrl.  Dept 

75  Eastern  Point  Road 

Groton,  CT  06340-4909 

Contact:  Mr.  Robert  D.  Renza 

Phone:  860-433-3674 

Fax:  860-433-0946 

E-Mail:  rrenza@ebmail.gdeb.com 

Ionizing  Radiation  Dosimetry 

Accreditation  Valid  Through:  March  31,  1999 

This  facility  has  been  evaluated  and  deemed  competent  to 
process  the  radiation  dosimeter  listed  below  through 
employing  a  Harshaw  manual  reader  model  4000. 

This  facility  is  accredited  to  process  the  following 
dosimeter  by  virtue  of  actual  demonstration  of  compliance 
with  ANSI  HPS  N 1 3 . 1 1  - 1 993  through  testing. 

A  Harshaw  TLD  model  4040,  CaF2  Bulb  Dosimeter  for 
ANSI  HPS  N13.ll  Category  IV. 


NVLAP  LAB  CODE  100561-0 
Newport  News  Shipbuilding  Radiological  Control 
Department 

4101  Washington  Avenue 
Newport  News,  VA  23607-2770 
Contact:  Mr.  C.  W.  Amos 
Phone:  757-380-2369 
Fax:  757-380-3778 


Ionizing  Radiation  Dosimetry 

Accreditation  Valid  Through:  March  31,  1999 

This  facility  has  been  evaluated  and  deemed  competent  to 
process  the  radiation  dosimeter  listed  below  through 
employing  a  Harshaw  automatic  reader  model  8800. 

This  facility  is  accredited  to  process  the  following 
dosimeter  by  virtue  of  actual  demonstration  of  compliance 
with  ANSI  HPS  N  13.1  1-1993  through  testing. 

Harshaw  TLD  model  2276-L,  BG  (2  TLD  700, 1  TLD  600) 
in  a  Type  80  Harshaw  cardholder  for  ANSI  HPS  N13.1 1 
category  IV. 

NVLAP  LAB  CODE  100562-0 
Radiation  Laboratory,  Taiwan  Power  Company 

P.O.  Box  7 

Shihmen,  Taipei  25302 
TAIWAN 

Contact:  Mr.  W.  W.  Yeh 

Phone:  +886-2-2638-1397 

Fax:  +886-2-2638-2446 

E-Mail:  u706667@taipower.com.tw 

Ionizing  Radiation  Dosimetry 

Accreditation  Valid  Through:  September  30,  1999 

This  facility  has  been  evaluated  and  deemed  competent  to 
process  the  radiation  dosimeters  listed  below  through 
employing  a  Panasonic  automatic  reader  model  UD710A. 

This  facility  is  accredited  to  process  the  following 
dosimeters  by  virtue  of  actual  demonstration  of  compliance 
with  ANSI  HPS  N  13.1  1-1993  through  testing. 

Panasonic  TLD  model  UD802AS  in  a  UD-874A  holder  for 
ANSI-N13.il  categories  I,  II,  IIIA,  IV,  VA,  VI,  VII,  VIII. 


NVLAP  1999  DIRECTORY  -  Page  D50 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  100563-0 
Combustion  Engineering,  Inc. 

2000  Day  Hill  Road,  Dept.  9459-0202 

P.O.  Box  500 

Windsor,  CT  06095-0500 

Contact:  Mr.  Stephen  M.  Sorensen 

Phone:  860-285-5285 

Fax:  860-285-2540 


Ionizing  Radiation  Dosimetry 

Accreditation  Valid  Through:  September  30,  1999 

This  facility  has  been  evaluated  and  deemed  competent  to 
process  the  radiation  dosimeter  listed  below  through 
employing  a  Panasonic  automatic  reader  model  UD710A. 

This  facility  is  accredited  to  process  the  following 
dosimeter  by  virtue  of  actual  demonstration  of  compliance 
with  ANSI  HPS-N 1 3 . 1 1  - 1 993  through  testing. 

Panasonic  TLD  model  UD802-AS2  in  a  Panasonic 
UD874-AT  holder  for  ANSI-N13.1 1  categories  II,  IV,  VC, 

VII.  

NVLAP  LAB  CODE  100565-0 
Naval  Nuclear  Propulsion  Program  Directorate, 
Washington,  D.C. 
Puget  Sound  Naval  Shipyard,  Rad.  Hlth 
Division,  Code  105.5,  1400  Farragut  Ave 
Bremerton,  WA  98314-5000 
Contact:  Mr.  R.  K.  Alspach 
Phone:  360-476-3596 
Fax:  360-476-4383 


Ionizing  Radiation  Dosimetry 

Accreditation  Valid  Through:  March  31,  1999 

The  facility  listed  has  been  evaluated  as  a  representative 
site  and  deemed  competent  to  process  the  radiation 
dosimeter  listed  below  through  employing  a  Radiac 
Computer-Indicator  Model  No.  CP-1 1 12/PD  TLD  reader. 

This  facility  is  accredited  to  process  the  following 
dosimeter  by  virtue  of  actual  demonstration  of  compliance 
with  ANSI  HPS  Nl  3. 1 1  -1 993  through  testing: 

CaF  Bulb  Dosimeter  (DT-526/PD)  for  ANSI-N13.il 
categories  II,  IV. 

The  accreditation  is  also  extended  to  include  processing 
performed  by  other  facilities  in  the  Naval  Nuclear 
Propulsion  Program  which  use  identical  equipment  and 
procedures  as  listed  above. 


NVLAP  LAB  CODE  100567-0 

HPNW 

1  1535  S.W.  67th 
Tigard,  OR  97223-8504 
Contact:  Mr.  Ross  L.  Mercer 
Phone:  503-620-6617 
Fax:  503-684-5548 
E-Mail:  Ross@HPNW.com 

Ionizing  Radiation  Dosimetry 

Accreditation  Valid  Through:  June  30,  1999 

This  facility  has  been  evaluated  and  deemed  competent  to 
process  the  radiation  dosimeter  listed  below  through 
employing  a  Panasonic  automatic  reader  model  UD716  and 
the  Harshaw  4400C  for  extremity  processing. 

This  facility  is  accredited  to  process  the  following 
dosimeters  by  virtue  of  actual  demonstration  of  compliance 
with  ANSI-HPS  N13.1 1-1993  through  testing. 

Panasonic  TLD  model  UD802-AT2  in  a  ISA  83 1U  holder 
for  ANSI-N13.1 1  categories  I,  II,  IIIA,  IV,  VA,  VI,  VII 
and  VIII. 

This  facility  is  accredited  to  process  the  Harshaw  extremity 
TLD  model  100  in  a  HPNW  design  ring  holder  for  HPS 
ANSI-N13.32  (NIST  Handbook  150-4,  table  2)  categories 
I,  II,  IIIA,  IV,  VC,  VI,  VII.  

NVLAP  LAB  CODE  100570-0 

Clinton  Power  Station 

6  mi.  East  of  Clinton,  Route  54  East 

P.O.  Box  678 

Clinton,  IL  61727-0678 

Contact:  Ms.  Mary  J.  Lewis 

Phone:  217-935-8881  x3718 

Fax:  217-935-4934 

E-Mail:  mary_lewis@illinova.com 

Ionizing  Radiation  Dosimetry 

Accreditation  Valid  Through:  December  31,  1999 

This  facility  has  been  evaluated  and  deemed  competent  to 
process  the  radiation  dosimeter  listed  below  through 
employing  a  Panasonic  Model  UD716AGL  automatic 
reader. 

This  facility  is  accredited  to  process  the  following 
dosimeter  by  virtue  of  actual  demonstration  of  compliance 
with  ANSI  HPS  Nl 3.1 1-1993  through  testing. 

Panasonic  TLD  model  UD-802-AT  in  a  ISA  model  820 
holder  for  ANSI-N13.il  categories  I,  II,  IIIA,  IV,  VC,  VI, 
VII,  VIII. 


NVLAP  1999  DIRECTORY  -  Page  D51 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  100571-0 
United  States  Dosimetry  Technology,  Inc. 

660-A  George  Washington  Way 

Richland,  WA  99352-4246 

Contact:  Mr.  M.  K.  Winegardner 

Phone:  509-946-8738 

Fax:  509-943-2710 

E-Mail:  mk_wine@compuserve.com 

URL:  http://vvrww.usdt.com 

Ionizing  Radiation  Dosimetry 

Accreditation  Valid  Through:  December  31,  1999 

This  facility  has  been  evaluated  and  deemed  competent  to 
process  the  radiation  dosimeters  listed  below  through 
employing  a  USDT  TLD  Card  Reader  and  a  USDT  film 
densitometer. 

This  facility  is  accredited  to  process  the  following 
dosimeters  by  virtue  of  actual  demonstration  of  compliance 
with  ANSI  HPS  N 1 3 . 1 1  - 1 993  through  testing. 

USDT  TLD  F  (TLD-700  and  600)  for  ANSI-N13.1 1 
categories  I,  II,  IIIA,  IV,  VA,  VI,  VII,  VIII. 

USDT  T-3  Kodak  type  2  film  for  ANSI- 13. 1 1  categories  I, 
II,  IIIA,  IV,  VA,  VI,  VII. 

NVLAP  LAB  CODE  100573-0 

Proxtronics,  Inc. 

5795-B  Burke  Centre  Parkway 

P.O.  Box  12150 

Burke,  V A  22015 

Contact:  Mr.  W.  Guy  Davis 

Phone:  703-425-4811 

Fax:  703-503-2856 

E-Mail:  sales@Proxtronics.com 

URL:  http://www.proxtronics.com 

Ionizing  Radiation  Dosimetry 

Accreditation  Valid  Through:  June  30,  1999 

This  facility  has  been  evaluated  and  deemed  competent  to 
process  the  radiation  dosimeter  listed  below  through 
employing  film  processing  using  a  Victoreen  07-440 
densitometer  and  TLD  processing  using  a  Panasonic 
UD710A. 

This  facility  is  accredited  to  process  the  following 
dosimeter  by  virtue  of  actual  demonstration  of  compliance 
with  ANSI  HPS  Nl 3.1  1-1993  through  testing. 

Film  Badge  (Kodak  Type  II)  for  ANSI  N13.ll  categories 
III  &  IV. 

Panasonic  TLD  model  UD802-AS2  in  an  ISA  831  hanger 
for  ANSI  N  13.1 1  categories  I,  II,  IIIA,  IV,  VC,  VI,  VII, 
VIII. 


Panasonic  TLD  model  UD802-AS2  in  a  Panasonic  854 
hanger  for  ANSI  N13.1 1  categories  IIIA,  IV. 

NVLAP  LAB  CODE  101004-0 
Labcorp  Analytics  Laboratory 

8040  Villa  Park  Drive 
Richmond,  VA  23228 
Contact:  Mr.  James  A.  Calpin 
Phone:  804-264-7100 
Fax:  804-264-8873 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  101005-0 
Severn  Trent  Laboratories  (MA) 

149  Rangeway  Road 
N.  Billerica,  MA  01862-2097 
Contact:  Dr.  Ernest  T.  Dobi 
Phone:  978-667-1400 
Fax:  978-667-7871 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  September  30,  1999 


Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  September  30,  1999 


NVLAP  LAB  CODE  101006-0 
Advanced  Industrial  Hygiene  Services,  Inc. 

2131  S.W.  2  Ave. 
Miami,  FL  33129-1411 
Contact:  Mr.  Bruce  Marchette 
Phone:  305-854-7554 
Fax:  305-285-0677 
E-Mail:  AIHSl@AOL.COM 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  1999  DIRECTORY  -  Page  D52 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  10101 1-0 
Hygeia  Laboratories,  Inc. 

600  West  Cummings  Park,  Suite  1900 

Woburn,MA  01801-6350 

Contact:  Ms.  Diane  E.  Capen 

Phone:  781-933-5074 

Fax:  781-938-1487 

E-Mail:  Pichette64@atc-enviro.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101012-0 
Dixon  Information  Inc. 

78  West  2400  South 

South  Salt  Lake,  UT  84115-3013 

Contact:  Mr.  Willard  C.  Dixon 

Phone:  801-486-0800 

Fax:  801-486-0849 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  101014-0 
Aires  Consulting  Group,  Inc. 

1550  Hubbard 
Batavia,  IL  60510 
Contact:  Ms.  Cynthia  Darling 
Phone:  630-879-3006 
Fax:  630-879-3014 

E-Mail:  cindydarling@airesconsulting.com 
URL:  airesconsulting.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101019-0 

EA  Group 

7118  Industrial  Park  Blvd. 
Mentor,  OH  44060-5314 
Contact:  Mr.  James  D.  Hale 
Phone:  440-951-3514 
Fax:  440-951-3774 

URL:  http://www.eagroup-ohio.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  101031-0 

Fiberquant,  Inc. 

5025  S.  33rd  St. 
Phoenix,  AZ  85040 
Contact:  Mr.  Larry  S.  Pierce 
Phone:  602-276-6139 
Fax:  602-276-4558 

E-Mail:  FIBERQUANT@ABILNET.COM 
URL:  http://www.fiberq.com/labs/fq.htm 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101032-0 
Batta  Laboratories,  Inc. 

Delaware  Industrial  Park 

6  Garfield  Way 

Newark,  DE  19713-5817 

Contact:  Mr.  Naresh  C.  Batta 

Phone:  302-737-3376 

Fax:  302-737-5764 

E-Mail:  battaenv@battaenv.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  1999  DIRECTORY  -  Page  D53 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  101035-0 
Microbac  Laboratories,  Inc. 

Erie  Testing  Division 
1962  Wager  Road 
Erie,  PA  16509 

Contact:  Mr.  Michael  McElhinny 
Phone:  814-825-8533 
Fax:  814-825-9254 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  September  30,  1999 


NVLAP  LAB  CODE  101037-0 
Microscopic  Analysis,  Inc. 

1 1760  Westline  Industrial  Drive 
St.  Louis,  MO  63146-3402 
Contact:  Mr.  Douglas  N.  Nimmo 
Phone:  314-993-2212 
Fax:  314-993-3193 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  101039-0 
Carnow,  Conibear  &  Associates  Ltd. 

333  W.  Wacker  Drive,  Suite  1400 
Chicago, IL  60606-1226 
Contact:  Mr.  Aleksey  Torosin 
Phone:  312-782-4486 
Fax:  312-782-5145 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  September  30,  1999 


Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  September  30,  1999 


NVLAP  LAB  CODE  101045-0 
Hub  Testing  Laboratory,  Inc. 

95  Beaver  Street 

Waltham,  MA  02453-8423 

Contact:  Mr.  Frederick  T.  Boyle 

Phone:  800-878-8938 

Fax:  781-893-4414 

E-Mail:  ftboyle@ultranet.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  December  31,  1999 


NVLAP  LAB  CODE  101048-0 
EMSL  Analytical,  Inc. 

108  Haddon  Avenue 
Westmont,  NJ  08108-2799 
Contact:  Mr.  Robert  G.  Shumate,  Jr. 
Phone:  609-858-4800 
Fax:  609-858-4960 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101048-1 
EMSL  Analytical,  Inc. 

1770  The  Exchange  SE,  Suite  135 
Atlanta,  GA  30339 
Contact:  Rachel  Travis 
Phone:  770-956-9150 
Fax:  770-956-9181 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  1999  DIRECTORY  -  Page  D54 


(See  *How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  101048-2 


EMSL  Analytical,  Inc. 

1056  Stelton  Rd. 
Piscataway,  NJ  08854 
Contact:  Adrian  Arav 
Phone:  908-981-0550 
Fax:  908-981-0551 


NVLAP  LAB  CODE  101048-9 
EMSL  Analytical,  Inc. 

350  Fifth  Avenue,  15th  Floor,  Suite  1524 
New  York,  NY  10118 
Contact:  Jose  Arriaga 
Phone:  212-290-0051 
Fax:  212-290-0058 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  June  30,  1999 


Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101048-3 
EMSL  Analytical,  Inc. 

1720  South  Amphlett  Blvd.,  Suite  130 
San  Mateo,  CA  94402 
Contact:  Emmanuel  Dounias 
Phone:  650-570-5401 
Fax:  650-570-5402 


NVLAP  LAB  CODE  101048-10 
EMSL  Analytical,  Inc. 

208  Stone  Henge  Road 
Carle  Place,  NY  11514 
Contact:  Brian  Riedener 
Phone:  516-997-7251 
Fax:  516-997-7528 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  June  30,  1999 


Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101048-4 
EMSL  Analytical,  Inc. 

212  S.  Wagner  Road 
Ann  Arbor,  MI  48103 
Contact:  Hildegard  Hohnke 
Phone:  734-668-6810 
Fax:  734-668-8532 


NVLAP  LAB  CODE  101051-0 
Accredited  Environmental  Technologies,  Inc. 

28  North  Pennell  Road 
Media,  PA  19063 
Contact:  Mr.  Carl  Josephson 
Phone:  610-891-0114 
Fax:  610-891-0559 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  1999  DIRECTORY  -  Page  D55 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  101058-0 
Waste  Management  Federal  Services  of  Hanford, 
Inc. 

Waste  Sampling  &  Characterization  Fac. 

P.O.  Box  700  MSIN:  S3-30 

Richland,  WA  99352 

Contact:  Ms.  Maureen  K.  Hamilton 

Phone:  509-373-7167 

Fax:  509-373-7133 

E-Mail:  maureen  k  hamilton@rl.gov 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  101060-0 
DLZ  Laboratories,  Inc. 

6121  Huntley  Road 

Columbus,  OH  43229-1003 

Contact:  Mr.  Michael  R.  Pannell 

Phone:  614-848-4333 

Fax:  614-841-0818 

E-Mail:  dlzlabs@iwaynet.net 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101064  0 
ECS/Wagner  Environmental 

371  West  5th  Avenue 
Eugene,  OR  97401 
Contact:  Mr.Ms  Les  Lyons 
Phone:  541-343-0300 
Fax:  541-343-0375 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  101066-0 
Law  Engineering  and  Environmental  Services, 
Inc. 

2100  Riverchase  Center,  Suite  450 
Birmingham,  AL  35244 
Contact:  Mr.  James  C.  Findlay 
Phone:  205-733-7672 
Fax:  205-985-2951 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  101061-0 

ChemScope,  Inc. 

15  Moulthrop  Street 
North  Haven,  CT  06473-3686 
Contact:  Mr.  Ronald  D.  Arena 
Phone:  203-865-5605 
Fax:  203-498-1610 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  101070-0 

PSI,  Inc. 

25  Dubon  Court 

Farmingdale,  NY  11735 

Contact:  Dr.  Antonio  Lanzirotti 

Phone:  516-752-1226 

Fax:  516-752-1508 

E-Mail:  ALANZIR@IDT.NET 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  101062-0 

A  T  Labs 

250  DeBartolo  PI.,  Suite  2525 

Youngstown,  OH  44512 

Contact:  Mr.  Edward  B.  Engel 

Phone:  800-365-3396 

Fax: 330-758-1245 

E-Mail:  edengel@ix.netcom.com 

URL:  http://assaytec.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  101072-0 
Bodycote  Industrial  Testing,  Inc. 

2350  South  7th  Street 

St.  Louis,  MO  63104-4296 

Contact:  Mr.  William  J.  Lowry 

Phone:  314-771-7111 

Fax: 314-771-9573 


Fasteners  &  Metals 

Accreditation  Valid  Through:  June  30,  1999 

NVLAP 

Code  Designation 
Chemical  Analysis 


NVLAP  1999  DIRECTORY  -  Page  D56 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Combustion  analysis  for  carbon,  sulfur,  oxygen, 

nitrogen,  and  hydrogen 

FA/547      ASTM  E350 

Energy  dispersive  X-ray  analysis 

FA/500      ASTM  El 508 

Optical  emission  spectrochemical  analysis 

FA/457      ASTM  E4 15 

Solution  chemical  analysis 

FA/448       ASTM  E350 

Mechanical  and  Physical  Testing  and  Inspection 

Adhesion  of  metallic  coatings  on  fasteners 

FA/143  ASTMB571 

FA/541       QQ-P-416  Sec.  4.6.2 

Axial  tensile  strength  of full-size  threaded  fasteners 

FA/266      ASTM  F606  Sec.  3.4.1-3.4.3 

Bend  test  of  full  size  eyebolts 

FA/147      ASTM  F541 

Breaking  strength  of  fullsize  eyebolts 

FA/275       ASTM  A489 

Brinell  hardness  of  fasteners 

FA/185       ASTM  A370  Sec.  16 

Charpy  impact  (u-notch)  testing 

FA/517  ASTME23 

Charpy  impact  (v-notch)  testing 

FA/211       ASTM  A370  Sec.  19-28 

FA/212  ASTME23 

Copper  sulfate  test  -  test  for  free  iron  on  the  surface  of 

corrosion  resistant  fasteners 

FA/545       ASTM  A262  Sec.  22-3 1 

Double  shear  of  externally  threaded  fasteners 

FA/257  MIL-STD-1312-13 

Elevated  temperature  testing  capability 

FA/546  ASTME21 

Humidity  testing  of  fasteners 

FA/548      ASTM  D2247 

Hydrogen  embrittlement  (stress  durability)  of  externally 

threaded  fasteners 

FA/549      Chrysler  PS-9500 

Intergranular  corrosion  susceptibility  in  austentic 

stainless  steel  fasteners  -  nitric  aci 

FA/1 73       ASTM  A262  Sec.  15-21,  Practice  C 

Intergranular  corrosion  susceptibility  of  austentic 

stainles  steel  fasteners  -  oxalic  acid 

FA/1 74       ASTM  A262  Sec.  3-7,  Practice  A 

Magnetic  permeability 

FA/215  MIL-I-17214 

Measurement  of  fastener  coating  thickness  -  magnetic 
methods 

FA/153  ASTMB499 

Measurement  of  fastener  coating  thickness  - 

microscopical  method 

FA/160  ASTMB487 

Measurement  of  fastener  coating  thickness  -  weight  of 
coating 

FA/ 164      ASTM  A90 


Microhardness  of  fasteners 
FA/ 189      ASTM  E3 84 
Prevailing  torque 
FA/216      ANSI  B18.16.1M 
FA/217  IFI-100/107 

Proof  load  of full-size  externally  threaded  fasteners 

FA/225       ASTM  A370  Sec.  A3.2.1.1-A3.2.1.3 
FA/226       ASTM  F606  Sec.  3.2.1-3.2.3 
Proof  load  of  full-size  eyebolts 
FA/231  ASTMA489 

Proof  load  of  internally  threaded  fasteners  (nuts) 
FA/237      ASTM  F606M  Sec.  4.2 
Reusability  test  of  self-locking  internally  threaded 
fasteners 

FA/542  ANSIB18.16.1M 

FA/543  IFI-100/107 

Rockwell  hardness  of  fasteners 

FA/196      ASTM  A370  Sec.  18 

Rockwell  superficial  hardness  of  fasteners 

FA/206       ASTM  A370  Sec.  18 

Salt  spray  testing  of  fasteners 

FA/166      ASTM  Bl  17 

Single  shear  of  externally  threaded  fasteners 

FA/256  MIL-STD-1312-20 

Tension  testing  of  machined  specimens  from  externally 

threaded  fasteners 

FA/279      ASTM  F606  Sec.  3.6 

Torque-out  test 

FA/544  IFI-101 

Total  extension  at  fracture  of  externally  threaded 
fasteners 

FA/285       ASTM  F606  Sec.  3.7 

Vickers  hardness  -  test  forces  from  9.807  to  11 76  N  (1  to 
120  kgf) 

FA/507       ASTM  E384 

Wedge  tensile  strength  of full-size  threaded  fasteners 

FA/290      ASTM  F606  Sec.  3.5 

Yield  strength  of full-size  externally  threaded  fasteners 

FA/298       ASTM  F606  Sec.  3.2.4 

Metallography 

Decarburization  and  case  depth  measurement  in 
fasteners 

FA/328  SAEJ121 
FA/330       SAE  J423 
Determination  of  grain  size  of fasteners 
FA/331       ASTM  El  12 

Macroscopic  examination  of  fasteners  by  etching 

FA/484      ASTM  E3  81 

Microscopic  examination  of  fasteners  by  etching 

FA/512  ASTME407 

Surface  discontinuities  of  externally  threaded  fasteners 

FA/361       SAE  J 123 

Surface  discontinuities  of  internally  threaded  fasteners 
FA/365  SAEJ122 
Nondestructive  Inspection 


NVLAP  1999  DIRECTORY  -  Page  D57 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Liquid  penetrant  inspection  of fasteners 
FA/372       SAE  J426 
Magnetic  particle  inspection  of  fasteners 
FA/378       SAE  J420 

NVLAP  LAB  CODE  101079-0 
Wausau  Insurance  Companies 

Environmental  Health  Laboratory 

P.O.  Box  8017,  2000  Westwood  Drive 

Wausau,  WI  54402-8017 

Contact:  Dr.  Thomas  Stavros 

Phone:  715-842-6810 

Fax:  715-847-8391 

E-Mail:  tstavros@wausau.com 

Bulk  Asbestos  Analysis  (PLM) 
Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101086-0 
Analytica  Solutions,  Inc. 

325  Interlocken  Parkway,  Suite  200 
Broomfield,  CO  80021 
Contact:  Mr.  Tim  Osbourn 
Phone:  303-469-8868 
Fax:  303-469-5254 

E-Mail:  Marketing@Analyticagroup.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  101087-0 
Environmental  Monitoring  &  Consulting 
Associates 

P.O.  Box  872 
Somerville,  NJ  08876 
Contact:  Mr.  Joel  Russell 
Phone:  732-249-3005 
Fax:  732-249-3384 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  December  3 1 ,  1999 


NVLAP  LAB  CODE  101088-0 

EEC,  Inc. 

107  Wind  Chime  Court 
Raleigh,  NC  27615 
Contact:  Mr.  Mike  Shrimanker 
Phone:  919-846-1016 
Fax:  919-846-1813 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101091-0 
Maxim  Technologies,  Inc. 

2342  Fabens 
P.O.  Box  59902 
Dallas,  TX  75229-3399 
Contact:  Ms.  Joyce  Eckles 
Phone:  214-631-2700 
Fax:  214-920-1891 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  June  30,  1999 

NVLAP  LAB  CODE  101091-1 
Maxim  Technologies,  Inc. 

222  Cavalcade  Street 
P.O.  Box  8768 
Houston,  TX  77249-8768 
Contact:  Heidi  Foltz 
Phone:  713-692-9151 
Fax:  713-696-6307 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101103-0 
Chatfield  Technical  Consulting  Limited 

2071  Dickson  Road 
Mississauga  Ontario  L5B  1Y8 
CANADA 

Contact:  Dr.  Eric  J.  Chatfield 
Phone:  905-896-7611 
Fax:  905-896-1930 
E-Mail:  chatfiel@echo-on.net 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  101106-0 
Clayton  Environmental  Consultants 

a  division  of  Clayton  Group  Srvs.,  Inc. 
4636  East  Marginal  Way  South,  Suite  215 
Seattle,  WA  98134-2331 
Contact:  Ms.  Patricia  Lukens 
Phone:  206-763-7364 
Fax:  206-763-4189 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  1999  DIRECTORY  -  Page  D58 


(See  'How  To  Use  This  Directory*  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  101109-0 
Wisconsin  Occupational  Health  Laboratory 

2601  Agriculture  Drive 
P.O.  Box  7996 
Madison,  WI  53707-7996 
Contact:  Mr.  Lyle  Reichmann 
Phone:  608-224-6221 
Fax:  608-224-6213 

E-Mail:  LR@WOHL.SLH.WISC.EDU 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101111-0 
City  of  Los  Angeles  Department  of  Water  and 
Power 

Department  of  Water  and  Power 

PO  Box  51  111,  1630  N.  Main  St.,  Bldg.  7 

Los  Angeles,  CA  90051-0100 

Contact:  Mr.  Timothy  B.  Hemming 

Phone:  213-367-7271 

Fax:  213-367-7285 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  101125-0 
Clayton  Laboratory  Services 

400  Chastain  Center  Blvd.,  NW 
Suite  490 

Kennesaw,  GA  30144-5558 

Contact:  Mr.  Alan  M.  Segrave 

Phone:  770-499-7500 

Fax:  770-423-4990 

E-Mail:  ASEG007@AOL.COM 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101130-0 

TEM,  Incorporated 

443  Duane  Street 
GlenEllyn,IL  60137 
Contact:  Mr.  James  Tuinenga 
Phone:  630-790-0880 
Fax: 630-790-0882 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  September  30,  1999 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  September  30,  1999 


NVLAP  LAB  CODE  101135-0 
McKee  Environmental  Health,  Inc. 

303  Westfield  Lane 
Friendswood,  TX  77546-6316 
Contact:  Mr.  Ronald  S.  McKee 
Phone:  281-482-3403 
Fax:  281-482-7203 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101136-0 
American  Medical  Laboratories,  Inc. 

14225  Newbrook  Drive 
P.O.  Box  10841 
Chantilly,  VA  20153-0841 
Contact:  Ms.  Jan  Turner 
Phone:  703-802-6900 
Fax:  703-802-7041 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  101143-0 
AMA  Analytical  Services,  Inc. 

4475  Forbes  Blvd. 

Lanham,  MD  20706 

Contact:  Mr.  Andreas  Saldivar 

Phone: 301-459-2640 

Fax:  301-459-2643 

E-Mail:  AMALAB@EROLS.COM 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101147-0 
Hygienetics  Laboratory  Services 

98  North  Washington  Street 
Boston,  MA  02114 
Contact:  Mr.  Bryan  Clark 
Phone:  617-589-0660 
Fax:  617-742-4285 
E-Mail:  lab@hygienetics.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  1999  DIRECTORY  -  Page  D59 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  101150-0 
Schneider  Laboratories,  Inc. 

2512  W.  Cary  Street 
Richmond,  VA  23220-5117 
Contact:  Mr.  Raja  F.  Abouzaki 
Phone:  804-353-6778 
Fax:  804-353-6928 
E-Mail:  s_lab@ix.netcom.com 
URL:  http://www.slabinc.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 

NVLAP  LAB  CODE  101151-0 
Micro  Analytical  Laboratories,  [nc 

3618  N.W.  97th  Blvd. 

Gainesville,  FL  32606 

Contact:  Mr.  Robert  A.  Longo 

Phone:  352-332-1701 

Fax:  352-332-3572 

E-Mail:  MALINC@MSN.COM 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 

Airboi  me  Asbestos  Analysis  (TEM) 
Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101152-0 
1  aw  Engineering  and  Environmental  Services, 
Inc. 

5500  Guhn  Road 
Houston,  TX  77040-6126 
Contact:  Mr.  Tony  T.  Dang 
Phone:  713-939-7161 
Fax:  713-462-7903 
E-Mail:  tdang@lawco.com 
URL:  http://www.lawco.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101155-0 
NATEC  International,  Inc. 

7441  Anaconda  Avenue 
Garden  Grove,  CA  92841-2911 
Contact:  Mr.  Vane  Thomas 
Phone:  714-894-7577 
Fax:  714-373-1768 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  December  31,  1999 


NVLAP  LAB  CODE  101162-0 
EcoSystems  Environmental,  Inc. 

140 8 A  Vantage  Street 
Carrollton,  TX  75006 
Contact:  Mr.  Bakhtiar  Dargali 
Phone:  972-416-0520 
Fax:  972-416-4512 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  101165-0 
International  Asbestos  Testing  Laboratory 

16000  Horizon  Way,  Unit  100 

Mt.  Laurel,  NJ  08054 

Contact:  Mr.  Frank  E.  Ehrenfeld,  III 

Phone:  609-231-9449 

Fax:  609-231-9818 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101168-0 

AAC  Trinity,  Inc. 

38855  Hills  Tech  Drive,  Suite  550 

Farmington  Hills,  MI  4833 1 

Contact:  Mr.  Charles  A.  O'Bryan 

Phone:  248-848-9656 

Fax:  248-848-9657 

E-Mail:  sales@aactrinity.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  101170-0 
Gelles  Laboratories,  Inc. 

2836  Fisher  Road 
Columbus,  OH  43204-3538 
Contact:  Dr.  Stanley  H.  Gelles 
Phone:  614-276-2957 
Fax:  614-276-3441 

E-Mail:  infol@gellab.com  or  sgelles@compuserve.com 
URL:  http://www.gellab.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  1999  DIRECTORY  -  Page  D60 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  1011 85-0 

SEAS,  Inc. 

3089  Pandapas  Pond  Road 
P.O.  Box  660 

Blacksburg,  VA  24063-0660 
Contact:  Mr.  David  L.  Violette 
Phone:  540-951-9283 
Fax: 540-951-9282 
E-Mail:  seas@swva.net 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  101187-0 

ATC  Associates,  Inc. 

104  E.  25th  Street  10th  Floor 
New  York,  NY  10010 
Contact:  Ms.  Milena  Lowd 
Phone:  212-353-8280 
Fax:  212-353-3599 

E-Mail:  Lowdl5@ATC-ENVIRO.COM 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101 188-0 
Tremco,  Inc.  -  Roofing  Division,  An  RPM 
Company 

3735  Green  Road 
Beachwood,  OH  44122 
Contact:  Mr.  Greg  Rudolph 
Phone:  216-766-5644 
Fax:  216-765-6737 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  101190-0 
Pacific  Environmental  Services,  Inc. 

560  Herndon  Parkway,  Suite  200 

Hemdon,VA  20170-5240 

Contact:  Ms.  Pamela  S.  Reuille 

Phone:  703-471-8383 

Fax:  703-481-8296 

E-Mail:  preuille@hrn.pes.com 

URL:  http://www.pes.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  101 192-0 
Philip  Environmental  Services  Corp. 

210  West  Sandbank  Road 

P.O.  Box  230 

Columbia,  IL  62236-0230 

Contact:  Mr.  Craig  M.  Brooks 

Phone:  618-281-7173 

Fax:  618-281-5120 

E-Mail:  craig_brooks@philipinc.com 

URL:  http://www.philipinc.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 

NVLAP  LAB  CODE  101 199-0 

HYGENIX,  INC. 

40  Hoyt  Street 
Stamford,  CT  06905-5616 
Contact:  Mr.  Arthur  Morris 
Phone:  203-324-2222 
Fax:  203-324-9857 

URL:  http://www.hygenix.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  December  31,  1999 

NVLAP  LAB  CODE  101202-0 
STAT  Analysis  Corporation 

2201  W.  Campbell  Park  Dr. 
Chicago,  IL  60612-3501 
Contact:  Dr.  Surendra  N.  Kumar 
Phone: 312-733-0551 
Fax:  312-733-2386 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101208-0 

RJ  Lee  Group,  Inc. 

350  Hochberg  Road 

Monroeville,  PA  15146-1516 

Contact:  Mr.  Drew  R.  Van  Orden 

Phone:  724-325-1776 

Fax:  724-733-1799 

E-Mail:  DREW@RJLG.COM 

URL:  http://www.RJLG.COM 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  1999  DIRECTORY  -  Page  D61 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  101208-2 

RJ  Lee  Group,  Inc. 

Bay  Area  Laboratory 

530  McCormick  Place 

San  Leandro,  CA  94577 

Contact:  Kyle  M.  Bishop 

Phone:  510-567-0480 

Fax:  510-567-0488 

E-Mail:  KBISHOP@RJLG.COM 

URL:  http://www.RJLG.COM 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LA  B  CODE  101208-3 

RJ  Lee  Group,  Inc. 

Manassas  Laboratory 
10503  Battleview  Parkway 
Manassas,  VA  20109 
Contact:  Monica  McCloy 
Phone:  703-368-7880 
Fax:  703-368-7761 

URL:  http://www.RJLG.COM 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  1 0 1 208-5 

RJ  Lee  Group,  Inc. 

Houston  Laboratory 

14760  Memorial  Drive,  Suite  106 

Houston,  TX  77079 

Contact:  Tony  Rease 

Phone:  281-584-0584 

Fax:  281-584-0588 

E-Mail:  RJLG01@aol.com 

URL:  http://www.RJLG.COM 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101216-0 
CTL  Environmental  Services 

24404  S.  Vermont  Avenue,  Suite  307 

Harbor  City,  CA  90710 

Contact:  Mr.  Rich  Brockbank 

Phone:  310-530-5006 

Fax: 310-530-0792 

E-Mail:  rbrockbank@ctles.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  September  30,  1999 


NVLAP  LAB  CODE  101218-0 
EMS  Laboratories,  Inc. 

1 1 7  West  Bellevue  Drive 
Pasadena,  CA  91105-2503 
Contact:  Ms.  Bernadine  M.  Kolk 
Phone:  626-568-4065 
Fax:  626-796-5282 
E-Mail:  emslab2@aol.com 
URL:  http://www.emslabs.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101221-0 

Micro  Air,  Inc. 

6320  La  Pas  Trail 

Indianapolis,  IN  46268-4104 

Contact:  Dr.  Morris  L.V.  French 

Phone:  317-293-1533 

Fax:  317-290-3566 

E-Mail:  microair@microair.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  101222-0 

Enviro-Probe,  Inc. 

2917  Bruckner  Boulevard 
Bronx,  NY  10461 
Contact:  Dr.  Ved  P.  Kukreja 
Phone:  718-863-0045 
Fax:  718-518-7454 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  December  31,  1999 


NVLAP  1999  DIRECTORY  -  Page  D62 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  101226-0 
Law  Engineering  and  Environmental  Services, 
Inc. 

2801  YorkmontRoad 
P.O.  Box  11297 
Charlotte,  NC  28220 
Contact:  Mr.  Jack  Coan 
Phone:  704-357-8600 
Fax:  704-357-8639 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101228-0 
The  Scott  Lawson  Group,  Ltd. 

29  River  Road 
P.O.  Box  3304 
Concord,  NH  03302-0894 
Contact:  Ms.  Jennifer  Scott 
Phone:  603-228-3610 
Fax:  603-228-3871 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101232-0 
ERI  Consulting  Engineers,  Inc. 

2024  Republic  Drive 

P.O.  Box  2024 

Tyler,  TX  75701-2024 

Contact:  Ms.  Kathy  R.  Schosek 

Phone:  903-534-5001 

Fax:  903-534-8701 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101233-0 

HDT  Laboratory,  Inc. 

1 00  East  NASA  Road  One,  Suite  2 1 0 
P.O.  Box  57727 
Webster,  TX  77598 
Contact:  Mr.  Jerry  W.  Bright 
Phone: 281-338-9000 
Fax: 281-338-2351 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  101234-0 
Braun  Intertec  Corporation 

6875  Washington  Avenue  South 

P.O.  Box  39108 

Minneapolis,  MN  55439-0108 

Contact:  Ms.  Beth  Regan 

Phone:  612-942-4828 

Fax:  612-942-4844 

E-Mail:  bregan@brauncorp.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101235-0 
Materials  Analytical  Services,  Inc. 

3945  Lakefield  Court 
Suwanee,  GA  30024 
Contact:  Dr.  William  E.  Longo 
Phone:  770-448-3200 
Fax:  770-368-8256 
E-Mail:  blongo@mastest.com 
URL:  http://www.mastest.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101237-0 

State  of  Connecticut 

Dept.  of  Public  Health  Laboratory 

P.O.  Box  1689 

Hartford,  CT  06144-1689 

Contact:  Ms.  Janet  B.  Kapish 

Phone:  860-509-8538 

Fax:  860-509-8698 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  101247-0 

Micro  Analytical,  Inc. 

11521  W.  North  Ave. 
Milwaukee,  WI  53226 
Contact:  Mr.  Jon  Yakish 
Phone:414-771-0855 
Fax:  414-771-6570 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  December  31,  1999 


NVLAP  1999  DIRECTORY  -  Page  D63 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  101249-0 
Institute  for  Environmental  Assessment 

7101  Northland  Circle 
Brooklyn  Park,  MN  55428-1517 
Contact:  Ms.  Yolanda  Pope 
Phone:  612-535-7721 
Fax:  612-535-9177 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101254-0 

Roy  F.  Weston,  Inc. 

1635  Pumphrey  Avenue 
Auburn,  AL  36832-4303 
Contact:  Mr.  Jamieson  D.  Webb 
Phone:  334-826-6100 
Fax:  334-826-8232 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  101258-0 
DCM  Science  Laboratory,  Inc. 

12421  W.  49th  Ave.,  Unit  6 
Wheat  Ridge,  CO  80033 
Contact:  Ms.  Cindy  Mefford 
Phone:  303-463-8270 
Fax:  303-463-8267 
E-Mail:  dcmscilab@aol.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  101261-0 
Asbestos  Analysis  and  Information  Service,  Inc. 

603  North  Baker  Street 

P.O.  Box  837 

Four  Oaks,  NC  27524 

Contact:  Mr.  Stephen  H.  Westbrook 

Phone:  919-963-2898 

Fax:  919-963-2841 

E-Mail:  STEHWEST@AOL.COM 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  101262-0 
Philip  Analytical  Services 

4418  Pottsville  Pike 
Reading,  PA  19605 
Contact:  Mr.  Fred  Usbeck 
Phone:  610-921-8833 
Fax:  610-921-9667 

E-Mail:  FRED_USBECK@PHILIP-SERV.COM 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  September  30,  1999 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  September  30,  1999 


NVLAP  LAB  CODE  101265-0 

Pace  Analytical 

5156  E.  65th  Street 
Indianapolis,  IN  46220-4871 
Contact:  Mr.  Scott  Patrick  Lindsay 
Phone:  317-845-7730  x1847 
Fax: 317-845-0630 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101269-0 
Volz  Environmental  Services,  Inc. 

1200  Gulf  Lab  Road 
Pittsburgh,  PA  15238-1304 
Contact:  Mr.  George  J.  Skarupa 
Phone:  412-826-8480 
Fax:  412-826-8488 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101270-0 
Pinchin  Environmental  Ltd. 

5749  Coopers  Ave. 
Mississauga  Ontario  L4Z  1R9 
CANADA 

Contact:  Ms.  Wendy  Bunner 
Phone:  905-507-4850 
Fax:  905-507-4884 
E-Mail:  kslayer@pinchin.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  September  30,  1999 


NVLAP  1999  DIRECTORY  -  Page  D64 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  101277-0 
EMSL  Analytical,  Inc. 

Prosperity  Plaza 

3020  Hamaker  Court,  Suite  B-l  1 0 

Fairfax,  VA  22301 

Contact:  Mr.  Ronald  Mahoney 

Phone:  703-208-3200 

Fax:  703-208-1822 

E-Mail:  mwatson@mantech.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101282-0 
Mystic  Air  Quality  Consultants,  Inc. 

1204  North  Road 

Groton,  CT  06340 

Contact:  Mr.  Christopher  J.  Eident 

Phone:  203-449-8903 

Fax:  203-449-8860 

E-Mail:  MAQC2@AOL.COM 

URL:  http://www.mysticair.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  September  30,  1999 


NVLAP  LAB  CODE  101288-0 
University  (State)  Hygienic  Laboratory 

University  of  Iowa 

102  Oakdale  Campus,  #H101  OH 

Iowa  City,  IA  52242-5002 

Contact:  Dr.  George  Breuer 

Phone:  319-335-4500 

Fax: 319-335-4555 

E-Mail:  gbreuer@uhl.uiowa.edu 

URL:  http://www.uhl.uiowa.edu 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101292-0 
Maxim  Technologies,  Inc. 

600  South  25th  Street 

P.O.  Box  30615 

Billings,  MT  59107 

Contact:  Ms.  Kathleen  A.  Smit 

Phone:  406-248-9161 

Fax:  406-248-9282 

E-Mail:  maximT@wtp.net 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,1 999 


NVLAP  LAB  CODE  101295-0 

ERT  Testing  Services 

211  Glendale,  Suite  425 
Highland  Park,  MI  48203 
Contact:  Ms.  Rose  Grier 
Phone:  313-865-0600 
Fax: 313-865-8951 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  101301-0 

PMK  Group,  Inc. 

629  Springfield  Road 

Kenilworth,  NJ  07033 

Contact:  Mr.  James  Ferris 

Phone:  908-686-0044 

Fax:  908-686-0715 

E-Mail:  jimf@mars.superlink.net 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  101306-0 
Environmental  Services  International,  Inc. 

6404  MacCorkle  Avenue,  SW,  Suite  #2 
St.  Albans,  WV  25177 
Contact:  Mr.  Scott  Rodeheaver 
Phone: 304-768-2233 
Fax:  304-768-9988 
E-Mail:  esilab@citynet.net 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  September  30,  1999 


NVLAP  LAB  CODE  101323-0 
PA  DEP  Bureau  of  Laboratories 

P.O.  Box  1467 
Harrisburg,  PA  17105-1467 
Contact:  Mr.  Floyd  D.  Kefford 
Phone:  717-787-4669 
Fax:  717-783-1502 

E-Mail:  Kefford.Floyd@al.DEP.state.PA.US 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  1999  DIRECTORY  -  Page  D65 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  101331-0 

Kellco  Services,  Inc. 

3137  Diablo  Ave. 

Hayward,  CA  94545 

Contact:  Dr.  Xiaomin  (Simon)  Wang 

Phone:  510-786-9751 

Fax:  510-786-9625 

E-Mail:  xwang@kellco.com 

URL:  http://www.kellco.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 

NVLAP  LAB  CODE  101332-0 
New  York  Testing  Laboratories,  Inc. 

100  Sweeneydale  Avenue 
Bay  Shore,  NY  11706 
Contact:  Mr.  David  Chen 
Phone:  516-491-3800 
Fax:  516-952-7441 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101342-0 

PSI 

4820  West  15th  Street 
Lawrence,  KS  66049-3846 
Contact:  Mr.  Wayne  Dickerson 
Phone:  785-865-9345 
Fax:  785-865-9337 
E-Mail:  wdickers@idir.net 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101343-0 
O'Brien  &  Gere  Laboratories,  Inc. 

5000  Brittonfield  Parkway 
P.O.  Box  4942 
Syracuse,  NY  13221 
Contact:  Mr.  Michael  J.  Gerber 
Phone:  315-437-0200 
Fax:  315-463-7554 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101350-0 

PSI 

850  Poplar  Street 
Pittsburgh,  PA  15220 
Contact:  Mr.  Daniel  Anderson 
Phone:  412-922-4010x260 
Fax:  412-922-4014 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101356-0 
Beling  Consultants,  Inc. 

1001  16th  Street 

Moline,  IL  61265 

Contact:  Mr.  Jeffrey  A.  Wasson 

Phone:  309-757-9814 

Fax:  309-757-9812 

E-Mail:  jwasson@beling.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  101375-0 

Galson  Laboratories 

6601  Kirkville  Road 
P.O.  Box  369 
East  Syracuse,  NY  13057 
Contact:  Ms.  Eva  Galson 
Phone:  315-432-5227 
Fax:  315-437-0571 

URL:  http://www.galsonlabs.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 

NVLAP  LAB  CODE  101383-0 
Lockheed  Martin  Utility  Services,  Inc. 

Portsmouth  Uranium  Enrichment  Plant 
P.O.  Box  628,  3930  US  Route  23 
Piketon,  OH  45661 
Contact:  Ms.  D.  K.  Perez 
Phone:  740-897-5702 
Fax:  740-897-3130 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  1999  DIRECTORY  -  Page  D66 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  101384-0 
Health  Science  Associates 

10771  Noel  Street 

Los  Alamitos,  CA  90720-2547 

Contact:  Ms.  Jaime  Steedman-Lyde 

Phone:  714-220-3922 

Fax:  714-220-2081 

E-Mail:  srosenberg@earthlink.net 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101399-0 
Guardian  Laboratories 

6309  Fern  Valley  Pass 
Louisville,  KY  40228-1059 
Contact:  Dr.  Dan  C.  Visanescu 
Phone:  502-964-0865 
Fax:  502-964-7681 


NVLAP  LAB  CODE  101421-0 
Hillmann  Environmental  Company 

1600  Route  22  East 
Union,  NJ  07083-1597 
Contact:  Ms.  Marianne  Hillmann 
Phone:  908-688-7800 
Fax:  908-686-2636 
E-Mail:  hecopa@penn.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  September  30,  1999 


NVLAP  LAB  CODE  101424-0 
TRC  Environmental  Corporation 

5  Waterside  Crossing 
Windsor,  CT  06095 
Contact:  Mr.  Lance  R.  Cotton 
Phone:  860-298-6326 
Fax:  860-298-6399 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 

NVLAP  LAB  CODE  101410-0 

Davis  &  Floyd,  Inc. 

816  East  Durst  Street 

P.O.  Drawer  428 

Greenwood,  SC  29649 

Contact:  Mr.  E.  Carl  Burrell,  Jr. 

Phone:  864-229-4413 

Fax:  864-229-7119 

E-Mail:  cburrell@davisfloyd.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  101415-0 

Larron  Laboratory 

529  Broadway 

Cape  Girardeau,  MO  63701 

Contact:  Mr.  Ronald  E.  Farrow 

Phone:  573-334-8910 

Fax:  573-334-8910 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  December  31,  1999 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101425-0 
Marine  Chemist  Service,  Inc. 

11 850  Tug  Boat  Lane 
Newport  News,  VA  23606 
Contact:  Ms.  Colleen  Becker 
Phone:  757-873-0933 
Fax:  757-873-1074 

E-Mail:  mchemserv@compuserve.com 
URL:  http://www.marinechemist.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 

NVLAP  LAB  CODE  101433-0 

Dames  &  Moore,  Inc. 

5  Industrial  Way 

Salem,  NH  03079 

Contact:  Mr.  Douglas  R.  Lawson 

Phone:  603-893-0616 

Fax:  603-893-6240 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  1999  DIRECTORY  -  Page  D67 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  101440-0 
RI  Analytical  Laboratories,  Inc. 

41  Illinois  Avenue 
Warwick,  RI  02888-3007 
Contact:  Mr.  Eric  Neff 
Phone:  401-737-8500 
Fax:  401-738-1970 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  101442-0 

ASBESTECH 

6825  Fair  Oaks  Blvd.,  Suite  103 
Carmichael,  CA  95608 
Contact:  Mr.  Tommy  Conlon 
Phone:  916-481-8902 
Fax:  916-481-3975 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101457-0 
Assaigai  Analytical  Laboratories,  Inc. 

7300  Jefferson  NE 
P.O.  Box  90430 
Albuquerque,  NM  87199-0430 
Contact:  Mr.  William  P.  Biava 
Phone:  505-822-8061 
Fax:  505-822-8063 
E-Mail:  bjbiava@swcp.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101459-0 
Forensic  Analytical  Specialties,  Inc. 

3777  Depot  Road,  Suite  409 

Hayward,  CA  94545-2756 

Contact:  Mr.  David  Sandusky 

Phone:  510-887-8828 

Fax:  510-887-4218 

E-Mail:  Daves@forensica.com 

URL:  http://www.forensica.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101459-1 
Forensic  Analytical  Specialties,  Inc. 

2959  Pacific  Commerce  Drive 
Rancho  Domingues,  CA  90221 
Contact:  Matilde  Antillon 
Phone:  310-763-2374 
Fax: 310-763-8684 

URL:  http://www.forensica.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 

NVLAP  LAB  CODE  101463-0 
Northern  Testing  Laboratories,  Inc. 

3330  Industrial  Avenue 

Fairbanks,  AK  99701-7395 

Contact:  Ms.  Cindy  L.  Christian 

Phone:  907-456-31  16 

Fax:  907-456-3125 

E-Mail:  clcntl@polarnet.com 

URL:  http://www2.polarnet.com/~ntl 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 

NVLAP  LAB  CODE  101505-0 
Los  Angeles  Unified  School  District 

BSC  Annex,  Env.  Health  &  Safety  Branch 

1449  So.  San  Pedro  Street 

Los  Angeles,  CA  90015 

Contact:  Mr.  Brett  Koontz 

Phone:  213-743-5086 

Fax:  213-749-8010 

E-Mail:  dbryant@lausd.kl2.ca.us 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  September  30,  1999 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  September  30,  1999 


NVLAP  LAB  CODE  101506-0 
Environmental  Health  Laboratories 

St.  Louis  County  Department  of  Health 
111  So.  Meramec 
Clayton,  MO  63105-171  1 
Contact:  Dr.  Robert  A.  Nicolotti 
Phone:  314-854-6830 
Fax: 314-854-6648 

E-Mail:  robert_nicolotti@co.st-louis.mo.us 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  December  31,  1999 


NVLAP  1999  DIRECTORY  -  Page  D68 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  101510-0 

Fibertec,  Inc. 

2280  Aurelius  Road 

Holt,  MI  48842-2165 

Contact:  Mr.  Phillip  A.  Peterson 

Phone:  517-699-0345 

Fax:  517-699-0388 

E-Mail:  asbestos@fibertec-USA.com 

URL:  http://www.asbestos@fibertec-usa.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  December  3 1 ,  1999 


NVLAP  LAB  CODE  101514-0 
EnviroMed  Services,  Inc. 

25  Science  Park 

New  Haven,  CT  06511 

Contact:  Mr.  Joseph  Pasquariello 

Phone:  203-786-5580 

Fax:  203-786-5579 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101515-0 
Law  Engineering  and  Environmental  Services, 
Inc. 

4919  West  Laurel  Street 
Tampa,  FL  33607 
Contact:  Mr.  Monte  Hall 
Phone:  813-289-0750 
Fax:  813-289-5474 
E-Mail:  mhall@lawco.com 
URL:  http://www.law-USA.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 

NVLAP  LAB  CODE  101515-1 
Law  Engineering  and  Environmental  Services, 
Inc. 

5845  N.W.  158th  Street 
Miami  Lakes,  FL  33014 
Contact:  Chris  DuBour 
Phone:  305-826-5588 
Fax:  305-826-1799 

URL:  http://www.law-USA.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  101523-0 
DHMH-Air  Quality  Laboratory 

201  West  Preston  Street 

P.O.  Box  2355 

Baltimore,  MD  21201-2355 

Contact:  Ms.  Yvonne  Tai-Sen-Choy 

Phone:  410-767-5948 

Fax: 410-333-5403 

URL:  http://www.charm.net/~epi6/labs.htm 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 

NVLAP  LAB  CODE  101530-0 
Department  of  Environmental  Health  Industrial 
Hygiene  Laboratory 

9325  Hazard  Way 
San  Diego,  CA  92123-1217 
Contact:  Mr.  Larry  Marshall 
Phone:  619-694-2232 
Fax:  619-694-3434 

E-Mail:  LMARSHEH@CO.SAN-DIEGO.CA.US 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  December  31,  1999 

NVLAP  LAB  CODE  101539-0 
Puget  Sound  Naval  Shipyard 

Code  134,  Bldg.  371 
1400  Farragut  Ave. 
Bremerton,  WA  98314-5000 
Contact:  Mr.  Michael  Heaton 
Phone:  360-476-8091 
Fax: 360-476-5587 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  101545-0 
Nova  Consulting  Group,  Inc. 

1 107  Hazeltine  Boulevard,  Suite  400 
Chaska,  MN  55318-1008 
Contact:  Mr.  Steve  Cummings 
Phone:  612-448-9393 
Fax:  612-448-9572 
E-Mail:  Novasbc@aol.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  1999  DIRECTORY  -  Page  D69 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  101558-0 
Con  Edison  -  ChemLab 

31-01  20th  Avenue,  Bldg.  138 
Long  Island  City,  NY  11105-2048 
Contact:  Mr.  Edward  Chin 
Phone:  718-204-4148 
Fax:  718-956-8058 


NVLAP  LAB  CODE  101578-0 

AGX,  Inc. 

50  Progress  Avenue 
Cranberry  Township,  PA  16066 
Contact:  Mr.  Daniel  Winkle 
Phone:  724-776-1905 
Fax:  724-776-5714 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  September  30,  1999 


NVLAP  LAB  CODE  101565-0 
Northeast  Test  Consultants 

587  Spring  Street 

P.O.  Box  438 

Westbrook,  ME  04092 

Contact:  Ms.  Laura  Maries 

Phone:  207-854-3939 

Fax:  207-854-3658 

E-Mail:  INFO@NETEST.COM 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101567-0 
South  Coast  Air  Quality  Management  District 

21865  E.  Copley  Drive 

Diamond  Bar,  CA  91765-4182 

Contact:  Ms.  Corazon  B.  Choa 

Phone:  909-396-2172 

Fax:  909-396-2175 

E-Mail:  cchoa@dbar7.aqmd.gov 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  101572-0 
South  Carolina  Department  of  Health  & 
Environmental  Control 

Division  of  Air  Quality  Analysis 
823 1  Parklane  Road 
Columbia,  SC  29223-4903 
Contact:  Mr.  Scott  A.  Reynolds 
Phone:  803-935-7020 
Fax:  803-935-7363 

E-Mail:  reynolds@columb36. dhec.state.se. us 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  101580-0 
Precision  Testing  Laboratories,  Inc. 

1909  S.  Eastern 

Moore,  OK  73160-6060 

Contact:  Mr.  C.  Jack  Harrel 

Phone:  405-793-1468 

Fax:  405-793-1489 

E-Mail:  ptl@mail.iamerica.net 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101587-0 
Environmental  Enterprise  Group(EEG),  Inc. 

1305  East  Main  Street 

Russellville,  AR  72801 

Contact:  Mr.  Keith  Zimmerman 

Phone:  501-968-6767 

Fax: 501-968-1956 

E-Mail:  eeginc@cswnet.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101593-0 
National  Environmental  Reference  Laboratory 

C/O  US  Geological  Survey,  MS  PHL/NERL 

P.O.  Box  25046 

Denver,  CO  80225-0046 

Contact:  Mr.  Bruce  Hills 

Phone:  303-236-3455  x500 

Fax:  303-236-3440 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  1999  DIRECTORY  -  Page  D70 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  101594-0 

TolTest,  Inc. 

1915  North  12th  Street 

P.O.  Box  2186 

Toledo,  OH  43624-1305 

Contact:  Ms.  Susan  Pellitieri 

Phone:419-241-7175 

Fax:419-241-1808 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  101595-0 

Envirotest,  Inc. 

3902  Braxton 

Houston,  TX  77063-6304 

Contact:  Dr.  Stuart  C.  Williams 

Phone:713-782-4411 

Fax:  713-782-3428 

E-Mail:  scw@envirotestinc.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,1 999 


NVLAP  LAB  CODE  101611-0 
Applied  Environmental,  Inc. 

1 1800  Sunrise  Valley  Drive,  Suite  1200 

Reston,  VA  20191 

Contact:  Ms.  Jana  H.  Ambrose 

Phone:  703-648-0822 

Fax:  703-648-0575 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  September  30,  1999 


NVLAP  LAB  CODE  101618-0 

Ambient  Labs,  Inc. 

159  West  25th  Street,  8th  Floor 
New  York,  NY  10001-7203 
Contact:  Mr.  William  Esposito,  Jr. 
Phone:  212-463-7812 
Fax:  212-463-9397 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  September  30,  1999 


NVLAP  LAB  CODE  101631-0 
Pacific  Rim  Environmental,  Inc. 

65 10  Southcenter  Boulevard 

Tukwila,  WA  98188 

Contact:  Mr.  William  F.  Golloway 

Phone:  206-244-8965 

Fax:  206-244-9096 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  101646-0 
Eastern  Analytical  Services,  Inc. 

4  Westchester  Plaza 
Elmsford,NY  10523-1610 
Contact:  Mr.  Paul  Stascavage 
Phone:  914-592-8380 
Fax:  914-592-8956 
E-Mail:  PaulS@EASInc.com 
URL:  http://www.EASInc.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  September  30,  1999 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  September  30,  1999 


NVLAP  LAB  CODE  101649-0 
Asbestos  Consulting  &  Testing  (ACT) 

14953  West  101st  Terrace 
Lenexa,  KS  66215 
Contact:  Mr.  Jim  A.  Pickel 
Phone:  913-492-1337 
Fax:  913-492-1392 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  101656-0 
Precision  Micro-Analysis,  Inc. 

3463  Ramona  Avenue,  Suite  16 
Sacramento,  CA  95826-3827 
Contact:  Mr.  David  G.  Fisher 
Phone:  916-456-4892 
Fax:  916-456-1082 
E-Mail:  dreed@ns.net 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  1999  DIRECTORY  -  Page  D71 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  101661-0 
Aurora  Consolidated  Laboratories 

8901  W.  Lincoln  Avenue 
West  Allis,  WI  53227 
Contact:  Dr.  Leon  Saryan 
Phone:  414-328-7944 
Fax:  414-328-8560 


NVLAP  LAB  CODE  101727-0 

Analyticalab 

8270  Archer  Avenue 

Willow  Springs,  IL  60480 

Contact:  Mr.  Richard  J.  Langenderfer 

Phone:  708-839-1338 

Fax:  708-839-6970 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  101672-0 

TC  Analytics,  Inc. 

1200  Boissevain  Ave. 
Norfolk,  VA  23507 
Contact:  Mr.  Steven  J.E.  Long 
Phone:  757-627-0400 
Fax:  757-627-1118 
E-Mail:  tcgnorfolk@aol.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  December  31,  1999 


NVLAP  LAB  CODE  101703-0 
U.S.  EPA  -  National  Enforcement  Investigations 
Center 

Box  25227  Bldg.  53,  Denver  Federal  Ctr. 
Denver,  CO  80225 
Contact:  Ms.  Peggy  J.  Forney 
Phone:  303-236-5132  x267 
Fax:  303-236-5116 

E-Mail:  forney.peggy@epamail.epa.gov 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  September  30,  1999 


NVLAP  LAB  CODE  101704-0 
Allegheny  Asbestos  Analysis 

416  Anthony  Street 
Carnegie,  PA  15106 
Contact:  Ms.  Tammy  Seiler 
Phone:  412-278-5400 
Fax:  412-278-5404 
E-Mail:  TAMTAZ@SGI.NET 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  101732-0 
United  Analytical  Services,  Inc. 

4413  West  Roosevelt  Road,  Suite  108 
Hillside,  IL  60162-2057 
Contact:  Dr.  Charles  D.  Byers 
Phone:  708-449-0070 
Fax:  708-449-9582 
E-Mail:  kevin4@flash.net 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  101735-0 

Jimmie  Ann  Bolton 

2105  Nathan  Drive 
Austin,  TX  78728-4530 
Contact:  Ms.  Jimmie  Ann  Bolton 
Phone:  512-251-8388 
Fax:  512-459-8396 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101755-0 

PSI 

9  East  37th  Street,  11th  Floor 

New  York,  NY  10016 

Contact:  Mr.  Devaraj  (VJ)  Vijayakumar 

Phone:  212-889-0294 

Fax: 212-889-0493 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  1999  DIRECTORY  -  Page  D72 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  101759-0 
Comprehensive  Health  Services-Environmental 
Health  PLM  Laboratory 

Environmental  Health  PLM  Laboratory 
BOC-022 

Kennedy  Space  Center,  FL  32815 
Contact:  Dr.  Ronald  G.  Cable 
Phone:  407-867-9014 
Fax:  407-867-3694 

E-Mail:  ronald.cable-l@kmail.ksc.nasa.gov 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  September  30,  1999 


NVLAP  LAB  CODE  101768-0 
Carolina  Environmental,  Inc. 

102-H  Commonwealth  Court 
Cary.NC  2751  1 
Contact:  Mr.  John  D.  Koenigs 
Phone:  919-481-1413 
Fax:  919-481-1442 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  101771-0 

Asbestos  Analytical 

25 19  North  Walnut  Avenue 
Tucson,  AZ  85712-2414 
Contact:  Dr.  John  McLean 
Phone:  520-323-7644 
Fax:  520-323-7644 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  September  30,  1999 


NVLAP  LAB  CODE  101775-0 
American  Asbestos  Laboratories,  Inc. 

99  SE  5th  Street,  4th  Floor 

Miami,  FL  33131-2545 

Contact:  Dr.  Daniel  J.  Cottrell 

Phone:  305-374-8300 

Fax:  305-374-9004 

E-Mail:  eegmiami@mindspring.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  101781-0 
Covino  Environmental  Associates,  Inc. 

300  Wildwood  Avenue 
Woburn,  MA  01801 
Contact:  Ms.  Ann  D.  Eckmann 
Phone:  781-933-2555 
Fax:  781-932-9402 
E-Mail:  covino@tiac.net 
URL:  http://www.covino,com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 

NVLAP  LAB  CODE  101793-0 
A  &  B  Environmental  Services,  Inc. 

1 643  Federal  Road 

Houston,  TX  77015 

Contact:  Mr.  Robert  L.  Voorhies 

Phone:  713-453-6060 

Fax:  713-453-6091 

E-Mail:  aandblab@flash.net 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  December  31,  1999 


NVLAP  LAB  CODE  101803-0 

CAMCO  Lab 

1 1 040  Rose  Avenue 
Fontana,  CA  92337-7051 
Contact:  Ms.  Pamela  Landreth 
Phone:  909-428-3099 
Fax:  909-428-3098 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101807-0 
EnvironMETeo  Services  Inc. 

94-5 1 5  Ukee  Street,  Suite  304 
Waipahu,  HI  96797 
Contact:  Mr.  Clifford  How 
Phone:  808-671-8383 
Fax:  808-671-7979 
E-Mail:  emet@aloha.net 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  1999  DIRECTORY  -  Page  D73 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  101832-0 
A.R.C.  Laboratories,  Inc. 

1323  9th  Avenue  South 
Grand  Forks,  ND  58201 
Contact:  Mr.  Joseph  J.  Worman 
Phone:  701-772-6496 
Fax:  701-772-6416 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101847-0 
Law  Engineering  and  Environmental  Services, 
Inc. 

22455  Davis  Drive,  Suite  100 
Sterling,  VA  20164 
Contact:  Mr.  Ronald  M.  Combs 
Phone:  703-404-7000 
Fax:  703-404-7070 


NVLAP  LAB  CODE  101855-0 
Analytical  Industries,  Inc. 

6025  Kentucky  Dam  Road 
P.O.  Box  3327 
Paducah,  KY  42003 
Contact:  Mr.  Steve  Stamper 
Phone:  502-898-8683 
Fax:  502-898-3531 
E-Mail:  aii@apex.net 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  101864-0 
Design  for  Health,  Inc. 

3475  Kettner  Blvd. 
San  Diego,  CA  92101 
Contact:  Mr.  Kabir  Shefa 
Phone:  619-291-1777 
Fax:  619-291-4318 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  December  31,  1999 


NVLAP  LAB  CODE  101848-0 
Environmental  Testing,  Inc. 

100  South  Cass  Street 
P.O.  Box  138 

Middletown,  DE  19709-0138 

Contact:  Ms.  Lee  Ann  Shinaberry 

Phone:  302-378-4955 

Fax:  302-378-9107 

E-Mail:  MAC.ECSI@DEL.NET 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  September  30,  1999 


NVLAP  LAB  CODE  101853-0 
RCM  Laboratories,  Inc. 

5400  East  Avenue,  Second  Floor 
Countryside,  IL  60525 
Contact:  Dr.  Tianbao  Bai 
Phone:  708-485-8600 
Fax:  708-485-8607 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  December  31,  1999 

NVLAP  LAB  CODE  101868-0 

AIResearch,  Inc. 

Environmental  Consultants  and  Laboratory 

2969  N.  114th  Street 

Wauwatosa,  WI  53222 

Contact:  Ms.  Jill  Frey 

Phone:  414-476-3131 

Fax:  414-476-2201 

E-Mail:  airesrch@execpc.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  September  30,  1999 


NVLAP  LAB  CODE  101869-0 
Northwest  Envirocon,  Inc. 

101  East  8th  Street,  Suite  250 
Vancouver,  WA  98660 
Contact:  Mr.  Naresh  C.  Singh,  CQA 
Phone:  360-699-4015 
Fax:  360-699-5223 

E-Mail:  nareshsingh@nwenvirocon.com 
URL:  http://www.nwenvirocon.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  December  31,  1999 


NVLAP  1999  DIRECTORY  -  Page  D74 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  101870-0 
Sun  City  Analytical,  Inc. 

1409  Montana 
El  Paso,  TX  79902 
Contact:  Ms.  Priscilla  Acuna 
Phone:  915-533-8840 
Fax:  915-533-8843 
E-Mail:  scai@flash.net 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  September  30,  1999 


NVLAP  LAB  CODE  101871-0 
Apollo  Environmental,  Inc. 

1 1553  U.S.  Highway  41  South 
P.O.  Box  239 

Gibsonton,  FL  33534-9720 
Contact:  Mr.  Michael  L.  Williamson 
Phone:  813-671-3999 
Fax:  813-677-3422 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  September  30,  1999 


NVLAP  LAB  CODE  101872-0 
Micro  Analytical  Laboratories,  Inc. 

5900  Hollis  Street,  Suite  M 

Emeryville,  CA  94608-2008 

Contact:  Mr.  Frank  Raviola 

Phone:  510-653-0824 

Fax: 510-653-1361 

E-Mail:  microlab@labmicro.com 

URL:  http://www.labmicro.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  September  30,  1999 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  September  30,  1999 


NVLAP  LAB  CODE  101882-0 
Environmental  Hazards  Services,  L.L.C. 

7469  White  Pine  Road 

Richmond,  VA  23237 

Contact:  Ms.  Irma  Faszewski 

Phone:  804-275-4788 

Fax:  804-275-4907 

E-Mail:  managerqaqc@leadlab.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  December  31,1 999 


NVLAP  LAB  CODE  101884-0 
Concord  Analysis,  Inc. 

9960  Canoga  Ave.,  Suite  D8 
Chatsworth,  CA  91311-6704 
Contact:  Ms.  Johanna  Fann 
Phone:  818-407-0128 
Fax:  818-882-9409 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  101886-0 
Prezant  Associates,  Inc. 

330  Sixth  Avenue  North,  Suite  200 

Seattle,  WA  98109 

Contact:  Mr.  George  G.  McCaslin 

Phone:  206-281-8858  xl35 

Fax:  206-281-8922 

E-Mail:  jmccaslin@prezant.com 

URL:  http://www.prezant.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  December  31,  1999 

NVLAP  LAB  CODE  101890-0 
Mountain  Laboratories 

10905  East  Montgomery  Avenue,  Suite  2 
Spokane,  WA  99206 
Contact:  Mr.  Wade  K.  Johnston 
Phone:  406-728-7755 
Fax:  406-728-7367 
E-Mail:  mcswade@ism.net 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  September  30,  1999 


NVLAP  LAB  CODE  101891-0 
Asbestos  TEM  Laboratories,  Inc. 

1409  Fifth  Street,  Suite  C 

Berkeley,  CA  94710 

Contact:  Mr.  R.  Mark  Bailey 

Phone:  510-528-0108 

Fax:  510-528-0109 

E-Mail:  MBaileyASB@aol.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  1999  DIRECTORY  -  Page  D75 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  101894-0 
Midwest  Laboratories,  Inc. 

6246  Joliet  Road,  Suite  4 
Countryside,  IL  60525 
Contact:  Mr.  James  P.  Hahn 
Phone:  708-354-71  17 
Fax:  708-354-7142 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  September  30,  1999 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  September  30,  1999 


NVLAP  LAB  CODE  101895-0 
McCall  and  Spero  Environmental,  Inc. 

13005  Middletown  Industrial  Blvd. 
Suite  H 

Louisville,  KY  40223 
Contact:  Mr.  R.  Dale  McCall 
Phone:  502-244-7135 
Fax:  502-244-7136 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101896-0 
Reservoirs  Environmental  Services,  Inc. 

1827  Grant  Street 

Denver,  CO  80203 

Contact:  Ms.  Jeanne  Spencer  Orr 

Phone:  303-830-1986 

Fax:  303-863-9196 

E-Mail:  residen@rmi.net 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101896-1 
Reservoirs  Environmental  Services,  Inc. 

1 147  Brittmore  Road,  Suite  1 12 
Houston,  TX  77043 
Contact:  Brett  S.  Colbert 
Phone:  713-932-0015 
Fax:  713-984-0963 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101902-0 

E.  M.  Analytical,  Inc. 

8000  North  Ocean  Drive 
Dania,  FL  33004-3078 
Contact:  Ms.  Pat  Blackwelder 
Phone:  305-751-1184 
Fax:  954-921-6747 

E-Mail:  pblackwelder@rsmas.miami.edu 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101904-0 
Scientific  Laboratories,  Inc. 

13635  Genito  Road 

Midlothian,  VA  23112 

Contact:  Mr.  Scot  Cooke 

Phone:  804-763-1200 

Fax:  804-379-1087 

E-Mail:  SCILAB5@EROLS.COM 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101904-1 
Scientific  Laboratories,  Inc. 

117  East  30th  Street 

New  York,  NY  10016 

Contact:  Dr.  Robert  E.  Tompkins 

Phone:  212-679-8600 

Fax:  212-679-9392 

E-Mail:  SCILAB7@EROLS.COM 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101909-0 
Analytical  Labs  San  Francisco,  Inc. 

470  Potrero  Avenue 
San  Francisco,  CA  94110 
Contact:  Ms.  Olga  Kist 
Phone:  415-552-4595 
Fax:  415-552-0730 
E-Mail:  alsf@wnet.net 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  1999  DIRECTORY  -  Page  D76 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  101910-0 
PBS  Environmental  Building  Consultants,  Inc. 

1220  SW  Morrison  Street,  Suite  600 
Portland,  OR  97205-2225 
Contact:  Mr.  Rollie  Champe 
Phone:  503-248-1939 
Fax: 503-248-0223 

URL:  http://www.pbsenv.com/pbsinfo 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 

NVLAP  LAB  CODE  101917-0 
DataChem  Laboratories 

4388  Glendale-Milford  Road 

Cincinnati,  OH  45242-3706 

Contact:  Ms.  Anna  Marie  Ristich 

Phone:  513-733-5336 

Fax: 513-733-5347 

E-Mail:  JCARTER702@AOL.COM 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  September  30,  1999 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  September  30,  1999 


NVLAP  LAB  CODE  101920-0 

Lab/Cor,  Inc. 

7619  6th  Avenue,  NW 
Seattle,  WA  98117-4037 
Contact:  Mr.  John  Harris 
Phone:  206-781-0155 
Fax:  206-789-8424 
E-Mail:  labcorl@aol.com 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  September  30,  1999 


NVLAP  LAB  CODE  101926-0 
Environmental  Management  Consultants,  Inc. 

7342  East  Thomas  Road 
Scottsdale,  AZ  85251-7216 
Contact:  Mr.  Kurt  A.  Kettler 
Phone:  602-840-8012 
Fax:  602-990-8468 
E-Mail:  kkettler@earthlink.net 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101937-0 
Environmental  Testing  Laboratories,  Inc. 

208  Route  109 
Farmingdale,  NY  11735 
Contact:  Mr.  Daniel  J.  Spandau 
Phone:  516-249-1456 
Fax: 516-249-8344 


Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101941-0 

Kevco  Services,  Inc. 

890  Pittsburgh  Road 
Butler,  PA  16002-8901 
Contact:  Mr.  George  M.  Beck 
Phone:  724-586-6343 
Fax:  724-586-2172 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101948-0 

MACS  Lab,  Inc. 

2070A  Walsh  Avenue 

Santa  Clara,  CA  95050-2531 

Contact:  Mr.  James  A.  Richards 

Phone:  408-727-9727 

Fax:  408-727-7065 

E-Mail:  jrichards@macslab.com 

URL:  http://www.macslab.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  March  31,1 999 


NVLAP  LAB  CODE  101950-0 
WKP  Laboratories,  Inc. 

46  South  Highland  Avenue 
Ossining,  NY  10562 
Contact:  Mr.  Fabio  J.  Pedone 
Phone:  914-941-1023 
Fax:  914-941-7359 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  September  30,  1999 


NVLAP  1999  DIRECTORY  -  Page  D77 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  101953-0 
JLC  Environmental  Consultants,  Inc. 

200  Park  Avenue  South,  Suite  1001 
New  York,  NY  10003 
Contact:  Mr.  Al  Wallner 
Phone:  212-420-8119 
Fax:  212-420-6092 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  September  30,  1999 


NVLAP  LAB  CODE  101958-0 
Athenica  Environmental  Services,  Inc. 

45-09  Greenpoint  Avenue 
Long  Island  City,  NY  11104 
Contact:  Mr.  Spiro  Dongaris 
Phone:  718-784-7490 
Fax:  718-784-4085 


NVLAP  LAB  CODE  101967-0 
NY  Environmental  &  Analytical  Labs,  Inc. 

88  Harbor  Road 
Port  Washington,  NY  11050 
Contact:  Mr.  Li  Tsang 
Phone:  516-944-9500 
Fax:  516-944-9507 
E-Mail:  ltsang@idt.net 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101970-0 

PSI 

500  West  Central  Avenue,  Suite  A 

Brea,  CA  92821 

Contact:  Ms.  Lauren  Johnstone 

Phone:  714-671-1072 

Fax:  714-529-7229 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  September  30,  1999 


NVLAP  LAB  CODE  101959-0 
QuanTEM  Laboratories,  LLC 

2033  Heritage  Park  Drive 
Oklahoma  City,  OK  73 1 20-7579 
Contact:  Mr.  John  E.  Barnett 
Phone:  405-755-7272 
Fax:  405-755-2058 
E-Mail:  quantem  ionet.net 
URL:  http://www.quantem.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  September  30,  1999 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  September  30,  1999 


NVLAP  LAB  CODE  101965-0 
Bell  Laboratories,  Division  Lucent  Technologies, 
Inc. 

P.O.  Box  636,  600  Mountain  Avenue 
Murray  Hill,  NJ  07974-0636 
Contact:  Ms.  Lisa  Brooks 
Phone:  908-582-7157 
Fax:  908-582-7233 
E-Mail:  LB@lucent.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  December  31,  1999 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101973-0 
Law  Engineering  and  Environmental  Services, 
Inc. 

7616  LBJ  Freeway,  Suite  600 
Dallas,  TX  75251 
Contact:  Mr.  John  R.  Cates 
Phone:  972-934-0800 
Fax:  972-934-1429 
E-Mail:  jcates@lawco.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101974-0 
Rapid  Environmental  Management,  Inc. 

171  Great  Neck  Road 
Great  Neck,  NY  11021 
Contact:  Mr.  Joseph  Sterinbach 
Phone:  516-482-3003 
Fax:  516-482-3076 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  1999  DIRECTORY  -  Page  D78 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  101977-0 
ACM  Environmental,  Inc. 

229  South  Michigan  Street 
South  Bend,  IN  46601 
Contact:  Mr.  Michael  A.  Dials 
Phone:  219-234-8435 
Fax:  219-234-6800 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101990-0 
Iowa  Environmental  Services,  Inc. 

4801  Grand  Avenue 
Des  Moines,  IA  50312 
Contact:  Mr.  Richard  E.  Soyer 
Phone:  515-279-8042 
Fax:515-279-1853 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  101996-0 
GA  Environmental  Services,  Inc. 

401  Baldwin  Tower 
1510  Chester  Pike 
Eddystone,  PA  19022 
Contact:  Ms.  Delores  S.  Beard 
Phone:  610-874-7405 
Fax:  610-874-7823 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  101997-0 

Hygieneering,  Inc. 

7575  Plaza  Court 

Willowbrook,  IL  60521 

Contact:  Ms.  Jacqueline  M.  Cadwallader 

Phone:  630-654-2550 

Fax:  630-789-3813 

URL:  http://www.hygieneering.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  September  30,  1999 


NVLAP  LAB  CODE  102000-0 
Louisiana  Department  of  Environmental  Quality 
Microanalytical  Lab 

Microanalytical  Lab 

8000  GSRI  Avenue,  Building  #402 

Baton  Rouge,  LA  70820 

Contact:  Ms.  Pamela  D.  Ellis 

Phone:  504-765-0876 

Fax:  504-765-0048 

E-Mail:  pame@deq.state.la.us/ 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  102001-0 
Testing  Mechanics  Corp. 

3770  Merrick  Road 
Seaford,  NY  1  1783-2815 
Contact:  Mr.  Kevin  Tumulty 
Phone:  516-221-3800 
Fax:  516-221-3810 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  102003-0 

GLE  Associates,  Inc. 

1451  Channelside  Drive,  Suite  200 
Tampa,  FL  33605 
Contact:  Mr.  James  Watson 
Phone:  813-241-8350 
Fax:  813-241-8737 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  102005-0 
University  of  Alabama  Asbestos  Laboratory 

Bryant  Drive  -  Martha  Parham  West 
P.O.  Box  870388 
Tuscaloosa,  AL  35487-0388 
Contact:  Ms.  Lynn  M.  Fondren 
Phone:  205-348-8571 
Fax:  205-348-9286 

E-Mail:  LFONDREN@CCS.UA.EDU 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  December  31,  1999 


NVLAP  1999  DIRECTORY  -  Page  D79 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  102006-0 
Solar  Environmental  Services,  Inc. 

1 131  E.  76th  Avenue,  Suite  102 
Anchorage,  AK  99518 
Contact:  Ms.  Gracita  O.  Torrijos 
Phone:  907-349-7705 
Fax:  907-349-7944 
E-Mail:  sesenvir@ak.net 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  102008-0 
Micro  Air  of  Texas,  Inc. 

1052  Hercules  Drive 
Houston,  TX  77058 
Contact:  Mr.  Eric  Eitzen 
Phone:  281-280-9965 
Fax:  281-280-9847 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  102010-0 
Fluor  Daniel  Fernald,  Inc.,  Analytical  Laboratory 
Services 

P.O.  Box  538704 
Cincinnati,  OH  45253-8704 
Contact:  Ms.  Amy  Meyer 
Phone:  513-648-5423 
Fax:  513-648-5198 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  10201 1-0 
Airtek  Environmental  Corp. 

39  West  38th  Street,  12th  Floor 
New  York,  NY  10018 
Contact:  Mr.  Saad  Zouak 
Phone:  212-768-0516 
Fax:  212-768-0759 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  102012-0 
JMS  Environmental  Associates,  Ltd. 

816  Burr  Oak  Drive 
Westmont,  IL  60559 
Contact:  Mr.  John  Aschbacher 
Phone:  630-655-8500 
Fax:  630-655-8724 
E-Mail:  jms@starnetinc.com 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  March  31,  1999 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  102013-0 
Hi-Tech  Environmental  and  Laboratory  Services 

DBA  Hi-Tech  Environmental  &  Lab.  Srvs. 

5396  Lincoln  Ave.,  Suite  A 

Cypress,  CA  90630 

Contact:  Ms.  Gwenda  Hatcher 

Phone:  714-827-0693 

Fax:  714-827-0695 

E-Mail:  Hitechol@ix.netcom.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  December  31,  1999 


NVLAP  LAB  CODE  102015-0 
ABM  Environmental  Consultants,  Inc. 

32-08  38th  Ave.,  Suite  203 
Long  Island  City,  NY  11101 
Contact:  Mr.  Victor  Khanin 
Phone:  718-472-0558 
Fax:  718-472-0548 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 

NVLAP  LAB  CODE  102020-0 
Los  Angeles  Harbor  Department  Testing 
Laboratory 

P.O.  Box  786,  514  Pier  A  Street 
Wilmington,  CA  90744-6499 
Contact:  Mr.  George  Horeczko 
Phone:  310-732-3976 
Fax:  310-835-5717 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  September  30,  1999 


NVLAP  1999  DIRECTORY  -  Page  D80 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  102021-0 
Safe  Environment  of  America 

dba  Med-Tox  Northwest 

19032  66th  Avenue  S.,  #C-105 

Kent,  WA  98032 

Contact:  Mr.  Scott  Harper 

Phone:  425-656-2920 

Fax:  425-656-2924 

E-Mail:  medtownw@msn.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  102025-0 

OCCU-TEC,  Inc. 

6700  Corporate  Drive,  Suite  130 

Kansas  City,  MO  64120 

Contact:  Mr.  Geoffrey  Smith 

Phone:  816-231-5580 

Fax:816-231-5641 

E-Mail:  occutec@unicom.net 

URL:  http://www.occutec.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 

NVLAP  LAB  CODE  102029-0 

ESG  Laboratories 

5933  W.  71st  Street 
Indianapolis,  IN  46278 
Contact:  Ms.  Mary  Dunlap 
Phone:  317-290-1471 
Fax:  317-290-1670 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  December  31,  1999 


NVLAP  LAB  CODE  102031-0 
ATC  Environmental,  Inc. 

6746  South  Revere  Parkway,  Suite  1 80 
Englewood,  CO  80112-6708 
Contact:  Mr.  Jeffrey  Lomme 
Phone:  303-799-6100 
Fax:  301-799-3441 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  102033-0 
Analytical  Environmental  Services,  Inc. 

3781  Presidential  Parkway,  Suite  1 1 1 

Atlanta,  GA  30340 

Contact:  Mr.  Mehmet  Yildirim 

Phone:  770-457-8177 

Fax:  770-457-8188 

E-Mail:  EPHESUS@worldnet.att.net 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  September  30,  1999 


NVLAP  LAB  CODE  102035-0 
Law  Engineering  and  Environmental  Services, 
Inc. 

4634  S.  36th  Place 
Phoenix,  AZ  85040 
Contact:  Mr.  Michael  A.  Cook 
Phone:  602-437-0250 
Fax:  602-437-3675 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  102041-0 
R.  Robinson  Analytical  Services,  Inc. 

1960  Peyton  Drive 

Pensacola,  FL  32503 

Contact:  Mr.  William  F.  Robin  Robinson 

Phone:  850-438-5552 

Fax:  850-432-7394 

E-Mail:  rrobinson@gulf.net 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  102043-0 
Water,  Earth  Solutions  &  Technologies,  Inc. 

17130  Dallas  Parkway,  Suite  120 
Dallas,  TX  75248-1  139 
Contact:  Mr.  Karl  Schul 
Phone: 972-380-9444 
Fax:  972-380-9449 

URL:  http://www.water-earth.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  1999  DIRECTORY  -  Page  D81 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  102044-0 
Loflin  Environmental  Services 

2020  Montrose,  Suite  100 
Houston,  TX  77006 
Contact:  Mr.  James  Murray 
Phone:  713-521-3300 
Fax:  713-523-0829 


NVLAP  LAB  CODE  102053-0 
Dove  Environmental  Corporation 

4715  NW  157th  Street,  Suite  203 

Miami,  FL  33014 

Contact:  Mr.  Rajendranath  Ramnath 

Phone:  305-620-6050 

Fax:  305-620-6350 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  102046-0 
Criterion  Laboratories,  Inc. 

3370  Progress  Drive,  Suite  J 

Bensalem,  PA  19020 

Contact:  Ms.  Parvaneh  S.  Sulon 

Phone:  215-244-1300 

Fax:  215-244-4349 

E-Mail:  CritenonL@aol.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  102047-0 

KAM  Consultants 

5-17  48th  Avenue 

Long  Island  City,  NY  11101 

Contact:  Mr.  George  Kouvaras 

Phone:  718-729-1997 

Fax:  718-729-1876 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  June  30,  1999 

NVLAP  LAB  CODE  102050-0 
Occupational  Health  Conservation,  Inc. 

1840  Southside  Blvd.,  Suite  3C 
Jacksonville,  FL  32216-0317 
Contact:  Ms.  A.  Lynn  Bundoc 
Phone:  904-725-8279 
Fax:  904-721-2809 
E-Mail:  lab@ohcnet.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  102056-0 
Steve  Moody  Micro  Services,  Inc. 

1510  Randolph  St.,  Suite  #602 

Carrollton,  TX  75006 

Contact:  Mr.  Steve  Moody 

Phone:  972-446-9482 

Fax:  972-446-9870 

E-Mail:  SMMS1@AIRMAIL.NET 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  June  30,  1999 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  102057-0 

Niche  Analysis,  Inc. 

6  Gramatan  Avenue,  Suite  404 
Mount  Vernon,  NY  10550 
Contact:  Dr.  Thomas  Palackal 
Phone:  914-663-8937 
Fax:  914-663-8782 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  102060-0 
Froehling  &  Robertson,  Inc. 

3015  Dumbarton  Road 

P.O.  Box  27524 

Richmond,  VA  23261-7524 

Contact:  Mr.  Jeffrey  M.  Hudson 

Phone:  804-264-2701 

Fax:  804-266-1275 

E-Mail:  AOL@FRCHemical 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  1999  DIRECTORY  -  Page  D82 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  102061-0 
Omni  Environmental,  Inc. 

13740  Research  Blvd.,  Suite  H-5 

Austin,  TX  78750 

Contact:  Mr.  Joseph  Mink 

Phone: 512-258-9114 

Fax:  512-258-9115 

E-Mail:  jmink@prismnet.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  102062-0 
National  Econ  Corporation 

730  El  Camino  Real 

Tustin,  CA  92780 

Contact:  Mr.  Mark  S.  Ervin 

Phone:  714-730-9235 

Fax:  714-730-9236 

E-Mail:  http://nationaleconcorp.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  December  31,  1999 


NVLAP  LAB  CODE  102063-0 
NVL  Laboratories,  Inc. 

4708  Aurora  Avenue  N. 
Seattle,  WA  98103 
Contact:  Mr.  Nghiep  Vi  Ly 
Phone:  206-547-0100 
Fax:  206-634-1936 
E-Mail:  munaf@nvllabs.com 
URL:  http://www.nvllabs.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  September  30,  1999 

NVLAP  LAB  CODE  102064-0 
GPU  Nuclear  Chemistry/Materials  Labs. 

Route  1 83  &  Van  Reed  Road 
P.O.  Box  15152 
Reading,  PA  19612-5152 
Contact:  Mr.  Barry  Llewellyn 
Phone:  610-375-5494 
Fax:  610-375-5820 

E-Mail:  BLLEWELLYN@GPU.COM 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  September  30,  1999 


NVLAP  LAB  CODE  102065-0 
Wonder  Makers  Environmental,  Inc. 

2117  Lane  Boulevard 

P.O.  Box  50209 

Kalamazoo,  MI  49005-0209 

Contact:  Dr.  Michael  Pinto 

Phone:  616-382-4154 

Fax:  616-382-4161 

E-Mail:  info@wondermakers.com 

URL:  http://www.wondermakers.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  September  30,  1999 

NVLAP  LAB  CODE  102071-0 

ATC  Associates  Inc. 

11121  Canal  Road 

Cincinnati,  OH  45241 

Contact:  Mr.  Karl  D.  Feldmann 

Phone:  513-771-21 12 

Fax:  513-782-6920 

E-Mail:  feldman72@atc-enviro.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  December  31,  1999 


NVLAP  LAB  CODE  102073-0 
Triad  Environmental  Consulting,  Inc. 

309  3rd  Avenue 
Huntington,  WV  25701 
Contact:  Mr.  Brian  E.  Galligan 
Phone:  304-523-2195 
Fax:  304-523-2197 
E-Mail:  Duxster@earthlink.net 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  102075-0 

S&ME,  Inc. 

9751  Southern  Pine  Boulevard 

P.O.  Box  7668 

Charlotte,  NC  28241-7668 

Contact:  Mr.  Charles  J.  Brockman 

Phone:  704-523-4726 

Fax:  704-525-3953 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  December  31,  1999 


NVLAP  1999  DIRECTORY  -  Page  D83 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  102077-0 
Henderson/Longfellow  Associates,  Inc. 

33  Fourth  St.  North 

St.  Petersburg,  FL  33701 

Contact:  Mr.  John  J.  Henderson 

Phone:  727-550-0603 

Fax:  727-550-9315 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  December  31,  1999 


NVLAP  LAB  CODE  102078-0 

FRS  Geotech,  Inc. 

1441  West  46th  Avenue,  Suite  14 

Denver,  CO  8021  1-2338 

Contact:  Mr.  Ed  Raines 

Phone:  303-477-2559 

Fax:  303-477-2580 

E-Mail:  frsgeo@ix.netcom.com 

URL:  http://www.netcome.com/frsgeo/ 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  December  31,  1999 

NVLAP  LAB  CODE  102079-0 
SCILAB  BOSTON,  Inc. 

8  School  Street 
East  Weymouth,  MA  02 1 89 
Contact:  Mr.  John  Sulkowski 
Phone:  781-337-9334 
Fax:  781-337-7642 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  102080-0 
National  Analytical  Laboratories,  Inc. 

503  Giuseppe  Court  #8 
Roseville,  CA  95678 
Contact:  Mr.  Ron  Weyand 
Phone:  916-786-7555 
Fax:  916-786-7459 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  102081-0 
Legend  Technical  Services,  Inc. 

775  Vandalia  Street 
St.  Paul,  MN  55114 
Contact:  Ms.  Cheryl  Sykora 
Phone:  612-642-1150 
Fax:  612-642-1239 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  102082-0 
Geo- Analytical  Services,  Inc. 

3125  Marjan  Drive 

Atlanta,  GA  30340 

Contact:  Dr.  A.  Mohamad  Ghazi 

Phone:  770-454-6333 

Fax:  770-451-3151 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  September  30,  1999 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  September  30,  1999 


NVLAP  LAB  CODE  102085-0 
Muranaka  Environmental  Consultants,  Inc. 

500  Alakawa  Street,  Suite  220 

P.O.  Box  4341 

Honolulu,  HI  96812 

Contact:  Mr.  Mark  T.  Muranaka 

Phone:  808-848-8866 

Fax:  808-847-5267 

E-Mail:  MMURANAKA@AOL.COM 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  December  31,  1999 


NVLAP  LAB  CODE  102086-0 
Dolphin  Environmental  Consultants 

10707  Corporate  Drive,  Suite  102 
Stafford,  TX  77477-4001 
Contact:  Mr.  Joseph  Bury 
Phone:  281-240-4646 
Fax:  281-240-5659 

E-Mail:  JBURY@COMPUSERVE.COM 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  1999  DIRECTORY  -  Page  D84 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  102087-0 
Hygeia  Laboratories,  Inc. 

1300  Williams  Drive,  Suite  A 
Marietta,  GA  30066-6299 
Contact:  Mr.  Clayton  Call 
Phone:  770-514-6933 
Fax:  770-514-6966 


NVLAP  LAB  CODE  102093-0 

EssTek  Ohio,  Inc. 

6950  Engle  Road  #B 

Middleburg  Heights,  OH  44130-3420 

Contact:  Mr.  Clifford  W.  Thomas 

Phone:  440-826-4220 

Fax:  440-826-3841 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  102089-0 
Alpine  Consulting,  Inc. 

1602  South  Murray  Blvd. 
Colorado  Springs,  CO  80916 
Contact:  Mr.  Kevin  R.  Weaver 
Phone:  719-591-2535 
Fax:  719-591-2536 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  102101-0 
Taylor  Environmental  Group,  Inc. 

130  Jericho  Turnpike 
Floral  Park,  NY  11001 
Contact:  Mr.  George  Taylor 
Phone:  516-358-2955 
Fax: 516-358-1780 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  102090-0 
Bay  Area  Air  Quality  Management  District 

939  Ellis  Street 
San  Francisco,  CA  94109 
Contact:  Ms.  Cleofina  David 
Phone:  415-749-4629 
Fax:  415-749-5101 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  102091-0 
Converse  Consultants  MR,  Inc. 

4840  Mill  Street  #5 
Reno.NV  89502 
Contact:  Mr.  Dan  R.  Dolk 
Phone:  702-856-3833 
Fax:  702-856-3513 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  December  31,  1999 


NVLAP  LAB  CODE  102102-0 
American  Electric  Power,  Environmental 
Laboratory 

Environmental  Laboratory 
1  Riverside  Plaza 
Columbus,  OH  43215-2373 
Contact:  Mr.  Geoffrey  E.  Campbell 
Phone:  614-836-4210 
Fax:  614-836-4168 

E-Mail:  Geoffrey_E._Campbell@AEP.COM 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  102104-0 
EMSL  Analytical,  Inc. 

620-G  Guilford  College  Road 
Greensboro,  NC  27409 
Contact:  Mr.  Matthew  Thomas 
Phone:  336-297-1487 
Fax:  336-297-1676 

URL:  http://www.emsl.com/ 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  1999  DIRECTORY  -  Page  D85 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  102105-0 
EMSL  Analytical,  Inc. 

20  Altieri  Way  #4 
Warwick,  RI  02886 
Contact:  Mr.  Donald  Pellegrino 
Phone:  401-738-7710 
Fax:  401-738-7869 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  102106-0 
EMSL  Analytical,  Inc. 

2501  Central  Parkway,  Suite  C-13 
Houston,  TX  77092 
Contact:  Mr.  Lee  W.  Poye 
Phone:  713-686-3635 
Fax:  713-686-3645 

URL:  http://www/emsl.com/ 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  102108-0 
m.a.c.  Paran  Consulting  Services,  Inc. 

Analytical  Laboratory 

325  West  Ohio  Pike,  Suite  202 

Amelia,  OH  45102 

Contact:  Mr.  Daniel  T.  Woody 

Phone:  513-752-9111 

Fax:  513-752-7973 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  September  30,  1999 


NVLAP  LAB  CODE  102111-0 
Cape  Environmental  Management,  Inc. 

2302  Parklake  Drive,  Suite  200 
Atlanta,  GA  30345-2907 
Contact:  Mr.  Aleksey  Reznik 
Phone:  770-908-7200 
Fax:  770-908-7219 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  102112-0 
Oklahoma  Dept.  of  Environmental  Quality-State 
Environmental  Lab 

1000  NE  10th  Street 
Oklahoma  City,  OK  73117-1212 
Contact:  Mr.  Chris  Armstrong 
Phone:  405-271-5240 
Fax:  405-271-1836 

E-Mail:  CHRIS. Armstrong@degmail.state.ok. us 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  September  30,  1999 


NVLAP  LAB  CODE  102113-0 
MRS.,  Analytical  Laboratory,  Inc. 

233  W.  Broadway,  Suite  #504 
Louisville,  KY  40202 
Contact:  Mr.  Winterford  Mensah 
Phone:  502-568-2088 
Fax:  502-491-7111 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  102114-0 

EAJ,  Inc. 

454  Central  Avenue 
Jersey  City,  NJ  07307 
Contact:  Mr.  Robert  Carvalho 
Phone:  201-714-9858 
Fax:  201-714-9895 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  102115-0 

Industrial  Laboratory 

Norfolk  Naval  Shipyard 
Building  184,  3rd  Fl. 
Portsmouth,  VA  23709-5000 
Contact:  Mr.  Robert  West 
Phone:  757-396-3207 
Fax:  757-396-3972 

E-Mail:  rwest@nnsy_ns00.nnsy.navy.mil 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  1999  DIRECTORY  -  Page  D86 


(See  'How  To  LIse  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  10211 6-0 
Hygeia  Laboratories  Inc. 

82  W.  Sierra  Madre  Blvd. 

Sierra  Madre,  CA  91024-2434 

Contact:  Mr.  Gustavo  Delgado 

Phone:  626-355-4711 

Fax:  626-355-4497 

E-Mail:  gdelgado77@atc-enviro.com 

URL:  htpp://home. earthlink.net/delgadog 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  1021 18-0 
Apex  Research  Laboratory 

8741  Main  Street,  Suite  A 
Whitmore  Lake,  MI  48189 
Contact:  Mr.  Robert  Letarte 
Phone:  734-449-9990 
Fax:  734-449-9991 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  200002-0 
Cryptographic  Equipment  Assessment  Lab. 
(CEAL) 

a  CygnaCom  Solutions  Lab. 

7927  Jones  Branch  Drive,  Suite  100  West 

McLean,  VA  22102-3305 

Contact:  Mr.  Santosh  Chokhani 

Phone:  703-848-0883 

Fax:  703-848-0960 

E-Mail:  chokhani@cygnacom.com 

URL:  http://cygnacom.com 

Cryptographic  Modules  Testing 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

1 7/CO 1       NIST-CSTT:  140-1;  National  Institute  of 
Standards  and  Technology-Cryptographic 
Support  Test  Tool  (CSTT)  for  the  Federal 
Information  Processing  Standard  140-1  (FIPS 
140-1)  "Security  Requirements  for 
Cryptographic  Modules." 

1 7/CO  la     Test  Method  Group  1 :  All  test  methods  derived 
from  FIPS  140-1  and  specified  in  the  CSTT, 
except  those  listed  in  Group  2  and  Group  3. 

1 7/CO  1  b     Test  Method  Group  2:  Test  methods  for 

Physical  Security,  Level  4  derived  from  FIPS 
140-1  and  specified  in  the  CSTT 

1 7/CO  1  c     Test  Method  Group  3 :  Test  methods  for 

Software  Security,  Level  4  derived  from  FIPS 
140-1  and  specified  in  the  CSTT 


NVLAP  LAB  CODE  200004-0 
Integrity  Design  &  Test  Services,  Inc. 

37  Ayer  Road,  Unit  #7 

Littleton,  MA  01460 

Contact:  Mr.  Michael  C.  Boucher 

Phone:  978-486-0432 

Fax:  978-486-3538 

E-Mail:  mboucher@idts.com 

URL:  integrity@idts.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  la      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  1  b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200005-0 
Motorola  Product  Quality  Assurance  Laboratory 

20  Cabot  Boulevard 

Mansfield,  MA  02048 

Contact:  Mr.  James  E.  Powers 

Phone:  508-261-5241 

Fax:  508-339-6738 

E-Mail:  LJP018@email.mot.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO  1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
12/F01b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

1 2/CIS22    IEC/CISPR  22: 1 993 :  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 


NVLAP  1999  DIRECTORY  -  Page  D87 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  200006-0 
NJSP  Calibration  Laboratory 

166  River  Road 
Princeton,  NJ  08540-2939 
Contact:  SGT.  John  Connolly 
Phone:  609-538-6059 
Fax:  609-538-0345 


Ionizing  Radiation  Dosimetry 

Accreditation  Valid  Through:  March  31,  1999 

This  facility  has  been  evaluated  and  deemed  competent  to 
process  the  radiation  dosimeter  listed  below  through 
employing  the  Teledyne  automatic  reader  model  9150. 

This  facility  is  accredited  to  process  the  following 
dosimeter  by  virtue  of  actual  demonstration  of  compliance 
with  ANSI  HPS  N13.1 1-1993  through  testing. 

Teledyne  TLD  model  PB5  for  ANSI-N13. 1 1  categories  II, 
IV. 

NVLAP  LAB  CODE  200007-0 
Lithonia  Testing  Laboratories 

1335  Industrial  Blvd. 
P.O.  Box  A 

Conyers,  GA  30012-9001 
Contact:  Mr.  James  Hospodarsky 
Phone:  770-922-9000  x2424 
Fax:  770-929-8789 


Energy  Efficient  Lighting  Products 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

Luminaires  (Lighting  Fixtures) 
22/F04  IESLM-41 

NVLAP  LAB  CODE  200010-0 
Tri-State  Materials  Testing  Lab,  Inc. 

101 A  Liberty  Street 

Newington,  CT  06111 

Contact:  Mr.  John  P.  Chmielorz 

Phone:  203-666-9954 

Fax:  203-666-0195 

E-Mail:  mattestlab@aol.com 

URL:  http://www.materials-testing.com 

Construction  Materials  Testing 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 
Aggregates 

02/A03       ASTM  C29 
02/A04       ASTM  C40 
02/A07       ASTM  CI  17 
02/A09       ASTM  CI 27 


02/A10       ASTM  CI 28 
02/A12       ASTM  CI 36 
02/A15  ASTMD75 
02/A44       ASTM  C566 
Cement 

02/A17  ASTM  CI 09 
02/A22  ASTM  CI 83 
Concrete 

02/A01  ASTMC39 

02/A02       ASTM  C6 17 

02/A41       ASTM  CI 92 

02/A43       ASTM  CI 064 

02/GO 1       ASTM  C3 1 IC 1 72/C 1 43/C 1 3 8/C23 1 

Road  and  Paving  Materials 

02/M08      ASTM  D979 

02/M24      ASTM  D2041 

02/M25      ASTM  D2726 

Soil  and  Rock 

02/L02       ASTM  D422 

02/L04       ASTM  D698 

02/L06       ASTM  Dl  140 

02/L08       ASTM  Dl  557 

02/L13       ASTM  D2216 

02/L20  ASTMD4318 

Standard  Practices 

02/A39       ASTM  CI 077 

NVLAP  LAB  CODE  200012-0 

IPS  Corporation 

4593,  Hosohora  Ono,  Tatsuno-machi, 
Kamiina-gun,  Nagano-ken,  P.O.  Box  399-06 
Nagano  399-06 
JAPAN 

Contact:  Mr.  Takashi  Maruyama 
Phone:  +81-266-44-5200 
Fax:  +81-266-44-5300 
E-Mail:  maruyama@ips-emc.co.jp 
URL:  http://www.ips-emc.co.jp 

FCC  Test  Methods 

Accreditation  Valid  Through:  December  31,  1999 

NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AU ST  EL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 

Devices 

1. 2/FO  la      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

1 2/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 


NVLAP  1999  DIRECTORY  -  Page  D88 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  200013-0 

ENCORP 

615  North  Nash  Street,  Suite  203 
ElSegundo,  CA  90245 
Contact:  Mr.  Felix  Mateo 
Phone:  310-640-9811 
Fax:  310-640-9804 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  December  31,  1999 


NVLAP  LAB  CODE  200014-0 
Austin  Analytical  Laboratory 

2401  Holly  Street 

P.O.  Box  1088 

Austin,  TX  78767-8814 

Contact:  Mr.  Larry  K.  Mutschler 

Phone:  512-505-7842 

Fax:  512-505-7843 

E-Mail:  mutschler@electric.austin.tx.us 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  December  31,  1999 


NVLAP  LAB  CODE  200016-0 
Daybrite  Lighting  (Genlyte  Thomas  Group) 
Photometric  Laboratory 

1015  S.  Green  Street 

P.O.  Box  1687 

Tupelo,  MS  38802-1687 

Contact:  Dr.  David  W.  Knoble,  P.E. 

Phone:  601-842-7212 

Fax:  601-841-5596 


Energy  Efficient  Lighting  Products 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

Luminaires  (Lighting  Fixtures) 
22/F01  IESLM-10 
22/F03       IES  LM-35 
22/F04       IES  LM-41 
22/F05       IES  LM-46 


NVLAP  LAB  CODE  200017-0 
DOMUS  ITSL,  a  division  of  LGS  Group, 
Incorporated 

309  Cooper  Street,  5th  Floor 
Ottawa  Ontario  K2P  0G5 
CANADA 

Contact:  Mr.  Robert  Macdonald 
Phone:  613-230-6285  x339 
Fax:  613-230-3274 
E-Mail:  bob_macdonald@lgs.ca 
URL:  http://www.domus.com 

Cryptographic  Modules  Testing 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

1 7/CO 1       NIST-CSTT:  1 40- 1 ;  National  Institute  of 
Standards  and  Technology-Cryptographic 
Support  Test  Tool  (CSTT)  for  the  Federal 
Information  Processing  Standard  140-1  (FIPS 
140-1)  "Security  Requirements  for 
Cryptographic  Modules." 

1 7/CO  1  a     Test  Method  Group  1 :  All  test  methods  derived 
from  FIPS  140-1  and  specified  in  the  CSTT, 
except  those  listed  in  Group  2  and  Group  3. 

1 7/CO  1  b     Test  Method  Group  2:  Test  methods  for 

Physical  Security,  Level  4  derived  from  FIPS 
140-1  and  specified  in  the  CSTT 

17/C01c     Test  Method  Group  3:  Test  methods  for 

Software  Security,  Level  4  derived  from  FIPS 
140-1  and  specified  in  the  CSTT 

NVLAP  LAB  CODE  200018-0 

Test-Con  Incorporated 

80  Sand  Pit  Road 

P.O.  Box  31 16 

Danbury,  CT  06813-3116 

Contact:  Mr.  Chin  Okwuka 

Phone:  203-748-3012 

Fax:  203-778-0633 

E-Mail:  TestConlnc@aol.com 

Construction  Materials  Testing 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 
Aggregates 

02/A03       ASTM  C29 
02/A04       ASTM  C40 
02/A07       ASTM  CI  17 
02/A09       ASTM  CI 27 
02/A10       ASTM  CI 28 
02/A12       ASTM  CI 36 
02/A15  ASTMD75 
Cement 

02/A52       ASTM  CI 01 9 
Concrete 

02/A01  ASTMC39 


NVLAP  1999  DIRECTORY  -  Page  D89 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


A9TM  Pfil  7 

fP/A41 

uZ,/  rV-r  I 

r\o  1  1V1  ^  ]  UUH 

02/A45 

ASTM  C42 

02/G01 

ASTM  C3 1/C1 72/C 1 43/C 1 3  8/C23 1 

02/G02 

ASTM  CI 73 

Soil  and  Rock 

09/1  07 

t\<J  1  1V1  W+Z-il 

02/L04 

ASTM  D698 

02/L06 

ASTM  D 1140 

02/L07 

ASTM  D1556 

02/L08 

ASTM  D1557 

02/L16 

ASTM  D2487 

02/L17 

ASTM  D2488 

02/L20 

ASTMD4318 

02/L23 

ASTM  D2922 

02/L24 

ASTM  D2974 

02/L31 

ASTM  D2167 

Standard  Practices 

02/A38 

ASTM  E329 

02/A39 

ASTM  C1077 

NVLAP  LAB  CODE  200019-0 
EMSL  Analytical,  Inc. 

1001  SW  Klickitat  Way,  Suite  107 
Seattle,  WA  98134 
Contact:  Ms.  Carol  Evans 
Phone:  206-233-9007 
Fax:  206-233-9011 


Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  March  31,  1999 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  200020-0 
Hubbell  Lighting  Photometric  Laboratory 

2000  Electric  Way 

Christiansburg,  VA  24073-2502 

Contact:  Mr.  Robert  C.  Speck 

Phone:  540-382-611  1  x239 

Fax:  540-382-1544 

E-Mail:  rcspeck@hubbell-ltg.com 

URL:  www.hubbell-ltg.com/default.htm/photlab.html 

Energy  Efficient  Lighting  Products 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

Luminaires  (Lighting  Fixtures) 
22/F01  IESLM-10 
22/F02  IESLM-31 
22/F03  IES  LM-35 
22/F04  IES  LM-41 
22/F05       IES  LM-46 


NVLAP  LAB  CODE  200021-0 

Wayne  Langston,  Inc. 

P.O.  Box  1377 

League  City,  TX  77574-1377 
Contact:  Mr.  Wayne  Langston 
Phone:  281-337-6785 
Fax:  281-337-7217 
E-Mail:  langstoninc@msn.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 

1 2/FO 1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 

Devices 

1 2/FO  1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200024-0 
Enviro  Techniques,  Inc. 

22  California  Avenue 
Paterson,  NJ  07503 
Contact:  Mr.  Frank  Marino 
Phone:  973-684-0202 
Fax:  973-684-3007 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  September  30,  1999 


NVLAP  LAB  CODE  200025-0 
CHEMTEX  Environmental  Laboratory,  Inc. 

3082  25th  Street 
P.O.  Box  3922 
Port  Arthur,  TX  77642 
Contact:  Dr.  C.  N.  Reddy 
Phone:  409-983-4575 
Fax:  409-983-2126 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  1999  DIRECTORY  -  Page  D90 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  200027-0 
Vartest  Laboratories,  Inc. 

19  West  36th  Street,  10th  Floor 

New  York,  NY  10018-7909 

Contact:  Mr.  Adam  R.  Varley 

Phone:212-947-8391 

Fax: 212-947-8719 

E-Mail:  avarley@vartest.com 

URL:  http://www.vartest.com 

Carpet  and  Carpet  Cushion 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

Tests  Applicable  to  Carpet  and  Carpet  Cushion 
03/T0 1       AATCC  1 6  (Option  E) 
03/T02       ASTM  D2646  (Sees.  16-24) 
03/T04       1 6  CFR  Part  1 630  (FF- 1  -70) 
Tests  Applicable  to  Carpets 
03/G01       AATCC  20 
03/G02       AATCC  20A 
03/G04       AATCC  165 

NVLAP  LAB  CODE  200030-0 
Dodge-Regupol,  Inc.  Laboratory 

715  Fountain  Avenue 
P.O.  Box  989 

Lancaster,  PA  17608-0989 
Contact:  Mr.  Clyde  T.  Diffendall 
Phone:  717-295-3400  x262 
Fax:  717-295-3414 


Commercial  Products  Testing 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP 

Code 

Designation 

Plastics 

15/A23 

ASTM  D4 12  (Para.  17.2.2,  17.6) 

15/A24 

ASTM  D573 

15/A25 

ASTM  D624 

15/A26 

ASTM  D2240 

15/A30 

ASTM  D297  (Sec.  16;  Para.  16.3) 

NVLAP  LAB  CODE  200031-0 
Intertek  Testing  Services  NA  Inc. 

843 1  Murphy  Drive 
Middleton,  WI  53562 
Contact:  Mr.  Nigel  Stamp 
Phone:  608-836-4400 
Fax:  608-831-9279 
E-Mail:  nstamp@itsqs.com 
URL:  http://www.worldlab.com 


Thermal  Insulation  Materials 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

Thermal  Resistance 

01/T04  ASTMC236 

NVLAP  LAB  CODE  200032-0 
ITEK  Enviro  Services,  Inc. 

901  Grandview  Drive 

South  San  Francisco,  CA  94080-493 1 

Contact:  Ms.  Olivia  A.  Alejandro 

Phone:  650-952-8501 

Fax: 650-424-0336 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  200033-0 
3M  Product  Safety  EMC  Laboratory 

410  E.  Fillmore  Avenue 
Bldg  76-1-01 

St.  Paul.MN  55144-1000 

Contact:  Mr.  Greg  Demaray 

Phone:  612-736-4427 

Fax:  612-737-1035 

E-Mail:  gedemaray@mmm.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/F0 1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/F0 1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
12/F01b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

1 2/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 


NVLAP  1999  DIRECTORY  -  Page  D91 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  200034-0 
EMSL  Analytical,  Inc. 

Westwood  Business  Park  1801  Royal  Lane 

Suite  908 

Dallas,  TX  75229 

Contact:  Mr.  Thomas  A.  Schifani 

Phone:  972-831-9725 

Fax:  972-444-0884 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  200037-0 
Western  Analytical  Laboratory 

3017  N.  San  Fernando  Blvd.,  Suite  A 
Burbank,  CA  91504-4704 
Contact:  Mr.  Mike  Maladzhikyan 
Phone:  818-845-7766 
Fax:  818-845-7742 
E-Mail:  wal@pacificnet.net 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  200036-0 
Quest  Engineering  Solutions,  Inc. 

7  Sterling  Road 
P.O.  Box  125 
N.  Billerica,  MA  01862 
Contact:  Mr.  Glenn  Ryan 
Phone:  978-667-7000 
Fax:  978-667-3388 
E-Mail:  info@QES.com 
URL:  http://www.QES.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  March  31,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51        AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/F0 1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO 1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(C1SPR)  Methods 

12/CIS22    IEC/CISPR  22: 1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 


NVLAP  LAB  CODE  200039-0 
TUV  Telecom  Services,  Inc. 

1775  Old  Highway  8,  Suite  107/108 

St.  Paul,  MN  551  12-1891 

Contact:  Mr.  David  A.  Freemore 

Phone:  612-639-0775 

Fax:  612-639-0873 

E-Mail:  dreemore@earthlink.net 

URL:  http://www.detecon-us.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  March  31,  1999 
NVLAP 

Code  Designation 

AUSTEL  Technical  Standards  as  determined  under  the 
Telecommunications  Act  of  1991 

12/T47  TS-013 
12/T48  TS-014 
12/T49  TS-016 

Federal  Communications  Commission  (FCC)  Methods 
1 2/T01       Terminal  Equipment  Network  Protection 

Standards,  FCC  Method  -  47  CFR  Part  68  - 

Analog  and  Digital 
12/T01a      68.302  (Par.  c,d,e,f)  Environmental  simulation; 

68.304  Leakage  current  limit.;  68.306 

Hazardous  voltage  limit.;  68.308  Signal  power 

limit.;  68.310  Longitudinal  balance  limit.; 

68.312  On-hook  impedance  limit.;  68.314 

Billing  protection 
12/T01b     68.316  Hearing  Aid  Compatibility:  technical 

standards 

12/T01c      68.302  Environmental  simulation  (Par.  a,b) 


NVLAP  1999  DIRECTORY  -  Page  D92 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  200040-0 
LG  Electronics,  Inc.,  Quality  and  Reliability 
Center 

36,  Munlae-dong,  6-ga  Youngdungpo-gu 

Seoul  150-096 

KOREA 

Contact:  Mr.  Tae-Yeong  Oh 
Phone:  82  2  630  3008 
Fax:  82  2  630  3050 
E-Mail:  tyojlight@lge.co. la- 
FCC  Test  Methods 
Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51  AS/NZS3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  la      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
12/F01b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200041-0 
Kingston  Environmental  Laboratory 

1600  S.W.  Market 

Lee's  Summit,  MO  6408 1-3109 

Contact:  Ms.  Melissa  McKee 

Phone:  816-246-8746 

Fax:  816-251-8102 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  September  30,  1999 


NVLAP  LAB  CODE  200042-0 

PSI,  Inc. 

16601  West  Dakota  Street 
New  Berlin,  WI  53151-3540 
Contact:  Mr.  Jim  Updike 
Phone:  414-641-0911 
Fax:  414-641-0918 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  December  31,  1999 


NVLAP  LAB  CODE  200044-0 
U.S.  Army  Center  for  Health  Promotion  and 
Preventive  Medicine 

Attn:  MCHB-TS-L,  Bldg.  E-2100 

5158  Blackhawk  Road 

Aberdeen  Proving  Ground,  MD  21010-5422 

Contact:  Ms.  Rosemary  Gaffney 

Phone:  410-436-2208 

Fax:  410-436-8315 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  September  30,  1999 


NVLAP  LAB  CODE  200045-0 
Willamette  Industries,  Inc.  West  Coast 
Development  Lab 

9130  SW  Pioneer  Court,  Suite  D 
Wilsonville,  OR  97070 
Contact:  Mr.  Gary  Vosler 
Phone:  503-682-4995 
Fax:  503-682-4545 
E-Mail:  gvosler@wii.com 

Commercial  Products  Testing 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

Paper  and  Related  Products 

09/E02  TAPPI  T402-OM;  ASTM  D685 

09/E05  TAPPI  T410-OM 

09/E06  TAPPI  T411-OM 

09/E1 1  TAPPI  T452-OM 

09/E17  TAPPI  T494-OM 

09/E20  TAPPI  T809-OM 

09/E21  TAPPI  T818-OM 

09/E22  TAPPI  T807-OM 

09/E25  TAPPI  T826-PM 

09/E27  TAPPI  UM-403 

09/E29  TAPPI  T476-OM  


NVLAP  1999  DIRECTORY  -  Page  D93 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


09/HO 1  ASTM  D642;  TAPPI  T804-OM 

09/H24  TAPPI  T802-OM 

09/H28  TAPPI  T810-OM 

09/H29  TAPPI  T811-OM 

09/H30  TAPPI  T821-OM   

NVLAP  LAB  CODE  200046-0 
Maxim  Technologies,  Inc. 

662  Cromwell  Avenue 
St.  Paul,  MN  55114-1776 
Contact:  Mr.  Richard  S.  Alberg 
Phone:  612-659-7528 
Fax: 612-659-7229 

E-Mail:  RALBERG.STPAUL@MAXIMMAIL.COM 

Thermal  Insulation  Materials 

Accreditation  Valid  Through:  March  31,  1999 
NVLAP 

Code  Designation 

Mass,  Density,  and  Dimensional  Stability 

01/D03       ASTM  C209  (Sec.  6) 

01/D04       ASTM  C209  (Sec.  13) 

01/D05       ASTM  C209  (S.  13)  by  D1037  (S.  100-106) 

01/D06       ASTM  C209  (S.  14)  by  D1037  (S.  107-1 10) 

01/D07  ASTMC272 

01/D18       ASTM  D1622 

01/D19       ASTM  D2126 

Related  Material  Properties 


01/V04 

ASTM  E96 

Strength 

01/S02 

ASTM  C203 

01/S03 

ASTM  C209  (Sec.  9) 

01/S04 

ASTM  C209  (Sec.  10) 

01/S05 

ASTM  C209  (Sec.  1 1 ) 

01/S06 

ASTM  C209  (Sec.  12) 

01/S1 1 

ASTM  D1621  (Proc.  A) 

Thermal 

Resistance 

01/T06 

ASTM  C518 

Acoustical  Testing  Services 

Accreditation  Valid  Through:  March  31,  1999 
NVLAP 

Code  Designation 

08/P03  ASTM  C423  (ISO  354) 

08/P06  ASTM  E90  (ISO  140,  Part  3) 

08/P10  ANSI  S12. 31  (ISO  3741) 

08/P31  ASTME336 

08/P32  ASTM  El 007 

08/P37  ASTM  E966 


NVLAP  LAB  CODE  200047-0 
National  Econ  Corporation 

4515  Poplar  Avenue,  Suite  410 
Memphis,  TN  38117 
Contact:  Mr.  Chester  V.  Ervin 
Phone:  901-761-5431 
Fax:  901-767-2466 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  September  30,  1999 


NVLAP  LAB  CODE  200049-0 
Intertek  Testing  Services  NA,  Inc. 

7435  4th  Street  North 
Oakdale,  MN  55128 
Contact:  Mr.  Albert  Garlatti 
Phone:  612-730-1188 
Fax: 612-730-1282 
E-Mail:  agarlatti@itsqs.com 
URL:  http://www.worldlab.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AU ST  EL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/F0 la      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
12/F01b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

1 2/CIS22    IEC/CISPR  22: 1 993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200050-0 
Cooper  Lighting  -  Metalux  Research  Laboratories 

1 101  Southerfield  Road 

P.O.  Box  1207 

Amencus,  GA  31709-1207 

Contact:  Mr.  Gregory  B.  Bacon 

Phone:  770-486-4579 

Fax:  770-486-4599 


URL:  http://www.cooperlighting.com/metalux/ 

Energy  Efficient  Lighting  Products 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Luminaires  (Lighting  Fixtures) 
22/F04  IESLM-41 


NVLAP  1999  DIRECTORY  -  Page  D94 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  200051-0 
Analytical  Environmental  Services  International, 
Inc. 

Coll  Y  Toste  50,  St.  3A 
HatoRey,  PR  00918 
Contact:  Mr.  Ady  Padan 
Phone:  787-753-3431 
Fax:  787-281-6669 
E-Mail:  YOTAl@MSN.COM 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  December  31,  1999 


NVLAP  LAB  CODE  200052-0 
Dell  Regulatory  Test  Laboratories 

One  Dell  Way 

Round  Rock,  TX  78682 

Contact:  Mr.  David  Staggs 

Phone:  512-728-3751 

Fax: 512-728-3653 

E-Mail:  David_Staggs@us.dell.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/F0 1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

12/F01a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
12/F01b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

1 2/CIS22    IEC/CISPR  22: 1 993 :  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

Acoustical  Testing  Services 

Accreditation  Valid  Through:  September  30,  1999 

NVLAP 

Code  Designation 

08/P24  ANSI  S 1 2. 1 0  (ISO  7779) 

08/P40  ISO  9296 

08/P41  ECMA74 

08/P42  ECMA  109 


NVLAP  LAB  CODE  200053-0 
MagneTek  (Lexington)  Engineering  Laboratory 

669  Natchez  Trace  Drive 
Lexington,  TN  38351-4198 
Contact:  Mr.  Hugh  Fesmire 
Phone:  901-968-4274  x429 
Fax:  901-968-4164 

E-Mail:  hugh_fesmire@magnetek.com 

Efficiency  of  Electric  Motors 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

24/M01      IEEE  112,  Method  B  

NVLAP  LAB  CODE  200054-0 
Micro  Analytical  Laboratories,  Inc. 

1786  -  18th  Street,  Suite  A 

San  Francisco,  C A  94107-2343 

Contact:  Mr.  Frank  Raviola 

Phone:  510-653-0824 

Fax:  510-653-1361 

E-Mail:  microlab@labmicro.com 

URL:  http://www.labmicro.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  September  30,  1999 

NVLAP  LAB  CODE  200055-0 
Celestica  International  Inc. 

844  Don  Mill  Road 

North  York,  Ontario  M3C  1 V7 

CANADA 

Contact:  Mr.  Kenneth  Long 

Phone:  416-448-4937 

Fax: 416-448-4924 

E-Mail:  klong@celestica.com 

URL:  http://www.celestica.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

AUSTEL  Technical  Standards  as  determined  under  the 
Telecommunications  Act  of  1991 

12/T41  TS-001 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T50       AS/NZS  3260 


NVLAP  1999  DIRECTORY  -  Page  D95 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  200056-0 
EMSL  Analytical,  Inc. 

440  Lawrence  Bell  Drive,  Suite  #2 
Williamsville,  NY  14221 
Contact:  Mr.  Kenneth  J.  Najuch 
Phone:  716-631-5887 
Fax:  716-631-7693 
E-Mail:  knajuch@aol.com 
URL:  http://www.emsl.com/ 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  June  30,  1999 

NVLAP  LAB  CODE  200057-0 

Curtis-Straus  LLC 

527  Great  Road 

Littleton,  MA  01460 

Contact:  Mr.  Jon  D.  Curtis 

Phone:  978-486-8880 

Fax:  978-486-8828 

E-Mail:  jdc@world.std.com 

URL:  http://world.stds.com/~csweb 

FCC  Test  Methods 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

AUSTEL  Technical  Standards  as  determined  under  the 
Telecommunications  Act  of  1991 

12/T41  TS-001 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T50  AS/NZS  3260 
12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 

1 2/FO 1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

12/F01a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  1  b      Radiated  Emissions 
12/T01        Terminal  Equipment  Network  Protection 

Standards,  FCC  Method  -  47  CFR  Part  68  - 

Analog  and  Digital 
12/T01a      68.302  (Par.  c,d,e,f)  Environmental  simulation; 

68.304  Leakage  current  limit.;  68.306 

Hazardous  voltage  limit.;  68.308  Signal  power 

limit.;  68.310  Longitudinal  balance  limit.; 

68.312  On-hook  impedance  limit.;  68.314 

Billing  protection 
12/T01b     68.3 16  Hearing  Aid  Compatibility:  technical 

standards 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 


equipment 

NVLAP  LAB  CODE  200058-0 
Compaq  Computer  Corp.  Emissions  Control  Lab 

M/C  060607 
P.O.  Box  692000 
Houston,  TX  77070-2000 
Contact:  Mr.  Steve  Ortmann 
Phone:  281-514-4897 
Fax:  281-514-8029 

E-Mail:  Steve. Ortmann@Compaq. Com 
FCC  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

AUSTEL  Technical  Standards  as  determined  under  the 
Telecommunications  Act  of  1991 

12/T41  TS-001 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T50  AS/NZS  3260 
12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO  1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200059-0 

Northwest  EMC,  Inc. 

120  South  Elliott  Road 

Newberg,  OR  97132 

Contact:  Mr.  Dean  Ghizzone 

Phone:  503-537-0728 

Fax:  503-537-0735 

E-Mail:  dghizzone@nwemc.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 

1 2/FO  1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 


NVLAP  1999  DIRECTORY  -  Page  D96 


(See  'How  To  Use  This  Directory*  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200061-0 
Rhein  Tech  Laboratories,  Inc. 

360  Herndon  Parkway,  Suite  #1400 

Herndon.VA  20170-4824 

Contact:  Mr.  Bruno  Clavier 

Phone:  703-689-0368 

Fax:  703-689-2056 

E-Mail:  bclavier@rheintech.com 

URL:  http://www.rheintech.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/F0 1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO 1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
12/F01b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22: 1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200062-0 
Professional  Testing  (EMI),  Inc. 

1601  FM  1460,  Suite  B 
Round  Rock,  TX  78664 
Contact:  Mr.  Jeffrey  A.  Lenk 
Phone:  512-244-3371 
Fax:  512-244-1846 
E-Mail:  jlenk@ptitest.com 
URL:  http://www.ptitest.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO  1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 


International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

1 2/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200063-0 
Compatible  Electronics,  Inc. 

2337  Troutdale  Drive 

Agoura,  CA  91301 

Contact:  Mr.  Jeff  Klinger 

Phone:  818-597-0600 

Fax:  818-597-1187 

E-Mail:  jklinger@celectronics.com 

URL:  http://celectronics.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

AUSTEL  Technical  Standards  as  determined  under  the 
Telecommunications  Act  of  1991 
12/T41  TS-001 
12/T42  TS-002 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T50  AS/NZS  3260 
12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO  1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  la      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 
12/T01       Terminal  Equipment  Network  Protection 

Standards,  FCC  Method  -  47  CFR  Part  68  - 

Analog  and  Digital 
12/T01a      68.302  (Par.  c,d,e,f)  Environmental  simulation; 

68.304  Leakage  current  limit;  68.306 

Hazardous  voltage  limit.;  68.308  Signal  power 

limit.;  68.310  Longitudinal  balance  limit.; 

68.312  On-hook  impedance  limit.;  68.314 

Billing  protection 
12/T01b     68.316  Hearing  Aid  Compatibility:  technical 

standards 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

1 2/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 


NVLAP  1999  DIRECTORY  -  Page  D97 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  200064-0 
Compliance  Engineering  Services,  Inc.  -  Taiwan 

1366  Bordeaux  Drive 
Sunnyvale,  CA  94089-1005 
Contact:  Mr.  Scott  Wang 
Phone:  408-752-8166  xl  16 
Fax:  408-752-8168 


FCC  Test  Methods 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/F0 1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/F0 1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
12/F01b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200065-0 
Compliance  Eng.  Svces,  Inc.,  Compliance 
Certification  Services 

1366  Bordeaux  Drive 
Sunnyvale,  CA  94089-1005 
Contact:  Mr.  Scott  Wang 
Phone:  408-752-8166  x116 
Fax:  408-752-8168 


FCC  Test  Methods 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

1 2/CIS22    IEC/CISPR  22: 1 993 :  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 


equipment 

NVLAP  LAB  CODE  200066-0 
Washington  Laboratories,  Ltd. 

7560  Lindbergh  Drive 
Gaithersburg,  MD  20879 
Contact:  Mr.  Michael  F.  Violette 
Phone:  301-417-0220 
Fax: 301-417-9069 
E-Mail:  mikev@wll.com 
URL:  http://www.wll.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 

NVLAP 

Code  Designation 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO  1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
12/F01b      Radiated  Emissions 

NVLAP  LAB  CODE  200067-0 
CT&E  Environmental  Services  Inc. 

3491  Kurtz  Street 
San  Diego,  CA  92110 
Contact:  Mr.  Craig  Sobotka 
Phone:  619-222-0544 
Fax:  619-224-7260 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  September  30,  1999 


NVLAP  LAB  CODE  200068-0 
EMC  Compliance  Mgmt  Group,  dba  Turntech 
Scientific  &  Instr.,  Inc. 

670  National  Avenue 

Mountain  View,  CA  94043-2244 

Contact:  Mr.  Paul  F.  Chen 

Phone:  650-988-0900 

Fax:  650-988-6647 

E-Mail:  pfchen@emc-turntech.com 

URL:  http://www.emc-turntech.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO  1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

12/F01a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 


NVLAP  1999  DIRECTORY  -  Page  D98 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200069-0 
Elliott  Laboratories,  Inc. 

684  West  Maude  Avenue 
Sunnyvale,  CA  94086-3518 
Contact:  Mr.  Thomas  H.  Parker 
Phone:  408-245-7800  x236 
Fax:  408-245-3499 
E-Mail:  tparker@elliottlabs.com 
URL:  http://www.elliottlabs.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

AUSTEL  Technical  Standards  as  determined  under  the 
Telecommunications  Act  of  1991 
12/T41  TS-001 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T50  AS/NZS  3260 
12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
12/F01       FCC  Method  -  47  CFR  Part  15  -  Digital 
Devices 

12/F01a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
12/F01b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200070-0 
EMC  Kashima  Corporation 

1614  Mushihata,  Omigawa-machi 

Katori-gun, 

Chiba-ken  289-0341 

JAPAN 

Contact:  Mr.  Masaru  Nakayama 

Phone:  478-82-0963 

Fax:  478-82-3373 

E-Mail:  emc@emc-kashima.co.jp 

FCC  Test  Methods 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 


Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
12/F01       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

12/F01a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
12/F01b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200071-0 
Apple  Computer,  Inc.,  EMC  Compliance 
Laboratory 

1  Infinite  Loop,  Mailstop  26-A 

Cupertino,  CA  95014-2084 

Contact:  Mr.  Robert  Steinfeld 

Phone:  408-974-2618 

Fax:  408-862-5061 

E-Mail:  steinfel@apple.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/F0 1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO 1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

1 2/CIS22    IEC/CISPR  22: 1 993 :  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200074-0 
Product  Safety  Engineering,  Inc. 

12955  Bellamy  Brothers  Blvd. 
Dade  City,  FL  33525-7908 
Contact:  Mr.  Dale  E.  Burns 
Phone:  813-989-2360 
Fax:  813-989-2373 
E-Mail:  dburns@pseinc.com 
URL:  http://www.pseinc.com 


NVLAP  1999  DIRECTORY  -  Page  D99 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


FCC  Test  Methods 

Accreditation  Valid  Through:  March  31,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51        AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 

1 2/FO 1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  la      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  1  b      Radiated  Emissions 
12/T01       Terminal  Equipment  Network  Protection 

Standards,  FCC  Method  -  47  CFR  Part  68  - 

Analog  and  Digital 
12/T01a      68.302  (Par.  c,d,e,f)  Environmental  simulation; 

68.304  Leakage  current  limit.;  68.306 

Hazardous  voltage  limit.;  68.308  Signal  power 

limit.;  68.310  Longitudinal  balance  limit.; 

68.3 1 2  On-hook  impedance  limit.;  68.3 14 

Billing  protection 
12/T01b     68.316  Hearing  Aid  Compatibility:  technical 

standards 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200076-0 
Instrument  Specialties  Co.,  Inc. 

P.O.  Box  650,  Shielding  Way 
Delaware  Water  Gap,  PA  18327-0136 
Contact:  Mr.  J.  Fred  Gardner 
Phone:717-424-8510 
Fax:  717-421-4227 

E-Mail:  fred_gardner@instrumentspecialties.com 
URL:  http://www.instrumentspecialties.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO  1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 


NVLAP  LAB  CODE  200077-0 
Taiwan  Tokin  EMC  Eng.  Corp. 

9th  Fl.,  No.  38,  Fushing  N.  Rd. 

Taipei 

TAIWAN 

Contact:  Mr.  Steven  Chang 
Phone:  886-2-26092415 
Fax:  886-2-26099303 
E-Mail:  ttemc@tptsl  .seed.net.tw 

FCC  Test  Methods 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO  1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  1  b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200078-0 
Compaq  Computer  Corp.  EMC  Test  Facility 

301  Rockrimmon  Blvd.  South 
Colorado  Springs,  CO  80919-2398 
Contact:  Mr.  Dennis  Laurence 
Phone:  719-548-2080 
Fax:  719-548-2070 


FCC  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO  1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 


NVLAP  1999  DIRECTORY  -  Page  D100 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  200079-0 
Sporton  International,  Inc. 

6F,  No.  106,  Sec.  1,  Hsin  Tai  Wu  Road 
Hsi  Chih 
Taipei  Hsien 
TAIWAN 

Contact:  Mr.  W.  L.  Huang 
Phone:  886-2-2696-2468 
Fax:  886-2-2696-2255 


FCC  Test  Methods 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

1 2/CIS22    IEC/CISPR  22: 1 993 :  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200080-0 
Continental  Envirotech,  Inc. 

646  West  Broadway  Road,  Suite  401 
Mesa,  AZ  85210-1212 
Contact:  Mr.  Stephen  P.  Kovac 
Phone:  602-844-1710 
Fax:  602-844-1752 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  September  30,  1999 


NVLAP  LAB  CODE  200081-0 
Advanced  Energy,  Industrial  Energy  Laboratory 

909  Capability  Drive,  #2100 
Raleigh,  NC  27606-3870 
Contact:  Mr.  Jeffrey  L.  Farlow 
Phone:  919-857-9013 
Fax:  919-832-2696 
E-Mail:  jfarlow@aec.ncsu.edu 
URL:  http://www.aec.ncsu.edu 


Efficiency  of  Electric  Motors 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

24/M01      IEEE  112,  Method  B  

NVLAP  LAB  CODE  200082-0 

PDE  Laboratories 

950  Calle  Negocio 

San  Clemente,  CA  92673-6201 

Contact:  Mr.  Dave  Farrant 

Phone:  949-361-9189 

Fax:  949-361-9597 

E-Mail:  testsvcs@pdelabs.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO  1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

1 2/CIS22    IEC/CISPR  22: 1 993 :  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200083-0 
Testwell  Laboratories,  Inc./Testwell  Industries, 
Inc. 

47  Hudson  Street 
Ossining,NY  10562 
Contact:  Mr.  V.  Reddy  Kancharla 
Phone:  914-762-9000 
Fax:  914-762-9638 

URL:  http://www.testwellcraig.com 

Construction  Materials  Testing 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 
Admixtures 

02/A35       ASTM  C233 
Aggregates 

02/A03       ASTM  C29 
02/A04       ASTM  C40 
02/A06       ASTM  C88 
02/A07       ASTM  CI  17 
02/A09       ASTM  CI 27 
02/A10       ASTM  CI 28 


NVLAP  1999  DIRECTORY  -  Page  D101 


(See  *How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


02/A11  ASTMC131 

02/A12  ASTMC136 

02/A13  ASTMC142 

02/A15  ASTMD75 

02/A44  ASTM  C566 

02/A46  ASTM  C535 
Cement 

021  Ml  ASTM  CI 09 

02/A18  ASTM  CI  14 

02/A21  ASTM  CI 57 

02/A22  ASTM  CI 83 

02/A26  ASTM  C191 

02/A31  ASTMC305 
Concrete 

02/A01  ASTMC39 

02/A02  ASTM  C6 17 

02/A40  ASTM  C78 

02/A41  ASTM  CI 92 

02/A43  ASTM  CI 064 

02/A45  ASTM  C42 

02/A48  ASTM  C856 

02/G0 1  ASTM  C3 1/C 1 72/C 1 43/C 1 3  8/C23 1 

Soil  and  Rock 

02/L02  ASTM  D422 

02/L04  ASTM  D698 

02/L05  ASTM  D854 

02/L06  ASTM  Dl  140 

02/L07  ASTM  D 1556 

02/L08  ASTM  D 1557 

02/L13  ASTM  D2216 

02/L16  ASTM  D2487 

02/L17  ASTM  D2488 

02/L20  ASTMD4318 

02/L23  ASTM  D2922 

02/L24  ASTM  D2974 

02/L25  ASTM  D3017 

Standard  Practices 

02/A38  ASTM  E329 

02/A39  ASTM  CI 077 

Steel  Materials 

02/S01  ASTM  A370  (Sec.  5-13)/E8 

02/S07  ASTM  E709 

02/S08  ASTM  El 65 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  200084-0 
Windermere  Info.  Tech.  Sys. 
Military/Commercial  Compliance  Lab. 

401  Defense  Highway 
Annapolis,  MD  21401 
Contact:  Mr.  Douglas  G.  Frazee 
Phone:  410-266-1793 
Fax:  410-266-1751 

E-Mail:  dfrazee@windermeregroup.com 

URL:  http://www.windermeregroup.com/mcl/index.html 

FCC  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  1  b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200085-0 
Global  EMC  Standard  Tech.  Corp. 

No.  3,  Pau-Tou-Tsuo  Valley 
Chia-Pau  Tsuen,  Lin  Kou  Hsiang 
Taipei  County 
TAIWAN 

Contact:  Mr.  Raymond  Chang 

Phone:  886-2-26035321 

Fax:  886-2-26035325 

E-Mail:  GESTEK@MS5.HINET.NET 

FCC  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO  1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/F0 la      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 


NVLAP  1999  DIRECTORY  -  Page  D102 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

1 2/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200086-0 
Radiation  Technology,  Inc. 

424  Roberson  Lane 
San  Jose,  CA  95112 
Contact:  Mr.  John  Howard 
Phone:  408-441-6077 
Fax:  408-441-6078 
E-Mail:  RADEMI@AOL 

FCC  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
12/F01       FCC  Method  -  47  CFR  Part  15  -  Digital 
Devices 

12/F01a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
12/F01b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200087-0 

Rogers  Labs,  Inc. 

4405  W.  259th  Terrace 
Louisburg,  KS  66053 
Contact:  Mr.  Scot  D.  Rogers 
Phone:  913-837-3214 
Fax:  913-837-3214 
E-Mail:  rogerslb@sound.net 

FCC  Test  Methods 

Accreditation  Valid  Through:  March  31,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51  AS/NZS3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

12/F01a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 


International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200088-0 
Toshiba/Houston  Test  Laboratory 

13131  W.  Little  York  Road 
Houston,  TX  77041-5807 
Contact:  Mr.  Willard  Gray 
Phone:  713-466-0277 
Fax:  713-466-8773 


Efficiency  of  Electric  Motors 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

24/M01      IEEE  112,  Method  B 

NVLAP  LAB  CODE  200089-0 
Electronic  Compliance  Laboratories,  Inc. 

1249  Birchwood  Drive 
Sunnyvale,  CA  94089 
Contact:  Mr.  Chris  Byleckie 
Phone:  408-747-1490 
Fax:  408-747-1495 
E-Mail:  chris@eclabs.com 
URL:  http://www.eclabs.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  March  31,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO  1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  la      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  1  b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22: 1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 


NVLAP  1999  DIRECTORY  -  Page  D103 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  200090-0 
ProScience  Analytical  Services,  Inc. 

22  Cummings  Park 
Woburn,  MA  01801-2122 
Contact:  Mr.  Adrian  Stanca 
Phone:  781-935-3212 
Fax:  781-932-4857 
E-Mail:  PASI96@aol.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  December  31,  1999 


Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  December  31,  1999 


NVLAP  LAB  CODE  200091-0 
IBM  Rochester  EMC  Lab 

3605  North  Highway  52,  Department  5 1 5 

Rochester,  MN  55901-7829 

Contact:  Mr.  John  S.  Maas 

Phone:  507-253-2426 

Fax:  507-253-1317 

E-Mail:  johnmaas@us.ibm.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  la      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
12/F01b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 


NVLAP  LAB  CODE  200092-0 
EMCE  Engineering,  Inc. 

44366  South  Grimmer  Boulevard 

Fremont,  CA  94538-6385 

Contact:  Mr.  Stephen  A.  Sawyer 

Phone:  510-490-4307 

Fax: 510-490-3441 

E-Mail:  EMCEEngrg@aolcom 

FCC  Test  Methods 

Accreditation  Valid  Through:  December  31,  1999 

NVLAP 

Code  Designation 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO  1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/F0 1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 
1 2/TO 1       Terminal  Equipment  Network  Protection 

Standards,  FCC  Method  -  47  CFR  Part  68  - 

Analog  and  Digital 
1 2/TO  la      68.302  (Par.  c,d,e,f)  Environmental  simulation; 

68.304  Leakage  current  limit.;  68.306 

Hazardous  voltage  limit.;  68.308  Signal  power 

limit.;  68.310  Longitudinal  balance  limit.; 

68.312  On-hook  impedance  limit.;  68.314 

Billing  protection 
1 2/TO  1  b     68.316  Hearing  Aid  Compatibility:  technical 

standards 

12/TOlc      68.302  Environmental  simulation  (Par.  a,b) 

NVLAP  LAB  CODE  200093-0 
UltraTech  Engineering  Labs  Inc. 

33-4181  Sladeview  Crescent 
Mississauga,  Ontario  L5L  5R2 
CANADA 

Contact:  Mr.  Victor  Kee 

Phone:  905-569-2550 

Fax:  905-569-2480 

E-Mail:  vhk.ultratech@sympatico.ca 

FCC  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 

NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO  1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 


NVLAP  1999  DIRECTORY  -  Page  D104 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

1 2/CIS22    IEC/CISPR  22 : 1 993 :  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200094-0 
EMC  International,  Inc. 

762  Park  Avenue 
Youngsville,  NC  27596 
Contact:  Mr.  Dale  S.  Albright 
Phone:  919-554-0901 
Fax:  919-556-2043 
E-Mail:  emcamerica@aol.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51  AS/NZS3548 

Federal  Communications  Commission  (FCC)  Methods 
12/F01       FCC  Method  -  47  CFR  Part  15  -  Digital 
Devices 

12/F01a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
12/F01b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

1 2/CIS22    IEC/CISPR  22: 1 993 :  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200095-0 

Chopra-Lee,  Inc. 

1815  Love  Road 
P.O.  Box  567 

Grand  Island,  NY  14072-0567 

Contact:  Mr.  Paul  S.  Chopra 

Phone:  716-773-7625 

Fax:  716-773-7624 

E-Mail:  pschopra@msn.com 

URL:  http://www.chopra-lee-inc.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  December  31,  1999 


Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  December  31,  1999 


NVLAP  LAB  CODE  200096-0 

Key  Tronic  Corp. 

4424  N.  Sullivan  Road 

P.O.  Box  14687 

Spokane,  WA  99214-0687 

Contact:  Mr.  Robert  E.  Schwartz 

Phone:  509-927-5274 

Fax:  509-927-5258 

E-Mail:  bschwart@keytronic.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  March  31,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51  AS/NZS3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  la      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

1 2/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200097-0 
PEP  Testing  Laboratory 

12-3  FL.  No.  27-1, Lane  169,  Kang  Ning  St 

Hsi-Chi 

Taipei  Hsien 

TAIWAN 

Contact:  Mr.  Peter  Kao 

Phone:  886-2-2692-2097 

Fax:  886-2-2695-6236 

E-Mail:  peplab@top2.ficnet.net.tw 

FCC  Test  Methods 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO  1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  la      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 


NVLAP  1999  DIRECTORY  -  Page  D105 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200098-0 
Northern  Telecom  BY  VV  Lab 

250  Sidney  Street 
Belleville,  Ontario  K8N5B7 
CANADA 

Contact:  Mrs.  Seham  Fawzy 
Phone:  613-966-0100  x3145 
Fax:  613-967-5364 


FCC  Test  Methods 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  A  USTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  la      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  1  b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200099-0 
Spectrum  Research  &  Testing  Laboratory,  Inc. 

No.  101-10,  Ling  8,  Shan-Tong  Li 

Chung-Li,  Taoyuan 

TAIWAN 

Contact:  Mr.  Cheng-Yang  Ho 
Phone:  01  1-886-3-4987684 
Fax:  01  1-886-3-4986528 
E-Mail:  info@srtlab.com 
URL:  http://vvfww.srtlab.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO  1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  la      Conducted  Emissions,  Power  Lines,  450  KHz 


to  30  MHz 
1 2/FO  1  b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

1 2/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200101-0 
Fountain  Compliance  Laboratory 

50  Randolph  Road 
Somerset,  NJ  08873-1240 
Contact:  Mr.  Wei  Li 
Phone:  732-560-9010 
Fax:  732-560-9173 
E-Mail:  lee@ftn.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  March  31,  1999 

NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO  1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 

Devices 

1 2/FO  la      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200102-0 
Advance  Data  Technology  Corporation 

No.  47,  14  Ling,  Chia  Pau  Tsuen, 
Lin  Kou  Hsiang 
Taipei  Hsien 
TAIWAN 

Contact:  Mr.  Harris  W.  Lai 
Phone:  886-2-6032180 
Fax:  886-2-6022943 
E-Mail:  harris@mail.adt.com.tw 

FCC  Test  Methods 

Accreditation  Valid  Through:  December  31,  1999 

NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 


NVLAP  1999  DIRECTORY  -  Page  D106 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Federal  Communications  Commission  (FCC)  Methods 
12/F01       FCC  Method  -  47  CFR  Part  15  -  Digital 
Devices 

12/F01a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
12/F01b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200103-0 
Hayes  Microcomputer  Products,  Inc. 

P.O.  Box  105203 
Atlanta,  GA  30348-5203 
Contact:  Mr.  Bill  Mason 
Phone:  770-840-9200 
Fax:  770-447-0178 


FCC  Test  Methods 

Accreditation  Valid  Through:  March  31,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/F0 1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

12/F01a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
12/F01b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

1 2/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200104-0 
Asbestos  TEM  Laboratories,  Inc. 

952  Greg  Street 

Sparks,  NV  89431 

Contact:  Mr.  R.  Mark  Bailey 

Phone:  510-528-0108 

Fax:  510-528-0109 

E-Mail:  MBaileyASB@aol.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  December  31,  1999 


NVLAP  LAB  CODE  200107-0 
Toshiba  Corp.,  Ome  Works 

2-9  Suehiro-cho 
Ome  Tokyo  198-8710 
JAPAN 

Contact:  Mr.  N.  Tsumura 
Phone: 81-428-33-1170 
Fax:  81-428-30-7911 


FCC  Test  Methods 

Accreditation  Valid  Through:  March  31,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  la      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
12/F01b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

1 2/CIS22    IEC/CISPR  22 : 1 993 :  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200109-0 
A-Pex  International  Co.,  Ltd.  Yokowa  Laboratory 

108  Yokowa-cho,  Ise-shi 

Mie-ken516-1106 

JAPAN 

Contact:  Mr.  Michihisa  Yamazaki 

Phone:  81-596-24-6717 

Fax:  81-596-27-5631 

E-Mail:  yamazaki@a-pex.co.jp 

URL:  http://www.a-pex.co.jp 

FCC  Test  Methods 

Accreditation  Valid  Through:  March  31,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO  1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

12/F01a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
12/F01b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22: 1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 


NVLAP  1999  DIRECTORY  -  Page  D107 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200111-0 
TUV  Rheinland  of  North  America,  Inc. 

12  Commerce  Road 
Newtown,  CT  06470-1607 
Contact:  Mr.  Timothy  M.  Dwyer 
Phone:  203-426-0888  x104 
Fax:  203-270-8883 

URL:  http://www.us.tuv.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  la      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

1 2/CIS22    IEC/CISPR  22: 1 993 :  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200112-0 

IBM  Austin  EMC 

1 1400  Burnet  Road,  M.S.  4469 
Austin,  TX  78758-3493 
Contact:  Mr.  Jerry  W.  Scibielski 
Phone:  512-838-5816 
Fax:  512-838-7101 
E-Mail:  scib@us.ibm.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO  1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  1  b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

1 2/CIS22    IEC/CISPR  22: 1 993 :  Limits  and  methods  of 
measurement  of  radio  disturbance 


characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200114-0 

Cisco  Systems,  Inc. 

1 70  West  Tasman  Drive 
San  Jose,  CA  95134-1706 
Contact:  Mr.  Andrew  Griffin 
Phone:  408-527-1810 
Fax:  408-526-4184 
E-Mail:  agriffin@cisco.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  March  31,  1999 

NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO  1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22: 1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200116-0 

Nemko  EESI,  Inc. 

1 1696  Sorrento  Valley  Road,  Suite  F 

San  Diego,  CA  92121 

Contact:  Mr.  Harry  H.  Hodes 

Phone: 619-259-4952 

Fax:  619-259-7170 

E-Mail:  techops@eesi.com 

URL:  http://www.eesi.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  December  31,  1999 

NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51  AS/NZS3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO  1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 


NVLAP  1999  DIRECTORY  -  Page  D108 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200117-0 
Universal  Compliance  Laboratories 

775  B  Mabury  Road 
San  Jose,  CA  95133 
Contact:  Mr.  Bob  Cole 
Phone:  408-453-8744 
Fax:  408-453-8747 
E-Mail:  bob_ucl@msn.com 
URL:  http://www.usll.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  March  31,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AU ST  EL 
Technical  Standards 

12/T51  AS/NZS3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

12/F01a      Conducted  Emissions,  Power  Lines,  450  KHz 
to  30  MHz 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200118-0 
Electronic  Research  &  Service  Organization/ITRI 

K500Bldg  17,  195  Sec.  4 
Chung  Hsing  Road,  Chutung 
Hsinchu 
TAIWAN 

Contact:  Mr.  Paul  Y.  Liau 
Phone:  886-3-591-5994 
Fax:  886-3-582-7520 
E-Mail:  PYLA@erso.itri.org.tw 

FCC  Test  Methods 

Accreditation  Valid  Through:  March  31,1 999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO  1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

12/F01a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 


International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200119-0 
Garwood  Laboratories,  Inc. 

565  Porter  Way 

Placentia,  CA  92870-6454 

Contact:  Mr.  Robert  Lynch 

Phone:  714-572-2027 

Fax:  714-572-2025 

E-Mail:  bobl.garwoodtestlabs.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO  1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  la      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
12/F01b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200120-0 
Chemitox  EMC  Research,  Inc. 

14979,  Egusa,  Sudama-cho,  Kitakoma-gun 

Yamanashi-ken  408-01 

JAPAN 

Contact:  Mr.  Kohichi  Nakayama 
Phone:  81-551-42-4411 
Fax:  81-551-20-6002 


FCC  Test  Methods 

Accreditation  Valid  Through:  March  31,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO  1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  la      Conducted  Emissions,  Power  Lines,  450  KHz 
to  30  MHz 


NVLAP  1999  DIRECTORY  -  Page  D109 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200121-0 
Cabletron  Systems,  Inc. 

35  Industrial  Way 

P.O.  Box  5005 

Rochester,  NH  03867-5005 

Contact:  Mr.  John  Ballew 

Phone:  603-337-1742 

Fax:  603-337-1764 

E-Mail:  jballew@ccmailpc.crron.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  March  31,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22: 1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200122-0 

LambdaMetrics,  Inc. 

407  South  Blue  Ridge  Parkway  (78613) 

P.O.  Box  1029 

Cedar  Park,  TX  78630-1029 

Contact:  Mr.  Ben  Bibb 

Phone:  512-219-8218 

Fax:  512-219-8218 

E-Mail:  bennbibb@lambdametrics.com 
FCC  Test  Methods 

Accreditation  Valid  Through:  March  31,1 999 

NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 

1 2/FO  1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  la      Conducted  Emissions,  Power  Lines,  450  KHz 


to  30  MHz 
1 2/FO  lb      Radiated  Emissions 
12/T01       Terminal  Equipment  Network  Protection 

Standards,  FCC  Method  -  47  CFR  Part  68  - 

Analog  and  Digital 
12/T01a      68.302  (Par.  c,d,e,f)  Environmental  simulation; 

68.304  Leakage  current  limit.;  68.306 

Hazardous  voltage  limit.;  68.308  Signal  power 

limit.;  68.310  Longitudinal  balance  limit.; 

68.312  On-hook  impedance  limit.;  68.314 

Billing  protection 
International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22: 1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200124-0 
White  Environmental  Consultants  Inc. 

731  I  Street,  Suite  201 

Anchorage,  AK  99501 

Contact:  Mr.  Sean  Fitzgerald 

Phone:  907-258-8661 

Fax:  907-258-8662 

E-Mail:  Whiteenv@customcpu.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  December  31,  1999 


NVLAP  LAB  CODE  200125-0 
Paradyne  Corporation 

8545  126th  Avenue  N. 

P.O.  Box  2826 

Largo,  FL  33773-2826 

Contact:  Mr.  Tom  Wissman 

Phone:  727-530-2775 

Fax:  727-532-5552 

E-Mail:  twissman@eng.paradyne.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  March  31,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO  1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 


NVLAP  1999  DIRECTORY  -  Page  DUO 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200126-0 
Walker  Bolt  Manufacturing  Co. 

10202  Airline  Drive 
P.O.  Box  38502 
Houston,  TX  77238-8502 
Contact:  Mr.  Tommie  D.  Helms 
Phone:  281-448-4350x230 
Fax:  281-999-1979 


Fasteners  &  Metals 

Accreditation  Valid  Through:  March  31,  1999 
NVLAP 

Code  Designation 
Chemical  Analysis 

Optical  emission  spectrochemical  analysis 
FA/457  ASTME415 
Dimensional  Inspection 

Dimensions  of  ISO  grade  A  and  B  fasteners 

FA/487      DIN  267,  Part  5 

Dimensions  of  ISO  grade  C  fasteners 

FA/488      DIN  267,  Part  5 

Dimensions  of  general  purpose  fasteners  and 

high-volume  machine  assembly  fasteners 

FA/403  ANSI/ASMEB18.18.1M 

FA/486      MIL-STD- 1 20  (W/  Notice  dtd  9  SEP  63) 

Dimensions  of  special  purpose  fasteners  and  fasteners  for 

highly  specialized  engineered  ap 

FA/405  ANSI/ASMEB18.18.3M 

FA/406      ANSI/ASME  B 1 8. 1 8.4M 

FA/493       MIL-STD-120  (W/  Notice  dtd  9SEP  63) 

External  thread  parameters  -  system  21 

FA/379      ANSI/ASME  B1.3M 

FA/380  FED-STD-H28/20 

External  thread  parameters  -  system  22 

FA/381       ANSI/ASME  B1.3M 

FA/382  FED-STD-H28/20 

External  thread  parameters  -  system  23 

FA/385       ANSI/ASME  B1.3M 

FA/386  FED-STD-H28/20 

Internal  thread  parameters  -  system  21 

FA/391       ANSI/ASME  B1.3M 

FA/392  FED-STD-H28/20 

Internal  thread  parameters  -  system  22 

FA/393       ANSI/ASME  B1.3M 

FA/394  FED-STD-H28/20 

Internal  thread  parameters  -  system  23 

FA/397      ANSI/ASME  B1.3M 

FA/398  FED-STD-H28/20 


Mechanical  and  Physical  Testing  and  Inspection 

Axial  tensile  strength  of full-size  threaded  fasteners 

FA/265       ASTMA370Sec.  A3. 2. 1.4 
FA/266       ASTM  F606  Sec.  3.4.1-3.4.3 
FA/267      ASTM  F606M  Sec.  3.4.1-3.4.3 
FA/273       SAE  J429 
Brinell  hardness  of  fasteners 
FA/185       ASTM  A370  Sec.  16 
FA/186      ASTM  E10 
FA/491       ASTM  El 8 
Charpy  impact  (v-notch)  testing 
FA/21 1       ASTM  A370  Sec.  19-28 
FA/212  ASTME23 
Hardness  preparation 
FA/464      ASTM  F606M 
FA/482      ASTM  F606 
Microhardness  of  fasteners 
FA/ 189      ASTM  E3  84 

Proof  load  of full-size  externally  threaded  fasteners 

FA/225       ASTM  A370  Sec.  A3. 2. 1.1 -A3. 2. 1.3 

FA/226      ASTM  F606  Sec.  3.2.1-3.2.3 

FA/228       ISO  898-1  Sec.  8.4 

FA/229       SAE  J429  Sec.  5.3 

FA/467      ASTM  F606M  Sec.  3.2.1-3.2.3 

Proof  load  of  internally  threaded  fasteners  (nuts) 

FA/235       ASTM  A370  Sec.  A3. 5.1 

FA/236      ASTM  F606  Sec.  4.2 

FA/237      ASTM  F606M  Sec.  4.2 

FA/239      ISO  898-2  Sec.  8.1 

FA/241       SAE  J995  Sec.  5.1 

Rockwell  hardness  of  fasteners 

FA/ 196      ASTM  A3 70  Sec.  18 

FA/197      ASTM  El 8 

FA/201  MIL-STD-1312-6 

Tension  testing  of  machined  specimens  from  externally 
threaded  fasteners 

FA/278       ASTM  A370 
FA/279      ASTM  F606 
FA/280      ASTM  F606M 
FA/282      ISO  898-1 
FA/283       SAE  J429 

Total  extension  at  fracture  of  externally  threaded 
fasteners 

FA/285       ASTM  F606 
FA/286       ASTM  F606M 

Vickers  hardness  -  test  forces  from  9.807 to  1176  N (1  to 
120  kgf) 

FA/492      ASTM  E92 

Wedge  tensile  strength  of  full-size  threaded  fasteners 

FA/289      ASTM  A370 
FA/290      ASTM  F606  Sec.  3.5 
FA/291       ASTM  F606M  Sec.  3.5 
FA/294      ISO  898-1  Sec.  8.5 
FA/468       SAE  J429  Sec.  5.5 

Metallography 


NVLAP  1999  DIRECTORY  -  Page  Dill 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Decarburization  and  case  depth  measurement  in 
fasteners 

FA/324       ISO  898-1 

FA/328  SAEJ121 

FA/483       ASTM  A574  Sec.  12 

Macroscopic  examination  of  fasteners  by  etching 

FA/484      ASTM  E3  81 

Nondestructive  Inspection 

Liquid  penetrant  inspection  of  fasteners 

FA/367       ASTM  El 65 

FA/370  MIL-STD-271 

FA/371  MIL-STD-6866 

Magnetic  particle  inspection  of  fasteners 

FA/376  MIL-STD-271 

FA/485       ASTM  El 444 

NVLAP  LAB  CODE  200128-0 
The  Perryman  Company 

213  Vandale  Drive 
Houston,  PA  15342 
Contact:  Ms.  Shirley  J.  Kemper 
Phone:  724-746-9390 
Fax:  724-746-9392 


Fasteners  &  Metals 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 
Chemical  Analysis 

Combustion  analysis  for  carbon,  sulfur,  oxygen, 
nitrogen,  and  hydrogen 
FA/472      ASTM  El 447 
Dimensional  Inspection 

Surface  texture 

FA/554       AMS  4928 

Mechanical  and  Physical  Testing  and  Inspection 

Axial  tensile  strength  of  full-size  threaded  fasteners 

FA/530      ASTM  E8 

Double  shear  of  externally  threaded  fasteners 

FA/257  MIL-STD-1312-13 

Rockwell  hardness  of  fasteners 

FA/ 197       ASTM  El 8 

Metallography 

Determination  of  grain  size  of fasteners 
FA/331       ASTM  El  12 
FA/550       ASTM  E3 

Macroscopic  examination  of  fasteners  by  etching 

FA/551  ASTME3 

Microscopic  examination  of  fasteners  by  etching 

FA/512  ASTME407 
FA/552      ASTM  E3 
FA/553       AMS  2643 


NVLAP  LAB  CODE  200129-0 

AHD 

92723  M-152 

Dowagiac,  MI  49047 

Contact:  Mr.  Edmund  (Ted)  Chaffee 

Phone:  616-424-7014 


FCC  Test  Methods 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  la      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  1  b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

1 2/CIS22    IEC/CISPR  22: 1 993 :  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200130-0 
NASA-Lewis  Research  Center 

21000  Brookpark  Road,  Mail  Stop  6-4 
Cleveland,  OH  44135-3191 
Contact:  Ms.  Priscilla  Mobley 
Phone:  216-433-8333 
Fax:  216-433-8719 

E-Mail:  priscilla.a.mobley@lerc.nasa.gov 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  200131-0 
Environmental  Testing  and  Monitoring  Services, 
Inc. 

2425  Boward  Parkway,  Suite  107 
Virginia  Beach,  VA  23454 
Contact:  Mr.  Scott  J.  Eggleston 
Phone:  757-498-7873 
Fax:  757-498-7896 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  1999  DIRECTORY  -  Page  D112 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  200132-0 
USG  Research-Systems  Evaluation  Laboratory 

700  N.  Highway  45 

Libertyville,  IL  60048-1296 

Contact:  Mr.  Richard  T.  Kaczkowski 

Phone:  847-970-52559 

Fax:  847-362-4871 

E-Mail:  rkaczkowski@isgres.com 

Acoustical  Testing  Services 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

08/P03       ASTM  C423  (ISO  354) 
08/P06       ASTM  E90  (ISO  140,  Part  3) 
08/P33       ASTM  El  111 

08/P34       ASTM  E1414  (AMA-l-II-67)(ISO  140,  Part  9) 
NVLAP  LAB  CODE  200133-0 
Electronics  Testing  Center,  Taiwan 

No.8,  Lane  29,  Wen-Ming  Rd 
Lo-Shan  Tsun,  Kui-shan  Hsiang 
Taoyuan  Hsien  333 
TAIWAN 

Contact:  Mr.  Jing-Jung  Hong 
Phone:  886-03-328-0026  x272 
Fax:  886-03-328-0034 
E-Mail:  hong@etc.org.tw 

FCC  Test  Methods 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
12/F01       FCC  Method  -  47  CFR  Part  15  -  Digital 
Devices 

12/F01a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
12/F01b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22: 1 993 :  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 


NVLAP  LAB  CODE  200134-0 
Marathon  Electric  -  Wausau  Engineering  Lab. 

100  East  Randolph  Street 
P.O.  Box  8003 
Wausau,  WI  54402-8003 
Contact:  Mr.  Gene  Sickler 
Phone:  715-675-3311  x4155 
Fax:  715-675-8043 


Efficiency  of  Electric  Motors 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

24/M01      IEEE  112,  Method  B  

NVLAP  LAB  CODE  200135-0 
AST  Research,  Inc.  EMC  Lab. 

16225  Alton  Parkway 
Irvine,  CA  92618-3618 
Contact:  Mr.  Jozef  Baran 
Phone:  949-727-7654 
Fax:  949-727-8329 


FCC  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/F0 1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO 1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22: 1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200136-0 
Wilson-Garner  Company 

40935  Production  Drive 
Harrison  Township,  MI  48045-3422 
Contact:  Mr.  Timothy  Pinchback 
Phone:  810-466-5800 
Fax:  810-465-4408 


NVLAP  1999  DIRECTORY  -  Page  D113 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Fasteners  &  Metals 

Accreditation  Valid  Through:  December  31,1 999 
NVLAP 

Code  Designation 
Dimensional  Inspection 

Dimensions  of  fasteners  -  flange  screw  heads  and  flange 
nuts 

FA/419  ANSI/ASMEB18.2.3.4M 
FA/420  ANSI/ASMEB18.2.3.9M 
Dimensions  of  fasteners  -  straightness 
FA/423       ANSI/ASMEB  18.2.1 
FA/755  ANSIB18.2.3.1M 

Dimensions  of  special  purpose  fasteners  and  fasteners  for 

highly  specialized  engineered  ap 

FA/405  ANSI/ASMEB18.18.3M 

FA/406  ANSI/ASMEB18.18.4M 

External  thread  parameters  -  system  21 

FA/379  ANSI/ASMEB1.3M 

External  thread  parameters  -  system  22 

FA/381       ANSI/ASMEB  1.3M 

Mechanical  and  Physical  Testing  and  Inspection 

Adhesion  of  metallic  coatings  on  fasteners 
FA/143  ASTMB571 
FA/145  SAEJ207 

Axial  tensile  strength  of full-size  threaded  fasteners 
FA/266       ASTMF606  Sec.  3.4.1-3.4.3 
FA/267      ASTM  F606M  Sec.  3.4. 1  -3.4.3 
FA/271  MIL-STD-1312-8 
FA/273       SAE  J429 
FA/274  SAEJ1216 

Hydrogen  embrittlement  (stress  durability)  of  externally 

threaded  fasteners 

FA/176  MIL-STD-1312-5 

Measurement  of  fastener  coating  thickness  -  dimensional 

change  method 

FA/495  MIL-STD-1312-12 

Measurement  of  fastener  coating  thickness  -  magnetic 
methods 

FA/155  ASTME376 

FA/159  MIL-STD-1312-12 

Proof  load  of  full-size  externally  threaded  fasteners 

FA/226      ASTM  F606  Sec.  3.2.1-3.2.3 

FA/229       SAE  J429  Sec.  5.3 

FA/230       SAE  J1216  Sec.  3.3 

FA/467       ASTM  F606M  Sec.  3.2.1-3.2.3 

Rockwell  hardness  of  fasteners 

FA/197       ASTM  El 8 

FA/201  MIL-STD-1312-6 

Rockwell  superficial  hardness  of  fasteners 

FA/205       ASTM  El 8 

FA/209  MIL-STD-1312-6 

Wedge  tensile  strength  of full-size  threaded  fasteners 

FA/289       ASTM  A370 

FA/290      ASTM  F606  Sec.  3.5 

FA/291       ASTM  F606M  Sec.  3.5 

FA/295  MIL-STD-1312-8 

FA/468       SAE  J429  Sec.  5.5 


FA/469       SAE  J1216  Sec.  3.6 
Nondestructive  Inspection 

Magnetic  particle  inspection  of  fasteners 

FA/485       ASTM  El 444  

NVLAP  LAB  CODE  200137-0 
Philips  Electronics  Industries  (TAIWAN)  Ltd. 

5,  Tze  Chiang  1  Road,  Chungli  Ind.  Park 
P.O.  Box  123,  Chungli 
Chungli,  Taoyuan 
TAIWAN 

Contact:  Mr.  Ronnie  Yang 
Phone:  886-2-454-9862 
Fax:  886-3-454-9887 

E-Mail:  ronnie.yang@rw.ccmail.philips.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

1 2/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200138-0 
Hewlett  Packard,  Product  Test  Lab,  San  Diego 

16399  W.  Bernardo  Drive 
San  Diego,  CA  92127-1899 
Contact:  Mr.  John  Hall 
Phone:  619-655-8236 
Fax:  619-655-5786 
E-Mail:  john_hall@HP.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  March  31,  1999 

NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO  1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  1  a      Conducted  Emissions,  Power  Lines,  450  KHz 
to  30  MHz 


NVLAP  1999  DIRECTORY  -  Page  D114 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


12/F01b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200139-0 

PB  Fasteners 

1700  W.  132nd  Street 
P.O.  Box  1157 
Gardena.CA  90249-0157 
Contact:  Mr.  Verne  Benson 
Phone:  310-323-6222 
Fax: 310-329-4685 


Fasteners  &  Metals 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 
Dimensional  Inspection 

Dimensions  of  fasteners  -  hexagon  and  double  hexagon 

(12  point)  and  spline  sockets 

FA/539      SAE  AS  870 

FA/540  MIL-STD-33787 

External  thread  parameters  -  system  21 

FA/379      ANSI/ASME  BUM 

FA/380  FED-STD-H28/20 

FA/528  MIL-S-7742 

FA/533       SAE  AS  8879 

External  thread  parameters  -  system  22 

FA/381       ANSI/ASME  B1.3M 

FA/382  FED-STD-H28/20 

FA/383  MIL-S-7742 

FA/534      SAE  AS  8879 

External  thread  parameters  -  system  23 

FA/385       ANSI/ASME  B1.3M 

FA/386  FED-STD-H28/20 

FA/388  MIL-S-8879 

FA/535       SAE  AS  8879 

Internal  thread  parameters  -  system  21 

FA/391       ANSI/ASME  B1.3M 

FA/392  FED-STD-H28/20 

FA/529  MIL-S-7742 

FA/536       SAE  AS  8879 

Internal  thread  parameters  -  system  22 

FA/393       ANSI/ASME  B1.3M 

FA/394  FED-STD-H28/20 

FA/395  MIL-S-7742 

FA/537      SAE  AS  8879 

Internal  thread  parameters  -  system  23 

FA/397      ANSI/ASME  B1.3M 

FA/398  FED-STD-H28/20 

FA/399  MIL-S-7742 

FA/538       SAE  AS  8879 


Surface  texture 

FA/439       ANSI/ASME  B46. 1 

Mechanical  and  Physical  Testing  and  Inspection 

Adhesion  of  metallic  coatings  on  fasteners 

FA/532      BMS  10-85M  Sec.  8.2 

Axial  tensile  strength  of full-size  threaded  fasteners 

FA/271  MIL-STD-1312-8 

Double  shear  of  externally  threaded  fasteners 

FA/257  MIL-STD-1312-13 

Fatigue  of  full-size  threaded  fasteners 

FA/ 183  MIL-STD-1312-11 

Hydrogen  embrittlement  (stress  durability)  of  externally 

threaded  fasteners 

FA/176  MIL-STD-1312-5 

Magnetic  permeability 

FA/215  MIL-I-17214 

Measurement  of  fastener  coating  thickness  -  eddy-current 
method 

FA/150      FED  TM  STD  NO.  151  Method  520.1 
FA/152      MIL-STD-13 12-12 
Microhardness  of  fasteners 
FA/189  ASTME384 
FA/ 193       MIL-STD-13 12-6 
Permanent  set  test  of  self-locking  nuts 
FA/109  MIL-N-25027 

Recess  strength  test  in  both  the  installation  and  removal 
directions 

FA/476      MIL-STD-13 12-25 

Reusability  test  of  self-locking  internally  threaded 

fasteners 

FA/522      MIL-STD-13 12-31 

Rockwell  hardness  of  fasteners 

FA/201       MIL-STD-13 12-6 

Rockwell  superficial  hardness  of  fasteners 

FA/209      MIL-STD-13 12-6 

Salt  spray  testing  of  fasteners 

FA/166  ASTMB117 

FA/ 168      MIL-STD-13 12-1 

Single  shear  of  externally  threaded  fasteners 

FA/256      MIL-STD-13 12-20 

Stress  rupture  of  fasteners 

FA/262      MIL-STD-13 12-10 

Tension  testing  of  machined  specimens  from  externally 

threaded  fasteners 

FA/475       ASTM  E8 

FA/526  MIL-STD-1312-8 

Test  for  embrittlement  of  metallic  coated  externally 

threaded  fasteners 

FA/525  MIL-STD-1312-5 

Torque-out  test 

FA/523       MIL-STD-13 12-31 

Wedge  tensile  strength  of full-size  threaded  fasteners 

FA/295  MIL-STD-1312-8 

Wrench  torque  test  of  externally  wrenched  nuts  of  spline 
and  hexagon  and  double  hexagon  (1 
FA/524      MIL-STD-13 12-31 


NVLAP  1999  DIRECTORY  -  Page  D115 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Yield  strength  of  full-size  externally  threaded  fasteners 

FA/303  MIL-STD-1312-8 

Metallography 

Decarburization  and  case  depth  measurement  in 
fasteners 

FA/521  ASTME384 
Determination  of  grain  size  of fasteners 
FA/331  ASTME112 

Macroscopic  examination  of  fasteners  by  etching 

FA/511  ASTME340 

Microscopic  examination  of  fasteners  by  etching 
FA/512  ASTME407 
Nondestructive  Inspection 

Liquid  penetrant  inspection  of  fasteners 
FA/527      ASTM  E1417 
Magnetic  particle  inspection  of  fasteners 
FA/485       ASTM  E1444 

NVLAP  LAB  CODE  200140-0 
TAO/TA2  EMC  Laboratory 

255,  JEN-HO  Road  Sec  2,  Tachi 

Taoyuan 

TAIWAN 

Contact:  Mr.  Steve  Wang 

Phone:  886-3-390-0000 

Fax:  886-3-389-4346 

E-Mail:  Steve.Wang@digital.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 


NVLAP  LAB  CODE  200141-0 

MAC  Fasteners,  Inc. 

1544  S.  Main  Street 

Ottawa,  KS  66067 

Contact:  Mr.  Donald  C.  Krenkel 

Phone:  785-242-8812 

Fax:  785-242-4616 


Fasteners  &  Metals 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 
Dimensional  Inspection 

External  thread  parameters  -  system  21 

FA/380  FED-STD-H28/20 

External  thread  parameters  -  system  22 

FA/382  FED-STD-H28/20 

Mechanical  and  Physical  Testing  and  Inspection 

Adhesion  of  metallic  coatings  on  fasteners 

FA/541       QQ-P-416  Sec.  4.6.2 

Axial  tensile  strength  of full-size  threaded  fasteners 

FA/799      NASM  1312-8 

Double  shear  of  externally  threaded  fasteners 

FA/880      NASM  1312-13 

Intergranular  corrosion  susceptibility  in  a  listen  tic 

stainless  steel  fasteners  -  nitric  aci 

FA/ 173       ASTM  A262  Sec.  15-21,  Practice  C 

Measurement  of  fastener  coating  thickness  -  dimensional 

change  method 

FA/874      NASM  1312-12 

Measurement  of  fastener  coating  thickness  - 

microscopical  method 

FA/873       NASM  1312-12 

Microhardness  of  fasteners 

FA/877      NASM  1312-6 

Recess  strength  test  in  both  the  installation  and  removal 
directions 

FA/886      NASM  1312-25 

Rockwell  hardness  of  fasteners 

FA/878      NASM  1312-6 

Rockwell  superficial  hardness  of  fasteners 

FB/1004     NASM  1312-6 

Metallography 

Decarburization  and  case  depth  measurement  in 
fasteners 

FA/521  ASTME384 
Determination  of  grain  size  of  fasteners 
FA/331       ASTM  El  12 

Macroscopic  examination  of  fasteners  by  etching 
FA/5 1 1       ASTM  E340 

Microscopic  examination  of  fasteners  by  etching 

FA/512  ASTME407 

Nondestructive  Inspection 


NVLAP  1999  DIRECTORY  -  Page  D116 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Liquid  penetrant  inspection  of fasteners 
FA/371  MIL-STD-6866 
Magnetic  particle  inspection  of  fasteners 
FA/485  ASTME1444 

NVLAP  LAB  CODE  200142-0 
Lockheed  Martin  Control  Systems  EMI 
Laboratory 

600  Main  Street 

Johnson  City,  NY  13790-1888 

Contact:  Mr.  Paul  Heiland 

Phone:  607-770-3771 

Fax:  607-770-2954 

E-Mail:  paul.h.heiland.jr@lmco.co 

MIL-STD-462  Test  Methods 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Conducted  Emissions: 

1 2/AO 1       MIL-STD-462  Method  CEO  1 

12/A06       MIL-STD-462  Method  CE03 

1 2/A 1 2       MIL-STD-462  Method  CE07 

Conducted  Susceptibility: 

1 2/BO 1       MIL-STD-462  Method  CS0 1 

12/B02       MIL-STD-462  Method  CS02 

1 2/B05       MIL-STD-462  Method  CS06 

Radiated  Emissions: 

1 2/DO 1       MIL-STD-462  Method  RE0 1 

1 2/D02       MIL-STD-462  Method  RE02 

Radiated  Susceptibility: 

1 2/E02       MIL-STD-462  Method  RS02 

1 2/E04       MIL-STD-462  Method  RS03  employing 

RADHAZ  procedures  for  high  level  testing 
(Consult  laboratory  for  field  strengths 
available) 

NVLAP  LAB  CODE  200143-0 
Ivaco  Rolling  Mills,  Chemistry  Laboratory 

Highway  17,  P.O.  Box  322 
L'Orignal  Ontario  K0B  1K0 
CANADA 

Contact:  Mr.  William  V.  Berry 
Phone:  613-675-4671  x237 
Fax:  613-675-2463 
E-Mail:  wberry@ivacorm.com 

Fasteners  &  Metals 

Accreditation  Valid  Through:  March  31,  1999 
NVLAP 

Code  Designation 
Chemical  Analysis 

Combustion  analysis  for  carbon,  sulfur,  oxygen, 

nitrogen,  and  hydrogen 

FA/455  ASTME1019 

Optical  emission  spectrochemical  analysis 

FA/457  ASTME415 


NVLAP  LAB  CODE  200144-0 
Dexter  Fastener  Technologies,  Inc. 

21 10  Bishop  Circle  E. 

Dexter,  MI  48130 

Contact:  Mr.  Ken  Summersett 

Phone:  734-426-5200 

Fax:  734-425-5870 

E-Mail:  dextech@midspring.com 

Fasteners  &  Metals 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 
Chemical  Analysis 

Optical  emission  spectrochemical  analysis 
FA/457  ASTME415 
Dimensional  Inspection 

Dimensions  of  ISO  grade  A  and  B  fasteners 

FA/407       ISO  3269 

FA/589  JISB1071 

FA/590  JISB1091 

Dimensions  of  fasteners  -  straightness 

FA/423       ANSI/ASME  B 1 8.2. 1 

Dimensions  of  general  purpose  fasteners  and 

high-volume  machine  assembly  fasteners 

FA/404      ANSI/ASME  B 1 8. 1 8.2M 

Dimensions  of  special  purpose  fasteners  and  fasteners  for 

highly  specialized  engineered  ap 

FA/406      ANSI/ASME  B18.18.4M 

External  thread  parameters  -  ISO 

FA/390      ISO  1502 

External  thread  parameters  -  system  21 

FA/379      ANSI/ASME  B1.3M 

FA/583  JISB0251 

FA/584      JIS  B0252 

External  thread  parameters  -  system  22 

FA/381       ANSI/ASME  B1.3M 

External  thread  parameters  -  system  23 

FA/385       ANSI/ASME  B1.3M 

Mechanical  and  Physical  Testing  and  Inspection 

Axial  tensile  strength  of full-size  threaded  fasteners 

FA/266      ASTM  F606  Sec.  3.4.1-3.4.3 

FA/270      ISO  898-1  Sec.  8.2 

FA/273       SAE  J429 

FA/574      JIS  B1051  Sec.  4.2.2 

Fatigue  of  full-size  threaded  fasteners 

FA/182       ISO  3800-1 

FA/183  MIL-STD-1312-11 

FA/570      JIS  B 1081 

Hardness  preparation 

FA/482      ASTM  F606 

Head  soundness  testing 

FA/614      ISO  898-1  Sec.  8.7 

FA/615       JIS  B 1051  Sec.  4.2.6 


NVLAP  1999  DIRECTORY  -  Page  D117 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Measurement  of fastener  coating  thickness  -  coulometric 
method 

FA/567       ASTM  B504 

Measurement  of  fastener  coating  thickness  - 

microscopical  method 

FA/160  ASTMB487 

Microhardness  of  fasteners 

FA/189  ASTME384 

FA/191       ISO  6507-2 

Proof  load  of  full-size  externally  threaded  fasteners 

FA/226       ASTM  F606  Sec.  3.2.1-3.2.3 

FA/228       ISO  898-1  Sec.  8.4 

FA/229       SAE  J429  Sec.  5.3 

FA/573       JISB 1051  Sec.  4.2.4 

Rockwell  hardness  of  fasteners 

FA/ 197       ASTM  El 8 

FA/200       ISO  6508 

FA/572       JIS  Z2245 

FA/616       JIS  B1051  Sec.  4.3 

FA/617       ISO  898-1  Sec.  8.9 

Rockwell  superficial  hardness  of  fasteners 

FA/205       ASTM  El 8 

Salt  spray  testing  of  fasteners 

FA/166       ASTM  Bl  17 

FA/568       ISO  9227 

FA/569  JISZ2371 

Tension  testing  of  machined  specimens  from  externally 
threaded  fasteners 

FA/279       ASTM  F606  Sec.  3.6 
FA/282       ISO  898-1 
FA/283       SAE  J429 
FA/580       ISO  6892 
FA/581       JIS  B 1051  Sec.  4.2 
FA/582  JISZ2241 

Torque-tension  of  full-size  threaded  fasteners 
FA/576       JISB  1084 

Total  extension  at  fracture  of  externally  threaded 
fasteners 

FA/285       ASTM  F606  Sec.  3.7 

Vickers  hardness  -  test  forces  from  9.807  to  1176  N  (1  to 
120  kgf) 

FA/571  JISZ2244 

Wedge  tensile  strength  of full-size  threaded  fasteners 

FA/290      ASTM  F606  Sec.  3.5 
FA/294       ISO  898-1  Sec.  8.5 
FA/468       SAE  J429  Sec.  5.5 
FA/575       JIS  B1051  Sec.  4.2.3 

Yield  strength  of  full-size  externally  threaded  fasteners 

FA/298       ASTM  F606  Sec.  3.2.4 
Metallography 

Decarburization  and  case  depth  measurement  in 
fasteners 

FA/323       ASTM  El 077 
Determination  of  grain  size  of  fasteners 
FA/331       ASTM  El  12 

Macroscopic  examination  of  fasteners  by  etching 

FA/511  ASTME340 


Microscopic  examination  of  fasteners  by  etching 

FA/512  ASTME407 

Surface  discontinuities  of  externally  threaded  fasteners 

FA/357       ASTM  F788/788M 
FA/359       ISO  6157-1 

NVLAP  LAB  CODE  200145-0 
Neutron  Engineering  Inc. 

1F1.  No.  20,  Alley  50,  Lane  119 

Dong  Hwu  Road,  P.O.  Box  6-158  Nei  Hwu 

Taipei 

TAIWAN 

Contact:  Mr.  George  Yao 

Phone:  886-2-26336872 

Fax:  886-2-26334578 

E-Mail:  neutronl@mslO.hinet.net 

FCC  Test  Methods 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AU ST  EL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200147-0 
Electro  Magnetic  Test,  Inc. 

1547  Plymouth  Street 
Mountain  View,  CA  94043 
Contact:  Mr.  Jay  Gandhi 
Phone:  650-965-4000 
Fax:  650-965-3000 


FCC  Test  Methods 

Accreditation  Valid  Through:  March  31,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/F01        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  la      Conducted  Emissions,  Power  Lines,  450  KHz 
to  30  MHz 


NVLAP  1999  DIRECTORY  -  Page  D118 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


12/F01b      Radiated  Emissions 

12/T01       Terminal  Equipment  Network  Protection 

Standards,  FCC  Method  -  47  CFR  Part  68  - 

Analog  and  Digital 
12/T01a     68.302  (Par.  c,d,e,f)  Environmental  simulation; 

68.304  Leakage  current  limit.;  68.306 

Hazardous  voltage  limit.;  68.308  Signal  power 

limit.;  68.310  Longitudinal  balance  limit.; 

68.312  On-hook  impedance  limit.;  68.314 

Billing  protection 
12/T01b     68.316  Hearing  Aid  Compatibility:  technical 

standards 

12/TOlc      68.302  Environmental  simulation  (Par.  a,b) 
International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200148-0 
BarTech  Inc.  -  Chemical  Laboratory 

1001  Main  Street,  Gate  #3 

Johnstown,  PA  15909 

Contact:  Mr.  Alan  K.  O'Donnell 

Phone:  814-533-7333 

Fax:  814-533-7319 

E-Mail:  alanod@porodigy.net 

Fasteners  &  Metals 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 
Ch  em  ical  A  n  alysis 

Combustion  analysis  for  carbon,  sulfur,  oxygen, 

nitrogen,  and  hydrogen 

FA/455  ASTME1019 

Optical  emission  spectro chemical  analysis 

FA/457      ASTM  E415 

Solution  chemical  analysis 

FA/448      ASTM  E350 

FA/531  ASTME663  

NVLAP  LAB  CODE  200150-0 
Indiana  Automotive  Fasteners,  Inc. 

1300  West  Anderson  Boulevard 
Greenfield,  IN  46140-2777 
Contact:  Mr.  Pete  Murray 
Phone:  317-467-0100 
Fax:  317-467-0400 


Dimensions  of  general  purpose  fasteners  and 
high-volume  machine  assembly  fasteners 
FA/607  JISB1071 
FA/675  JISB1012 

Mechanical  and  Physical  Testing  and  Inspection 

Adhesion  of  metallic  coatings  on  fasteners 
FA/595       JIS  H8504 

Axial  tensile  strength  of full-size  threaded  fasteners 

FA/267      ASTM  F606M  Sec.  3.4.1-3.4.3 

FA/270      ISO  898-1  Sec.  8.2 

FA/273       SAE  J429 

FA/574      JIS  B1051  Sec.  4.2.2 

FA/687       ISO  6892 

Hardness  preparation 

FA/464      ASTM  F606M 

Measurement  of  fastener  coating  thickness  -  eddy-current 
method 

FA/618  JISH8501 

Measurement  of  fastener  coating  thickness  -  weight  of 
coating 

FA/619  JISH8501 
Rockwell  hardness  of  fasteners 

FA/197      ASTM  El 8 
FA/200      ISO  6508 
FA/572      JIS  Z2245 
FA/616      JIS  B 1051  Sec.  4.3 
FA/617       ISO  898-1  Sec.  8.9 
FB/1011  P&WE-OSuppC 
Salt  spray  testing  of  fasteners 
FA/166      ASTM  Bl  17 
FA/598      JIS  H8502 

Vickers  hardness  -  test  forces  from  9.807  to  1 1 76  N  (1  to 
120  kgf) 

FA/492       ASTM  E92 
FA/571  JISZ2244 
FA/643       JIS  B1051  Sec.  4.2.5 
FA/658       ISO  6507-1 

Wedge  tensile  strength  of full-size  threaded  fasteners 

FA/291       ASTM  F606M  Sec.  3.5 
FA/294      ISO  898-1  Sec.  8.5 
FA/575       JIS  B 1051  Sec.  4.2.3 
FA/685       JIS  D4604  Sec.  7.7(1) 
FA/688       ISO  6892 

Metallography 

Decarburization  and  case  depth  measurement  in 
fasteners 

FA/324  ISO  898-1 
FA/329  SAEJ419 
FA/645  JIS  B 1051 
FA/656      ASTM  F606M 


Fasteners  &  Metals 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 
Dimensional  Inspection 


NVLAP  1999  DIRECTORY  -  Page  D119 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  200151-0 

Cosmos  Corporation 

319  Akeno,  Obata-cho 
Watarai-gun  Mie  519-0501 
JAPAN 

Contact:  Mr.  Kay  Hamaguchi 
Phone:  81-596-37-0190 
Fax:  81-596-37-3609 
E-Mail:  cosmos@mint.or.jp 

FCC  Test  Methods 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22     IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200152-0 

inFocus  Systems,  Inc., 

27700B  SE  Parkway  Avenue 

Wilsonville,  OR  97070-9215 

Contact:  Mr.  Don  Rhodes 

Phone:  503-685-8588 

Fax:  503-685-8531 

E-Mail:  don.rhode@infocus.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO  1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  la      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

1 2/CIS22    IEC/CISPR  22: 1 993 :  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 


equipment 

NVLAP  LAB  CODE  200153-0 
MacLean  Fasteners  -  QC  Laboratory 

1000  Allanson  Road 
Mundelein,  IL  60060 
Contact:  Ms.  Charlotte  Kotowski 
Phone:  847-566-0010  x253 
Fax:  847-949-0285 


Fasteners  &  Metals 

Accreditation  Valid  Through:  June  30,  1999 

NVLAP 

Code  Designation 

Dimensional  Inspection 

Dimensions  of  ISO  grade  A  and  B  fasteners 
FA/408       ISO  4759-1 
Dimensions  of  ISO  grade  C  fasteners 
FA/410      ISO  4759-1 

Dimensions  of  fasteners  -  bearing  surface  squareness 

FA/746      ASME/ANSIB1 8.2.2 

FA/950      ANSI/ASME  B 1 8.2.4.2M 

Dimensions  of  fasteners  -  flange  screw  heads  and  flange 

nuts 

FA/422       ANSI/ASME  B18.16.3M 

FA/949       ANSI/ASME  B18. 2.2 

Dimensions  of  fasteners  -  gaging  for  slotted  nuts 

FA/4 1 7       ANSI/ASME  B 1 8.2.2 

FA/4 1 8       ANSI/ASME  B 1 8.2.4.3M 

Dimensions  of  fasteners  -  hexagon  and  double  hexagon 

(12  point)  and  spline  sockets 

FA/843       ASME/ANSI  B 1 8.2.2 

FA/945       ANSI  B  18.2.4. 1M 

Internal  thread  parameters  -  ISO 

FA/402       ISO  1502 

FA/948       ANSI/ASME  B 1 . 1 6M 

Internal  thread  parameters  -  system  21 

FA/942      ANSI/ASME  B  1.2 

FA/946       ANSI/ASME  B1.16M 

Internal  thread  parameters  -  system  22 

FA/943       ANSI/ASME  B  1.2 

FA/947      ANSI/ASME  B1.16M 

Mechanical  and  Physical  Testing  and  Inspection 

Cone  proof  load  of  internally  threaded  fasteners  (nuts) 

FA/22 1       ASTM  F606M  Sec.  4.3 
FA/95 1       SAE  J995 
Hardness  preparation 
FA/464       ASTM  F606M 

Measurement  of  fastener  coating  thickness  -  magnetic 
methods 

FA/155  ASTME376 
Prevailing  torque 
FA/217       IFI- 100/1 07 
FA/218       ISO  2320 

Proof  load  of full-size  externally  threaded  fasteners 

FA/229       SAE  J429  Sec.  5.3 


NVLAP  1999  DIRECTORY  -  Page  D120 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


FA/230      SAE  J1216  Sec.  3.3 

FA/467      ASTM  F606M  Sec.  3.2.1-3.2.3 

Proof  load  of  internally  threaded  fasteners  (nuts) 

FA/237      ASTM  F606M  Sec.  4.2 

FA/241       SAE  J995  Sec.  5.1 

FA/242      SAE  J1216  Sec  4.2 

Rockwell  hardness  of  fasteners 

FA/197      ASTM  El  8 

FA/200      ISO  6508 

FA/202  SAEJ417 

Rockwell  superficial  hardness  of  fasteners 

FA/205       ASTM  El 8 

FA/208       ISO  1024 

FA/210       SAE  J4 1 7 

Torque-tension  of full-size  threaded  fasteners 
FA/306  IFI-101 
FA/308       SAE  J 174 
FA/944      ISO  2320 

Metallography 

Decarburization  and  case  depth  measurement  in 
fasteners 

FA/323       ASTM  El 077 
FA/329       SAE  J4 1 9 
FA/330      SAE  J423 

Microscopic  examination  of  fasteners  by  etching 
FA/512  ASTME407 
FA/552      ASTM  E3 

Surface  discontinuities  of  internally  threaded  fasteners 
FA/364      ASTM  F812M 

FA/703       SAE  J 122   

NVLAP  LAB  CODE  200155-0 
Thomas  Lighting  Accent  Division  Photometric 
Laboratory 

6430  East  Slauson  Avenue 
Los  Angeles,  CA  90040 
Contact:  Mr.  William  Mercado 
Phone:  213-726-1800x245 
Fax:  213-724-1310 


Energy  Efficient  Lighting  Products 

Accreditation  Valid  Through:  March  31,  1999 
NVLAP 

Code  Designation 

Luminaires  (Lighting  Fixtures) 
22/F04  IESLM-41 
22/F05       IES  LM-46 


NVLAP  LAB  CODE  200157-0 
Seiko  Epson  Corporation 

80  Harashinden  Hirooka 
Shiojiri-City  Nagano  399-0785 
JAPAN 

Contact:  Mr.  Atsushi  Shinozaki 
Phone:  81  263-52-5094 
Fax:  81  263-54-5806 

E-Mail:  atsushi.shinozaki@exc.epson.co.jp 

FCC  Test  Methods 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/F0 1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO 1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
12/F01b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200158-0 
San  Shing  Hardware  Works  Co.,  Ltd.  Test 
Laboratory 

No.  851  Chung  Shan  Rd.  Nan-Shing  Kui-Jen 

Tainan 

TAIWAN 

Contact:  Mr.  Jackson  Chen 
Phone:  886-6-230661  1  x311 
Fax:  886-6-2306000 


Fasteners  &  Metals 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 
Dimensional  Inspection 

Dimensions  of fasteners  -  flange  screw  heads  and  flange 
nuts 

FA/566      IFID21p.  D21 

Dimensions  of fasteners  -  gaging  for  slotted  nuts 

FA/417  ANSI/ASMEB18.2.2 

Internal  thread  parameters  -  ISO 

FA/953       ANSI/ASMEB  18.2.2 

Internal  thread  parameters  -  system  21 

FA/391       ANSI/ASMEB  1.3M 

FA/942      ANSI/ASMEB  1.2 


NVLAP  1999  DIRECTORY  -  Page  D121 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Internal  thread  parameters  -  system  22 
FA/393       ANSI/ASME  B 1 .3M 
FA/943       ANSI/ASME  B 1 .2 

Mechanical  and  Physical  Testing  and  Inspection 

Clamp  load  test 
FA/558       ISO  2320 
FA/559      DIN  267,  Part  15 
FA/560  IFI-100/107 

Cone  proof  load  of  internally  threaded  fasteners  (nuts) 
FA/220      ASTM  F606  Sec.  4.3 
FA/221       ASTM  F606M  Sec.  4.3 
Measurement  of  fastener  coating  thickness  -  X-ray 
methods 

FA/556       ASTM  B568 

Measurement  of  fastener  coating  thickness  -  weight  of 
coating 

FA/ 164      ASTM  A90 

Microhardness  of  fasteners 

FA/189  ASTME384 

Prevailing  torque 

FA/217  IFI-100/107 

FA/218       ISO  2320 

FA/557      DIN  267,  Part  15 

Proof  load  of  internally  threaded  fasteners  (nuts) 

FA/236       ASTM  F606  Sec.  4.2 

FA/237      ASTM  F606M  Sec.  4.2 

FA/239       ISO  898-2  Sec.  8.1 

FA/241       SAE  J995  Sec.  5.1 

Rockwell  hardness  of  fasteners 

FA/197      ASTM  El 8 

Rockwell  superficial  hardness  of  fasteners 

FA/205       ASTM  El 8 

Salt  spray  testing  of  fasteners 

FA/166      ASTM  Bl  17 

Torque-tension  of full-size  threaded  fasteners 

FA/306  IFI-101 

Total  extension  at  fracture  of  externally  threaded 
fasteners 

FA/285       ASTM  F606  Sec.  3.7 

FA/286      ASTM  F606M  Sec.  3.7 

Vickers  hardness  -  test  forces  from  9.807  to  1176  N  (1  to 

120  kgf) 

FA/492       ASTM  E92 
Metallography 

Decarburization  and  case  depth  measurement  in 
fasteners 

FA/323       ASTM  El 077 
FA/561  ASTME3 
FA/562      ASTM  G79 

Surface  discontinuities  of  internally  threaded  fasteners 

FA/865  ASTMF812/F812M 


NVLAP  LAB  CODE  200161-0 
Robbins  Manufacturing  Co.,  Inc. 

1200  Airport  Road 
P.O.  Box  704/750 
Fall  River,  MA  02722 
Contact:  Mr.  Robert  J.  Laborio 
Phone:  508-675-2555 
Fax:  508-677-0494 


Fasteners  &  Metals 

Accreditation  Valid  Through:  March  31,  1999 
NVLAP 

Code  Designation 
Dimensional  Inspection 

Dimensions  of  general  purpose  fasteners  and 

high-volume  machine  assembly  fasteners 

FA/494      ANSI  B 18. 2.1 

External  thread  parameters  -  system  21 

FA/379       ANSI/ASME  B1.3M 

External  thread  parameters  -  system  22 

FA/381       ANSI/ASME  B1.3M 

Internal  thread  parameters  -  system  21 

FA/391       ANSI/ASME  B1.3M 

Internal  thread  parameters  -  system  22 

FA/393       ANSI/ASME  B1.3M 

Mechanical  and  Physical  Testing  and  Inspection 

Axial  tensile  strength  of full-size  threaded  fasteners 

FA/266      ASTM  F606  Sec.  3.4. 1-3.4.3 

Magnetic  permeability 

FA/2 1 4       ASTM  A342  Test  Method  3 

Proof  load  of full-size  externally  threaded  fasteners 

FA/226      ASTM  F606  Sec.  3.2.1-3.2.3 

Proof  load  of  internally  threaded  fasteners  (nuts) 

FA/236      ASTM  F606  Sec.  4.2 

Rockwell  hardness  of  fasteners 

FA/ 197      ASTM  El 8 

Salt  spray  testing  of  fasteners 

FA/166       ASTM  Bl  17 

Tension  testing  of  machined  specimens  from  externally 
threaded  fasteners 

FA/279       ASTM  F606 

Total  extension  at  fracture  of  externally  threaded 
fasteners 

FA/285       ASTM  F606 

Wedge  tensile  strength  of full-size  threaded  fasteners 

FA/290      ASTM  F606  Sec.  3.5 

Yield  strength  of full-size  externally  threaded  fasteners 

FA/298       ASTM  F606  Sec.  3.2.4 

Metallography 

Decarburization  and  case  depth  measurement  in 
fasteners 

FA/483       ASTM  A574  Sec.  12 
Nondestructive  Inspection 


NVLAP  1999  DIRECTORY  -  Page  D122 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Liquid  penetrant  inspection  of fasteners 
FA/367  ASTME165 
FA/370  MIL-STD-271 

NVLAP  LAB  CODE  200162-0 
United  States  Technologies,  Inc. 

3505  Francis  Circle 
Alpharetta,  GA  30201-2989 
Contact:  Mr.  Tim  Johnson 
Phone:  770-740-0717 
Fax:  770-740-1508 

E-Mail:  tjohnson.UStech@mindspring.com 
URL:  http://www.ustech-lab.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  la      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
12/F01b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22: 1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200163-0 
Ricoh  Company,  Ltd.  Ohmori  EMC  Center 

3-6,  Naka-magome  1-Chome  Ohta-ku 

Tokyo  143-8555 

JAPAN 

Contact:  Mr.  Akio  Niki 

Phone:  81-3-3776-6281 

Fax: 81-3-3777-8317 

E-Mail:  akio.niki@nts.ricoh.co.jp 

FCC  Test  Methods 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 
12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
12/F01       FCC  Method  -  47  CFR  Part  15  -  Digital 
Devices 

12/F01a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 


International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

1 2/CIS22    IEC/CISPR  22: 1 993 :  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200164-0 
SPS  Technologies;  Aerospace  Fastener  Group 

Highland  Avenue 
Jenkintown,  PA  19046 
Contact:  Mr.  Eric  G.  Hakun 
Phone:  215-572-3716 
Fax:  215-572-3725 


Fasteners  &  Metals 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 
Chemical  Analysis 

Combustion  analysis  for  carbon,  sulfur,  oxygen, 
nitrogen,  and  hydrogen 
FA/625       SPS  Q.C. 0.1.2.5. 134 
Dimensional  Inspection 

Dimensions  of  fasteners  -  bearing  surface  squareness 
FA/633  MIL-N-25027 

Dimensions  of fasteners  -  gaging  for  slotted  nuts 
FA/632  MIL-N-25027 

Dimensions  of  fasteners  -  hexagon  and  double  hexagon 

(12  point)  and  spline  sockets 

FA/411       ANSI/ASME  B18.3 

FA/540  MIL-STD-33787 

FA/634  MIL-STD-21132 

FA/635       SAE  AS  870 

Dimensions  of  fasteners  -  straightness 

FA/423       ANSI/ASME  B 18. 2.1 

Dimensions  of  general  purpose  fasteners  and 

high-volume  machine  assembly  fasteners 

FA/403       ANSI/ASME  B  18.1 8. 1M 

Dimensions  of  special  purpose  fasteners  and  fasteners  for 

highly  specialized  engineered  ap 

FA/405       ANSI/ASME  B  18.1 8. 3M 

FA/406      ANSI/ASME  B 1 8. 1 8.4M 

External  thread  parameters  -  system  21 

FA/379      ANSI/ASME  B1.3M 

FA/380  FED-STD-H28/20 

FA/628  MIL-S-8879 

External  thread  parameters  -  system  22 

FA/381       ANSI/ASME  B1.3M 

FA/382  FED-STD-H28/20 

FA/384  MIL-S-8879 

External  thread  parameters  -  system  23 

FA/385       ANSI/ASME  B1.3M 

FA/386  FED-STD-H28/20 

FA/388  MIL-S-8879 


NVLAP  1999  DIRECTORY  -  Page  D123 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Internal  thread  parameters  -  system  21 

FA/39 1       ANSI/ASME  B 1 .3M 
FA/392  FED-STD-H28/20 
FA/629  MIL-S-8879 
Internal  thread  parameters  -  system  22 
FA/393       ANSI/ASME  BUM 
FA/394  FED-STD-H28/20 
FA/396  MIL-S-8879 
Internal  thread  parameters  -  system  23 
FA/397       ANSI/ASME  B1.3M 
FA/398  FED-STD-H28/20 
FA/400  MIL-S-8879 
Surface  texture 

FA/439       ANSI/ASME  B46.1 

Mechanical  and  Physical  Testing  and  Inspection 

Adhesion  of  metallic  coatings  on  fasteners 
FA/143  ASTMB571 

Axial  tensile  strength  of  full-size  threaded  fasteners 

FA/265       ASTM  A370  Sec.  A3. 2. 1 .4 
FA/266       ASTM  F606  Sec.  3.4.1-3.4.3 
FA/271  MIL-STD-1312-8 
Charpy  impact  (v-notch)  testing 
FA/212  ASTME23 

Compression  load  of  compressible-washer-type  direct 
tension  indicators 

FA/639  SPS-J-610 

Cone  proof  load  of  internally  threaded  fasteners  (nuts) 

FA/220      ASTM  F606  Sec.  4.3 

Copper  sulfate  test  -  test  for  free  iron  on  the  surface  of 

corrosion  resistant  fasteners 

FA/636  MIL-STD-753 

Double  shear  of  externally  threaded  fasteners 

FA/257  MIL-STD-1312-13 

Elevated  temperature  testing  capability 

FA/505  MIL-STD-1312-18 

FA/546  ASTME21 

FA/627  MIL-STD1312-28 

Fatigue  of full-size  threaded  fasteners 

FA/183  MIL-STD-1312-11 

FA/184  NAS1069 

Flareability  test  of  clinch  and  shank  nuts 

FA/626  SPSQ.C.O.I.2.5.134 

Hardness  preparation 

FA/482       ASTM  F606 

Humidity  testing  of  fasteners 

FA/169      MIL-STD-753  Test  Method  101 

FA/170  QQ-P-35 

FA/473  MIL-STD-1312-3 

Hydrogen  embrittlement  (stress  durability)  of  externally 

threaded  fasteners 

FA/176  MIL-STD-1312-5 

Hydrogen  embrittlement  (stress  durability)  of  internally 

threaded  fasteners 

FA/178  MIL-STD-1312-14 

Intergranular  corrosion  susceptibility  of  austentic 

stainles  steel  fasteners  -  oxalic  acid 

FA/1 74      ASTM  A262  Sec.  3-7,  Practice  A 


Magnetic  permeability 

FA/214      ASTM  A342  Test  Method  3 

Measurement  of  fastener  coating  thickness  -  X-ray 

methods 

FA/556      ASTM  B568 

Measurement  of  fastener  coating  thickness  -  dimensional 

change  method 

FA/495  MIL-STD-1312-12 

Measurement  of  fastener  coating  thickness  -  eddy-current 
method 

FA/148  ASTMB244 
FA/152  MIL-STD-1312-12 

Measurement  of  fastener  coating  thickness  -  magnetic 
methods 

FA/153  ASTMB499 
FA/159  MIL-STD-1312-12 
Measurement  of  fastener  coating  thickness  - 
microscopical  method 

FA/160  ASTMB487 

FA/ 163  MIL-STD-1312-12 

Measurement  of  fastener  coating  thickness  -  weight  of 
coating 

FA/165  MIL-STD-1312-12 
Microhardness  of  fasteners 
FA/189  ASTME384 
FA/193  MIL-STD-1312-6 
Permanent  set  test  of  self-locking  nuts 
FA/109  MIL-N-25027 
Prevailing  torque 
FA/630  MIL-N-25027 

Proof  load  of full-size  externally  threaded  fasteners 

FA/226      ASTM  F606  Sec.  3.2.1-3.2.3 

Proof  load  of  internally  threaded  fasteners  (nuts) 

FA/236      ASTM  F606  Sec.  4.2 

Recess  strength  test  in  both  the  installation  and  removal 
directions 

FA/476  MIL-STD-1312-25 

Reusability  test  of  self-locking  internally  threaded 

fasteners 

FA/124  MIL-N-25027 

FA/522  MIL-STD-1312-31 

Rockwell  hardness  of  fasteners 

FA/197      ASTM  El 8 

FA/201  MIL-STD-1312-6 

Rockwell  superficial  hardness  of  fasteners 

FA/205       ASTM  El 8 

FA/209  MIL-STD-1312-6 

Salt  spray  testing  of  fasteners 

FA/166       ASTM  Bl  17 

FA/168  MIL-STD-1312-1 

Single  shear  of  externally  threaded  fasteners 

FA/255       ASTM  F606 

FA/256  MIL-STD-1312-20 

Stress  corrosion  of  fasteners 

FA/172  MIL-STD-1312-9 

Stress  rupture  of  fasteners 

FA/260      ASTM  El 39 

FA/261  ASTME292 


NVLAP  1999  DIRECTORY  -  Page  D124 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


FA/262  MIL-STD-1312-10 

Tension  testing  of  machined  specimens  from  externally 
threaded  fasteners 

FA/278      ASTM  A3  70 
FA/279      ASTM  F606  Sec.  3.6 
FA/475      ASTM  E8 

Test  for  embrittlement  of  metallic  coated  externally 

threaded  fasteners 

FA/179      ASTM  F606  Sec.  7 

FA/525  MIL-STD-1312-5 

Torque-out  test 

FA/133  MIL-N-25027 

FA/523  MIL-STD-1312-31 

Torque-tension  of full-size  threaded  fasteners 

FA/307  MIL-STD-1312-15 

Vibration  of full-size  threaded  fasteners 

FA/311  MIL-STD-1312-7 

FA/631  MIL-N-25027 

Vickers  hardness  -  test  forces  from  9.807  to  1176  N  (1  to 
120  kgf) 

FA/492      ASTM  E92 

Wedge  tensile  strength  of full-size  threaded  fasteners 
FA/289      ASTM  A370 
FA/290      ASTM  F606  Sec.  3.5 

Wrench  torque  test  of  externally  wrenched  nuts  of  spline 
and  hexagon  and  double  hexagon  (1 
FA/141  MIL-N-25027 
FA/524  MIL-STD-1312-31 

Yield  strength  of full-size  externally  threaded  fasteners 

FA/298       ASTM  F606  Sec.  3.2.4 
FA/299      ASTM  A370  Sec.  A3.2. 1 .3(a) 

Metallography 

Decarburization  and  case  depth  measurement  in 
fasteners 

FA/323      ASTM  El 077 
Determination  of  grain  size  of fasteners 

FA/638      ASTM  El  12 

Macroscopic  examination  of  fasteners  by  etching 
FA/511  ASTME340 

Microscopic  examination  of  fasteners  by  etching 
FA/512  ASTME407 

Surface  discontinuities  of  externally  threaded  fasteners 

FA/357      ASTM  F788/788M 

Surface  discontinuities  of  internally  threaded  fasteners 
FA/363       ASTM  F8 12 
Nondestructive  Inspection 

Liquid  penetrant  inspection  of  fasteners 

FA/371  MIL-STD-6866 

FA/527       ASTM  E1417 

Magnetic  particle  inspection  of  fasteners 

FA/485       ASTM  El 444 


NVLAP  LAB  CODE  200165-0 
Metropolitan  Environmental  Testing  Services  dba 
METS  Laboratories 

179  Smallwood  Village  Center 
Waldorf,  MD  20602 
Contact:  Ms.  Robin  Grey 
Phone:  301-870-1995 
Fax:  301-870-1701 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  200166-0 
O  &  K  Company  Limited,  Osaka  Test  Center 

8-81,  Nakajima  2-Chome,  Nishiyodogawa-Ku 

Osaka-Shi 

JAPAN 

Contact:  Mr.  Norio  Shiga 
Phone:  06-471-0110 
Fax:  06-472-0554 


Fasteners  &  Metals 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 
Chemical  Analysis 

Optical  emission  spectro chemical  analysis 
FA/457      ASTM  E4 15 

NVLAP  LAB  CODE  200167-0 
Bay  Area  Compliance  Laboratory,  Corp. 

230  Commercial  Street,  Suite  2 
Sunnyvale,  CA  94086 
Contact:  Mr.  John  Y.  Chan 
Phone:  408-732-9162 
Fax:  408-732-9164 


FCC  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/F0 1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

12/F01a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
12/F01b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 


NVLAP  1999  DIRECTORY  -  Page  D125 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200168-0 
Portland  Bolt  and  Manufacturing  Company,  Inc. 
Testing  Laboratory 

3441  N.W.  Guam  Street 
P.O.  Box  2866 
Portland,  OR  97208-2866 
Contact:  Mr.  Dan  Herboth 
Phone:  503-227-5488 
Fax:  503-227-4634 


Fasteners  &  Metals 

Accreditation  Valid  Through:  March  31,  1999 
NVLAP 

Code  Designation 

Mechanical  and  Physical  Testing  and  Inspection 

Axial  tensile  strength  of full-size  threaded  fasteners 

FA/266       ASTMF606  Sec.  3.4.1-3.4.3 
FA/273       SAE  J429 

Proof  load  of  full-size  externally  threaded  fasteners 

FA/226      ASTMF606  Sec.  3.2.1-3.2.3 

FA/229       SAE  J429  Sec.  5.3 

Rockwell  hardness  of  fasteners 

FA/ 197  ASTME18 

Rotational  capacity  of full-size  fasteners 

FA/245       ASTM  A563 

Tension  testing  of  machined  specimens  from  externally 
threaded  fasteners 

FA/279       ASTM  F606  Sec.  3.6 
FA/283       SAE  J429 

Wedge  tensile  strength  of  full-size  threaded  fasteners 

FA/290       ASTM  F606  Sec.  3.5 
FA/468       SAE  J429  Sec.  5.5 

NVLAP  LAB  CODE  200169-0 
Kobelco  Research  Institute,  Inc.  Stock  Company 

2  Nadahama-Higashimachi,  Nada-ku 

Kobe  657-0863 

JAPAN 

Contact:  Mr.  Morifumi  Nakamura 
Phone:  81-78-882-8058 
Fax:  81-78-882-8211 


Fasteners  &  Metals 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 
Chemical  Analysis 

Combustion  analysis  for  carbon,  sulfur,  oxygen, 
nitrogen,  and  hydrogen 
FA/586  JISG1211 
FA/587  JISG1215 


Optical  emission  spectrochemical  analysis 

FA/588  JISG1253 
Solution  chemical  analysis 

FA/585  JISG1258 

NVLAP  LAB  CODE  200171-0 
Leland-Powell  Fasteners,  Inc.  Fastener  Testing 
Laboratory 

Highway  45  South 
P.O.  Box  260 
Martin,  TN  38237 
Contact:  Mr.  Jason  Danner 
Phone:  901-587-3106 
Fax:  901-587-9613 
E-Mail:  jason@lpf.net 

Fasteners  &  Metals 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 
Dimensional  Inspection 

Dimensions  of  fasteners  -  straightness 

FA/754       IFI  138 

Dimensions  of  general  purpose  fasteners  and 

high-volume  machine  assembly  fasteners 

FA/404      ANSI/ASME  B18.18.2M 

Dimensions  of  special  purpose  fasteners  and  fasteners  for 

highly  specialized  engineered  ap 

FA/405       ANSI/ASME  Bl 8.1 8. 3M 

External  thread  parameters  -  system  22 

FA/381       ANSI/ASME  B1.3M 

Mechanical  and  Physical  Testing  and  Inspection 

Axial  tensile  strength  of full-size  threaded  fasteners 

FA/273       SAE  J429 
FA/752       SAE  J82 
Drive  test 

FA/248  SAEJ81 
FA/750       SAE  J933 

Ductility  test  of  thread  rolling  and  self-drilling  tappings 
screws 

FA/250  SAEJ81 

Hydrogen  embrittlement  (stress  durability)  of  externally 
threaded  fasteners 

FA/709       SAE  J81  Sec.  3.9 

Measurement  of  fastener  coating  thickness  -  eddy-current 
method 

FA/149       ASTM  E376 

Proof  load  of  full-size  externally  threaded  fasteners 

FA/229       SAE  J429  Sec.  5.3 

Rockwell  hardness  of  fasteners 

FA/202  SAEJ417 

Rockwell  superficial  hardness  of  fasteners 

FA/210  SAEJ417 

Torsional  strength  test  of  thread  rolling  and  self-drilling 
tappings  screws 

FA/254  SAEJ81 
FA/751  SAEJ933 


NVLAP  1999  DIRECTORY  -  Page  D126 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Wedge  tensile  strength  of full-size  threaded  fasteners 

FA/468       SAE  J429  Sec.  5.5 
FA/753       SAE  J82 

NVLAP  LAB  CODE  200172-0 
Rockford  Engineering  Services,  Inc. 

2100  Calaveras  Road 

P.O.  Box  543 

Sunol,  CA  94586-0543 

Contact:  Mr.  Michael  Gbadebo 

Phone:  510-862-2944 

Fax:  510-862-9013 

E-Mail:  mike@rockfordengr.com 

URL:  http://www.resemc.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
12/F01       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

12/F01a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
12/F01b      Radiated  Emissions 
12/T01       Terminal  Equipment  Network  Protection 

Standards,  FCC  Method  -  47  CFR  Part  68  - 

Analog  and  Digital 
12/T01a     68.302  (Par.  c,d,e,f)  Environmental  simulation; 

68.304  Leakage  current  limit.;  68.306 

Hazardous  voltage  limit.;  68.308  Signal  power 

limit.;  68.310  Longitudinal  balance  limit.; 

68.312  On-hook  impedance  limit.;  68.314 

Billing  protection 
12/T01b     68.316  Hearing  Aid  Compatibility:  technical 

standards 

12/TOlc      68.302  Environmental  simulation  (Par.  a,b) 
International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 


NVLAP  LAB  CODE  200173-0 

Fuserashi  Gunma 

870  Kamieda,  Nitta-Cho,  Nitta-Gun 

Gunma-Ken  370-03 

JAPAN 

Contact:  Mr.  Takeo  Okada 
Phone: 06-789-7121 
Fax:  06-781-1734 


Fasteners  &  Metals 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

Dimensional  Inspection 

Dimensions  of  ISO  grade  A  and  B  fasteners 
FA/608  JISB1181 
Dimensions  of  ISO  grade  C  fasteners 
FA/609  JISB1181 

Dimensions  of fasteners  -  flange  screw  heads  and  flange 
nuts 

FA/610  JISB1190 

Dimensions  of  general  purpose  fasteners  and 

high-volume  machine  assembly  fasteners 

FA/607  JISB1071 

External  thread  parameters  -  ISO 

FA/624      JIS  B0252 

Internal  thread  parameters  -  ISO 

FA/605       JIS  B025 1 

FA/606      JIS  B0252 

Mechanical  and  Physical  Testing  and  Inspection 

Adhesion  of  metallic  coatings  on  fasteners 
FA/595       JIS  H8504 

CASS  test  (copper-accelerated  acetic  acid-salt  spray  test) 
of fasteners 

FA/599      JIS  H8502 

Measurement  of  fastener  coating  thickness  -  coulometric 
method 

FA/597  JISH8501 

Measurement  of  fastener  coating  thickness  -  magnetic 
methods 

FA/596      JIS  H8501 
Prevailing  torque 

FA/600      JIS  B 1056 

Proof  load  of full-size  externally  threaded  fasteners 

FA/573       JIS  B1051  Sec.  4.2.4 

Proof  load  of  internally  threaded  fasteners  (nuts) 

FA/601       JIS  B 1052 

Rockwell  hardness  of  fasteners 

FA/572      JIS  Z2245 

Salt  spray  testing  of  fasteners 

FA/569  JISZ2371 

FA/598       JIS  H8502 


NVLAP  1999  DIRECTORY  -  Page  D127 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Vickers  hardness  -  test  forces  from  9.807  to  1 176  /V  (1  to 
120  kgf) 

FA/571  JISZ2244 
Metallography 

Macroscopic  examination  of  fasteners  by  etching 

FA/602       JIS  G0553 

Surface  discontinuities  of  externally  threaded  fasteners 
FA/603       JIS  B 1043 

Surface  discontinuities  of  internally  threaded  fasteners 
FA/604      JIS  B 1042 

NVLAP  LAB  CODE  200174-0 
Training  Research  Co.,  Ltd. 

No.  571,  5F,  Chung  Shiao  E.  Rd.,  Sec.  7 
P.O.  Box  No.  4-18,  Nang  Kang 
Taipei 
TAIWAN 

Contact:  Mr.  Frank  Tsai 

Phone:  886-2-2788-1332 

Fax:  886-2-2785-7408 

E-Mail:  a9493666@ms21.hinet.net 

FCC  Test  Methods 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/F0 1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

12/F01a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
12/F01b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200175-0 
Ohtama  Co.,  Ltd.  Yamanashi  EMC  Test  Site 

1661  Oshuku  Asigawa  Higashi-Yatsushiro 

Yamanashi 

JAPAN 

Contact:  Mr.  Etsuji  Nogami 
Phone:  81-552-98-2141 
Fax:  81-552-98-2125 


FCC  Test  Methods 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 


Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/F0 1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO 1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200177-0 
Korea  Testing  &  Research  Inst,  for  Chemical 
Industry-Inchon  Off. 

GAJOA  3  DONG  539-8 
Inchon  404-253 
KOREA 

Contact:  Mr.  Kwang-Yeon  Lee 
Phone:  82-32-577-6801 
Fax:  82-32-575-5613 


Fasteners  &  Metals 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 
Chemical  Analysis 

Combustion  analysis  for  carbon,  sulfur,  oxygen, 

nitrogen,  and  hydrogen 

FA/455  ASTME1019 

Optical  emission  spectrochemical  analysis 

FA/457  ASTME415 

Solution  chemical  analysis 

FA/448       ASTM  E350 

Dimensional  Inspection 

Dimensions  of  fasteners  -  straightness 

FA/423       ANSI/ASME  B 1 8.2. 1 

Dimensions  of  general  purpose  fasteners  and 

high-volume  machine  assembly  fasteners 

FA/486       MIL-STD-120  (W/  Notice  dtd  9  SEP  63) 

Dimensions  of  special  purpose  fasteners  and  fasteners  for 

highly  specialized  engineered  ap 

FA/493      MIL-STD- 1 20  ( W/  Notice  dtd  9SEP  63) 

External  thread  parameters  -  system  21 

FA/379       ANSI/ASME  B1.3M 

External  thread  parameters  -  system  22 

FA/381       ANSI/ASME  B1.3M 

Internal  thread  parameters  -  system  21 

FA/39 1       ANSI/ASME  B1.3M 

Internal  thread  parameters  -  system  22 

FA/393       ANSI/ASME  B 1 .3M 


NVLAP  1999  DIRECTORY  -  Page  D128 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Mechanical  and  Physical  Testing  and  Inspection 

Axial  tensile  strength  of  full-size  threaded  fasteners 
FA/266      ASTM  F606  Sec.  3.4.1-3.4.3 
FA/267      ASTM  F606M  Sec.  3.4. 1-3.4.3 
Brinell  hardness  of  fasteners 
FA/186      ASTM  El 0 
Charpy  impact  (u-notch)  testing 
FA/517  ASTME23 
Charpy  impact  (v-notch)  testing 
FA/212      ASTM  E23 

Cone  proof  load  of  internally  threaded  fasteners  (nuts) 
FA/220      ASTM  F606  Sec.  4.3 
FA/22 1       ASTM  F606M  Sec.  4.3 
Measurement  of  fastener  coating  thickness  -  X-ray 
methods 

FA/760      ASTM  A754/A754M 

Measurement  of  fastener  coating  thickness  -  magnetic 

methods 

FA/153       ASTM  B499 

Measurement  of  fastener  coating  thickness  -  weight  of 
coating 

FA/164      ASTM  A90 
Microhardness  of  fasteners 
FA/ 189      ASTM  E3  84 

Proof  load  of full-size  externally  threaded  fasteners 
FA/226      ASTM  F606  Sec.  3.2.1-3.2.3 
FA/467      ASTM  F606M  Sec.  3.2.1-3.2.3 
Proof  load  of  internally  threaded  fasteners  (nuts) 
FA/236      ASTM  F606  Sec.  4.2 
FA/237      ASTM  F606M  Sec.  4.2 
Rockwell  hardness  of  fasteners 
FA/197      ASTM  El  8 
Salt  spray  testing  of  fasteners 
FA/166      ASTM  Bl  17 

Tension  testing  of  machined  specimens  from  externally 
threaded  fasteners 

FA/279      ASTM  F606  Sec.  3.6 

FA/280      ASTM  F606M  Sec.  3.6 

Wedge  tensile  strength  of full-size  threaded  fasteners 

FA/290      ASTM  F606  Sec.  3.5 

FA/291       ASTM  F606M  Sec.  3.5 

Yield  strength  of full-size  externally  threaded  fasteners 

FA/298      ASTM  F606  Sec.  3.2.4 

FA/300      ASTM  F606M  Sec.  3.2.4 

Metallography 

Decarburization  and  case  depth  measurement  in 
fasteners 

FA/323      ASTM  El 077 
Determination  of  grain  size  of  fasteners 
FA/638      ASTM  El  12 

Macroscopic  examination  of  fasteners  by  etching 
FA/511  ASTME340 

Microscopic  examination  of  fasteners  by  etching 
FA/512  ASTME407 

Surface  discontinuities  of  externally  threaded  fasteners 

FA/357      ASTM  F788/788M 


Surface  discontinuities  of  internally  threaded  fasteners 
FA/865       ASTM  F8 1 2/F8 1 2M 

NVLAP  LAB  CODE  200178-0 
Durkee  Testing  Laboratories,  Inc. 

15700  Texaco  Street 
P.O.  Box  1401 
Paramount,  CA  90723-1401 
Contact:  Mr.  John  A.  Durkee 
Phone:  562-531-71  11 
Fax:  562-531-7137 
E-Mail:  durkee@IBM.net 

Fasteners  &  Metals 

Accreditation  Valid  Through:  March  31,  1999 
NVLAP 

Code  Designation 
Chemical  Analysis 

Combustion  analysis  for  carbon,  sulfur,  oxygen, 
nitrogen,  and  hydrogen 

FA/455       ASTM  E1019 

FA/472      ASTM  El 447 

FA/513       ASTM  El 409 

FA/514      ASTME351  Sec.  37 

FA/515       ASTM  E352  Sec.  36 

FA/516       ASTM  E3 5 3  Sec.  37 

Energy  dispersive  X-ray  analysis 

FA/500      ASTM  El 508 

Optical  emission  spectrochemical  analysis 

FA/457      ASTM  E4 15 

FA/458      ASTM  E607 

FA/459      ASTM  El 086 

Spot  test  analysis 

FA/501       ASTM  STP550 

Mechanical  and  Physical  Testing  and  Inspection 

Adhesion  of  metallic  coatings  on  fasteners 
FA/143       ASTM  B5 71 

Axial  tensile  strength  of full-size  threaded  fasteners 

FA/271  MIL-STD-1312-8 

Bend  test  of  full  size  eyebolts 

FA/503       ASTM  A370  Sec.  14 

Breaking  strength  of  fullsize  eyebolts 

FA/508  MIL-STD-1312-8 

Brinell  hardness  of  fasteners 

FA/ 186      ASTM  El 0 

CASS  test  (copper-accelerated  acetic  acid-salt  spray  test) 
of  fasteners 

FA/496      ASTM  B368 
Charpy  impact  (u-notch)  testing 
FA/517  ASTME23 
Charpy  impact  (v-notch)  testing 

FA/21 1       ASTM  A370  Sec.  19-28 
FA/212  ASTME23 

Copper  sulfate  test  -  test  for  free  iron  on  the  surface  of 
corrosion  resistant  fasteners 

FA/499      ASTM  A3 80 


NVLAP  1999  DIRECTORY  -  Page  D129 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Double  shear  of  externally  threaded  fasteners 
FA/257       MIL-STD-13 12-13 
Elevated  temperature  testing  capability 
FA/505       MIL-STD-13 12-1 8 
Fatigue  of  full-size  threaded  fasteners 
FA/183       MIL-STD-13 12-11 
Humidity  testing  of  fasteners 
FA/473       MIL-STD-13 12-3 

Hydrogen  embrittlement  (stress  durability)  of  externally 

threaded  fasteners 

FA/ 176       MIL-STD-13 12-5 

Hydrogen  embrittlement  (stress  durability)  of  internally 

threaded  fasteners 

FA/ 178       MIL-STD-13 12-14 

Intergranular  corrosion  susceptibility  in  austentic 

stainless  steel  fasteners  -  nitric  aci 

FA/ 173       ASTM  A262  Sec.  15-21 ,  Practice  C 

FA/504      ASTM  G28 

Intergranular  corrosion  susceptibility  of  austentic 
stainles  steel  fasteners  -  oxalic  acid 

FA/1 74      ASTM  A262  Sec.  3-7,  Practice  A 

Lock  torque  tests 

FA/480      MIL-STD-13 12-31 

Measurement  of  fastener  coating  thickness  -  dimensional 

change  method 

FA/495       MIL-STD-13 12- 12 

Measurement  of  fastener  coating  thickness  -  magnetic 
methods 

FA/159       MIL-STD-13 12-1 2 
Measurement  of  fastener  coating  thickness  - 
microscopical  method 
FA/163       MIL-STD-13 12-12 

Measurement  of  fastener  coating  thickness  -  weight  of 
coating 

FA/165  MIL-STD-1312-12 

Microhardness  of  fasteners 

FA/ 193       MIL-STD-13 12-6 

Proof  load  of  full-size  externally  threaded  fasteners 

FA/226       ASTM  F606  Sec.  3.2.1-3.2.3 

Proof  load  of full-size  eyebolts 

FA/232  ASTMF541 

Proof  load  of  internally  threaded  fasteners  (nuts) 

FA/236       ASTM  F606  Sec.  4.2 

Push  out  test  of  floating  plate  nuts,  gang  channel  nuts, 
and  anchor  nuts 
FA/116  MIL-N-25027 

Recess  strength  test  in  both  the  installation  and  removal 
directions 

FA/476       MIL-STD-13 12-25 
Rockwell  hardness  of  fasteners 
FA/201       MIL-STD-13 12-6 
Rockwell  superficial  hardness  of  fasteners 
FA/209       MIL-STD-13 12-6 
Salt  spray  testing  of  fasteners 
FA/166       ASTM  Bl  17 
FA/168  MIL-STD-1312-1 


Single  shear  of  externally  threaded  fasteners 

FA/256      MIL-STD-13 12-20 

Stress  corrosion  of  fasteners 

FA/ 172       MIL-STD-13 12-9 

Stress  rupture  of  fasteners 

FA/262       MIL-STD-13 12-10 

Test  for  embrittlement  of  metallic  coated  externally 

threaded  fasteners 

FA/506       ASTM  F5 19 

Torque-out  test 

FA/133  MIL-N-25027 

FA/502  MIL-N-45913 

Vibration  of full-size  threaded  fasteners 

FA/311       MIL-STD-13 12-7 

Vickers  hardness  -  test  forces  from  9.807  to  11 76  N  (1  to 
120  kgf) 

FA/507      ASTM  E384 

Water  immersion  method  -  test  for  anodic  surface 
containment  on  corrosion  resistant  fasten 

FA/497       ASTM  A262 
FA/498  ASTMG31 

Wedge  tensile  strength  of full-size  threaded  fasteners 

FA/290      ASTM  F606  Sec.  3.5 
FA/510  ASTME8 

Yield  strength  of full-size  externally  threaded  fasteners 

FA/593       ASTM  E8 
Metallography 

Decarburization  and  case  depth  measurement  in 
fasteners 

FA/483       ASTM  A574  Sec.  12 
FA/520      ASTM  F835 
Determination  of  grain  size  of fasteners 
FA/331       ASTM  El  12 

Macroscopic  examination  of  fasteners  by  etching 
FA/511  ASTME340 

Microscopic  examination  of  fasteners  by  etching 

FA/512  ASTME407 

Surface  discontinuities  of  externally  threaded  fasteners 

FA/357      ASTM  F788 

Surface  discontinuities  of  internally  threaded  fasteners 

FA/363       ASTM  F8 12 

NVLAP  LAB  CODE  200179-0 
Fastener  Innovation  Technology,  Inc. 

13215  S.  Western  Avenue 
Gardena,  CA  90249-9123 
Contact:  Mr.  Jorge  W.  Molina 
Phone:  310-538-1111 
Fax:  310-324-7602 
E-Mail:  JWM@fltfastener.com 

Fasteners  &  Metals 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 
Dimensional  Inspection 


NVLAP  1999  DIRECTORY  -  Page  D130 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Dimensions  of fasteners  -  hexagon  and  double  hexagon 

(12  point)  and  spline  sockets 

FA/411       ANSI/ASME  B18.3 

External  thread  parameters  -  ISO 

FA/594  FED-STD-H28/21 

External  thread  parameters  -  system  21 

FA/380  FED-STD-H28/20 

External  thread  parameters  -  system  22 

FA/382  FED-STD-H28/20 

External  thread  parameters  -  system  23 

FA/386  FED-STD-H28/20 

Surface  texture 

FA/439      ANSI/ASME  B46.1 

Mechanical  and  Physical  Testing  and  Inspection 

Axial  tensile  strength  of full-size  threaded  fasteners 
FA/271  MIL-STD-1312-8 
FA/530      ASTM  E8 

Copper  sulfate  test  -  test  for  free  iron  on  the  surface  of 

corrosion  resistant  fasteners 

FA/499      ASTM  A3  80 

Double  shear  of  externally  threaded  fasteners 

FA/257  MIL-STD-1312-13 

Elevated  temperature  testing  capability 

FA/505  MIL-STD-1312-18 

Fatigue  of  full-size  threaded  fasteners 

FA/ 183  MIL-STD-1312-11 

Hydrogen  embrittlement  (stress  durability)  of  externally 

threaded  fasteners 

FA/176  MIL-STD-1312-5 

Magnetic  permeability 

FA/215  MIL-I-17214 

Measurement  of  fastener  coating  thickness  - 

microscopical  method 

FA/591       ASTM  El  182 

Microhardness  of  fasteners 

FA/189  ASTME384 

FA/193  MIL-STD-1312-6 

Proof  load  of full-size  externally  threaded  fasteners 

FA/226      ASTM  F606  Sec.  3.2.1-3.2.3 

Recess  strength  test  in  both  the  installation  and  removal 

directions 

FA/476  MIL-STD-1312-25 

Reusability  test  of  self-locking  internally  threaded 

fasteners 

FA/124  MIL-N-25027 

Rockwell  hardness  of  fasteners 

FA/201  MIL-STD-1312-6 

Rockwell  superficial  hardness  of  fasteners 

FA/209  MIL-STD-1312-6 

Salt  spray  testing  of  fasteners 

FA/166      ASTM  Bl  17 

Single  shear  of  externally  threaded  fasteners 

FA/256  MIL-STD-1312-20 

Stress  corrosion  of  fasteners 

FA/172  MIL-STD-1312-9 


Stress  rupture  of  fasteners 
FA/262  MIL-STD-1312-10 

Tension  testing  of  machined  specimens  from  externally 
threaded  fasteners 
FA/475       ASTM  E8 
FA/526  MIL-STD-1312-8 
Total  extension  at  fracture  of  externally  threaded 
fasteners 

FA/592      ASTM  E8 

Wedge  tensile  strength  of full-size  threaded  fasteners 

FA/289      ASTM  A3 70 
FA/290      ASTM  F606  Sec.  3.5 

Wrench  torque  test  of  externally  wrenched  nuts  of  spline 
and  hexagon  and  double  hexagon  (1 

FA/141  MIL-N-25027 

Yield  strength  of full-size  externally  threaded  fasteners 

FA/593       ASTM  E8 

Metallography 

Decarburization  and  case  depth  measurement  in 
fasteners 

FA/323       ASTM  El 077 
Determination  of  grain  size  of fasteners 

FA/331       ASTM  El  12 

Macroscopic  examination  of  fasteners  by  etching 

FA/5 1 1       ASTM  E340 

Microscopic  examination  of  fasteners  by  etching 

FA/512  ASTME407 

Surface  discontinuities  of  externally  threaded  fasteners 

FA/357      ASTM  F788/788M 

Nondestructive  Inspection 

Liquid  penetrant  inspection  of  fasteners 

FA/371  MIL-STD-6866 

FA/527      ASTM  El 41 7 

Magnetic  particle  inspection  of  fasteners 

FA/485       ASTM  El 444 

NVLAP  LAB  CODE  200180-0 
Fuji  Component  Parts  USA,  Inc. 

4115  West  54th  Street 
Indianapolis,  IN  46254 
Contact:  Mr.  Steve  Egelhoff 
Phone:  317-347-4115 
Fax:  317-347-4123 


Fasteners  &  Metals 

Accreditation  Valid  Through:  March  31,  1999 
NVLAP 

Code  Designation 
Chemical  Analysis 

Optical  emission  spectrochemical  analysis 
FA/457       ASTM  E4 15 
Dimensional  Inspection 

External  thread  parameters  -  system  21 
FA/379      ANSI/ASME  B1.3M 


NVLAP  1999  DIRECTORY  -  Page  D131 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Internal  thread  parameters  -  system  21 

FA/39 1       ANSI/ASME  B 1 .3M 

Mechanical  and  Physical  Testing  and  Inspection 

Axial  tensile  strength  of  full-size  threaded  fasteners 
FA/266       ASTM  F606  Sec.  3.4.1-3.4.3 
Measurement  of  fastener  coating  thickness  -  coulometric 
method 

FA/567       ASTM  B504 
Microhardness  of  fasteners 
FA/657      ASTM  E92 

Proof  load  of  full-size  externally  threaded  fasteners 

FA/226      ASTM  F606  Sec.  3.2.1-3.2.3 

Proof  load  of  internally  threaded  fasteners  (nuts) 

FA/236      ASTM  F606  Sec.  4.2 

Rockwell  hardness  of  fasteners 

FA/ 197       ASTM  El 8 

Salt  spray  testing  of  fasteners 

FA/166       ASTM  Bl  17 

Wedge  tensile  strength  of full-size  threaded  fasteners 

FA/290      ASTM  F606  Sec.  3.5 

Yield  strength  of  full-size  externally  threaded  fasteners 

FA/298       ASTM  F606  Sec.  3.2.4  

NVLAP  LAB  CODE  200181-0 

Topura  Co.,  Ltd. 
201  Soya 

Hadano  Kanagawa  257-8686 
JAPAN 

Contact:  Mr.  Katsuzo  Fujihira 
Phone:  0463-82-4179 
Fax:  0463-82-6169 


Fasteners  &  Metals 

Accreditation  Valid  Through:  September  30,  1999 

NVLAP 

Code  Designation 
Dimensional  Inspection 

Dimensions  of  general  purpose  fasteners  and 
high-volume  machine  assembly  fasteners 
FA/607  JISB1071 
FA/675  JISB1012 
FA/682  JASOF116 
External  thread  parameters  -  ISO 
FA/676  JISB1071 

Mechanical  and  Physical  Testing  and  Inspection 

Axial  tensile  strength  of full-size  threaded  fasteners 

FA/574      JIS  B 1051  Sec.  4.2.2 

FA/672      JIS  B 1054 

Emhrittlement  test  of  washers 

FA/673  J1SB1252 

Head  soundness  testing 

FA/615       JIS  Bl 051  Sec.  4.2.6 

Measurement  of  fastener  coating  thickness  -  eddy-current 

method 

FA/618  JISH8501 


Measurement  of  fastener  coating  thickness  -  weight  of 
coating 

FA/619  JISH8501 
Microhardness  of  fasteners 

FA/620      JIS  Z2244 

Proof  load  of  full-size  externally  threaded  fasteners 

FA/573       JIS  B 1051  Sec.  4.2.4 

Recovery  test  of  washers 

FA/674      JIS  B 1252 

FA/677      JIS  B 1251 

Rockwell  hardness  of  fasteners 

FA/707      JIS  B 1051  Sec.  4.2.5 

Salt  spray  testing  of  fasteners 

FA/569  JISZ2371 

FA/598       JIS  H8502 

Twist  test  of  lock  washers 

FA/678       JIS  B 1251 

Wedge  tensile  strength  of  full-size  threaded  fasteners 
FA/575       JIS  B1051  Sec.  4.2.3 
Metallography 

Decarburization  and  case  depth  measurement  in 
fasteners 

FA/645       JIS  B 1051 

Surface  discontinuities  of  externally  threaded  fasteners 

FA/603  JIS  B 1043 
FA/646       JIS  B 1041 

NVLAP  LAB  CODE  200183-0 
California  Screw  Products 

14957  Gwenchris  Court 
Paramount,  CA  90723-3423 
Contact:  Mr.  Ralph  Terrazas 
Phone:  562-633-6626 
Fax:  562-633-2082 


Fasteners  &  Metals 

Accreditation  Valid  Through:  March  31,  1999 

NVLAP 

Code  Designation 
Dimensional  Inspection 

Dimensions  of  fasteners  -  straightness 

FA/423       ANSI/ASME  B  18.2.1 

External  thread  parameters  -  SAE  fastener  with  MJ 

metric  screw  threads 

FA/922       ANSI/ASME  B1.3M 

External  thread  parameters  -  system  22 

FA/381       ANSI/ASME  B1.3M 

External  thread  parameters  -  system  23 

FA/385       ANSI/ASME  B1.3M 

Mechanical  and  Physical  Testing  and  Inspection 

Axial  tensile  strength  of full-size  threaded  fasteners 
FA/799      NASM  1312-8 
Double  shear  of  externally  threaded  fasteners 
FA/880      NASM  1312-13 


NVLAP  1999  DIRECTORY  -  Page  D132 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Fatigue  of full-size  threaded  fasteners 
FA/876      NASM  1312-11 

Hydrogen  embrittlement  (stress  durability)  of  externally 

threaded  fasteners 

FA/875      NASM  1312-5 

Magnetic  permeability 

FA/214      ASTM  A342  Test  Method  3 

Measurement  of  fastener  coating  thickness  -  dimensional 

change  method 

FA/874      NASM  1312-12 

Measurement  of  fastener  coating  thickness  -  eddy-current 
method 

FA/872      NASM  1312-12 

Measurement  of  fastener  coating  thickness  - 

microscopical  method 

FA/873      NASM  1312-12 

Microhardness  of  fasteners 

FA/877      NASM  1312-6 

Recess  strength  test  in  both  the  installation  and  removal 
directions 

FA/886      NASM  1312-25 

Rockwell  hardness  of  fasteners 

FA/878      NASM  1312-6 

Single  shear  of  externally  threaded  fasteners 

FA/879      NASM  1312-20 

Stress  rupture  of  fasteners 

FA/881       NASM  1312-10 

Metallography 

Decarbut ization  and  case  depth  measurement  in 
fasteners 

FA/328  SAEJ121 

Determination  of  grain  size  of fasteners 

FA/331       ASTM  El  12 

Macroscopic  examination  of  fasteners  by  etching 
FA/511  ASTME340 

Microscopic  examination  of  fasteners  by  etching 
FA/512  ASTME407 

Surface  discontinuities  of  externally  threaded  fasteners 
FA/357      ASTM  F788/788M 

NVLAP  LAB  CODE  200184-0 

NSS  Technologies 

9075  General  Drive 
Plymouth,  MI  48170-4623 
Contact:  Mr.  Darrin  Keener 
Phone:  313-416-5721 
Fax:313-453-0690 


Fasteners  &  Metals 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 
Dimensional  Inspection 


Dimensions  of  general  purpose  fasteners  and 
high-volume  machine  assembly  fasteners 

FB/1083  NSSTIM-0006 
FB/1084  NSSTIM-0007 
FB/1085  NSSTIM-0008 
FB/1086  NSSTIM-0009 
External  thread  parameters  -  system  21 
FA/379      ANSI/ASME  B1.3M 
FB/1079  NSSTIM-0010 
External  thread  parameters  -  system  22 
FA/381       ANSI/ASME  B1.3M 
FB/1080  NSSTIM-0010 
Internal  thread  parameters  -  system  21 
FA/391       ANSI/ASME  B1.3M 
FB/1081  NSSTIM-0010 
Internal  thread  parameters  -  system  22 
FA/393       ANSI/ASME  Bl. 3 M 
FB/1082  NSSTIM-0010 

Mechanical  and  Physical  Testing  and  Inspection 

Axial  tensile  strength  of full-size  threaded  fasteners 

FA/266      ASTM  F606  Sec.  3.4.1-3.4.3 
FA/267      ASTM  F606M  Sec.  3.4.1-3.4.3 
FA/273       SAE  J429 
FA/578       SAE  J1216  Sec.  3.5 
FB/1089  SAEJ995 

Proof  load  of full-size  externally  threaded  fasteners 

FA/226      ASTM  F606  Sec.  3.2.1-3.2.3 

FA/229       SAE  J429 

FA/467      ASTM  F606M  Sec.  3.2. 1-3.2.3 

FA/577       SAE  J1216  Sec.  3.3 

FB/1087     ANSI/A WWA  CI  11/A2 1.11 

Proof  load  of  internally  threaded  fasteners  (nuts) 

FA/236       ASTM  F606  Sec.  4.2 

FA/237      ASTM  F606M  Sec.  4.2 

FA/241       SAE  J995  Sec.  5.1 

FB/1088     ANSI/A  WWA  CI  11/A2 1.11 

Rockwell  hardness  of  fasteners 

FA/197       ASTM  El 8 

Metallography 

Surface  discontinuities  of  externally  threaded  fasteners 

FA/357       ASTM  F788/788M 
FA/361  SAEJ123 
FB/1090     Chrysler  PF-5 188 

Surface  discontinuities  of  internally  threaded  fasteners 

FA/703       SAE  J 122 

FA/865       ASTM  F8 1 2/F8 1 2M 

FB/1091     Chrysler  PF-5 189 

Nondestructive  Inspection 

Magnetic  particle  inspection  of  fasteners 

FA/374      ASTM  E709 
FA/485       ASTM  El 444 


NVLAP  1999  DDRECTORY  -  Page  D133 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  200185-0 
Acominas  -  Analysis  and  Testing  Laboratory 

Rodovia  MG,  443  -  km  05 
Ouro  Branco  MG  36420.000 
BRAZIL 

Contact:  Mr.  Dalvio  Correia  Mourao 

Phone:  55-31-749-3334 

Fax:  55-31-749-3302 

E-Mail:  dalvio@acominas.com.br 

Fasteners  &  Metals 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 
Chemical  Analysis 

Combustion  analysis  for  carbon,  sulfur,  oxygen, 

nitrogen,  and  hydrogen 

FA/455  ASTME1019 

Optical  emission  spectrochemical  analysis 

FA/457  ASTME415 

Solution  chemical  analysis 

FA/448       ASTM  E350 

X-ray  fluorescence  (XRF)  spectrochemical  analysis 

FA/463       ASTM  El 085 

NVLAP  LAB  CODE  200186-0 
Hitachi  Information  Technology  Co.,  Ltd.  Nakai 
Test  Site 

Nakai  Test  Site 

456  Sakai,  Nakai-machi,  Ashigarakami-gun 

Kanagawa  259-0157 

JAPAN 

Contact:  Mr.  Seiichi  Kawashima 
Phone:  81-463-88-1311 
Fax:  81-463-87-1723 


FCC  Test  Methods 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/F0 lb      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 


NVLAP  LAB  CODE  200187-0 

Arden  Fasteners 

901  South  Rohlwing  Road,  Unit  J 

Addison,  IL  60101-4241 

Contact:  Mr.  Michael  J.  Stevens 

Phone:  612-482-7445 

Fax:  612-483-1470 

E-Mail:  mikes@arden-fas.com 

Fasteners  &  Metals 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 
Dimensional  Inspection 

Dimensions  of fasteners  -  flange  screw  heads  and  flange 
nuts 

FA/566       IFID21p.  D21 
FA/712  IFI111 

Dimensions  of  fasteners  -  hexagon  and  double  hexagon 

(12  point)  and  spline  sockets 

FA/718  IFI115 

FA/719  ANSI/ASMEB1.1 

Dimensions  of  general  purpose  fasteners  and 

high-volume  machine  assembly  fasteners 

FA/403       ANSI/ASME  B 1 8. 1 8. 1 M 

FA/404       ANSI/ASME  Bl 8.1 8. 2M 

Mechanical  and  Physical  Testing  and  Inspection 

Axial  tensile  strength  of  full-size  threaded  fasteners 
FA/266       ASTM  F606  Sec.  3 .4. 1  -3 .4.3 
Drill-drive  test 
FA/710  SAEJ78 
FA/711  SAEJ81 
Drive  test 

FA/717       ANSI/ASME  B 18. 6.4 

Ductility  test  of  thread  rolling  and  self-drilling  tappings 
screws 

FA/249       SAE  J78 
FA/250  SAEJ81 
Hardness  preparation 
FA/482      ASTM  F606 

Hydrogen  embrittlement  (stress  durability)  of  externally 
threaded  fasteners 

FA/708       FIP  1 000.6  Fastener  Inspection  Products 
FA/709       SAE  J81  Sec.  3.9 

Measurement  of  fastener  coating  thickness  -  magnetic 
methods 

FA/153  ASTMB499 
Microhardness  of  fasteners 
FA/189  ASTME384 
Prevailing  torque 
FA/217  IFI-100/107 
Rockwell  hardness  of  fasteners 
FA/197       ASTM  El 8 
Salt  spray  testing  of  fasteners 
FA/166      ASTM  Bl  17 


NVLAP  1999  DIRECTORY  -  Page  D134 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Test  for  embrittlement  of  metallic  coated  externally 
threaded  fasteners 
FA/715  SAEJ81 
FA/716      FIP  1000.6 

Torsional  strength  test  of  thread  rolling  and  self-drilling 

tappings  screws 

FA/253       SAE  J78 

FA/254  SAEJ81 

Twist  test  of  lock  washers 

FA/321       ASMEB  18.2 1.1 

Wedge  tensile  strength  of full-size  threaded  fasteners 
FA/290      ASTM  F606  Sec.  3.5 
Metallography 

Decarburization  and  case  depth  measurement  in 
fasteners 

FA/327       SAE  J78 

NVLAP  LAB  CODE  200188-0 
EMSL  Analytical,  Inc. 

6330  East  75th  Street,  Suite  152 
Indianapolis,  IN  46250 
Contact:  Mr.  Richard  Harding 
Phone:  317-570-5892 
Fax:  317-570-5894 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  200189-0 
Japan  Quality  Assurance  Organization  Safety 
Testing  Center 

1-21-25,  Kinuta,  Setagaya-ku 

Tokyo  157-8573 

JAPAN 

Contact:  Mr.  Tateo  Kashiwagi 
Phone:  81-3-3416-0193 
Fax:  81-3-3416-8290 
E-Mail:  JQA00091@nifty.ne.jp 
URL:  http://www/jqq. or.jp 

FCC  Test  Methods 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
12/F01        FCC  Method  -  47  CFR  Part  15  -  Digital 
Devices 

12/F01a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
12/F01b      Radiated  Emissions 


International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200190-0 
Japan  Quality  Assurance  Org.  Chubu  Testing 
Center  Shikatsu  Branch 

53-1,  Yamaura,  Yakushiji,  Shikatsu-cho 

Nishikasugai-gun 

Aichi  481-005 

JAPAN 

Contact:  Mr.  Yasuhiko  Kawakami 
Phone:  81-568-23-0023 
Fax:  81-568-23-0116 

URL:  http://www.jqa.or.jp 

FCC  Test  Methods 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
12/F01        FCC  Method  -  47  CFR  Part  15  -  Digital 
Devices 

12/F01a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
12/F01b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22: 1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200191-0 
Japan  Quality  Assurance  Organization 
Kita-Kansai  Testing  Center 

7-7,  Ishimaru  1-chome,  Minoo-shi 

Osaka  562-0027 

JAPAN 

Contact:  Mr.  Fumio  Matsuda 
Phone:  81-0727-29-2243 
Fax:  81-0727-28-6848 
E-Mail:  JQA00127@nifty.ne.jp 

FCC  Test  Methods 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 


NVLAP  1999  DERECTORY  -  Page  D135 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  la      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200192-0 
Japan  Quality  Assurance  Org.  Safety  Testing  Ctr. 
Tsuru  EMC  Branch 

2096,  Ohata  Tanbozawa,  Tsuru-shi 

Yamanashi  402-0045 

JAPAN 

Contact:  Mr.  Tateo  Kahiwagi 
Phone:  81-3-3416-0193 
Fax:  81-3-3416-8290 
E-Mail:  JQA00091@nifty.ne.jp 
URL:  http://www.jqa.or.jp 

FCC  Test  Methods 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO  1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  la      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200194-0 

TWN  Fastener,  Inc. 

1070  Monterey  Court 
Bowling  Green,  KY  42101 
Contact:  Mr.  Kazuma  Sunagawa 
Phone:  502-781-8500 
Fax:  502-781-3150 


Fasteners  &  Metals 

Accreditation  Valid  Through:  March  31,  1999 
NVLAP 

Code  Designation 


Dimensional  Inspection 

Dimensions  of  general  purpose  fasteners  and 
high-volume  machine  assembly  fasteners 
FA/607  JISB1071 

Mechanical  and  Physical  Testing  and  Inspection 

Axial  tensile  strength  of full-size  threaded  fasteners 

FA/266       ASTMF606  Sec.  3.4.1-3.4.3 
FA/574      JISB 1051  Sec.  4.2.2 
Hardness  preparation 
FA/482      ASTM  F606 

Measurement  of  fastener  coating  thickness  -  magnetic 
methods 

FA/155  ASTME376 
FA/596       JIS  H8501 

Measurement  of  fastener  coating  thickness  -  weight  of 
coating 

FA/619  JISH8501 

Microhardness  of  fasteners 

FA/642      JIS  B1051  Sec.  4.2.5 

Proof  load  of full-size  externally  threaded  fasteners 

FA/226      ASTM  F606  Sec.  3.2. 1-3.2.3 

FA/573       JIS  B 1051  Sec.  4.2.4 

Rockwell  hardness  of  fasteners 

FA/616       JIS  B1051  Sec.  4.3 

Salt  spray  testing  of  fasteners 

FA/166       ASTM  Bl  17 

Wedge  tensile  strength  of  full-size  threaded  fasteners 

FA/290  ASTM  F606  Sec.  3.5 
FA/575       JIS  B1051  Sec.  4.2.3 

Metallography 

Decarburization  and  case  depth  measurement  in 
fasteners 

FA/645       JISB  1051 

Surface  discontinuities  of  externally  threaded  fasteners 
FA/357      ASTM  F788/788M 

NVLAP  LAB  CODE  200195-0 
Republic  Fastener  Manufacturing 

1300  Rancho  Conejo  Blvd. 
Newbury  Park,  CA  91320-1405 
Contact:  Mr.  Dirk  Deem 
Phone:  805-498-6621 
Fax:  805-498-4250 


Fasteners  &  Metals 

Accreditation  Valid  Through:  March  31,  1999 

NVLAP 

Code  Designation 
Dimensional  Inspection 

Dimensions  of  fasteners  -  bearing  surface  squareness 

FA/633  MIL-N-25027 
FA/911  BPS-N-70 
FA/912      NAS  3350 
FA/913  MIL-N-7873 


NVLAP  1999  DIRECTORY  -  Page  D136 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


FA/914      AMS  7251 

FA/921       Northrop  33 A056 

Internal  thread  parameters  -  system  21 

FA/629  MIL-S-8879 

Internal  thread  parameters  -  system  22 

FA/396  MIL-S-8879 

Surface  texture 

FA/439      ANSI/ASME  B46. 1 

Mechanical  and  Physical  Testing  and  Inspection 

Adhesion  of  metallic  coatings  on  fasteners 
FA/541       QQ-P-4 16  Sec.  4.6.2 
FA/916  BPS-N-70 

Axial  tensile  strength  of full-size  threaded  fasteners 

FA/271  MIL-STD-1312-8 

Elevated  temperature  testing  capability 

FA/895  BPS-N-70 

FA/896  MIL-N-25027 

FA/897      NAS  3350 

Hydrogen  embrittlement  (stress  durability)  of  internally 

threaded  fasteners 

FA/178  MIL-STD-1312-14 

Magnetic  permeability 

FA/214      ASTM  A342  Test  Method  3 

Measurement  of  fastener  coating  thickness  -  beta 

backscatter  method 

FA/889      ASTM  B567 

Measurement  of  fastener  coating  thickness  - 

microscopical  method 

FA/160  ASTMB487 

FA/163  MIL-STD-1312-12 

Microhardness  of  fasteners 

FA/193  MIL-STD-1312-6 

FA/898      NAS  3350 

Permanent  set  test  of  self-locking  nuts 

FA/109  MIL-N-25027 

FA/110      NAS  3350 

FA/890  MIL-N-7873 

Prevailing  torque 

FA/630  MIL-N-25027 

FA/899  BPS-N-70 

FA/900      AMS  7251 

FA/901  MIL-N-7873 

FA/902      NAS  3350 

FA/920      Northrop  33A056 

Proof  load  of  internally  threaded  fasteners  (nuts) 

FA/903      NAS  3350 

FA/917  BPS-N-70 

FA/918  MIL-N-25027 

Push  out  test  of  floating  plate  nuts,  gang  channel  nuts, 
and  anchor  nuts 

FA/116  MIL-N-25027 
FA/891  BPS-N-70 

Reusability  test  of  self-locking  internally  threaded 
fasteners 

FA/123  MIL-N-7873 
FA/124  MIL-N-25027 
FA/125       NAS  3350 
FA/774  BPS-N-70 


FA/892       AMS  7251 

FA/919      Northrop  33 A056 

Rockwell  superficial  hardness  of  fasteners 

FA/205       ASTM  El 8 

FA/209  MIL-STD-1312-6 

Room  temperature  of  three  cycles  test  of floating  plate 

nuts,  gang  channel  nuts  and  anchor 

FA/915       AMS  7251 

Salt  spray  testing  of  fasteners 

FA/166      ASTM  Bl  17 

FA/168  MIL-STD-1312-1 

Torque-out  test 

FA/523  MIL-STD-1312-31 

Water  immersion  method  -  test  for  anodic  surface 

containment  on  corrosion  resistant  fasten 

FA/756       MIL-STD-753  Test  100 

Wrench  torque  test  of  externally  wrenched  nuts  of  spline 

and  hexagon  and  double  hexagon  (1 

FA/141  MIL-N-25027 

FA/142      NAS  3350 

FA/893  BPS-N-70 

FA/894      AMS  7251 

Metallography 

Decarburization  and  case  depth  measurement  in 
fasteners 

FA/904  BPS-N-70 

FA/908      NAS  3350 

Determination  of  grain  size  of fasteners 

FA/905  BPS-N-70 

FA/909      NAS  3350 

Microscopic  examination  of  fasteners  by  etching 
FA/906  BPS-N-70 
FA/910      NAS  3350 

Surface  discontinuities  of  internally  threaded  fasteners 
FA/907  BPS-N-70 
Nondestructive  Inspection 

Liquid  penetrant  inspection  of  fasteners 
FA/521       ASTM  E1417 
Magnetic  particle  inspection  of  fasteners 
FA/485       ASTM  El 444 

NVLAP  LAB  CODE  200196-0 
Belgo-Mineira  Chemical  Laboratory 

Av.  Getulio  Vargas,  No  100 
35.930-900  Joao  Monlevade,  M.G. 
BRAZIL 

Contact:  Mr.  Alexandre  de  Azevedo  Caixeta 
Phone:  055-31-859-1477 
Fax:  055-31-859-1545 
E-Mail:  caixetqa@bms.com.br 

Fasteners  &  Metals 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 
Chemical  Analysis 


NVLAP  1999  DIRECTORY  -  Page  D137 


(See  'How  To  Use  This  Directory*  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Combustion  analysis  for  carbon,  sulfur,  oxygen, 
nitrogen,  and  hydrogen 

FA/455  ASTME1019 
FA/563  ASTME1806 
Optical  emission  spectrochemical  analysis 

FA/457  ASTME415 
FA/555  ASTME1009 
FA/564  ASTME1806 

X-ray  fluorescence  (XRF)  spectrochemical  analysis 

FA/461  ASTME322 
FA/565  ASTME1806 

NVLAP  LAB  CODE  200197-0 
Asakawa  Screw  Co.,  Ltd. 

1261  Nippa-cho,  Kohoku-ku 

Yokohama  223 

JAPAN 

Contact:  Mr.  Tatsuhiko  Asakawa 
Phone:  045-531-1292 
Fax:  045-543-1500 


Fasteners  &  Metals 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 
Dimensional  Inspection 

Dimensions  of  fasteners  -  bearing  surface  squareness 
FA/649  JISB1071 

Dimensions  of  fasteners  -  flange  screw  heads  and  flange 
nuts 

FA/610  JISB1190 

Dimensions  of  fasteners  -  gaging  for  slotted  nuts 

FA/698  JISB1170 

Dimensions  of  fasteners  -  hexagon  and  double  hexagon 

(12  point)  and  spline  sockets 

FA/697  JISB1180 

Dimensions  of  fasteners  -  straightness 

FA/648  JISB1071 

Surface  texture 

FA/650  JISB1071 

Mechanical  and  Physical  Testing  and  Inspection 

Axial  tensile  strength  of  full-size  threaded  fasteners 

FA/574      JIS  B1051  Sec.  4.2.2 

Embrittlement  test  of  washers 

FA/673  JISB1252 

Microhardness  of  fasteners 

FA/620      JIS  Z2244 

Proof  load  of  full-size  externally  threaded  fasteners 

FA/573       JIS  B1051  Sec.  4.2.4 

Proof  load  of  internally  threaded  fasteners  (nuts) 

FA/601       JIS  B 1052 

Rockwell  hardness  of  fasteners 

FA/572      JIS  Z2245 

Rockwell  superficial  hardness  of  fasteners 

FA/699       JIS  Z2245 


Torque-tension  of  full-size  threaded  fasteners 

FA/308  SAEJ174 
Twist  test  of  lock  washers 
FA/678       JIS  B 1251 

Vickers  hardness  -  test  forces  from  9.807  to  11 76  N  (1  to 
120  kgf) 

FA/571  JISZ2244 

Wedge  tensile  strength  of full-size  threaded  fasteners 

FA/575       JIS  B1051  Sec.  4.2.3 

Yield  strength  of  full-size  externally  threaded  fasteners 

FA/686      JIS  B1051  Sec.  4.2.2 

Metallography 

Decarburization  and  case  depth  measurement  in 
fasteners 

FA/645       JIS  B 1051 

Determination  of  grain  size  of fasteners 

FA/700  JISG0551 

Microscopic  examination  of  fasteners  by  etching 

FA/512  ASTME407 

Surface  discontinuities  of  externally  threaded  fasteners 

FA/361  SAEJ123 

Surface  discontinuities  of  internally  threaded  fasteners 

FA/365  SAEJ122 

Nondestructive  Inspection 

Magnetic  particle  inspection  of  fasteners 

FA/701       JIS  G0565  

NVLAP  LAB  CODE  2C0198-0 
IBM  Yamato  EMC  Engineering 

1623-14,  Shimotsuruma 
Yamato  Kanagawa  242 
JAPAN 

Contact:  Mr.  Akihisa  Sakurai 
Phone:  81-462-73-2613 
Fax:  81-462-73-7420 
E-Mail:  akihisa@jp.ibm.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Met/tods 
1 2/FO 1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 


NVLAP  1999  DIRECTORY  -  Page  D138 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  200199-0 
NAWCWPNS  EMI  Lab,  China  Lake/Pt.  Mugu, 
CA 

Commander,  NAWCWPNS  Division 
1  Administration  Circle,  Code  473  MOD 
China  Lake,  CA  93555-6001 
Contact:  Mr.  S.  N.  Tanner 
Phone:  760-939-4669 
Fax:  760-939-1065 

E-Mail:  steve_tanner@imdgw.chinalake.navy.mil 

MIL-STD-462  Test  Methods 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Conducted  Emissions: 

1 2/A0 1       MIL-STD-462  Method  CEO  1 

12/A04       MIL-STD-462  Method  CE02 

1 2/A06       MIL-STD-462  Method  CE03 

12/A08       MIL-STD-462  Method  CE04 

12/A10       MIL-STD-462  Method  CE06 

1 2/A 1 2       MIL-STD-462  Method  CE07 

Conducted  Susceptibility: 

1 2/BO 1       MIL-STD-462  Method  CS0 1 

1 2/B02       MIL-STD-462  Method  CS02 

1 2/B05       MIL-STD-462  Method  CS06 

Radiated  Emissions: 

1 2/DO 1       MIL-STD-462  Method  RE0 1 

1 2/D02       MIL-STD-462  Method  RE02 

Radiated  Susceptibility: 

1 2/EO 1       MIL-STD-462  Method  RS0 1 

1 2/E02       MIL-STD-462  Method  RS02 

12/E03       MIL-STD-462  Method  RS03  (Consult 

laboratory  for  field  strengths  available) 
12/E04       MIL-STD-462  Method  RS03  employing 

RADHAZ  procedures  for  high  level  testing 

(Consult  laboratory  for  field  strengths 

available) 

12/E05       MIL-STD-462  Method  RS05  

NVLAP  LAB  CODE  200200-0 
IBM  RTP  PSG  EMC  Test  Labs 

3039  Cornwallis  Road 

Research  Triangle  Park,  NC  27709-2195 

Contact:  Mr.  Jairo  Pacheco 

Phone:  919-543-3686 

Fax:  919-254-7778 


FCC  Test  Methods 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 


Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200201-0 
Intertek  Testing  Services 

1365  Adams  Court 

Menlo  Park,  CA  94025 

Contact:  Mr.  C.  K.  Li 

Phone:  650-463-2922 

Fax:  650-463-2910 

E-Mail:  ckli@itsqs.com 

URL:  http://www.worldlab.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO  1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
12/F01b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

1 2/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200202-0 
NOVA  Machine  Products 

18001  Sheldon  Road 

Middleburg  Heights,  OH  44130-2471 

Contact:  Mr.  David  Nenstiel 

Phone:  216-267-3200 

Fax:  216-267-8515 

E-Mail:  dnenstiel@nova-nsa.com 

URL:  http://www.lab@nova-nsa.com 

Fasteners  &  Metals 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 
Chemical  Analysis 


NVLAP  1999  DIRECTORY  -  Page  D139 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Optical  emission  spectro chemical  analysis 

FA/457  ASTME415 
FA/459  ASTME1086 
Spot  test  analysis 

FA/748       Alloy  Detector  Mark  II 
Dimensional  Inspection 

Dimensions  of  ISO  grade  A  and  B  fasteners 

FA/738       ISO  4014 

FA/739       ISO  4017 

FA/740      ISO  4032 

Dimensions  of  ISO  grade  C  fasteners 

FA/741       ISO  4016 

FA/742       ISO  40 18 

FA/743       ISO  4034 

Dimensions  of  fasteners  -  bearing  surface  squareness 

FA/745       ANSI  B 18. 2.1 
FA/746  ASME/ANSIB18.2.2 
FA/747       ASME/ANSI  B18.3 

Dimensions  of fasteners  -  flange  screw  heads  and  flange 
nuts 

FA/744      ANSI  B 18. 2.1 

Dimensions  of fasteners  -  gaging  for  slotted  nuts 

FA/417  ANSI/ASMEB18.2.2 

Dimensions  of  fasteners  -  hexagon  and  double  hexagon 

(12  point)  and  spline  sockets 

FA/411       ANSI/ASME  B18.3 

Dimensions  of  fasteners  -  straightness 

FA/423       ANSI/ASME  B 1 8.2. 1 

Dimensions  of  general  purpose  fasteners  and 

high-volume  machine  assembly  fasteners 

FA/403       ANSI/ASME  B  18.1 8. 1M 

FA/404      ANSI/ASME  B 1 8. 1 8.2M 

Dimensions  of  special  purpose  fasteners  and  fasteners  for 

highly  specialized  engineered  ap 

FA/405       ANSI/ASME  B  18.1 8. 3M 

FA/406       ANSI/ASME  B 1 8. 1 8.4M 

External  thread  parameters  -  ISO 

FA/728       ISO  68 

FA/729       ISO  261 

FA/730       ISO  262 

FA/731       ISO  965-1 

FA/732       ISO  965-2 

External  thread  parameters  -  system  21 

FA/379      ANSI/ASME  B1.3M 

External  thread  parameters  -  system  22 

FA/381       ANSI/ASME  B1.3M 

External  thread  parameters  -  system  23 

FA/385       ANSI/ASME  B1.3M 

Internal  thread  parameters  -  ISO 

FA/733       ISO  68 

FA/734       ISO  261 

FA/735       ISO  262 

FA/736       ISO  965-1 

FA/737       ISO  965-2 

Internal  thread  parameters  -  system  21 

FA/391       ANSI/ASME  B1.3M 


Internal  thread  parameters  -  system  22 
FA/393       ANSI/ASME  B 1 .3M 
Internal  thread  parameters  -  system  23 
FA/397      ANSI/ASME  B1.3M 
Surface  texture 

FA/439      ANSI/ASME  B46.1 

Mechanical  and  Physical  Testing  and  Inspection 

Axial  tensile  strength  of full-size  threaded  fasteners 

FA/265       ASTM  A370  Sec.  A3.2. 1 .4 
FA/266       ASTM  F606  Sec.  3.4.1-3.4.3 
FA/273       SAE  J429 
FA/274  SAEJ1216 
FA/687      ISO  6892 

Compression  load  of  compressible-washer-type  direct 
tension  indicators 

FA/312  ASTMF959 

Cone  proof  load  of  internally  threaded  fasteners  (nuts) 

FA/220      ASTM  F606  Sec.  4.3 
Embrittlement  test  of  washers 
FA/313  ASMEB18.21.1 
Hardness  preparation 

FA/482      ASTM  F606 

Hydrogen  embrittlement  (stress  durability)  of  externally 

threaded  fasteners 

FA/176  MIL-STD-1312-5 

Hydrogen  embrittlement  (stress  durability)  of  internally 

threaded  fasteners 

FA/178  MIL-STD-1312-14 

Proof  load  of full-size  externally  threaded  fasteners 

FA/225       ASTM  A370  Sec.  A3.2.1.1-A3.2.1.3 

FA/226       ASTM  F606  Sec.  3.2.1-3.2.3 

FA/229       SAE  J429  Sec.  5.3 

FA/230      SAE  J1216  Sec.  3.3 

Proof  load  of  internally  threaded  fasteners  (nuts) 

FA/235       ASTM  A370  Sec.  A3. 5. 1 

FA/236       ASTM  F606  Sec.  4.2 

FA/241       SAE  J995  Sec.  5.1 

Recovery  test  of  washers 

FA/726      ASME/ANSI  B  18.2 1.1 

Rockwell  hardness  of  fasteners 

FA/196      ASTM  A370  Sec.  18 

FA/197      ASTM  El 8 

FA/200      ISO  6508 

FA/202  SAEJ417 

Rockwell  superficial  hardness  of  fasteners 

FA/205       ASTM  El 8 

FA/206      ASTM  A370  Sec.  18 

FA/210  SAEJ417 

Temper  test  of  lock  washers 

FA/319  ASMEB18.21.1 

Tension  testing  of  machined  specimens  from  externally 
threaded  fasteners 

FA/278       ASTM  A370 
FA/279       ASTM  F606  Sec.  3.6 
FA/283       SAE  J429 
FA/475       ASTM  E8 
FA/580       ISO  6892 


NVLAP  1999  DIRECTORY  -  Page  D140 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Test  for  embrittlement  of  metallic  coated  externally 
threaded  fasteners 
FA/ 179      ASTM  F606  Sec.  7 
FA/724      ASTM  A 143 
Torque-tension  of full-size  threaded  fasteners 
FA/307  MIL-STD-1312-15 
Total  extension  at  fracture  of  externally  threaded 
fasteners 

FA/285       ASTM  F606  Sec.  3.7 
FA/725       ISO  6892 
Twist  test  of  lock  washers 
FA/321  ASMEB18.21.1 

Wedge  tensile  strength  of full-size  threaded  fasteners 

FA/289      ASTM  A370 

FA/290      ASTM  F606  Sec.  3.5 

FA/468       SAE  J429  Sec.  5.5 

FA/469       SAE  J1216  Sec.  3.6 

FA/688       ISO  6892 

Metallography 

Surface  discontinuities  of  externally  threaded  fasteners 
FA/357      ASTM  F788/788M 
FA/359       ISO  6157-1 
FA/360      ISO  6157-3 
FA/361  SAEJ123 

Surface  discontinuities  of  internally  threaded  fasteners 
FA/363       ASTM  F8 12 
FA/365       SAE  J122 

FA/727      ISO  6157-2   

NVLAP  LAB  CODE  200203-0 
Fuji  Buhin  Kogyo  Kabushiki  Kaisha 

47-1  Fujikura-Cho 
Ohta  Gunma  373-8501 
JAPAN 

Contact:  Mr.  Shinji  Kanai 
Phone:  276-31-231  1 
Fax:  276-31-9621 


Fasteners  &  Metals 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 
Dimensional  Inspection 

Internal  thread  parameters  -  system  21 
FA/621  JISB0251 
FA/622      JIS  B0252 
FA/623       JIS  B 1071 

Mechanical  and  Physical  Testing  and  Inspection 

Axial  tensile  strength  of full-size  threaded  fasteners 
FA/574      JIS  B 1051  Sec.  4.2.2 

Measurement  of  fastener  coating  thickness  -  couloinetric 
method 

FA/597      JIS  H8501 
Microhardness  of  fasteners 
FA/620      JIS  Z2244 


Prevailing  torque 

FA/600      JIS  B 1056 

Proof  load  of  internally  threaded  fasteners  (nuts) 

FA/601       JIS  B 1052 

Rockwell  hardness  of  fasteners 

FA/572      JIS  Z2245 

Salt  spray  testing  of  fasteners 

FA/569  JISZ2371 

Wedge  tensile  strength  of  full-size  threaded  fasteners 

FA/575       JIS  B 1051  Sec.  4.2.3  

NVLAP  LAB  CODE  200204-0 
EMSL  Analytical,  Inc. 

19595  NE  10th  Ave.,  Bay  C 
N.  Miami  Beach,  FL  33179 
Contact:  Ms.  Kimberly  A.  Wallace 
Phone:  305-650-0577 
Fax: 305-650-0578 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  200205-0 
Sannohashi  Corporation 

1218  Ohsone 

Yashioshi,  Saitama-ken  340 
JAPAN 

Contact:  Mr.  Takeru  Nagashima 
Phone: 011-81-3-3890-4101 
Fax:  011-81-3-3854-5761 


Fasteners  &  Metals 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

Dimensional  Inspection 

Dimensions  of  general  purpose  fasteners  and 
high-volume  machine  assembly  fasteners 
FA/607      JIS  B 1071 

Mechanical  and  Physical  Testing  and  Inspection 

Axial  tensile  strength  of full-size  threaded  fasteners 
FA/574      JIS  B 1051  Sec.  4.2.2 

Measurement  of  fastener  coating  thickness  -  eddy-current 
method 

FA/618  JISH8501 

Measurement  of  fastener  coating  thickness  -  weight  of 
coating 

FA/619  JISH8501 

Proof  load  of  internally  threaded  fasteners  (nuts) 
FA/601  JISB1052 
Rockwell  hardness  of  fasteners 

FA/572      JIS  Z2245 


NVLAP  1999  DIRECTORY  -  Page  D141 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Wedge  tensile  strength  of full-size  threaded  fasteners 
FA/575       JIS  B1051  Sec.  4.2.3 

NVLAP  LAB  CODE  200207-0 
Kansai  Electronic  Industry  Development  Center, 
Ikoma  Testing  Lab. 
10630  Takayama-cho 
Ikoma  Nara  630-0101 
JAPAN 

Contact:  Mr.  Tadayoshi  Sakabe 
Phone:  0743-78-0283 
Fax:  0743-79-1014 

URL:  http://www.kec.or.jp/ 

FCC  Test  Methods 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
12/F01        FCC  Method  -  47  CFR  Part  15  -  Digital 
Devices 

12/F01a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
12/F01b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200208-0 

Ingersoll  Fasteners 

390  Thomas  Street 
Ingersoll  Ontario  N5C  3K3 
CANADA 

Contact:  Mr.  Alan  Palmer 
Phone:  519-485-4610 
Fax:  519-485-2435 
E-Mail:  IFQA@IVACO.COM 

Fasteners  &  Metals 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Dimensional  Inspection 

Dimensions  of  general  purpose  fasteners  and 
high-volume  machine  assembly  fasteners 
FA/404       ANSI/ASME  B18.18.2M 
External  thread  parameters  -  system  21 
FA/379      ANSI/ASME  B1.3M 
External  thread  parameters  -  system  22 
FA/381       ANSI/ASME  B1.3M 


Internal  thread  parameters  -  system  21 

FA/391       ANSI/ASME  B1.3M 

Mechanical  and  Physical  Testing  and  Inspection 

Axial  tensile  strength  of full-size  threaded  fasteners 

FA/273       SAE  J429 

FA/578       SAE  J1216  Sec.  3.5 

Cone  proof  load  of  internally  threaded  fasteners  (nuts) 

FA/220      ASTM  F606  Sec.  4.3 

Measurement  of  fastener  coating  thickness  -  magnetic 

methods 

FA/ 153  ASTMB499 
Microhardness  of  fasteners 

FA/189  ASTME384 

Proof  load  of full-size  externally  threaded  fasteners 

FA/229       SAE  J429  Sec.  5.3 

FA/577       SAE  J1216  Sec.  3.3 

Proof  load  of  internally  threaded  fasteners  (nuts) 

FA/241       SAE  J995  Sec.  5.1 

Rockwell  hardness  of  fasteners 

FA/ 197       ASTM  El 8 

Rockwell  superficial  hardness  of  fasteners 

FA/205       ASTM  El 8 

Salt  spray  testing  of  fasteners 

FA/166       ASTM  Bl  17 

Tension  testing  of  machined  specimens  from  externally 
threaded  fasteners 

FA/278       ASTM  A370 

Wedge  tensile  strength  of full-size  threaded  fasteners 

FA/468       SAE  J429  Sec.  5.5 
FA/579       SAE  J1216  Sec.  3.6 

Metallography 

Decarburization  and  case  depth  measurement  in 
fasteners 

FA/328  SAEJ121 

Macroscopic  examination  of  fasteners  by  etching 

FA/337  SAEJ1061 

Microscopic  examination  of  fasteners  by  etching 

FA/344  SAEJ121 

Surface  discontinuities  of  externally  threaded  fasteners 

FA/362       SAE  J 1061 

Surface  discontinuities  of  internally  threaded  fasteners 

FA/363       ASTM  F8 12 

NVLAP  LAB  CODE  200210-0 
Rightway  Fasteners,  Inc. 

7945  South  International  Drive 
Columbus,  IN  47201-9329 
Contact:  Mr.  Dennis  Gray 
Phone:  812-342-2700 
Fax:  812-341-3500 


NVLAP  1999  DIRECTORY  -  Page  D142 


(See  'How  To  Use  This  Directory*  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Fasteners  &  Metals 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 
Dimensional  Inspection 

Dimensions  of  fasteners  -  flange  screw  heads  and  flange 
nuts 

FA/690  JISB1071 

Dimensions  of  fasteners  -  hexagon  and  double  hexagon 

(12  point)  and  spline  sockets 

FA/689  JISB1071 

Dimensions  of  fasteners  -  straightness 

FA/648  JISB1071 

Dimensions  of  general  purpose  fasteners  and 
high-volume  machine  assembly  fasteners 
FA/607  JISB1071 

Mechanical  and  Physical  Testing  and  Inspection 

Adhesion  of  metallic  coatings  on  fasteners 
FA/595       JIS  H8504 

Axial  tensile  strength  of full-size  threaded  fasteners 
FA/574      JIS  B 1051  Sec.  4.2.2 

Measurement  of  fastener  coating  thickness  -  weight  of 
coating 

FA/619  JISH8501 

Rockwell  hardness  of  fasteners 

FA/572      JIS  Z2245 

Rockwell  superficial  hardness  of  fasteners 

FA/699      JIS  Z2245 

Salt  spray  testing  of  fasteners 

FA/569  JISZ2371 

Vickers  hardness  -  test  forces  from  9.807  to  11 76  N  (1  to 
120  kgf) 

FA/571  JISZ2244 

Wedge  tensile  strength  of  full-size  threaded  fasteners 
FA/575       JIS  B1051  Sec.  4.2.3 

NVLAP  LAB  CODE  200212-0 
Sundram  Fasteners  Limited  (Inhouse  test 
laboratory) 
Padi 

Chennai  (Madras),  Tamil,  Nadh  600  050 
INDIA 

Contact:  Mr.  Sampathkumar  Moorthy 
Phone:  91-44-852-1870 
Fax:  91-44-853-5435 


Fasteners  &  Metals 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

Dimensional  Inspection 

Dimensions  of  ISO  grade  A  and  B  fasteners 
FA/408       ISO  4759-1 


Dimensions  of  ISO  grade  C  fasteners 

FA/410      ISO  4759-1 

Dimensions  of fasteners  -  flange  screw  heads  and  flange 
nuts 

FA/669  ISO  4161 
FA/670      ISO  4162 

Dimensions  of fasteners  -  gaging  for  slotted  nuts 

FA/980      ISO  4759-2 

Dimensions  of  fasteners  -  straightness 

FA/668       ISO  4759-1 

Dimensions  of  general  purpose  fasteners  and 
high-volume  machine  assembly  fasteners 
FA/665       ISO  4759-1 
External  thread  parameters  -  ISO 

FA/390       ISO  1502 

External  thread  parameters  -  SAE  fastener  with  MJ 
metric  screw  threads 

FA/389       SAE  MAI 566 

FA/661       ISO  4759-1 

FA/662      ISO  1502 

External  thread  parameters  -  system  21 

FA/659      ISO  4759-1 

FA/660      ISO  1502 

Internal  thread  parameters  -  ISO 

FA/402      ISO  1502 

FA/664       ISO  4759-1 

Internal  thread  parameters  -  SAE  fastener  with  MJ 
metric  screw  threads 
FA/979       ISO  4759-1 

Mechanical  and  Physical  Testing  and  Inspection 

Axial  tensile  strength  of full-size  threaded  fasteners 

FA/266       ASTM  F606  Sec.  3.4. 1-3.4.3 

FA/270      ISO  898-1  Sec.  8.2 

FA/273       SAE  J429 

FA/274       SAE  Jl 21 6 

Br  in  ell  hardness  of  fasteners 

FA/466       ISO  6506 

Cone  proof  load  of  internally  threaded  fasteners  (nuts) 

FA/220      ASTM  F606  Sec.  4.3 
FA/221       ASTM  F606M  Sec.  4.3 
FA/223       SAE  J122  Sec.  4.3 
Microhardness  of  fasteners 
FA/657       ASTM  E92 
Prevailing  torque 
FA/217       IFI- 100/1 07 
FA/218       ISO  2320 

Proof  load  of full-size  externally  threaded  fasteners 

FA/226      ASTM  F606  Sec.  3.2.1-3.2.3 

FA/228       ISO  898-1  Sec.  8.4 

FA/229       SAE  J429  Sec.  5.3 

FA/230       SAE  J1216  Sec.  3.3 

FA/467      ASTM  F606M  Sec.  3.2.1-3.2.3 

Proof  load  of  internally  threaded  fasteners  (nuts) 

FA/236      ASTM  F606  Sec.  4.2 

FA/237      ASTM  F606M  Sec.  4.2 

FA/239       ISO  898-2  Sec.  8.1 

FA/240       ISO  898-6  Sec.  8.1 

FA/241       SAE  J995  Sec.  5.1 


NVLAP  1999  DIRECTORY  -  Page  D143 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Rockwell  hardness  of  fasteners 
FA/197  ASTME18 
FA/200      ISO  6508 
Salt  spray  testing  of  fasteners 
FA/166  ASTMB117 

Tension  testing  of  machined  specimens  from  externally 
threaded  fasteners 

FA/279       ASTM  F606  Sec.  3.6 
FA/280      ASTM  F606M  Sec.  3.6 
FA/282       ISO  898-1 
FA/283       SAE  J429 
FA/284       SAE  Jl 216 

Torque-tension  of full-size  threaded  fasteners 
FA/306  IFI-101 
FA/308  SAEJ174 

Total  extension  at  fracture  of  externally  threaded 
fasteners 

FA/285       ASTM  F606  Sec.  3.7 

FA/286       ASTM  F606M  Sec.  3.7 

Vickers  hardness  -  test  forces  from  9.807  to  1 176  N  (1  to 

120  kgf) 

FA/658       ISO  6507-1 

Wedge  tensile  strength  of full-size  threaded  fasteners 

FA/290      ASTM  F606  Sec.  3.5 
FA/291       ASTM  F606M  Sec.  3.5 
FA/294      ISO  898-1  Sec.  8.5 
FA/468       SAE  J429  Sec.  5.5 
FA/469       SAE  J1216  Sec.  3.6 

Yield  strength  of full-size  externally  threaded  fasteners 

FA/298       ASTM  F606  Sec.  3.2.4 
FA/300      ASTM  F606M  Sec.  3.2.4 

Metallography 

Decarburization  and  case  depth  measurement  in 
fasteners 

FA/323       ASTM  El 077 

FA/328  SAEJ121 

FA/329  SAEJ419 

FA/330       SAE  J423 

Determination  of  grain  size  of  fasteners 

FA/331       ASTM  El  12 

FA/333  SAEJ418 

Macroscopic  examination  of  fasteners  by  etching 

FA/334  ISO  6157-1 
FA/335  ISO  6157-3 
FA/336  SAEJ123 

Surface  discontinuities  of  externally  threaded  fasteners 

FA/357       ASTM  F788/788M 
FA/359       ISO  6157-1 
FA/361       SAE  J 123 

Surface  discontinuities  of  internally  threaded  fasteners 

FA/365       SAE  J 122 

FA/865       ASTM  F8 1 2/F8 1 2M 

Nondestructive  Inspection 

Magnetic  particle  inspection  of  fasteners 

FA/374      ASTM  E709 
FA/378       SAE  J420 


NVLAP  LAB  CODE  200213-0 
Aoyama  Fastener  Laboratory 

c/o  Aoyama  Seisakusho 
1-8  Takahashi,  Ohguchi-cho 
Niwa-gun,  Aichi  Prefecture  480-0198 
JAPAN 

Contact:  Mr.  Shinichi  Kondo 
Phone:  0587-95-1  160 
Fax:  0587-95-1939 


Fasteners  &  Metals 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 
Dimensional  Inspection 

Dimensions  of  general  purpose  fasteners  and 
high-volume  machine  assembly  fasteners 
FA/607  JISBI071 
FA/675  JISB1012 
Surface  texture 
FA/650  JISB1071 

Mechanical  and  Physical  Testing  and  Inspection 

Adhesion  of  metallic  coatings  on  fasteners 

FA/595       JIS  H8504 

Axial  tensile  strength  of full-size  threaded  fasteners 

FA/574      JIS  B1051  Sec.  4.2.2 

Measurement  of  fastener  coating  thickness  -  coulometric 
method 

FA/597  JISH8501 

Measurement  of  fastener  coating  thickness  -  eddy-current 
method 

FA/618  JISH8501 

Measurement  of  fastener  coating  thickness  - 
microscopical  method 

FA/640  JISH8501 

Measurement  of  fastener  coating  thickness  -  weight  of 
coating 

FA/619  JISH8501 
Microhardness  of  fasteners 

FA/620      JIS  Z2244 

Proof  load  of  internally  threaded  fasteners  (nuts) 

FA/601  JISB1052 
Rockwell  hardness  of  fasteners 
FA/572      JIS  Z2245 
FA/683       JIS  B 1052 
FA/707      JIS  B 1051  Sec.  4.2.5 
Salt  spray  testing  of  fasteners 
FA/598       JIS  H8502 

Vickers  hardness  -  test  forces  from  9.807  to  11 76  N  (1  to 
120  kgf) 

FA/571  JISZ2244 

FA/643       JIS  B 1051  Sec.  4.2.5 

FA/684      JIS  B 1052 


NVLAP  1999  DIRECTORY  -  Page  D144 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Wedge  tensile  strength  of full-size  threaded  fasteners 

FA/575       JISB 1051  Sec.  4.2.3 

FA/685       JIS  D4604  Sec.  7.7(1) 

Yield  strength  of full-size  externally  threaded  fasteners 

FA/686      JISB  1051  Sec.  4.2.2 

Metallography 

Decarburization  and  case  depth  measurement  in 
fasteners 

FA/645       JISB  1051 

NVLAP  LAB  CODE  200214-0 
Underwriters  Laboratories  Inc. 

2600  N.W.  Lake  Road 
Camas,  WA  98607-8542 
Contact:  Mr.  J.  R.  Beyreis 
Phone:  847-272-8800 
Fax:  847-272-8129 
E-Mail:  beyreisj@ul.com 
URL:  http://www.ul.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/F0 1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

12/F01a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
12/F01b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

1 2/CIS22    IEC/CISPR  22 : 1 993 :  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200215-0 
Sumitomo  Metal  Technology,  Inc.  Kokura 
Division 

1,  Konomi-machi,  Kokurakita-ku 
Kitakyushu  803-0803 
JAPAN 

Contact:  Mr.  Masanao  Nakamura 
Phone:  81-93-581-3289 
Fax:  81-93-561-8099 

E-Mail:  nakamura-msn@aw.sumikin.co.jp 
Fasteners  &  Metals 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 
Chemical  Analysis 


Combustion  analysis  for  carbon,  sulfur,  oxygen, 

nitrogen,  and  hydrogen 

FA/586  JISG1211 

FA/587  JISG1215 

Optical  emission  spectrochemical  analysis 

FA/588  JISG1253 

FA/681       JIS  G 125 8 

Solution  chemical  analysis 

FA/680      JIS  G 1227 

NVLAP  LAB  CODE  200216-0 
Battelle  -  Pacific  Northwest  National  Laboratory 

Battelle  Boulevard  (Mail  Stop  K3-55) 
P.O.  Box  999 

Richland,  WA  99352-4553 

Contact:  Mr.  Jack  J.  Fix 

Phone: 509-375-2512 

Fax:  509-373-0167 

E-Mail:  jack.fix@pnl.gov 

URL:  http://www.pnl.gov/health/health_prot/ 

Ionizing  Radiation  Dosimetry 

Accreditation  Valid  Through:  September  30,  1999 

This  facility  has  been  evaluated  and  deemed  competent  to 
process  the  radiation  dosimeters  listed  below  through 
employing  the  Harshaw  automatic  reader  model  8800  and 
manual  reader  model  6600. 

This  facility  is  accredited  to  process  the  following 
dosimeters  by  virtue  of  actual  demonstration  of  compliance 
with  ANSI  HPS  N  13.1 1-1993  and  ANSI  HPS 
N13. 32-1995  through  testing. 

Harshaw  Card  7776  (15,  15,  6,  15)  in  a  Type  8825  holder 
for  ANSI-N13.il  categories  I,  II,  IIIA,  IIIB,  IV,  VC,  VI, 
VII,  VIII. 

Harshaw  Combo  7777-7666  in  a  8816  and  8825  model 
holder  for  ANSI-N13. 1 1  category  VIII. 

Harshaw  extremity  TLD  XD-740  in  a  finger  ring  holder  for 
ANSI  HPS  N13.32  (NIST  Handbook  150-4,  Table  2) 
categories  I,  II,  IIIA,  IVA,  VC. 

NVLAP  LAB  CODE  200217-0 
Tokin  EMC  Engineering  Co.,  Ltd.  Kawasaki 
Facility 

398,  Shiboguchi  Takatsu-ku 
Kawasaki-city,  Kanagawa  213 
JAPAN 

Contact:  Mr.  Hiro  Shida 
Phone:  81-298-37-2400 
Fax:  81-298-37-2401 


NVLAP  1999  DIRECTORY  -  Page  D145 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


FCC  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200218-0 
Tokin  EMC  Engineering  Co.,  Ltd.  Osaka  Testing 
Laboratory 

49,  Aza-Miyanowaki,  Sakai 
Sanda-city,  Hyogo  669-14 
JAPAN 

Contact:  Mr.  Motoji  Nakai 
Phone:  81-795-69-1290 
Fax:  81-795-69-0079 


FCC  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO  1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  la      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 


NVLAP  LAB  CODE  200219-0 
Tokin  EMC  Engineering  Co.,  Ltd.  Nagoya  Testing 
Laboratory 

1684,  Nishinoda,  Nyugawakami 
Daian-cho,  Inabe-gun,  Mie  51 1-0261 
JAPAN 

Contact:  Mr.  Masa  Hirai 
Phone:  81-594-78-2730 
Fax:  81-594-78-2779 
E-Mail:  GAE01253@nifty.ne.jp 

FCC  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO  1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 

Devices 

1 2/FO  1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22: 1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200220-0 
Korea  Tokin  EMC  Engineering  Co.,  Ltd. 

820-2,  Wolmoon-Ri,  WaBu-up 
Namyangju-si,  Kyunggi-Do 
KOREA 

Contact:  Mr.  Charlies  Park 
Phone:  82-346-576-2204 
Fax:  82-346-576-2205 
E-Mail:  ktemc@united.co.kr 

FCC  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO  1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  la      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 


NVLAP  1999  DIRECTORY  -  Page  D146 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200221-0 
Tokin  EMC  Engineering  Co.,  Ltd.  Tsukuba 
Testing  Laboratory 

28-1,  Aza-Kitahara 
Ohaza-  Hanashimashinden 
Tsukuba-city,  Ibaraki  305 
JAPAN 

Contact:  Mr.  Hira  Shida 
Phone:  81-298-37-2400 
Fax:  81-298-37-2401 


FCC  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

12/F01a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200222-0 
NAWC-Aircraft  Div.  Lakehurst  Electromagnetic 
Interference  Lab. 

Highway  547,  355-2,  Code  48L500B 
Lakehurst,  NJ  08733-5100 
Contact:  Mr.  Richard  Howlett 
Phone:  732-323-2951 
Fax:  732-323-1464 

E-Mail:  howletrm@lakehurst.navy.mil 

MIL-STD-462  Test  Methods 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Conducted  Emissions: 
1 2/A0 1       MIL-STD-462  Method  CEO  1 
1 2/A04       MIL-STD-462  Method  CE02 
1 2/A06       MIL-STD-462  Method  CE03 
12/A12       MIL-STD-462  Method  CE07 


Conducted  Susceptibility: 

1 2/BO 1       MIL-STD-462  Method  CS0 1 

1 2/B02       MIL-STD-462  Method  CS02 

1 2/B05       MIL-STD-462  Method  CS06 

1 2/B08       MIL-STD-462  Method  CS 1 0 

1 2/B09       MIL-STD-462  Method  CS  1 1 

Radiated  Emissions: 

1 2/DO 1       MIL-STD-462  Method  RE0 1 

1 2/D02       MIL-STD-462  Method  RE02 

Radiated  Susceptibility: 

1 2/EO 1       MIL-STD-462  Method  RS0 1 

1 2/E02       MIL-STD-462  Method  RS02 

1 2/E04       MIL-STD-462  Method  RS03  employing 

RADHAZ  procedures  for  high  level  testing 
(Consult  laboratory  for  field  strengths 
available) 

NVLAP  LAB  CODE  200223-0 
Metallic  Material  Laboratory  in  Toyota  Motor 
Co. 

Quality  Div.,  Toyota  Motor  Corporation 
1  Toyota-cho 

Toyota  city  Aichi  471-8571 
JAPAN 

Contact:  Mr.  Toji  Sakota 
Phone:  0565-23-3500 
Fax:  0565-23-5730 


Fasteners  &  Metals 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 
Dimensional  Inspection 

Dimensions  of fasteners  -  flange  screw  heads  and  flange 
nuts 

FA/690  JISB1071 

Dimensions  of  fasteners  -  hexagon  and  double  hexagon 

(12  point)  and  spline  sockets 

FA/689  JISB1071 

Dimensions  of  fasteners  -  straightness 

FA/648  JISB1071 

Dimensions  of  general  purpose  fasteners  and 

high-volume  machine  assembly  fasteners 

FA/607  JISB1071 

External  thread  parameters  -  system  21 

FA/647  JISB1071 

Internal  thread  parameters  -  system  21 

FA/623  JISB1071 

Mechanical  and  Physical  Testing  and  Inspection 

Axial  tensile  strength  of  full-size  threaded  fasteners 

FA/574      JIS  B 1051  Sec.  4.2.2 

Measurement  of  fastener  coating  thickness  -  magnetic 

methods 

FA/596  JISH8501 


NVLAP  1999  DIRECTORY  -  Page  D147 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Measurement  of  fastener  coating  thickness  - 
microscopical  met  hod 
FA/640  JISH8501 
Microhardness  of  fasteners 
FA/620      JIS  Z2244 

Proof  load  of  internally  threaded  fasteners  (nuts) 

FA/601       JIS  B 105 2 

Salt  spray  testing  of  fasteners 

FA/598       JIS  H8502 

Vickers  hardness  -  test  forces  from  9.807  to  11 76  N  (1  to 

120  kgf) 

FA/571  JISZ2244 

FA/643       JIS  B1051  Sec.  4.2.5 

FA/684       JIS  B 1052 

Wedge  tensile  strength  of full-size  threaded  fasteners 
FA/575       JIS  B1051  Sec.  4.2.3 
Metallography 

Decarburization  and  case  depth  measurement  in 
fasteners 

FA/645       JIS  B 1051 

NVLAP  LAB  CODE  200224-0 
Northwestern  Steel  and  Wire  Company 

121  Wallace  Street 
P.O.  Box  618 
Sterling,  IL  61081 
Contact:  Mr.  Robert  C.  Olson 
Phone:  815-625-2500 

Fax:  815-625-0227 


Fasteners  &  Metals 

Accreditation  Valid  Through:  September  30,  1999 

NVLAP 

Code  Designation 
Chemical  Analysis 

Optical  emission  spectrochemical  analysis 

FA/457  ASTME415 

NVLAP  LAB  CODE  200225-0 
J.W.  Mfg.  DBA  Van  Petty  Mfg. 

25 1 7  Azurite  Circle 
Newbury  Park,  C A  91320 
Contact:  Mr.  Robert  Bucholtz 
Phone:  805-498-4594 
Fax:  805-458-1021 


Fasteners  &  Metals 

Accreditation  Valid  Through:  March  31,  1999 
NVLAP 

Code  Designation 
Dimensional  Inspection 

Dimensions  of  fasteners  -  hexagon  and  double  hexagon 
(12  point)  and  spline  sockets 

FA/411       ANSI/ASME  B18.3 


Dimensions  of  special  purpose  fasteners  and  fasteners  for 

highly  specialized  engineered  ap 

FA/405       ANSI/ASME  B 1 8. 1 8.3M 

External  thread  parameters  -  system  22 

FA/382  FED-STD-H28/20 

Surface  texture 

FA/439       ANSI/ASME  B46.1 

Mechanical  and  Physical  Testing  and  Inspection 

Double  shear  of  externally  threaded  fasteners 

FA/257  MIL-STD-1312-13 

Rockwell  hardness  of  fasteners 

FA/201  MIL-STD-1312-6 

Stress  rupture  of  fasteners 

FA/262  MIL-STD-1312-10 

Wedge  tensile  strength  of full-size  threaded  fasteners 

FA/290      ASTM  F606  Sec.  3.5 

FA/295  MIL-STD-1312-8 

Metallography 

Decarburization  and  case  depth  measurement  in 
fasteners 

FA/323       ASTM  El 077 
Determination  of  grain  size  of fasteners 

FA/331       ASTM  El  12 
FA/550       ASTM  E3 

Macroscopic  examination  of  fasteners  by  etching 

FA/511  ASTME340 
FA/551  ASTME3 

Microscopic  examination  of  fasteners  by  etching 

FA/512  ASTME407 
FA/552      ASTM  E3 

Nondestructive  Inspection 

Liquid  penetrant  inspection  of  fasteners 

FA/527      ASTM  E1417 

Magnetic  particle  inspection  of  fasteners 

FA/485       ASTM  El 444  

NVLAP  LAB  CODE  200226-0 
Sugiura  Seisakusho  Co.,  Ltd. 

22,  Miyakoshi,  Terazu-cho 
Nishio  Aichi  444-03 
JAPAN 

Contact:  Mr.  Shigemitsu  Shibata 

Phone:  0563-59-0728 

Fax:  0563-59-0744 

E-Mail:  sscshiba@mx01.tns.or.jp 

Fasteners  &  Metals 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 
Dimensional  Inspection 

Dimensions  of fasteners  -  gaging  for  slotted  nuts 

FA/698  JIS  Bl  170 
FA/721       JIS  B 1071 


NVLAP  1999  DIRECTORY  -  Page  D148 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


External  thread  parameters  -  ISO 

FA/676  JISB1071 

Internal  thread  parameters  -  ISO 

FA/720  JISB1071 

Mechanical  and  Physical  Testing  and  Inspection 

Axial  tensile  strength  of  full-size  threaded  fasteners 

FA/574      JISB 1051  Sec.  4.2.2 

Measurement  of  fastener  coating  thickness  -  X-ray 

methods 

FA/641  JISH8501 
Prevailing  torque 

FA/600      JISB  1056 

Proof  load  of  internally  threaded  fasteners  (nuts) 

FA/601  JISB1052 

Rockwell  hardness  of  fasteners 

FA/572      JIS  Z2245 

Salt  spray  testing  of  fasteners 

FA/598      JIS  H8502 

Vickers  hardness  -  test  forces  from  9.807  to  1176  N  (1  to 
120  kgf) 

FA/571  JISZ2244 

FA/643       JISB  1051  Sec.  4.2.5 

FA/684      JISB  1052 

Wedge  tensile  strength  of full-size  threaded  fasteners 
FA/575       JIS  B1051  Sec.  4.2.3 
Metallography 

Surface  discontinuities  of  externally  threaded  fasteners 
FA/603       JISB  1043 
FA/646      JISB  1041 

Surface  discontinuities  of  internally  threaded  fasteners 
FA/604      JISB  1042 

NVLAP  LAB  CODE  200227-0 
Owari  Precise  Products  Co.,  Ltd. 

148  2-chome,  Yada-cho,  Higashi-ku 

Nagoya  461-8678 

JAPAN 

Contact:  Mr.  Kouichi  Furuichi 
Phone:  052-721-7131 
Fax:  052-723-2966 


Fasteners  &  Metals 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 
Dimensional  Inspection 

Dimensions  of  general  purpose  fasteners  and 
high-volume  machine  assembly  fasteners 
FA/607      JISB  1071 
FA/675  JISB1012 
Surface  texture 
FA/650      JISB  1071 

Mechanical  and  Physical  Testing  and  Inspection 


Axial  tensile  strength  of full-size  threaded  fasteners 

FA/574      JIS  B1051  Sec.  4.2.2 

Measurement  of  fastener  coating  thickness  -  X-ray 

methods 

FA/64!  JISH8501 

Measurement  of  fastener  coating  thickness  - 
microscopical  method 

FA/640      JIS  H8501 

Measurement  of  fastener  coating  thickness  -  weight  of 
coating 

FA/619  JISH8501 
Microhardness  of  fasteners 
FA/620       JIS  Z2244 
Prevailing  torque 
FA/600      JISB  1056 

Proof  load  of full-size  externally  threaded  fasteners 

FA/573       JIS  B1051  Sec.  4.2.4 

Proof  load  of  internally  threaded  fasteners  (nuts) 

FA/601       JISB  1052 

FA/713       JISB  1056 

Rockwell  hardness  of  fasteners 

FA/572      JIS  Z2245 

Salt  spray  testing  of  fasteners 

FA/569  JISZ2371 

Vickers  hardness  -  test  forces  from  9.807  to  1176  N  (1  to 
120  kgf) 

FA/571  JISZ2244 

Wedge  tensile  strength  of full-size  threaded  fasteners 

FA/575       JIS  B1051  Sec.  4.2.3 

Yield  strength  of full-size  externally  threaded  fasteners 

FA/714  JISZ2241 

Metallography 

Decarburization  and  case  depth  measurement  in 
fasteners 

FA/645       JISB  1051 

Surface  discontinuities  of  externally  threaded  fasteners 
FA/603       JISB  1043 
FA/646      JISB  1041 

Surface  discontinuities  of  internally  threaded  fasteners 
FA/604      JISB  1042 

NVLAP  LAB  CODE  200228-0 
Oak  Ridge  National  Laboratory 

Bethel  Valley  Road 

P.O.  Box  2008 

Oak  Ridge,  TN  37831-6292 

Contact:  Mr.  Brian  A.  Jerome 

Phone:  423-574-6167 

Fax:  423-576-5070 

E-Mail:  jeromeba@ornl.gov 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  December  31,  1999 


NVLAP  1999  DIRECTORY  -  Page  D149 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  200229-0 
Minebea  Co.,  Ltd.  Fujisawa  Manufacturing  Unit 

1-1-1  Katase 

Fujisawa,  Kanagawa  251 

JAPAN 

Contact:  Mr.  Yukio  Shimada 
Phone:  0466-23-2137 
Fax:  0466-27-6449 


Fasteners  &  Metals 

Accreditation  Valid  Through:  March  31,  1999 
NVLAP 

Code  Designation 
Chemical  Analysis 

Combustion  analysis  for  carbon,  sulfur,  oxygen, 
nitrogen,  and  hydrogen 

FA/472       ASTM  E1447 

Dimensional  Inspection 

Dimensions  of  fasteners  -  bearing  surface  squareness 
FA/649  JISB1071 

Dimensions  of  fasteners  -  hexagon  and  double  hexagon 

(12  point)  and  spline  sockets 

FA/539       SAE  AS  870 

FA/790       SBAC  RS680 

Dimensions  of  fasteners  -  straightness 

FA/648  JISB1071 

Dimensions  of  general  purpose  fasteners  and 

high-volume  machine  assembly  fasteners 

FA/607  JISB1071 

FA/791  NAS527 

External  thread  parameters  -  system  21 

FA/379  ANSI/ASMEB1.3M 

FA/380  FED-STD-H28/20A 

External  thread  parameters  -  system  22 

FA/381  ANSI/ASMEB1.3M 

FA/382  FED-STD-H28/20A 

External  thread  parameters  -  system  23 

FA/385       ANSI/ASME  B1.3M 

FA/386  FED-STD-H28/20A 

Surface  texture 

FA/439       ANSI/ASME  B46.1 
FA/650  JISB1071 
FA/771       BS  11 34,  Parti 

Mechanical  and  Physical  Testing  and  Inspection 

Axial  tensile  strength  of  full-size  threaded  fasteners 

FA/266       ASTM  F606  Sec.  3.4.1-3.4.3 

FA/271  MIL-STD-1312-8 

FA/574      JISB1051  Sec.  4.2.2 

Double  shear  of  externally  threaded  fasteners 

FA/257  MIL-STD-1312-13 

Elevated  temperature  testing  capability 

FA/505  MIL-STD-1312-18 

Fatigue  of  full-size  threaded  fasteners 

FA/183       MIL-STD-1312-1 1 


Hardness  preparation 

FA/482       ASTM  F606 
Head  soundness  testing 
FA/615       JISB 1051  Sec.  4.2.6 
Humidity  testing  of  fasteners 
FA/170  QQ-P-35 

Measurement  of  fastener  coating  thickness  -  dimensional 

change  method 

FA/495       MIL-STD-1312-1 2 

Measurement  of  fastener  coating  thickness  -  eddy-current 
method 

FA/618  JISH8501 

Measurement  of  fastener  coating  thickness  - 
microscopical  method 
FA/163  MIL-STD-1312-12 
FA/640  JISH8501 

Measurement  of  fastener  coating  thickness  -  weight  of 
coating 

FA/619  JISH8501 

Microhardness  of  fasteners 

FA/193  MIL-STD-1312-6 

FA/620      JIS  Z2244 

FA/642       JIS  B1051  Sec.  4.2.5 

Proof  load  of  full-size  externally  threaded  fasteners 

FA/573       JIS  B1051  Sec.  4.2.4 

Recess  strength  test  in  both  the  installation  and  removal 
directions 

FA/476  MIL-STD-1312-25 

Rockwell  hardness  of  fasteners 

FA/197       ASTM  El 8 

FA/201  MIL-STD-1312-6 

FA/572      JIS  Z2245 

FA/707      JISB  1051  Sec.  4.2.5 

FA/765       BS  EN  10109-1 

Rockwell  superficial  hardness  of  fasteners 

FA/205       ASTM  El 8 

FA/209  MIL-STD-1312-6 

FA/766       BS  EN  10109-1 

Salt  spray  testing  of  fasteners 

FA/166       ASTM  Bl  17 

FA/168  MIL-STD-1312-1 

FA/569  JISZ2371 

Stress  rupture  of  fasteners 

FA/260  ASTME139 

FA/767      BS4A4,Part  l,Sec3 

Tension  testing  of  machined  specimens  from  externally 

threaded  fasteners 

FA/581       JIS  B1051  Sec.  4.2.1 

FA/582  JISZ2241 

FA/768       BS4A4,Part  l,Sec  1 

Wedge  tensile  strength  of full-size  threaded  fasteners 

FA/290      ASTM  F606  Sec.  3.5 

FA/575       JIS  B1051  Sec.  4.2.3 

Metallography 

Decarburization  and  case  depth  measurement  in 
fasteners 

FA/645       JISB  1051 
FA/692  MIL-STD-1312-6 


NVLAP  1999  DIRECTORY  -  Page  D150 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Determination  of  grain  size  of  fasteners 
FA/331  ASTME112 

Macroscopic  examination  of  fasteners  by  etching 

FA/511  ASTME340 

FA/769      AMS  7477 

FA/780      SB  AC  TS21 

FA/782      SBAC  TS22 

FA/783       SBAC  TS23 

FA/786      SBAC  TS24 

FA/787      SBAC  TS25 

Microscopic  examination  of  fasteners  by  etching 

FA/512  ASTME407 

FA/770      AMS  7477 

FA/781  SBACTS21 

FA/784      SBAC  TS22 

FA/785       SBAC  TS23 

FA/788       SBAC  TS24 

FA/789       SBAC  TS25 

Surface  discontinuities  of  externally  threaded  fasteners 
FA/603  JISB1043 
FA/646  JISB1041 

Nondestructive  Inspection 

Liquid  penetrant  inspection  of fasteners 

FA/371  MIL-STD-6866 

FA/527  ASTME1417 

Magnetic  particle  inspection  of  fasteners 

FA/377  MIL-STD-1949 

FA/485  ASTME1444  

NVLAP  LAB  CODE  200230-0 
Wolverine  Plating  Corp. 

29456  Groesbeck  Highway 
Roseville,MI  48066-1943 
Contact:  Mr.  Kenneth  Wrobel 
Phone:  810-771-5000 
Fax:  810-771-5830 
E-Mail:  wolvpltg@aol.com 

Fasteners  &  Metals 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

Mechanical  and  Physical  Testing  and  Inspection 

Adhesion  of  metallic  coatings  on  fasteners 
FA/ 143  ASTMB571 

Measurement  of  fastener  coating  thickness  -  X-ray 
methods 

FA/556      ASTM  B568 
Salt  spray  testing  of  fasteners 
FA/166      ASTM  Bl  17 


NVLAP  LAB  CODE  200231-0 

U.S.  EPA 

P.O.  Box  98517 

Las  Vegas,  NV  89193-8517 

Contact:  Mr.  Christopher  Fontana 

Phone:  702-798-2429 

Fax:  702-733-8013 

E-Mail:  fontana-chris@wpmail.las.wpa.gov 

Ionizing  Radiation  Dosimetry 

Accreditation  Valid  Through:  December  31,  1999 

This  facility  has  been  evaluated  and  deemed  competent  to 
process  the  radiation  dosimeter  listed  below  through 
employing  the  Panasonic  automatic  reader  model  UD710A. 

This  facility  is  accredited  to  process  the  following 
dosimeter  by  virtue  of  actual  demonstration  of  compliance 
with  ANSI  HPS  N13. 11-1993. 

Panasonic  TLD  model  UD802AT  in  a  UD874  holder  for 
ANSI-N1 3. 1 1  categories  I,  II,  III  A,  IV,  VC,  VI,  VII. 

NVLAP  LAB  CODE  200232-0 

LA  Testing 

159  Pasadena  Avenue 
S.  Pasadena,  CA  91030 
Contact:  Ms.  Cristina  E.  Tabatt 
Phone:  323-254-9960 
Fax:  323-254-9982 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  200233-0 
SGI  EMC  Laboratories 

P.O.  Box  7311 

201 1  N.  Shoreline  Blvd.,  MS  946 

Mountain  View,  CA  94039 

Contact:  Mr.  David  M.  Hanttula 

Phone:  650-933-1071 

Fax:  650-932-0250 

E-Mail:  hanttula@engr.sgi.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 


NVLAP  1999  DIRECTORY  -  Page  D151 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


12/F01a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
12/F01b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200234-0 
International  Standards  Laboratory 

21,  Alley  37,  Lane  122,  Sec.  2 

Hsiwan  Road 

Hsichih  Chen,  Taipei  221 

TAIWAN 

Contact:  Mr.  Jammy  Chen 
Phone:  886-2-2646-2550 
Fax:  886-2-2646-4641 


FCC  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  la      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200236-0 
Accredited  Environmental  Technologies,  Inc. 

State  Road  1426 
Leland,NC  28451 
Contact:  Mr.  Peter  J.  Burke 
Phone:  910-371-4620 
Fax:  910-371-4908 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  September  30,  1999 


NVLAP  LAB  CODE  200237-0 
Compliance  Test  Laboratories,  Inc. 

137  Airport  Road 
P.O.  Box  120 
Liberty,  SC  29657 
Contact:  Mr.  Pryor  McGinnis 
Phone:  864-843-1604 
Fax:  864-843-1812 
E-Mail:  ctl@prodigy.net 

FCC  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 

NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T50  AS/NZS  3260 
12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO  1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/F0 1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
12/F01b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200239-0 

Meidoh  Laboratory 

4-5  Sangen-Cho 
Toyota,  Aichi  471-0037 
JAPAN 

Contact:  Mr.  Satoki  Akiba 
Phone:  0565-31-0330 
Fax:  0565-31-2153 


Fasteners  &  Metals 

Accreditation  Valid  Through:  March  31,  1999 

NVLAP 

Code  Designation 

Dimensional  Inspection 

External  thread  parameters  -  system  21 
FA/647  JISB1071 
Internal  thread  parameters  -  system  21 
FA/623  JISB1071 

Mechanical  and  Physical  Testing  and  Inspection 

Axial  tensile  strength  of full-size  threaded  fasteners 
FA/574      JISB 1051  Sec.  4.2.2 


NVLAP  1999  DIRECTORY  -  Page  D152 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Measurement  of  fastener  coating  thickness  -  magnetic 
methods 

FA/596  JISH8501 

Measurement  of  fastener  coating  thickness  - 

microscopical  method 

FA/640  JISH8501 

Microhardness  of  fasteners 

FA/620      JIS  Z2244 

FA/642      JIS  B 1051  Sec.  4.2.5 

Proof  load  of  internally  threaded  fasteners  (nuts) 

FA/601       JIS  B 1052 

Salt  spray  testing  of  fasteners 

FA/598       JIS  H8502 

Vickers  hardness  -  test  forces  from  9.807  to  1176  N  (1  to 
120  kgf) 

FA/571  JISZ2244 
FA/684  JIS  B 1052 
FA/952  JISZ2251 

Wedge  tensile  strength  of full-size  threaded  fasteners 

FA/575       JIS  B 1051  Sec.  4.2.3  

NVLAP  LAB  CODE  200240-0 
CAM  Environmental  Services,  Inc. 

312  South  Richey  Street 

Pasadena,  TX  77506-1059 

Contact:  Ms.  Julia  A.  Terrell 

Phone:  713-475-9003 

Fax:  713-472-2117 

E-Mail:  camenviro@earthlink.net 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  200242-0 
Topura  Co.,  Ltd.  Osaka 

4-10-2  Kisabe-Minami 
Katano,  Osaka  576-0035 
JAPAN 

Contact:  Mr.  Katsuzo  Fujihira 
Phone:  0463-82-4179 
Fax:  0463-82-6169 


Fasteners  &  Metals 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

Dimensional  Inspection 

Dimensions  of  general  purpose  fasteners  and 
high-volume  machine  assembly  fasteners 

FA/607      JIS  B 1071 
FA/675       JIS  B 101 2 
FA/682  JASOF116 
External  thread  parameters  -  ISO 
FA/676      JIS  B 1071 

Mechanical  and  Physical  Testing  and  Inspection 


Axial  tensile  strength  of full-size  threaded  fasteners 

FA/574      JIS  B 1051  Sec.  4.2.2 

FA/672      JIS  B 1054 

Embrittlement  test  of  washers 

FA/673       JIS  B 1252 

Head  soundness  testing 

FA/615       JIS  B1051  Sec.  4.2.6 

Measurement  of  fastener  coating  thickness  -  eddy-current 
method 

FA/618  JISH8501 

Measurement  of  fastener  coating  thickness  -  weight  of 
coating 

FA/619  JISH8501 
Microhardness  of  fasteners 

FA/620      JIS  Z2244 

Proof  load  of full-size  externally  threaded  fasteners 

FA/573       JIS  B1051  Sec.  4.2.4 

Recovery  test  of  washers 

FA/674      JIS  B 1252 

FA/677      JIS  B 1251 

Rockwell  hardness  of  fasteners 

FA/707      JIS  B 1051  Sec.  4.2.5 

Salt  spray  testing  of  fasteners 

FA/569  JISZ2371 

FA/598      JIS  H8502 

Twist  test  of  lock  washers 

FA/678      JIS  B 1251 

Wedge  tensile  strength  of full-size  threaded  fasteners 
FA/575       JIS  B1051  Sec.  4.2.3 
Metallography 

Decarburization  and  case  depth  measurement  in 
fasteners 

FA/645       JIS  B 1051 

Surface  discontinuities  of  externally  threaded  fasteners 

FA/603  JIS  B 1043 
FA/646       JIS  B 1041 

NVLAP  LAB  CODE  200243-0 
Topura  Co.,  Ltd.  Tokai 

2158-96  Kaizan,  Aza  Shiobara  Shinden 
Hamaoka-cho 

Ogasagun,Shizuoka  437-1614 
JAPAN 

Contact:  Mr.  Katsuzo  Fujihira 
Phone:  0463-82-4179 
Fax:  0463-82-6169 


Fasteners  &  Metals 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

Dimensional  Inspection 

Dimensions  of  general  purpose  fasteners  and 
high-volume  machine  assembly  fasteners 

FA/607  JIS  B 1071 
FA/675       JIS  Bl 012 


NVLAP  1999  DIRECTORY  -  Page  D153 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


FA/682  JASOF116 
External  thread  parameters  -  ISO 

FA/676  JISB1071 

Mechanical  and  Physical  Testing  and  Inspection 

Axial  tensile  strength  of  full-size  threaded  fasteners 

FA/574      JIS  B 1051  Sec.  4.2.2 

FA/672      JIS  B 1054 

Embrittlement  test  of  washers 

FA/673       JIS  B 125  2 

Head  soundness  testing 

FA/615       JIS  B 1051  Sec.  4.2.6 

Measurement  of  fastener  coating  thickness  -  eddy-current 
method 

FA/618  JISH8501 

Measurement  of  fastener  coating  thickness  -  weight  of 
coating 

FA/619  J1SH8501 
Microhardness  of  fasteners 
FA/620      JIS  Z2244 

Proof  load  of full-size  externally  threaded  fasteners 

FA/573       JIS  B 1051  Sec.  4.2.4 

Recovery  test  of  washers 

FA/674      JIS  B 1252 

FA/677      JIS  B 1251 

Rockwell  hardness  of  fasteners 

FA/707       JIS  B 1051  Sec.  4.2.5 

Salt  spray  testing  of  fasteners 

FA/569  JISZ2371 

FA/598       JIS  H8502 

Twist  test  of  lock  washers 

FA/678       JIS  B 1251 

Wedge  tensile  strength  of full-size  threaded  fasteners 
FA/575       JIS  B 1051  Sec.  4.2.3 
Metallography 

Decarburization  and  case  depth  measurement  in 
fasteners 

FA/645       JIS  B 1051 

Surface  discontinuities  of  externally  threaded  fasteners 
FA/603       JIS  B 1043 

FA/646      JIS  B 1041  

NVLAP  LAB  CODE  200244-0 
Oak  Ridge  National  Laboratory  Electric 
Machinery  Center 

P.O.  Box  2009 
Oak  Ridge,  TN  37831-8038 
Contact:  Mr.  John  Kueck 
Phone:  423-576-4454 
Fax:  423-576-0493 
E-Mail:  KU5@ornl.gov 

Efficiency  of  Electric  Motors 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 
24/M01      IEEE  112,  Method  B 


NVLAP  LAB  CODE  200245-0 

RheinTexas,  Inc. 

1701  East  Piano  Parkway,  Suite  150 
Piano,  TX  75074-8127 
Contact:  Mr.  Murrell  Waldron 
Phone:  972-509-2566 
Fax:  972-509-0073 


FCC  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  la      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200246-0 
Underwriters  Laboratories,  Inc. 

1 2  Laboratory  Drive 

Research  Triangle  Park,  NC  27709 

Contact:  Mr.  James  R.  Beyreis 

Phone:  847-272-8800 

Fax:  847-272-8129 

E-Mail:  beyreisj@ul.com 

URL:  http://www.ul.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 

1 2/FO  1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  la      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22: 1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 


NVLAP  1999  DIRECTORY  -  Page  D154 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  200247-0 
EMSL  Analytical,  Inc. 

4037  E.  Independence  Blvd.,  Suite  630 

Charlotte,  NC  28205 

Contact:  Mr.  Ronald  K.  Mahoney 

Phone:  704-567-1521 

Fax:  704-567-1394 

URL:  http://www.emsl.com/ 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  200248-0 
Orfield  Laboratories,  Inc. 

2709  E.  25th  Street 
Minneapolis,  MN  55406 
Contact:  Mr.  Steven  J.  Orfield 
Phone: 612-721-2455 
Fax:  612-721-2457 


Acoustical  Testing  Services 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

08/P03  ASTM  C423  (ISO  354) 

08/P06  ASTM  E90  (ISO  140,  Part  3) 

08/P10  ANSI  S12.31  (ISO  3741) 

08/P21  ISO  3745 

08/P30  ASTM  E1408 

08/P31  ASTM  E3  3  6 

08/P32  ASTM  El 007 

08/P37  ASTM  E966  

NVLAP  LAB  CODE  200249-0 
Quest  MicroAnalytics,  Inc. 

2530  Electronic  Lane,  Suite  712 
Dallas,  TX  75220-1229 
Contact:  Ms.  Jennifer  Jaber 
Phone:  214-351-4441 
Fax:  214-351-4487 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  200250-0 

ATC  Associates  Inc. 

8989  Herrmann  Drive 

Columbia,  MD  21045-4710 

Contact:  Dr.  Bharatha  Lakshmi 

Phone:  410-381-0232 

Fax: 410-381-8908 

E-Mail:  lakshmi9@atc-enviro.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  200251-0 
Storagtek  Open  Area  Test  Site 

2270  So.  88th  Street,  MS-9172 
Louisville,  CO  80028-9172 
Contact:  Mr.  Robert  B.  Reinert 
Phone:  303-673-6256 
Fax:  303-661-6717 

E-Mail:  reinerb@louisville.stortek.com 
FCC  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 
12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

12/F01a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200252-0 
Underwriters  Laboratories 

1655  Scott  Blvd. 
Santa  Clara,  CA  95050 
Contact:  Mr.  Rick  A.  Titus 
Phone:  847-272-8800  x43281 
Fax:  847-509-6219 
E-Mail:  titusr@ul.com 
URL:  http://www.ul.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 


NVLAP  1999  DIRECTORY  -  Page  D155 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


AUSTEL  Technical  Standards  as  determined  under  the 
Telecommunications  Act  of  1991 

12/T41  TS-001 
12/T42  TS-002 
12/T44  TS-004 
12/T45  TS-006 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T50  AS/NZS  3260 
12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 
1 2/TO 1       Terminal  Equipment  Network  Protection 

Standards,  FCC  Method  -  47  CFR  Part  68  - 

Analog  and  Digital 
1 2/TO  la      68.302  (Par.  c,d,e,f)  Environmental  simulation; 

68.304  Leakage  current  limit.;  68.306 

Hazardous  voltage  limit.;  68.308  Signal  power 

limit.;  68.310  Longitudinal  balance  limit.; 

68.312  On-hook  impedance  limit.;  68.314 

Billing  protection 
1 2/TO  lb     68.316  Hearing  Aid  Compatibility:  technical 

standards 

12/T01c      68.302  Environmental  simulation  (Par.  a,b) 
International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200253-0 

CBS  Fasteners,  Inc. 

1345  N.  Brasher  Street 
Anaheim,  CA  92807 
Contact:  Mr.  Bill  Sisler 
Phone:  714-779-6368 
Fax:  714-779-0934 


Fasteners  &  Metals 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 
Dimensional  Inspection 

Dimensions  of  fasteners  -  hexagon  and  double  hexagon 
(12  point)  and  spline  sockets 
FA/411       ANSI/ASME  B18.3 
Dimensions  of  fasteners  -  straightness 
FA/423       ANSI/ASME  B 1 8.2. 1 
Dimensions  of  general  purpose  fasteners  and 
high-volume  machine  assembly  fasteners 
FA/404      ANSI/ASME  B 1 8. 1 8.2M 


External  thread  parameters  -  system  22 
FA/382  FED-STD-H28/20 
Surface  texture 

FA/439      ANSI/ASME  B46.1 

Mechanical  and  Physical  Testing  and  Inspection 

Axial  tensile  strength  of full-size  threaded  fasteners 
FA/271  MIL-STD-1312-8 
Double  shear  of  externally  threaded  fasteners 
FA/257  MIL-STD-1312-13 

Hydrogen  embrittlement  (stress  durability)  of  externally 

threaded  fasteners 

FA/176  MIL-STD-1312-5 

Magnetic  permeability 

FA/2 1 4      ASTM  A342  Test  Method  3 

Measurement  of  fastener  coating  thickness  -  dimensional 

change  method 

FA/495  MIL-STD-1312-12 

Measurement  of  fastener  coating  thickness  - 

microscopical  method 

FA/ 163  MIL-STD-1312-12 

Microhardness  of  fasteners 

FA/193  MIL-STD-1312-6 

Recess  strength  test  in  both  the  installation  and  removal 
directions 

FA/476  MIL-STD-1312-25 

Rockwell  hardness  of  fasteners 

FA/201  MIL-STD-1312-6 

Rockwell  superficial  hardness  of  fasteners 

FA/209  MIL-STD-1312-6 

Single  shear  of  externally  threaded  fasteners 

FA/256  MIL-STD-1312-20 

Vickers  hardness  -  test  forces  from  9.807  to  1176  N (1  to 
120  kgf) 

FA/671  MIL-STD-1312-6 

Wedge  tensile  strength  of  full-size  threaded  fasteners 

FA/295  MIL-STD-1312-8 

Metallography 

Decarburization  and  case  depth  measurement  in 
fasteners 

FA/330       SAE  J423 
FA/483       ASTM  A574  Sec.  12 
Determination  of  grain  size  of fasteners 
FA/638       ASTM  El  12 

Macroscopic  examination  of  fasteners  by  etching 

FA/5 1 1       ASTM  E340 

FA/651       ASTM  F788/788M 

Microscopic  examination  of  fasteners  by  etching 

FA/341       ASTM  El 077 

FA/345       ASTM  F788/788M 

FA/351       ASTM  El  12 

FA/512  ASTME407 

FA/552       ASTM  E3 

FA/679      ASTM  A5  74 

Surface  discontinuities  of  externally  threaded  fasteners 

FA/357      ASTM  F788/788M 


NVLAP  1999  DIRECTORY  -  Page  D156 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  200254-0 
Vermont  Fasteners  Manufacturing 

50  Jonergin  Drive 
P.O.  Box  50 

Swanton,  VT  05488-0050 
Contact:  Mr.  Peter  F.  Kasper 
Phone:  802-868-3663 
Fax:  802-868-2089 


Fasteners  &  Metals 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

Dimensional  Inspection 

Dimensions  of  fasteners  -  straightness 
FA/423  ANSI/ASMEB18.2.1 
Dimensions  of  general  purpose  fasteners  and 
high-volume  machine  assembly  fasteners 

FA/403  ANSI/ASMEB18.18.1M 
FA/404  ANSI/ASME  B 1 8. 1 8.2M 
FA/494      ANSI  B  18.2.1 

Dimensions  of  special  purpose  fasteners  and  fasteners  for 

highly  specialized  engineered  ap 

FA/405       ANSI/ASME  Bl 8.1 8. 3M 

FA/963      ANSI  B  18.2.1 

External  thread  parameters  -  system  21 

FA/379      ANSI/ASME  B1.3M 

External  thread  parameters  -  system  22 

FA/381       ANSI/ASME  Bl. 3 M 

Internal  thread  parameters  -  system  21 

FA/391       ANSI/ASME  B1.3M 

Internal  thread  parameters  -  system  22 

FA/393       ANSI/ASME  B1.3M 

Mechanical  and  Physical  Testing  and  Inspection 

Axial  tensile  strength  of full-size  threaded  fasteners 

FA/265       ASTM  A370  Sec.  A3. 2. 1 .4 
FA/266      ASTM  F606  Sec.  3.4.1-3.4.3 
FA/273       SAE  J429 
Brinell  hardness  of  fasteners 
FA/185       ASTM  A370  Sec.  16 
FA/186      ASTM  E10 

Cone  proof  load  of  internally  threaded  fasteners  (nuts) 

FA/2 1 9      ASTM  F8 1 2/F8 1 2M 

FA/220      ASTM  F606  Sec.  4.3 

FA/655       ASTM  A194/A194M 

Hardness  preparation 

FA/482      ASTM  F606 

Measurement  of  fastener  coating  thickness  -  eddy-current 
method 

FA/ 149      ASTM  E376 

Measurement  of  fastener  coating  thickness  -  magnetic 
methods 

FA/155  ASTME376 
Microhardness  of  fasteners 
FA/654  SAEJ121 


Proof  load  of full-size  externally  threaded  fasteners 

FA/225       ASTM  A370  Sec.  A3. 2. 1 . 1  -A3. 2. 1 .3 

FA/226      ASTM  F606  Sec.  3.2.1-3.2.3 

FA/467      ASTM  F606M  Sec.  3.2. 1  -3.2.3 

Proof  load  of  internally  threaded  fasteners  (nuts) 

FA/235       ASTM  A370  Sec.  A3.5.1 

FA/236      ASTM  F606  Sec.  4.2 

FA/237      ASTM  F606M  Sec.  4.2 

Rockwell  hardness  of  fasteners 

FA/196      ASTM  A370  Sec.  18 

FA/197      ASTM  El 8 

Rockwell  superficial  hardness  of  fasteners 

FA/205       ASTM  El 8 

FA/206      ASTM  A3  70  Sec.  1 8 

Rotational  capacity  of  full-size  fasteners 

FA/243       ASTM  A325 

FA/245       ASTM  A563 

FA/965       AASHTO  Ml 64 

Wedge  tensile  strength  of full-size  threaded  fasteners 

FA/289       ASTM  A3 70 
FA/290      ASTM  F606  Sec.  3.5 
FA/291       ASTM  F606M  Sec.  3.5 
FA/468       SAE  J429  Sec.  5.5 

Metallography 

Decarburization  and  case  depth  measurement  in 
fasteners 

FA/328  SAEJ121 
FA/964      ASTM  A490 

Macroscopic  examination  of  fasteners  by  etching 

FA/336  SAEJ123 

FA/337  SAEJ1061 

FA/651       ASTM  F788/788M 

Microscopic  examination  of  fasteners  by  etching 

FA/344  SAEJ121 

Surface  discontinuities  of  externally  threaded  fasteners 

FA/357      ASTM  F788/788M 
FA/361       SAE  J 123 
FA/362       SAE  J 1061 
FA/652      ASTM  A490 

Surface  discontinuities  of  internally  threaded  fasteners 

FA/363       ASTM  F8 12 
FA/365  SAEJ122 

Nondestructive  Inspection 

Magnetic  particle  inspection  of  fasteners 

FA/374      ASTM  E709  _===_= 

NVLAP  LAB  CODE  200255-0 
Rockford  Bolt  &  Steel  Co. 

126  Mill  Street 
Rockford,  IL  61101 
Contact:  Mr.  John  Petty 
Phone:  815-968-0514 
Fax:  815-968-3111 


NVLAP  1999  DIRECTORY  -  Page  D157 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Fasteners  &  Metals 

Accreditation  Valid  Through:  December  31,1 999 

NVLAP 

Code  Designation 
Dimensional  Inspection 

Dimensions  of  fasteners  -  straightness 

FA/423       ANSI/ASMEB  18.2.1 

External  thread  parameters  -  system  21 

FA/379      ANSI/ASMEB  1.3M 

External  thread  parameters  -  system  22 

FA/381       ANSI/ASMEB  1.3M 

Mechanical  and  Physical  Testing  and  Inspection 

Axial  tensile  strength  of full-size  threaded  fasteners 
FA/266       ASTMF606  Sec.  3.4.1-3.4.3 
Hardness  preparation 
FA/482      ASTM  F606 
Rockwell  hardness  of  fasteners 
FA/202  SAEJ417 

Tension  testing  of  machined  specimens  from  externally 
threaded  fasteners 

FA/278       ASTM  A370 

FA/279       ASTM  F606  Sec.  3.6 

Wedge  tensile  strength  of  full-size  threaded  fasteners 

FA/290      ASTM  F606  Sec.  3.5 

Yield  strength  of full-size  externally  threaded  fasteners 

FA/298       ASTM  F606  Sec.  3.2.4 

FA/299       ASTM  A370  Sec.  A3. 2. 1.3(a) 

NVLAP  LAB  CODE  200256-0 
Sundram  Fasteners  Limited  Chemical  Testing 
Laboratory 

Bonthapally  Village,  Medak  District 

Andhra  Pradesh  502  313 

INDIA 

Contact:  Mr.  Sampathkumar  Moorthy 
Phone:  91-44-8521870 
Fax:  91-44-853-5435 


Fasteners  &  Metals 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 
Chemical  Analysis 

Optical  emission  spectrochemical  analysis 

FA/457       ASTM  E4 15 


NVLAP  LAB  CODE  200257-0 
Asakawa  Screw  Co.,  Ltd.  Kawawa  Factory 

1261  Nippa-cho  Kohoku-ku 

Yokohama  223 

JAPAN 

Contact:  Mr.  Tatsuhiko  Asakawa 
Phone:  045-531-1291 
Fax:  045-543-7752 


Fasteners  &  Metals 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 
Dimensional  Inspection 

Dimensions  of  fasteners  -  hexagon  and  double  hexagon 

(12  point)  and  spline  sockets 

FA/697  JISB1180 

Internal  thread  parameters  -  ISO 

FA/696  JISB1181 

Mechanical  and  Physical  Testing  and  Inspection 

Measurement  of  fastener  coating  thickness  -  X-ray 
methods 

FA/641       JIS  H8501 

Salt  spray  testing  of  fasteners 

FA/569  JISZ2371 

NVLAP  LAB  CODE  200258-0 

W.R.  Grace  &  Co. 

62  Whittemore  Avenue 

Cambridge,  MA  02140 

Contact:  Mr.  James  A.  Lee 

Phone:  617-498-4394 

Fax:  617-498-4360 

E-Mail:  james.a.lee@grace.com 

Construction  Materials  Testing 

Accreditation  Valid  Through:  December  31,  1999 


NVLAP 

Code 

Designation 

Aggregates 

02/A03 

ASTM  C29 

02/A04 

ASTM  C40 

02/A07 

ASTM  CI  17 

02/A09 

ASTM  CI 27 

02/A10 

ASTM  CI 28 

02/A12 

ASTM  CI 36 

02/A15 

ASTM  D75 

02/A44 

ASTM  C566 

Cement 

02/A17 

ASTM  CI 09 

02/A21 

ASTM  CI 57 

02/A23 

ASTM  CI 85 

02/A26 

ASTM  CI 91 

02/A27 

ASTM  C204 

02/A30 

ASTM  C266 

02/A31 

ASTM  C305 

NVLAP  1999  DIRECTORY  -  Page  D158 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


02/A32 

ASTM  C430 

02/A33 

ASTM  C45 1 

Concrete 

02/A01 

ASTM  C39 

02/A02 

ASTM  C6 17 

02/A40 

ASTM  C78 

02/A41 

ASTM  CI 92 

02/A43 

ASTM  CI 064 

02/A45 

ASTM  C42 

02/A47 

ASTM  C457 

02/G01 

ASTM  C31/C172/C143/C138/C231 

02/G02 

ASTM  CI 73 

Standard  Practices 

02/A39 

ASTM  CI 077 

NVLAP  LAB  CODE  200259-0 
PFU  TECHNOCONSUL  EMC  Center 

98-2  Nu,  Unoke,  Unoke-Machi,  Kahoku-Gun 

Ishikawa-Ken  929-1 192 

JAPAN 

Contact:  Mr.  Yasuo  Koyama 
Phone:  81-76-283-8600 
Fax:  81-76-283-8601 
E-Mail:  ykoyama@pfu.co.jp 

FCC  Test  Methods 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  la      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
12/F01b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200260-0 

Analab,  LLC 

P.O.  Box  34 
Spring  Hill  Road 
Sterling,  PA  18463 
Contact:  Mr.  Paul  Janecki 
Phone:  717-689-3919 
Fax:  717-689-3830 
E-Mail:  info@analabl.com 
URL:  http://www.analabl.com 


FCC  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO  1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

12/F01a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200261-0 

Prottsa,  S.A.  de  C.V. 

Oriente  233  No.  91  Agricola  Oriental 
CP.  08500 
Mexico  City 
MEXICO 

Contact:  Mr.  Gilberto  Laguna 
Phone:  5-558-85-77 
Fax:  5-558-25-23 


Fasteners  &  Metals 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 
Dimensional  Inspection 

Dimensions  of  general  purpose  fasteners  and 
high-volume  machine  assembly  fasteners 
FA/403  ANSI/ASMEB18.18.1M 
FA/981  ANSI/ASMEB1.3M 

Mechanical  and  Physical  Testing  and  Inspection 

Axial  tensile  strength  of full-size  threaded  fasteners 

FA/266      ASTM  F606  Sec.  3.4.1-3.4.3 

Bend  test  of  full  size  eyebolts 

FA/982      AAR  4-2-15  Section  8  (1969) 

Cone  proof  load  of  internally  threaded  fasteners  (nuts) 

FA/220      ASTM  F606  Sec.  4.3 

Hardness  preparation 

FA/482      ASTM  F606 

Measurement  of  fastener  coating  thickness  -  magnetic 
methods 

FA/153  ASTMB499 

Proof  load  of full-size  externally  threaded  fasteners 
FA/226      ASTM  F606  Sec.  3.2.1-3.2.3 
FA/983       AAR  4-2-15  Section  9  (1969) 


NVLAP  1999  DIRECTORY  -  Page  D159 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Proof  load  of  internally  threaded  fasteners  (nuts) 

FA/235       ASTM  A370  Sec.  A3. 5. 1 
FA/236      ASTM  F606  Sec.  4.2 
Rockwell  hardness  of  fasteners 
FA/196      ASTM  A370  Sec.  18 

Tension  testing  of  machined  specimens  from  externally 

threaded  fasteners 

FA/279       ASTM  F606  Sec.  3.6 

Torque-tension  of full-size  threaded  fasteners 

FA/984      AAR  4-2-15  Section  13b  (1969) 

FA/985       ASTM  A 1 83  Section  8.2.2 ' 

FA/986      Prottsa  W.I.  1.030  rev.  b 

Wedge  tensile  strength  of full-size  threaded  fasteners 

FA/290      ASTM  F606  Sec.  3.5 

Yield  strength  of full-size  externally  threaded  fasteners 

FA/298       ASTM  F606  Sec.  3.2.4 

NVLAP  LAB  CODE  200263-0 
Electro.  Meas.  Off.,  Yokohama  Res.  &  Dev.  Ctr. 
Murata  Mfg.  Co. 

Yokohama  Research  &  Development  Center 
1-18  Hakusan  1-Chome,  Midori-ku  Yokohama 
Kanagawa  226 
JAPAN 

Contact:  Mr.  Yuji  Nishimura 

Phone:  045-939-7100 

Fax:  045-939-7156 

E-Mail:  nisimura@murata.co.jp 

FCC  Test  Methods 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/F0 1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

12/F01a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
12/F01b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 


NVLAP  LAB  CODE  200264-0 
3V  Fasteners  Co.  Inc.  Testing  Laboratory 

1821  Railroad  Street 
Corona,  C A  91720 
Contact:  Mr.  Wayne  C.  Drysol 
Phone:  909-734-4391 
Fax:  909-734-0127 
E-Mail:  threevl@aol.com 

Fasteners  &  Metals 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 
Dimensional  Inspection 

Dimensions  of  fasteners  -  bearing  surface  squareness 
FA/695  3VLTI-100-1 
Dimensions  of  fasteners  -  straightness 
FA/694  3VLTI-100-1 

External  thread  parameters  -  SAE  fastener  with  MJ 

metric  screw  threads 

FA/693  FED-STD-H28/20 

External  thread  parameters  -  system  22 

FA/382  FED-STD-H28/20 

External  thread  parameters  -  system  23 

FA/386  FED-STD-H28/20 

Surface  texture 

FA/439      ANSI/ASME  B46.1 

Mechanical  and  Physical  Testing  and  Inspection 

Axial  tensile  strength  of full-size  threaded  fasteners 
FA/266       ASTM  F606  Sec.  3.4.1-3.4.3 
FA/271  MIL-STD-1312-8 
Double  shear  of  externally  threaded  fasteners 
FA/257  MIL-STD-1312-13 

Hydrogen  embrittlement  (stress  durability)  of  externally 

threaded  fasteners 

FA/176  MIL-STD-1312-5 

Magnetic  permeability 

FA/2 1 4      ASTM  A342  Test  Method  3 

Measurement  of  fastener  coating  thickness  -  dimensional 

change  method 

FA/495  MIL-STD-1312-12 

Measurement  of  fastener  coating  thickness  -  magnetic 
methods 

FA/156       FED  TM  STD  NO.  151  Method  520.1 

Measurement  of  fastener  coating  thickness  - 

microscopical  method 

FA/ 163  MIL-STD-1312-12 

Microhardness  of  fasteners 

FA/ 193  MIL-STD-1312-6 

Proof  load  of full-size  externally  threaded  fasteners 

FA/226      ASTM  F606  Sec.  3.2.1-3.2.3 

FA/691  MIL-STD-1312-8 

Recess  strength  test  in  both  the  installation  and  removal 
directions 

FA/476  MIL-STD-1312-25 


NVLAP  1999  DIRECTORY  -  Page  D160 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Rockwell  hardness  of fasteners 
FA/201  MIL-STD-1312-6 
Rockwell  superficial  hardness  of  fasteners 
FA/205  ASTME18 

Tension  testing  of  machined  specimens  from  externally 
threaded  fasteners 

FA/279      ASTM  F606  Sec.  3.6 
FA/526  MIL-STD-1312-8 

Wedge  tensile  strength  of full-size  threaded  fasteners 
FA/290      ASTM  F606  Sec.  3.5 
FA/295  MIL-STD-1312-8 

Metallography 

Decarburization  and  case  depth  measurement  in 
fasteners 

FA/483       ASTM  A574  Sec.  12 
FA/519      ASTM  A574M 
FA/692  MIL-STD-1312-6 
Determination  of  grain  size  of fasteners 
FA/331       ASTM  El  12 

Macroscopic  examination  of  fasteners  by  etching 

FA/511  ASTME340 

FA/651       ASTM  F788/788M 

Microscopic  examination  of  fasteners  by  etching 

FA/341       ASTM  El 077 

FA/345       ASTM  F788/788M 

FA/346      ASTM  F788/788M 

FA/351       ASTM  El  12 

FA/512  ASTME407 

FA/552      ASTM  E3 

FA/679      ASTM  A574 

Surface  discontinuities  of  externally  threaded  fasteners 
FA/357      ASTM  F788/788M 

NVLAP  LAB  CODE  200265-0 

R  &  D  Services,  Inc. 

2594  West  Broad  Street 
P.O.  Box  2400 
Cookeville,  TN  38502-2400 
Contact:  Mr.  Ronald  S.  Graves 
Phone:  931-372-8871 
Fax:  931-525-3896 
E-Mail:  rdserv@usit.net 
URL:  http://rdservices.com 

Thermal  Insulation  Materials 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 
Corrosiveness 

01/C01       ASTM  C739  (Sec.  9) 
01/C02       16  CFR-Part  1209.5 
Flammability 

01/F08        16  CFR-Part  1209.7 
01/F10       ASTM  C739  (Sec.  14) 
Mass,  Density,  and  Dimensional  Stability 
01/D02       ASTM  CI 67 
01/D26       16  CFR-Part  1209.4 
01/D27       ASTM  C739  (Sec.  8) 


Related  Material  Properties 

01/V05       ASTM  C739  (Sec.  11) 
01/V06       ASTM  C739  (Sec.  15) 
Thermal  Resistance 
01/T06       ASTM  C5 18 
01/T10  ASTMC687 

NVLAP  LAB  CODE  200266-0 
Aerospace  Rivet  Manufacturers  Corp. 

8535  Dice  Road 

Santa  Fe  Springs,  CA  90670-2509 
Contact:  Mr.  Caesar  Bansil 
Phone: 562-945-5456 
Fax:  562-696-6398 


Fasteners  &  Metals 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 
Dimensional  Inspection 

Dimensions  of  general  purpose  fasteners  and 
high-volume  machine  assembly  fasteners 
FA/403  ANSI/ASMEB18.18.1M 
Mechanical  and  Physical  Testing  and  Inspection 

Axial  tensile  strength  of full-size  threaded  fasteners 

FA/271  MIL-STD-1312-8 

Double  shear  of  externally  threaded  fasteners 

FA/257  MIL-STD-1312-13 

Magnetic  permeability 

FA/2 1 4      ASTM  A342  Test  Method  3 

Measurement  of  fastener  coating  thickness  - 

microscopical  method 

FA/160  ASTMB487 

FA/163       MIL-STD-13 12-12 

Microhardness  of  fasteners 

FA/ 189      ASTM  E3  84 

Recess  strength  test  in  both  the  installation  and  removal 
directions 

FA/476       MIL-STD-13 12-25 

Rockwell  hardness  of  fasteners 

FA/201  MIL-STD-1312-6 

Salt  spray  testing  of  fasteners 

FA/166      ASTM  Bl  17 

FA/168       MIL-STD-13 12-1 

Single  shear  of  externally  threaded  fasteners 

FA/256      MIL-STD-13 12-20 

Water  immersion  method  -  test  for  anodic  surface 

containment  on  corrosion  resistant  fasten 

FA/756      MIL-STD-753  Test  100 

Metallography 

Determination  of  grain  size  of fasteners 

FA/638       ASTM  El  12 

Microscopic  examination  of  fasteners  by  etching 
FA/351       ASTM  El  12 


NVLAP  1999  DIRECTORY  -  Page  D161 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Nondestructive  Inspection 

Liquid  penetrant  inspection  of  fasteners 

FA/527      ASTM  E1417 

Magnetic  particle  inspection  of  fasteners 

FA/485       ASTM  El 444 

NVLAP  LAB  CODE  200267-0 
Multifastener  Laboratory 

22100  Trolley  Industrial  Drive 

Taylor,  MI  48180 

Contact:  Ms.  Michele  Stawowy 

Phone:  313-299-1178 

Fax:  313-299-1  190 

E-Mail:  stawowym@aol.com 

Fasteners  &  Metals 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

Mechanical  and  Physical  Testing  and  Inspection 

Axial  tensile  strength  of full-size  threaded  fasteners 

FA/265       ASTM  A370  Sec.  A3. 2. 1 .4 

FA/266       ASTM  F606  Sec.  3.4.1-3.4.3 

FA/267       ASTM  F606M  Sec.  3.4.1-3.4.3 

FA/270       ISO  898-1  Sec.  8.2 

FA/273       SAE  J429 

FA/274       SAE  Jl 216 

Prevailing  torque 

FA/216      ANSI  B  18.1 6. 1M 

FA/218       ISO  2320 

Proof  load  of  full-size  externally  threaded  fasteners 

FA/225       ASTM  A370  Sec.  A3. 2. 1.1 -A3. 2. 1.3 

FA/226      ASTM  F606  Sec.  3.2.1-3.2.3 

FA/228       ISO  898-1  Sec.  8.4 

FA/229       SAE  J429  Sec.  5.3 

FA/230      SAEJ1216Sec.  3.3 

FA/467      ASTM  F606M  Sec.  3.2.1-3.2.3 

Proof  load  of  internally  threaded  fasteners  (nuts) 

FA/235       ASTM  A370  Sec.  A3.5. 1 

FA/236       ASTM  F606  Sec.  4.2 

FA/237      ASTM  F606M  Sec.  4.2 

FA/239      ISO  898-2  Sec.  8.1 

FA/240      ISO  898-6  Sec.  8.1 

FA/241       SAE  J995  Sec.  5.1 

FA/242       SAE  Jl 21 6  Sec  4.2 

Rockwell  hardness  of  fasteners 

FA/196      ASTM  A370  Sec.  18 

FA/ 197      ASTM  El 8 

FA/200      ISO  6508 

FA/202  SAEJ417 

Rockwell  superficial  hardness  of  fasteners 

FA/205       ASTM  El 8 

FA/206       ASTM  A370  Sec.  18 

FA/208       ISO  1024 

FA/210  SAEJ417 

Test  for  embrittlement  of  metallic  coated  externally 
threaded  fasteners 

FA/179      ASTM  F606  Sec.  7 


FA/1 80      ASTM  F606M  Sec.  7 

NVLAP  LAB  CODE  200268-0 
The  Monadnock  Company 

1 8301  East  Arenth  Avenue 
City  of  Industry,  CA  91748-1288 
Contact:  Mr.  Belen  Guevara 
Phone:  818-964-6581 
Fax:  818-965-5481 


Fasteners  &  Metals 

Accreditation  Valid  Through:  March  31,  1999 
NVLAP 

Code  Designation 
Dimensional  Inspection 

Dimensions  of  fasteners  -  bearing  surface  squareness 

FA/633  MIL-N-25027 

External  thread  parameters  -  system  21 

FA/380  FED-STD-H28/20A 

External  thread  parameters  -  system  22 

FA/382  FED-STD-H28/20A 

External  thread  parameters  -  system  23 

FA/386  FED-STD-H28/20A 

Internal  thread  parameters  -  system  21 

FA/392  FED-STD-H28/20A 

Internal  thread  parameters  -  system  22 

FA/394  FED-STD-H28/20A 

Internal  thread  parameters  -  system  23 

FA/398  FED-STD-H28/20A 

Surface  texture 

FA/439       ANSI/ASME  B46.1 

Mechanical  and  Physical  Testing  and  Inspection 

Adhesion  of  metallic  coatings  on  fasteners 

FA/779  BSS7225 

Axial  tensile  strength  of full-size  threaded  fasteners 

FA/271  MIL-STD-1312-8 

FA/757  MIL-STD-1312-23 

Compression  load  of  compressible-washer-type  direct 

tension  indicators 

FA/778  BACW10CA 

Copper  sulfate  test  -  test  for  free  iron  on  the  surface  of 

corrosion  resistant  fasteners 

FA/636      MIL-STD-753  Test  102 

Hydrogen  embrittlement  (stress  durability)  of  internally 

threaded  fasteners 

FA/178  MIL-STD-1312-14 

FA/772  BACN10YD 

FA/773  BACN10FX 

FA/888  BACN11K 

Magnetic  permeability 

FA/2 1 4      ASTM  A342  Test  Method  3 

Measurement  of  fastener  coating  thickness  -  eddy-current 

method 

FA/ 148  ASTMB244 


NVLAP  1999  DIRECTORY  -  Page  D162 


(See  'How  To  Use  This  Directory1  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Measurement  of  fastener  coating  thickness  - 

microscopical  method 

FA/160  ASTMB487 

Microhardness  of  fasteners 

FA/193  MIL-STD-1312-6 

Prevailing  torque 

FA/630  MIL-N-25027 

Reusability  test  of  self-locking  internally  threaded 
fasteners 

FA/124  MIL-N-25027 

FA/774  BPS-N-70 

Rockwell  hardness  of  fasteners 

FA/201  MIL-STD-1312-6 

Rockwell  superficial  hardness  of  fasteners 

FA/209  MIL-STD-1312-6 

Torque-out  test 

FA/133  MIL-N-25027 

FA/775  BACN10YD 

FA/776  BACN10VR 

FA/777  BACN10FX 

FA/887  BACN11K 

Water  immersion  method  -  test  for  anodic  surface 

containment  on  corrosion  resistant  fasten 

FA/756      MIL-STD-753  Test  100 

Wrench  torque  test  of  externally  wrenched  nuts  of  spline 

and  hexagon  and  double  hexagon  (1 

FA/141  MIL-N-25027   

NVLAP  LAB  CODE  200271-0 
Aerospace  NYLOK  -  a  subsidiary  of  the  NYLOK 
Fastener  Corporation 
1 1  Thomas  Road  South 
Hawthorne,  NJ  07507-0651 
Contact:  Mr.  Chet  Radwan 
Phone:  973-427-8555 
Fax:  973-427-4723 


Fasteners  &  Metals 

Accreditation  Valid  Through:  March  31,  1999 
NVLAP 

Code  Designation 
Dimensional  Inspection 

Dimensions  of  special  purpose  fasteners  and  fasteners  for 
highly  specialized  engineered  ap 
FA/805       MIL-DTL- 18240 
FA/806      MIL-F- 18240 

Mechanical  and  Physical  Testing  and  Inspection 

Prevailing  torque 

FA/217  IFI-100/107 

FA/794  MIL-DTL- 18240 

FA/795  IFI  124 

FA/796  MIL-F- 18240 

FA/797  IFI  125 

FA/798  IFI  524 

FA/833  IFI 525 


Reusability  test  of  self-locking  internally  threaded 
fasteners 

FA/792      MIL-F- 1 8240  (externally  and  internally 
threaded) 

FA/793       MIL-DTL- 1 8240  (externally  and  internally 
threaded) 

NVLAP  LAB  CODE  200272-0 
NYLOK  Fastener  Corporation 

313  North  Euclid  Way 
Anaheim,  CA  92801-6738 
Contact:  Mr.  Maynard  Axvig 
Phone:  714-635-3993 
Fax:  714-635-9553 


Fasteners  &  Metals 

Accreditation  Valid  Through:  March  31,  1999 
NVLAP 

Code  Designation 
Dimensional  Inspection 

Dimensions  of  special  purpose  fasteners  and  fasteners  for 
highly  specialized  engineered  ap 


FA/802 

NYLOK  TP-NW-5.0 

External  thread  parameters  -  system  21 

FA/379 

ANSI/ASMEB1.3M 

FA/380 

FED-STD-H28/20A 

External  thread  parameters  -  system  22 

FA/381 

ANSI/ASMEB1.3M 

FA/382 

FED-STD-H28/20A 

FA/383 

MIL-S-7742 

FA/384 

MIL-S-8879 

FA/534 

SAE  AS  8879 

FA/803 

ASMEB1.15 

Internal  thread  parameters  -  system  21 

FA/391 

ANSI/ASME  B1.3M 

FA/392 

FED-STD-H28/20A 

Internal  thread  parameters  -  system  22 

FA/393 

ANSI/ASME  B1.3M 

FA/394 

FED-STD-H28/20A 

FA/395 

MIL-S-7742 

FA/396 

MIL-S-8879 

FA/537 

SAE  AS  8879 

FA/804 

ASMEB1.15 

Mechanical  and  Physical  Testing  and  Inspection 

Axial  tensile  strength  of full-size  threaded  fasteners 
FA/266      ASTM  F606  Sec.  3.4.1-3.4.3 
FA/799      NASM  1312-8 

Hydrogen  embrittlement  (stress  durability)  of  externally 
threaded  fasteners 
FA/801  QQ-P-416 

Hydrogen  embrittlement  (stress  durability)  of  internally 
threaded  fasteners 
FA/800  QQ-P-416 
Prevailing  torque 

FA/217  IFI-100/107 
FA/794      MIL-DTL- 18240 
FA/795       IFI  124 


NVLAP  1999  DIRECTORY  -  Page  D163 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


FA/796  MIL-F- 18240 

FA/797  IFI  125 

FA/798  IFI  524 

Reusability  test  of  self-locking  internally  threaded 
fasteners 

FA/792  MIL-F- 18240 

FA/793  MIL-DTL- 18240  

NVLAP  LAB  CODE  200273-0 
NYLOK  Fastener  Corporation 

15260  Hallmark  Drive 
Macomb,  MI  48042-4007 
Contact:  Mr.  Glenn  Graybill 
Phone:  810-786-0100 
Fax:  810-786-0498 


Fasteners  &  Metals 

Accreditation  Valid  Through:  March  31,  1999 
NVLAP 

Code  Designation 
Dimensional  Inspection 

Dimensions  of  special  purpose  fasteners  and  fasteners  for 

highly  specialized  engineered  ap 

FA/802      NYLOK  TP-NW-5.0 

Mechanical  and  Physical  Testing  and  Inspection 

Prevailing  torque 

FA/216  ANSI  B18.16.1M 

FA/217  IFI-100/107 

FA/557  DIN  267,  Part  15 

FA/795  IFI  124 

FA/796  MIL-F-18240 

FA/797  IFI  125 

FA/798  IFI  524 

FA/807  GM6189P 

FA/808  Ford  ES3 82 101 -SI 00 

FA/809  Ford  ES-N800688-S 100 

FA/810  Ford  ES-384103-S-A 

FA/811  Ford  WA  970 

FA/812  Ford  ES-F77U-9E926-AA 

FA/813  Chrysler  PF-5077 

FA/814  Chrysler  PF-5 144 

FA/815  Chrysler  PF-5461 

FA/816  Chrysler  PF-5683 

FA/817  Chrysler  PF-6 157 

FA/818  Chrysler  PF-6 158 

FA/819  DIN  267,  Part  27 

FA/820  Navistar  0810 

FA/821  GMTES-113 

FA/822  BendixW1287 

FA/823  Mack  Trucks  10AMSI 

FA/824  Mack  Trucks  3AXS5 

FA/825  Mack  Trucks  6AXS5 

FA/826  Allied  Signal  WI-504 

FA/827  GM6175M 

FA/828  Ford  ES-20010-S 100 

FA/829  Ford  ES-20007-S 1 00 

FA/830  Ford  WX  200 

FA/831  Ford  WSS-M1 1P45-A! 


FA/832 

Ford  ESS-MI  1P24-A1 

FA/833 

IFI 525 

FA/834 

Rockwell  International  Q-29 

FA/835 

Ford  ES-N804199-S192 

FA/836 

Ford  WE  950 

FA/837 

Ford  ES-21002-S100 

FA/838 

Ford  ES-21006-S100 

r  A/839 

T?  1  T-'C"        1  AAA    O  1  AA 

r  ord  LS-2 1 000-S 1 00 

FA/840 

Chrysler  MS-CD914 

FA/841 

GM  6076M 

FA/842 

Chrysler  PS-8542 

Torque-tension  of full-size  threaded  fasteners 
FA/307  MIL-STD-1312-15 
FA/308       SAE  J 174 

NVLAP  LAB  CODE  200274-0 
Kyowa  Kogyosyo  Co.,  Ltd.  Test  Laboratory 

1-57,  Kogyo-Danchi 
Komatsu  City,  Ishikawa 
JAPAN 

Contact:  Mr.  Mataichi  Fukuda 
Phone:  81-761-21-0531 
Fax:  81-761-21-0533 


Fasteners  &  Metals 

Accreditation  Valid  Through:  June  30,  1999 

NVLAP 

Code  Designation 
Dimensional  Inspection 

Dimensions  of  ISO  grade  A  and  B  fasteners 
FA/589  JISB1071 

Dimensions  of  fasteners  -  bearing  surface  squareness 

FA/649      JISB  1071 

Dimensions  of  fasteners  -  straightness 

FA/648  JISB1071 

External  thread  parameters  -  system  21 

FA/647  JISB1071 

Surface  texture 

FA/650  JISB1071 

Mechanical  and  Physical  Testing  and  Inspection 

Axial  tensile  strength  of full-size  threaded  fasteners 

FA/266       ASTM  F606  Sec.  3.4.1-3.4.3 
FA/574      JISB 1051  Sec.  4.2.2 
Charpy  impact  (u-notch)  testing 
FA/845       JIS  Z2242 
Hardness  preparation 
FA/482      ASTM  F606 

Measurement  of  fastener  coating  thickness  -  magnetic 
methods 

FA/596       JIS  H8501 

Microhardness  of  fasteners 

FA/620      JIS  Z2244 

FA/642      JIS  B1051  Sec.  4.2.5 

Proof  load  of full-size  externally  threaded  fasteners 

FA/573       JISB  1051  Sec.  4.2.4 


NVLAP  1999  DIRECTORY  -  Page  D164 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Rockwell  hardness  of  fasteners 
FA/197  ASTME18 
FA/572      JIS  Z2245 
FA/707      JIS  B1051  Sec.  4.2.5 

Tension  testing  of  machined  specimens  from  externally 
threaded  fasteners 

FA/581       JIS  B1051  Sec.  4.2.1 
FA/582  JISZ2241 

Wedge  tensile  strength  of  full-size  threaded  fasteners 
FA/290      ASTM  F606  Sec.  3.5 
FA/575       JIS  B 1051  Sec.  4.2.3 

Metallography 

Decarburization  and  case  depth  measurement  in 
fasteners 

FA/645       JIS  B 1051 

Surface  discontinuities  of  externally  threaded  fasteners 
FA/603       JIS  B 104  3 

NVLAP  LAB  CODE  200275-0 
NYLOK  Fastener  Corporation  -  Chicago  Testing 
Laboratory 

6465  Proesel  Avenue 
Lincolnwood,  IL  60645 
Contact:  Mr.  Peter  Beck 
Phone:  800-446-5956 
Fax:  847-674-1269 


Fasteners  &  Metals 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 
Dimensional  Inspection 

Dimensions  of  special  purpose  fasteners  and  fasteners  for 

highly  specialized  engineered  ap 

FA/850      NYLOK  TP-NC-5.0 

Mechanical  and  Physical  Testing  and  Inspection 

Prevailing  torque 

FA/846  NYLOK  TP-NC- 1 .0 
FA/847  NYLOK  TP-NC-2.0 
FA/848      NYLOK  TP-NC-3.0 

FA/849      NYLOK  TP-NC-4  >  >   

NVLAP  LAB  CODE  200276-0 
Yamaha  Motor  Metal  Testing  Laboratory 
Fasteners  and  Metals 

2500  Shingai 

Iwata  Shizuoka  438-8501 

JAPAN 

Contact:  Mr.  Shinobu  Mizukoshi 
Phone:  81-538-37-4031 
Fax:  81-538-37-4297 

E-Mail:  mizukoshi.shinobu@ccgw.yamaha-motor.co.jp 


Fasteners  &  Metals 

Accreditation  Valid  Through:  March  31,  1999 
NVLAP 

Code  Designation 
Chemicai  Analysis 

Combustion  analysis  for  carbon,  sulfur,  oxygen, 

nitrogen,  and  hydrogen 

FA/586  JISG1211 

FA/587  JISG1215 

Optical  emission  spectrochemical  analysis 

FA/588      JIS  G 1253 

Dimensional  Inspection 

Dimensions  of  general  purpose  fasteners  and 
high-volume  machine  assembly  fasteners 

FA/607  JIS  B 1071 
FA/856  JISB1251 
FA/857  JISB1256 

Mechanical  and  Physical  Testing  and  Inspection 

Axial  tensile  strength  of full-size  threaded  fasteners 
FA/574      JIS  B1051  Sec.  4.2.2 

CASS  test  (copper-accelerated  acetic  acid-salt  spray  test) 
of fasteners 

FA/599      JIS  H8502 

Compression  load  of  compressible-washer-type  direct 
tension  indicators 
FA/858  JISB1251 

Measurement  of  fastener  coating  thickness  -  X-ray 
methods 

FA/641  JISH8501 

Measurement  of  fastener  coating  thickness  - 

microscopical  method 

FA/640  JISH8501 

Microhardness  of  fasteners 

FA/620      JIS  Z2244 

FA/642      JIS  B1051  Sec.  4.2.5 

Proof  load  of full-size  externally  threaded  fasteners 

FA/573       JIS  B 1051  Sec.  4.2.4 

Rockwell  hardness  of  fasteners 

FA/572      JIS  Z2245 

FA/616      JIS  B 1051  Sec.  4.3 

Salt  spray  testing  of  fasteners 

FA/569  JISZ2371 

Twist  test  of  lock  washers 

FA/678      JIS  B 1251 

Wedge  tensile  strength  of full-size  threaded  fasteners 
FA/575       JIS  B 1051  Sec.  4.2.3 
Metallography 

Decarburization  and  case  depth  measurement  in 
fasteners 

FA/645       JIS  B 1051 

Surface  discontinuities  of  externally  threaded  fasteners 

FA/603  JIS  B 1043 
FA/646      JIS  B 1041 


NVLAP  1999  DIRECTORY  -  Page  D165 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  200277-0 
Vulcan  Rivet  and  Bolt  Corporation 

1020  Pinson  Valley  Parkway 
P.O.  Box  170129 
Birmingham,  AL  35217-0129 
Contact:  Mr.  Anil  P.  Agarwal 
Phone:  205-841-271 1 
Fax:  205-841-2722 


Fasteners  &  Metals 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Mechanical  and  Physical  Testing  and  Inspection 

Axial  tensile  strength  of full-size  threaded  fasteners 
FA/266       ASTMF606  Sec.  3.4.1-3.4.3 
FA/267       ASTMF606M  Sec.  3.4.1-3.4.3 
FA/273       SAE  J429 
Rockwell  hardness  of  fasteners 
FA/196       ASTM  A370  Sec.  18 
Single  shear  of  externally  threaded  fasteners 
FA/255       ASTM  F606 

Tension  testing  of  machined  specimens  from  externally 
threaded  fasteners 

FA/279       ASTM  F606  Sec.  3.6 
FA/280       ASTM  F606M  Sec.  3.6 
FA/283       SAE  J429 

Wedge  tensile  strength  of full-size  threaded  fasteners 

FA/290      ASTM  F606  Sec.  3.5 
FA/291       ASTM  F606M  Sec.  3.5 
FA/468       SAE  J429  Sec.  5.5 

NVLAP  LAB  CODE  200278-0 

Casey  Products,  Inc. 

1955  University  Lane 

Lisle,  1L  60532-4149 

Contact:  Mr.  Michael  B.  Connelly 

Phone:  630-960-3360 

Fax:  630-960-3419 


Fasteners  &  Metals 

Accreditation  Valid  Through:  March  31,  1999 
NVLAP 

Code  Designation 
Dimensional  Inspection 

Dimensions  of  ISO  grade  A  and  B  fasteners 

FA/407       ISO  3269 

FA/408       ISO  4759-1 

Dimensions  of  ISO  grade  C  fasteners 

FA/409       ISO  3269 
FA/410       ISO  4759-1 

Dimensions  of  fasteners  -  hexagon  and  double  hexagon 
(12  point)  and  spline  sockets 
FA/411       ANSI/ASME  B18.3 
FA/412       ANSI/ASME  B18. 3. 1M 


FA/413       ANSI/ASME  Bl 8. 3. 3M 

FA/414      ANSI/ASME  B18.3.4M 

FA/415       ANSI/ASME  Bl  8.3. 5M 

FA/416       ANSI/ASME  B18.3.6M 

Dimensions  of  fasteners  -  straightness 

FA/423       ANSI/ASME  B 1 8.2. 1 

FA/424      ANSI/ASME  Bl 8.2.3. 1M 

FA/425       ANSI/ASME  B18. 2.3. 2M 

FA/426       ANSI/ASME  B18.2. 3. 3M 

FA/427       ANSI/ASME  B  18.2. 3. 4M 

FA/428       ANSI/ASME  B18.2. 3. 5M 

FA/429       ANSI/ASME  B18.2.3.6M 

FA/433       ANSI/ASME  Bl 8.5. 2.2M 

Dimensions  of  general  purpose  fasteners  and 

high-volume  machine  assembly  fasteners 

FA/403       ANSI/ASME  B 18. 18.1  M 

FA/404      ANSI/ASME  B 1 8. 1 8.2M 

FA/486       MIL-STD-120  (W/  Notice  dtd  9  SEP  63) 

FA/870      ANSI/ASME  B1.16M 

FA/871       ANSI/ASME  B  1.2 

Dimensions  of  special  purpose  fasteners  and  fasteners  for 

highly  specialized  engineered  ap 

FA/405       ANSI/ASME  B  18.1 8. 3M 

FA/406       ANSI/ASME  Bl 8. 18.4M 

External  thread  parameters  -  ISO 

FA/390       ISO  1502 

External  thread  parameters  -  system  21 

FA/379       ANSI/ASME  B1.3M 

External  thread  parameters  -  system  22 

FA/381       ANSI/ASME  B1.3M 

Internal  thread  parameters  -  ISO 

FA/402       ISO  1502 

Internal  thread  parameters  -  system  21 

FA/391       ANSI/ASME  B1.3M 

Internal  thread  parameters  -  system  22 

FA/393       ANSI/ASME  B1.3M 

Mechanical  and  Physical  Testing  and  Inspection 

Axial  tensile  strength  of full-size  threaded  fasteners 

FA/265       ASTM  A370  Sec.  A3. 2. 1 .4 
FA/266       ASTM  F606  Sec.  3.4.1-3.4.3 
FA/267       ASTM  F606M  Sec.  3.4. 1  -3.4.3 
FA/270       ISO  898-1  Sec.  8.2 
FA/273       SAE  J429 
FA/274       SAE  Jl  2 16 
Hardness  preparation 
FA/464      ASTM  F606M 
FA/482       ASTM  F606 

Measurement  of  fastener  coating  thickness  -  eddy-current 
method 

FA/149  ASTME376 

Measurement  of  fastener  coating  thickness  -  magnetic 
methods 

FA/155  ASTME376 
Microhardness  of  fasteners 
FA/189  ASTME384 
Prevailing  torque 
FA/217      IFI- 100/1 07 


NVLAP  1999  DIRECTORY  -  Page  D166 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Proof  load  of  full-size  externally  threaded  fasteners 

FA/225       ASTM  A370  Sec.  A3. 2. 1 . 1  -A3 .2. 1 .3 

FA/226      ASTM  F606  Sec.  3.2.1-3.2.3 

FA/228      ISO  898-1  Sec.  8.4 

FA/229       SAE  J429  Sec.  5.3 

FA/467      ASTM  F606M  Sec.  3.2.1-3.2.3 

FA/577       SAE  J1216  Sec.  3.3 

Proof  load  of  internally  threaded  fasteners  (nuts) 

FA/235       ASTM  A370  Sec.  A3. 5. 1 

FA/236      ASTM  F606  Sec.  4.2 

FA/237      ASTM  F606M  Sec.  4.2 

FA/239      ISO  898-2  Sec.  8.1 

FA/241       SAE  J995  Sec.  5.1 

Rockwell  hardness  of  fasteners 

FA/196      ASTM  A370  Sec.  18 

FA/197      ASTM  El 8 

Rockwell  superficial  hardness  of  fasteners 

FA/205       ASTM  El 8 

FA/206      ASTM  A370  Sec.  1 8 

Test  for  embrittlement  of  metallic  coated  externally 

threaded  fasteners 

FA/179      ASTM  F606  Sec.  7 

FA/1 80      ASTM  F606M  Sec.  7 

Total  extension  at  fracture  of  externally  threaded 

fasteners 

FA/285       ASTM  F606  Sec.  3.7 

FA/286      ASTM  F606M  Sec.  3.7 

Wedge  tensile  strength  of full-size  threaded  fasteners 

FA/289      ASTM  A370 

FA/290      ASTM  F606  Sec.  3.5 

FA/291       ASTM  F606M  Sec.  3.5 

FA/294      ISO  898-1  Sec.  8.5 

FA/468       SAE  J429  Sec.  5.5 

FA/469       SAE  Jl 21 6  Sec.  3.6 

Yield  strength  of full-size  externally  threaded  fasteners 

FA/298      ASTM  F606  Sec.  3.2.4 
FA/300      ASTM  F606M  Sec.  3.2.4 

Metallography 

Decarburization  and  case  depth  measurement  in 
fasteners 

FA/323       ASTM  El 077 

FA/324      ISO  898-1 

FA/325       ISO  898-5 

FA/328  SAEJ121 

FA/329  SAEJ419 

FA/330      SAE  J423 

FA/483       ASTM  A574  Sec.  12 

FA/519      ASTM  A574M 

FA/520      ASTM  F835 

FA/758       SAE  J121M 

FA/866       ASTM  F835M 

FA/867      ASTM  F9 12 

FA/868       ASTM  F912M 

Determination  of  grain  size  of fasteners 

FA/638      ASTM  El  12 

Macroscopic  examination  of  fasteners  by  etching 
FA/484      ASTM  E3  81 
FA/511  ASTME340 


Microscopic  examination  of  fasteners  by  etching 

FA/512  ASTME407 

Surface  discontinuities  of  externally  threaded  fasteners 


FA/357 

ASTM  F788/788M 

FA/359 

ISO  6157-1 

FA/360 

ISO  6157-3 

FA/361 

SAE  J 123 

FA/362 

SAE  J1061 

FA/859 

ASTM  A574 

FA/860 

ASTM  A574M 

FA/861 

ASTM  F835 

FA/862 

ASTM  F835M 

FA/863 

ASTM  F9 12 

FA/864 

ASTM  F912M 

Surface  discontinuities  of  internally  threaded  fasteners 

FA/365  SAEJ122 
FA/727       ISO  6157-2 
FA/865       ASTM  F812/F812M 

NVLAP  LAB  CODE  200279-0 
Federal  Manufacturing  Corp. 

9825  Desoto  Avenue 
Chatsworth,  CA  91311 
Contact:  Mr.  Drew  Haney 
Phone:  818-341-9825 
Fax:  818-341-9913 


Fasteners  &  Metals 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 
Dimensional  Inspection 

External  thread  parameters  -  system  22 
FA/381       ANSI/ASME  B1.3M 
FA/382  FED-STD-H28/20 
External  thread  parameters  -  system  23 
FA/385       ANSI/ASME  B1.3M 
FA/386  FED-STD-H28/20 
FA/388  MIL-S-8879 

Mechanical  and  Physical  Testing  and  Inspection 

Axial  tensile  strength  of full-size  threaded  fasteners 

FA/799      NASM  1312-8 

Double  shear  of  externally  threaded  fasteners 

FA/880      NASM  1312-13 

Fatigue  of  full-size  threaded  fasteners 

FA/876      NASM  1312-11 

Magnetic  permeability 

FA/2 1 4      ASTM  A342  Test  Method  3 

Measurement  of  fastener  coating  thickness  -  magnetic 

methods 

FB/1003  NASM  1312-12 
Microhardness  of  fasteners 

FA/ 189      ASTM  E3 84 
FA/877      NASM  1312-6 


NVLAP  1999  DIRECTORY  -  Page  D167 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Recess  strength  test  in  both  the  installation  and  removal 
directions 

FA/886      NASM  1312-25 

Rockwell  hardness  of  fasteners 

FA/878      NASM  1312-6 

Rockwell  superficial  hardness  of  fasteners 

FB/1004     NASM  1312-6 

Wedge  tensile  strength  of full-size  threaded  fasteners 

FB/1005     NASM  1312-8 

Metallography 

Determination  of  grain  size  of fasteners 
FA/331  ASTME112 

Microscopic  examination  of  fasteners  by  etching 
FA/512  ASTME407 

NVLAP  LAB  CODE  200280-0 
Super  Cheng  Industrial  Testing  Laboratory 

No.  15,  Wei-Swei  W.  Road 
Kaohsiung,  Kangshan  82005 
TAIWAN 

Contact:  Mr.  Min  Long  Yu 
Phone:  886-7-622-5326 
Fax:  886-7-621-5377 
E-Mail:  supcheng@msl.hinet.net 

Fasteners  &  Metals 

Accreditation  Valid  Through:  March  31,  1999 
NVLAP 

Code  Designation 
Dimensional  Inspection 

Dimensions  of  fasteners  -  bearing  surface  squareness 

FA/746       ASME/ANSI  B 1 8.2.2 
FA/761  JISB1196 

Dimensions  of fasteners  -  flange  screw  heads  and  flange 
nuts 

FA/566       IFI  D21  p.  D21 
FA/764      DIN  6923 

Dimensions  of fasteners  -  gaging  for  slotted  nuts 

FA/417  ANSI/ASMEB18.2.2 
FA/763       DIN  935,  Part  3 

Dimensions  of  fasteners  -  hexagon  and  double  hexagon 

(12  point)  and  spline  sockets 

FA/843       ASME/ANSI  B  18.2.2 

Dimensions  of  general  purpose  fasteners  and 

high-volume  machine  assembly  fasteners 

FA/404       ANSI/ASME  B 1 8. 1 8.2M 

FA/844       DIN  Handbook  140 

Internal  thread  parameters  -  SAE  fastener  with  MJ 

metric  screw  threads 

FA/762       ANSI/ASME  B1.3M 

Mechanical  and  Physical  Testing  and  Inspection 

Hardness  preparation 

FA/464      ASTM  F606M 
FA/482       ASTM  F606 


Measurement  of  fastener  coating  thickness  -  X-ray 
methods 

FA/760      ASTM  A754/A754M 

Measurement  of  fastener  coating  thickness  -  coulometric 
method 

FA/567      ASTM  B504 
Prevailing  torque 
FA/217  IFI-100/107 

Proof  load  of  internally  threaded  fasteners  (nuts) 

FA/236      ASTM  F606  Sec.  4.2 
FA/237      ASTM  F606M  Sec.  4.2 
FA/241       SAE  J995  Sec.  5.1 
Rockwell  hardness  of  fasteners 
FA/197      ASTM  El 8 
Rockwell  superficial  hardness  of  fasteners 
FA/205       ASTM  El 8 

Vickers  hardness  -  test  forces  from  9.807  to  1176  N  (1  to 
120  kgj) 

FA/492       ASTM  E92 
Metallography 

Decarburization  and  case  depth  measurement  in 
fasteners 

FA/324  ISO  898-1 
FA/328  SAEJ121 
FA/521  ASTME384 

Surface  discontinuities  of  externally  threaded  fasteners 

FA/357       ASTM  F788 
FA/358       ASTM  F788M 

Surface  discontinuities  of  internally  threaded  fasteners 

FA/363       ASTM  F8 12 
FA/364       ASTM  F812M 

NVLAP  LAB  CODE  200281-0 
Fujitsu  Evaluation  Engineering  Laboratory 

140  Miyamoto 

Numazu,  Shizuoka-Pref.  410-0396 
JAPAN 

Contact:  Mr.  Yoshiyuki  Okita 
Phone:  81-559-24-7209 
Fax:  81-559-24-6183 
E-Mail:  okita@psl.fujitsu.co.jp 

FCC  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AVSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 

1 2/F0 1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO 1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  1  b      Radiated  Emissions 


NVLAP  1999  DIRECTORY  -  Page  D168 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

1 2/CIS22    IEC/CISPR  22: 1 993 :  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200282-0 
Electronics  Test  Centre 

302  Legget  Drive,  Unit  100 
Kanata,  Ont.  K2K  1Y5 
CANADA 

Contact:  Mr.  Dave  Scribailo 
Phone:  613-599-6800 
Fax:  613-599-7614 

E-Mail:  daves@mpb-technologies.com 
FCC  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AU ST  EL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

12/F01a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22: 1 993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200283-0 
Duro-Test  Corporation 

185  Scoles  Avenue 

Clifton,  NJ  07012 

Contact:  Mr.  Denis  McNamee 

Phone:  973-472-1900 

Fax:  973-472-5220 

E-Mail:  dmcnamee@duro-test.com 

Energy  Efficient  Lighting  Products 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

Color  Measurements 

22/C01       IES  LM-58 
Electrical  Measurements 
22/E01       IES  LM-9 
22/E02       IES  LM-45 
22/E03       IES  LM-5 1 
22/E04       IES  LM-66 


Photometric  Measurements 

22/PO la      IES  LM-9  (Total  Flux) 

22/P02a      IES  LM-20  (Total  Flux) 

22/P03a      IES  LM-45  (Total  Flux) 

22/P04a      IES  LM-51  (Total  Flux) 

22/P05a      IES  LM-66  (Total  Flux)  

NVLAP  LAB  CODE  200285-0 
Sony  Atsugi  EMC  Site 

6-7-35,  Kitashinagawa 
Shinagawa,  Tokyo,  141-0001 
JAPAN 

Contact:  Mr.  Noriyoshi  Iwasaki 

Phone:  81-3-5448-4162 

Fax:  81-3-5448-2389 

E-Mail:  noriyoshi@apl.sony.co.jp 

FCC  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO  1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  la      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

1 2/CIS22    IEC/CISPR  22: 1 993 :  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200286-0 
Fwu  Kuang  Enterprises  Co.,  Ltd. 

No.  239,  Lane  202,  Chung  Cheng  W.  Road, 
Erh-Hang  Tsum,  Jen-Te  Hsiang 
Tainan  Hsien 
TAIWAN 

Contact:  Mr.  Zhi  Ming  Wang 
Phone:  886-6-2625343 
Fax:  886-6-2665439 


Fasteners  &  Metals 

Accreditation  Valid  Through:  March  31,  1999 
NVLAP 

Code  Designation 
Dimensional  Inspection 

External  thread  parameters  -  ISO 

FA/390      ISO  1502 

External  thread  parameters  -  system  21 

FA/379      ANSI/ASME  B1.3M 


NVLAP  1999  DIRECTORY  -  Page  D169 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Mechanical  and  Physical  Testing  and  Inspection 

Axial  tensile  strength  of full-size  threaded  fasteners 

FA/266       ASTM  F606  Sec.  3.4. 1-3.4.3 
FA/267       ASTM  F606M  Sec.  3.4.1-3.4.3 
Measurement  of  fastener  coating  thickness  -  coulometric 
method 

FA/567      ASTM  B504 
Microhardness  of  fasteners 

FA/ 189       ASTM  E3  84 

Proof  load  of full-size  externally  threaded  fasteners 

FA/226      ASTM  F606  Sec.  3.2.1-3.2.3 

FA/467      ASTM  F606M  Sec.  3.2. 1-3.2.3 

Rockwell  hardness  of  fasteners 

FA/ 197      ASTM  El 8 

Rockwell  superficial  hardness  of  fasteners 

FA/205       ASTM  El 8 

Torque-tension  of  full-size  threaded  fasteners 

FA/938       ASTM  F9 12 
FA/939      ASTM  F912M 

Total  extension  at  fracture  of  externally  threaded 
fasteners 

FA/285       ASTM  F606  Sec.  3.7 

FA/286      ASTM  F606M  Sec.  3.7 

Wedge  tensile  strength  of  full-size  threaded  fasteners 

FA/290      ASTM  F606  Sec.  3.5 

FA/291       ASTM  F606M  Sec.  3.5 

Yield  strength  of  full-size  externally  threaded  fasteners 

FA/298       ASTM  F606  Sec.  3.2.4 

FA/300      ASTM  F606M  Sec.  3.2.4 

Metallography 

Decarburization  and  case  depth  measurement  in 
fasteners 

FA/325       ISO  898-5 
FA/867      ASTM  F9 12 

Surface  discontinuities  of  externally  threaded  fasteners 

FA/357       ASTM  F788/788M 

NVLAP  LAB  CODE  200287-0 
Small  IAC  Test  Laboratory 

107  Park  St.  N 
Peterborough,  ON  K9J-7B5 
CANADA 

Contact:  Mr.  Harold  Peltzer 
Phone:  705-748-7343 
Fax:  705-748-7677 

E-Mail:  Peltzer.harold@mlink.motors.ge.com 

Efficiency  of  Electric  Motors 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 
24/M01       IEEE  112,  Method  B 


NVLAP  LAB  CODE  200288-0 
Fong  Prean  Industrial  Co.,  Ltd. 

No.  6  Kung-Wei  St.  Tzu  Hsin  T'Sun 
Tzu  Kuan  Hsiang 
Kaohsiung  Hsien 
TAIWAN 

Contact:  Mr.  Chang  San  Tien 
Phone:  886-7-6170526 
Fax:  886-7-6103160 


Fasteners  &  Metals 

Accreditation  Valid  Through:  March  31,  1999 

NVLAP 

Code  Designation 
Dimensional  Inspection 

Dimensions  of  general  purpose  fasteners  and 
high-volume  machine  assembly  fasteners 

FA/854      ANSI/ASMEB1 8.6.4 
FA/855       ISO  1479 

Mechanical  and  Physical  Testing  and  Inspection 

Drill-drive  test 

FA/247       SAE  J78 
FA/851       DIN  7504 
Hardness  preparation 

FA/464      ASTM  F606M 
FA/482       ASTM  F606 

Measurement  of  fastener  coating  thickness  -  X-ray 
methods 

FA/760      ASTM  A754/A754M 

Microhardness  of  fasteners 

FA/189  ASTME384 

Rockwell  hardness  of  fasteners 

FA/ 197      ASTM  El 8 

Rockwell  superficial  hardness  of  fasteners 

FA/205       ASTM  El 8 

Salt  spray  testing  of  fasteners 

FA/166      ASTM  Bl  17 

Torsional  strength  test  of  thread  rolling  and  self-drilling 
tappings  screws 
FA/751  SAEJ933 
FA/852      ISO  2702 
FA/853       DIN  7504 

Metallography 

Decarburization  and  case  depth  measurement  in 
fasteners 

FA/330       SAE  J423 
FA/562       ASTM  G79 

Surface  discontinuities  of  externally  threaded  fasteners 

FA/357       ASTM  F788/788M 
FA/361  SAEJ123 


NVLAP  1999  DIRECTORY  -  Page  D170 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  200289-0 
Craig  Environmental  Services,  Inc. 

5439  Harding  Highway 

P.O.  Box  427 

Mays  Landing,  NJ  08330 

Contact:  Ms.  Hollie  A.  Madamba 

Phone:  609-625-4200 

Fax:  609-625-1798 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  200290-0 

ATC  Associates  Inc. 

11356  Mathis  Ave. 
Dallas,  TX  75229-3157 
Contact:  Ms.  Cynthia  E.  Watkins 
Phone:  972-556-2205 
Fax:  972-556-1753 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  200291-0 
NGC  Testing  Services,  National  Gypsum 
Research  Center 

1650  Military  Road 
Buffalo,  NY  14217-1198 
Contact:  Mr.  Robert  J.  Menchetti 
Phone:  716-873-9750 
Fax:  716-873-9753 
E-Mail:  ngctest@buffhet.net 

URL:  http://www.national-gypsum.com/testing/index.html 

Acoustical  Testing  Services 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

08/P03       ASTM  C423  (ISO  354) 
08/P06       ASTM  E90  (ISO  140,  Part  3) 
08/P30       ASTM  E1408 

08/P34       ASTM  E1414  (AMA-l-II-67)(ISO  140,  Part  9) 
NVLAP  LAB  CODE  200292-0 
BCAG  Fastener  Quality  Test  Lab  Everett  Site 
P.O.  Box  370,  MS  04-02 
Seattle,  WA  98124-2207 
Contact:  Mr.  Eugene  J.  Brown 
Phone:  425-342-3888 
Fax:  425-266-4673 
E-Mail:  eugene.j.brown@boeing.com 

Fasteners  &  Metals 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 


Chemical  Analysis 

Combustion  analysis  for  carbon,  sulfur,  oxygen, 
nitrogen,  and  hydrogen 

FA/472      ASTM  El 447 

Optical  emission  spectro chemical  analysis 

FA/456      ASTM  E327 

FA/457      ASTM  E4 15 

FA/458      ASTM  E607 

FA/459      ASTM  El 086 

FA/460      ASTM  El 251 

Spot  test  analysis 

FB/1076  Dl-8018-2 

Dimensional  Inspection 

Dimensions  of  fasteners  -  bearing  surface  squareness 
FA/911  BPS-N-70 

Dimensions  of  fasteners  -  gaging  for  slotted  nuts 

FA/417      ANSI/ASMEB  18.2.2 
FA/418  ANSI/ASMEB18.2.4.3M 
Dimensions  of  fasteners  -  straightness 
FA/423       ANSI/ASMEB  18.2.1 

Dimensions  of  special  purpose  fasteners  and  fasteners  for 
highly  specialized  engineered  ap 


FA/405 

ANSI/ASMEB18.18.3M 

FA/406 

ANSI/ASMEB18.18.4M 

FB/1060 

BPS-F-69 

FB/1061 

BPS-F-76 

FB/1062 

BPS-F-67 

FB/1063 

D- 11 805 

FB/1064 

BPS-N-70 

FB/1065 

BPS-F-68 

External  thread  parameters  -  system  22 

FA/381 

ANSI/ASMEB  1.3M 

FA/382 

FED-STD-H28/20 

FA/383 

MIL-S-7742 

FA/384 

MIL-S-8879 

Internal  thread  parameters  -  system  21 

FA/391 

ANSI/ASME  B1.3M 

FA/392 

FED-STD-H28/20 

FA/529 

MIL-S-7742 

Surface  texture 

FA/439      ANSI/ASME  B46.1 


Mechanical  and  Physical  Testing  and  Inspection 

Adhesion  of  metallic  coatings  on  fasteners 

FA/532      BMS  10-85M  Sec.  8.2 

Axial  tensile  strength  of full-size  threaded  fasteners 

FA/271  MIL-STD-1312-8 

FA/799      NASM  1312-8 

FB/1067  D2-2860 

Double  shear  of  externally  threaded  fasteners 

FA/257  MIL-STD-1312-13 

FA/880      NASM  1312-13 

FB/1066  D2-2860 

FB/1070  NAS498 

Fatigue  of full-size  threaded  fasteners 

FA/183  MIL-STD-1312-11 

FA/184      NAS  1069 

FA/876      NASM  1312-11 


NVLAP  1999  DIRECTORY  -  Page  D171 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


FB/1038  D2-2860 
Hardness  preparation 

FB/1071  NAS498 

Hydrogen  embrittlement  (stress  durability)  of  externally 

threaded  fasteners 

FA/176  MIL-STD-1312-5 

FA/801  QQ-P-416 

FA/875       NASM  1312-5 

Hydrogen  embrittlement  (stress  durability)  of  internally 

threaded  fasteners 

FA/178       MIL-STD-13 12-14 

FA/800  QQ-P-416 

FB/1033     NASM  1312-14 

Intergranular  corrosion  susceptibility  of  austentic 
stabiles  steel  fasteners  -  oxalic  acid 

FA/ 1 74       ASTM  A262  Sec.  3-7,  Practice  A 

Measurement  of  fastener  coating  thickness  -  dimensional 

change  method 

FA/495       MIL-STD-13 12-12 

FA/874       NASM  1312-12 

Measurement  of  fastener  coating  thickness  - 

microscopical  method 

FA/ 160  ASTMB487 

FA/ 163       MIL-STD-13 12-12 

FA/873       NASM  1312-12 

Microhardness  of  fasteners 

FA/189  ASTME384 

Prevailing  torque 

FA/630  MIL-N-25027 

FA/899  BPS-N-70 

FA/902       NAS  3350 

Proof  load  of full-size  externally  threaded  fasteners 
FA/691       MIL-STD-13 12-8 
FB/1037     NASM  1312-8 
FB/1041  D2-2860 

Proof  load  of  internally  threaded  fasteners  (nuts) 
FB/1039     MIL-STD-13 12-8 
FB/1040     NASM  1312-8 
FB/1042  D2-2860 

Push  out  test  of  floating  plate  nuts,  gang  channel  nuts, 
and  anchor  nuts 

FA/116  MIL-N-25027 
FA/891  BPS-N-70 

Recess  strength  test  in  both  the  installation  and  removal 
directions 

FA/886      NASM  1312-25 

Reusability  test  of  self-locking  internally  threaded 
fasteners 

FA/124  MIL-N-25027 
FA/125       NAS  3350 
FA/774  BPS-N-70 
Rockwell  hardness  of  fasteners 
FA/196       ASTM  A370  Sec.  18 
FA/197       ASTM  El 8 
FA/201       MIL-STD-13 12-6 
FA/878      NASM  1312-6 
FB/1072     BAC  5650 


Rockwell  superficial  hardness  of  fasteners 

FA/205       ASTM  El  8 
FA/206      ASTM  A370  Sec.  18 
FA/209      MIL-STD-13 12-6 
FB/1035     NASM  1312-6 
Salt  spray  testing  of  fasteners 
FA/168       MIL-STD-13 12-1 
FB/1032     NASM  1312-1 

Tension  testing  of  machined  specimens  from  externally 
threaded  fasteners 

FA/475       ASTM  E8 
FB/1043  ASTMB557 

Test  for  embrittlement  of  metallic  coated  externally 

threaded  fasteners 

FA/525  MIL-STD-1312-5 

FB/1034     NASM  1312-5 

Torque-out  test 

FA/133  MIL-N-25027 

FB/1031  BPS-N-70 

Vickers  hardness  -  test  forces  from  9.807  to  11 76  N  (1  to 
120  kgf) 

FA/671       MIL-STD-13 12-6 
FB/1036     NASM  1312-6 

Wedge  tensile  strength  of full-size  threaded  fasteners 
FA/295       MIL-STD-13 12-8 
FB/1044     NASM  1312-8 
FB/1069  D2-2860 

Wrench  torque  test  of  externally  wrenched  nuts  of  spline 
and  hexagon  and  double  hexagon  (1 

FA/141  MIL-N-25027 
FA/142      NAS  3350 
FA/893  BPS-N-70 

Yield  strength  of full-size  externally  threaded  fasteners 
FA/303       MIL-STD-13 12-8 
FB/1045     NASM  1312-8 
FB/1068  D2-2860 

Metallography 

Decarburization  and  case  depth  measurement  in 
fasteners 

FA/323       ASTM  E1077 

FA/904  BPS-N-70 

FB/1046  BPS-F-76 

FB/1047  BPS-F-67 

FB/1048     NAS  498 

FB/1073  BPS-F-46 

Determination  of  grain  size  of fasteners 

FA/331       ASTM  El  12 

Macroscopic  examination  of  fasteners  by  etching 

FA/5 1 1       ASTM  E340 

Microscopic  examination  of  fasteners  by  etching 

FA/512  ASTME407 

Surface  discontinuities  of  externally  threaded  fasteners 

FA/357       ASTM  F788/788M 
FA/859       ASTM  A574 
FB/1049     NAS  4002 
FB/1050     NAS  4003 
FB/1051     NAS  4004 
FB/1052  BPS-F-67 


NVLAP  1999  DIRECTORY  -  Page  D172 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


FB/1053  BPS-F-69 
FB/1054  BPS-F-68 
FB/1055  BPS-F-76 
FB/1056  NAS498 
FB/1057  FF-S-86 

Surface  discontinuities  of  internally  threaded  fasteners 
FA/907  BPS-N-70 
Nondestructive  Inspection 

Liquid  penetrant  inspection  of  fasteners 

FA/527      ASTM  E1417 

FB/1059  MIL-I-25135 

FB/1074     B AC  5423 

Magnetic  particle  inspection  of  fasteners 

FA/485       ASTM  El 444 

FB/1075  BAC5424  

NVLAP  LAB  CODE  200293-0 
EMSL  Analytical,  Inc. 

10766  Rhode  Island  Avenue 
Beltsville,  MD  20705 
Contact:  Mr.  Joseph  Centifonti 
Phone:  301-937-5700 
Fax:  301-937-5702 

URL:  http://www.emsl.com 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  December  31,  1999 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  December  31,  1999 


NVLAP  LAB  CODE  200294-0 
Micron  Environmental  Labs 

292  E.  Foothill  Blvd.,  Suite  B 
Arcadia,  CA  91006 
Contact:  Mr.  Daniel  Gamez 
Phone:  626-357-8627 
Fax:  626-256-9017 


Dimensions  of  general  purpose  fasteners  and 
high-volume  machine  assembly  fasteners 
FA/607      JIS  B1071 

Mechanical  and  Physical  Testing  and  Inspection 

Axial  tensile  strength  of full-size  threaded  fasteners 

FA/574      JIS  B1051  Sec.  4.2.2 

Measurement  of  fastener  coating  thickness  -  magnetic 

methods 

FA/596  JISH8501 

Proof  load  of full-size  externally  threaded  fasteners 

FA/573       JIS  B 1051  Sec.  4.2.4 

Rockwell  hardness  of  fasteners 

FA/572      JIS  Z2245 

FA/616      JISB1051  Sec.  4.3 

FA/707      JIS  B 1051  Sec.  4.2.5 

Salt  spray  testing  of  fasteners 

FA/569  JISZ2371 

Vickers  hardness  -  test  forces  from  9.807  to  11 76  N  (1  to 
120  kgf) 

FA/571  JISZ2244 

FA/643       JIS  B 1051  Sec.  4.2.5 

Metallography 

Decarburization  and  case  depth  measurement  in 
fasteners 

FA/645       JIS  B 1051 

Surface  discontinuities  of  externally  threaded  fasteners 

FA/646      JIS  B 1041  

NVLAP  LAB  CODE  200297-0 
Intertek  Testing  Services  NA  Inc. 

2761 1  La  Paz  Road,  Suite  C 
Laguna  Niguel,  CA  92677 
Contact:  Mr.  Simon  Rate 
Phone:  714-448-4100 
Fax:  714-448-4111 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  December  31,1 999 


NVLAP  LAB  CODE  200296-0 

Okawa  Laboratory 

6357-1  Oba,  Omiya-cho 
Naka-gun,  Ibaraki-ken  319-21 
JAPAN 

Contact:  Mr.  Katsuyoshi  Okawa 
Phone:  81-2955-3-0111 
Fax:  81-2955-3-5290 


Fasteners  &  Metals 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 
Dimensional  Inspection 


FCC  Test  Methods 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/F0 1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

12/F01a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
12/F01b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 


NVLAP  1999  DIRECTORY  -  Page  D173 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  200298-0 
SPS  Technologies  Aerospace  Product  Division 

2701  S.  Harbor  Boulevard 
Santa  Ana,  CA  92702-1259 
Contact:  Mr.  Rob  Dewitz 
Phone:  714-850-3664 
Fax:  714-850-3605 


Fasteners  &  Metals 

Accreditation  Valid  Through:  March  31,  1999 

NVLAP 

Code  Designation 
Dimensional  Inspection 

Dimensions  of  fasteners  -  bearing  surface  squareness 

FA/633  MIL-N-25027 

Dimensions  of  fasteners  -  hexagon  and  double  hexagon 

(12  point)  and  spline  sockets 

FA/411       ANSI/ASME  B18.3 

FA/540  MIL-STD-33787 

FA/634  MIL-STD-21132 

FA/635       SAE  AS  870 

Dimensions  of  fasteners  -  straightness 

FA/423       ANSI/ASME  B  18.2.1 

External  thread  parameters  -  system  21 

FA/379       ANSI/ASME  B1.3M 

FA/380  FED-STD-H28/20 

FA/628  MIL-S-8879 

External  thread  parameters  -  system  22 

FA/381       ANSI/ASME  B  1.3 M 

FA/382  FED-STD-H28/20 

FA/384  MIL-S-8879 

External  thread  parameters  -  system  23 

FA/385       ANSI/ASME  B1.3M 

FA/386  FED-STD-H28/20 

FA/388  MIL-S-8879 

Internal  thread  parameters  -  system  21 

FA/39 1       ANSI/ASME  B 1 .3M 

FA/392  FED-STD-H28/20 

FA/629  MIL-S-8879 

Internal  thread  parameters  -  system  22 

FA/393       ANSI/ASME  B1.3M 

FA/394  FED-STD-H28/20 

FA/537       SAE  AS  8879 

Surface  texture 

FA/439       ANSI/ASME  B46.1 

Mechanical  and  Physical  Testing  and  Inspection 

Adhesion  of  metallic  coatings  on  fasteners 

FA/143  ASTMB571 

Axial  tensile  strength  of full-size  threaded  fasteners 

FA/265       ASTM  A370  Sec.  A3. 2. 1 .4 
FA/266       ASTM  F606  Sec.  3.4. 1  -3.4.3 
FA/271  MIL-STD-1312-8 
Double  shear  of  externally  threaded  fasteners 
FA/257  MIL-STD-1312-13 


Hardness  preparation 

FA/482       ASTM  F606 

Humidity  testing  of  fasteners 

FA/169      MIL-STD-753  Test  Method  101 

FA/473  MIL-STD-1312-3 

FA/923       ASTM  A967 

Hydrogen  embrittlement  (stress  durability)  of  externally 

threaded  fasteners 

FA/176  MIL-STD-1312-5 

FA/924      ASTM  F606 

Hydrogen  embrittlement  (stress  durability)  of  internally 

threaded  fasteners 

FA/ 178  MIL-STD-1312-14 

Magnetic  permeability 

FA/2 1 4       ASTM  A342  Test  Method  3 

Measurement  of  fastener  coating  thickness  -  X-ray 

methods 

FA/556       ASTM  B568 

Measurement  of  fastener  coating  thickness  -  magnetic 
methods 

FA/153  ASTMB499 

FA/159  MIL-STD-1312-12 

Measurement  of  fastener  coating  thickness  - 

microscopical  method 

FA/160  ASTMB487 

FA/ 163  MIL-STD-1312-12 

Microhardness  of  fasteners 

FA/189  ASTME384 

FA/193  MIL-STD-1312-6 

Permanent  set  test  of  self-locking  nuts 

FA/ 109  MIL-N-25027 

Prevailing  torque 

FA/630  MIL-N-25027 

Proof  load  of full-size  externally  threaded  fasteners 

FA/226       ASTM  F606  Sec.  3.2.1-3.2.3 

Proof  load  of  internally  threaded  fasteners  (nuts) 

FA/236      ASTM  F606  Sec.  4.2 

Push  out  test  of  floating  plate  nuts,  gang  channel  nuts, 
and  anchor  nuts 

FA/926       SPS  316 

Recess  strength  test  in  both  the  installation  and  removal 
directions 

FA/476       MIL-STD-13 12-25 

Reusability  test  of  self-locking  internally  threaded 

fasteners 

FA/124  MIL-N-25027 
FA/522      MIL-STD-13 12-31 
Rockwell  hardness  of  fasteners 
FA/197      ASTM  El 8 
FA/201  MIL-STD-1312-6 
Rockwell  superficial  hardness  of  fasteners 
FA/205       ASTM  El 8 
FA/209  MIL-STD-1312-6 

Room  temperature  of  three  cycles  test  of  floating  plate 
nuts,  gang  channel  nuts  and  anchor 

FA/927       SPS  380 


NVLAP  1999  DIRECTORY  -  Page  D174 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Salt  spray  testing  of fasteners 

FA/166  ASTMB117 

FA/168  MIL-STD-1312-1 

Single  shear  of  externally  threaded  fasteners 

FA/255      ASTM  F606 

FA/256  MIL-STD-1312-20 

FA/925       ASTM  F606M 

Stress  rupture  of  fasteners 

FA/260      ASTM  El 39 

FA/261  ASTME292 

FA/262  MIL-STD-1312-10 

Tension  testing  of  machined  specimens  from  externally 
threaded  fasteners 

FA/278      ASTM  A370 
FA/279      ASTM  F606  Sec.  3.6 
FA/475       ASTM  E8 

Test  for  embrittlement  of  metallic  coated  externally 

threaded  fasteners 

FA/179      ASTM  F606  Sec.  7 

FA/525  MIL-STD-1312-5 

Torque-out  test 

FA/133  MIL-N-25027 

FA/523       MIL-STD-13 12-31 

Torque-tension  of full-size  threaded  fasteners 

FA/307      MIL-STD-13 12-15 

Vibration  of  full-size  threaded  fasteners 

FA/311       MIL-STD-13 12-7 

FA/631  MIL-N-25027 

Wedge  tensile  strength  of full-size  threaded  fasteners 

FA/289      ASTM  A3 70 

FA/290      ASTM  F606  Sec.  3.5 

Yield  strength  of  full-size  externally  threaded  fasteners 

FA/298      ASTM  F606  Sec.  3.2.4 
FA/299      ASTM  A370  Sec.  A3.2. 1.3(a) 

Metallography 

Decarburization  and  case  depth  measurement  in 
fasteners 

FA/323       ASTM  El  077 
Determination  of  grain  size  of fasteners 

FA/638       ASTM  El  12 

Macroscopic  examination  of  fasteners  by  etching 
FA/511  ASTME340 

Microscopic  examination  of  fasteners  by  etching 
FA/512  ASTME407 

Surface  discontinuities  of  externally  threaded  fasteners 

FA/357      ASTM  F788/788M 

Surface  discontinuities  of  internally  threaded  fasteners 
FA/865       ASTM  F8 1 2/F8 1 2M 
Nondestructive  Inspection 

Liquid  penetrant  inspection  of  fasteners 

FA/371  MIL-STD-6866 

FA/527      ASTM  E1417 

Magnetic  particle  inspection  of  fasteners 

FA/485       ASTM  El 444 


NVLAP  LAB  CODE  200299-0 
Okai  Iron  Works  Co.,  Ltd. 

3-12-41  Tsuruhara 
Izumisano  Osaka  598-0071 
JAPAN 

Contact:  Mr.  Yasuhiro  Okai 
Phone:  0724-63-6101 
Fax:  0724-63-6228 


Fasteners  &  Metals 

Accreditation  Valid  Through:  March  31,  1999 
NVLAP 

Code  Designation 
Dimensional  Inspection 

Dimensions  of  ISO  grade  A  and  B  fasteners 

FA/408       ISO  4759-1 
FA/930       ISO  4759-3 
Dimensions  of  ISO  grade  C  fasteners 
FA/410       ISO  4759-1 
FA/931       ISO  4759-3 

Dimensions  of  fasteners  -  bearing  surface  squareness 
FA/936       ISO  4759-1 

Dimensions  of  fasteners  -  flange  screw  heads  and  flange 
nuts 

FA/933  ISO  4161 
FA/934      ISO  4162 

Dimensions  of  fasteners  -  hexagon  and  double  hexagon 

(12  point)  and  spline  sockets 

FA/411       ANSI/ASME  B18.3 

FA/932      ISO  4759-1 

Dimensions  of  fasteners  -  straightness 

FA/935       ISO  4759-1 

External  thread  parameters  -  system  21 

FA/379      ANSI/ASME  B1.3M 

Internal  thread  parameters  -  system  21 

FA/391       ANSI/ASME  Bl. 3 M 

Surface  texture 

FA/937       ISO  4288 

Mechanical  and  Physical  Testing  and  Inspection 

Adhesion  of  metallic  coatings  on  fasteners 
FA/144      ISO  2819 

Axial  tensile  strength  of  full-size  threaded  fasteners 

FA/270      ISO  898-1  Sec.  8.2 

Measurement  of  fastener  coating  thickness  -  magnetic 
methods 

FA/153  ASTMB499 

Measurement  of  fastener  coating  thickness  - 

microscopical  method 

FA/ 162      ISO  1463 

Microhardness  of  fasteners 

FA/191       ISO  6507-2 

FA/192      ISO  6507-3 

Proof  load  of  full-size  externally  threaded  fasteners 
FA/228       ISO  898-1  Sec.  8.4 


NVLAP  1999  DIRECTORY  -  Page  D175 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Proof  load  of  internally  threaded  fasteners  (nuts) 

FA/239  ISO  898-2  Sec.  8.1 
Rockwell  hardness  of  fasteners 

FA/200      ISO  6508 

Tension  testing  of  machined  specimens  from  externally 
threaded  fasteners 
FA/282       ISO  898-1 

Total  extension  at  fracture  of  externally  threaded 
fasteners 

FA/287       ISO  3506 

Wedge  tensile  strength  of full-size  threaded  fasteners 
FA/294      ISO  898-1  Sec.  8.5 

Yield  strength  of full-size  externally  threaded  fasteners 
FA/298      ASTM  F606  Sec.  3.2.4 
Metallography 

Decarburization  and  case  depth  measurement  in 
fasteners 

FA/324  ISO  898-1 
FA/928       ISO  2639 

Macroscopic  examination  of  fasteners  by  etching 
FA/929      ISO  4969 

Surface  discontinuities  of  externally  threaded  fasteners 
FA/359       ISO  6157-1 
FA/360      ISO  6157-3 

Surface  discontinuities  of  internally  threaded  fasteners 

FA/727       ISO  6157-2 

NVLAP  LAB  CODE  200300-0 
Akzo  Kashima  Ltd.,  Kawasaki  Technical  Center 

5-23-13  Minamikase,  Saiwai-ku 

Kawasaki  2 1 1 

JAPAN 

Contact:  Mr.  Shuichi  Kobayashi 
Phone:  81-479-40-1097 
Fax:  81-479-46-1788 


FCC  Test  Methods 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/F0 1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

12/F01a      Conducted  Emissions,  Power  Lines,  450  KHz 
to  30  MHz 

1 2/FO 1  b      Radiated  Emissions 

12/T01       Terminal  Equipment  Network  Protection 

Standards,  FCC  Method  -  47  CFR  Part  68  - 
Analog  and  Digital 

12/T01a      68.302  (Par.  c,d,e,f)  Environmental  simulation; 
68.304  Leakage  current  limit.;  68.306 
Hazardous  voltage  limit.;  68.308  Signal  power 
limit.;  68.310  Longitudinal  balance  limit.; 


68.312  On-hook  impedance  limit.;  68.314 
Billing  protection 
12/T01b     68.316  Hearing  Aid  Compatibility:  technical 
standards 

12/T01c      68.302  Environmental  simulation  (Par.  a,b) 
International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

1 2/CIS22    IEC/CISPR  22: 1 993 :  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200303-0 

A.E.S.L. 

800  North  Mary  Street 
Tempe,AZ  85281-1945 
Contact:  Mr.  Kenneth  W.  Hokanson 
Phone:  602-966-7171 
Fax:  602-394-0188 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  200304-0 
GEC  Marconi  Avionics  Ltd  Environmental  and 
EMC  Test  Center 

Airport  Works 

Rochester 

Kent  ME  1  2XX 

UNITED  KINGDOM 

Contact:  Mr.  Frank  Ewen 

Phone:  01-634-816794 

Fax:  01-634-816647 

E-Mail:  frank.ewen@gecm.com 

MIL-STD-462  Test  Methods 

Accreditation  Valid  Through:  March  31,  1999 
NVLAP 

Code  Designation 

Conducted  Emissions: 

1 2/A06       MIL-STD-462  Method  CE03 

1 2/A 1 2       MIL-STD-462  Method  CE07 

Conducted  Susceptibility: 

1 2/BO 1       MIL-STD-462  Method  CS0 1 

1 2/B02       MIL-STD-462  Method  CS02 

1 2/B05       MIL-STD-462  Method  CS06 

Radiated  Emissions: 

1 2/D02       MIL-STD-462  Method  RE02 

Radiated  Susceptibility: 

1 2/E02       MIL-STD-462  Method  RS02 

1 2/E03       MIL-STD-462  Method  RS03  (Consult 

laboratory  for  field  strengths  available) 
12/E04       MIL-STD-462  Method  RS03  employing 

RADHAZ  procedures  for  high  level  testing 


NVLAP  1999  DIRECTORY  -  Page  D176 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


(Consult  laboratory  for  field  strengths 
available) 

NVLAP  LAB  CODE  200305-0 
GE  Owensboro  Test  Laboratory 

3301  Old  Hartford  Road 
Owensboro,  KY  42718 
Contact:  Mr.  Robert  Riley 
Phone:  502-686-1212 
Fax:  502-686-1240 


Efficiency  of  Electric  Motors 

Accreditation  Valid  Through:  March  31,  1999 
NVLAP 

Code  Designation 

24/MO 1      IEEE  112,  Method  B 

NVLAP  LAB  CODE  200306-0 
Zacta  Technology  Corporation  Yonezawa  Testing 
Center 

4149-7  Hachimanpara  5-chome 
Yonezawa-shi  Yamagata  992-1 128 
JAPAN 

Contact:  Mr.  Shin-ichi  Abe 

Phone:  81-238-28-2880 

Fax:  81-238-28-2888 

E-Mail:  albatross_abe@hi-ho.ne.jp 

FCC  Test  Methods 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/F0 1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO 1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  1  b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

1 2/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 


NVLAP  LAB  CODE  200307-0 

Rocknel  Fastener  Inc. 

5309  1  1th  Street 
Rockford,  IL  61125-7009 
Contact:  Mr.  White  White 
Phone:  815-873-4048 
Fax:  815-873-4011 


Fasteners  &  Metals 

Accreditation  Valid  Through:  March  31,1 999 
NVLAP 

Code  Designation 
Dimensional  Inspection 

Dimensions  of  fasteners  -  flange  screw  heads  and  flange 
nuts 

FA/690  JISB1071 

Dimensions  of  fasteners  -  straightness 

FA/648  JISB1071 

Dimensions  of  general  purpose  fasteners  and 

high-volume  machine  assembly  fasteners 

FA/404  ANSI/ASMEB18.18.2M 

FA/607  JISB1071 

External  thread  parameters  -  ISO 

FA/624      JIS  B0252 

FA/884  JISB0251 

External  thread  parameters  -  system  21 

FA/379      ANSI/ASME  B1.3M 

External  thread  parameters  -  system  22 

FA/381       ANSI/ASME  B1.3M 

Mechanical  and  Physical  Testing  and  Inspection 

Adhesion  of  metallic  coatings  on  fasteners 
FA/143  ASTMB571 
FA/595       JIS  H8504 

Axial  tensile  strength  of full-size  threaded  fasteners 

FA/267      ASTM  F606M  Sec.  3.4.1-3.4.3 
FA/270      ISO  898-1  Sec.  8.2 
FA/574      JIS  B 1051  Sec.  4.2.2 
Hardness  preparation 
FA/464      ASTM  F606M 

Measurement  of  fastener  coating  thickness  -  eddy-current 
method 

FA/618  JISH8501 
Microhardness  of  fasteners 

FA/189  ASTME384 

Proof  load  of full-size  externally  threaded  fasteners 

FA/228       ISO  898-1  Sec.  8.4 

FA/467      ASTM  F606M  Sec.  3.2.1-3.2.3 

FA/573       JIS  B1051  Sec.  4.2.4 

Rockwell  hardness  of  fasteners 

FA/572      JIS  Z2245 

Rockwell  superficial  hardness  of  fasteners 

FA/205       ASTM  El 8 


NVLAP  1999  DIRECTORY  -  Page  D177 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Total  extension  at  fracture  of  externally  threaded 
fasteners 

FA/286       ASTM  F606M  Sec.  3.7 

Vickers  hardness  -  test  forces  from  9.807  to  1176  N  (1  to 

UOkgf) 

FA/571  JISZ2244 

Wedge  tensile  strength  of full-size  threaded  fasteners 

FA/291       ASTM  F606M  Sec.  3.5 
FA/294       ISO  898-1  Sec.  8.5 
FA/575       JISB 1051  Sec.  4.2.3 

Yield  strength  of  full-size  externally  threaded  fasteners 

FA/300       ASTM  F606M  Sec.  3.2.4 
FA/686      JISB1051  Sec.  4.2.2 
FA/885       ISO  6892 

Metallography 

Decarburization  and  case  depth  measurement  in 
fasteners 

FA/324       ISO  898-1 

Surface  discontinuities  of  externally  threaded  fasteners 

FA/359       ISO  6157-1  

[NfVLAP  LAB  CODE  200308-0 

SNB  Laboratory 

49  Abbott  Street 
P.O.  Box  68 

Cumberland,  RI  02864-0968 
Contact:  Mr.  James  Faria 
Phone:  401-722-6700 
Fax:  401-726-4960 


Fasteners  &  Metals 

Accreditation  Valid  Through:  March  31,  1999 
NVLAP 

Code  Designation 
Dimensional  Inspection 

Dimensions  of  fasteners  -  hearing  surface  squareness 

FA/745       ANSI  B 18. 2.1 

Dimensions  of  fasteners  -  straightness 

FA/423       ANSI/ASMEB1 8.2.1 

Dimensions  of  general  purpose  fasteners  and 

high-volume  machine  assembly  fasteners 

FA/486       MIL-STD-120  (W/  Notice  dtd  9  SEP  63) 

External  thread  parameters  -  system  21 

FA/379  ANSI/ASMEB1.3M 

FA/940      ANSI/ASME  B1.2 

External  thread  parameters  -  system  22 

FA/381       ANSI/ASME  B1.3M 

FA/941       ANSI/ASME  B  1.2 

Internal  thread  parameters  -  system  21 

FA/39 1       ANSI/ASME  BUM 

FA/942       ANSI/ASME  B  1.2 

Internal  thread  parameters  -  system  22 

FA/393       ANSI/ASME  BUM 

FA/943       ANSI/ASME  B  1.2 

Mechanical  and  Physical  Testing  and  Inspection 


Axial  tensile  strength  of full-size  threaded  fasteners 

FA/265       ASTM  A370  Sec.  A3. 2. 1 .4 
FA/266      ASTM  F606  Sec.  3.4.1-3.4.3 
FA/273       SAE  J429 

Cone  proof  load  of  internally  threaded  fasteners  (nuts) 

FA/220      ASTM  F606  Sec.  4.3 

Magnetic  permeability 

FA/2 1 4      ASTM  A342  Test  Method  3 

Proof  load  of  full-size  externally  threaded  fasteners 

FA/226      ASTM  F606  Sec.  3.2.1-3.2.3 

FA/229       SAE  J429  Sec.  5.3 

Proof  load  of  internally  threaded  fasteners  (nuts) 

FA/236       ASTM  F606  Sec.  4.2 

Rockwell  hardness  of  fasteners 

FA/ 197       ASTM  El 8 

Tension  testing  of  machined  specimens  from  externally 

threaded  fasteners 

FA/278       ASTM  A3  70 

FA/279       ASTM  F606  Sec.  3.6 

Wedge  tensile  strength  of full-size  threaded  fasteners 

FA/289       ASTM  A370 

FA/290      ASTM  F606  Sec.  3.5 

Yield  strength  of full-size  externally  threaded  fasteners 

FA/298      ASTM  F606  Sec.  3.2.4 

NVLAP  LAB  CODE  200309-0 
TDK  Corporation's  10m  Anechoic  Chamber  and 
Chikumagawa  Open  Site 
2-15-7  Higashi-Owada 
Ichikawa-shi,  Chiba-ken  272 
JAPAN 

Contact:  Mr.  Akira  Bandoh 
Phone:  011-81-47-378-9190 
Fax:  011-81-47-378-9780 
E-Mail:  HFE00246@niftyserve.or.jp 

FCC  Test  Methods 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 

Devices 

1 2/FO  1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(C1SPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 


NVLAP  1999  DIRECTORY  -  Page  D178 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  200310-0 
EMSL  Analytical,  Inc. 

700  Gotham  Parkway 
Carlstadt,  NJ  07072 
Contact:  Ms.  Gael  E.  Miller 
Phone:  201-531-2666 
Fax:  201-531-1769 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  March  31,  1999 


Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  March  31,  1999 


NVLAP  LAB  CODE  200312-0 
Sony  Electronics  Inc.  Product  Quality  Division 
EMC  Group 

16450  West  Bernardo  Drive,  Building  8 
San  Diego,  CA  92127-1804 
Contact:  Mr.  Dave  Traver 
Phone:  619-673-2601 
Fax:  619-674-5967 


FCC  Test  Methods 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/F0 1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

12/F01a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
12/F01b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

1 2/CIS22    IEC/CISPR  22: 1 993 :  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 


NVLAP  LAB  CODE  200313-0 
Eastman  Kodak  Co.-Regulatory  Compliance 
Center-EMC  Facility 

901  Elmgrove  Road 
Rochester,  NY  14653-5513 
Contact:  Ms.  Gina  T.  Wyffels 
Phone:  716-726-3200 
Fax:  716-726-4297 

E-Mail:  2340 1 0n@isbpgate.kodak.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

1 2/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200314-0 
MQS  Inspection,  Inc.  Magnetic  Particle  &  Liquid 
Penetrant  Exam. 

9910  Jordan  Circle 

Santa  Fe  Springs,  CA  90670 

Contact:  Mr.  Stephen  R.  Mesko 

Phone:  562-944-8511 

Fax:  562-9606-0331 


Fasteners  &  Metals 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Nondestructive  Inspection 

Liquid  penetrant  inspection  of fasteners 
FA/527  ASTME1417 
Magnetic  particle  inspection  of  fasteners 
FA/485       ASTM  El 444 


NVLAP  1999  DIRECTORY  -  Page  D179 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  200316-0 

ASC  geoscience,  inc. 

3055  Drane  Field  Road 
Lakeland,  FL  3381  1-1332 
Contact:  Mr.  Anu  Saxena,  P.E. 
Phone:  941-644-8300 
Fax:  941-644-8203 


Construction  Materials  Testing 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 
Aggregates 

02/A03       ASTM  C29 
02/A07       ASTM  CI  17 
02/A09       ASTM  CI 27 
02/A12       ASTM  CI 36 
Concrete 

02/A01  ASTMC39 
02/A02       ASTM  C6 17 
02/A40       ASTM  C78 
02/A43       ASTM  CI 064 
02/A45       ASTM  C42 

02/GO 1       ASTM  C3 1  /C 1 72/C 143/C 1 3 8/C23 1 

02/G02       ASTM  CI 73 

Road  and  Paving  Materials 

02/M07      ASTM  D546 

02/M08      ASTM  D979 

02/M19      ASTM  D2 172 

02/M24      ASTM  D2041 

Soil  and  Rock 

02/L04       ASTM  D698 

02/L06       ASTM  Dl  140 

02/L07       ASTM  D 1556 

02/L08       ASTM  D 1557 

02/L12       ASTM  D2 168 

02/L20       ASTM  D43 1 8 

02/L23       ASTM  D2922 

02/L25       ASTM  D3017 

Standard  Practices 

02/M26      ASTM  D3666 

NVLAP  LAB  CODE  200317-0 
Raytheon  Technical  Services  Co.  EMI  Laboratory 
6125  E.  21st  Street,  M/S  60 
Indianapolis,  IN  46219-2058 
Contact:  Mr.  Keith  Hines 
Phone:  317-306-7484 
Fax: 317-306-3690 


MIL-STD-462  Test  Methods 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

Conducted  Emissions: 

1 2/A06       MIL-STD-462  Method  CE03 


Conducted  Susceptibility: 
1 2/B0 1       MIL-STD-462  Method  CS0 1 
1 2/B02       MIL-STD-462  Method  CS02 
1 2/B05       MIL-STD-462  Method  CS06 
Radiated  Emissions: 
1 2/D02       MIL-STD-462  Method  RE02 
Radiated  Susceptibility: 
1 2/E02       MIL-STD-462  Method  RS02 
1 2/E03       MIL-STD-462  Method  RS03  (Consult 
laboratory  for  field  strengths  available) 

NVLAP  LAB  CODE  200318-0 
Motorola  PPG  Compliance  Laboratory 
1500  Gateway  Boulevard,  M/S  75 
Boynton  Beach,  FL  33426 
Contact:  Mr.  Mac  Elliott,  III 
Phone:  561-739-3792 
Fax: 561-739-2341 
E-Mail:  FME001@email.met.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Federal  Communications  Commission  (FCC)  Methods 
1 2/F0 1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

12/F01b      Radiated  Emissions 

NVLAP  LAB  CODE  200319-0 
TDK  Corporation's  Chikumagawa  Open  Site 

543  Otai 

Saku-shi,  Nagano-ken  389-0209 
JAPAN 

Contact:  Mr.  Akira  Bandoh 
Phone:  011-81-47-378-9190 
Fax:  011-81-47-378-9780 
E-Mail:  HFE00246@niftfyserve.or.jp 

FCC  Test  Methods 

Accreditation  Valid  Through:  June  30,  1999 

NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  1  b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR22T993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 


NVLAP  1999  DIRECTORY  -  Page  D180 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  200320-0 
Modern  Plating  Corporation 

P.O.  Box  838,  South  Hancock  Avenue 
Freeport,  IL  61032-0838 
Contact:  Mr.  Daniel  James  Mauer 
Phone:  815-235-3111 
Fax:  815-235-4571 


Fasteners  &  Metals 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 
Chemical  Analysis 

Solution  chemical  analysis 

FA/969      MFC  AA  Work  Instructions 

Dimensional  Inspection 

Dimensions  of  general  purpose  fasteners  and 

high-volume  machine  assembly  fasteners 

FA/404  ANSI/ASMEB18.18.2M 

Dimensions  of  special  purpose  fasteners  and  fasteners  for 

highly  specialized  engineered  ap 

FA/405       ANSI/ASME  B 1 8. 1 8.3 M 

FA/406      ANSI/ASME  Bl  8. 18.4M 

Mechanical  and  Physical  Testing  and  Inspection 

Adhesion  of  metallic  coatings  on  fasteners 
FA/143  ASTMB571 

Measurement  of  fastener  coating  thickness  -  X-ray 
methods 

FA/556      ASTM  B568 

Measurement  of  fastener  coating  thickness  -  eddy-current 
method 

FA/148       ASTM  B244 

Measurement  of  fastener  coating  thickness  -  magnetic 
methods 

FA/153  ASTMB499 

Measurement  of  fastener  coating  thickness  -  weight  of 
coating 

FA/970      MPC  Coating  Weight  Work  Instructions 
Salt  spray  testing  of  fasteners 
FA/166      ASTM  Bl  17 

NVLAP  LAB  CODE  200321-0 
Binder  Metal  Products,  Inc. 

14909  South  Broadway 
Gardena,  CA  90248 
Contact:  Mr.  Bill  Weber 
Phone:  213-321-4835 
Fax:  310-532-2936 


Fasteners  &  Metals 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

Dimensional  Inspection 

Dimensions  of  fasteners  -  flatness 
FA/975       ASME  Y14.5M 
FA/976      Binder  QAI  0007 

Mechanical  and  Physical  Testing  and  Inspection 

Hardness  preparation 

FA/482      ASTM  F606 

Measurement  of  fastener  coating  thickness  -  eddy-current 
method 

FA/977      Binder  QAI  0005 
Rockwell  hardness  of  fasteners 

FA/197      ASTM  El 8 

FA/978       Binder  QAI  0006  

NVLAP  LAB  CODE  200323-0 

ALAC 

810  Pelham  Pkwy.  South,  Suite  5F 

Bronx,  NY  10462 

Contact:  Mr.  Aleksandr  Knobel 

Phone:  718-828-1308 

Fax:  718-239-2896 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  200324-0 

Clark  Seif  Clark,  Inc. 

21732  Devonshire  Street,  2nd  Floor 
Chatsworth,  CA  91311 
Contact:  Mr.  Christian  Goerrissen 
Phone:  818-727-2553 
Fax:  818-727-2556 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  December  31,  1999 


NVLAP  LAB  CODE  200325-0 

TEC-AN,  Inc. 

3535  N.W.  58th  Street,  Suite  470E 
Oklahoma  City,  OK  73112 
Contact:  Mr.  Donald  J.  Nist 
Phone:  405-943-3358 
Fax:  405-943-0363 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  1999  DIRECTORY  -  Page  D181 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  200326-0 
Hadd-Co  Inspection  Lab 

2420  Amsler  Street 
Torrance,  CA  90505-5302 
Contact:  Mr.  George  Haddad 
Phone:  310-325-7620 
Fax:  310-325-9655 


Fasteners  &  Metals 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 
Nondestructive  Inspection 

Liquid  penetrant  inspection  of fasteners 

FA/366      AMS  2645 

FA/370  MIL-STD-271 

FA/371  MIL-STD-6866 

FA/527       ASTM  E1417 

FA/987       ASTM  E1208 

FA/988       ASTM  El 209 

FA/989  MIL-I-6866 

Magnetic  particle  inspection  of  fasteners 

FA/374       ASTM  E709 

FA/376  MIL-STD-271 

FA/377  MIL-STD-1949 

FA/485       ASTM  El 444 

FA/990  MIL-I-6868 

NVLAP  LAB  CODE  200327-0 

Saturn  Fasteners,  Inc. 

425  South  Varney  Street 
Burbank,  CA  91502 
Contact:  Mr.  Robert  P.  Whitley 
Phone:  818-846-7145 
Fax:  818-846-7306 


Fasteners  &  Metals 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 
Dimensional  Inspection 

Dimensions  of  fasteners  -  hexagon  and  double  hexagon 
(12  point)  and  spline  sockets 

FA/972      NAS  4002 
FA/973       NAS  624-644 
Dimensions  of  fasteners  -  straightness 

FA/974      NAS  4002 

External  thread  parameters  -  SAE  fastener  with  MJ 

metric  screw  threads 

FA/693  FED-STD-H28/20 

External  thread  parameters  -  system  21 

FA/380  FED-STD-H28/20 

External  thread  parameters  -  system  22 

FA/382  FED-STD-H28/20 


External  thread  parameters  -  system  23 
FA/386  FED-STD-H28/20 
Surface  texture 

FA/439      ANSI/ASME  B46.1 

Mechanical  and  Physical  Testing  and  Inspection 

Bend  test  of  full  size  eyebolts 

FA/971       MIL-B-6812  Section  4.5.4 

Breaking  strength  of  fullsize  eyebolts 

FA/508  MIL-STD-1312-8 

Double  shear  of  externally  threaded  fasteners 

FA/257      MIL-STD-13 12-13 

Fatigue  of  full-size  threaded  fasteners 

FA/183       MIL-STD-13 12-11 

Hydrogen  embrittlement  (stress  durability)  of  externally 

threaded  fasteners 

FA/176  MIL-STD-1312-5 

Magnetic  permeability 

FA/2 1 4       ASTM  A342  Test  Method  3 

Measurement  of  fastener  coating  thickness  -  dimensional 

change  method 

FA/495       MIL-STD-13 12- 12 

Measurement  of  fastener  coating  thickness  -  eddy-current 
method 

FA/152       MIL-STD-13 12-1 2 
Microhardness  of  fasteners 

FA/189  ASTME384 

Recess  strength  test  in  both  the  installation  and  removal 
directions 

FA/476       MIL-STD-13 12-25 
Rockwell  hardness  of  fasteners 
FA/201       MIL-STD-13 12-6 
Rockwell  superficial  hardness  of  fasteners 
FA/209       MIL-STD-13 12-6 

Tension  testing  of  machined  specimens  from  externally 
threaded  fasteners 

FA/475       ASTM  E8 

Wedge  tensile  strength  of full-size  threaded  fasteners 

FA/290      ASTM  F606  Sec.  3.5 
Metallography 

Decarburization  and  case  depth  measurement  in 
fasteners 

FA/483       ASTM  A574  Sec.  12 
Determination  of  grain  size  of fasteners 

FA/331       ASTM  El  12 

Macroscopic  examination  of  fasteners  by  etching 

FA/5 1 1       ASTM  E340 

Microscopic  examination  of  fasteners  by  etching 

FA/341       ASTM  El 077 

Surface  discontinuities  of  externally  threaded  fasteners 

FA/357      ASTM  F788/788M 


NVLAP  1999  DIRECTORY  -  Page  D182 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  200328-0 
Prospect  Testing  Labs,  Inc. 

1245  Forest  Avenue 
Des  Plaines,  IL  60018 
Contact:  Mr.  Seung  W.  Lyu 
Phone:  847-827-4766 
Fax:  847-299-6222 


Fasteners  &  Metals 

Accreditation  Valid  Through:  March  3 1 ,  1999 
NVLAP 

Code  Designation 
Chemical  Analysis 

Optical  emission  spectro chemical  analysis 
FA/457  ASTME415 
FA/459  ASTME1086 
FA/460  ASTME1251 

Mechanical  and  Physical  Testing  and  Inspection 

Axial  tensile  strength  of  full-size  threaded  fasteners 
FA/266      ASTMF606  Sec.  3.4.1-3.4.3 
FA/273       SAE  J429 
FA/530      ASTM  E8 
FA/799      NASM  1312-8 

Hydrogen  embrittlement  (stress  durability)  of  externally 
threaded  fasteners 

FA/875       NASM  1312-5 
FA/924      ASTM  F606 
FA/967  GM6010M 

Hydrogen  embrittlement  (stress  durability)  of  internally 
threaded  fasteners 

FA/968  GM6010M 

Intergranular  corrosion  susceptibility  in  austentic 

stainless  steel  fasteners  -  nitric  aci 

FA/173       ASTM  A262  Sec.  15-21,  Practice  C 

Intergranular  corrosion  susceptibility  of  austentic 

stainles  steel  fasteners  -  oxalic  acid 

FA/1 74      ASTM  A262  Sec.  3-7,  Practice  A 

Measurement  of  fastener  coating  thickness  - 

microscopical  method 

FA/160  ASTMB487 

FA/873      NASM  1312-12 

Measurement  of  fastener  coating  thickness  -  weight  of 
coating 

FA/164      ASTM  A90 
Microhardness  of  fasteners 
FA/189  ASTME384 

Proof  load  of  full-size  externally  threaded  fasteners 
FA/226      ASTM  F606  Sec.  3.2.1-3.2.3 
FA/229      SAE  J429 

Proof  load  of  internally  threaded  fasteners  (nuts) 
FA/236      ASTM  F606  Sec.  4.2 
FA/241       SAE  J995  Sec.  5.1 
Rockwell  hardness  of  fasteners 
FA/197      ASTM  El  8 


Rockwell  superficial  hardness  of  fasteners 

FA/205       ASTM  El 8 

Torque-tension  of full-size  threaded  fasteners 
FA/882      NASM  1312-15 

Torsional  strength  test  of  thread  rolling  and  self-drilling 

tappings  screws 

FA/252      ASTM  F738M 

FA/751  SAEJ933 

FA/966      ASTM  F880M 

Wedge  tensile  strength  of full-size  threaded  fasteners 

FA/290      ASTM  F606  Sec.  3.5 
FA/468       SAE  J429 

Metallography 

Decarburization  and  case  depth  measurement  in 
fasteners 

FA/323       ASTM  El 077 

FA/328  SAEJ121 

Determination  of  grain  size  of fasteners 

FA/331       ASTM  El  12 

Macroscopic  examination  of  fasteners  by  etching 

FA/551  ASTME3 

Microscopic  examination  of  fasteners  by  etching 

FA/552      ASTM  E3 

Surface  discontinuities  of  externally  threaded  fasteners 
FA/361  SAEJ123 
FA/362       SAE  Jl 061 

Surface  discontinuities  of  internally  threaded  fasteners 

FA/365       SAE  J 122 

NVLAP  LAB  CODE  200329-0 
Fabristeel  Products  Inc. 

22100  Trolley  Industrial  Drive 

Taylor,  MI  48180 

Contact:  Ms.  Michelle  Stawowy 

Phone:  313-299-1178 

Fax:  313-299-1190 


Fasteners  &  Metals 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 

Dimensional  Inspection 

Dimensions  of  general  purpose  fasteners  and 

high-volume  machine  assembly  fasteners 

FA/403  ANSI/ASMEB18.18.1M 

FA/404      ANSI/ASME  B 1 8. 1 8.2M 

External  thread  parameters  -  SAE  fastener  with  MJ 

metric  screw  threads 

FA/662       ISO  1502 

External  thread  parameters  -  system  21 

FA/379      ANSI/ASME  BUM 

External  thread  parameters  -  system  22 

FA/381       ANSI/ASME  B1.3M 

Internal  thread  parameters  -  ISO 

FA/402      ISO  1502 


NVLAP  1999  DIRECTORY  -  Page  D183 


(See  'How  To  Use  This  Directory*  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Internal  thread  parameters  -  system  21 

FA/39 1       ANSI/ASME  B1.3M 

Internal  thread  parameters  -  system  22 

FA/393       ANSI/ASME  B1.3M 

Mechanical  and  Physical  Testing  and  Inspection 

Microhardness  of  fasteners 

FA/189  ASTME384 

Rockwell  hardness  of  fasteners 

FA/196       ASTM  A370  Sec.  18 

FA/197       ASTM  El 8 

FA/200      ISO  6508 

FA/202  SAEJ417 

Rockwell  superficial  hardness  of  fasteners 

FA/205       ASTM  El 8 

FA/206      ASTM  A370  Sec.  1 8 

Metallography 

Decarburization  and  case  depth  measurement  in 
fasteners 

FA/323  ASTM  El 077 
FA/324  ISO  898-1 
FA/325  ISO  898-5 
FA/328  SAEJ121 
FA/329  SAEJ419 
FA/758  SAEJ121M 

Macroscopic  examination  of  fasteners  by  etching 
FA/334       ISO  6157-1 
FA/335      ISO  6157-3 
FA/336       SAE  J 123 
FA/337       SAE  J 1061 

Microscopic  examination  of  fasteners  by  etching 

FA/341       ASTM  El 077 

FA/342       ISO  898-1 

FA/343       ISO  898-5 

FA/344  SAEJ121 

FA/471  SAEJ419 

FA/759  SAEJ121M 

Surface  discontinuities  of  externally  threaded  fasteners 

FA/357       ASTM  F788/788M 
FA/358      ASTM  F788M 
FA/359       ISO  6157-1 
FA/360      ISO  6157-3 
FA/361       SAE  J 123 
FA/362       SAE  J 1061 

Surface  discontinuities  of  internally  threaded  fasteners 
FA/363       ASTM  F8 12 
FA/364      ASTM  F812M 
FA/365  SAEJ122 


NVLAP  LAB  CODE  200331-0 
HomeTek  Technology  Inc. 

No.  85-5  Shir  Men  Rd.,  Tu  Cheng  City 

Taipei  Shien  236 

TAIWAN 

Contact:  Mr.  Grant  Huang 

Phone:  886-2-22608375 

Fax:  886-2-22748013 

E-Mail:  hometek@msl5.hinet.net 

FCC  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

1 2/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200333-0 
EMSL  Analytical,  Inc. 

1 75  Clearbrook  Road 

Cross  West  Chester  Executive  Plaza 

Elmsford,NY  10523 

Contact:  Mr.  Robert  Georgens 

Phone:  914-592-4688 

Fax:  914-592-6798 

URL:  http://www.emsl.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  1999  DIRECTORY  -  Page  D184 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  200335-0 
Hygeia  Laboratories,  Inc. 

9955  NW  116  Way,  Suite  1 
Miami,  FL  33178 
Contact:  Mr.  Julio  Lopez 
Phone:  305-882-8200 
Fax:  305-882-1200 

E-Mail:  LOPEZ31@ATC-ENVIRO.COM 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  200336-0 
Pratt  &  Whitney  Materials  Control  Laboratory 

400  Main  Street,  Mail  Stop  184-25 
East  Hartford,  CT  06108 
Contact:  Mr.  Donald  J.  Baron 
Phone:  860-565-2857 
Fax:  860-565-2897 
E-Mail:  barondj@pweh.com 

Fasteners  &  Metals 

Accreditation  Valid  Through:  June  30,  1999 
NVLAP 

Code  Designation 
Chemical  Analysis 

Combustion  analysis  for  carbon,  sulfur,  oxygen, 
nitrogen,  and  hydrogen 

FB/1024  P&WM-165 

FB/1025  P&WM-166 

FB/1026  P&WM-175 

Energy  dispersive  X-ray  analysis 

FB/1030  P&WN-51 

Optical  emission  spectrochemical  analysis 

FB/1027  P&WM-186 

FB/1028  P&WN-ll 

X-ray  fluorescence  (XRF)  spectrochemical  analysis 
FB/1029  P&WN-60 

Mechanical  and  Physical  Testing  and  Inspection 

Axial  tensile  strength  of full-size  threaded  fasteners 

FB/1018  P&WK-32 

Brinell  hardness  of  fasteners 

FB/1009  P&WE-OSuppC 

Charpy  impact  (v-notch)  testing 

FB/1014  P&WK-162 

Fatigue  of full-size  threaded  fasteners 

FB/1008  P&WK-317 


Flareability  test  of  clinch  and  shank  nuts 

FB/1006  P&WK-309 

Microhardness  of  fasteners 

FB/1010  P&WE-OSuppC 

Proof  load  of full-size  externally  threaded  fasteners 

FB/1015  P&WK-32 

Proof  load  of  internally  threaded  fasteners  (nuts) 

FB/1016  P&WK-32 

Rockwell  hardness  of  fasteners 

FB/1011  P&WE-OSuppC 

Rockwell  superficial  hardness  of  fasteners 

FB/1012  P&WE-OSuppC 

Salt  spray  testing  of  fasteners 

FB/1007  P&WP-23 

Stress  rupture  of  fasteners 

FB/1017  P&WE-1107 

Vickers  hardness  -  test  forces  from  9.807  to  1176  N  (1  to 
120  kgf) 

FB/1013  P&WE-OSuppC 
Metallography 

Decarburization  and  case  depth  measurement  in 
fasteners 

FB/1019  P&WE-23 

Determination  of  grain  size  of fasteners 

FA/331  ASTME112 

Macroscopic  examination  of  fasteners  by  etching 

FB/1020  P&WK-76 

Microscopic  examination  of  fasteners  by  etching 

FB/1021  P&WE-23 

Surface  discontinuities  of  externally  threaded  fasteners 

FB/1022  P&WE-23 
FB/1023  P&WE-242 

NVLAP  LAB  CODE  200337-0 
IBM  Charlote  EMC  Facility 

8501  IBM  Drive,  MG  22-202 

Charlotte,  NC  28262-8563 

Contact:  Mr.  Donald  B.  Steigerwalt 

Phone:  704-594-1533 

Fax:  704-594-7376 

E-Mail:  dsteigerwalt@vnet.ibm.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 

Devices 

1 2/FO  la      Conducted  Emissions,  Power  Lines,  450  KHz 
to  30  MHz 


NVLAP  1999  DIRECTORY  -  Page  D185 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200339-0 

Incotec  Laboratory 

1391  Poole  Street 

Mojave,  CA  93501 

Contact:  Mr.  Winston  E.  Wade 

Phone:  805-824-8101 

Fax:  805-824-1558 


Fasteners  &  Metals 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

Mechanical  and  Physical  Testing  and  Inspection 

Adhesion  of  metallic  coatings  on  fasteners 

FA/532      BMS  10-85M  Sec.  8.2 
FA/779      BSS  7225 
FA/996      ASTM  D4541 
FA/997      HS  292 
FA/998       HS  294 
FA/999      NAS  4006 

Adhesion  of  nonmetallic  coatings  on  fasteners 

FA/991       BSS  7225 
FA/992       HS  292 
Coating  endurance 

FA/995       ASTM  D2625 

Copper  sulfate  test  -  test  for  free  iron  on  the  surface  of 

corrosion  resistant  fasteners 

FA/636       MIL-STD-753  Test  102 

Elevated  temperature  testing  capability 

FB/1001      BMS  10-85 

FB/1002     BSS  7225 

Film  hardness 

FA/993       BMS  10-85M 

FA/994      ASTM  D3363 

Humidity  testing  of  fasteners 

FA/169       MIL-STD-753  Test  Method  101 

FA/548       ASTM  D2247 

Measurement  of  fastener  coating  thickness  -  dimensional 

change  method 

FA/495       MIL-STD-13 12-12 

Measurement  of  fastener  coating  thickness  - 

microscopical  method 

FA/163       MIL-STD-13 12-12 

Salt  spray  testing  of  fasteners 

FA/166       ASTM  Bl  17 

FB/1000  ASTMG85 

Water  immersion  method  -  test  for  anodic  surface 
containment  on  corrosion  resistant  fasten 
FA/756      MIL-STD-753  Test  100 


NVLAP  LAB  CODE  200340-0 
Diviersified  T.E.S.T.  Technologies,  Inc. 

556  Route  222,  P.O.  Box  8 

Groton,NY  13073 

Contact:  Mr.  Thomas  P.  Sims 

Phone:  607-898-4218 

Fax:  607-898-4830 

E-Mail:  tom@diversifiedtechnol.com 

URL:  http://diversifiedtechnol.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  December  31,  1999 

NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

1 2/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200341-0 
United  Steel  and  Fasteners  Inc. 

1500  Industrial  Drive 
Itasca,  IL  60143 
Contact:  Mr.  Antonio  Zaccari 
Phone:  630-250-0900 
Fax:  630-250-0220 
E-Mail:  us_f@msn.com 

Fasteners  &  Metals 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 
Dimensional  Inspection 

Dimensions  of  fasteners  -  bearing  surface  squareness 

FA/745       ANSI  B  18.2.1 

Dimensions  of  fasteners  -  straightness 

FA/423       ANSI/ASMEB  18.2.1 

Dimensions  of  general  purpose  fasteners  and 

high-volume  machine  assembly  fasteners 

FA/494      ANSI  B 18. 2.1 

Mechanical  and  Physical  Testing  and  Inspection 

Axial  tensile  strength  of full-size  threaded  fasteners 

FA/266      ASTM  F606  Sec.  3.4. 1  -3.4.3 
FA/273       SAE  J429 


NVLAP  1999  DIRECTORY  -  Page  D186 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Proof  load  of full-size  externally  threaded  fasteners 
FA/226      ASTM  F606  Sec.  3.2.1-3.2.3 
FA/229      SAE  J429 
Rockwell  hardness  of  fasteners 
FA/202  SAEJ417 
FA/482      ASTM  F606 

Tension  testing  of  machined  specimens  from  externally 
threaded  fasten  ers 

FA/279      ASTM  F606  Sec.  3.6 
FA/283       SAE  J429 

NVLAP  LAB  CODE  200344-0 
EMSL  Analytical  Mobile  Laboratory 

4444  West  Haddon  Avenue 
Chicago,  EL  60651 
Contact:  Ms.  Lee  Harbour 
Phone:  773-235-1409 
Fax:  773-235-1434 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  September  30,  1999 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  September  30,  1999 


NVLAP  LAB  CODE  200345-0 
Ricoh  Company  LTD.  Ohmori  Acoustics  Test  Site 
3-6,  1  Chome,  Nakamagome,  Ohta-ku 
Tokyo  143-8555 
JAPAN 

Contact:  Mr.  Yuji  Noritake 

Phone:  03-3777-8183 

Fax:  03-3777-0811 

E-Mail:  yuji.noritake(ants.ricoh.co.jp 

Acoustical  Testing  Services 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

08/P24       ANSI  S 1 2. 1 0  (ISO  7779) 

NVLAP  LAB  CODE  200346-0 
SCDLAB  California,  Inc. 

24416  South  Main  Street,  Suite  308 

Carson,  CA  90745 

Contact:  Mr.  Roobik  Yaghoubi 

Phone:  310-834-4868 

Fax:310-834-4772 


NVLAP  LAB  CODE  200347-0 

Quietek  Corporation 

12F-4,  No.  333,  Sec.  1,  Guan-Fu  Road 

Hsin-Chu  City 

TAIWAN 

Contact:  Mr.  Gene  Chang 
Phone:  886-3-5928858 
Fax:  886-3-5928859 
E-Mail:  genecha@ms6.hinet.net 

FCC  Test  Methods 

Accreditation  Valid  Through:  September  30,  1999 

NVLAP  „ 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12.T51  AS/NZS3548 

Federal  Communications  Commission  (FCC)  Methods 
12/F01       FCC  Method  -  47  CFR  Part  15  -  Digital 
Devices 

12/F01a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
12/F01b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 

NVLAP  LAB  CODE  200349-0 
Crisp  Analytical  Laboratory 

2081  Hutton  Drive,  Suite  309 
Carrollton,  TX  75006 
Contact:  Mr.  David  Bertolacci 
Phone:  972-488-1414 
Fax:  972-488-8006 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  September  30,  1999 


Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  September  30,  1999 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  September  30,  1999 

Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  December  31,  1999 


NVLAP  1999  DIRECTORY  -  Page  D187 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  200350-0 
White  Environmental  Consultants,  Inc. 

1 130  N.  NimitzHwy.  #3220 
Honolulu,  HI  96817 
Contact:  Mr.  Jim  Willard 
Phone:  808-536-8819 
Fax:  808-536-0191 
E-Mail:  weclabs@gte.net 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  September  30,  1999 


NVLAP  LAB  CODE  200353-0 
Alloy  &  Stainless  Testing 

1493  London  Bridge  Road 
Virginia  Beach,  VA  23456 
Contact:  Mr.  Randy  Earles 
Phone:  757-427-0111  x  1 1 1 
Fax:  757-427-2658 
E-Mail:  RAEARLES@AOL.COM 

Fasteners  &  Metals 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 
Dimensional  Inspection 

Dimensions  of  special  purpose  fasteners  and  fasteners  for 

highly  specialized  engineered  ap 

FA/963       ANSI  B 18. 2.1 

External  thread  parameters  -  system  21 

FA/379       ANSI/ASME  B1.3M 

External  thread  parameters  -  system  22 

FA/38 1       ANSI/ASME  B 1 .3M 

Internal  thread  parameters  -  system  21 

FA/39 1       ANSI/ASME  B 1 ,3M   

NVLAP  LAB  CODE  200356-0 
M&M  Manufacturing  Corportation 
5611  Kimball  Court 
Chino,  CA  91710 
Contact:  Ms.  Wendy  McBride 
Phone:  909-597-7211 
Fax:  909-597-0881 


Fasteners  &  Metals 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 
Dimensional  Inspection 

Dimensions  of  fasteners  -  straightness 

FA/423       ANSI/ASME  B 1 8.2. 1 


Dimensions  of  general  purpose  fasteners  and 
high-volume  machine  assembly  fasteners 

FA/403       ANSI/ASME  B18. 18. 1M 

FA/404      ANSI/ASME  B 1 8. 1 8.2M 

Dimensions  of  special  purpose  fasteners  and  fasteners  for 

highly  specialized  engineered  ap 

FA/405       ANSI/ASME  B  18.1 8. 3M 

FA/406       ANSI/ASME  Bl  8. 18.4M 

External  thread  parameters  -  system  22 

FA/382  FED-STD-H28/20 

Surface  texture 

FA/439      ANSI/ASME  B46.1 

Mechanical  and  Physical  Testing  and  Inspection 

Axial  tensile  strength  of full-size  threaded  fasteners 
FA/271  MIL-STD-1312-8 
Double  shear  of  externally  threaded  fasteners 
FA/257  MIL-STD-1312-13 

Hydrogen  embrittlement  (stress  durability)  of  externally 

threaded  fasteners 

FA/176  MIL-STD-1312-5 

Measurement  of  fastener  coating  thickness  -  dimensional 

change  method 

FA/495  MIL-STD-1312-12 

Measurement  of  fastener  coating  thickness  - 

microscopical  method 

FA/ 163  MIL-STD-1312-12 

Microhardness  of  fasteners 

FA/193  MIL-STD-1312-6 

Recess  strength  test  in  both  the  installation  and  removal 
directions 

FA/476  MIL-STD-1312-25 

Rockwell  hardness  of  fasteners 

FA/201  MIL-STD-1312-6 

Rockwell  superficial  hardness  of  fasteners 

FA/209  MIL-STD-1312-6 

Single  shear  of  externally  threaded  fasteners 

FA/256  MIL-STD-1312-20 

Vickers  hardness  -  test  forces  from  9.807  to  11 76  N  (1  to 
120  kgf) 

FA/671  MIL-STD-1312-6 
Metallography 

Decarburization  and  case  depth  measurement  in 
fasteners 

FA/323  ASTME1077 
Determination  of  grain  size  of fasteners 

FA/331  ASTME112 

Macroscopic  examination  of  fasteners  by  etching 

FA/511  ASTME340 

FA/651       ASTM  F788/788M 

Microscopic  examination  of  fasteners  by  etching 

FA/341       ASTM  El 077 
FA/345       ASTM  F788/788M 
FA/351       ASTM  El  12 
FA/512  ASTME407 
FA/552       ASTM  E3 
FA/679       ASTM  A574 


NVLAP  1999  DIRECTORY  -  Page  D188 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Surface  discontinuities  of  externally  threaded  fasteners 
FA/357      ASTM  F788/788M 
Nondestructive  Inspection 

Liquid  penetrant  inspection  of fasteners 

YKIS21      ASTM  El 41 7 

Magnetic  particle  inspection  of  fasteners 

FA/485       ASTM  E1444  

NVLAP  LAB  CODE  200357-0 
AGRA  Earth  and  Environmental,  Inc.  -  Env. 
Chemistry  Laboratory 
7477  SW  Tech  Center  Dr. 
Portland,  OR  97223-8025 
Contact:  Mr.  Sean  F.  Gormley 
Phone:  503-639-3400 
Fax:  503-620-7892 
E-Mail:  sgormley@agrans.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  December  31,  1999 


NVLAP  LAB  CODE  200358-0 
Patriot  Environmental  Laboratory  Services 

12752  Valley  View  St.,  Suite  C 

Garden  Grove,  CA  92845 

Contact:  Mr.  James  Thornbrugh,  II 

Phone:  714-899-8900 

Fax:  714-899-7098 

E-Mail:  JThornbrugh@earthlink.net 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  September  30,  1999 


NVLAP  LAB  CODE  200361-0 
Architectural  Testing  Inc. 

130  Deny  Ct. 

York,  PA  17402 

Contact:  Mr.  Eric  J.  Miller 

Phone:  717-764-7700 

Fax:  717-764-4129 

E-Mail:  ati.york@worldnet.att.net 

Acoustical  Testing  Services 

Accreditation  Valid  Through:  September  30,  1999 
NVLAP 

Code  Designation 

08/P03  ASTM  C423  (ISO  354) 

08/P06  ASTM  E90  (ISO  140,  Part  3) 

08/P30  ASTM  El 408 

08/P31  ASTME336 

08/P37  ASTM  E966 

08/P43  ASTM  El 425 


NVLAP  LAB  CODE  200362-0 
TEAC  Corporation  EMC  Center 

857  Koyata,  Iruma-shi 
Saitama-ken  358-851 
Iruma-shi  81-358-8510 
JAPAN 

Contact:  Mr.  Daihachiro  Takasu 
Phone:  81-42-462-7159 
Fax:  81-42-963-7153 
E-Mail:  d-takasu@it.teac.co.jp 

FCC  Test  Methods 

Accreditation  Valid  Through:  December  31,1 999 
NVLAP 

Code  Designation 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  la      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
12/F01b      Radiated  Emissions 

NVLAP  LAB  CODE  200363-0 
Sun  Microsystems,  Inc.  EMC  Testing 

901  San  Antonio  Road 

MS  UMPK25-101 

Palo  Alto,  CA  94303-4900 

Contact:  Mr.  Hugh  Hagel 

Phone:  650-786-3215 

Fax:  650-786-4316 

E-Mail:  Hugh.Hagel@sun.com 

FCC  Test  Methods 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO  1       FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  la      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  lb      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 


NVLAP  1999  DIRECTORY  -  Page  D189 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  D.  LISTING  OF  TESTING  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  200368-0 
Sony  Minokamo  EMC  Site 

9-15-22,  Hongo-cho  Minokamo  City 

Gifu-Pref.  505-8510 

JAPAN 

Contact:  Mr.  Kazuo  Takarajima 

Phone:  81-574-25-8161 

Fax:  81-574-28-8087 

E-Mail:  takarajm@mkm.sony.co.jp 

FCC  Test  Methods 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO 1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/F0 la      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
12/F01b      Radiated  Emissions 

NVLAP  LAB  CODE  200373-0 
Fujitsu  General  EMC  Laboratory 

1116,  Suenaga,  Takatsu-ku 
Kawasaki  213-8502 
JAPAN 

Contact:  Mr.  Hiroyuki  Shimanoe 

Phone:  81-44-861-7897 

Fax:  81-44-861-9890 

E-Mail:  shimanoe@fujitsugeneral.co.jp 

FCC  Test  Methods 

Accreditation  Valid  Through:  December  31,  1999 
NVLAP 

Code  Designation 

Australian  Standards  referred  to  by  clauses  in  AUSTEL 
Technical  Standards 

12/T51       AS/NZS  3548 

Federal  Communications  Commission  (FCC)  Methods 
1 2/FO  1        FCC  Method  -  47  CFR  Part  1 5  -  Digital 
Devices 

1 2/FO  1  a      Conducted  Emissions,  Power  Lines,  450  KHz 

to  30  MHz 
1 2/FO  1  b      Radiated  Emissions 

International  Special  Committee  on  Radio  Interference 
(CISPR)  Methods 

12/CIS22    IEC/CISPR  22:1993:  Limits  and  methods  of 
measurement  of  radio  disturbance 
characteristics  of  information  technology 
equipment 


NVLAP  LAB  CODE  200374-0 
EnviroHealth  Technologies,  Inc. 

3830  Washington  Boulevard,  Suite  123 
St.  Louis,  MO  63108 
Contact:  Mr.  William  J.  Lowry 
Phone:  314-531-9868 
Fax:  314-531-9196 


Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  June  30,  1999 


NVLAP  LAB  CODE  200375-0 
EMSL  Analytical,  Inc. 

1 1931  Industriplex,  Suite  100 
Baton  Rouge,  LA  70809 
Contact:  Mr.  Arthur  Hernandez,  Jr. 
Phone:  225-755-1920 
Fax:  225-755-1989 

URL:  http://www.emsl.com 

Bulk  Asbestos  Analysis  (PLM) 

Accreditation  Valid  Through:  December  31,  1999 


Airborne  Asbestos  Analysis  (TEM) 

Accreditation  Valid  Through:  December  31,  1999 


NVLAP  1999  DIRECTORY  -  Page  D190 


(See  'How  To  Use  This  Directory'  on  page  7.) 


( 


< 


I 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE 


NVLAP  LAB  CODE  105000-0 

OAK  RIDGE  METROLOGY  CENTER 

P.O.  Box  2009 
Oak  Ridge,  TN  37831-7670 
Contact:  Mr.  W.  T.  (Bill)  McKeethan 
Phone:  423-574-2707    Fax:  423-574-2802 
E-Mail:  wmt@ornl.gov 
URL:  http : //www. ornl . gov/orcmt/mfgqual 

Accreditation  Valid  Through:  March  31,  1999 


DIMENSIONAL 

NVLAP  Code:  20/D05 
Length 

Range 

0  -  1.35  m 

0  -  1.2  m 


Best  Uncertainty  (±)note  1 

(0.3  +  0.4L)  micrometers;  L  is 
length  in  meters 

(0.3  +  0.4L)  micrometers;  L  is 
length  in  meters 


Remarks 

Step  and  End  Gages  using  M-60 
Coordinate  Measuring  Machine 

Step  and  End  Gages  using  M-48 
Coordinate  Measuring  Machine 


1.     Represents  an  expanded  uncertainty  using  a  coverage  factor,  k=2 


NVLAP  1999  DKECTORY  -  Page  E3 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  105001-0 

RICE  LAKE  WEIGHING  SYSTEMS 

230  West  Coleman  Street 
P.O.  Box  272 
Rice  Lake,  WI  54868 
Contact:  Mr.  Richard  Calkins 
Phone:  715-234-9171  x243    Fax:  715-234-6967 
E-Mail:  riccal@rlws.com 
URL:  http://www.rlws.com 

Accreditation  Valid  Through:  March  31,  1999 

MECHANICAL 

NVLAP  Code:  20/M08 
Mass 


Range 

Best  Uncertainty  (±)n0,e  1 

Remarks 

30  kg 

6.5  mg 

Class  I  Facility 

20  kg 

6.4  mg 

Class  I  Facility 

10  kg 

1.5  mg 

Class  I  Facility 

5  kg 

0.78  mg 

Class  I  Facility 

3  kg 

0.52  mg 

Class  I  Facility 

2  kg 

0.36  mg 

Class  I  Facility 

1  kg 

0.050  mg 

Class  I  Facility 

500  g 

0.035  mg 

Class  I  Facility 

300  g 

0.028  mg 

Class  I  Facility 

200  g 

0.027  mg 

Class  I  Facility 

100  g 

0.030  mg 

Class  I  Facility 

50  g 

0.0165  mg 

Class  I  Facility 

30  g 

0.0111  mg 

Class  I  Facility 

20  g 

0.0089  mg 

Class  I  Facility 

10  g 

0.0084  mg 

Class  I  Facility 

5g 

0.0052  mg 

Class  I  Facility 

3g 

0.0039  mg 

Class  I  Facility 

2g 

0.0035  mg 

Class  I  Facility 

lg 

0.0037  mg 

Class  I  Facility 

500  mg 

0.00276  mg 

Class  I  Facility 

300  mg 

0.00222  mg 

Class  I  Facility 

200  mg 

0.00212  mg 

Class  I  Facility 

100  mg 

0.00242  mg 

Class  I  Facility 

50  mg 

0.00206  mg 

Class  I  Facility 

NVLAP  1999  DD2ECTORY  -  Page  E4 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


J7*f  »n  ft  jt 

Kiistge 

tsest  uncertainty  (±) 

Remarks 

■2A  mn 

ju  mg 

n  nm  79  mn 
u.uui  /z  mg 

Class  I  Facility 

OA  mo 

ZU  mg 

n  C\C\  1  70.  mn 

u.uui  iv  mg 

Class  I  Facility 

1  f)  ma 
IV  mg 

n  nm  q/i  ma 
u.uui mg 

1^ loco  T  P  o r* 1 1 1 i~\ i 
V^ldbb  1  rdLUlly 

S  ma 

j  mg 

n  nm  9^  ma 

u .     i  zo  mg 

f1  loCO    T    HQ  C  1 1  1 f"\  / 

V^laao  1  FdCllliy 

J  lilg 

ft  ftftftQzl  ma 

V-'la.oo  1  FdCllILy 

2  mg 

ft  00086  ma 

U.UUUoO  Illg 

■  ^  1  q  co  T  Po. r* 1 1 1  / 
v^ldoa  1  FdCllliy 

1  mg 

n  nnnoA  ma 
u.uuuy^t  mg 

Class  I  Facility 

jU  Kg 

3U4  mg 

Class  II  Facility 

JU  Kg 

7  mg 

■     loco    II  I— HO  f>  1  1  1 J 

v—idss  11  rdcuny 

9ft  ta 
ZU  Kg 

6  mg 

t1 1  Q  CO    IT    pQ  r*1 1 1 1~\7 

v_.id.Do  ii  Fdcuiiy 

1U  K.g 

1.5  mg 

IMqcc  IT  Pq/"*i  lit"\/ 
v_-idoo  ii  Fddiiiy 

J  Kg 

ft  78  ma 

u .  /  o  mg 

V_-ld!>o  11  FdCllliy 

J  Kg 

0,  ^,9  ma 

u.jz  mg 

I^IQGO    TT  pQ.r*lllf~\/ 

v_-idoa  ii  rdcuny 

9  Wr 
Z  Kg 

u.jo  mg 

Class  II  Facility 

1  Vrr 

1  Kg 

A  AC  -rvirr 

u.Uj  mg 

Class  II  Facility 

jUU  g 

A.  A/1  ma 

u.u<+  mg 

Class  II  Facility 

inn  n 
JUU  g 

A  ft-}  ma 

u.uj  mg 

1  o  o  c   T  T   Po  /"*  1 1 1 1~\  1 

\^ida^  ii  Fdciiny 

zuu  g 

ft  01  ma 
u.Uj  mg 

1  a q o  I T  Po. r* 1 1 1 i~\ i 
v-,iabo  ii  rdLiniy 

1  Dfl  rr 

1UU  g 

A  fllfl  ma 

u.uju  mg 

V_ldoo  11  FdClllLy 

->U  g 

A  A1  7  ma 

u.ui  /  mg 

f1  looc  T  T  Th  o  r*  1 1 1 1"\  i 
V_ldbS»  11  FdCllliy 

31)  g 

H  HI  1  ma 

u.uii  mg 

f   loco   T  T  1— i  o  r'lli  ~t~\  j 

v_laSS  11  rdl,llliy 

9f\  rr 

ZU  g 

u.uuy  mg 

1^  1  O  nn     T  T     La  f\  *  1  4  4-\  j 

v^iass  11  raLiiiiy 

1U  g 

C\  HHQ  ma 

U.UUo  mg 

I      lrinn     T  T     T_?rt  Alii  1~\  J 

Vwiass  ii  racniiy 

C.  rr 

n  nn^9  ma 
u.uujz  mg 

§  '  loco   T  T    I_j'o  r*  1 1 1 1"\  t 

v_,iass  ii  Fdciiuy 

1  rr 
J  g 

A  AftlQ  ma 

u.uujz  mg 

loco  T T   m q r* 1 1 1 f~i j 
l_ldo!>  11  FdCllliy 

0  rr 

A  ma 
U.UU.JJ  mg 

1  q  co  T T  Po. C 1 1 1  t"V 

v_-iaio  ii  FdL-iniy 

1  /"» 

1  g 

A  AA"37  ma 

U.UUJ  /  mg 

■  ^  loco  T  T  Pq  r*  1 1 1 1~\  j 
V_.ldL>a  11  FdLllliy 

jUU  mg 

A  AAQ  mrr 

u.uuj  mg 

1^  loco    1  T    Lh'o  f>  1 1 1  f~r  j 

v_iass  ii  racniiy 

300  mg 

A    A  AO  mrr 

U.UUz  mg 

Class  II  Facility 

200  mg 

A  AAO  mrt 

u.uuz  mg 

Class  II  Facility 

100  mg 

0.002  mg 

Class  II  Facility 

50  mg 

0.002  mg 

Class  II  Facility 

30  mg 

0.002  mg 

Class  II  Facility 

20  mg 

0.002  mg 

Class  II  Facility 

NVLAP  1999  DIRECTORY  -  Page  E5 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Range 

Best  Uncertainty  (±)no'e  1 

Remarks 

10  mg 

0.002  mg 

Class  II  Facility 

5  mg 

0.001  mg 

Class  II  Facility 

3  mg 

0.001  mg 

Class  II  Facility 

2  mg 

0.001  mg 

Class  II  Facility 

1  mg 

0.001  mg 

Class  II  Facility 

1000  kg 

19  g 

Class  III  Facility 

500  kg 

11  g 

Class  III  Facility 

200  kg 

1.4  g 

Class  III  Facility 

100  kg 

1.4  g 

Class  III  Facility 

50  kg 

770  mg 

Class  III  Facility 

30  kg 

12  mg 

Class  III  Facility 

20  kg 

12  mg 

Class  III  Facility 

10  kg 

1.5  mg 

Class  III  Facility 

5  kg 

0.84  mg 

Class  III  Facility 

3  kg 

0.59  mg 

Class  III  Facility 

2  kg 

0.47  mg 

Class  III  Facility 

1  kg 

0.062  mg 

Class  III  Facility 

500  g 

0.051  mg 

Class  III  Facility 

300  g 

0.046  mg 

Class  III  Facility 

200  g 

0.045  mg 

Class  III  Facility 

100  g 

0.031  mg 

Class  III  Facility 

50  g 

0.017  mg 

Class  III  Facility 

30  g 

0.012  mg 

Class  III  Facility 

20  g 

0.012  mg 

Class  III  Facility 

10  g 

0.011  mg 

Class  III  Facility 

5g 

0.005  mg 

Class  III  Facility 

3g 

0.004  mg 

Class  III  Facility 

2g 

0.004  mg 

Class  III  Facility 

lg 

0.004  mg 

Class  III  Facility 

500  mg 

0.003  mg 

Class  III  Facility 

300  mg 

0.002  mg 

Class  III  Facility 

200  mg 

0.002  mg 

Class  III  Facility 

100  mg 

0.003  mg 

Class  III  Facility 

50  mg 

0.002  mg 

Class  III  Facility 

NVLAP  1999  DHtECTORY  -  Page  E6 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  Code:  20/M08 
Mass  Avoirdupois 


Range 

Best  Uncertainty  (±)notel 

Remarks 

30  mg 

0.002  mg 

Class  III  Facility 

20  mg 

0.002  mg 

Class  III  Facility 

10  mg 

0.002  mg 

Class  III  Facility 

5  mg 

0.001  mg 

Class  III  Facility 

3  mg 

0.001  mg 

Class  III  Facility 

2  ms? 

0  001  ms 

Class  ITT  Facilirv 

1  m  cr 

o cc  T T T  Pa c i  1  i t~v 

V^idoo  III  I  a.dlll\ 

Range 

Best  Uncertainty  (±)note  1 

Remarks 

2500  lb 

52  g 

Class  III  Facility 

2000  lb 

17  g 

Class  III  Facility 

1000  lb 

6.5  g 

Class  III  Facility 

500  lb 

1.4  g 

Class  III  Facility 

250  lb 

1.4  g 

Class  III  Facility 

200  lb 

1.4  g 

Class  III  Facility 

100  lb 

49  mg 

Class  III  Facility 

50  lb 

14  mg 

Class  III  Facility 

30  lb 

12  mg 

Class  III  Facility 

25  lb 

23  mg 

Class  III  Facility 

20  lb 

2.2  mg 

Class  III  Facility 

10  lb 

1.1  mg 

Class  III  Facility 

5  lb 

0.63  mg 

Class  III  Facility 

4  lb 

0.97  mg 

Class  III  Facility 

3  lb 

0.47  mg 

Class  III  Facility 

2  lb 

0.10  mg 

Class  III  Facility 

1  lb 

0.06  mg 

Class  III  Facility 

0.5  lb 

0.05  mg 

Class  III  Facility 

0.3  lb 

0.045  mg 

Class  III  Facility 

0.2  lb 

0.025  mg 

Class  III  Facility 

0.1  lb 

0.028  mg 

Class  III  Facility 

0.05  lb 

0.016  mg 

Class  III  Facility 

0.03  lb 

0.012  mg 

Class  III  Facility 

0.02  lb 

0.010  mg 

Class  III  Facility 

NVLAP  1999  DmECTORY  -  Page  E7 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Range 

Best  Uncertainty  (±)no'e  1 

Remarks 

0.01  lb 

0.007  mg 

Class  III  Facility 

0.005  lb 

0.004  mg 

Class  III  Facility 

0.003  lb 

0.003  mg 

Class  III  Facility 

0.002  lb 

0.003  mg 

Class  III  Facility 

0.001  lb 

0.003  mg 

Class  III  Facility 

4  oz 

0.045  mg 

Class  III  Facility 

2  oz 

0.025  mg 

Class  III  Facility 

1  oz 

0.027  mg 

Class  III  Facility 

1/2  oz 

0.016  mg 

Class  III  Facility 

1/4  oz 

0.010  mg 

Class  III  Facility 

1/8  oz 

0.008  mg 

Class  III  Facility 

1/16  oz 

0.008  mg 

Class  III  Facility 

1/32  oz 

0.008  mg 

Class  III  Facility 

1.     Represents  an  expanded  uncertainty  using  a  coverage  factor,  k=2 


NVLAP  1999  DIRECTORY  -  Page  E8 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


SANDIA  NATIONAL  LABORATORIES 

Primary  Electrical  Standard  Dept.  1542 
P.O.  Box  5800,  Mail  Stop  0665 
Albuquerque,  NM  87185-0665 
Contact:  Dr.  Richard  B.  Pettit 
Phone:  505-844-6242    Fax:  505-844-4372 
E-Mail:  rbpetti@sandia.gov 
URL:  http://www.sandia.gov/psl 


Accreditation  Valid  Through:  December  31,  1999 


NVLAP  LAB  CODE  105002-0 


DIMENSIONAL 

NVLAP  Code:  20/D01 
Angular 

Range 

Angle  Blocks 

Optical  Squares 
True  Squares 


Best  Uncertainty  (±)  in  percent0''1 
0.60  arc  second 

0.46  arc  second 
0.28  arc  second 


Remarks 

Standard  Sizes,  1  arc  second 
to  45° 


NVLAP  Code:  20/D03 
Gage  Blocks 

Range 

to  100  mm  (4  in) 

to  100  mm  (4  in) 
<  1  mm  (.04  in) 

1  to  100  mm  (.04  to  4  in) 

125  to  500  mm  (5  to  20  in) 


Best  Uncertainty  (±)  in  percent"010 1,1 
30  nm  +  0.14  L 

34  nm  +  0.33  L 

41  nm 

35  nm  +  0.59  L 
127  nm  +  0.30  L 


Remarks 

Interferometry  with  Historical 
Analysis 

Interferometry,  single  wiring 

Mechanical  Comparison  to 

Masters"016  2X4 

Mechanical  Comparison  to 
Masters"0'6  2X4 

Mechanical  Comparison  to 
Masters"0'6  2X4 


NVLAP  1999  DIRECTORY  -  Page  E9 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


DC/LOW  FREQUENCY 

NVLAP  Code:  20/E01 
Voltage  Converters 


Best  Uncertainty  (±)in  ppm' 
Frequency  in  Hertz 


Range 

10 

100 

1  k 

20  k 

50  k 

100  k 

200  k 

500  k 

1  M 

1  V 

102 

20 

23 

17 

26 

42 

71 

73- 

75 

2  V 

101 

18 

17 

21 

27 

42 

72 

71 

73 

3  V 

102 

16 

18 

17 

27 

42 

71 

73 

75 

4  V 

101 

17 

17 

19 

30 

42 

71 

71 

72 

6  V 

101 

16 

16 

17 

27 

41 

72 

74 

76 

10  V 

101 

16 

18 

18 

27 

41 

72 

73 

74 

12  V 

101 

18 

18 

16 

27 

42 

72 

72 

73 

20  V 

104 

19 

16 

17 

30 

41 

72 

76 

78 

30  V 

102 

17 

16 

16 

27 

42 

71 

76 

77 

40  V 

101 

17 

16 

19 

27 

41 

73 

76 

77 

60  V 

101 

23 

16 

17 

27 

42 

71 

71 

74 

100  V 

101 

19 

16 

17 

28 

43 

73 

75 

75 

120  V 

102 

22 

21 

22 

31 

52 

200  V 

101 

23 

22 

24 

32 

51 

300  V 

103 

29 

25 

25 

34 

56 

400  V 

102 

21 

22 

22 

32 

59 

600  V 

102 

23 

22 

21 

33 

57 

1000  V 

104 

31 

29 

31 

43 

69 

NVLAP  Code:  20/E01 
AC  Current  Shunts 


Range  Frequency  Best  Uncertainty  (±)  in  percent"' 

10  mA  50  kHz  0.010 

25  mA  50  kHz  0.010 

50  mA  50  kHz  0.010 

100  mA  50  kHz  0.014 

250  mA  50  kHz  0.010 

500  mA  50  kHz  0.011 

1A  50  kHz  0.011 

1  A  100  kHz  0.014 

2.5  A  50  kHz  0.011 


NVLAP  1999  DIRECTORY  -  Page  E10 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Range  Frequency  Best  Uncertainty  (±)  in  percent"0"1 

5  A  50  Hz  0.009 

5  A  60  Hz  0.009 

5  A  50  kHz  0.011 

10  A  50  kHz  0.017 

20  A  50  Hz  0.013 

20  A  400  Hz  0.013 

20  A  1  kHz  0.013 

20  A  50  kHz  0.017 

NVLAP  Code:  20/E03 

Capacitance  Dividers  -  Pulsed  High- Voltage  Condition 
Range  Best  Uncertainty  (±)  in  percent"0"1  Remarks 

1  to  350  kV  2.0  1  to  30  Pulse 

NVLAP  Code:  20/E05 
DC  Resistance 

Range  in  ohms  Best  Uncertainty  (±)  in  ppmno,e  1  Remarks 

0.0001  to  0.001  11  Low  Resistance 

0.001  to  0.01  4  Low  Resistance 

0.01  to  0.1  2.5  Low  Resistance 

0.1  to  1  2  Low  Resistance 

1  0.057  Thomas 

1  to  10  1 

10  to  104  0.5 

10  k  0.15  SR104 

105  2 

106  3 

107  5 

108  10 

108  240  with  Teraohmeter 

109  3  30  with  Teraohmeter 

1010  470  with  Teraohmeter 

1011  670  with  Teraohmeter 

1012  1400  with  Teraohmeter 


NVLAP  1999  DIRECTORY  -  Page  Ell 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Range  in  ohms 

1013 
1014 
1015 
1016 


Best  Uncertainty  (±)  in  ppmnotel 

2000 

3300 

6700 

7.0% 


Remarks 
with  Teraohmeter 
with  Teraohmeter 
with  Teraohmeter 
with  Teraohmeter 


Special  Resisters 
2  and  5 
25  and  100 
28.5 


0.5 

0.15 

0.5 


Reichsanstalt 

Tinsley 

NBS 


Shunts 

100  mA  to  1000  A 


2.5 


NVLAP  Code:  20/E06 
DC  Voltage 

Range 

1,  1.018  V 

10.0  V 

1.018  V 

1.0  to  10.0  V 


Best  Uncertainty  (±)  in  ppm"0"1 

0.14 

0.017 

0.21 

0.26 


Remarks 

Josephson  Array  System 
Josephson  Array  System 
Standard  Cell  System 
Zener  Ref.  System 


Voltage  dividers  -  Potentiometer  combination 


1.5  V  to  1500  V 
xl.O  range  to  1.05  V 
xl.O  range  above  1.05  V 
xO.l  range 
xO.Ol  range 


2.5 

0.5  of  reading  +0.1  fiW 
1.0  of  reading  +0.1  /iV 
1.5  of  reading  +0.01  /*V 
2.5  of  reading  +0.005  fiW 


Intermediate  System 
Potentiometer  only,k=3 
Potentiometer  only,k  =  3 
Potentiometer  only,k=3 
Potentiometer  only,k=3 


High  Voltage 
to  100  kV 
100  kV  to  200  kV 
to  10  kV 


106 
140 

0.2% 


200  kV  system 
200  kV  system 
10  kV  system 


NVLAP  1999  DIRECTORY  -  Page  E12 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Ratio/Bridges 
1:1  to  1:100,000 

NVLAP  Code:  20/E08 
Inductive  Dividers 

Range 

15,  35  and  100  V 

NVLAP  Code:  20/E10 
LF  Capacitance 

Range 

0.01  to  1000  pF 

NVLAP  Code:  20/E11 
LF  Inductance 

Range 

10 

20  nE 
50 

100  pH 
200  /jlR 
500  /ill 
1  mH 
2mH 
5  mH 
10  mH 
20  mH 
50  mH 
100  mH 
200  mH 
500  mH 

1  H 

2  H 


0.5  x  107  (ratio)  For  ratio  based  on  20  step  first  dial 

(k=3).  For  bridges,  uncertainty 
combines  ratio  and  resistance 
uncertainties 


Best  Uncertainty  (±)  in  ppm"01" 1  Remarks 

55  @  60,1  k  and  10  kHz 


Best  Uncertainty  ( ±)  in  ppinnole  1  Remarks 
5  @  1  kHz 


Best  Uncertainty  (±)  in  percent"' 
Frequency  in  Hz 


100 

1  k 

10  k 

1.10 

0.20 

0.20 

0.50 

0.20 

0.20 

0.20 

0.20 

0.20 

0.10 

0.10 

0.10 

0.10 

0.10 

0.10 

0.02 

0.02 

0.05 

0.02 

0.02 

0.06 

0.03 

0.03 

0.06 

0.03 

0.03 

0.06 

0.02 

0.02 

0.05 

0.02 

0.02 

0.05 

0.02 

0.02 

0.05 

0.02 

0.02 

0.05 

0.02 

0.02 

0.02 

0.02 

0.02 

0.05 

0.02 

0.05 

NVLAP  1999  DIRECTORY  -  Page  E13 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Range 
5  H 
10  H 


100 

0.02 
0.02 


1  k 

0.10 
0.20 


NVLAP  Code:  20/E18 

Resistive  Dividers  -  Pulsed  High- Voltage  Condition 

Range  Best  Uncertainty  (±)  in  percenf"1 

lto  350  kV  1.0 

TIME  AND  FREQUENCY 

NVLAP  Code:  20/F01 
Frequency  Dissemination 

Range 

0.1  MHz 

1  MHz 

5  MHz 

10  MHZ 


Best  Uncertainty  (±r'e  1 
1  part  in  1012 
1  part  in  1012 
1  part  in  1012 
1  part  in  1012 


Remarks 

1  to  30  fts  Pulse 


Remarks 


IONIZING  RADIATION 

NVLAP  Code:  20/104 
Radioactive  Sources 

Range 

Alpha  Emission  Rate 

1  to  2  x  105  /s  into  27r 
Beta  Emission  Rate 

50  to  5000  Is  into  27T 

Alpha  Energy 

3  to  8  MeV 


Best  Uncertainty  (±)n 


1.6  % 


Remarks 


5.0  % 


30  keV 


MECHANICAL 

NVLAP  Code:  20/M06 
Force 

Range 

100  to  1,000 
1,000  to  100,000 
50  to  30,000 


Best  Uncertainty  (±)  in  percent"0"1, 2' 6 
0.0052 
0.016 
0.075 


Remarks 

Primary  Standard  (Deadweight) 
Secondary  Standards  (Proving  Rings) 
Secondary  Standards  (Load  Cells)"0"  7 


NVLAP  1999  DIRECTORY  -  Page  E14 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


RF  MICROWAVE 


NVLAP  Code:  20/R05 
HF  Capacitance 


Range  in  pF 

0.01 

0.1 

1 

10 

100 

1000 


100 


Best  Uncertainty  (±)  in  percent"01'1 
Frequency  in  Hz 

lk  10  k  100  k 

0.20  1.3 

0.05  1.3 

0.02  0.04 

0.01  0.02 

0.01  0.01 

0.01  0.03 


/  M 


1 

2 

5 

10 

20 


0.02 
0.02 
0.02 
0.10 
0.10 


0.2 

0.35 

0.22 

0.14 

0.13 


0.30 
0.60 
0.26 
0.15 
0.11 


50 

100 

200 

500 

1000 


0.03 
0.02 
0.01 
0.02 
0.02 


0.02 
0.02 
0.01 
0.01 
0.03 


10 
100 


0.0001 
0.0001 


1 

10 

100 

1000 


0.01 
0.01 
0.01 
0.01 


0.01 
0.01 
0.01 
0.01 


0.01 
0.01 
0.01 
0.01 


0.01 
0.01 
0.01 
0.01 


0.01 
0.01 
0.01 
0.01 


NVLAP  1999  DffiECTORY  -  Page  E15 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  Code:  20/R06 
HF  Inductance 

Best  Uncertainty  (±)  in  percent" 
Frequency  in  Hz 


Range 

10  k              100  k 

/  M 

0.1  fiR 

2.19 

4.00 

0.2  fiH 

2.03 

2.03 

0.5  /xH 

0.80 

1.20 

1.0  /xH 

0.56 

0.92 

2.0  MH 

0.31 

0.73 

5.0  ^H 

0.25 

0.68 

10  |uH 

0.39 

0.63 

25  MH 

0.32 

0.16 

50 

0.26 

0.12 

100  uH 

X  \J\J    IX  i  1 

0  "74 

0  1  1 

250  MH 

0.32 

0.16 

500  fiH 

0.26 

0.09 

1  mH 

0.24 

2.5  mH 

0.25 

5  mH 

0.24 

10  mH 

0.29 

25  mH 

0.25 

1.4  1.7  0.8 

0.5  0.9  0.6 

0.4  0.6  0.1 

0.2  0.2 

NVLAP  Code:  20/R10 
Q  Standards 

Range  Best  Uncertainty  (±)  in  percent""' 1  Remarks 

Selected  values  from  95  to  607     1.2  to  4.5  dependent  on  Q  value  and  frequency  frequency  range 

50  kHz  to  45  MHz 


0.25  ^H 
1  ^H 
10  /xH 
100  uH 


1.2 
0.4 
0.4 
0.2 


NVLAP  1999  DIRECTORY  -  Page  E16 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  Code:  20/R11 
RF-DC  Voltage  Converter 

High  Frequency  TVC 


Best  Uncertainty  (±)  in  percent"0 


Frequency  in  Hz 

Range 

1  M 

10  M 

30  M 

50  M 

0.5  V 

0.06 

0.11 

0.21 

0.51 

1  V 

0.06 

0.11 

0.21 

0.51 

2  V 

0.06 

0.11 

0.21 

0.51 

±*  .  U  V 

\J .  \J\J 

n  1 1 

0.21 

0.51 

3  V 

0.06 

0.11 

0.21 

0.51 

5  V 

0.06 

0.11 

0.21 

10  V 

0.06 

0.11 

0.21 

20  V 

0.06 

0.11 

0.21 

50  V 

0.06 

0.11 

0.22 

100  V 

0.06 

0.11 

0.27 

200  V 

0.06 

0.12 

0.21 

00  M 


RF  TVC 


Range 
1  V 
2.4  V 
7  V 


300  M 

1.3 
1.3 
1.3 


Best  Uncertainty  (+)  in  percent™'61 
Frequency  in  Hz 

600  M  700  M  800  M  900  M  1000  M 

1.3  1.3  1.3  1.3  1.3 

1.3  1.3  1.3  1.3  1.3 

1.3  1.3  1.3  1.3  1.3 


Micropotentiometers 


Range  30  M 

0.1  mV  2.32 

0.2  mV  0.54 

0.4  mV  2.34 

0.9  mV  0.54 

1  mV  2.24 


100  M 

3.56 
1.04 
3.44 
1.04 
3.33 


Best  Uncertainty  (±)  in  percent"0'61 
Frequency  in  Hz 


300  M 

3.36 
1.02 
3.18 
1.05 
3.21 


600  M 

5.10 
1.35 
5.10 
1.35 
5.10 


900  M 

5.10 
1.42 
5.10 
1.44 
5.10 


NVLAP  1999  DIRECTORY  -  Page  E17 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Best  Uncertainty  (±)  in  percent"' 
Frequency  in  Hz 


Range 

30  M 

100  M 

300  M 

600  M 

900  M 

1.5  mV 

0.59 

1.02 

1.02 

1.33 

1.33 

4  mV 

0.53 

1.07 

1.21 

1.38 

1.39 

5  mV 

2.24 

3.16 

3.17 

5.10 

5.10 

10  mV 

2.27 

3.19 

3.16 

5.10 

5.10 

11  mV 

2.25 

3.17 

3.58 

5.10 

5.10 

25  mV 

0.48 

0.97 

0.97 

1.28 

1.30 

28.5  mV 

2.52 

3.49 

3.95 

5.10 

102  mV 

0.53 

0.99 

1.08 

1.30 

1.28 

150  mV 

0.43 

0.99 

1.06 

1.32 

1.28 

320  mV 

2.24 

3.23 

3.18 

5.10 

5.10 

330  mV 

0.45 

1.01 

0.98 

1.38 

1.29 

NVLAP  Code:  20/R12 
RF/Microwave  Bolometer  Units 

Expanded  Uncertainties"0"'  '■2J  on  Effective  Efficiency  &  Calibration  Factor  of  HP  bolometric  power  sensors. 

Frequency  (MHz) 


Connector  Quantity 
Type 


N 


APC-3.5 


N 


APC-3.5 


Effective 
Efficiency 

Effective 
Efficiency 


Quantity  50-2000 
Range 


Calibration  0.9  to  1 
Factor 

Calibration  0.9  to  1 
Factor 


0.9  to  1 


0.9  to  1 


0.004-0.006 


0.004-0.005 


2000-8000  8000-12000  12000-18000 

0.004-0.006  0.005-0.007  0.006-0.008 

0.007-0.009  0.009-0.010  0.010-0.011 

0.004-0.005  0.005-0.006  0.006-0.008 

0.007-0.008  0.008-0.009  0.009-0.010 


NVLAP  1999  DniECTORY  -  Page  E18 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  Code:  20/R13 
RF/Microwave  Attenuators 

Reflection  Coefficient  (or  Scattering  Parameter  Sii) 

A.  Dual  6-Port  Network  Analyzer  Certification  Uncertainties  n°'e2<3-4 


Frequency  (MHz) 


Connector 
Type 

Quantity 

Quantity  Range 

50-2000 

2000-8000 

8000-12000 

12000-1 800C 

GR-900 

is,,! 

0  to  1 

0.002-0.009 

0.002-0.015 

N 

!S„| 

0  to  1 

0.002-0.008 

0.002-0.027 

0.006-0.018 

0.006-0.030 

Art_-  / 

1  C  1 

U  tO  1 

0.1)1)2-0.006 

A    AAO    A  AAA 

0.002-0.009 

A    A  A  O    A   A1  O 

0. 003-0. 018 

A   AAT    A    A1  C 

0. 005-0. 015 

APC-3.5 

ISh! 

0  to  1 

0.002-0.012 

0.002-0.015 

0.005-0. 019 

0.012-0.050 

C  D  C\C\(\ 

(jK-yuu 

Arg(Su) 

a  /  1  n    1     -  i 

-180  to  +180 
deg 

A  1  o  a  1  o  a  a 

0.120-180.0 

AA1A  tOAA 

0.019-180.0 

N 

Arg(S„) 

0<|Sii|<l 
-180  to  +180 
deg 

0.360-180.0 

0.300-180.0 

0.600-180.0 

0. 800-180. 0 

APC-7 

Arg(Su) 

o<  !S„!  <1 
-180  to  +180 
deg 

0.012-180.0 

0.200-180.0 

0.540-180.0 

0.525-180.0 

APC-3.5 

Arg(Sn) 

0<jSnj<l 
-180  to  +180 
deg 

0.360-180.0 

0.240-180.0 

0.540-180.0 

0.560-180.0 

B.  HP8510  Vector  Network  Analyzer  Uncertainties 

1 .  Expanded  Uncertainties  note  1,2,3  on  one  or  two-port  devices 


Connector  Quantity 
Type 


N 

APC-7 

APC-3.5 

N 

APC-7 


IS, 


I  °ii 


1  S 

I  ^ii 


Arg(Sn) 
Arg&i) 


APC-3.5  ArgCSii) 


Quantity  Range 

0  to  1 
0  to  1 
0  to  1 

o<!S„!<i 

-180  to  +180  deg 

o<!Sli|<i 

-180  to  +180  deg 

0<|S„|<1 
-180  to  +180  deg 


50-2000 

0.001-0.003 
0.001-0.007 
0.001-0.007 
0.05-180 

0.15-180 

0.53-180 


Frequency  (MHz) 
2000-8000        8000-12000  12000-18000 


0.001-0.009 
0.001-0.003 
0.004-0.020 
0.36-180 

0.16-180 

0.33-180 


0.004-0.009 
0.003-0.007 
0.004-0.020 
1.43-180 

0.33-180 

0.35-180 


0.004-0.021 
0.001-0.004 
0.004-0.020 
1.34-180 

0.38-180 

0.33-180 


NVLAP  1999  DIRECTORY  -  Page  E19 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


2.  Certification  Uncertainties  note2'3-4  on  three-port  devices 


Connector  Quantity  Quantity  50-2000 
Type  Range 


Frequency  (MHz) 
2000-8000  8000-12000 


N,  APC-7,  |S„j 
APC-3.5 

N,  APC-7,  |rge| 
APC-3.5 


0  to  0.3       0.011  -  0.075       0.011  -  0.075      0.03  -  0.09 
0  to  0.3       0.011  -  0.080       0.012  -  0.080      0.030  -  0.084 


12000-18000 

0.050  -  0.092 
0.071  -  0.119 


C.  HP8753  Vector  Network  Analyzer  Certification  Uncertainties  no"  w 
1 .  One  or  two-port  devices 

Quantity  Range 


Connector 
Type 

N 

APC-7 

APC-3.5 

N 

APC-7 
APC-3.5 


Quantity 


1  s 


I  0ii  I 

Arg(Sil) 
Arg(S„) 
Arg(Sli) 


2.  Three-port  devices 
Connector  Type 
N,  APC-7-APC-3.5 
N,  APC-7-APC-3.5 


0  to  1 
0  to  1 
0  to  1 

o<!S„!<i 

-180  to  +180  deg 

0<jSnj<l 
-180  to  +180  deg 

0<jSii|<l 
-180  to  +180  deg 


Quantity 

|rge| 


Quantity  Range 

0  to  0.3 
0  to  0.3 


25-1000 

0.001-0.009 
0.002-0.04 
0.006-0.02 
0.2-70 

0.3-180 

1-180 


1000-3000 

0.003-0.016 
0.002-0.004 
0.006-0.035 
1-180 

0.2-25 

1.6-180 


25-1000  (MHz) 
0.011  -  0.020 
0.01  -  0.03 


D.  Weinschel  VM-4B  Certification  Uncertainties  no,e  2-3-4 


Connector 
Type 

N 

APC-7 
BNC 


Quantity 


1  s 

I  °il 


1  s 


Quantity 
Range 

0  to  1 

0  to  1 

0  to  1 


10-2000 

0.025-0.080 
0.011-0.075 
0.026-0.060no'f5 


Frequency  (MHz) 

2000-8000        8000-12000  12000-18000 

0.031-0.085      0.040-0.090  0.046-0.112 

0.015-0.080      0.030-0.085  0.036-0.106 


NVLAP  1999  DIRECTORY  -  Page  E20 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Attenuation  (or  Scattering  Parameter  Sij) 

A.  Dual  6-Port  Network  Analyzer  Certification  Uncertainties 


Frequency  (MHz) 


Connector 

Quantity 

Quantity 

50-2000 

2000-8000 

8000-12000 

12000-18000 

Type 

Range 

GR-900 

IC  1 

i  Ju  i 

0  to  60  dB 

0.012-0.390 

0.015-0.410 

N 

i  S- 1 
i  °ij  i 

0  to  60  dB 

0.012-0.390 

0.015-0.410 

0.018-0.410 

0.021-0.900 

APC-7 

1  C  1 

l^ij  1 

0  to  60  dB 

0.012-0.390 

0.015-0.410 

0.020-0.410 

0.021-0.900 

APC-3.5 

1  °u  1 

0  to  60  dB 

0.012-0.150 

0.015-0.410 

0.020-0.410 

0.030-0.90 

B.  HP8510  Vector  Network  Analyzer  Uncertainties 

1 .  Expanded  Uncertainties"0'* 1,2,3  on  one  or  two-port  devices 


Frequency  (MHz) 


Connector 
Type 

Quantity 

Quantity  Range 

50-2000 

2000-8000 

8000-12000 

12000-18000 

N 

IC  1 

1  °ij  1 

0  to  60  dB 

0.01-0.12 

0.02-0.17 

0.03-0.25 

0.03-0.48 

APC-7 

1  C  1 

1  °ij  1 

0  to  60  dB 

0.01-0.08 

0.01-0.13 

0.01-0.13 

0.01-0.18 

APC-3.5 

1  C  1 

1  aij  1 

0  to  60  dB 

0.01-0.12 

0.02-0.22 

0.04-0.25 

0.05-0.49 

N 

Arg^) 

0<  |Sy|  <60  dB 
0  to  360  deg 

0.22-1.19 

0.32-1.27 

0.36-1.84 

0.58-3.46 

APC-7 

Arg(Sy) 

0<  | SSJ |  < 60  dB 
0  to  360  deg 

0.22-0.73 

0.25-1.21 

0.41-1.70 

0.57-2.85 

APC-3.5 

Arg(SIJ) 

0<  |Sy|  <60  dB 
0  to  360  deg 

0.45-0.80 

0.35-1.39 

0.41-1.94 

0.66-3.17 

2.  Certification  Uncertainties 

note  2,3,4  on  three-port  devices 

Frequency  (MHz) 

Connector 
Type 

Quantity 

Quantity 
Range 

50-2000 

2000-8000 

8000-12000 

12000-18000 

N,  APC-7, 
APC-3.5 

|  Coupling  [ 
(dB) 

3-40  dB 

0.071  -  0.320 

0.110  -  0.500 

0.012  -  0.500 

0.320  - 
0.600 

N,  APC-7, 
APC-3.5 

j  Mainline  [ 
(dB) 

0  to  8  dB 

0.020  -  0.221 

0.020  -  0.221 

0.020  -  0.221 

0.131  -  .290 

N,  APC-7 
APC-3.5 

|  Directivity 
(dB) 

15-25  dB 

0.19  -  9.2 

0.53  -  9.2 

0.80  -  9.2 

1.55  -  9.2 

N,  APC-7, 

|  Directivity 

30-40  dB 

1.0  -  oo 

2.6  -  oo 

5.7  -  oo 

7.2  -  oo 

APC-3.5 


(dB) 


NVLAP  1999  DIRECTORY  -  Page  E21 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


C.  HP8753  Vector  Network  Analyzer  Certification  Uncertainties"0'* 2,3,4 
1 .  One  or  two-port  devices 


Connector 
Type 

N 

APC-7 

APC-3.5 

APC-3.5 


Quantity        Quantity  Range 


i  c  I 

IC  I 

I  °ij  I 

IC  I 


Arg(S„) 


2.  Three-port  devices 
Connector  Type 

N,  APC-7-APC-3.5 
N,  APC-7-APC-3.5 
N,  APC-7-APC-3.5 
N,  APC-7-APC-3.5 


0  to  60  dB 

0  to  60  dB 

0  to  60  dB 

0<  |Syi  <60  dB 
0  to  360  deg 


Quantity 

Coupling!  (dB) 
Mainlinej  (dB) 
Directivity!  (dB) 
Directivity!  (dB) 


Frequency  (MHz) 
25-1000  1000-3000 


0.003-0.5 
0.002-0.6 
0.003-0.6 
0.4-10 


0.004-1.2 
0.003-0.9 
0.003-1.0 
0.4-10 


Quantity 
Range 

3-20  dB 

0  to  8  dB 

15-25  dB 

30-40  dB 


25-1000  (MHz) 

0.050  -  0.230 
0.020  -  0.050 
0.9  -  3.8 
4-oo 


D.  Weinschel  VM-4B  Certification  Uncertainties nole  2,3,4  on  Attenuation 


Connector 
Type 

N 

APC-7 
BNC 


Quantity 


i  c  I 

I  aij  I 

I  C  I 
I  °ij  I 

I  C  I 

l^ijl 


Quantity 
Range 

0  to  100  dB 

0  to  100  dB 

0  to  100  dB 


10-2000 

0.06-0.60 
0.06-0.60 
0.10-0.90"0"5 


Frequency  (MHz) 
2000-8000  8000-12000 


0.10-1.10 
0.10-1.00 


0.25-1.52 
0.20-1.43 


12000-18000 

0.38-1.80 
0.30-1.75 


E.  Power  Ratio  Attenuation  Expanded  Uncertainties'""* ]'13 


Connector 
Type 


Quantity 


Quantity 
Range 


10-2000 


Fixed  Attenuators  or  Step/Variable  Attenuators 


N,  APC-7 
APC-3.5 


i  c  I 
i  Jij  i 


0  to  11 
dB 


Isolated  Step/Variable  Attenuators 


N,  APC-7 
APC-3.5 


i  c  I 
i  i 


0  to  11 
dB 


0.008-0.014 
+  Mismatch 
Unc. 


0.008-0.014 


Frequency  (MHz) 
2000-8000  8000-12000 


0.014-0.016  + 

Mismatch 

Unc. 


0.014-0.016 


0.013-0.015 
+  Mismatch 
Unc. 


0.013-0.015 


12000-18000 


0.015-0.018 
+  Mismatch 
Unc. 


0.015-0.018 


NVLAP  1999  DDRECTORY  -  Page  E22 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  Code:  20/R16 

Group  Delay  Certification  Uncertainties"0'" 2'3'4 


Connector  Type 
APC-7,  N,  APC-3.5 
APC-7,  N,  APC-3.5 
APC-7,  N,  APC-3.5 
APC-7,  N,  APC-3.5 
APC-7,  N,  APC-3.5 


Typical  Atten.  (dB) 

0.08 

0.21 

0.8 

3 

2.2 


Delay  (ns) 

5 

15 

50 

200 

385 


50-1000  (MHz) 

0.02  -  0.05 
0.04  -  0.13 
0.05  -  0.12 
0.15  -  0.41 
0.46  -  0.50 


NVLAP  Code:  20/R17 
RF/Microwave  Power  Meters 

CW  Power  Certification  Uncertainties"0" 2,3,4 

A.  Low  to  Medium  Power  CW  Microwave  Power  Meter  Calibration  at  Type  N  Connector 

Frequency  (MHz) 
1  to  2000  2000  to  4000        4000  to  12400 


Quantity 

Power  (dBm) 
Power  (dBm) 
Power  (dBm) 


Quantity 
Range 

-30  to  -10 

-10  to  10 

10  to  30 


.09  to  .41  dB 
.06  to  .27  dB 
.06  to  .25  dB 


.13  to  .41  dB 
.10  to  .25  dB 
.10  to  .21  dB 


.14  to  .34  dB 
.11  to  .30  dB 
.11  to  .24  dB 


12400  to  16500 


.16  to  .46  dB 


B.  Low  Power,  Wide  Range,  CW  Microwave  Power  Meter  Calibration  at  Type  N  Connector 

Frequency  (MHz) 

Quantity  Quantity  Range  30  to  4000  4000  to  8000 

Power  (dBm)        -60  to  -50  0.20  to  0.41  dB  0.25  to  0.43  dB 

Power  (dBm)        -50  to -40  0.18  to  0.29  dB  0.23  to  0.35  dB 

Power  (dBm)        -40  to -30  0.14  to  0.25  dB  0.16  to  0.32  dB 

Power  (dBm)         -30  to -20  0.14  to  0.23  dB  0.16  to  0.27  dB 


8000  to  12400 
0.24  to  0.43  dB 
0.22  to  0.35  dB 
0.20  to  0.32  dB 
0.18  to  0.27  dB 


C.  Medium  Power  CW  Microwave  Power  Meter  Calibration  at  Type  N  Connector 

Frequency  (MHz) 

Quantity  Quantity  Range         12  to  1000  240 

Power  (mW)  1  to  10  1.7  to  3.3%   

Power  (mW)  1  to  100     

Power  (mW)  80  to  160    1.9  to  2.4% 


2000  to  2500 


3.1  to  4.3% 


NVLAP  1999  DmECTORY  -  Page  E23 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NYLAP  LAB  CODE  -  continued 

D.  Medium  Power  CW  Microwave  Power  Meter  Calibrations  at  APC-3.5  Connector 

Frequency  (MHz) 

Quantity  Quantity  Range       2000  to  4000  4000  to  8000  8000  to  18000 

Power  (mW)  0.1  to  8  2.8  to  4.0%  3.0  to  4.9%  4.0  to  5.8% 

E.  High  Power  CW  Microwave  Power  Meter  Calibrations  at  Type  N  Connector 

Frequency  (MHz) 

Quantity  Quantity  Range  13.6  to  300  300  to  3000 

Power  (Watts)  0.2  to  10  9.0  to  9.1%  3.3  to  10.6% 

Power  (Watts)  10  to  200  4.4  to  10.1%  9.6  to  10.6% 


Pulse  Power  Certification  Uncertainties"0"  2•3^'' 
A.  Pulse  Power  Meter  Calibrations  at  Type  N  Connector 
Quantity  Quantity  Range 

Power  (mW)  10  to  100 


2000 

7.3  to  8.2% 


THERMODYNAMICS 

NVLAPCode:  20/T04 
Leak  Artifacts 


Range 

Gas  Leak  -  PAV  Technique 

1  x  10"7  moles/s 

1  x  10"8  moles/s 

1  x  10"9  moles/s 

1  x  10"10  moles/s 

Gas  Leak  -  Accumulate  -  Dump  Technique 

1  x  10"10  moles/s  to 
1  x  1014  moles/s 

Gas  Leak  -  Comparison  Technique 
1  x  1010  moles/s 
1  x  10~n  moles/s 
1  x  10"12  moles/s 
1  x  1013  moles/s 
1  x  10"14  moles/s 


Best  Uncertainty  (±)  in  percent10 


0.7 
0.9 
1.0 
1.0 

1.0 


2.5 
2.4 
2.3 
2.3 
7.0 


Remarks 

Total  Gas  Measurement 
Total  Gas  Measurement 
Total  Gas  Measurement 
Total  Gas  Measurement 


1  to  200  Atomic  Mass  Units 
for  any  non-reactive,  non- 
hazardous,  non-radioactive 

gas 


Helium 
Helium 
Helium 
Helium 
Helium 


NYLAP  1999  DIRECTORY  -  Page  E24 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


THERMODYNAMICS 


NVLAP  Code:  20/T05 
Pressure 

Range  Best  Uncertainty  (±)  in  ppmn<"e  1 

Pneumatic  Deadweight  Piston  Gauges  (absolute  mode)  -  Direct  Pressure  Comparison 

0.2  to  24  psia  [  =  1.4  to  170  kPa]  31 

2.0  to  70  psia  [  =  14  to  480  kPa]  28 

52  to  1000  psia  [  =  0.4  to  7.0  MPa]  46 

Pneumatic  Deadweight  Piston  Gauges  (gauge  mode)  -  Direct  Pressure  Comparison 

0.2  to  24  psig  [  =  1 .4  to  170  kPa]  29 

2.0  to  70  psig  [  =  14  to  480  kPa]  26 

52  to  1000  psig  [  =  0.4  to  7.0  MPa]  44 

Hydraulic  Deadweight  Piston  Gauges  (gauge  mode)  -  Direct  Pressure  Comparison 

0.4  to  4.0  kpsig  [  =  2.8  to  28  MPa]  44 

2.0  to  20  kpsig  [  *  14  to  140  MPa]  61 

4.0  to  40  kpsig  [  =  28  to  280  MPa]  59 

Pneumatic  Deadweight  Piston  Gauges  -  Cross  Float  (effective  area) 

0.2  to  24  psig  [  =  14  kPa  to  170  kPa]  35 

2.0  to  70  psig  [  =  14  kPa  to  480  kPa]  33 

52  to  1000  psig  [  =  0.4  MPa  to  7.0  MPa]  46 

Hydraulic  Deadweight  Piston  Gauges  -  Cross  Float  (effective  area) 

0.4  to  4.0  kpsig  [  =  2.8  to  28  MPa]  46 

2.0  to  20  kpsig  [  =  14  to  140  MPa]  67 

4.0  to  40  kpsig  [  =  28  to  280  MPa]  61 

Secondary  Pressure 
Low  Range  Absolute 

Pressure 

0.2  psia  [  =  1.4  kPa] 
1.0  psia  [  =  7.0  kPa] 
6.0  psia  [  =  41  kPa] 
10  psia  [  =  70  kPa] 
15  psia  [  =  100  kPa] 


Best  Uncertainty  (±)  in  psianotel 
0.0013 
0.0013 
0.0017 
0.0021 
0.0028 


Remarks 

Nitrogen 
Nitrogen 
Nitrogen 

Nitrogen 
Nitrogen 
Nitrogen 

Oil 
Oil 
Oil 

Nitrogen 
Nitrogen 
Nitrogen 

Oil 
Oil 
Oil 


Remarks 

Nitrogen 
Nitrogen 
Nitrogen 
Nitrogen 
Nitrogen 


NVLAP  1999  DHtECTORY  -  Page  E25 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Secondary  Pressure 

Low  Range  Gauge  or  Absolute 

Pressure 

20  psi  [  =  140  kPa] 

40  psi  [  =  280  kPa] 

60  psi  [=410  kPa] 

80  psi  [  =  550  kPa] 

100  psi  [  =  690  kPa} 

Secondary  Pressure 
Mid-Range  Gauge  or  Absolute 

Pressure 

200  psi  [  =  1.4  MPa] 

500  psi  [  =  3.4  MPa] 

1.0  kpsi  [  =  7.0  MPa] 

1.5  kpsi  [=10  MPa] 

2.0  kpsi  [  =  14  MPa] 

Secondary  Pressure 
High-Range  Gauge  or  Absolute 

4.0  kspi  [  =  28  MPa] 

6.0  kspi  [  =  41  MPa] 

8.0  kspi  [  =  55  MPa] 

10  kspi  [  =  70  MPa] 


Best  Uncertainty  (±)  in  psino,e  1  Remarks 

0.009  Nitrogen 

0.010  Nitrogen 

0.011  Nitrogen 

0.013  Nitrogen 

0.014  Nitrogen 

Best  Uncertainty  (+)  in  psin0'e  1  Remarks 

0.137  Nitrogen 

0.157  Nitrogen 

0.201  Nitrogen 

0.247  Nitrogen 

0.280  Nitrogen 


0.6  Nitrogen 

0.8  Nitrogen 

1 .0  Nitrogen 

1.0  Nitrogen 


NVLAP  1999  DIRECTORY  -  Page  E26 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


THERMODYNAMICS 

NVLAP  Code:  20/T07 
Resistance  Thermometry 

Temperature  (°C)  Best  Uncertainty  (±)  in  m  °C""el  Material/  Equilibrium 

State 


-189.3442 

0.53 

Ar/Triple  Point 

-38.8344 

0.30 

Hg/Triple  Point 

0.01 

0.16 

H20/Triple  Point 

29.7646 

0.12 

Ga/Melting  Point 

156.5985 

2.00 

In/Freezing  Point 

231.928 

0.92 

Sn/Freezing  Point 

419.527 

1.10 

Zn/Freezing  Point 

660.323 

5.0 

Al/Freezing  Point 

961.78 

10.0 

Ag/Freezing  Point 

Standard  Platinum  Resistance  Thermometer  Calibrations 


-189.3442 

1.1 

Ar/Triple  Point 

-38.8344 

0.6 

Hg/Triple  Point 

0.01 

0.6 

H20/Triple  Point 

29.7646 

0.6 

Ga/Melting  Point 

156.5985 

2.6 

In/Freezing  Point 

231.928 

1.8 

Sn/Freezing  Point 

419.527 

2.0 

Zn/Freezing  Point 

660.323 

5.2 

Al/Freezing  Point 

961.78 

10.1 

Ag/Freezing  Point 

Comparison  Calibrations 


Temperature  Range  (°C) 

Best  Uncertainty  (±)  in  °C0,e  1 

Type  of  Device 

-80  to  0 

0.10 

Thermocouples 

10  to  150 

0.10 

Thermocouples 

150  to  660 

0.22 

Thermocouples 

660  to  700 

0.47 

Thermocouples 

700  to  1100 

2.5 

Thermocouples 

1100  to  1300 

2.8 

Thermocouples 

-80  to  0 

0.06 

RTD/IPRT/PRT 

10  to  150 

0.09 

RTD/IPRT/PRT 

NVLAP  1999  DIRECTORY  -  Page  E27 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Temperature  Range  (°C) 

150  to  660 

-80  to  0 

10  to  150 

-80  to  0 

10  to  150 

150  to  250 


Best  Uncertainty  (±)  in  °C""e  1 
0.21 
0.05 
0.06 
0.06 
0.09 
0.21 


Type  of  Device 
RTD/IPRT/PRT 
Liquid  in  Glass 
Liquid  in  Glass 
Thermistors 
Thermistors 
Thermistors 


Thermocouple  Simulator/Readout  Calibration  Methods 


Type        ITS-90  Temperature  Range 
(°Q 


Best  Uncertainty  (±)  in  °C""e  19 


THERMODYNAMICS 
NVLAP  Code:  20/T10 
Vacuum 

Range 

Ionization  Gage  Reference  for  direct  comparison 

1.3  x  10  6  Pa  <  reading  <  1.3  x 
10"5  Pa 

1.3  x  10 5  Pa  <  reading  <  1.3  x 
lO'4  Pa 

1.3  x  10"4  Pa  <  reading  <  1.3  x 
10"3  Pa 


Best  Uncertainty  ( ±)  in  percent ' 


4.8 


4.7 
4.7  -  2.5 


NIST  Monograph  175 
Reference  Table"0" 10 


K 

-200  TO  1370 

0.10  to  0.30 

7.3.3 

J 

-200  to  1200 

0.08  to  0.22 

6.3.3 

I: 

-240  to  1000 

0.07  to  0.38 

5.3.3 

T 

-240  to  400 

0.09  to  0.53 

9.3.3 

R 

-50  to  1750 

0.38  to  1.09 

3.3.3 

S 

-50  to  1750 

0.43  to  1.02 

4.3.3 

B 

100  to  1750 

0.43  to  4.45 

2.3.3 

C 

0  to  2300 

0.24  to  0.82 

Remarks 

N2;  10"8  torr 
N2;  10"7  torr 


N2;  10"6  torr 


Spinning  Rotor  Gage  Reference  for  direct  comparison 

1.3  x  10"4  Pa  <  reading  <  1.3  x 
10"3  Pa 

1.3  x  10 3  Pa  <  reading  < 
1.3  Pa 


4.3  -  2-1 
2.1 


N2;  10"6  torr 


N2;  10'5  torr 
10"3  torr 


1.3  Pa  <  reading  <  13  Pa 


2.2 


N2;  10"3  torr 


NVLAP  1999  DIRECTORY  -  Page  E28 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Range  Best  Uncertainty  ( ±)  in  percent nole  1  Remarks 

Capacitance  Diaphragm  Gages  Reference  for  direct  comparison 

1.3  x  101  Pa  <  reading  <  2.1  -  0.7  N2;  0.1  torr  range 
13.3  Pa 

13.3  Pa  <  reading  <  133.3  Pa  0.7  N2;  1  torr  range 

133.3  Pa  <  reading  <  1.3  kPa  0.4  N2;  10  torr  range 

1.3  kPa  <  reading  <  13.3  kPa  0.2  N2;  100  torr  range 

13.3  kPa  <  reading  <  0.6  to  0.1  N2;  1000  torr  range 
133.3  kPa 

Secondary  Capacitance  Diaphragm  Gages  Reference  for  direct  comparison 

1.3  x  101  Pa  <  reading  <  2.2  to  0.9  N2;  0.1  torr  range 
13.3  Pa 

13.3  Pa  <  reading  <  133.3  Pa  1.1  N2;  1  torr  range 

133.3  Pa  <  reading  <  1.3  kPa  0.5  N2;  10  torr  range 

1.3  kPa  <  reading  <  13.3  kPa  0.5  N2;  100  torr  range 

13.3  kPa  <  reading  <  13.3  kPa  0.59  to  0.11  N2;  1000  torr  range 


1.  Expanded  uncertainty  with  coverage  factor  of  k=2,  unless  otherwise  specified. 

2.  Approximate  value.  Actual  value  determined  by  test  results. 

3.  The  uncertainty  ranges  are  the  lowest  and  highest  uncertainty  values  within  the  specified  frequency 
range  and  quantity  range. 

4.  Uncertainty  consists  of  an  appropriate  combination  of  the  measurement  uncertainty  (which  includes  all 
significant  sources  of  uncertainty  associated  with  the  calibration  process)  and  uncertainties  due  to  use, 
environment,  handling  or  variation  with  time  over  the  certification  interval. 

5.  Maximum  frequency  for  BNC  is  1000  MHz. 

6.  ASTM  loading  range  classes  (e.g.,  A,  AA)  are  not  used  or  reported. 

7.  Calibrations  to  30,000  lbf  versus  load  cells  can  be  automated;  other  calibrations  are  manual. 

8.  Uncertainties  listed  are  linearized  forms  (A'  +  B'L)  of  uncertainties  calculated  as  root  sum  squares  of 
constant  and  length-dependent  terms  {A2  +  (BL)2}"2.  A'  and  B'  are  calculated  by  fitting  a  straight  line 
through  the  RSS  uncertainty  values  at  the  upper  and  lower  limits  of  range. 

9.  Uncertainty  is  dependent  on  the  specific  temperature  point  tested. 

10.  Referenced  tables  in  NIST  Monograph  175  (April,  1993)  provide  values  for  emf  E  output/input  of  the 
thermocouple  simulator/readout  and  the  Seebeck  coefficient  S  for  the  specific  temperature  points  within 
the  specified  ranges.  The  best  uncertainty  (at  k=2)  of  the  emf  E  in  ptW  is  equal  to  the  product  of 

U  *  S,  where  U  is  the  best  uncertainty  (at  k=2)  of  the  temperature  point  tested. 


NVLAP  1999  DDtECTORY  -  Page  E29 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  105003-0 


MINNESOTA  METROLOGY  LABORATORY 

2277  Hwy.  36 
St.  Paul,  MN  55113-3800 
Contact:  Ms.  Carol  Hockert 
Phone:  651-628-6851     Fax:  651-639-4014 
E-Mail:  chockert@dpsv.state.mn.us 


Accreditation  Valid  Through:  December  31,  1999 

MECHANICAL 

NVLAP  Code:  20/M08 
Mass 

Range 
1000  kg 
500  kg 
300  kg 
200  kg 
100  kg 


Best  Uncertainty  (±)"°'el 
10377  mg 
5069  mg 
3200  mg 
2258  mg 
1299  mg 


Remarks 

Equal  Arm  Balance 
Equal  Arm  Balance 
Equal  Arm  Balance 
Equal  Arm  Balance 
Equal  Arm  Balance 


50  kg  99.7  mg  Double  Substitution 

30  kg  63.0  mg  Double  Substitution 

20  kg  44.6  mg  Double  Substitution 

10  kg  1.634  mg  Double  Substitution 

5  kg  0.247  mg  Double  Substitution 

3  kg  0.156  mg  Double  Substitution 

2  kg  0.106  mg  Double  Substitution 

1  kg  0.036  mg  Double  Substitution 
500  g  0.021  mg  Double  Substitution 
300  g  0.016  mg  Double  Substitution 
200  g  0.014  mg  Double  Substitution 
100  g  0.014  mg  Double  Substitution 
50  g  0.0097  mg  Double  Substitution 
30  g  0.0072  mg  Double  Substitution 
20  g  0.0063  mg  Double  Substitution 
10  g  0.0068  mg  Double  Substitution 
5  g  0.0036  mg  Double  Substitution 

3  g  0.0024  mg  Double  Substitution 

2  g  0.0018  mg  Double  Substitution 


NVLAP  1999  DIRECTORY  -  Page  E30 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Range  Best  Uncertainty  (±)n0!e 1  Remarks 

1  g  0.0016  mg  Double  Substitution 
500  mg  0.00088  mg  Double  Substitution 
300  mg  0.00060  mg  Double  Substitution 
200  mg  0.00048  mg  Double  Substitution 
100  mg  0.00048  mg  Double  Substitution 
50  mg  0.00050  mg  Double  Substitution 
30  mg  0.00046  mg  Double  Substitution 
20  mg  0.00046  mg  Double  Substitution 
10  mg  0.00054  mg  Double  Substitution 
5  mg  0.00034  mg  Double  Substitution 
3  mg  0.00028  mg  Double  Substitution 

2  mg  0.00024  mg  Double  Substitution 

1  mg  0.00028  mg  Double  Substitution 

1000  kg  23203  mg  Tolerance  Test 

500  kg  11335  mg  Tolerance  Test 

300  kg  7155  mg  Tolerance  Test 

200  kg  5049  mg  Tolerance  Test 

100  kg  2904  mg  Tolerance  Test 

50  kg  222.8  mg  Tolerance  Test 

30  kg  140.9  mg  Tolerance  Test 

20  kg  99.6  mg  Tolerance  Test 

10  kg  32.18  mg  Tolerance  Test 

5  kg  1.65  mg  Tolerance  Test 

3  kg  1.61  mg  Tolerance  Test 

2  kg  1.59  mg  Tolerance  Test 
1  kg  1.58  mg  Tolerance  Test 
500  g  1.58  mg  Tolerance  Test 
300  g  1.58  mg  Tolerance  Test 
200  g  0.031  mg  Tolerance  Test 
100  g  0.032  mg  Tolerance  Test 
50  g  0.024  mg  Tolerance  Test 
30  g  0.020  mg  Tolerance  Test 
20  g  0.019  mg  Tolerance  Test 


NVLAP  1999  DIRECTORY  -  Page  E31 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Range  Best  Uncertainty  (±)no'e  1  Remarks 

10  g  0.020  mg  Tolerance  Test 

5  g  0.016  mg  Tolerance  Test 

3  g  0.015  mg  Tolerance  Test 

2  g  0.015  mg  Tolerance  Test 

1  g  0.015  mg  Tolerance  Test 
500  mg  0.0147  mg  Tolerance  Test 
300  mg  0.0146  mg  Tolerance  Test 
200  mg  0.0146  mg  Tolerance  Test 
100  mg  0.0146  mg  Tolerance  Test 
50  mg  0.0146  mg  Tolerance  Test 
30  mg  0.0146  mg  Tolerance  Test 
20  mg  0.0146  mg  Tolerance  Test 
10  mg  0.0146  mg  Tolerance  Test 
5  mg  0.0146  mg  Tolerance  Test 

3  mg  0.0146  mg  Tolerance  Test 

2  mg  0.0146  mg  Tolerance  Test 
1  mg  0.0146  mg  Tolerance  Test 


DIMENSIONAL 


NVLAP  Code:  20/D13 
Surveying  Rods  and  Tapes 


1  -  12  in 


13  -  24  in 


0.004  in 


0.008  in 


Rigid  Rules  (Comparison  to 
Standard) 

Rigid  Rules  (Comparison  to 
Standard) 


1  -  10  ft 
20  ft 
30  ft 
40  ft 
50  ft 
60  ft 
70  ft 
80  ft 
90  ft 


0.0042  ft 
0.0055  ft 
0.0067  ft 
0.0082  ft 
0.0095  ft 
0.0110  ft 
0.0124  ft 
0.0139  ft 
0.0153  ft 


Metal  Tapes  (Bench  Method) 
Metal  Tapes  (Bench  Method) 
Metal  Tapes  (Bench  Method) 
Metal  Tapes  (Bench  Method) 
Metal  Tapes  (Bench  Method) 
Metal  Tapes  (Bench  Method) 
Metal  Tapes  (Bench  Method) 
Metal  Tapes  (Bench  Method) 
Metal  Tapes  (Bench  Method) 


NVLAP  1999  DIRECTORY  -  Page  E32 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Range 
100  ft 
110  ft 
120  ft 
130  ft 
140  ft 
150  ft 
160  ft 
170  ft 

180  ft 
190  ft 
200  ft 

1  -  50  ft 
60  -  100  ft 
110  -  150  ft 
160  -  200  ft 

MECHANICAL 

NVLAP  Code:  20/M12 
Volume  and  Density 

10000  ml 
1000  ml 
100  ml 
10  ml 
1  ml 

100  gal 
50  gal 
25  gal 

5  gal 
1500  gal 


Best  Uncertainty  ( +) 

Remarks 

n  n  1  £o  ft 
u.uioy  it 

Metal  Tapes  (Bench  Method) 

n  nr  qo  ft 

Metal  Tapes  (Bench  Method) 

n  nino  ft 

Metal  Tapes  (Bench  Method) 

(1  nin  ft 

Metal  Tapes  (Bench  Method) 

0.0228  ft 

Metal  Tapes  (Bench  Method) 

0.0242  ft 

Metal  Tapes  (Bench  Method) 

a  nno  ft 
U.Uizo  ft 

Metal  Tapes  (Bench  Method) 

a  moo  ft 

u.uz/o  it 

Metal  Tapes  (Bench  Method) 

0.0212  ft 

Metal  Tape  (Bench  Method) 

n  noas  ft 

Metal  Tape  (Bench  Method) 

n  mm  ft 
U.UjUI  it 

Metal  Tape  (Bench  Method) 

0.0054  ft 

Steel  Tape  (Tape-to-Tape) 

0.0108  ft 

Steel  Tape  (Tape-to-Tape) 

0.0162  ft 

Steel  Tape  (Tape-to-Tape) 

0.0215  ft 

Steel  Tape  (Tape-to-Tape) 

0.6248  ml 

Gravimetric  Method 

0.0628  ml 

Gravimetric  Method 

0.00617  ml 

Gravimetric  Method 

U.OUUoi  ml 

Gravimetric  Method 

0.00010  ml 

Gravimetric  Method 

17.088  ml 

Gravimetric  Method 

13.000  ml 

Gravimetric  Method 

10.160  ml 

Gravimetric  Method 

0.309  in3  Volumetric  Provers  (Volumetric 

Transfer  Method) 

35.372  in3  Large  Volume  Provers  (Volumetric 

Transfer  Method) 


NVLAP  1999  DIRECTORY  -  Page  E33 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Range  Best  Uncertainty  (±)' 

1000  gal  24.243  in3 

500  gal  13.063  in3 

100  gal  3.797  in3 

100  gal  11.97  in3 

THERMODYNAMICS 

NVLAP  Code:  20/T03 
Laboratory  Thermometers 

Triple  Point  of       0.00061  °C 
Water 

10  °C  0.00542  °C 

20  °C  0.00494  °C 

30  °C  0.00502  °C 

40  °C  0.00512  °C 

50  °C  0.00522  °C 

60  °C  0.00532  °C 

70  °C  0.00543  °C 

80  °C  0.00555  °C 

90  °C  0.00568  °C 

100  °C  0.00580  °C 

150  °C  0.00607  °C 

200  °C  0.00754  °C 

250  °C  0.00921  °C 

350  °C  0.01473  °C 


Remarks 

Large  Volume  Provers  (Volumetric 
Transfer  Method) 

Large  Volume  Provers  (Volumetric 
Transfer  Method) 

Large  Volume  Provers  (Volumetric 
Transfer  Method) 

LPG  Provers  (Volumetric  Transfer 
Method) 


Liquid-in-glass,  digital 
thermometers 

Liquid-in-glass,  digital 
thermometers 

Liquid-in-glass,  digital 
thermometers 

Liquid-in-glass,  digital 
thermometers 

Liquid-in-glass,  digital 
thermometers 

Liquid-in-glass,  digital 
thermometers 

Liquid-in-glass,  digital 
thermometers 

Liquid-in-glass,  digital 
thermometers 

Liquid-in-glass,  digital 
thermometers 

Liquid-in-glass,  digital 
thermometers 

Liquid-in-glass,  digital 
thermometers 

Liquid-in-glass,  digital 
thermometers 

Liquid-in-glass,  digital 
thermometers 

Liquid-in-glass,  digital 
thermometers 

Liquid-in-glass,  digital 
thermometers 


NVLAP  1999  DIRECTORY  -  Page  E34 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Range  Best  Uncertainty  (±)"0,e '  Remarks 

400  °C  0.01859  °C  Liquid-on-glass,  digital 

thermometers 

450  °C  0.02252  °C  Liquid-in-glass,  digital 

thermometers 

500  °C  0.02649  °C  Liquid-in-glass,  digital 

thermometers 


1.     Represents  an  expanded  uncertainty  using  a  coverage  factor,  k=2 


NVLAP  1999  DIRECTORY  -  Page  E35 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  105004-0 

U.S.  ARMY  PRIMARY  STANDARDS  LABORATORY 

Attn:  AMSAM-TMD-S 
Redstone  Arsenal,  AL  35898-5000 
Contact:  Dr.  James  R.  Jones 
Phone:  256-876-2666   Fax:  256-876-6014 
E-Mail:  jjones@redstone.army.mil 
URL :  http :  //tmdehome .  redstone .  army,  mil/apsl/ 

Accreditation  Valid  Through:  December  31,  1999 


ELECTROMAGNETICS/DC-LOW  FREQUENCY 
NVLAP  Code:  20/E06 
DC  Volts 

Range  Best  Uncertainty  (±)no'e  1  Remarks 

0  -  10  volts  0.04  ppm  Josephson  Array  System 


TIME  AND  FREQUENCY 


NVLAP  Code:  20/F01 
Frequency 


Range 
0.1  MHz 
1  MHz 
5  MHz 
10  MHz 


Best  Uncertainty  (±)no,el 
1  x  1012 
1  x  1012 
1  x  1012 
1  x  10"12 


Remarks 

NIST  FMS  System 
NIST  FMS  System 
NIST  FMS  System 
NIST  FMS  System 


IONIZING  RADIATION 

NVLAP  Code:  20/104 
Radioactive  Sources 

Range  Best  Uncertainty  (±)"ole  1  Remarks 

0  to  1  x  106  Bq  5%  Large  Area  Sources, 

238Pu,239Pu 


ELECTROMAGNETICS/RF  MICROWAVE 

NVLAP  Code:  20/R12 
RF/Microwave  Bolometer  Units 

Frequency  Calibration  Factor 

0.0001  to  18  GHz  0.7  to  2.0%  Coaxial,  Type  N  Connector 

7  to  10  GHz  2.0%  H  Band  (WR-112)  Waveguide 

8 . 2  to  1 2 . 4  GHz  1.8%  X  Band  WR-90)  Waveguide 

12.4  to  18.0  GHz  2.0%  Ku  Band  (WR-62)  Waveguide 


NVLAP  1999  DIRECTORY  -  Page  E36 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


18.0  to  26.5  GHz  2.5%  K  Band  (WR-42)  Waveguide 

26.5  to  40.0  GHz  2.5%  Ka  Band  (WR-28)  Waveguide 

43.0  to  45.0  GHz  4.0%  Q  Band  (WR-22)  Waveguide 

58.0  to  62.0  GHz  3.0%  V  Band  (WR- 15)  Waveguide 

93 . 0  to  96 . 0  GHz  4.0%  W  Band  (WR- 1 0)  Waveguide 


THERMODYNAMICS 


NVLAP  Code:  20/T07 
Resistance  Thermometry 


Range 

0.01  °c 

-189.3442  to  -38.8344  °C 
29.7646  °C 

231.928  to  419.527  °C 


Best  Uncertainty  (±)no'e  1 
0.001  °c 
0.002  °C 

0.002  °C 
0.002  °C 


Remarks 

Triple  Point  of  Water 

Triple  Point  of  Argon  & 
Mercury 

Melting  Point  of  Gallium 
Freeze  Point  of  Tin  &  Zinc 


1.     Represents  an  expanded  uncertainty  using  a  coverage  factor,  k  =  2 


NVLAP  1999  DIRECTORY  -  Page  E37 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  105007-0 

STATE  OF  VIRGINIA  METROLOGY  LAB 

1  North  14th  Street,  Room  025 

Richmond,  VA  23219-3691 
Contact:  Mr.  Michael  J.  Kramer 
Phone:  804-786-0479    Fax:  804-371-0351 

Accreditation  Valid  Through:  September  30,  1999 

MECHANICAL 

NVLAP  Code:  20/M08 
Mass 


Range 

Best  Uncertainty  (±)no'e 

Remarks 

dUu  kg 

4567  mg 

Tolerance  Test 

3v\)  kg 

456/  mg 

Tolerance  Test 

ZUU  Kg 

z  /  j  j  mg 

Tolerance  Test 

1UU  kg 

z/55  mg 

TU.  1  HP  l 

lolerance  Test 

50  kg 

z /o.y  mg 

lolerance  Test 

30  kg 

277.9  mg 

Tolerance  Test 

25  kg 

277.5  mg 

Tolerance  Test 

20  kg 

277.4  mg 

Tolerance  Test 

10  kg 

277.1  mg 

Tolerance  Test 

5  kg 

277.2  mg 

Tolerance  Test 

3  kg 

277.2  mg 

Tolerance  Test 

2  kg 

1 .56  mg 

Tolerance  Test 

1  kg 

0.576  mg 

Tolerance  Test 

500  g 

0.267  mg 

Tolerance  Test 

300  g 

0.266  mg 

Tolerance  Test 

200  g 

0.266  mg 

Tolerance  Test 

100  g 

0.033  mg 

Tolerance  Test 

50  g 

0.028  mg 

Tolerance  Test 

30  g 

0.027  mg 

Tolerance  Test 

20  g 

0.026  mg 

Tolerance  Test 

10  g 

0.014  mg 

Tolerance  Test 

5g 

0.009  mg 

Tolerance  Test 

3g 

0.008  mg 

Tolerance  Test 

2g 

0.008  mg 

Tolerance  Test 

lg 

0.007  mg 

Tolerance  Test 

500  mg 

0.0048  mg 

Tolerance  Test 

NVLAP  1999  DIRECTORY  -  Page  E38 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Range 

Best  Uncertainty  (±)no" 1 

Remarks 

300  mg 

0.0048  mg 

Tolerance  Test 

200  mg 

0.0047  mg 

Tolerance  Test 

100  mg 

0.0047  mg 

Tolerance  Test 

50  mg 

0.0047  mg 

Tolerance  Test 

30  mg 

0.0047  mg 

Tolerance  Test 

20  mg 

0.0047  mg 

Tolerance  Test 

10  mg 

0.0047  mg 

Tolerance  Test 

5  mg 

0.0047  mg 

Tolerance  Test 

3  mg 

0.0047  mg 

Tolerance  Test 

2  mg 

0.0047  mg 

Tolerance  Test 

1  mg 

0.0047  mg 

Tolerance  Test 

DIMENSIONAL 

NVLAP  Code:  20/D13 
Survey  Rods  and  Tapes 

Range 

Best  Uncertainty  (±)no'e  1 

Remarks 

0  to  25  ft 

0.0015  inches 

Metal  Tapes  (Bench  Method) 

25  to  50  ft 

0.003  inches 

Metal  Tapes  (Bench  Method) 

50  to  75  ft 

0.0045  inches 

Metal  Tapes  (Bench  Method) 

75  to  100  ft 

0.006  inches 

Metal  Tapes  (Bench  Method) 

0  to  25  ft 

0.003  inches 

Steel  Tapes  (Tape  to  Tape) 

25  to  50  ft 

0.006  inches 

Steel  Tapes  (Tape  to  Tape) 

50  to  75  ft 

0.009  inches 

Steel  Tapes  (Tape  to  Tape) 

75  to  100  ft 

0.012  inches 

Steel  Tapes  (Tape  to  Tape) 

MECHANICAL 

NVLAP  Code:  20/M12 
Volume  and  Density 

Range 

Best  Uncertainty  (±yotel 

Remarks 

1.0  gill 

0.002  gill 

Volume  Transfer 

0.5  pint 

0.001  pint 

Volume  Transfer 

1.0  pint 

0.0005  pint 

Volume  Transfer 

1 .0  quart 

0.0002  quart 

Volume  Transfer 

0.5  gallon 

0.0002  gallon 

Volume  Transfer 

NVLAP  1999  DIRECTORY  -  Page  E39  (See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Range 

Best  Uncertainty  (±)nolel 

Remarks 

1.0  gallon 

0.00016  gallon 

Volume  Transfer 

50  mL 

0.13  mL 

Volume  Transfer 

100  mL 

0.26  mL 

Volume  Transfer 

200  mL 

0.26  mL 

Volume  Transfer 

500  mL 

0.26  mL 

Volume  Transfer 

1  Liter 

0.0003  Liter 

Volume  Transfer 

2  Liter 

0.0003  Liter 

Volume  Transfer 

5  Liter 

0.0003  Liter 

Volume  Transfer 

5  gallon 

0.0034  gallon 

Volume  Transfer 

100  gallon 

0.05  gallon 

Volume  Transfer 

>  100  gallon 

0.05  gallon  or  12  in.3 

Volume  Transfer 

THERMODYNAMICS 

NVLAP  Code:  20/T03 
Laboratory  Thermometers 


Range 

0  °C  to  85  °C 


Best  Uncertainty  (±)'""e ' 
0.2  °C 


Remarks 
Liquid-in-glass 


TIME  AND  FREQUENCY 

NVLAP  Code:  20/F01 
Frequency 


Range 

1000  to  6000  Hz 


Best  Uncertainty  (±)no'e  1 
0.047  mph 


Remarks 

Tuning  forks  at  frequencies  used  in 
law  enforcement  converted  to  miles 
per  hour  (mph) 


1.     Represents  an  expanded  uncertainty  using  a  coverage  factor,  k  =  2 


NVLAP  1999  DIRECTORY  -  Page  E40 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NYLAP  LAB  CODE  -  continued 

NVLAP  LAB  CODE  105013-0 

HENRY  TROEMNER,  INC. 

6825  Greenway  Avenue 
Philadelphia,  PA  19142-1294 
Contact:  Mr.  Wilbert  D.  Abele 
Phone:  215-724-0800   Fax:  215-724-9663 
E-Mail:  troemner@troemner.com 
URL:  http://www.troemner.com 

Accreditation  Valid  Through:  September  30,  1999 

MECHANICAL 
NVLAP  Code:  20/M08 
Mass 

Range  Best  Uncertainty  (±)no,e  12  Remarks"01'3 

30  kg  12.41  mg 

20  kg  9.57  mg 

10  kg  1.18  mg 

5  kg  0.59  mg 

3  kg  0.36  mg 

2  kg  0.24  mg 
lkg  0.136  mg 
500  g  0.073  mg 
300  g  0.049  mg 
200  g  0.031  mg 
100  g  0.0167  mg 
50  g  0.0084  mg 
30  g  0.0109  mg 
20  g  0.0075  mg 
10  g  0.0047  mg 
5  g  0.0025  mg 

3  g  0.0016  mg 
2  g  0.0012  mg 
1  g  0.0011  mg 
500  mg  0.0007  mg 
300  mg  0.0006  mg 
200  mg  0.0005  mg 
100  mg  0.0006  mg 
50  mg  0.0004  mg 
30  mg  0.0003  mg 


NVLAP  1999  DIRECTORY  -  Page  E41 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Rptt  IJnrprtnintv  (-\-)no'e1-2 

UCjl    U  lli.  c  /  III  I 11 1  V   (  ~  # 

Remarks'10**  3 

20  mg 

0  0007  mg 

w.www  1  llltl, 

ID  mg 

0  001  0  mg 

U.WVJIVJ  Hlg 

J  lllg 

D  0007  mg 

J  illg 

0  0007  mg 

0  0007  mg 

i  nig 

0  0004  mg 

W  .  WWW  i    I  i  I 

1000  ks 

10  34  g 

f^lacc  TTT  T-^ipilitv 
v. .  itioo  ill  i  civility 

500  kg 

5  03  2 

f^lace  TTT  Papilitv 

vlajj  111  1  dCllliy 

200  kg 

3  26  2 

Ol <s<5  TTT  Parilifv 

v_-  ilioo  ill  i  auiiiiy 

100  kg 

1  64  g 

C^lacc  TTT  P^filitx/ 
wlaoa  HI  .TclV-lliiy 

50  kg 

Kg 

0.087  g 

i  1  q  c q  TTT  T-«ci  c  i 1 1  tv 
V^-laoo  111  .TaCIlHY 

30  ko 

0.072  g 

v^iaso  ill  i^avviillv 

25  ka 

0.066  g 

r^la*?*?  TTT  Facility 

v_- IdO  O   111    1  &W111LV 

20  ks. 

i_W  iv 

0.057  g 

Cla1^  TTT  Facility 

v-'iGoo  in  i  avuny 

10  ks 

0  024  e 

("'la^  TTT  Furilifv 
wifloo  in  i  avuny 

5  kg 

18  30  mg 

r^la<5<?  TTT  Farilitv 

wlaoo  111  1  utility 

3  kg 

J  Kg 

16.77  mg 

r^la^<;  TTT  Facilitv 

\.  IdOO    111    1  CIV  111  LY 

2  kg 

1 1  52  mg 

1  1  .  J-  111-, 

("Mace  TTT  Fapilitv 
V.laoo  111  1  (lv  HI  IV 

1  kg 

10  OQ  mg 

f^l acc  TTT  T-^qpi  1 1 1\/ 

V^laoo  111  laClllly 

500  g 

10  02  mg 

C~*] qcc  TTT  Fq c i  1 1 
Vw-Iaoo  111  i^cLvTlliy 

300  g 

10  01  mg 

A  W  .  W  1  lllil 

r^la<vQ  TTT  Fapilitv 

viaoj  in  i  aviiiiy 

3000  lh 

JuUu  1U 

1  (S  7Q1  g 

(""lace  TTT  T-*QpilitA7 
V^lcioo  111  1  CIVT1HV 

^500  lh 

1 3  ^S1  g 

i  1  qcc  TTT  Fq c i  1 
wiaoo  in  rciV'iiiLy 

9000  lh 

10^1?  g 

I     lQCC    TTT  MQr*lllt"\7 

v_.idoi>  in  raciiiiy 

1000  lh 

lUUu  1U 

d.l  ia  g 

v_.lai»o  ill  Facility 

S00  lh 

JUU  1U 

J  .  O'H- 1  g 

1^ locc  TTT  Th o r* 1 1 1 't\ i 

i^idbb  in  rdciniy 

100  lh 

0  088  g 
u.uoo  g 

t  1  o  c  c  TTT  T^  q  r*  1 1 1  / 
wlaoo  111  FaLllliy 

50  lh 

0  0^4  g 

C^1} cicc  TTT  T--9 r*i  1 1 tv 
wlaoS  111  FaClllLy 

30  lb 

0  04fS  g 

W.WT^W  £i 

r^laQc  TTT  Panlirv 

V/lajj  111  1  a.L.iiiLV 

95  lh 

—  .J  1U 

u.WJJ  ^ 

r^lqcc  TTT  Far*ilitv 
v_.iu.do  in  i  tiLiniy 

20  lb 

0.029  g 

Class  III  Facility 

10  lb 

0.018  g 

Class  III  Facility 

5  lb 

10.572  mg 

Class  III  Facility 

3  lb 

10.127  mg 

Class  III  Facility 

NVLAP  1999  DIRECTORY  -  Page  E42  (See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Range 
2  lb 
1  lb 

0.5  lb 


Best  Uncertainty  (±)note1-2 
10.093  mg 
10.019  mg 
10.005  mg 


Remarks™'"3 
Class  III  Facility 
Class  III  Facility 
Class  III  Facility 


NVLAP  Code:  20/M12 
Volume  -  Pipettes 


Test  Volume  in  nlno'e  5 

Best  Uncertainty  (±)in  \x.l 

0  2 

ft  0477 

0.5 

0.0422 

1.0 

0.0469 

2.5 

0.0860 

5.0 

0.0983 

10 

0.32 

50 

0.52 

100 

0.45 

500 

0.90 

1000 

2.18 

2500 

18.75 

Remarks 


1.  Represents  expanded  uncertainty  using  a  coverage  factor,  k=2. 

2.  Approximate  value.  Actual  value  determined  by  the  test  statistics 

3.  Class  III  Facility  located  at  700  Carpenters  Crossing,  Folcroft,  PA  19032 

4.  Uncertainties  at  specified  test  volumes  may  be  greater  depending  on  the  range  of  the  unit  under  test. 

5.  It  is  recommended  that  adjustable  volume  pipettes  not  be  used  below  10%  of  capacity. 


NVLAP  1999  DDRECTORY  -  Page  E43 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  105014-0 

SOUTHERN  CALIFORNIA  EDISON  COMPANY 

7300  Fenwick  Lane 
Westminster,  CA  92683 
Contact:  Mr.  Jack  Burdick 
Phone:  714-895-0422    Fax:  714-895-0686 
E-Mail:  burdicjj@sce.com 

Accreditation  Valid  Through:  March  31,  1999 


DIMENSIONAL 

NVLAP  Code:  20/D03 
Gage  Blocks 


Range 

thru  1  in 

>  1.0  thru  6.0  in 

7.0  in 

8.0  in 

10.0  in 

12.0  in 

16.0  in 

20.0  in 


Best  Uncertainty  (±)  "0,e  1  &  2 
3.0  itin 

3.0  /xin  +  1  /xin/in 

7.0  ,uin 

7.0  (tin 

7.0  pin 

7.0  itin 

10.0  /lin 

10.0  /xin 


Remarks 

Direct  Comparison 
Direct  Comparison 
Direct  Comparison 
Direct  Comparison 
Direct  Comparison 
Direct  Comparison 
Direct  Comparison 
Direct  Comparison 


MECHANICAL 

NVLAP  Code:  20/M08 
Mass 


Range  Best  Uncertainty  (±)  no'e  1  &  2 

30  kg  42.1  mg 

20  kg  21.6  mg 

10  kg  4.6  mg 

5  kg  2.5  mg 

2  kg  1.8  mg 

1  kg  0.245  mg 

500  g  0.129  mg 

200  g  0.058  mg 

100  g  0.035  mg 

50  g  0.0231  mg 

20  g  0.0142  mg 

10  g  0.0128  mg 

5  g  0.0081  mg 


NVLAP  1999  DIRECTORY  -  Page  E44 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Range  Best  Uncertainty  (±)  "ole  1  &  2  Remarks 

2  g  0.0033  mg 

1  g  0.0029  mg 
500  mg  0.0016  mg 
200  mg  0.0018  mg 
100  mg  0.0007  mg 
50  mg  0.0017  mg 
20  mg  0.0008  mg 
10  mg  0.0006  mg 
5  mg  0.0007  mg 

2  mg  0.0009  mg 
1  mg  0.0005  mg 


ELECTROMAGNETICS  -  DC/LOW  FREQUENCY 

NVLAP  Code:  20/E06 
DC  Voltage 

(±)notej&2  Remarks 

Reference  Cells 

Meters  and  Multifunction  Calibrators 


Range 

10.00  V 
1.018  V 
1.000  V 
100  mV 
1.0  V 
10.0  V 
100.0  V 
1000.0  V 


Best  Uncertainty 
0.28  ppm 
0.20  ppm 
0.46  ppm 
2.6  ppm 
1.1  ppm 

1.0  ppm 

1.1  ppm 

1.2  ppm 


1.  Represents  an  expanded  uncertainty  using  a  coverage  factor,  k=2 

2.  Approximate  value.  Actual  value  determined  by  the  test  statistics. 


NVLAP  1999  DD2ECTORY  -  Page  E45 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  105016-0 

FLUKE  CORPORATION  PRIMARY  STANDARDS  LABORATORY 

6920  Seaway  Boulevard 

P.O.  Box  9090 
Everett,  WA  98206-9090 
Contact:  Mr.  Raymond  D.  Kletke 
Phone:  425-356-5694    Fax:  425-356-5649 
E-Mail:  rdk@tc.fluke.com 

Accreditation  Valid  Through:  June  30,  1999 

ELECTROMAGNETICS  -  DC/LOW  FREQUENCY 

NVLAP  Code:  20/E01 

AC/DC  Difference  for  Low  Frequency  Voltage 

Best  Uncertainty  (±)  in  ppmno,e  1 
Frequency  in  Hertz 


Range 

Level 

10 

20 

40 

100 

lk 

10k 

20k 

50k 

100k 

300k 

500k 

800k 

1M 

22  mV 

2  mV 

940 

740 

350 

740 

340 

730 

740 

350 

860 

1200 

1900 

2100 

2200 

22  mV 

6  mV 

280 

220 

200 

200 

200 

200 

200 

280 

500 

720 

910 

650 

740 

22  raV 

10  mV 

100 

150 

74 

150 

160 

150 

150 

180 

280 

240 

590 

360 

420 

22  mV 

20  mV 

77 

65 

61 

84 

60 

62 

61 

130 

250 

340 

500 

330 

390 

220  mV 

20  mV 

180 

120 

120 

110 

110 

110 

110 

130 

240 

350 

520 

560 

620 

220  mV 

60  mV 

120 

62 

48 

42 

44 

43 

45 

64 

130 

260 

340 

400 

410 

220  mV 

100  mV 

30 

45 

16 

30 

27 

28 

29 

35 

71 

140 

190 

250 

250 

220  mV 

200  mV 

33 

40 

17 

17 

21 

16 

16 

38 

74 

130 

110 

230 

200 

700  mV 

200  mV 

37 

43 

29 

27 

28 

18 

30 

37 

69 

120 

150 

210 

190 

700  mV 

600  mV 

19 

34 

16 

7 

12 

6 

7 

33 

44 

75 

77 

79 

81 

2.2  V 

0.6  V 

19 

33 

25 

15 

15 

15 

9 

33 

44 

88 

93 

94 

98 

2.2  V 

1  V 

77 

30 

13 

7 

11 

11 

11 

31 

37 

74 

89 

91 

75 

2.2  V 

2  V 

84 

30 

19 

6 

7 

6 

6 

31 

38 

87 

90 

76 

77 

7  V 

2  V 

76 

33 

24 

15 

13 

13 

14 

37 

39 

90 

94 

95 

96 

7  V 

3  V 

85 

36 

25 

17 

15 

15 

16 

40 

43 

95 

100 

100 

100 

7  V 

6  V 

82 

29 

20 

7 

7 

7 

6 

31 

37 

89 

90 

75 

76 

22  V 

6  V 

78 

33 

24 

7 

13 

12 

14 

35 

39 

76 

75 

95 

100 

22  V 

10  V 

17 

29 

13 

9 

8 

8 

9 

29 

39 

74 

91 

94 

99 

22  V 

20  V 

16 

29 

20 

8 

7 

7 

8 

28 

38 

88 

90 

75 

76 

70  V 

20  V 

76 

33 

23 

16 

17 

15 

19 

37 

52 

93 

70  V 

30  V 

80 

36 

24 

18 

19 

17 

22 

40 

56 

100 

70  V 

60  V 

16 

30 

20 

12 

12 

15 

12 

35 

43 

74 

NVLAP  1999  DERECTORY  -  Page  E46 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Best  Uncertainty  (±)  in  ppm 
Frequency  in  Hertz 


Range 

Level 

10  20 

40 

100 

lk 

10k 

20k 

50k 

soak  fin 

220  V 

60  V 

75  35 

20 

22 

20 

22 

23 

41 

54  96 

220  V 

100  V 

75  31 

19 

16 

16 

16 

16 

38 

JO 

44 

220  V 

200  V 

22  33 

15 

14 

14 

14 

15 

41 

52 

1000  V 

200  V 

92  44 

33 

19 

16 

25 

30 

38 

61 

1000  V 

600  V 

95  42 

27 

21 

20 

23 

23 

43 

63 

1000  V 

1000  V 

53  22 

20 

19 

21 

23 

28 

55 

80 

NVLAP  Code:  20/E01 

AC/DC  Difference  for  High  Frequency  Thermal  Converters 

Best  Uncertainty 

(±)  in  Percent 

Frequency 

in  Hertz 

Range 

2  M 

10  M 

20  M 

30  M 

50  M 

100  M 

0.5  V 

0.1 

0.2 

0.2 

0.5 

1.0 

1  V 

0.1 

0.2 

0.2 

0.5 

1.0 

2  V 

0.08 

0.16 

0.16 

0.4 

0.8 

3  V 

0.08 

0.1 

0.16 

0.2 

0.5 

1.0 

5  V 

0.1 

0.2 

0.2 

0.5 

1.0 

10  V 

0.1 

0.2 

0.2 

0.5 

1.0 

20  V 

0.1 

0.15 

0.2 

0.5 

1.0 

30  V 

0.08 

0.16 

0.16 

0.4 

0.8 

50  V 

0.08 

0.16 

0.16 

0.4 

0.8 

NVLAP  Code:  20/E01 

AC/DC  Difference  for  Low  Frequency  Thermal  Current  Converters  and  Shunts 

Best  Uncertainty  (±)  in  ppmno,el 
Frequency  in  Hertz 


Range 

10 

20 

40 

400 

lk       5  k          10  k 

20  k 

50  k 

100  k 

10  mA 

80 

80 

120 

200 

20  mA 

200 

80 

50 

80 

50         80  80 

80 

120 

200 

30  mA 

80 

80 

120 

200 

50  mA 

80 

80 

120 

200 

0.1  A 

80 

80 

120 

200 

NVLAP  1999  DD2ECTORY  -  Page  E47 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Best  Uncertainty  (±)  in  ppni 
Frequency  in  Hertz 


Range 

1U  ZU 

4  (J 

400 

i  k 

5  k 

7/1  I- 

50  k 

100  k 

A  O  A 
V.I  A 

O  CA  OA 

c  n 

3U 

80 

5U 

80 

80 

80 

120 

200 

a  i  a 

80 

80 

1  1A 

120 

200 

a  ^  a 
(J.J  A 

80 

on 
80 

120 

200 

1.0  A 

80 

80 

120 

200 

2.0  A 

80 

80 

80 

80 

80 

80 

120 

200 

3.0  A 

80 

80 

120 

200 

5.0  A 

80 

80 

120 

200 

10.0  A 

80 

110 

80 

110 

110 

120 

200 

20.0  A 

110 

110 

200 

NVLAP  Code:  20/E02 
AC  Current 

For  Calibrators  or  DMMs 

Best  Uncertainty  (±)  in  pprn 
Frequency 


Current 

10  Hz 

20  Hz 

40  Hz 

400  Hz 

1  kHz 

5  kHz 

10  kHz 

19  (J.A 

250 

200 

200 

200 

200 

250 

250 

100  ^A 

160 

90 

70 

70 

70 

150 

200 

190  jiA 

150 

85 

57 

60 

55 

150 

200 

1  mA 

150 

80 

50 

50 

50 

80 

100 

1.9  mA 

150 

80 

50 

50 

41 

70 

90 

10  mA 

260 

90 

85 

85 

85 

85 

100 

19  mA 

260 

85 

51 

85 

51 

85 

100 

100  mA 

260 

90 

85 

85 

85 

85 

100 

190  mA 

260 

85 

51 

85 

51 

85 

100 

1.0  A 

85 

85 

85 

100 

150 

1.9  A 

85 

85 

85 

100 

150 

10  A 

85 

115 

85 

120 

150 

NVLAP  1999  DERECTORY  -  Page  E48 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  Code:  20/E02 
AC  Current 
5500A  Console 

Best  Uncertainty  (+)  in  ppm 
Frequency  in  Hz 


Range 

10 

45 

65  500 

1  k 

5  k 

10k 

33  nA 

180 

600 

190  fiA 

70 

80 

470 

329  fiA 

80 

60 

80 

150 

330 

330  ^A 

160 

180 

1.9  mA 

60 

100 

3.29  mA 

80 

60 

60 

80 

90 

3.3  mA 

140 

150 

1  Q  m  A 

OU 

yo 

32.9  mA 

130 

65 

65 

80 

90 

33  mA 

85 

90 

190  mA 

60 

90 

329  mA 

130 

65 

65 

80 

90 

330  mA 

85 

1  r\r\ 

100 

2.19  A 

130 

70 

70 

80 

2.2  A 

100 

100 

11  A 

90 

90  100 

130 

NVLAP  Code:  20/E02 
AC  Current 

At  Factory  Annex  -  Multifunction  Calibrators  Similar  to  Fluke  5720A 

Best  Uncertainty  (±)  in  ppmno'e  1 

Frequency  in  Hz 

Range 

40 

1  k 

10  k 

19  fiA 

210 

1050 

190  MA 

53 

53 

260 

1.9  mA 

46 

260 

19  mA 

53 

260 

190  mA 

43 

53 

260 

1.9  A 

90 

90 

1000 

NVLAP  1999  DDRECTORY  -  Page  E49 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  Code:  20/E02 
AC  Current 

At  Factory  Annex  -  Multiproduct  Calibrators  Similar  to  Fluke  5500A 


Best  Uncertainty  (±)  in  ppm™'"1 
Frequency  in  Hz 


Range 

10 

45 

65 

500 

/  k 

5  k 

10k 

33  jtA 

1400 

2200 

190  nA 

270 

360 

1600 

329  MA 

380 

220 

270 

560 

1600 

330  ixh 

270 

390 

1.9  mA 

170 

750 

3.29  mA 

320 

140 

140 

260 

730 

3.3  mA 

260 

390 

19  mA 

150 

750 

32.9  mA 

350 

140 

140 

260 

740 

33  mA 

260 

390 

190  mA 

170 

750 

329  mA 

350 

140 

140 

250 

740 

330  mA 

279 

1300 

2.19  A 

410 

150 

210 

1200 

2.2  A 

300 

550 

11  A 

110 

120 

160 

430 

NVLAP  Code:  20/E05 
DC  Resistance 


Range  in  ohms 
0.01  to  <0.1 
0.1  to  <1 

I  to  <  1 1 

II  to  <  110 
110  to  <190 
190  to  <  11  k 
11  k  to  <19  k 
19  k  to  <  1 10  k 


Best  Uncertainty  (±)  in  ppmnotel 

10 

.5 

0.3 

0.35 

0.45 

0.4 

0.45 

0.4 


Remarks 
Guildline  Bridge 
Guildline  Bridge 
Guildline  Bridge 
Guildline  Bridge 
Guildline  Bridge 
Guildline  Bridge 
Guildline  Bridge 
Guildline  Bridge 


NVLAP  1999  DIRECTORY  -  Page  E50 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Range  in  ohms  Best  Uncertainty  (±)  in  ppm"°'e  1  Remarks 

110  k  to  <  1.1  M        1.2  Guildline  Bridge 

1  0.5  Low  Ohm  System 

10  0.6  Low  Ohm  System 

100  0.75  Low  Ohm  System 

lk  0.6  Low  Ohm  System 

10  k  0.75  Low  Ohm  System 


NVLAP  Code:  20/E05 
DC  Resistance 


Range  in  ohms 

Best  Uncertainty  (±)  in  ppmnoUl 

Remarks 

1 

12 

5700A 

Console 

1.9 

10 

5700A 

Console 

10 

5 

5700A 

Console 

19 

4 

5700A 

Console 

100 

3 

5700A 

Console 

190 

2 

5700A 

Console 

1  k 

2 

5700A 

Console 

1.9  k 

2 

5700A 

Console 

10  k 

0.5 

5700A 

Console 

19  k 

1 

5700A 

Console 

100  k 

2 

5700A 

Console 

190  k 

2.5 

5700A 

Console 

1  M 

3 

5700A 

Console 

1.9  M 

3.5 

5700A 

Console 

3  M 

4 

5700A 

Console 

10  M 

4.5 

5700A 

Console 

19  M 

6 

5700A 

Console 

30  M 

15 

5700A 

Console 

100  M 

25 

5700A 

Console 

300  M 

60 

5700A 

Console 

NVLAP  1999  DIRECTORY  -  Page  E51 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 

NVLAP  Code:  20/E05 
DC  Resistance 


Range  in  ohms 

Best  Uncertainty  (±)  in  ppmmtel 

Remarks 

0 

100 

5500A  Console 

2.0 

55 

5500A  Console 

10.9 

25 

5500A  Console 

11.9 

25 

5500A  Console 

L9 

70 

5500A  Console 

30 

70 

5500A  Console 

33 

40 

5500A  Console 

109 

21 

5500A  Console 

119 

17 

5500A  Console 

190 

13 

5  500 A  Console 

300 

12 

5500A  Console 

330 

11 

5500A  Console 

1.09  k 

10 

5500A  Console 

1.19  k 

10 

5500A  Console 

1.9  k 

13 

5500A  Console 

3  k 

12 

5500A  Console 

3.3  k 

11 

5500A  Console 

10.9  k 

10 

5500A  Console 

11.9  k 

10 

5500A  Console 

19  k 

12 

5500A  Console 

30  k 

12 

5500A  Console 

33  k 

11 

5500A  Console 

109  k 

10 

5500A  Console 

119  k 

10 

5500A  Console 

190  k 

24 

5500A  Console 

300  k 

20 

5500A  Console 

330  k 

20 

5500A  Console 

1.09  M 

16 

5500A  Console 

1.19  M 

15 

5500A  Console 

1.9  M 

8 

5500A  Console 

3  M 

8 

5500A  Console 

3.3  M 

85 

5500A  Console 

10.9  M 

62 

5500A  Console 

NVLAP  1999  DIRECTORY  -  Page  E52 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NYLAP  LAB  CODE  -  continued 


Range  in  ohms  Best  Uncertainty  (±)  in  ppmnote  1  Remarks 

11.9  M  61  5500 A  Console 

19  M  30  5500A  Console 

30  M  30  5500A  Console 

33  M  550  5500A  Console 

109  M  525  5500A  Console 

119  M  525  5500A  Console 

290  M  100  5500A  Console 


NVLAP  Code:  20/E05 
Resistance 

At  Factory  Annex  -  Multifunction  Calibrators  Similar  to  Fluke  5720A 


Range  in  ohms 

Best  uncertainty  {+)  in  pptn 

Remarks 

1 

24.0 

5720A  Console 

1.9 

20.0 

5720A  Console 

10 

10.0 

5720A  Console 

19 

8.4 

5720A  Console 

100 

3.2 

5720A  Console 

190 

2.6 

5720A  Console 

1  k 

3.0 

5720A  Console 

1.9  k 

2.5 

5720A  Console 

10  k 

2.0 

5720A  Console 

19  k 

2.2 

5720A  Console 

100  k 

2.2 

5720A  Console 

190  k 

2.4 

5720A  Console 

1  M 

4.0 

5720A  Console 

1.9  M 

4.7 

5720A  Console 

10  M 

8.0 

5720A  Console 

19  M 

10.5 

5720A  Console 

100  M 

35.5 

5720A  Console 

NVLAP  1999  DIRECTORY  -  Page  E53 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  Code:  20/E05 
DC  Resistance 

At  Factory  Annex  -  Multifunction  Calibrators  Similar  to  Fluke  5500A 


If  mi  op  in  nhtnv 

JTYli/fct    III  K/Illllo 

dl  si  u  HLt f  iiiifiiy  [  i/  in  jjuiti 

lyCfflurtiA 

2 

100 

JJUV/A  V_^UlloUlC 

10.9 

40 

J  JUUA  V^-UlloUlC 

1 1  9 

40 

JJUUA  V^UIlbUlC 

1  Q 

jjuuA  v^unbuic 

30 

90 

JJUUA  V-.U11&U1C 

33 

SO 

j  w 

JJUUA  V^UlloUlC 

109 

40 

JJUL/A  Y_-UlloUlC 

1 19 

1  1  .7 

20 

JJUUA  V_,UlIoUlC 

190 

20 

SSDOA  PotkoIp 

JJUUA  V^UHoUlC 

3  Of) 

jjuua  \--uiJoUic 

33f) 

1  s 

SSOOA  Prmcnlp 
JJUUA  Y^UIldUlC 

1   1  k 

1.1  IV 

1  s 

1  J 

jjuua  y^uu&uic 

1.2  k 

J JUU/ \  v^UllSWlt 

1 .9  k 

JJUUA  V_^UlloUlC 

3  k 

J  rv 

JJUUA  V^UiloUlC 

1   ^  \k 
J.J  IS. 

1  5 

SSOOA  Pnncnlp 
JJUUA  v^UIioUlC 

10  9 

1  S 

JJUUA  V_.ULloUlC 

1 1  .y 

1  s 

1  J 

JJUUA  V_-UlloUlC 

1  Q  k 
i  y  k 

1  s 

JJUUA  V_,UlloUlC 

JU  K 

JJUUA  Y^UlloUiC 

33  k 

1  J 

JJuUA  V^UlloL/lt 

109  k 

1  s 

1  .J 

SSOOA  Console 

J  JuvA  Y^*J11jU1G 

1  1 Q  V 

1  s 

1  J 

SSOOA  Pnncnlp 
Jj\J\Jr\  Y-,UII;>U1C 

1  QO  V 

-  J 

JJUUA  v^OIlbOlt. 

^oo  v 

Z.J 

JJUUA  V-,UlloUlC 

JJU  K 

Is 

£  J 

JJUUA  y^UIIMJIC 

1.1  M 

25 

5500A  Console 

1.2  M 

25 

5500A  Console 

1.9  M 

25 

5500A  Console 

3.0  M 

25 

5500A  Console 

3.3  M 

100 

5  500 A  Console 

10.9  M 

100 

5500A  Console 

NVLAP  1999  DIRECTORY  -  Page  E54 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


DC  Current 


DC  Current 


Range  in  ohms 

Best  Uncertainty  (±)  in  ppmncte  1 

Remarks 

11.9  M 

100 

5500A  Console 

19  M 

100 

5500A  Console 

30  M 

100 

5500A  Console 

33  M 

800 

5500A  Console 

109  M 

800 

5500A  Console 

119  M 

800 

5500A  Console 

290  M 

800 

5500A  Console 

20/E05 

Range 

Best  Uncertainty  (±)  in  ppm"""1 

Remarks 

to  19  uA 

10 

Calibrators  or  DMMs 

100  nA  to  190  fiA 

4 

Calibrators  or  DMMs 

1.0  mA  to  1.9  mA 

4 

Calibrators  or  DMMs 

10  mA  to  19  mA 

9 

Calibrators  or  DMMs 

100  mA  to  190  mA 

10 

Calibrators  or  DMMs 

1.0  A 

11 

Calibrators  or  DMMs 

1.9  A 

10 

Calibrators  or  DMMs 

10  A 

22 

Calibrators  or  DMMs 

20/E05 

Range  in  ( ±)  Ampheres 

Best  Uncertainty  (±)  in  ppmnotel 

Remarks 

0 

3  (nA) 

5500A  Console 

190  fx 

8 

5500A  Console 

1.9  m 

7 

5  500 A  Console 

3.29  m 

7 

5500A  Console 

19  m 

7 

5500A  Console 

32.9  m 

7 

5500A  Console 

190  m 

8 

5500A  Console 

329  m 

8 

5500A  Console 

2.19  m 

14 

5500A  Console 

11 

30 

5500A  Console 

NVLAP  1999  DHUECTORY  -  Page  E55 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  Code:  20/E05 
DC  Current 

At  Factory  Annex  -  Multifunction  Calibrators  Similar  to  Fluke  5720A 


Range 

Best  Uncertainty  (±)  in  ppmnote  1 

Remarks 

19  nA 

100 

5720A  Console 

190  fiA 

28 

5720A  Console 

-190  nA 

16 

5720A  Console 

±19  mA 

8 

5720A  Console 

±19  mA 

12 

5720A  Console 

100  mA 

12 

5720A  Console 

±190  mA 

12 

5720A  Console 

1  A 

19 

5720A  Console 

±1.9  A 

16 

5720A  Console 

NVLAP  Code:  20/E05 
DC  Current 

At  Factory  Annex  -  Multifunction  Calibrators  Similar  to  Fluke  5500A 

Range  (±)  Ampheres 

Best  Uncertainty  (±)  in  ppmno'e  1 

Remarks 

190  fi 

58 

5500A  Console 

1.9  m 

32 

5500A  Console 

3.3  m 

29 

5500A  Console 

19  m 

21 

5500A  Console 

32.9  m 

20 

5500A  Console 

190  m 

42 

5500A  Console 

329  m 

40 

5  500 A  Console 

2.29 

40 

5500A  Console 

1 1 

65 

5500A  Console 

NVLAP  Code:  20/E06 
DC  Voltage 


Reference  Standards 


Range 

10.00  V 
10.00  V 


Best  Uncertainty  ( ±)" 

0.02  ppm"°'e2 
0.06  ppm"0^ 


Remarks 


Direct  Comparison  -  in  lab 

Direct  Comparison  -  remote 
location 


NVLAP  1999  DIRECTORY  -  Page  E56 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Well  Isolated  DC  Sources  or  Voltmeters 

200  fiW  to  10  V 

>  10  V  to  100  V 

>  100  V  to  1000  V 


(0.02  +  0.1E02)  hV'>°"2'3 
0.5  ppm"0"2 
0.7  ppm"0"2 


Direct  against  J  Array 
J  Array  &  Divider 
J  Array  &  Divider 


Calibrators  or  Digital  Voltmeters 

0.1  V 
1.0  V 
10.0  V 
100.0  V 
1000.0  V 

NVLAP  Code:  20/E06 
DC  Voltage 


3.0  ppm 
0.8  ppm 
0.3  ppm 
0.5  ppm 
0.8  ppm 


Transfer  Method 
Transfer  Method 
Transfer  Method 
Transfer  Method 
Transfer  Method 


Range  in  (±)  Volts 
0 

0.329 

3.29 

32.9 

50 

329 

334 

900 

1020 


Best  Uncertainty  (±)  in  ppm"0" 1  Remarks 

0.5  5500A  Console 

7.0  5500A  Console 

5.5  5500A  Console 

8.0  5500A  Console 

8.0  5500A  Console 

8.0  5 500 A  Console 

8.5  5500 A  Console 

7.0  5500A  Console 

7.0  5500A  Console 


NVLAP  Code:  20/E06 
DC  Voltage 

At  Factory  Annex  -  Multifunction  Calibrators  Similar  to  Fluke  5720A 


Range 
100  mV 
-100  mV 
±1.0  V 
±10.0  V 
±100.0  V 
±1000.0  V 


Best  Uncertainty  (±)  in  ppm" 
5.0 
6.5 
1.2 
0.7 
1.0 
1.4 


Remarks 
5720A  Console 
5720A  Console 
5720A  Console 
5720A  Console 
5720A  Console 
5720A  Console 


NVLAP  1999  DIRECTORY  -  Page  E57 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  Code:  20/E06 
DC  Voltage 

At  Factory  Annex  -  Multiproduct  Calibrators  Similar  to  Fluke  5500A 


Range  in  (±)  Volts  Best  Uncertainty  (±)  in  ppmnotel  Remarks 

0.329  8  5500A  Console 

3.29  7  5500 A  Console 

32.9  10  5500A  Console 

50  9  5500A  Console 

329  9  5500A  Console 

334  10  5500A  Console 

900  9  5500A  Console 

1020  9  5500A  Console 


NVLAP  Code:  20/E09 
LF  AC  Voltage 

Best  Uncertainty  in  ppm  (±)' 
Frequency  in  Hertz 


Range 

10 

20 

40 

100 

Ik 

10k 

20k 

50k 

100k 

300k 

500k 

800k 

1  M 

2  mV 

1000 

840 

520 

840 

510 

830 

840 

520 

940 

1300 

2000 

2200 

2300 

6  mV 

310 

260 

240 

240 

240 

240 

240 

320 

520 

740 

920 

670 

760 

10  mV 

130 

170 

110 

170 

180 

170 

170 

200 

300 

260 

600 

370 

430 

20  mV 

89 

78 

76 

95 

75 

76 

76 

140 

260 

350 

510 

340 

400 

60  mV 

130 

65 

52 

46 

48 

47 

49 

67 

130 

280 

340 

400 

410 

100  mV 

36 

47 

22 

33 

31 

32 

32 

38 

73 

140 

190 

250 

250 

200  mV 

35 

42 

20 

20 

24 

20 

19 

40 

75 

130 

110 

230 

200 

600  mV 

20 

35 

18 

10 

14 

10 

10 

33 

44 

76 

78 

80 

82 

1  V 

77 

31 

15 

10 

13 

13 

13 

31 

38 

74 

89 

91 

75 

2  V 

84 

31 

20 

9 

9 

9 

9 

32 

38 

88 

90 

77 

77 

3  V 

85 

37 

26 

18 

16 

16 

17 

40 

43 

95 

100 

100 

100 

6  V 

82 

30 

21 

9 

9 

9 

8 

32 

38 

89 

90 

75 

76 

10  V 

18 

29 

14 

10 

9 

9 

10 

29 

39 

74 

91 

94 

99 

20  V 

17 

29 

21 

10 

9 

9 

10 

28 

38 

88 

90 

75 

76 

30  V 

81 

37 

26 

20 

21 

19 

24 

41 

57 

100 

60  V 

18 

31 

22 

14 

14 

16 

14 

36 

44 

74 

100  V 

76 

32 

20 

18 

17 

17 

18 

39 

44 

NVLAP  1999  DIRECTORY  -  Page  E58 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Best  Uncertainty  in  ppm  (±)no,e  1 
Frequency  in  Hertz 


Range 

10 

20 

40 

100 

Ik 

10k 

20k 

50k 

100k 

200  V 

23 

33 

16 

15 

16 

15 

16 

41 

52 

600  V 

95 

43 

29 

22 

22 

24 

25 

44 

64 

1000  V 

54 

23 

22 

21 

23 

24 

29 

58 

81 

300k    500k    800k    1  M 


NVLAP  Code:  20/E09 
AC  Voltage 

Multiproduct  Calibrators  Similar  to  Fluke  5500A 

Best  Uncertainty  (±)  in  ppm"0" 1 
Frequency  in  Hertz 


Range  in 
Volts 

9.5 

10 

45 

1  k 

5k 

8  k    10  k 

18  k 

20  k 

50  k 

90  k     100  k 

450  k     500  k 

0.01 

250 

250 

250 

250 

0.03 

800 

250 

100 

100 

100 

100 

160 

270 

750 

0.3 

800 

170 

30 

30 

30 

35 

50 

80 

300 

3.0 

800 

160 

25 

25 

25 

25 

50 

70 

350 

30 

800 

160 

25 

25 

25 

25 

50 

100 

300 

35 

35 

35 

45 

1000 

35 

35 

35 

35 

NVLAP  Code:  20/E09 
AC  Voltage 

At  Factory  Annex  -  Multifunction  Calibrators  Similar  to  Fluke  5720A 

Best  Uncertainty  (±)  in  ppm' 
Frequency  in  Hertz 


Range 

40 

50 

1  k 

20  k 

100  k 

300  k     500  k 

/  Mhz 

1.9  mV 

740 

840 

19  mV 

90 

90 

90 

270 

420 

1100 

190  mV 

30 

60 

80 

130 

240 

740 

600  mV 

30 

20 

20 

50 

130 

500 

1  V 

20 

10 

10 

50 

100 

400 

2  V 

20 

20 

400 

3  V 

30 

20 

20 

50 

180 

670 

10  V 

20 

10 

10 

40 

140 

400 

NVLAP  1999  DDiECTORY  -  Page  E59 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NYLAP  LAB  CODE  -  continued 


Best  Uncertainty  (±)  in  ppmn<"el 
Frequency  in  Hertz 


Range 

in 
40 

1  K 

20  K 

100  k 

j(JU  k 

500  k 

1  Mhz 

1    Q  i-n  V 

i  .y  m v 

o4U 

20  V 

10 

10 

400 

30  V 

30 

20 

20 

60 

330 

1700 

100  V 

20 

20 

20 

50 

200  V 

25 

20 

60 

500  V 

30 

20 

1100  V 

25 

30 

NVLAP  Code:  20/E09 
AC  Voltage 

At  Factory  Annex  -  Multiproduct  Calibrators  Similar  to  Fluke  5500A 

Best  Uncertainty  (±)  in  ppmR0'e ' 
Frequency  in  Hertz 


Range 

10 

45 

lk          5  k          10  k 

20  k 

50  k        100  k      500  k 

0.03  V 

300 

180 

180  180 

180 

250         350  900 

0.3  V 

180 

27 

27  27 

27 

50           75  380 

3.0  V 

180 

27 

27  27 

27 

50          75  380 

30  V 

160 

30 

30  30 

30 

55  100 

300  V 

50 

40  40 

60 

1000  V 

50 

50           50           50n<"e  4 

NVLAP  Code:  20/E10 

Capacitance 

Three  Wire 

Best  Uncertainty  (±)no,e  1 

Frequency  in  Hertz 

Range 

1  k 

10  k 

1.0  pF  to  1.1111  fiF 

0.01% 

+  (0.002%  *  C  juF)  f2  kHz 

0.01%  +  (0.002%  *  C  fiF)  f  kHz 

1.0  pF  to  0.001  /*F 

0.01% 

0.01% 

0.001  ^F  to  0.01  ^F 

0.01% 

0.012% 

0.01  /*F  to  0.05  /iF 

0.01% 

0.02% 

NVLAP  1999  DIRECTORY  -  Page  E60 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Best  Uncertainty  (±)note  1 
Frequency  in  Hertz 


Range 

1  k 

10  k 

0.05  fiF  to  0.1  fiF 

0.01% 

0.03% 

0.1  (jlF  to  0.5  tiF 

0.011% 

0.11% 

0.5  iiF  to  1.11  t*F 

0.012% 

0.21% 

Two  Wire 

lOpFto  1.1111  fj.F 

0.01%  +  (0.002%  *  C  itF)F2  kHz  +  0.5  pF  0.01% 

+  (0.002%  *  C 
pF 

10  pF 

5% 

5% 

100  pF 

0.5% 

0.5% 

1000  pF 

0.06% 

0.06% 

0.01  fiF 

0.015% 

0.017% 

0.1  fiF  to  1  fiF 

0.015% 

0.017% 

NVLAP  Code:  20/E10 
Capacitance 

Range 

Best  Uncertainty  (±)  in  ppmnote  1 

Remarks 

3jv  pr 

@  1000  Hz 

2500 

jjUUA  Console 

/ion  «"c 
4o(J  pr 

@  1000  Hz 

2100 

jjUUA  Console 

/TAA   

600  pr 

@  1000  Hz 

1300 

jjUOA  Console 

1  nF  @ 

1000  Hz 

1000 

jjUOA  Console 

2  nF  @ 

1000  Hz 

800 

jjUUA  Console 

7  nf  @ 

1000  Hz 

710 

zoUUA  Console 

10.9  nF 

@  1000  Hz 

700 

jjUUA  Console 

20  nF  (q 

) 1000  Hz 

700 

CCAA  A                 „  — .1™ 

jjUUA  Console 

7(J  nr  (g 

)  1000  Hz 

690 

jjUUA  console 

/1AA   ¥™7 

200  nr 

@  1000  Hz 

690 

jjUUA  console 

300  nF 

@  1000  Hz 

680 

5500A  Console 

700  nF 

@  100  Hz 

680 

5500A  Console 

2  MF  @ 

100  Hz 

690 

5500A  Console 

3  /xF  @ 

100  Hz 

690 

5500A  Console 

7  /xF  @ 

100  Hz 

690 

5500A  Console 

10.9  /iF 

@  100  Hz 

690 

5500A  Console 

20  iiF  (2 

P  100  Hz 

700 

5500A  Console 

NVLAP  1999  DntECTORY  -  Page  E61 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Range 

30  fiF  @  100  Hz 
70      @  100  Hz 
200  /xF  @  100  Hz 
300  /xF  @  100  Hz 
330      @  50  Hz 
1 . 1  mF  @  50  Hz 


Best  Uncertainty  (±)  in  ppmno'el 

710 

740 

1400 

1500 

1600 

2400 


Remarks 
5  500 A  Console 
5500A  Console 
5500A  Console 
5500A  Console 
5500A  Console 
5500A  Console 


NVLAP  Code:  20/E10 
Capacitance 


At  Factory  Annex  -  Multiproduct  Calibrators  Similar  to  Fluke  5500A 


Range 

Best  Uncertainty  (±)  in  ppmnolel 

Remarks 

350  pF  @  1000  Hz 

3200 

5500A  Console 

480  pF  @  1000  Hz 

3000 

5500A  Console 

600  pF  @  1000  Hz 

1600 

5500A  Console 

1  nF  @  1000  Hz 

1600 

5500A  Console 

2  nF  @  1000  Hz 

1200 

5500A  Console 

7  nF  @  1000  Hz 

1200 

5  500 A  Console 

10.9  nF  @  1000  Hz 

1000 

5500A  Console 

20  nF  @  1000  Hz 

1000 

5500A  Console 

70  nF  @  1000  Hz 

820 

5500A  Console 

200  nF  @  1000  Hz 

820 

5500A  Console 

300  nF  @  1000  Hz 

820 

5500A  Console 

700  nF  @  100  Hz 

820 

5  500 A  Console 

2  nF  @  100  Hz 

850 

5500A  Console 

3  nF  @  100  Hz 

850 

5500A  Console 

1  jxF  @  100  Hz 

850 

5500A  Console 

10.9  fj.F  @  100  Hz 

850 

5500A  Console 

20  [jlF  @  100  Hz 

850 

5  500 A  Console 

30  nF  @  100  Hz 

860 

5500A  Console 

70  fxF  @  100  Hz 

900 

5500A  Console 

200  ^F  @  100  Hz 

1500 

5500A  Console 

300  ^F  @  100  Hz 

1550 

5500A  Console 

330  ^F  @  50  Hz 

1700 

5500A  Console 

1 . 1  mF  @  50  Hz 

2400 

5500A  Console 

NVLAP  1999  DIRECTORY  -  Page  E62 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  Code:  20/E15 
Phase 

5500A  Console 


Best  Uncertainty  (±)  in  degrees'""11 

Range  Frequency  in  Hertz  Mode 

Phase  (degrees) 


60 

65 

400 

1  k 

5  k 

10  k 

0 

0.02 

0.06 

ACV/ACC 

0 

0.02 

0.06 

0.06 

0.06 

0.06 

ACV/ACV 

60 

0.02 

0.06 

0.06 

0.06 

0.06 

ACV/ACV 

90 

0.02 

0.06 

0.06 

0.06 

0.06 

ACV/ACV 

NVLAP  Code:  20/E15 
Phase 

At  Factory  Annex  -  Multiproduct  Calibrators  Similar  to  Fluke  5500A 


Range  in  Degrees 

0 

0 
60 
60 
90 
90 


Frequency  in  Hz 
60  to  65 
400  to  10  k 
60 

400  to  10  k 
60 

400  to  10  k 


Best  Uncertainty  (±)  in  Degrees"0"1 
0.025 
0.075 
0.025 
0.075 
0.025 
0.075 


TIME  AND  FREQUENCY 

NVLAP  Code:  20/F01 
Frequency 


Range  in  Hz 
119  to  120 
1000 
100000 


Best  Uncertainty  (±)  in  ppmno'el 
1 
1 
1 


Remarks 
5500A  Console 
5  500 A  Console 
5500A  Console 


NVLAP  1999  DIRECTORY  -  Page  E63 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  Code:  20/F01 
Frequency 

At  Factory  Annex  -  Multiproduct  Calibrators  Similar  to  Fluke  5500A 

Range  in  Hz  Best  Uncertainty  (±)  in  ppmnole  1 

119  5 

120  5 
1000  5 
100000  5 


Remarks 
5500A  Console 
5500A  Console 
5500A  Console 
5500A  Console 


THERMODYNAMICS 

NVLAP  Code:  20/T03 
Temperature 


Range  in  °C 

-40  to  -197 
-1  to  -40 
-1  to  1 
0.01 
1  to  150 

150  to  350 


Best  Uncertainty  (±)  in  mK""e  1 
11 

8 
5 

4.5 
10 
15 


Remarks 


NVLAP  Code:  20/T06 
Thermocouple  Temperature 


Range  in  °C  Best  Uncertainty  (±)  in  °C'el 

Simulated  TC  Temperature  with  UUT  Sourcing,  5500  Console  Measuring 
0  0.03 


100 


-100 


1000 


•1000 


10000 


•10000 


0.03 


0.03 


0.04 


0.04 


0.08 


0.08 


Remarks 


10  fiV/C  Linear  Mode,  Voltage 
Simulates  Temperature 

10  /xV/C  Linear  Mode,  Voltage 
Simulates  Temperature 

10  ^tV/C  Linear  Mode,  Voltage 
Simulates  Temperature 

10  /J.V/C  Linear  Mode,  Voltage 
Simulates  Temperature 

10  fiV/C  Linear  Mode,  Voltage 
Simulates  Temperature 

10  jxVIC  Linear  Mode,  Voltage 
Simulates  Temperature 

10  fiV/C  Linear  Mode,  Voltage 
Simulates  Temperature 


NVLAP  1999  DIRECTORY  -  Page  E64 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Simulated  TC  Temperature  with  UUT  Measurement,  5500A  Console  Sourcing 

0.05 


0 

10000 
-10000 
30000 
-30000 


0.12 
0.12 
0.24 
0.24 


10  /xV/C  Linear  Mode,  Voltage 
Simulates  Temperature 

10  [iV/C  Linear  Mode,  Voltage 
Simulates  Temperature 

10  fiVIC  Linear  Mode,  Voltage 
Simulates  Temperature 

10  /*V/C  Linear  Mode,  Voltage 
Simulates  Temperature 

10  fxWIC  Linear  Mode,  Voltage 
Simulates  Temperature 


Thermocouple  Temperature 
23 


0.18 


Type  K 


NVLAP  Code:  20/T08 
Simulated  Temperature 

At  Factory  Annex  -  Multiproduct  Calibrators  Similar  to  Fluke  5500A 


Range  in  °C 

0  to  +1000 
+  10000 
0 
23 

± 10000 
+  30000 


Function 

Source 

Source 

Measure 

Measure 

Measure 

Measure 


Best  Uncertainty  (+)in  °C""e  1 
0.1 
0.16 
0.1 
0.05 
0.2 
0.4 


1.  Represents  an  expanded  uncertainty  at  a  level  of  confidence  of  99%;  coverage  factor  k  is  determined  by 
the  test  statistics. 

2.  Approximate  value.  Actual  value  determined  by  the  test  statistics. 

3 .  E  =  Actual  Voltage 

4.  1000  V  Limit  is  8  kHz. 


NVLAP  1999  DIRECTORY  -  Page  E65 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  105017-0 

LOCKHEED  MARTIN  TECHNICAL  OPERATIONS 

1111  Lockheed  Way,  P.O.  Box  3504 
Bldg.  195A,  Org  48-70 
Sunnyvale,  CA  94089-3504 
Contact:  Dr.  Klaus  B.  Jaeger 
Phone:  408-756-0270    Fax:  408-742-4435 
E-Mail:  klaus.jaeger@lmco.com 

Accreditation  Valid  Through:  December  31,  1999 


DIMENSIONAL 


NVLAP  Code:  20/D03 
Gage  Blocks 

Range 

He-Ne  Laser 

633  nm 
NPL-Tesa  Interferometer 

0.01  to  12  in 


Best  Uncertainty  (±)n 


0.0014  ppm 


Remarks 


Comparison 


Interferometer 


(25.0  nm)2+(0.32  —  Z-(nm))2  nm 
mm 


Gage  Block  Sets 

5.0  to  12  in                1.8  to  4.0  ttin  Interferometer 

0.01  to  12  in              0.98  to  4.0  tiin  Interferometer 

0.3  to  100  mm            25  to  41  nm  Interferometer 

0.01  to  12  in              1.2  to  5.0  tiin  Comparator 

16  to  20  in                 6.6  to  8.2  tiin  Comparator 

0.3  to  100  mm            25.6  to  51.2  nm  Comparator 

ELECTROMAGNETIC  -  DC/LOW  FREQUENCY 

NVLAP  Code:  20/E01 
Thermal  Voltage  Converters 

Single-Range  Coaxial  Thermal  Voltage  Converters  (Best  uncertainty  (±)  in  fiV/V  or  iff6)"0'1 1 

Frequency  in  Hertz 


Range 

10 

20 

40 

100 

/  k 

20  k 

50  k 

100  k 

200  k     300  k 

500  k 

1  M 

1  V 

20 

16 

14 

10 

12 

12 

32 

48 

84 

84 

84 

3  V 

20 

16 

20 

10 

10 

10 

32 

48 

84 

84 

84 

6  V 

20 

16 

16 

10 

10 

10 

40 

48 

84 

84 

84 

10  V 

20 

16 

16 

10 

10 

10 

32 

48 

84 

84 

84 

NVLAP  1999  DIRECTORY  -  Page  E66 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NYLAP  LAB  CODE  -  continued 


Single-Range  Coaxial  Thermal  Voltage  Converters  (Best  uncertainty  (±)  in  n  V/V  or  IP6)' 


Frequency  in  Hertz 


Range 

10 

20 

40 

100 

1  k 

20  k 

50  k 

100  k 

200  k 

30  V 

24 

18 

16 

14 

10 

14 

32 

48 

84 

60  V 

24 

18 

16 

14 

10 

14 

32 

48 

84 

100  V 

24 

18 

16 

16 

16 

16 

38 

60 

86"°'e  4 

300  V 

150"°" 4 

40no'e  4 

4Q«o'<?  4 

16 

24 

16 

38 

60 

600  V 

l5Qnote  4 

40«o<«  * 

4Qio«  * 

20 

20 

20 

38 

60no,e  4 

1000  V 

I50no'e4 

50no,e  4 

50note  4 

46 

36 

32 

4Q"0'e  4 

60"°"  4 

Multi-Range  Coaxial  Thermal  Voltage  Converters  (Best  uncertainty  (±)  in  /iV/V  or  10'6)' 

Frequency  in  Hertz 


Range 

50 

1  k 

10  k 

20  k 

30  k 

50  k 

100  k 

200  k 

500  k 

1  M 

0.5  V 

36 

56 

52 

66 

126 

154 

1  V 

38 

44 

56 

72 

120 

142 

2  V 

38 

44 

56 

72 

120 

142 

3  V 

38 

44 

70 

82 

120 

142 

5  V 

38 

44 

70 

82 

120 

142 

10  V 

56 

60 

70 

82 

120 

142 

20  V 

56 

60 

70 

82 

122 

30  V 

56 

62 

70 

82 

134 

50  V 

78 

62 

90 

108 

198 

100  V 

78 

62 

92 

110 

200  V 

78 

84 

92 

126 

300  V 

82 

92 

94 

92 

150 

500  V 

82 

92 

96 

104 

1000  V 

88 

90 

92 

102 

NVLAP  1999  DHtECTORY  -  Page  E67 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  Code:  20/E05 
DC  Resistance 

Primary  Reference  Transfer  Level 
Range 
1.0  ohm 
10.0  k  ohm 

Primary  Reference  Level 

0.001  ohm 
0.01  ohm 
0.1  ohm 
1.0  ohm 
10.0  ohm 
100.0  ohm 
1.0  k  ohm 
10.0  k  ohm 
100.0  k  ohm 
1.0  M  ohm 


Working  Level 


0.001 
0.01 
0.1 
1.0 
10.0 
100.0 
1.0  k 
10.0  k 
100.0  k 
1.0  M 


Best  Uncertainty  (±)  in  ppmnote  1 

0.21 

0.25 

0.78 

0.78 

0.78 

0.26 

0.28 

0.34 

0.35 

0.33 

2.1 

3.2 

0.78 

0.78 

0.78 

0.29 

0.32 

0.42 

0.56 

0.37 

2.2 

3.6 


Remarks 

Direct  Comparison 
Substitution  Method 

Direct  Comparison 
Direct  Comparison 
Direct  Comparison 
Substitution  Method 
Direct  Comparison 
Direct  Comparison 
Direct  Comparison 
Substitution  Method 
Direct  Comparison 
Direct  Comparison 

Direct  Comparison 
Direct  Comparison 
Direct  Comparison 
Substitution  Method 
Substitution  Method 
Substitution  Method 
Substitution  Method 
Substitution  Method 
Direct  Comparison 
Substitution  Method 


NVLAP  1999  DIRECTORY  -  Page  E68 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


ELECTROMAGNETIC  -  DC/LOW  FREQUENCY 


NVLAP  Code:  20/E06 
DC  Voltage 


Reference 
Standards 


Range 
10.0  volts 

1.0  volt 
1.018  volts 


Best  Uncertainty  (±)  in  ppm"ole  1 
0.025 

0.13 
0.10 


Remarks 
AJJ 

AJJ 
AJJ 


Zeners 

10.0  volts 
1.0  volt 
1.018  volts 
Standard  Reference  (transvolt) 
1.018  volts 

NVLAP  Code:  20/E10 
LF  Capacitance 


0.218 
0.277 
0.276 


Direct  Comparison 
Direct  Comparison 
Direct  Comparison 

Direct  Comparison 


Range 

Best  Uncertainty  (±)no,el 

Remarks 

Capacitance  (Automatic  Bridge,  All  Connectors) 

1.0-1000  pF  @  1  kHz 

0.00048% 

Direct/Substitution  Measurement 

Capacitance  (GR874  Connector,  3  Terminal) 

O.lpF  @  1  kHz 

0.0085% 

Direct  Measurement 

l.OpF  @  1  kHz 

0.0079% 

Direct  Measurement 

10.0  pF  @  1  kHz 

0.0039% 

Substitution  Method 

100.0  pF  @  1  kHz 

0.0039% 

Substitution  Method 

1000.0  pF  @  1kHz 

0.00056% 

Direct  Measurement 

10000.0  pF  @  1  kHz 

0.0089% 

Direct  Measurement 

Capacitance  (BNC  Connector,  3  Terminal) 

1.0  pF  @  1  kHz 

0.00063% 

Direct  Measurement 

10.0  pF  @  1  kHz 

0.00034% 

Substitution  Method 

100.0  pF  @  1  kHz 

0.00026% 

Substitution  Method 

100.0  pF  @  1  kHz 

0.0098% 

Direct  Measurement 

300.0  pF  @  1  kHz 

0.0098% 

Direct  Measurement 

500.0  pF  @  1  kHz 

0.0098% 

Direct  Measurement 

1000.0  pF  @  1  kHz 

0.0098% 

Direct  Measurement 

NVLAP  1999  DIRECTORY  -  Page  E69 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Range  Best  Uncertainty  (±)nole  1 

Capacitance  (GR900  Connector,  2  Terminal) 


1.0  pF 
2.0  pF 
5.0  pF 


1  kHz 
1  kHz 
1  kHz 


0.39% 
0.20% 
0.079% 
0.040% 
0.013% 
0.0061% 
0.0061% 


10.0  pF  @  1  kHz 

100.0  pF  @  1  kHz 

1000.0  pF  @  1  kHz 

10000.0  pF  @  1  kHz 
Capacitance  (HP-BNC  Connector,  4  Terminal) 

1.0pF@lkHz  0.0079% 

10.0  pF@l  kHz  0.0059% 

100.0  pF  @  1  kHz  0.0059% 

1000.0  pF  @  1  kHz  0.0059% 
Capacitance  (Banana  and  Binding  Post,  2  or  3  Terminal) 

100.0  pF  @  1  kHz 

1.0  nF  @  1  kHz 

2.0  nF  @  1  kHz 

5.0  nF  @  1  kHz 

10.0  nF  @  1  kHz 

20.0  nF  @  1  kHz 

50.0  nF  @  1  kHz 

0.1  uF  @  1  kHz 

0.2  uF  @  1  kHz 

0.5  uF  @  1  kHz 

1.0  uF  @  1  kHz 

NVLAP  Code:  20/E13 
Magnetics 

Permanent  Magnets,  Transverse 


Range 

0.05  Tesla 
0.1  Tesla 
0.2  Tesla 
0.3  Tesla 
0.5  Tesla 
1.0  Tesla 


Best  Uncertainty  (±)"<"el 

0.10% 

0.58% 

0.14% 

0.24% 

0.46% 

0.08% 


Remarks 

Direct  Measurement 
Direct  Measurement 
Direct  Measurement 
Direct  Measurement 
Substitution  Method 
Direct  Measurement 
Direct  Measurement 

Direct  Measurement 
Direct  Measurement 
Direct  Measurement 
Direct  Measurement 


0.0049% 

Direct 

Measurement 

0.009% 

Direct 

Measurement 

0.0089% 

Direct 

Measurement 

0.0089% 

Direct 

Measurement 

0.0089% 

Direct 

Measurement 

0.0089% 

Direct 

Measurement 

0.0091% 

Direct 

Measurement 

0.0091% 

Direct 

Measurement 

0.011% 

Direct 

Measurement 

0.018% 

Direct 

Measurement 

0.022% 

Direct 

Measurement 

Method 

Direct  Transfer 
Direct  Transfer 
Direct  Transfer 
Direct  Transfer 
Direct  Transfer 
Direct  Transfer 


NVLAP  1999  DIRECTORY  -  Page  E70 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


TIME  AND  FREQUENCY 


NVLAP  Code:  20/F01 
Frequency  Dissemination 

Range 

Frequency  Accuracy:  Cesium  Beam 
1.0  MHz 
5.0  MHz 
10.0  MHz 

NVLAP  Code:  20/F03 
Oscillator  Characterization 


Offset  Frequency 


Best  Uncertainty  (±)" 

2.16  x  1013 
2.16  x  1013 
2.16  x  1013 


Remarks 

Primary  Reference/Working  Standard 
Primary  Reference/Working  Standard 
Primary  Reference/Working  Standard 


Range 

Best  Uncertainty  (±)no,el 

Remarks"0"3 

Carrier) 

System  Noise  Floor 

1  Hz 

2.48  dB 

-119.19  dBc/Hz 

2  Hz 

2.48  dB 

-130.81  dBc/Hz 

5  Hz 

2.48  dB 

-139.83  dBc/Hz 

10  Hz 

2.48  dB 

-144.79  dBc/Hz 

20  Hz 

2.48  dB 

-148.30  dBc/Hz 

50  Hz 

2.48  dB 

-153.00  dBc/Hz 

100  Hz 

2.48  dB 

-157.48  dBc/Hz 

200  Hz 

2.48  dB 

-160.82  dBc/Hz 

500  Hz 

2.48  dB 

-164.74  dBc/Hz 

1  noo  H7 

2.48  dB 

-168  36  dBc/Hz 

2000  Hz 

2.48  dB 

-169.98  dBc/Hz 

5000  Hz 

2.48  dB 

-172.40  dBc/Hz 

10000  Hz 

2.48  dB 

-173.12  dBc/Hz 

20000  Hz 

2.48  dB 

-173.90  dBc/Hz 

50000  Hz 

2.48  dB 

-173.88  dBc/Hz 

100000  Hz 

2.48  dB 

-174.18  dBc/Hz 

Carrier) 

1  Hz 

2.48  dB 

-113.67  dBc/Hz 

2  Hz 

2.48  dB 

-125.75  dBc/Hz 

5  Hz 

2.48  dB 

-136.63  dBc/Hz 

10  Hz 

2.48  dB 

-143.17  dBc/Hz 

20  Hz 

2.48  dB 

-148.10  dBc/Hz 

50  Hz 

2.48  dB 

-153.08  dBc/Hz 

NVLAP  1999  DIRECTORY  -  Page  E71 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Range 
100  Hz 
200  Hz 
500  Hz 
1000  Hz 
2000  Hz 
5000  Hz 
10000  Hz 
20000  Hz 
50000  Hz 
100000  Hz 

Amplitude  Noise  (5  MHz  Carrier) 

1  Hz  thru  1  MHz 

Amplitude  Noise  (10  MHz  Carrier) 

1  Hz  thru  1  MHz 

Amplitude  Noise  (10.6  GHz  Carrier) 

10  Hz  thru  1  MHz 


Best  Uncertainty  (±)no'e  1 

2.48  dB 

2.48  dB 

2.48  dB 

2.48  dB 

2.48  dB 

2.48  dB 

2.48  dB 

2.48  dB 

2.48  dB 

2.48  dB 

2.48  dB 

2.48  dB 

2.48  dB 


Remarks"0" 3 
-156.91  dBc/Hz 
-159.86  dBc.Hz 
-163.57  dBc/Hz 
-166.96  dBc/Hz 
-168.45  dBc/Hz 
-168.94  dBc/Hz 
-169.67  dBc/Hz 
-168.54  dBc/Hz 
-169.28  dBc/Hz 
-171.02  dBc/Hz 


MECHANICAL 


NVLAP  Code:  20/M11 
Acceleration 

Range 

10  Hz  @  2  g 
15  Hz  @  5  g 
30-50Hz  @10  g 
100  Hz  @  5  g 
100-2000  Hz  @  lOg 
2000  Hz  @  5  g 
2.5  -  10  kHz  @  lOg 


Best  Uncertainty  (±)note  1 

3.6% 

2.6% 

2.6% 

1.6% 

1.6% 

1.4% 

4.2% 


Remarks 

Double  Displacement  Back  to  Back  Cal 
Double  Displacement  Back  to  Back  Cal 
Double  Displacement  Back  to  Back  Cal 
Double  Displacement  Back  to  Back  Cal 
Double  Displacement  Back  to  Back  Cal 
Double  Displacement  Back  to  Back  Cal 
Double  Displacement  Back  to  Back  Cal 


NVLAP  1999  DIRECTORY  -  Page  E72 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


THERMODYNAMICS 

NVLAP  Code:  20/T07 

Resistance  Thermometry 

SPRT,  Fixed  Point,  83.8058  to  933.473  K 


ITS-90  Sub  Range 

Best  Uncertainty  (±)"0,e  5 

Required  Fixed  Points 

83.8058  to  273.16  K 

0.00052  K 

TP  Ar,  Hg  and  H20 

234.3156  to  302.9146  K 

0.00030  K 

TP  Hg,  H20  and  MP  Ga 

273.15  to  302.9146  K 

0.00062  K 

MP  Ga  and  TP  H20 

273.15  to  429.7485  K 

0.00044  K 

FP  In  and  TP  H20 

273.15  to  505.078  K 

0.0010  K 

FP  Sn,  In  and  TP  H20 

273.15  to  692.677  K 

0.0010  K 

FP  Zn,  Sn  and  TP  H20 

273.15  to  933.473  K 

0.0012  K 

FP  Al,  Zn,  Sn  and  TP  H20 

RTD  Devices  (Typically  PRT,  thermistor,  etc.) 

Range  Best  Uncertainty  (±)nole  1  Method 

77  to  553  K  0.0026  k  Comparison 

553  to  693  K  0.017  K  Comparison 


1.  Represents  an  expanded  uncertainty  using  a  coverage  factor,  k=2 

2.  Approximate  value.  Actual  value  determined  by  the  test  statistics. 

3.  External  customer  oscillator  AM  or  PM  noise  must  be  >20  dB  above  system  noise  floor.  Oscillators 
with  lower  noise  levels  are  individually  analyzed  with  correspondingly  higher  uncertainties. 

4.  Manual  measurements  to  be  performed. 

5.  Actual  SPRT  uncertainty  is  a  smooth  curve  propagated  from  fixed  point  uncertainties  and  may  be  lower 
than  shown  here,  as  temperatures  approach  the  triple  point  of  water,  (reference  NISTIR  5319) 


NVLAP  1999  DERECTORY  -  Page  E73 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  105018-0 

CDRH  X-RAY  CALIBRATION  LABORATORY 

Health  X-Ray  Calibration  Laboratory 
12720  Twinbrook  Parkway  HFZ-143 
Rockville,  MD  20857 
Contact:  Mr.  Frank  Cerra 
Phone:  301-443-2536  x23    Fax:  301-443-9101 
E-Mail:  fxc@cdrh.fda.gov 
URL:  http://www.fda.gov/cdrh 

Accreditation  Valid  Through:  December  31,  1999 

This  facility  has  demonstrated  compliance  with  the  NVLAP  Criteria  for  Calibration  Laboratories  under  the  field  of 
Ionizing  Radiation  for  the  following: 

Procedures/ Instruments  Radiation  Types 

Calibration  of  Survey  Instruments  X-ray  Beam  Codes  M30,  M50,  L80,  L100,  and  M100  over  the 

Exposure  Rate  Range  2  mR/s  to  100  mR/s,  and  the  H50  Beam 
Code  over  the  range  0.5  mR/h  to  4  mR/s,  with  total  uncertainty  in 
the  reference  field  value  of  +  5  percent. 


Calibration  of  Instruments  for  Diagnostic  Level        X-ray  Beam  Codes  M20,  M30,  M50,  L80,  L100,  and  M100  over 

the  Exposure  Rate  Range  2  mR/s  to  100  mR/s,  with  total 
uncertainty  in  the  reference  field  value  of  +  3  percent. 


Calibration  of  Reference-Class  Instruments  X-ray  Beam  Codes  M20,  M30,  M50,  L80,  L100,  and  M100  over 

the  Exposure  Rate  Range  2  mR/s  to  100  mR/s,  with  total 
uncertainty  in  the  reference  field  value  of  ±  3  percent. 


NVLAP  1999  DIRECTORY  -  Page  E74 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  105020-0 

PACIFIC  NORTHWEST  NATIONAL  LABORATORY 

Battelle  Boulevard 
P.O.  Box  999 
Richland,  WA  99352 
Contact:  Mr.  R.  Kim  Piper 
Phone:  509-376-6187    Fax:  509-376-1992 
E-Mail:  kim.piper@pnl.gov 
URL :  http : //www.pnl . gov/health/health_prot/cra_page . html 

Accreditation  Valid  Through:  December  31,  1999 

This  facility  has  demonstrated  compliance  with  the  NVLAP  Criteria  for  Calibration  Laboratories  under  the  field  of 
Ionizing  Radiation  for  the  following: 

Calibration  Category      Radiation  Type  or  Nominal  Intensity  Range"01" 3    Uncertainty  of  Reference  Field 

Beam  Code  (±)no,e  l-1 

CALIBRATION  OF  SURVEY  INSTRUMENTS 

Gamma                      241Am  0.125  R/h  5.2% 

137Cs  0.1  to  250  R/h  1.5% 

^Co  4  to  60,000  R/h  1.5% 


X-ray  M30  3  to  500  R/h  1.5% 

M50  4  to  600  R/h  1.5% 

M60  3  to  450  R/h  1.5% 

M100  3  to  500  R/h  1.5% 

M150  4  to  550  R/h  1.5% 

M200  4  to  650  R/h  1.5% 

S60  1  to  175  R/h  1.5% 

S75  5  to  700  R/h  1.5% 

H40  0.02  to  4  R/h  1.5% 

H50  0.05  to  10  R/h  1.5% 

H100  0.02  to  3  R/h  1.5% 

H150  1  to  15  R/h  1.5% 

H200  0.9  to  9  R/h  1.5% 

H250  0.9  to  9  R/h  1.5% 

H300  0.6  to  3  R/h  1.5% 

Beta  204T1  0.9  rad/h  4.4% 

^Sr/^Y  0.4  to  19  rad/h  4.0% 


NVLAP  1999  DIRECTORY  -  Page  E75 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Neutron  252Cf  Bare  0.014  to  4.8  rem/h  7.6% 

252Cf  Moderated  0.004  to  1.1  rem/h  21.4% 

Calibration  Category      Radiation  Type  or  Nominal  Range"01" 4  Uncertainty  of  Delivered 

Beam  Code  Quantity  (±)no,e  1,2 


IRRADIATION  OF  PERSONNEL  DOSIMETERS 

Gamma 

241Am 

>  0.002  R 

5.4% 

137Cs 

>  0.020  R 

3.6% 

^Co 

>  0.025  R 

3.6% 

X-ray 

M30 

>  0.025  R 

3.6% 

M50 

>  0.035  R 

3.6% 

M60 

>  0.025  R 

3.6% 

M100 

>  0.025  R 

3.6% 

M150 

>  0.035  R 

3.6% 

3.6% 

S60 

>  0.010  R 

3.6% 

S75 

>  0.040  R 

3.6% 

3.6% 

H50 

>  0.0005  R 

3.6% 

H100 

>  0.0002  R 

3.6% 

H150 

>  0.008  R 

3  6% 

H200 

>  0.008  R 

3.6% 

H250 

>  0.008  R 

3.6% 

H300 

>  0.005  R 

3.6% 

Neutron 

>  0.015  rad 

11.8% 

90Sr/90Y 

>  0.007  rad 

5.4% 

Beta 

252Cf  Bare 

>  0.001  rem 

8.0% 

252Cf  Moderated 

>  0.002  rem 

22.4% 

NVLAP  1999  DHtECTORY  -  Page  E76  (See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


CALIBRATION  OF  REFERENCE-CLASS  INSTRUMENTS 

Calibration  Category      Radiation  Type  or  Nominal  Intensity  Range"0" 3    Uncertainty  of  Reference  Field 


Beam  Code  (±)nou  1,2 

Gamma  137Cs  0.1  to  250  R/h  1.5% 

^Co  4  to  60,000  R/h  1.5% 

X-ray  M30  3  to  500  R/h  1.5% 

M50  4  to  600  R/h  1.5% 

M60  3  to  450  R/h  1.5% 

M100  3  to  500  R/h  1.5% 

M150  4  to  550  R/h  1.5% 

M200  4  to  650  R/h  1.5% 

S60  1  to  175  R/h  1.5% 

S75  5  to  700  R/h  1.5% 

H40  0.02  to  4  R/h  1.5% 

H50  0.05  to  10  R/h  1.5% 

H100  0.02  to  3  R/h  1.5% 

H150  1  to  15  R/h  1.5% 

H200  0.9  to  9  R/h  1.5% 

H250  0.9  to  9  R/h  1.5% 

H300  0.6  to  3  R/h  1.5% 


1.  Values  listed  at  the  95%  confidence  level. 

2.  Uncertainties  are  valid  for  nominal  intensity  range  shown  at  right. 

3.  For  calibration  outside  of  the  nominal  intensity  range  shown,  uncertainties  would  be  determined 
commensurate  with  the  parameters  of  the  reference  field  calibration. 


NVLAP  1999  DDtECTORY  -  Page  E77 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  105023-0 

INSTRON  FORCE  CALIBRATION  LABORATORY 

100  Royall  Street 
Canton,  MA  02021 
Contact:  Dr.  Anatoly  Perlov 
Phone:  781-575-5479    Fax:  781-575-5767 
E-Mail:  Anatoly_Perlov@instron.com 
URL:  http://www.instron.com 

Accreditation  Valid  Through:  September  30,  1999 

NVLAP  Code/  Range  Best  Uncertainty  (±)"°<es  W  Remarks 

Parameters 

MECHANICAL 

20/M06 

Force 

Applied  Force  in 
Pounds 

0.1  to  130000  0.005% 
130000  to  240000  0.005% 


Primary  Standard 
Secondary  Standard 


1.  Represents  an  expanded  uncertainty  using  a  coverage  factor,  k  =  2 

2.  Uncertainty  of  the  voltage  ratio  is  <0.1  microvolt  per  volt 

3.  Uncertainty  of  the  measured  value  is  determined  by  the  statistics  of  the  test  and  the  artifact  tested  but 
are  typically  better  than  +0.05%  for  class  AA  instruments,  ±0.25%  for  class  A  instruments  and 
±0.1%  for  class  Al  instruments. 


NVLAP  1999  DIRECTORY  -  Page  E78 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  200029-0 

GE  INDUSTRIAL  SYSTEMS,  RENEWAL  SERVICES  -  TEMS 

92  Otis  Street 
Rome,  NY  13441 
Contact:  Mr.  Alan  L.  Brust 
Phone:  315-334-7605    Fax:  315-334-7660 
E-Mail:  alan.brust@indsys.ge.com 

Accreditation  Valid  Through:  December  31,  1999 

ELECTROMAGNETICS/DC-LOW  FREQUENCY 

NVLAP  Code:  20/E05 
DC  Resistance 

Value  in  ohms  Best  Uncertainty  in  ppm  (±)note  1  Remarks 


0.1 

1.0 

1 

1.0 

10 

1.0 

100 

1.0 

1  k 

1.5 

10  k 

1.5 

100  k 

4.0 

1  M 

4.6 

10  M 

6.2 

100  M 

13.4 

NVLAP  Code:  20/E06 
DC  Voltage 


Range  in  Volts  Best  Uncertainty  in  ppm  (±ful  Remarks 

0.1  3  Zener  Reference  Diodes,  Standard 

Cells,  High  Level  MMs  and 
Calibrators 

1.0  1.5  Zener  Reference  Diodes,  Standard 

Cells,  High  Level  MMs  and 
Calibrators 

10.0  1.2  Zener  Reference  Diodes,  Standard 

Cells,  High  Level  MMs  and 
Calibrators 

100.0  1.5  Zener  Reference  Diodes,  Standard 

Cells,  High  Level  MMs  and 
Calibrators 

1000.0  2.0  Zener  Reference  Diodes,  Standard 

Cells,  High  Level  MMs  and 
Calibrators 


NVLAP  1999  DD3ECTORY  -  Page  E79 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


THERMODYNAMICS 

NVLAP  Code:  20/T05 
Pressure 


Range  Uncertainty  (±)  of  reading"0" 1  Remarks 

0.2  to  1000  psia  36  ppm  Inert  Gas 

0.2  to  1000  psi  36  ppm  Inert  Gas 

15  to  10000  psi  0.02%  Inert  Gas 

15  to  15000  psi  0.02%  Fluid 


1.     Represents  an  expanded  uncertainty  using  a  coverage  factor,  k  =  2 


NVLAP  1999  DIRECTORY  -  Page  E80 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  200038-0 


WEBBER  GAGE  DIVISION  /  L.S.  STARRETT  CO. 

24500  Detroit  Road 
Cleveland,  OH  44145 
Contact:  Mr.  David  Friedel 
Phone:  440-835-0001    Fax:  440-892-9555 


Accreditation  Valid  Through:  December  31,  1999 


DIMENSIONAL 

NVLAP  Code:  20/D03 
Gage  Blocks 

Range 

Standard  Size  Gage  Blocks 
thru  1.0  in 
thru  25  mm 

>  1.0  thru  4.0  in 

>  25  thru  100mm 

>  4.0  thru  20.0  in 

>  100  thru  500.0  mm 
thru  4.0  in 

thru  100  mm 
>4.0  thru  20.0  in 

>  100  thru  500  mm 
Non  Standard  Size  Gage  Blocks 

to  1.0  in 

to  25  mm 

>1.0  thru  4.6  in 

>  25  thru  117mm 
>4.6  thru  20.0  in 

>  117  thru  500  mm 


Best  Uncertainty  (±f«*1** 


1.3  /tin 
0.035  ixm 
(0.8  +  0.5L)  /an 
(0.02  +  0.5L)  /tm 
(3.5  +  0.25L)  fiin 
(0.09  +  0.25L)  fim 
(1.4  +  0.6L)  fi'm 
(0.035  +  0.6L)  /an' 
(6.0  +  0.3L)  fim 
(0.15  +  0.3L)  Mm 


.note  4 


note  5 


2.2  fllli 

0.055  urn 
(1.6  +  0.6L)  /tin 
(0.04  +  0.6L)  /tm 
(6.0  +  0.35L)  /tin 
(0.15  +  0.35L)  /tm 


Remarks 

Master  Grade  Calibration 
Master  Grade  Calibration 
Master  Grade  Calibration 
Master  Grade  Calibration 
Master  Grade  Calibration 
Master  Grade  Calibration 
Commercial  Grade  Calibration 
Commercial  Grade  Calibration 
Commercial  Grade  Calibration 
Commercial  Grade  Calibration 


Master  Grade 
Master  Grade 
Master  Grade 
Master  Grade 
Master  Grade 
Master  Grade 


Calibration 
Calibration 
Calibration 
Calibration 
Calibration 
Calibration 


1.  Represents  an  expanded  uncertainty  using  a  coverage  factor,  k=2. 

2.  Approximate  value.  Actual  value  determined  by  the  test  statistics. 

3.  L  is  in  inches  or  meters  as  appropriate. 

4.  Uncertainty  not  less  than  2.0  /tin. 

5.  Uncertainty  not  less  than  0.05  /tm. 


NVLAP  1999  DIRECTORY  -  Page  E81 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  200106-0 


DENVER  INSTRUMENT  CO.  WEIGHT  LAB 

6542  Fig  Street 
Arvada,  CO  80004-1042 
Contact:  Mr.  Darryl  Sampson 
Phone:  303-431-7255    Fax:  303-423-4831 


Accreditation  Valid  Through:  December  31,  1999 

MECHANICAL 
NVLAP  Code:  20/M08 
Mass 


Range 

Best  Uncertainty  (±) 

5  kg 

3.8  mg 

4  kg 

2.4  mg 

3  kg 

2.4  mg 

2  kg 

0.37  mg 

1  kg 

0.33  mg 

500  g 

0.080  mg 

400  g 

0.075  mg 

300  g 

0.071  mg 

200  g 

0.056  mg 

160  g 

0.055  mg 

150  g 

0.055  mg 

100  g 

0.029  mg 

50  g 

0.0215  mg 

40  g 

0.0216  mg 

30  g 

0.0216  mg 

20  g 

0.0208  mg 

10  g 

0.0127  mg 

5g 

0.0111  mg 

3g 

0.0112  mg 

2g 

0.0108  mg 

lg 

0.0108  mg 

500  mg 

0.0030  mg 

300  mg 

0.0031  mg 

200  mg 

0.0030  mg 

100  mg 

0.0029  mg 

Remarks 


NVLAP  1999  DIRECTORY  -  Page  E82 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Range  Best  Uncertainty  (±)no,e  1  Remarks 

50  mg  0.0028  mg 

30  mg  0.0029  mg 

20  mg  0.0028  mg 

10  mg  0.0026  mg 

5  mg  0.0026  mg 

3  mg  0.0027  mg 

2  mg  0.0026  mg 

1  mg  0.0026  mg 


1.     Represents  an  expanded  uncertainty  using  a  coverage  factor,  k=2. 


NVLAP  1999  DDtECTORY  -  Page  E83 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  200108-0 

ALLIEDSIGNAL  FM&T  METROLOGY 

2000  East  95th  Street 
P.O.  Box  419159 
Kansas  City,  MO  64141-6159 
Contact:  Mr.  Roger  N.  Burton 
Phone:  816-997-5431    Fax:  816-997-3856 
E-Mail:  rburton@kcp.com 

Accreditation  Valid  Through:  December  31,  1999 

DIMENSIONAL 

NVLAP  Code:  20/D01 
Angle  Blocks 

Range  Best  Uncertainty  (±)"°'e  1  Remarks 

up  to  45  °  1.1  arc  seconds  Comparison  Method 

Autocollimators 

0  to  600  arc  seconds  (0.3  arc  seconds  +  0.25%  of  angle)  Small  Angle  Generator 


Index  Table/Polygons 

0  to  360  0  0.6  arc  seconds  3  Stack  Method 

(in  10  0  or  30  ° 

increments) 


Optical  Comparators 

Length  up  to  12  in 
Angle  0  to  360  ° 


(0.0002  +  30L  )  inno,c2 
0.1  0 


Magnifications  Standard 
Angle  Blocks 


NVLAP  Code:  20/D03 
Gage  Blocks 

Range 


up  to  4  in 

>  4  in  to  20  in 
up  to  100  mm 

>  100  mm  to  500  mm 


Best  Uncertainty  (±)note  4 
(3.2  +  .88L)  /an"0"2 
(5.8  +  .53L)  ninno'e2 
(0.081  +  .88L)  ixm"0"3 
(0.161  +  .41L)  nmno,e3 


Remarks 

Comparison 

Comparison 

Comparison 

Comparison 


NVLAP  Code:  20/D04 
Laser  Frequency /Wavelength 

Laser  Type 

HeNe 


Best  Uncertainty  (±) 
0.05  ppm 


Remarks 
Comparison 


NVLAP  1999  DIRECTORY  -  Page  E84 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NYLAP  LAB  CODE  -  continued 


NVLAP  Code:  20/D05 
Length 

Stage  Micrometers  (Chrome  on  Glass) 

Range  Best  Uncertainty  (±)'""e  1  Remarks 

0  to  2  in  18  /tin  Laser  Interferometer  with  Laser  Edge 

Detection 


Undirectional  Step  Gages 
0  to  24  in 


(20  /tin  +  1.8L)" 


CMM  with  Bi-swing  Probe 


Inspection  Masters 
0  to  2  in 

>2  to  12  in 


Magnification  Scales 

up  to  24  in 
Micrometer  Masters 

0  to  3  in 
Precision  Micrometer  Heads 

0  to  2  in 

(0  to  50  mm) 
1-D  Ball  Plates 

up  to  48  in 

Squares 

up  to  24  in  by  36  in 
Straight  Edges 

up  to  48  in 


Length  18  /xin 
Length  32  /tin 


0.0003  in 
60  /tin 
35  /tin 

(30  /tin  +  2L) 
30  /tin 
5  /tin 


note  2 


Laser  Interferometer  with  Laser  Edge 
Detection 

Laser  Interferometer  with  Laser  Edge 
Detection 


Perpendicularity  8  ppm  CMM  with  Video  Probe 


CMM  with  Video  Probe 


Single  -  Axis  Measuring  Machine 


Laser  Interferometer 


CMM  Single  -  Axis  Method 


CMM,  Self  Closing  Method 


CMM,  Reversal  Method 


Dial  Calipers 

<12  in 


0.002  in 


Gage  Blocks 


NVLAP  1999  DDtECTORY  -  Page  E85 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  Code:  20/D07 
Thread  Measuring  Wires 


Range  Best  Uncertainty  (±)no,e  1  Remarks 

All  29  °  and  60  0  Wires  8.0  /tin  Direct  Measurement 


NVLAP  Code:  20/D08 
Optical  Reference  Planes 
Optical  Flats,  Mirrors 

Range 

0  to  12  in 

0  to  12  in 

0  to  12  in 

NVLAP  Code:  20/D09 
Roundness 

Range 

up  to  18  in  Diameter 

NVLAP  Code:  20/D11 
Spherical  Diameter 
Master  Balls 

Range 

1/16  to  1.0  in 
(  1  to  25  mm) 

Calibration  Spheres 

to  1  in  (25  mm) 

OD  Micrometers 

up  to  3  in 


Best  Uncertainty  (+)' 
1.2  /tin 
2.0  /tin 
4.0  /tin 


Best  Uncertainty  (±)' 
3  /tin 


Best  Uncertainty  (±)' 
9  /tin 


1 1  /tin  Diameter 
5  /tin  Sphericity 

(0.0002  +  L/50000)  in' 


Remarks 
3  Flat  Method 
Interferometer  Method 
Comparison  to  Master 


Remarks 

Roundness  Machine 


Remarks 

Comparison  to  Master 


Comparison  to  Master 
Roundness 

Micrometer  Master 


NVLAP  Code:  20/D12 
Surface  Plates 

Range  Best  Uncertainty  (±)no,e  1  Remarks 

Up  to  8  ft  Diagonal  (30  /tin  +  2  /tin/ft2)  Moody  and  Least 

Squares  Method  with 
Autocollimator 


NVLAP  1999  DIRECTORY  -  Page  E86 


(See  4How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  Code:  20/D14 
Plug  Gages 

Range  Best  Uncertainty  (±)'""e  1  Remarks 

0  to  1  in  6.5  /xin  Comparison  to  Master 

Threaded  Plug  Gages  -  Pitch  and  Major  Diameter  per  ANSI  B1.2,  ANSI  B1.16M  or  ANSI  B1.5 

up  to  10  in  P. D.  0.0001  in  3  -  Wire  P.D.  Measurement 

M.D.  0.000035  in 


Adj.  -  Thread  Ring  Gages  -  Functional  Threads  per  ANSI/ASME  B1.2  (UN  or  UNR  Thread  Form),  ANSI/ASME 
B1.15  (UNJ  Threads) 


up  to  10  in 


P.D.  0.0002  in 
M.D.  0.0001  in 


Set  to  'W  Thread  Set  Master 


Thread  Set  Plugs  -  Pitch  and  Major  Diameter  per  ANSI  B1.2,  ANSI  B1.16M  or  ANSI  B1.5 

up  to  10  in  P.D.  0.000035  in  3  -  Wire  P.D.  Measurement 

M.D.  0.000020  in 


NVLAP  Code:  20/D15 
2-D  Ball  Plates 


Range 

36  in  x  36  in 


Best  Uncertainty  (±)no,eI 
(30  pin  +  2.5L)no'e2 


Remarks 

CMM  Single  -  Axial  Method 


NVLAP  Code:  20/D16 
Coordinate  Measuring  Machines 

Range 

To  120  x  120  x  120  in 


Best  Uncertainty  (±)no,el 
Axial  (10  +  1.5L)  pin 
Planar  (35  +  8.5L)  pin 


Remarks 

Parametrical  Calibration 


To  24  in  Volumetric 
Diagonals 


Axial  (35  +  4L)  pin 
Planar  (45  +  4L)  pin 
Spatial  (50  +  5L)  /xin 


Step  Gage 
Step  Gage 
Step  Gage 


To  56"  Volumetric 
Diagonals 


Axial  (60  +  3L)  /xin 
Spatial  (70  +  3L)  pin 


1-D  Ball  Plates 
1-D  Ball  Plates 


To  36"  Volumetric 


Axial  (50  +  5L)  /tin 


2-D  Ball  Plates 


NVLAP  1999  DD2ECTORY  -  Page  E87 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Range 

Diagonals 


Best  Uncertainty  (±)no,el 
Planar  (50  +  7L)  ^in 
Spatial  (50  +  9L)  fi'm 


Remarks 

2-D  Ball  Plates 


MECHANICAL 

NVLAP  Code:  20/M06 
Force 


Range 

5  thru  2400  lbf 
>2400  thru  100000  lbf 
>  100000  thru  300000  lbf 


Best  Uncertainty  (±)  in  %"0,e  1 

0.01 

0.015 

0.035 


Remarks 

of  Applied  Force 

of  Range 

of  Range 


NVLAP  Code:  20/M08 
Mass 


Range 

Best  Uncertainty  (±)  in  mg"0" 1 

Method 

5  kg 

19.70 

Direct-Reading  Weighing 

3  kg 

15.12 

Direct-Reading  Weighing 

2  kg 

12.08 

Direct-Reading  Weighing 

1  kg 

3.832 

Direct-Reading  Weighing 

500  g 

2.168 

Direct-Reading  Weighing 

300  g 

1.410 

Direct-Reading  Weighing 

200  g 

1.040 

Direct-Reading  Weighing 

100  g 

0.598 

Direct-Reading  Weighing 

50  g 

0.4480 

Direct-Reading  Weighing 

30  g 

0.4010 

Direct-Reading  Weighing 

20  g 

0.1528 

Direct-Reading  Weighing 

10  g 

0.1002 

Direct-Reading  Weighing 

5g 

0.0780 

Direct-Reading  Weighing 

3g 

0.0423 

Direct-Reading  Weighing 

2g 

0.0266 

Direct-Reading  Weighing 

1  g 

0.0296 

Direct-Reading  Weighing 

500  mg 

0.0272 

Direct-Reading  Weighing 

300  mg 

0.0267 

Direct-Reading  Weighing 

200  mg 

0.0265 

Direct-Reading  Weighing 

100  mg 

0.0264 

Direct-Reading  Weighing 

50  mg 

0.0264 

Direct-Reading  Weighing 

NVLAP  1999  DHtECTORY  -  Page  E88 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Range 

Best  Uncertainty  (±)  in  mg"0"1 

Method 

30  mg 

0.0264 

Direct-Reading  Weighing 

20  mg 

0.0045 

Single  Substitution  Comparison  to 
Reference  Weights 

10  mg 

0.0035 

Single  Substitution  Comparison  to 
Reference  Weights 

5  mg 

0.0034 

Single  Substitution  Comparison  to 
Reference  Weights 

3  mg 

0.0036 

Single  Substitution  Comparison  to 
Reference  Weights 

2  mg 

0.0034 

Single  Substitution  Comparison  to 
Reference  Weights 

1  mg 

0.0034 

Single  Substitution  Comparison  to 
Reference  Weights 

10  lb 

19.09 

Direct-Reading  Weighing 

8  lb 

15.90 

Direct-Reading  Weighing 

5  lb 

12.43 

Direct-Reading  Weighing 

4  lb 

10.80 

Direct-Reading  Weighing 

3  lb 

10.11 

Direct-Reading  Weighing 

2  lb 

3.723 

Direct-Reading  Weighing 

1  lb 

1.899 

Direct-Reading  Weighing 

0.5  lb 

1.150 

Direct-Reading  Weighing 

0.3  lb 

0.821 

Direct-Reading  Weighing 

0.2  lb 

0.575 

Direct-Reading  Weighing 

0.1  lb 

0.460 

Direct-Reading  Weighing 

0  05  lb 

0.417 

Direct-Reading  Weighing 

0  03  lb 

0.1277 

Direct-Reading  Weighing 

0.02  lb 

0.1064 

Direct-Reading  Weighing 

0.01  lb 

0.0998 

Direct-Reading  Weighing 

0  005  lb 

0.0518 

Direct-Reading  Weighing 

0  003  lb 

0.0458 

Direct-Reading  Weighing 

0  00?  lb 

\J.\J\JJ~  1U 

0.0290 

Direct-Reading  Weighing 

0  001  lh 
U.UU1  ID 

0  0356 

Direct-Reading  Weighing 

10  oz 

1.253 

Direct-Reading  Weighing 

8  oz 

1.150 

Direct-Reading  Weighing 

6  oz 

0.868 

Direct-Reading  Weighing 

5  oz 

0.865 

Direct-Reading  Weighing 

NVLAP  1999  DIRECTORY  -  Page  E89 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Range 

4  oz 

3  oz 

2  oz 

1  oz 

1/2  oz 

1/4  oz 

1/8  oz 

1/16  oz 

1/32  oz 

1/64  oz 

NVLAP  Code:  20/M11 
Vibration/ Acceleration 


Best  Uncertainty  (±) 

0.815 

0.551 

0.4850 

0.4250 

0.1373 

0.0985 

0.0968 

0.0482 

0.0370 

0.0356 


in  mg"0 


Range 

0.3  g  @  10  thru  40  Hz 

1  g  @  10  thru  100  Hz 

2  g  @  10  thru  100  Hz 
5  g  @  100  Hz 

10  g  @  30  thru  <  100  Hz 
10  g  @  100  thru  2000  Hz 
10  g  @  >  2000  thru  10000  Hz 


Method 

Direct-Reading 

Direct-Reading 

Direct-Reading 

Direct-Reading 

Direct-Reading 

Direct-Reading 

Direct-Reading 

Direct-Reading 

Direct-Reading 

Direct-Reading 


Weighing 
Weighing 
Weighing 
Weighing 
Weighing 
Weighing 
Weighing 
Weighing 
Weighing 
Weighing 


Best  Uncertainty  (±)  in  %note  1 

2.5 

2.5 

2.5 

2.5 

2.5 

1.8 

2.5 


Shock 


10  thru  10000  g  @  10  thru  10000  Hz 


3.5 


1.  Represents  an  expanded  uncertainty  using  a  coverage  factor,  k=2. 

2.  L  is  in  inches. 

3.  L  is  in  meters 

4.  Best  uncertainty  is  for  steel  blades. 


NVLAP  1999  DIRECTORY  -  Page  E90 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  200115-0 

LOCKHEED  MARTIN  IDAHO  TECH.  CO.,  STANDARDS  AND  CALIBRATION  LAB. 

P.O.  Box  1625 
Idaho  Falls,  ID  83415-4137 
Contact:  Mr.  Harry  J.  Moody 
Phone:  208-526-2656    Fax:  208-526-5462 
E-Mail:  moodhj@inel.gov 

Accreditation  Valid  Through:  December  31,  1999 


DIMENSIONAL 

NVLAP  Code:  20/D03 
Gage  Blocks 


Range 

Best  Uncertainty  (±) 

0-4" 

3.4  -  4.5  ftin 

5-8" 

4.5  -  5.9  iiin 

10-12" 

6.9  -  7.8  /tin 

16" 

9.8  /xin 

20" 

11.8  fim 

ELECTROMAGNETICS  -DC/LOW  FREQUENCY 


NVLAP  Code:  20/E05 
Resistance 

Range 

0.1  ohm 

1.0  ohm 

10.0  ohm 

100  ohm 

IK  ohm 

10K  ohm 

100K  ohm 

1M  ohm 


Best  Uncertainty  (±)no,e  1 

0.35  ppm 

0.3  ppm 

0.35  ppm 

0.5  ppm 

0.6  ppm 

0.5  ppm 

1.0  ppm 

5.0  ppm 


NVLAP  Code:  20/E06 
DC  Voltage 


Range 

10  volt  Zener  Reference 


Best  Uncertainty  (±)no,e  1 
0.3  ppm 


NVLAP  1999  DHtECTORY  -  Page  E91 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


TIME  AND  FREQUENCY 


NVLAP  Code:  20/F01 
Frequency  Dissemination 


Range 

0.1  MHz,  1  MHz,  5  MHz,  10  MHz 


Best  Uncertainty  (±)n°'e  1 
1  x  10  n/24  hours 


Remarks 

NIST  FMS  System 


NVLAP  Code:  20/F03 

Oscillator  Characterization  (Electronic  Counters) 
Range 

0.1  MHz,  1  MHz,  5  MHz,  10  MHz 


Best  Uncertainty  (±)notel 
5  x  10-10/24  hours 


Remarks 

NIST  FMS  System 


1.     Represents  an  expanded  uncertainty  using  a  coverage  factor,  k=2. 


NVLAP  1999  DffiECTORY  -  Page  E92 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  200123-0 

LIBERTY  LABS,  INC. 

1346  Yellow  wood  Road 

P.O.  Box  230 
Kimballton,  IA  51543 
Contact:  Mr.  Michael  W.  Howard 
Phone:  712-773-2199   Fax:  712-773-2299 
E-Mail:  mhoward@netins.net 

Accreditation  Valid  Through:  December  31,  1999 

ELECTROMAGNETIC  -  RF  MICROWAVE 

NVLAP  Code:  20/R08 
Microwave  Antenna  Parameters 

Range  Best  Uncertainty  in  dB  (±)no,el  Remarks 

Early  Designed  Biconical  Antennas  (such  as  the  EMCO  3104) 

30-60  MHz  1.7 

60-300  MHz  1.0 

New  Designed  Biconical  Antennas 
30-90  MHz 
90-300  MHz 

Log-Periodic  Antennas  (such  as  the  EMCO  3146) 
200-1000  MHz  1.0 
200-1000  MHz  1.1 
200-1000  MHz  1.0  to  2.2 

BiLog  Antennas  (such  as  the  Chase  CBL6111) 
20-1000  MHz  0.9 

Dipole  Antennas  (such  as  the  EMCO  3121) 
30-1000  MHz  0.6 

DRWG  Horn  Antennas  (such  as  the  EMCO  3115) 
1-18  GHz  1.1 
1-18  GHz  1.2 


(such  as  the  EMCO  3110) 
1.2 
0.9 


Vertical 
Horizontal 
Fixed  Heights 


3  Ant.  Method,  OATS 
Standard  Field,  OATS 


NVLAP  1999  DntECTORY  -  Page  E93 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Range 

Horn  Antennas  (above  18  GHz) 
18-40  GHz 


Best  Uncertainty  in  dB  (±)n 


1.2 


Remarks 


Standard  Field,  Anechoic 


LISN's 


10  kHz  to  100  MHz  0.4 
10  kHz  to  100  MHz  0.4 


Insertion  Loss 
Impedance 


Current  Probes/Injection  Probes 
5  Hz  -  500  MHz 


0.3 


Insertion  Loss 


Absorbing  Clamps 

30  to  1000  MHz 


2.3 


CDN'S  &  150-50  Ohm  Adapters 

10  kHz  to  230  MHz  0.4 

Isotropic  Probes 

10  kHz-1  GHz  2.4 

100  MHz  -  18  GHz  2.4 

10  kHz -1  GHz  1.3 

18-40  GHz  1.9 


Impedance  &  Insertion  Loss 

GTEM,  Boonton  MV 
GTEM,  PWR  Sensors 
Stripline 
Standard  Field 


RF  Pre-amps  &  Amps 

10  kHz  to  18  GHz 


0.4 


GAIN  Cal 


Loop  Antennas 

1kHz  -  30  MHz 
20  Hz  -  1  kHz 


1.1 
1.1 


Vacuo  Junction 
Series  Resistor 


Rod  Antennas 

100  Hz  to  30  MHz  0.5 

100  Hz  to  10  kHz  1.0 

10  kHz  to  30  MHz  0.9 


Using  ECSM  (Insertion  Loss 
with  Mfr's  Fixture) 

Using  NIST  1347 

Using  NIST  1347 


NVLAP  1999  DIRECTORY  -  Page  E94 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 

Range  Best  Uncertainty  in  dB  ( ±)note  1  Remarks 
RF  Insertion  Loss 

10  kHz  to  18  GHz  0.4 

ESD  Simulators/Surge  Generators 

0  to  15  kV  ESD  Gun  0.3  dB 

0  to  6  kV  Surge  0.3  dB 


1.     Represents  an  expanded  uncertainty  using  a  coverage  factor,  k=2. 


NVLAP  1999  DD3ECTORY  -  Page  E95 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


COMPAQ  CORPORATE  METROLOGY 

20555  SH  249  (MS  070110) 
P.O.  Box  692000  (MS  070110) 

Houston,  TX  77269-2000 
Contact:  Mr.  David  H.  Shumway 
Phone:  281-514-5787    Fax:  281-518-7275 


Accreditation  Valid  Through:  March  31,  1999 


DC/LOW  FREQUENCY 

NVLAP  Code:  20/E17 
Pulse  Waveform 


NVLAP  LAB  CODE  200154-0 


Parameter 
Risetime  (Generate) 
Risetime  (Measure) 


Range 

<20  ps 

<  1  ns  to  100  ps 


Best  Uncertainty  (±)notel 

14.43% 

5.78% 


Remarks 


Single  Shot 


Impulse  Spectral  Amplitude 
Impulse  Noise  (Source) 
Impulse  Noise  (Source) 
Impulse  Noise  (Source) 


10  kHz  to  150  kHz 
150  kHz  to  30  MHz 
30  MHz  to  1  GHz 


14.21% 
14.21% 
23.43% 


Band  A 
Band  B 
Band  C  &  D 


HV  (Measure) 


1  kV  to  60  kV 
1  kV  to  40  kV 


0.13% 
2.33% 


with  HVD 
with  HV  Probe 


TIME  AND  FREQUENCY 

NVLAP  Code:  20/F03 
Oscillator  Characterization 


Parameter 
Frequency /Period 
Frequency  (Source) 
Frequency  (Measure) 
Frequency  (Comparison) 


Nominal 
10  MHz 

10  MHz,  1  Vrms 
10  MHz,  1  Vrms 


Best  Uncertainty  (±)n 

2.82  x  lO"9 
1.34  x  10 7 
1.34  x  10"9 


Remarks 


1  second 


Duty  Cycle/Duration 
@  1  s  Time  Interval 
@  100  mV  p-p 


10  MHz,  1  Vrms 
2  GHz 


0.61% 
6.24% 


NVLAP  1999  DHtECTORY  -  Page  E96 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Jitter 

@200  mV  p-p 
@  lVrms 


2  GHz 
10  MHz 


1.38% 
1.71% 


Drift 

@  100  s  Time  Interval 


10  MHz 


5.7  x  10'9 


Spectral  Purity 

Single  Sideband  Phase  Noise  (SSB) 

@  +30  to  -20  dBm  10  MHz  to  1300  MHz 

@  0  >  -22  dBm  1  GHz 


15.10% 
15.10% 


with  receiver 

with  spectrum 
analyzer 


Harmonic  Distortion 
@  0  dBm 
@  0  dBm 
@  -22  dBm 


0.2  Hz  to  100  Hz 
1  GHz 

10  Hz  to  100  kHz 


5.44% 

15.10% 

29.91% 


2nd  Order  Harmonic/Intermodulation  Distortion 


@  0  dBm 
@  0  dBm 


0.24  Hz  to  100  Hz 
1  GHz 


5.44% 
15.10% 


AM  Modulation 
AM  (Source) 
AM  (Measure) 
AM  (Source) 


50  Hz  to  50  kHz  Rates  0.18% 
50  Hz  to  50  kHz  Rates  1.41% 
33.33%  of  depth  0.12% 


FM  Modulation 
FM  (Source) 
FM  (Measure) 
FM  (Source) 


DC  to  100  kHz  Rates  0.16% 
50  Hz  to  100  kHz  Rates  1.72% 
34  kHz  Peak  Deviation  0.12% 


PM  Modulation 
PM  (Measure) 


150  kHz  to  1300  MHz 


4.77% 


NVLAP  1999  DIRECTORY  -  Page  E97 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Spurious  Content 

@0dBm  0.2  Hz  to  100  Hz  5.44% 

@0dBm  1  GHz  15.10% 

RF  MICROWAVE 
NVLAP  Code:  20/R13 
Attenuators 

Relative  RF  Power  (Attenuation-Measure) 

Frequency  Nominal  Best  Uncertainty  (±)no'e  12  Remarks 

100  kHz  to  2.6  GHz  0  dB  to  -  20  dB 

100  kHz  to  2.6  GHz  -20  dB  to  -40  dB 

100  kHz  to  2.6  GHz  -40  dB  to  -60  dB 

100  kHz  to  2.6  GHz  -60  dB  to  -80  dB 

100  kHz  to  2.6  GHz  -80  dB  to  -100  dB 

100  kHz  to  2.6  GHz  -100  dB  to  -1 10  dB 

100  kHz  to  2.6  GHz  -1 10  dB  to -120  dB 


M 

+ 

0.02 

dB 

M 

+ 

0.03 

dB 

M 

+ 

0.04 

dB 

M 

+ 

0.05 

dB 

M 

+ 

0.06 

dB 

M 

+ 

0.12 

dB 

M 

+ 

0.17 

dB 

2.5 

GHz 

to 

26 

5 

GHz 

-0  dB  to  - 

10  dB 

2.5 

GHz 

to 

26 

5 

GHz 

-10  dB  to 

-20  dB 

2.5 

GHz 

to 

26 

5 

GHz 

-20  dB  to 

-30  dB 

2.5 

GHz 

to 

26 

5 

GHz 

-30  dB  to 

-40  dB 

2.5 

GHz 

to 

26 

5 

GHz 

-40  dB  to 

-50  dB 

2.5 

GHz 

to 

26 

5 

GHz 

-50  dB  to 

-60  dB 

2.5 

GHz 

to 

26 

5 

GHz 

-60  dB  to 

-70  dB 

2.5 

GHz 

to 

26 

5 

GHz 

-70  dB  to 

-80  dB 

2.5 

GHz 

to 

26 

5 

GHz 

-80  dB  to 

-90  dB 

2.5 

GHz 

to 

26 

5 

GHz 

-90  dB  to 

-100  dB 

2.5 

GHz 

to 

26 

5 

GHz 

-100  dB  to  -110  dB 

2.5 

GHz 

to 

26 

5 

GHz 

-110  dB  to  -120  dB 

30  MHz  0  dB  to  50  dB 

Attenuation  High  Power  (Generate) 
DC  to  2  GHz  20  dB 

DC  to  2  GHz  20  dB 


M 

+ 

0 

22 

dB 

M 

+ 

0 

09 

dB 

M 

+ 

0 

10 

dB 

M 

+ 

0 

13 

dB 

M 

+ 

0 

14 

dB 

M 

+ 

0 

16 

dB 

M 

+ 

0 

18 

dB 

M 

+ 

0 

20 

dB 

M 

+ 

0 

31 

dB 

M 

+ 

0 

32 

dB 

M 

+ 

0 

34 

dB 

M 

+ 

0 

36 

dB 

M 

+ 

0 

07 

dB 

M  +  0.44  dB  with  Narda  766-20 

ATTN. 

M  +  0.80  dB  with  Narda  769-20 

ATTN. 


NVLAP  1999  DmECTORY  -  Page  E98 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Frequency 


Nominal 


Best  Uncertainty  (±)no'el>2 


Remarks 


Attenuation  High  Voltage  (Generate) 


DC  to  1  GHz 
DC  to  2  GHz 


20  dB 
20  dB 


M  +  0.30  dB 
M  +  0.64  dB 


Impedance  (Source) 

DC  to  18  GHz  50  ohms 

DC  to  6  GHz  50  ohms 

DC  to  3  GHz  75  ohms 


1.84% 
0.61% 
0.76% 


Impedance  (Measure) 

300  kHz  to  1  MHz  50  ohms 

1  MHz  to  100  MHz  50  ohms 


12.71% 
8.19% 


100  MHz  to  150  MHz  50  ohms 

100  Hz,  1  kHz,  10  kHz,  50  ohms 
100  kHz 

DC  to  6  GHz  50  ohms 


12.71% 

I.  97% 

II.  79% 


with  LCR  Meter 


(TDR) 


Electrical  Length  (TDR  Measure) 
1  GHz  30  cm 


7.57% 


Return  Loss 

Frequency  Directivity 

0.01  GHz  to  8.4  GHz  >36  dB 

8.4  GHz  to  12.4  GHz  >36  dB 

12.4  GHz  to  18  GHz  >34  dB 


Test  Port  Match 

>23  dB 
>19  dB 
>15  dB 


Best 

Uncertainty  (±)nole  u 
0.16  +  0.071  p"2 
0.16  ±  0.112  pA2 
0.02  +  0.178  p"2 


Insertion  Loss 

Frequency 

300  kHz  to  1  MHz 

1  MHz  to  100  MHz 


Nominal 

>  60  dB  Dynamic 
Range 

>  60  dB  Dynamic 
Range 


Best  Uncertainty  (±)note  1 
13.37% 

9.18% 


Remarks 


NVLAP  1999  DmECTORY  -  Page  E99 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Frequency 

100  MHz  to  300  MHz 
300  MHz  to  1.5  GHz 
1.5  GHz  to  2  GHz 

Phase  (Measure) 
300  kHz  to  1  MHz 
1  MHz  to  100  MHz 
100  MHz  to  300  MHz 
300  MHz  to  1.5  GHz 
1.5  GHz  to  2  GHz 
0.01  Hz  to  160  MHz 

NVLAP  Code:  20/R17 
Power  Meters 

RP  Power  Absolute 
Frequency 
100  kHz  to  18  GHz 
100  kHz  to  18  GHz 
50  MHz  to  26.5  Hz 
10  kHz  to  100  MHz 
100  MHz  to  300  MHz 
300  MHz  to  1  GHz 
1  GHz  to  1.2  GHz 
10  kHz  to  100  MHz 
100  MHz  to  1  GHz 
300  MHz  to  1  GHz 
1  GHz  to  1.2  GHz 
10  kHz  to  100  MHz 
100  MHz  to  300  MHz 
300  MHz  to  1  GHz 
1  GHz  to  1.2  GHz 


Nominal  Best  Uncertainty  (+f»'e  1  Remarks 

>60  dB  Dynamic  13.37% 
Range 

> 60  dB  Dynamic  18.64% 
Range 

> 60  dB  Dynamic  33.93% 
Range 


0  to  360 
0  to  360 
0  to  360 
0  to  360 
0  to  360 
-180  to  2 


degrees 
degrees 
degrees 
degrees 
degrees 
60  degrees 


2.57% 
0.66% 
2.57% 
3.85% 
7.70% 

2.96%  with  Series  Counters 


Nominal  Best  Uncertainty  (±)note  12  Remarks 


+  20  dBm  to  -30  dBm 

M 

+ 

0 

55 

dB 

+  30  dBm  to  -20  dBm 

M 

+ 

0 

25 

dB 

+  30  dBm  to  -20  dBm 

M 

+ 

0 

57 

dB 

0.5  mV 

M 

+ 

0 

20 

dB 

0.5  mV 

M 

+ 

0 

24 

dB 

0.5  mV 

M 

+ 

0 

28 

dB 

0.5  mV 

M 

+ 

0 

43 

dB 

1.0  mV 

M 

+ 

0 

14 

dB 

1.0  mV 

M 

+ 

0 

20 

dB 

1.0  mV 

M 

+ 

0 

24 

dB 

1.0  mV 

M 

+ 

0 

42 

dB 

1.0  mV 

M 

+ 

0 

11 

dB 

10  mV  to  1000  mV 

M 

+ 

0 

11 

dB 

10  mV  to  1000  mV 

M 

+ 

0 

22 

dB 

10  mV  to  1000  mV 

M 

+ 

0 

41 

dB 

NVLAP  1999  DIRECTORY  -  Page  E100 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


Frequency 

Tuned  RF  Power  -  Absolute 
100  kHz  to  2.6  GHz 
100  kHz  to  2.6  GHz 
100  kHz  to  2.6  GHz 
2.5  GHz  to  26.5  GHz 
2.5  GHz  to  26.5  GHz 
2.5  GHz  to  26.5  GHz 
2.5  GHz  to  26.5  GHz 
2.5  GHz  to  26.5  GHz 
2.5  GHz  to  26.5  GHz 
2.5  GHz  to  26.5  GHz 


Nominal 

0  dBm  to  -100  dBm 
-100  dBm  to  -110  dBm 
-110  dBm  to  -120  dBm 
0  dBm  to  -10  dBm 
-10  dBm  to  -40  dBm 
-40  dBm  to  -60  dBm 
-60  dBm  to  -80  dBm 
-80  dBm  to  -90  dBm 
-90  dBm  to  -110  dBm 
-110  dBm  to  120  dBm 


Best  Uncertainty  (±)' 


M 

+ 

0 

28 

dB 

M 

+ 

0 

30 

dB 

M 

+ 

0 

32 

dB 

M 

+ 

0 

64 

dB 

M 

+ 

0 

61 

dB 

M 

+ 

0 

62 

dB 

M 

+ 

0 

63 

dB 

M 

+ 

0 

67 

dB 

M 

+ 

0 

68 

dB 

M 

+ 

0 

69 

dB 

1.  Represents  an  expanded  uncertainty  using  a  coverage  factor,  k=2. 

2.  M  =  Mismatch  uncertainty 

3.  Derived  Return  Loss  uncertainty  statements  in  'p'  (Reflective  Coefficient). 


NVLAP  1999  DffiECTORY  -  Page  E101 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  200211-0 

ILX  LIGHTWAVE  CORPORATION,  OPTICAL  CALIBRATION 

31950  E.  Frontage  Road 
P.O.  Box  6310 
Bozeman,  MT  59715 
Contact:  Mr.  Sergey  Siny 
Phone:  406-586-1244  x118    Fax:  406-586-9405 
E-Mail:  ssiny@ilxlightwave.com 

Accreditation  Valid  Through:  December  31,  1999 

OPTICAL  RADIATION 

NVLAP  Code:  20/O01 
Laser  Power  Energy 

Range 

Optical  Fiber  Power  Meters  in  A/W 

1011  A  to  10"3  A,  1  pW  to  2  mW 


NVLAP  Code:  20/003 
Radiometric 

Photodiode  Spectral  Response  in  A/W 

10"  A  to  103  A,  1  pW  to  2  mW  400  to  1700  nm  1.42  to  3.15 


1.  Represents  an  expanded  uncertainty  using  a  coverage  factor,  k=2. 

2.  Uncertainty  varies  with  wavelength. 


Wavelength  Best  Uncertainty  (±)  in  %" 


800  to  1700  nm  2.31  to  3.15 


NVLAP  1999  DIRECTORY  -  Page  E102 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  200235-0 

STERIS-ISOMEDIX  SERVICES 

11  Apollo  Drive 
Whippany,  NJ  07981 
Contact:  Mr.  Glenn  W.  Calvert 
Phone:  973-887-4700    Fax:  973-887-1476 
E-Mail:  isomedix@nac.net 

Accreditation  Valid  Through:  December  31,  1999 

IONIZING  RADIATION 

NVLAP  Code:  20/102 
High  Dose  Dosimetry 

Source  Range  Best  Uncertainty (±)"°'el 

60  Co  Gamma  Rays  100  grays  or  more  at  a  rate  of  approximately  2.5% 

1  to  20  kgy/hour 


1.     Represents  an  expanded  uncertainty  using  a  coverage  factor,  k=2. 


NVLAP  1999  DIRECTORY  -  Page  E103 


(See  'How  To  Use  This  Directory'  on  page  7.) 


INDEX  E.  LISTING  OF  CALIBRATION  LABORATORIES  BY  NVLAP  LAB  CODE  -  continued 


NVLAP  LAB  CODE  200262-0 

METROPLEX  METROLOGY  LAB,  INC. 

2309  E.  Loop  820  North 
Fort  Worth,  TX  76118-7103 
Contact:  Mr.  James  L.  Johnson 
Phone:  817-589-8300   Fax:  817-589-8311 

Accreditation  Valid  Through:  March  31,  1999 

DIMENSIONAL 

NVLAP  Code:  20/D03 
Gage  Blocks 

Range 
0  to  1  in 
>  1  in  to  4  in 


Best  Uncertainty  (±)no,e  1  Remarks 
2.5  /iin 

2.5  ^in  +  0.5  uin/in 


NVLAP  Code:  20/D14 
Threaded  Plug  and  Ring  Gages 

Plug  Gages  0  to  6  in  70.3  ^tin  Major  Diameter 

Ring  Gages  0  to  6  in  196.1 /tin  Major  Diameter 


1.     Represents  an  expanded  uncertainty  using  a  coverage  factor,  k-2. 


■0  U.  S.  GOVERNMENT  PRINTING  OFFICE:  1999-454-531/17101 


NVLAP  1999  DIRECTORY  -  Page  E104 


(See  'How  To  Use  This  Directory'  on  page  7.) 


Technical  Publications 


Periodical 


Journal  of  Research  of  the  National  Institute  of  Standards  and  Technology — Reports  NIST  research 
and  development  in  those  disciplines  of  the  physical  and  engineering  sciences  in  which  the  Institute  is 
active.  These  include  physics,  chemistry,  engineering,  mathematics,  and  computer  sciences.  Papers  cover  a 
broad  range  of  subjects,  with  major  emphasis  on  measurement  methodology  and  the  basic  technology 
underlying  standardization.  Also  included  from  time  to  time  are  survey  articles  on  topics  closely  related  to 
the  Institute's  technical  and  scientific  programs.  Issued  six  times  a  year. 


Nonperiodicals 


Monographs — Major  contributions  to  the  technical  literature  on  various  subjects  related  to  the 
Institute's  scientific  and  technical  activities. 

Handbooks — Recommended  codes  of  engineering  and  industrial  practice  (including  safety  codes)  devel- 
oped in  cooperation  with  interested  industries,  professional  organizations,  and  regulatory  bodies. 
Special  Publications — Include  proceedings  of  conferences  sponsored  by  NIST,  NIST  annual  reports,  and 
other  special  publications  appropriate  to  this  grouping  such  as  wall  charts,  pocket  cards,  and  bibliographies. 

National  Standard  Reference  Data  Series — Provides  quantitative  data  on  the  physical  and  chemical 
properties  of  materials,  compiled  from  the  world's  literature  and  critically  evaluated.  Developed  under  a 
worldwide  program  coordinated  by  NIST  under  the  authority  of  the  National  Standard  Data  Act  (Public 
Law  90-396).  NOTE:  The  Journal  of  Physical  and  Chemical  Reference  Data  (JPCRD)  is  published 
bimonthly  for  NIST  by  the  American  Chemical  Society  (ACS)  and  the  American  Institute  of  Physics  (AIP). 
Subscriptions,  reprints,  and  supplements  are  available  from  ACS,  1155  Sixteenth  St.,  NW,  Washington,  DC 
20056. 

Building  Science  Series — Disseminates  technical  information  developed  at  the  Institute  on  building 
materials,  components,  systems,  and  whole  structures.  The  series  presents  research  results,  test  methods,  and 
performance  criteria  related  to  the  structural  and  environmental  functions  and  the  durability  and  safety 
characteristics  of  building  elements  and  systems. 

Technical  Notes — Studies  or  reports  which  are  complete  in  themselves  but  restrictive  in  their  treatment  of 
a  subject.  Analogous  to  monographs  but  not  so  comprehensive  in  scope  or  definitive  in  treatment  of  the 
subject  area.  Often  serve  as  a  vehicle  for  final  reports  of  work  performed  at  NIST  under  the  sponsorship  of 
other  government  agencies. 

Voluntary  Product  Standards — Developed  under  procedures  published  by  the  Department  of  Commerce 
in  Part  10,  Title  15,  of  the  Code  of  Federal  Regulations.  The  standards  establish  nationally  recognized 
requirements  for  products,  and  provide  all  concerned  interests  with  a  basis  for  common  understanding  of 
the  characteristics  of  the  products.  NIST  administers  this  program  in  support  of  the  efforts  of  private-sector 
standardizing  organizations. 

Order  the  following  NIST  publications — FIPS  and  NISTIRs—from  the  National  Technical  Information 
Service,  Springfield,  VA  22161. 

Federal  Information  Processing  Standards  Publications  (FIPS  PUB) — Publications  in  this  series 
collectively  constitute  the  Federal  Information  Processing  Standards  Register.  The  Register  serves  as  the 
official  source  of  information  in  the  Federal  Government  regarding  standards  issued  by  NIST  pursuant  to 
the  Federal  Property  and  Administrative  Services  Act  of  1949  as  amended,  Public  Law  89-306  (79  Stat. 
1127),  and  as  implemented  by  Executive  Order  11717  (38  FR  12315,  dated  May  11,  1973)  and  Part  6  of 
Title  15  CFR  (Code  of  Federal  Regulations). 

NIST  Interagency  or  Internal  Reports  (NISTIR) — The  series  includes  interim  or  final  reports  on  work 
performed  by  NIST  for  outside  sponsors  (both  government  and  nongovernment).  In  general,  initial 
distribution  is  handled  by  the  sponsor;  public  distribution  is  handled  by  sales  through  the  National  Technical 
Information  Service,  Springfield,  VA  22161,  in  hard  copy,  electronic  media,  or  microfiche  form.  NISTIR 's 
may  also  report  results  of  NIST  projects  of  transitory  or  limited  interest,  including  those  that  will  be 
published  subsequently  in  more  comprehensive  form. 


CL 
< 


2 

!XJ 


< 
CC 

O 
O 
cc 

CL 

Z 

o 
h- 
< 

H 

Q 


1  CC 

Q  U 

Z  (J 

<  < 


O 

o 


co  < 


h- 


!-  Z 


Q  < 

i.u  Z 

w  < 

D  Z 


O 


CQ  CN  O) 


Q_ 

~*  O 

>  \— 
CC  CO 
< 


CD 
00 

o 


< 
Z 

g  _ 

<  o 
z  <- 


u  DC 

<  DO 

uJ  CO 

cc  cc 


< 


o 
o 

00 
v> 

UJ 

CO 

D 

UJ 

I- 

cog 

CO  — 
UJ  CC 

2  Q. 

CO  CC 

3  O 
CQ  U- 

_!  > 
<  h- 

«3 

u-  Z 

UL  yj 

O  a. 


a 

UJ 

h- 

UJ 

=1 

d 

UJ 

CC 

LU 

o 
> 

a 

UJ 

CO 

to 
CO 
UJ 
CC 
Q 
D 
<